Loading...
REV1 APPROVED PLN BLD BLD2024-1225+Architectural_Plan+10.14.2024_9.22.35_AM+4557180ELEVATION 3 E;_i MAIM FLOOR PLAN 56ALE 1 /411 = 1' APPROVED BY PLANNING Oct 1 E` 2024 REVISIONS REV1 10/15/2024 ADDED ROOF COVERING OVER REBUILT DECK REV2 REV3 REW REV5 HARDWARE & FASTENERS IN CONTACT WITH PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. IN THE ABSENCE OF MANUFACTURER'S RECOMMENDATIONS A MINIMUM OF ASTM A 653 TYPE G185 ZINC -COATED GALVANIZED STEEL, OR EQUIVALENT, SHALL BE USED. IRC R317.3.1 IBC 2304.10.5.1 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE REVISED PLAN APPROVED CITY OF EDMONDS BUI DING DIVISION BUILDING OF ICIAL Oct 15 2024 APPROVED DATE BLD2024-1225 REVISION Oct 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 2021 IRO 5 E OT I O N R50"1. 3.2 Z O W 0 W � J CID Q Q W Z � Ow w w Q 0 w m z v� i� Lu Lu V Z T uu W �Q a trl m w z o kD 0 � > w ° Ca a Q C�7 � z Q z 0 DATE: 10/14/2024 SCALE: SHEET: P-1 iry DECK FRAMING: 24" X 24" 5QUARE CONCRETE FOOTING5 24" DEEP BELOW GRADE GB66 P05T BA5E EMBEDED INTO CONCRETE FOOTING 6 X 6 PT P05T 5 TO RUN THROUGH DECK FRAMING TO 6 X 12 PT BEAM 6 X 12 PT BEAM TO BE CARRIED BY 6 X 12 GALV HANGER / REVER5E FLANGE 2 X 10 PT J015T @ 12" O/C, TYP. 2 X 10 PT LEDGER @ HOUSE FLA5HIN6 UNDER 510IN6 / OVER LEDGER DECK FRAMING PLAN SCALE 1/4" = 1' EAST ELEVATION SCALE 1 /4" = 1' BLD2024-1225 REVISION Oct 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT z 0 w w 0 w} J v� a� IL L uu Z� v uu W �Q Q f�] m lU w 0 > W o0C A a Q (D z Q z 0 DATE: 10/14/2024 SCALE: SHEET: P-2 CoOf �MyBui [di ngPermit.com a service of eCityGov.net Construction Tip Sheet 05 Basic Deck This tip sheet reflects code requirements of the 2018 International Residential Code (IRC) with Washington State Amendments. Typical Deck This document provides building code information applicable to prescriptive residential wood deck design. You may need to hire a licensed architect or engineer to design a deck where any of the following conditions apply: • The deck serves other than a one- or two-family dwelling building • The deck design includes more than one level • The deck will support a hot tub, spa or other heavy object, including heavy deck covering (such as pavers) • The walking surface is more than 14 feet above grade • The deck ledger is attached to house overhangs, bay windows, bricks, stone, or concrete block • The deck is bearing on ground with a slope greater than 1 foot horizontal for every 1 foot vertical • The deck is self-supporting (not attached to an exterior wall) J Decking Venty span ratings of proposed docking. Joist Overhang 24' maximum Ledger See Detail 1 for ledger connection options. Joist Hanger Joist Spacing F '� See span table and ` J tooling schedule. P / T, Post 4x4 min up to 8'-0' height 34 mm, up to 10'-0' height Non -corrosive metal post/beam connector Continuous solid blocking between joists Beam Overhang 24" maximum January 14, 2022 See Page 6 '<<for Ledger ��Attachment f Joist Span S" span table i Beam Note: Guards are See span table required when the deck walking surface is more Footing than 30" above fade. See span table and g rooting schedule. MyBuildingPermit.com I Basic Deck �MyBui ldi ngPermit.com a service of eCityGov.net e0tyGov.net 2005 � eCIIVI O lliance Construction Tip Sheet 05 When using the tables below, interpolation is allowed, extrapolation is not allowed. Sizing of Structural Elements Maximum Deck Joist Span a,c Joist Joist Spacing b inches Joist Back Span Size 12 1 16 1 24 4 6 8 10 1 12 14 16 18 Allowable Joist Span Maximum Cantilever feet -inches Adjacent Joist Span feet 2x6 7-11 7-1 5-9 1-0 1-6 NP NP NP NP NP NP 2x8 9-5 7-8 1-0 1-6 2-0 NP NP NP NP 2x10 13-3 1-6 9-5 1-0 1-6 2-0 2-6 2-8 NP NP NP 2x12 1 -5 13-4 10-11 1-0 1-6 2-0 - 3-0 3-3 NP NP a. Includes Incising Factor. b. When using composite decking, refer to manufacturer's installation instructions for maximum spacing of joists. c. Spans based on Doug Fir -Larch, Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service factor. Minimum Beam Size Deck Joist Span feet 6 8 10 12 1 14 16 18 Beam Size c,d,e Maximum Beam Span a,b,d (feet -inches) 4x6 5-2 4-6 4-0 3-5 3-1 2-10 2-7 4x8 6-11 6-0 5-3 4-7 4-1 3-8 3-5 4x10 8-5 7-4 6-6 5-10 5-2 4-9 4-5 4x12 9-10 8-6 7-7 6-11 6-4 5-9 5-4 6x6 6-6 5-7 5-0 4-7 1 4-2 3-9 3-5 6x8 8-8 7-6 6-8 6-1 5-6 5-0 4-7 6x10 10-7 9-2 8-2 6-11 6-4 5-10 6x12 12-4 10-8 9-7 8-9 8-1 7-7 7-1 a. Spans based on Doug Fir -Larch, Hem Fir and-Spfuce-Pine-Fir, No. 2 grade, wet service factor. b. If 2x built up beams to make 4x or 6x beams, they shall be fastened with two rows of 10d (3-inch x 0.128-inch) nails minimum at 16 inches on center along each edge (507.5) c. Beam depth shall be equal to or greater than the depth of intersecting joist for a flush beam connection. d. Beam cantilevers are limited to the adjacent beam's span divided by 4. e. Includes incising factor. January 14, 2022 MyBuildingPermit.com I Basic Deck KityGov.net 2005,E eCltvG hlienca GOVER FRAMING PLAN SCALE 1/411 = 1' V DEVELOPMENT SERVICES DEPARTMENT z O w w 0 w} J m m � �w z� O> � w w w Q 0 w In Z V �IL l� LN LU !� Z Tv v uU W Q Q _J CO } LU z LU o > W 0 Q a Q z � Q z 0 DATE: 10/14/2024 SCALE: SHEET: �-3 �MyBui ldi ngPermit.com a service of eCityGov.net Construction Tip Sheet 05 Maximum Deck Post Height Tributalry Area e Post 20 40 60 1 80 100 120 140 160 Size c,d Maximum Deck Post Height a feet -inches 4x4 10-0 10-0 8-7 7-0 5-8 4-1 N P N P 4x6 1 14-0 13-10 11-1 9-5 8-2 7-3 6-4 5-4 6x6 14-0 14-0 14-0 14-0 14-0 13-3 10-9 6-11 8x8 14-0 14-0 14-0 14-0 14-0 14-0 14-0 14-0 a. Measured from the underside of the beam to top of footing. b. Based on Doug Fir, Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service factor. c. Notched deck posts shall be sized to accommodate beam size. d. Includes incising factor. e. Area, in square feet, of deck surface supported by post and footing. Footing Size a Tributary Area b Side of Square Footing (inches) Diameter of a Round Footing inches Thickness (inches) 5 7 8 6 20 12 14 6 40 18 20 6 60 24 8 80 25 28 9 100 31 11 120 30 34 12 140 33 37 fQ- 160 35 40 1 15 a. Footing dimensions shall allow complete bearing of the post. b. Area, in square feet, of deck surface supported by post and footings. —V V 1 " min. frost depth Manufactured post connector Typical P.T. post in al wabie soils /_ 12" Grade1. t1 -1II 1. II1-1 -1II II1-III-1II °�-1II-1II III -III -III II1-1I1-1II I1-1_I a Thickness ; per Table Note: Posts must be width 1/2" diameter centered on or in footing per through -bolts in both 4" gravel Min. 11 of g Table directions Note: not screws embedment January 14, 2022 MyBuildingPermit.com I Basic Deck eCityGov.net 2005 2. aClryGavAJliance �MyBui ldi ngPermit.com a service of eCityGov.net Construction Tip Sheet 05 EXTERIOR SHEATHING EXISTING STUD WALL Existing 2x BAND JOIST OR ENGINEERING RIM BOARD Lag screw or bolt 2" min. 5" max. "2" min. Minimum edge distance for specialized screws- See manufacturer's technical bulletin. Hold-down or tension device with 1500 # capacity Flashing Deck Joist January 14, 2022 DECK JOIST SCREWS OR BOLTS JOIST HANGER Stagger fasteners in 2 rows 5 112" min. for 2x8 6 112" min. for 2x10 7 112" min. for 2x 12 3/4" min. Ledger " Distance can be reduced to 4 112" if lag screws are used or if bolt spacing is reduced to that of lag screws to attach 2x8 ledgers to 2x8 band joists Detail 1 — Ledaer Attachment for Lateral Loads (Knee braces are require is greater than 4 feet in height Sheathing Siding Fborsheathin nailing Flashing at 6" o.c. (max) joist with hold-down. Decking Joists Joist Hangers Treated 2x ledger Option # 1 Floorpks 750# capacity holddown device at 4 locations evenly distributed along the deck and within 2 It of each end. Install per manufacturer threaded 3/8" diameter lag screw predrilled with a minimum of 3 in MyBuildingPermit.com I Basic Deck J Option # 2 2" min. Floor joists eCityGovnet M05 ,�. aCII&YAlliance �MyBui ldi ngPermit.com a service of eCityGov.net Deck Ledger and Connections Construction Tip Sheet 05 Deck Ledger Connection to Band Joist On -Center Spacing of Fasteners inches Joist Span D (feet) '/2-inch diameter lag screw with 1/2-inch maximum sheathin b,c,e '/2-inch diameter bolt with'/2-inch maximum sheathing c '/2-inch diameter bolt screw with 1-inch maximum sheathing d 6 22 36 35 8 16 31 26 10 13 25 21 1 1 20 17 17 15 16 8 15 13 18 7 13 11 a. Ledgers shall be flashed in accordance with Section R703.4 to prevent water from contacting the house band joist. b. The tip of the lag screw shall fully extend beyond the inside face of the band joist. c. Sheathing shall be wood structural panel or solid sawn lumber. d. Sheathing shall be permitted to be wood structural panel, gypsum board, fiberboard, lumber, or foam sheathing. Up to 1/2-inch thickness of stacked washers shall be permitted to substitute for up to 1/2-inch of allowable sheathing thickness where combined with wood structural panel or lumber sheathing. e. For on -center spacing of specialized fasteners refer to the manufacturer's installation instructions. Placement of Lag Screws and Bolts in Ledgers and Band Joists Minimum End and Edge Distance and Spacing Between Rows Top Edge Bottom Edge Ends Row Spacing Ledger a 2 inches 3/4 inch 1 1 2 inches 1 1-5/8 inches Band joist ` 3/4 inch 2 inches e 2 inches b 1-5/8 inches b a. Lag screws or bolts must be staggered from the top and bottom along the horizontal run. See figure below. b. Maximum 5 inches. c. For engineered rim joists, the manufacturer's recommendations govern. d. The minimum distance from the bottom row to the top edge of the ledger must be in accordance with figure below. e. 2 inches may be reduced to 3/4-inch when the band joist is directly supported by a mudsill, header, or by double top wall plates. January 14, 2022 MyBuildingPermit.com I Basic Deck eCityGov.net 2005 �� eCltyGovAllianca �MyBui ldi ngPermit.com a service of eCityGov.net Construction Tip Sheet 05 Guards & Attachment Guards are required when the deck is more than 30 inches above grade.) through -bolts not allow the and washers passage of a 4" diameter sphere 16 max A 2x2 Baluster, typical 2x6 or 5/4 board ail cap: attach to guard post with (3) #12 by 3" long screws or (3) 16d threaded nails with 0.148 nominal diameter 2x4 top and bottom; attach to guard post with (2) 8d threaded nails or (2) #8 wood screws 2 1/2" long on inside face 4x4 guard post, typical Do Not Notch 2 x 8 nominal rim or outside joist, minimum Attach balusters at top and bottom with (1) #8 wood screw or (2) 8d post -frame threated nails with 0.135 nominal diameter %a" O.D. galvanized bolt or threaded rod w/ nuts & washers 2x8 min. deck joists & rims z'fz" min and 5" max Min. 1800# tension device 5/a" O.D. galvanized bolt or threaded rod w/ nuts & washers 4min ant 4x4 min. post @ 60" o.c. max., Typ 2"min Section A 2x8 min. blocking 2"min A_ Use above details for guard connections or provide engineered Min. 1800# tension straps "A design that shows Guards can resist a single concentrated load of 200 Ibs applied in any direction at any point along the top and Section B have attachment devices and supporting structure to transfer this load to appropriate structural elements of the building per IBC sec 1607.7.1.1 January 14, 2022 MyBuildingPermit.com I Basic Deck 1001 eeityGov.net A05 ! e0tV13ovAlliance SIMPSON AR SDWS22311 C BOTH SIDES ROOFING TO MATCH EXISTING SFR #50 ICE AND WATER SHIELD 1/2" CDX SHEATHING 2 X 10 D/F RAFTERS @ 24" O/C 6 X 12 D/F #2 H-1 SIMPSON CONNECTION 5/4 PRIMED FACIA 6 X 6 PT POST SIMPSON POST TO BEAM CONECTION L ROOF FRAMING DETAIL @ POST SCALE 3/4" = 1' BLD2024-1225 REVISION Oct 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT z O i= w 0 w} J m� m �w z� Ow w Ofw Q w m z CO T v� V LU LU V_ 7 lT v W V Y Q _J m } W z LU 0 � > tL � Q a Q Z Q z 0 DATE: 10/14/2024 SCALE: SHEET: F-4