Loading...
APPROVED BLD BLD2024-1225+Architectural_Plan+9.18.2024_9.02.34_AM+4507571ELEVATION 3 /Ej\ MAIN FLOOR PLAN SCALE 1/4" = 1' � HARDWARE &FASTENERS IN CONTACT WITH PRESERVATIVE -TREATED � � WOOD SHALL BE OF HOT -DIPPED ZINC GALVANIZED STEEL, STAINLESS � STEEL, SILICON BRONZE OR COPPER. IN THE ABSENCE OF � MANUFACTURER'S RECOMMENDATIONS AMINIMUM OF ASTM A 653 TYPE � G185 ZINC -COATED GALVANIZED STEEL, OR EQUIVALENT, SHALL BE USED. � IRC R317.3.1 IBC 2304.10.5.1 � ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE City Of Edmonds Building Department Work REBUILD DECK ------------------------- Address 8925 200TH ST SW ------------------------------------------------ Owner KITCHNER Approved Date 09/23/2024 Building Official Permit Number BLD2024-1225 RECEIVED Sep 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 2021 I RG SECTION R501.3.2 z O I—a �IL tx LU LU V Z� vLU LU�Q Q _J trl t� } LUz o kD o � > LU 0 Q a Q 0 z DATE: 9/18/2024 SCALE: SHEET: P-1 0-1 LU 16' 6'-11 " 6'-11"� DECK FRAMING: 16" VIA. CONCRETE FOOTING5 24" DEEP 0646 P05T BASE EMBEDED INTO CONCRETE FOOTING 4 X 6 PT P05T TO OC66 TO 4 X 12 PT BEAM 2 X 10 PT J015T @ 1 F 0/0 TYP. 2 X 10 PT LEDGER @ HOU5E FLA51-1ING UNDER 5101NG / OVER LEDGER DECK FRAMING PLAN SCALE 1/4 11 = 1' EAST ELEVATION SGALE 1 /4" = 1' RECEIVED Sep 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT z O H a Lu w} J co � Lu � Ow Lu a 0 Lu z v� as IL tx Lu Lu t� Z� �v vLu Lu�Q Q trl } Lu co z o kD o � > LuClClz � Q z 0 DATE: 9/18/2024 SCALE: SHEET: P-2 �MyBui ldi ngPermit.com a service of eCityGov.net Construction Tip Sheet 05 Basic Deck This tip sheet reflects code requirements of the 2018 International Residential Code (IRC) with Washington State Amendments. Typical Deck This document provides building code information applicable to prescriptive residential wood deck design. You may need to hire a licensed architect or engineer to design a deck where any of the following conditions apply: • The deck serves other than a one- or two-family dwelling building • The deck design includes more than one level • The deck will support a hot tub, spa or other heavy object, including heavy deck covering (such as pavers) • The walking surface is more than 14 feet above grade • The deck ledger is attached to house overhangs, bay windows, bricks, stone, or concrete block • The deck is bearing on ground with a slope greater than 1 foot horizontal for every 1 foot vertical • The deck is self-supporting (not attached to an exterior wall) Ledger See oew+ t for ledger connection opaom. Joi Decking Verify span ratings of proposed docking Joist Overhang 24' maximum Joist Spacing moo span table and tooting schedule. Post 4x4 min up to 8' 0' height 5x6 minup to 10' 0* height Non -corrosive metal post/beam connector Continuous solid blocking between joists Beam Overhang 24" maximum January 14, 2022 Note: Guards are required when the deck walking surface is more than 30" above grade. MyBuildingPerm it.com i Basic Deck �MyBui ldi ngPermit.com a service of eCityGov.net eCityGay.net 2005 eriNcc . 'l our,- Construction Tip Sheet 05 When using the tables below, interpolation is allowed, extrapolation is not allowed. Sizing of Structural Elements Maximum Deck Joist Span a,c Joist Spacing b Joist inches Joist Back Span Size 12 1 16 1 24 4 6 1 8 1 10 12 14 1 16 18 Allowable Joist Span Maximum Cantilever (feet inches Adjacent Joist Span feet 2x6 7-11 7-1 1 5-9 1-0 1-6 NP NP NP NP NP NP 2x8 10-5 7-8 1-0 1-6 2-0 NP NP NP NP 2x 10 13-3 11-6 9-5 1-0 1-6 2-0 2-6 2-8 NP NP NP 2x 12 15-5 74 10-11 1-0 1-6 2-0 - 3-0 3-3 NP NP a. Includes Incising Factor. b. When using composite decking, refer to manufacturer's installation instructions for maximum spacing of joists. c. Spans based on Doug Fir -Larch, Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service factor. Minimum Beam Size Deck Joist Span feet 6 8 10 12 1 14 1 16 18 Beam Maximum Beam Span a,b,d (feet -inches) Size c,d,e 4x6 5-2 4-6 4-0 3-5 3-1 2-10 2-7 4x8 6-11 6-0 5-3 4-7 4-1 3-8 3-5 4x10 8-5 7-4 6-6 5-2 4-9 4-5 4x12 9-10 8-6 7-7 6-11 6-4 5-9 5-4 6x6 6-6 5-7 5-0 4-7 4-2 3-9 3-5 6x8 8-8 7-6 6-8 6-1 5-6 5-0 4-7 6x10 10-7 9-2 8-2 7-6 6-11 6-4 5-10 6x12 1 12-4 10-8 9-7 8-9 8-1 1 7-7 1 7-1 a. Spans based on Doug Fir -Larch, Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service factor. b. If 2x built up beams to make 4x or 6x beams, they shall be fastened with two rows of 10d (3-inch x 0.128-inch) nails minimum at 16 inches on center along each edge (507.5) c. Beam depth shall be equal to or greater than the depth of intersecting joist for a flush beam connection. d. Beam cantilevers are limited to the adjacent beam's span divided by 4. e. Includes incising factor. January 14, 2022 MyBuildingPermit.com I Basic Deck eCityGov.net 2005 & eUyGoyhliance 9R - 1 ST FLOOR 9R - FOUNDATION .2' STING RECEIVED Sep 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT a. Includes Incising Factor. b. When using composite decking, refer to manufacturer's installation instructions for maximum spacing of joists. c. Spans based on Doug Fir -Larch, Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service factor. Minimum Beam Size Deck Joist Span feet 6 8 10 12 1 14 1 16 18 Beam Maximum Beam Span a,b,d (feet -inches) Size c,d,e 4x6 5-2 4-6 4-0 3-5 3-1 2-10 2-7 4x8 6-11 6-0 5-3 4-7 4-1 3-8 3-5 4x10 8-5 7-4 6-6 5-2 4-9 4-5 4x12 9-10 8-6 7-7 6-11 6-4 5-9 5-4 6x6 6-6 5-7 5-0 4-7 4-2 3-9 3-5 6x8 8-8 7-6 6-8 6-1 5-6 5-0 4-7 6x10 10-7 9-2 8-2 7-6 6-11 6-4 5-10 6x12 1 12-4 10-8 9-7 8-9 8-1 1 7-7 1 7-1 a. Spans based on Doug Fir -Larch, Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service factor. b. If 2x built up beams to make 4x or 6x beams, they shall be fastened with two rows of 10d (3-inch x 0.128-inch) nails minimum at 16 inches on center along each edge (507.5) c. Beam depth shall be equal to or greater than the depth of intersecting joist for a flush beam connection. d. Beam cantilevers are limited to the adjacent beam's span divided by 4. e. Includes incising factor. January 14, 2022 MyBuildingPermit.com I Basic Deck eCityGov.net 2005 & eUyGoyhliance 9R - 1 ST FLOOR 9R - FOUNDATION .2' STING RECEIVED Sep 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT a. Spans based on Doug Fir -Larch, Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service factor. b. If 2x built up beams to make 4x or 6x beams, they shall be fastened with two rows of 10d (3-inch x 0.128-inch) nails minimum at 16 inches on center along each edge (507.5) c. Beam depth shall be equal to or greater than the depth of intersecting joist for a flush beam connection. d. Beam cantilevers are limited to the adjacent beam's span divided by 4. e. Includes incising factor. January 14, 2022 MyBuildingPermit.com I Basic Deck eCityGov.net 2005 & eUyGoyhliance 9R - 1 ST FLOOR 9R - FOUNDATION .2' STING RECEIVED Sep 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT z O i= a w 0 w} J co � �w z� Ow w w a 0 w m z 0-1 CO i N i� �IL !.L NNl U LU lL Z %J LU W Q Q _J trl } LU z kD o � W � 0 Q a Q z � Q z 0 DATE: 9/ 18/2024 SCALE: SHEET: P-3 �MyBui ldi ngPermit.com a service of eCityGov.net Construction Tip Sheet 05 �MyBui ldi ngPermit.com a service of eCityGov.net Construction Tip Sheet 05 Maximum Deck Post Height Tributalry Area e Post 20 40 60 80 1 100 1 120 140 160 Size c,d Maximum Deck Post Height a feet -inches 4x4 10-0 10-0 8-7 7-0 5-8 4-1 N P N P 4x6 14-0 13-10 11-1 9-5 8-2 7-3 6-4 5-4 6x6 14-0 14-0 14-0 14-0 14-0 13-3 10-9 6-11 8x8 14-0 14-0 14-0 14-0 14-0 14-0 14-0 14-0 a. Measured from the underside of the beam to top of footing. b. Based on Doug Fir, Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service factor. c. Notched deck posts shall be sized to accommodate beam size. d. Includes incising factor. e. Area, in square feet, of deck surface supported by post and footing. Footing Size a Tributary Area b Side of Square Footing (inches) Diameter of a Round Footing inches Thickness (inches) 5 7 6 20 12 (124 6 40 186 60 21 24 8 80 25 28 9 100 28 31 11 120 30 34 12 140 33 37 160 35 40 15 a. Footing dimensions shall allow complete bearing of the post. b. Area, in square feet, of deck surface supported by post and footings. In a, , frost depth wable soils Manufactured post connector Typical P.T. post In al � � 12" Grade f 1 -1 III-1 -1I • I_I-1 I-1 ,I I I-111-1I I • RII Thickness per Table < Note: Posts must be Width 1/2" diameter centered on or in footingper through -bolts In both Table directions 4" gravel Min. 12" of Note: not screws embedment January 14, 2022 MyBuildingPermit.com I Basic Deck eCityGov.net 2005,E eCICyGaOhance �MyBui ldi ngPermit.com a service of eCityGov.net Construction Tip Sheet 05 EXTERIOR SHEATHING EXISTING STUD WALL Existing 2x BAND JOIST OR ENGINEERING RIM BOARD DECK JOIST SCREWS OR BOLTS JOIST HANGER Lag screw or bolt Stagger fasteners in 2 rows 2" min. � 5 1/2" min. for 2x8 6 112" min. for 2x10 5 m 7 112" min. for 2x12 �J 3/4" min. "2" Ledger " Distance can be reduced to min. 4 112" if lag screws are used or Minimum edge distance for if bolt spacing is reduced to specialized screws. See that of lag screws to attach 2x8 manufacturer's technical bulletin. ledgers to 2x8 band joists Detail 1 — Ledger Attachment for Lateral Loads (Knee braces are require is greater tha 4 feet in height Hold-down or Sheathing tension device Siding with 1500 z capacity Floorsheathin nailing Flashing at 6' o.c. (max) fast with hold-down. Decking Flashing Joists Joist Hangers ,l s Treated 2x ledger Deck Joist Floor fas 750# capacity holddown device at 4 locations evenly distrilwted along the deck and within 2 ft of each end. Install per manufacturer January 14, 2022 Option # 1 T threaded 3/8" diameter lag screw) p predrilled with a minimum of 3 in Option # 2 MyBuildingPermit.com I Basic Deck 2' min. Floor joists ecityGov.net 2005 -�. a0ryGovNlianca Deck Ledger and Connections Deck Ledger Connection to Band Joist On -Center Spacing of Fasteners inches Joist Span c (feet) 1/2-inch diameter lag screw with 1/2-inch maximum sheathing b,c,e 1/2-inch diameter bolt with 1/2-inch maximum sheat ling c 1/2-inch diameter bolt screw with 1-inch maximum sheathing d 6 22 36 35 8 16 31 26 10 13 25 21 1 in 20 17 17 15 16 8 15 13 18 7 13 11 a. Ledgers shall be flashed in accordance with Section R703.4 to prevent water from contacting the house band joist. b. The tip of the lag screw shall fully extend beyond the inside face of the band joist. c. Sheathing shall be wood structural panel or solid sawn lumber. d. Sheathing shall be permitted to be wood structural panel, gypsum board, fiberboard, lumber, or foam sheathing. Up to 1/2-inch thickness of stacked washers shall be permitted to substitute for up to 1/2-inch of allowable sheathing thickness where combined with wood structural panel or lumber sheathing. e. For on -center spacing of specialized fasteners refer to the manufacturer's installation instructions. Placement of Lag Screws and Bolts in Ledgers and Band Joists Minimum End and Edge Distance and Spacing Between Rows Top Edge Bottom Edge Ends Row Spacing Ledger a 2 inches 1 3/4 inch 2 inches 1 1-5/8 inches Band joist ` 3/4 inch 2 inches e 2 inches b 1-5/8 inches b a. Lag screws or bolts must be staggered from the top and bottom along the horizontal run. See figure below. b. Maximum 5 inches. c. For engineered rim joists, the manufacturer's recommendations govern. d. The minimum distance from the bottom row to the top edge of the ledger must be in accordance with figure below. e. 2 inches may be reduced to 3/4-inch when the band joist is directly supported by a mudsill, header, or by double top wall plates. January 14, 2022 MyBuildingPermit.com I Basic Deck 2705 � eCihC�.:ull�ance MyBuildingPermit.com a service of eCityGov.net Construction Tip Sheet 05 Guards & Attachment GUARDS SHALL NOT HAVE AN OPENING FROM THE WALKING SURFACE Guards are required when the deck is more than 30 inches above grade.) ; TO THE REQUIRED GUARD HEIGHT THAT WILL ALLOW THE PASSAGE OF A4" SPHERE IN ACCORDANCE WITH 2O21 IRC R312.1.3. 2x2 Baluster, typical 6-0" max. spacing 2x6 or 5/4 board ail cap: attach to guard post with (3) #12 by 3" long screws or (3) 16d threaded nails with 0.148 nominal diameter 2x4 top and bottom; attach to guard post with (2) 8d threaded nails or (2) #8 wood Screws 2 1/2" long On inside face 4x4 guard post, typical Do Not Notch 2 x 8 nominal rim or outside joist, minimum 2 5/8" diameter Openings shall Attach balusters at top and bottom with through -bolts not allow the (1) #8 wood screw or (2) 8d post -frame and washers passage of a 4" threaded nails with 0.135 nominal diameter sphere diameter max A 4x4 min. post %" O.D. galvanized bolt @ 60" o.c. max., Typ or threaded rod w/ nuts & washers 2 min 0 0 4' min and 5" maxf 2x8 min. deck joists & rims Min. 1800# tension device 1/8" O.D. galvanized bolt or threaded rod w/ nuts & washers 2)" min anc Section A 2x8 min. blocking 2"min Use above details for guard connections or provide engineered Min. 1800# tension straps y design that shows Guards can resist a single concentrated load of 200 Ibs applied in any direction at any point along the top and Section B have attachment devices and supporting structure to transfer this load to appropriate structural elements of the building per IBC sec 1607.7.1.1 January 14, 2022 MyBuildingPermit.com I Basic Deck ecityGov.net 2005 aCllyGowMiance RECEIVED Sep 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT z O w 0 w� J m� m �w z� Ow w w Q 0 w m z v� M� WU LU W Z vLU W Y Q _J } W z w 0 0 � > LU 0 Q a Q CJ � z � Q z 0 DATE: 9/18/2024 SCALE: SHEET: F-4