Loading...
REV1 REVIEWED BLD2023-0098+Structural_Analysis_or_Calculations+7.9.2024_5.02.48_PM+4365751CQN REVISION Jul 10 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2023-0098 REVIEWED CITY OF EDMONDS CARTER QUINN NORLIN STRUCTURAL ENGINEERING STRUCTURAL CALCULATIONS Kleven Residence 734 Fir St Edmonds, WA 98020 Coupe Architecture PO Box 50645 Bellevue, WA 98015 07/09/2024 Supplemental Calculations �Oso WAS, � �Gc 4ss6s `�,w ww DNAL ����� ► 2033 Sixth Avenue #995 Seattle. WA 98121 206-264-7784 www.CQN-SE.com FRAMING PLAN NOTES: _TPIPICAL UNLESS NOTED OTHERWISE) I. ROOFSHFAIHING SHALL BETId PPA RATED SHEATHING (SPAN RATING 54132). NAIL® ALL FRAMED PANEL EDGES AND OVER SHEARWALLS M 1Od 06". AND 12'. TO ALL INTERMEDIATEFRAMING. SiRENGTHAXISSHALLBELAIDPEFPENDICUWITO SUPPORTS. AT EDGES NOTED ON PLAINS TEH PANEL SHALL HAVE A MIINMUM 4'L' SAMPAN. 2 SW_INDICATES STRUCTURAL WALL TYPE PER SCHEDULE 1256.1 SEE ARCHRECFUFALDRAWNGS FOR ADDITIONALWALL INFORMATION. S ALLHEADERSANO BEAMSARE MARKED ON PLAN. REFER NOTE 4 FOR SUPPORT REOUIRMENTS. 4. COLUMNSSHAIL BE DOUBLE STUDS MINIMUM, U.N.O., WITH BEAM OR HEADER BEARING FULLY ON COLUMN. 6. EASTINGSHEARWALL TO BE VERIFIED INFIELD. CONFIRM IR'CDXPLYWOODwIS® f.INSTALIEDWHEREVER(E)SWISINUICATEO. PLANPLAN NI NI ENTIRE FRAMING PLAN LEGEND WALLS BELOW WALLSABOVE N COLUMNS BELOW COLUMNS ABOVE ^ ' HANGER ABRUPT CHANGE IN SLABIFRAMING ELEVATION FUUSH INDICATES FLUSH BEAM CROP INDICATES DROPPED BEAM lmx INDICATES SINGLE SIDED SHEARWALL PER SCHEDULE)VSX.X. 2SWX INDICATES DOUR E SIDED SHFAmYALL PER SCHEDULE )VSX.A INDICATES DETAIL X ON SHEET SIXXX SPAN AND EXTENTS SPANANDEXTENTSTHROUGHOLR INDICATEBSIMPSON HOIDOWN. REFERTO HOLDOWN SCHEDULE (MAX) FOR THREADED RODCALLOUT 6 EMBEDMENT INTO CONCRETE INDICATES SIMPSON STRAP HOLDOWN 2033 6th Avenue, 999K SeaNe, WA 981 US Roof F—mg S2.3 aFORTEWEB' MEMBER REPORT Roof, Roof.- Header #3 2 piece(s) 2 x 8 HF No.2 PASSED 0 0 4 E Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1499 @ 1 1/2" 3645 (3.00") Passed (41%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 930 @ 10 1/4" 2501 Passed (37%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 1504 @ 2' 3" 2569 Passed (59%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.021 @ 2' 3" 0.142 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.039 @ 2' 3" 0.213 Passed (L/999+) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories IF Total Available Required Dead Snow Factored 1 - Trimmer - HF 3.00" 3.00" 1.50" 691 808 1499 None 2 - Trimmer - HF 3.00" 3.00" 1.50" 691 808 1499 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 4' 6" o/c Bottom Edge (Lu) 4' 6" o/c -Maximum allowable bracing intervals based on applied load. Dead Snow Vertical Loads Location Tributary (0.90) (1.15) Comments Width 0 - Self Weight (PLF) 0 to 4' 6" N/A 5.5 -- Linked from: Roof: 1 - Uniform (PLF) 0 to 4' 6" N/A 301.5 359.0 Joist #1, Support 1 0 Member Length : 4' 6" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ iocument-library. Fhe product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Natosha Norlin Carter Quinn Norlin (206) 264-7784 nln@cqn-se.com 7/8/2024 9:14:58 PM UTC ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2 Weyerhaeuser File Name: Kleven Paget/8 aFORTEWEB' MEMBER REPORT Roof, Roof.- Header #4A 2 piece(s) 1 3/4" x 7 1/4" 2.0E Microllam@ LVL PASSED 0 4 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2289 @ 1 1/2" 7613 (3.00") Passed (30%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 2180 @ 10 1/4" 5544 Passed (39%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 4542 @ 2' 3" 8182 Passed (56%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.045 @ 2' 3" 0.142 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.075 @ 2' 3" 0.213 Passed (L/684) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Factored 1 - Trimmer - HF 3.00" 3.00" 1.50" 898 1391 2289 None 2 - Trimmer - HF 3.00" 3.00" 1.50" 898 1391 2289 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 4' 6" o/c Bottom Edge (Lu) 4' 6" o/c -Maximum allowable bracing intervals based on applied load. Dead Snow Vertical Loads Location Tributary (0.90) (1.15) Comments Width 0 - Self Weight (PLF) 0 to 4' 6" N/A 7.4 1 - Uniform (PSF) 0 to 4' 6" 3' 15.0 25.0 Linked from: Roof: 2 - Point (lb) 2' 3" N/A 1560 2444 Ridge Beam #2B, Support 1 0 Member Length : 4' 6" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Natosha Norlin Carter Quinn Norlin (206) 264-7784 nln@cqn-se.com 7/8/2024 9:14:58 PM UTC ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2 Weyerhaeuser File Name: Kleven Page 3/8 aFORTEWEB' MEMBER REPORT Roof, Roof Header #4B 1 piece(s) 6 x 8 DF No.1 PASSED 0 0 d 6'' E Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2750 @ 1 1/2" 10313 (3.00") Passed (27%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 2662 @ 10 1/2" 5376 Passed (50%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 5590 @ 2' 3" 5930 Passed (94%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.028 @ 2' 3" 0.142 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.047 @ 2' 3" 0.213 Passed (L/999+) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories IF Total Available Required Dead Snow Factored 1 - Trimmer - HF 3.00" 3.00" 1.50" 1111 1639 2750 None 2 - Trimmer - HF 3.00" 3.00" 1.50" 1111 1639 2750 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 4' 6" o/c Bottom Edge (Lu) 4' 6" o/c -Maximum allowable bracing intervals based on applied load. Dead Snow Vertical Loads Location Tributary (0.90) (1.15) Comments Width 0 - Self Weight (PLF) 0 to 4' 6" N/A 10.4 1 - Uniform (PSF) 0 to 4' 6" 2' 20.0 25.0 Linked from: Roof: 2 - Point (lb) 2' 3" N/A 1995 3053 Ridge Beam #2A, Support 1 0 Member Length : 4' 6" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ iocument-library. fhe product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Natosha Norlin Carter Quinn Norlin (206) 264-7784 nln@cqn-se.com 7/8/2024 9:14:58 PM UTC ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2 Weyerhaeuser File Name: Kleven Page 4/8 FRAMING PITAN NOIRES (IYEICAL UNLESS NOTED OTHERWISE) 1. FLOOR SHEATHING SHALLBE MZ AAA, STURM1-FLOORWITH A PANEL INDUCE 4020. NAILTO FRAMING WITH 10A03MMON NAILS ® M ® PANEL EDGES AND 1P.IN FIELD UNLESS NOTED OTHERWISE ON PLANS. 2. EATERIORWALLSHEATHING SLWL BE 15R2'APA PATEDSHEATHING WITHA PANEL INDEX OF 2410(ORIEINTED STRAND BOARD OF EQUIVALENT THICKNESS,EXPOSURE NAURU, AND PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD AT OONTRACTORS wNl. 9. SW-- INDICATES STRUCTURALWALLTYPE PER SCHEDULE FORIM ION SEE NiCHEADER SANBEAMSDRAWINGS FOAAOOITONALWNL IEFER NOTO 4. ALLHEADENSAND BEAMS AAE MAAKEDON PLAN. REFER NOTESFOR SUPPORT REQUIRMENTS 5. FULLY ON SHALL BE DOUBLE STUDS MINIMUM, U.N 0., WITH BEAM OR HEADER BEARING RESIGN B COLUMN. 6, DESIGNBUILDRAT DL SHALL CONFORM TOSRC 0PSF DESIGNED TO RESIST A COMPONENTS LOADg41HETOP AAILPNO Sa PSFON ALLGUARORAIL INFILL COMPONENTS. T. %ISTNG WALLTO BEINFIELD. CONFR"W%PLYWOO 4'acINSLLEDWHERER(E)SWISINDICTED. LUS48 LIPUer Floor Framing FRAMING PLAN LEGEND WALLS BELOW WALLSABOVE N COLUMNS BELOW COLUMNS ABOVE ^ ' HANGER ABRUPT CHANGE IN SLABIFRAMING ELEVATION FLUSH INDICATES FLUSH BEAM CROP INDICATES DROPPED BEAM lSWX INDICATES SINGLE SIDED SHEARWALL PER SCHEDULEIVS%.%. 2SW% INDICATES DOUR E SIDED SHEAIWiALL PER SCHEDULE XIS%.%. INDICATES DETAIL %ON SHEET SIX XX SPAN AMID EXTENTS SPAN AND EXTENTS THROUGHOUT INDICATES IIMPSON HOLOOWN. REFER TO HOLDOWN SCHEDULE (YJSXX) FOR THREADED RODCNLOUT 6 EMBEDMENT INTO CONCRETE INDICATES 3IMPSON STRAP HOLDOWN 2033 GM Avenue, 3995 Suffle, WA 98109 W U z W In VN W W w� Lu o he xw UpperFl— F—II,g S2.2 FRAMING PITAN NOTES (IYEICAL UNLESS NOTED OTHERWISE) FRAMING PLAN LEGEND 1. FLOOR SHEATHING SHALL BE MZ ARA, STURDEI-FLOOR WITH A PANEL INDEX OF WALLS BELOW 40@0. NAIL TO FRAMING WITH IW COMMON NAILS 4 Y 6 PANEL EDGES AND 1T.IN INDICATES DETAIL %ON SHEET SIX X% FIELD UNLEBE NOTED OTHERWISE ON PLANS. 2. EATERIORWALLSHEATHING SHALL BE 15R2'APA PATEDSHEATHING WFHA PANEL WALLSABOVE \_ INDEX OF 2410(ORIEINTED STRAND BOARD OF EQUIVALENT THICKNESS,EXPOSURE RATING, AND PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD AT CONTRACTORS N COLUMNS BELOW B SPAN AMID EXTENTS OPTION). COLUMNS ABOVE 9. SW- _INDICATES STRUCTURALWALLTYPEPERSCHEOULE SEE FORIM ION NiCHEADERPAND BEAMSAREMAROI110NALWNLINWAMATEO 4. ALLHEAOENSAND BEAMS AAE MAPNEDON PLAN. REFER NOTESF0RSUPPORT ^ '� HANGER SPAN ANO EXTENiSTHAWGHOIF RDLUMNS NTS 5. SHALL BE DOUBLE STUDS MINIMUM, U.N O., WITH BEAM 0A HEADER BEARING SHALL FRS ABRUPT CHANGE IN 3LABIFRAMING ELEVATION FULLY ON FULLY B COLUMN. DESIGNED TORESIST A 6, DESIGN BUILD HANDRAILSDMH INDICATES SCHEDUL ENFORMTOSRC0PSF CONCENTRATED LOADgJ iHETOP AAILPNO50 PSFON ALLGUARORAIL INFILL FLUSH INDICATES FLUSH BEAM UQSXX)N. FOR HDDCW SCHEDULEDMEN�NTO THREADED COMPONENTS COMPONENTS. RCOCNLOUi6EMBEDMENi INTO CONCRETE 1. EXISTING SHEARWALL TO BE VENTED IN FIELD. CONFIRM IR"CO%PLYWOOD W SO® CROP INDICATES DROPPED BEAM 4- ac INSTALLED WHEREYER(E) SW IS INDICATED. INDICATE531MP30N STRAP HOEDOWN 15W% INDICATES SINGLESIDED SHEARWALL PER SCHEOULEIVS%.%. 2SW% INDICATES DOUR E SIDED SHEARWALL PER SCHEDULE )USX .%. Ha C4f0 HANGER ,i (E)SW PERPLAN L. (E)SW El SW RAN (E)SW PER PLAN NOIEi 1e4N0� ss FIR i— e OR 6'/uBXPSL SY�dISPSL FOR Ipl 4.10 35� LEDGER Nd(2 'II LAG jr. )M HDR i yy p�ppLA 2x10 LEDGERxtl(2)ROWSX' (E)SW PER PLAN �� (4)DTTIZTIES TYP UNO E1 O.6'LAGS®1Tac TYR UNO NOTE ATTACH PER SIS6.1 w 2U0LEDGERxtl(2) 1, (4)OTTIZTIE9 R TTT ROWS %'Onf'LAGS mo ATTACHPER61S6.1 N 2a106 a Q12ta TYPUNO _-pip DOUBLETOP PLATE O TYPD z� WALL, HALF ON WALL AND JOIST NO HALF ON HEADER � %(eI�10X IBVIF 11 � I / qII y�Al '4't 11 �a.¢ 5Fu12 GLB VIF I 4x10F 4XTBEB V L = I - 66 — \\ �� GS14M 4'f)"INSTALL ON 1\ II OOUBIETOP PLATE OF fO/Fj �q j \ II WPLL, HALF ON WALLPNO (E)CONCRETE HNFIXJ HEADER WALLVIF � !n CONCRETE STAIR ON GRADE PER 03.0 Main Level Fami.g SITE RETAKING WALL PER ARCH REFERTO INS3.0 STAIR ONGRAOE PER a FO RT E W E B MEMBER REPORT PASSED Main Floor, MF: Header #16 1 piece(s) 5 1/8" x 15" 24F-V4 DF Glulam 0 NMI 0 9 E Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) [Group] Member Reaction (Ibs) 4483 @ 1 1/2" 9994 (3.00") Passed (45%) 1.0 D + 1.0 L (All Spans) [1] Shear (Ibs) 4163 @ 1' 6" 13581 Passed (31%) 1.00 1.0 D + 1.0 L (All Spans) [1] Pos Moment (Ft-Ibs) 31134 @ 9' 38121 Passed (82%) 1.00 1.0 D + 1.0 L (All Spans) [1] Live Load Defl. (in) 0.370 @ 9' 2 5/16" 0.456 Passed (L/592) 1.0 D + 1.0 L (All Spans) [1] Total Load Defl. (in) 0.617 @ 9' 2 7/16" 0.608 Passed (L/355) 1.0 D + 1.0 L (All Spans) [1] • Deflection criteria: ILL (L/480) and TL (L/360). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume/size factor of 0.99 that was calculated using length L = 18' 3". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Factored 1 - Trimmer - HF 3.00" 3.00" 1.50" 2046 2437/-17 4483 None 2 - Trimmer - HF 3.00" 3.00" 1.50" 2016 2333 4349 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 18' 6" o/c Bottom Edge (Lu) 18' 6" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Vertical Loads Location Tributary (0.90) (1.00) Comments Width 0 - Self Weight (PLF) 0 to 18' 6" N/A 18.7 1 - Uniform (PSF) 0 to 18' 6" 16' 3" 7.5 - Wall Weight 2 - Uniform (PSF) 0 to 18' 6" 1' 3 15/16" 15.0 40.0 Residential Loading Linked from: MR 3 - Point (lb) 9' N/A 1093 3786/-992 Beam #10, Support 3 Member Length : 18' 6" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Natosha Norlin Carter Quinn Norlin (206) 264-7784 nln@cqn-se.com 7/8/2024 9:14:58 PM UTC ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2 Weyerhaeuser File Name: Kleven Page 5/8 a FORTE rV GB MEMBER REPORT FAILED Main Floor, MF. Beam 16 w/ Hold downs 1 piece(s) 5 1/8" x 15" 24F-V4 DF Glulam An excessive up i - ort located at 1 1/2" failed this product. An excessive uplift of -1313 Ibs at support located at 18' 4 ct. uplift resovled w/ existing CC cap @ beam end Overall Length: 18' 6" I I 18' it ❑2 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) [Group] Member Reaction (Ibs) 6510 @ 1 1/2" 9994 (3.00") Passed (65%) 1.0 D + 0.525 E + 0.75 L + 0.75 S (All Spans) 1 Shear (Ibs) 4163 @ 1' 6" 13581 Passed (31%) 1.00 1.0 D + 1.0 L (All Spans) [1] Pos Moment (Ft-Ibs) 31134 @ 9' 38121 Passed (82%) 1.00 1.0 D + 1.0 L (All Spans) [1] Neg Moment (Ft-Ibs) -8054 @ 1T 3" 47406 Passed (17%) 1.60 0.6 D - 0.7 E (All Spans) [1] Live Load Defl. (in) 0.370 @ 9' 2 1/4" 0.456 Passed (L/592) -- 1.0 D + 1.0 L (All Spans) [1] Total Load Defl. (in) 0.617 @ 9' 2 7/16" 0.608 Passed (L/355) - 1.0 D + 1.0 L (All Spans) [1] • Deflection criteria: LL (L/480) and TL (L/360). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume/size factor of 0.99 that was calculated using length L = 18' 3". • Critical negative moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 7' 15/16". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Bearing Length Loads to Supports (Ibs) Total Available Required Dead Floor Live Seismic Factored Supports Accessories 1 -Trimmer - HF 3.00" 3.00" 1.95" 2046 2437/-17 50211-502 6510/-2287 None 2 - Trimmer- HF 3.00" 3.00" 1.70" 2016 2333 3604/-360 5658/-1313 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 18' 6" o/c Bottom Edge (Lu) 18' 6" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Seismic Vertical Loads Location Tributary (0.90) (1.00) (1.60) Comments Width 0 - Self Weight (PLF) 0 to 18' 6" N/A 18.7 1 - Uniform (PSF) 0 to 18' 6" 16' 3" 7.5 - - Wall Weight 2 - Uniform (PSF) 0 to 18' 6" 1' 3 15/16" 15.0 40.0 Residential Loading Linked from: MR 3 - Point (Ib) 9' N/A 1093 3786/-992 Beam #10, Support 3 4 - Point (lb) 1' 6" N/A - - 8625 5 - Point (Ib) 7' N/A -8625 6 - Point (lb) 13' 3" N/A 8625 ForteWEB Software Operator Job Notes Natosha Norlin Carter Quinn Norlin (206) 264-7784 nln@cqn-se.com Member Length : 18' 6" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD 7/8/2024 9:14:58 PM UTC ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2 Weyerhaeuser File Name: Kleven Page 6/8 a FO RT E W E B MEMBER REPORT FAILED Main Floor, Beam 19 1 piece(s) 5 1/4" x 9 1/2" 2.0E Parallam@ PSL An at support located at 3' 4 Strap provided for standard hold down forces (not omega level) MSTC48133 on Each side of beam. Overall Length: 3' 6" I 11 I 3' it ❑2 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 7883 @ 1 1/2" 9844 (3.00") Passed (80%) 1.0 D + 0.7 E (All Spans) Shear (Ibs) 6489 @ 2' 5 1/2" 15428 Passed (42%) 1.60 1.0 D - 0.7 E (All Spans) Moment (Ft-Ibs) 6155 @ 2' 6" 31337 Passed (20%) 1.60 1.0 D - 0.7 E (All Spans) Live Load Defl.(in) 0.004 @ 1' 7 1/2" 0.081 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.007 @ 1' 7 5/8" 0.108 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/480) and TL (L/360). • Allowed moment does not reflect the adjustment for the beam stability factor. Member Length : 3' 6" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Bearing Length Loads to Supports (Ibs) Total Available Required Dead Floor Live Snow Seismic Factored Supports Accessories 1 - Trimmer- HF 3.00" 3.00" 2.40" 1412 543 1324 9244/-924 7883/-5624 None 2 - Trimmer - HF 3.00" 3.00" 2.19" 729 543 315 92444/-924 7200/-6034 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 3' 6" o/c Bottom Edge (Lu) 3' 6" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Snow Seismic Vertical Loads Location Tributary (0.90) (1.00) (1.15) (1.60) Comments Width 0 - Self Weight (PLF) 0 to 3' 6" N/A 15.6 -- -- -- 1 - Uniform (PSF) 0 to 3' 6" 16' 3" 10.0 - Wall Weight 2 - Uniform (PSF) 0 to 3' 6" 7' 9" 15.0 40.0 Residential Loading 3 - Point (lb) 6" N/A - - 1502 4 - Point (lb) 2' 6" N/A - - -15022 Linked from: Roof 5 - Point (lb) 9" N/A 1111 1639 - Header #4B, Support 2 Omega level forces Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Natosha Norlin Carter Quinn Norlin (206) 264-7784 nln@cqn-se.com 7/8/2024 9:19:35 PM UTC ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2 Weyerhaeuser File Name: Kleven Page 1 / 1 Seismic Project: Kleven Residence Seismic Design Parameters Site Class D Risk Category II Importance Factor 1 Ss 1.281 S1 0.450 Fa 1.200 Fv 1.850 Sms 1.537 S m 1 0.833 Sds 1.025 Sd 1 0.555 R 6.5 CS 0.158 k 1 p 1.3 Seismic Desien Cateeory D Seismic Weight Areas (ft) Roof 1815 Upper Level 1220 Main Level 1800 -- 0 -- 0 Table 1.5-1 Table 1.5-2 From USGS Table 11.4-1 Table 11.4-2 Eq. 11.4-1 Eq. 11.4-2 Eq. 11.4-3 Eq. 11.4-4 Table 12.2-1 Ea. 12.8-2 T Loads DL-Floor (psf) 15 DL-Roof (psf) 15 DL-Solar (psf) 5 Seismic Base Shear Vultimate (k) 12.9 E Vallowable (k) 9.0 Level Weight (k) IHeight (ft) WXf.k C'X F. (ult.) F. (allow.) Roof 36.3 24.75 898.4 0.63 8.1 5.6 Upper Level 18.3 17 311.1 0.22 2.8 2.0 Main Level 27 8.25 222.8 0.16 2.0 1.4 -- 0 0 0.0 0.00 0.0 0.0 - 0 0.0 0.00 0.0 0.0 TOTAL 81.6 - 1432.3 1 12.9 9.0 All references are from ASCE 7-15: Minimum Design loads and Associated Criteria for Buildings and Other Structures Wind Project' Kleven Residence Wind Load Parameters Chapter 28- Envelope Procedure Sec. 26.7 Exposure B Risk Category II Table 1.5-1 Mean Roof Height (ft) 24.75 Roof Slope (X/12) 3 Angle 14.0 a (ft) 3 Figure 28.3-1 Note "a" Kd 0.85 Table 26.6-1 K,f 1 V (mph) 97 K, 0.70 Table 26. 10-1 qh (psf) 14.33 Eq. 26.10-1 Minimum Wind Pressure on Walls (psf) 16 Minimum Wind Pressure on Sec. 28.3.4 Building Geometry Level Height (ft) Trib. Height (ft) Load Case A Direction (ft) Load Case B Direction (ft) Plan North/South Plan East/West Above Roof 3.75 3.75 52 28 Roof 8.5 4.25 52 28 Upper Level 8.5 8.5 52 28 Main Level 8.5 8.5 52 28 0 0 0 0 0 0 0 0 Height below Level "Rectangle" Dimension "Pentagram" Dimension GCpf Values Summary (28.3-1) Building Surface Load Case A Load Case B Roof 0.25 Roof Corners 0.44 - Wall 0.85 0.69 Wall Corners 1.28 1.04 Load Case A - Plan North/South Level A (ft) F = qh*GCpf*A (k) Total Wind Load (Ultimate, k) Minimum Load (Ultimate, k) Total (allowable, k) Roof - roof 173 0.61 0.75 1.56 0.94 Corners 23 0.14 Roof - walls 196 2.39 2.86 3.54 2.12 Corners 26 0.47 Upper Level 391 4.78 5.71 7.07 4.24 Corners 51 0.94 Main Level 391 4.78 5.71 7.07 4.24 Corners 51 0.94 -- 0 0.00 0.00 0.00 0.00 Corners 0 0.00 -- 0 0.00 0.00 0.00 0.00 Corners 0 0.00 Load Case B - Plan East/West Level A (ft) F = qh*GCpf*A (k) Total Wind Load (Ultimate, k) Minimum Load (Ultimate, k) Total (allowable, k) Roof - roof 83 0.82 0.98 0.75 0.59 Corners 11 0.17 Roof - walls 94 0.92 1.11 1.70 1.02 Corners 13 0.19 Upper Level 187 1.85 2.23 3.40 2.04 Corners 26 0.38 Main Level 187 1.85 2.23 3.40 2.04 Corners 26 0.38 -- 0 0.00 0.00 0.00 0.00 Corners 0 0.00 - 0 0.00 0.00 0.00 0.00 Corners 0 0.00 Wind Loads Summary Plan North/South Plan East/West Level Wind Load (Ultimate, k) Wind Load (Allowable, k) Wind Load (Ultimate, k) Wind Load (Allowable, k) Roof 5.10 3.06 2.68 1.61 Upper Level 7.07 4.24 3.40 2.04 Main Level 7.07 4.24 3.40 2.04 -- 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Base Shear 1 19.24 11.54 1 9.48 5.69 WL-E Level Total Wall Line Seismic Forces (k) Wind Forces (k) Story Heights (ft) Lengths (ft) Roof 34.5 2.82 1.50 7.75 Upper Level 41 3.80 3.39 7.75 Main Level 33 4.50 5.28 7.5 0 0 Max H/W Ratio 2 3.5 ROOF Length (ft) H/W Ratio 1 Increase Force in Wall Elements Dead Loads Seismic Overturning (k) Wind Overturning (k) Seismic Shear (plf) Wind Shear (plf) Wall (lb) Floor (Ib) (ASD) (ASD) 19.5 0.40 1.00 82 43 1511 195 0.04 -0.18 15 0.52 1.00 82 43 1163 150 0.18 -0.06 SW-1 UPPER LEVEL 1 Force in Wall Elements Dead Loads Seismic Overturning (k) Wind Overturning (k) Length (ft) H/W Ratio Increase Seismic Shear (plf) Wind Shear (plf) Wall (lb) Floor (Ib) (ASD) (ASD) 22.75 0.34 1.00 93 83 1763 228 0.02 0.04 18." 0.42 1.00 93 83 1414 183 0.16 0.16 Tie MAIN LEVEL 1 Force in Wall Elements Dead Loads Seismic Overturning (k) Wind Overturning (k) Length (ft) H/W Ratio Increase Seismic Shear (Dlf) Wind Shear folf) Wall (Ibl Floor (Ib) (ASD) (ASD) Holdown Line Increase per 4.3.4.2 ANSI/AWC SDPWS-2015 Per Table 4.3.4 ANSI/AWC SDPWS-2015 As Built: Nailing for Shear Wall (LINO P;C,�, MKT. Ir `Il a. 6 `"� 31 -,0 9e T U o, c, 0 PAf4--: E3 aeAl Al e d 6 V^L_V ti4 capacity= 350 W L-W Total Wall Line Level Seismic Forces (k) Wind Forces (k) Story Heights (ft) Lengths (ft) Roof 7.5 2.824 1.50 7.75 Upper Level 8.5 3.80 3.39 7.75 Main Level 29.834 4.50 5.28 7.5 0 0 Max H/W Ratio z 3.5 ROOF Length (ft) H/W Ratio Increase Force in Wall Elements 1 Seismic Shear (plf) Wind Shear 3.5 2.21 1.03 387 199 2 1.00 1.00 377 199 2 1.00 1.00 377 199 Dead Loads Wall (lb) Floor 271 35 155 20 155 20 Seismic Overturning (k) Wind Overturning (k) (ASD) (ASD) 2.81 6.09 s 20 omega level for 6.09 3.20 discontinuous:2.5 ( Shear Wall SW-3 I ( Strap Tie I MSTC52 UPPER LEVEL 1 Force in Wall Elements Dead Loads Seismic Overturning (k) Wind Overturning (k) Length (ft) H/W Ratio Increase Seismic Shear (plf) Wind Shear (plf) Wall (Ib) Floor (Ib) (ASD) (ASD) 3.5 2.21 1.03 460 399 271 341 3.25 2.91 5 1.55 1.00 447 399 388 488 3.16 2.83 Shear Wall SW-4 Strap Tie MSTC52 MAIN LEVEL Length (ft) H/W Ratio Increase' Force in Wall Elements Dead Loads Seismic Overturning (k) Wind Overturning (k) Seismic Shear If Wind Shear If Wall Ib Floorfib) ASD ASD 14 0.54 1.00 151 177 1050 1365 0.29 0.60 3.167 2.37 1.05 158 177 238 309 0.94 1.16 4.5 1.67 1.00 151 177 338 439 0.86 1.10 3.167 2.37 1.05 158 177 238 309 0.94 1.16 5 1.50 1.00 151 177 375 488 0.83 1.07 Holdown Line 1 Increase per 4.3.4.2 ANSI/AWC SDPWS-2015 Z Per Table 4.3.4 ANSI/AWC SDPWS-2015 W L-N Level Total Wall Line Seismic Forces (k) Wind Forces (k) Story Heights (ft) Lengths (ft) Roof 10.75 2.82 1.53 7.75 Upper Level 8.25 3.80 3.65 7.75 Main Level 6 4.50 5.77 7.5 0 0 Max H/W Ratio 2 3.5 ROOF 1 Force in Wall Elements Dead Loads Seismic Overturning (k) Wind Overturning (k) Length (ft) H/W Ratio Increase Seismic Shear (plf) Wind Shear (plf) Wall (lb) Floor (lb) (ASD) (ASD) 6.25 1.24 1.00 263 142 484 656 1.64 0.76 4.5 1.72 1.00 263 142 349 473 1.75 0.86 Shear Wall I SW-2 UPPER LEVEL - - ---- - Seismic Shear (pit) Wind Shear (pit) Wall ( 4.5 1.72 1.00 461 442 349 3.75 2.07 1.01 465 442 291 Strap Tie I MSTC40 Is Seismic Overturning (k) Wind Overturning (k) Floor (lb) (ASD) (ASD) 68 3.43 3.30 56 3.45 3.33 ) Shear Wall ( SW-4 ( ( Strap Tie ( MSTC52 MAIN LEVEL 1 Force in Wall Elements Dead Loads Seismic Overturning (k) Wind Overturning (k) Length (ft) H/W Ratio Increase Seismic Shear (plf) Wind Shear (plf) Wall (lb) Floor (lb) (ASD) (ASD) 3 2.50 1.07 750 963 675 405 1.55 1.99 3 2.50 1.07 750 963 675 405 1.55 1.99 Shear Wall I SW-6 I I Holdown IUSE FTAO HOLD DOWN FORCE = 1983 LB Holdown Line 1 Increase per 4.3.4.2 ANSI/AWC SDPWS-2015 2 Per Table 4.3.4 ANSI/AWC SDPWS-2015 Project Information Code: Date: 7/2/2024 Designer: NLN Client: COUPE Arch Project: Kleven Residence Wall Line: Wall Line N Main Floor I llfrl I nl Ifil I �lfrl V(Ib) 2 Shear Wall Calculation Variables L1 3.00 ft ha 1.25 ftl Wall Pier Aspect Ratio Adj. Fact L2 3.00 ft ho 7.00 ft P1=ho L1= 2.33 0.958 hwau 8.25 ft hb 0.00 ft P2=hJL2= 2.33 0.958 Lwau 24.00 ft Lol 18.00 ft 1. Hold-down forces: H = Vhw,ii/Lw,ii 1983 Ibf 2. Unit shear above + below opening First opening: vat = vbl = H/(ha+hb) = N/A 3. Total boundary force above + below openings First opening: Ol = val x (Lol) _ 4. Corner forces F1 = O1(Ll)/(L1+L2) _ F2 = O1(L2)/(L1+L2) _ 5. Tributary length of openings Tl = (L1*Lol)/(L1+L2) = 9.00 ft T2 = (L2*Lol)/(L1+L2) = 9.00 ft 6. Unit shear beside opening v1 = (V/L)(Ll+T1)/Ll = 962 plf v2 = (V/L)(T2+L2)/L2 = 962 plf Check vl*L1+v2*L2=V? 5770 lbf OK 7. Resistance to corner forces Rl = v1*L1 = 2885 Ibf R2 = v2*1_2 = 2885 Ibf 8. Difference corner force + resistance R1-F1 = R2-F2 = 9. Unit shear in corner zones vcl = (Rl-F1)/Ll vc2 = (R2-F2)/L2 leck Summary of Shear Values for One Opening ne 1: vcl(h,+hb)+vl(h,)=H? 6732 ne 2: va1(ha+hb)-vc1(ha+hb)-v1(h,)=0? 6732 ne 3: val(h,+hb)-vc2(h,+hb)-vl(h,)=0? 6732 ne 4: vc2(ha+hb)+v2(ho)=H? 6732 Design Summary* Req. Sheathing Capacity N/A 4-Term Deflection 3-Term Deflection Req. Strap Force 4-Term Story Drift % 3-Term Story Drift Req. HD Force (H) 1983 Ibf Req. Shear Wall Anchorage Force N—) 240 plf *The Design Summary assumes that the shear wall is designed as blocked. WL-S Level Total Wall Line Seismic Forces (k) Wind Forces (k) Story Heights (ft) Lengths (ft) Roof 13.75 2.82 1.53 7.75 Upper Level 7 3.80 3.65 7.75 Main Level 10.75 4.50 5.77 7.5 0 0 Max H/W Ratio z 3.5 ROOF Length (ft) H/W Ratio Increase' Force in Wall Elements Dead Loads Seismic Overturning (k) Wind Overturning (k) Seismic Shear (plf) Wind Shear (plf) Wall (Ib) Floor (Ib) (ASD) (ASD) 13.75 0.56 1.00 205 111 1066 1444 0.71 0.11 ( Shear Wall i SW-1 ( ( Strap Tie ( Strap Tie/Holdown Not Required UPPER LEVEL Force in Wall Elements Length (ft) H/W Ratio Increase' Seismic Shear (plf) Wind Shear 3.5 2.21 1.03 558 521 3.5 2.21 1.03 558 521 Dead Loads Seismic Overturning (k) Wind Overturning (k) Wall (Ib) Floor (Ib) (ASD) (ASD) 543 420 3.87 3.75 543 420 3.87 3.75 DU4 w/ (2) 2x MAIN LEVEL 1 Force in Wall Elements Dead Loads Seismic Overturning (k) Wind Overturning (k) Length (ft) H/W Ratio Increase Seismic Shear (plf) Wind Shear (plf) Wall (Ib) Floor (lb) (ASD) (ASD) 10.75 0.70 1.00 419 537 2419 1451 1.79 2.87 HDU8 where wall stacks. =3.87/2+1.79 = 5.66 ( Shear Wall i SW-3 ( ( Holdown ( HDU4 w/ (2) 2x Holdown Line ' Increase per 4.3.4.2 ANSI/AWC SDPWS-2015 2 Per Table 4.3.4 ANSI/AWC SDPWS-2015 !►'71►v1'1+'10 ' Anchor DesignerT"' Software Version 3.2.2311.2 1.Project information Project description: Location: Fastening description: 2. Input Data & Anchor Parameters General Design method:ACI 318-14 Units: Imperial units Anchor Information: Anchor type: Bonded anchor Material: F1554 Grade 36 Diameter (inch): 0.625 Effective Embedment depth, hef (inch): 7.000 Code report: ESR-5026 Anchor category: - Anchor ductility: Yes hmin (inch): 8.38 cap (inch): 11.35 Cmin (inch): 2.00 Smin (inch): 3.00 Recommended Anchor Anchor Name: AT-3GTM -AT-3G w/ 5/8"0 F1554 Gr. 36 Code Report: ESR-5026 H Company: Date: 9/6/2022 Engineer: I Page: 1 /5 Project: Address: Phone: E-mail: Base Material Concrete: Normal -weight Concrete thickness, h (inch): 24.00 State: Cracked Compressive strength, f'� (psi): 2500 qj.,v: 1.0 Reinforcement condition: B tension, B shear Supplemental edge reinforcement: Not applicable Reinforcement provided at corners: No Ignore concrete breakout in tension: Yes Ignore concrete breakout in shear: No Hole condition: Dry concrete Inspection: Continuous Temperature range, Short/Long: 150/110°F Reduced installation torque (for AT-3G): No Ignore 6do requirement: Not applicable Build-up grout pad: No Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com !►'71►v1'1+'10 ' Anchor Designer TM Software Version 3.2.2311.2 Load and Geometry Load factor source: ACI 318 Section 5.3 Load combination: not set Seismic design: Yes Anchors subjected to sustained tension: No Ductility section for tension: 17.2.3.4.2 not applicable Ductility section for shear: 17.2.3.5.2 not applicable Do factor: not set Apply entire shear load at front row: No Anchors only resisting wind and/or seismic loads: No Strength level loads: Nua [lb]: 2215 Wax [lb]: 0 Way [lb]: 0 <Figure 1> KI Company: Date: 9/6/2022 Engineer: Page: 2/5 Project: Address: Phone: E-mail: Z I 2215 lb 111%� Y 0 lb Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com !►'71►v1'1+'10 ' Anchor Designer TM Software Version 3.2.2311.2 <Figure 2> Company: Date: 9/6/2022 Engineer: Page: 3/5 Project: Address: Phone: E-mail: Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com E-71►��I�z•�►�■ Anchor DesignerT"' Software Version 3.2.2311.2 0 Company: Date: 9/6/2022 Engineer: Page: 4/5 Project: Address: Phone: E-mail: 3. Resulting Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, Nu. (lb) Vuax (lb) Way (lb) �(Vuax)z+(Vuay)z (lb) 1 2215.0 0.0 0.0 0.0 Sum 2215.0 0.0 Maximum concrete compression strain (%o): 0.00 Maximum concrete compression stress (psi): 0 Resultant tension force (lb): 0 Resultant compression force (lb): 0 Eccentricity of resultant tension forces in x-axis, e'Nx (inch): 0.00 Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00 4. Steel Strength of Anchor in Tension (Sec. 17.4.1) Nsa (Ib) rd ONsa (Ib) 13110 0.75 9833 0.0 6. Adhesive Strength of Anchor in Tension (Sec. 17.4.5) Tk,cr = Tkcrfshort-ter Ksat(f'c/ 2,500)nC[N.seis Tk,cr (psi) fshort-term Ksat (XN.seis f'c (psi) n Tk,cr (psi) 1110 1.00 1.00 0.95 2500 0.10 1055 Nba Tcr,7daher(Eq. 17.4.5.2) � a Tcr (psi) da (In) het (In) Nba (Ib) 1.00 1055 0.63 7.000 14494 0.750Na = 0.750 (ANa I ANao) Ved,Na V cp,NaNba (Sec. 17.3.1 & Eq. 17.4.5.1 a) ANa (in') ANao (In2) cNa (In) ca.min (In) Ved,Na Vp,Na Nao (lb) 143.34 321.02 8.96 4.00 0.834 m 14494 0.0 0. 55 0.75t^ (lb) 2631 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com E-71►��I�z•�►�■ Anchor Designer TM Software Version 3.2.2311.2 0 Company: Date: 9/6/2022 Engineer: Page: 5/5 Project: Address: Phone: E-mail: 11. Results Interaction of Tensile and Shear Forces (Sec. 17.6) Tension Factored Load, N­ (lb) Design Strength, oNn (lb) Ratio Status Steel 2215 9833 0.23 Pass Adhesive 2215 2631 0.84 AT-3G w/ 5/8" fd F1554 Gr. 36 with hef = 7.000 inch meets the selected design criteria. Pass (Governs) 12. Warnings - Concrete breakout strength in tension has not been evaluated against applied tension load(s) per designer option. Refer to ACI 318 Section 17.3.2.1 for conditions where calculations of the concrete breakout strength may not be required. - Per designer input, the tensile component of the strength -level earthquake force applied to anchors does not exceed 20 percent of the total factored anchor tensile force associated with the same load combination. Therefore the ductility requirements of ACI 318 17.2.3.4.2 for tension need not be satisfied — designer to verify. - Per designer input, the shear component of the strength -level earthquake force applied to anchors does not exceed 20 percent of the total factored anchor shear force associated with the same load combination. Therefore the ductility requirements of ACI 318 17.2.3.5.2 for shear need not be satisfied — designer to verify. - Designer must exercise own judgement to determine if this design is suitable. - Refer to manufacturer's product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com !►'71►v1'1+'10 ' Anchor DesignerT"' Software Version 3.2.2311.2 1.Project information Project description: Location: Fastening description: 2. Input Data & Anchor Parameters General Design method:ACI 318-14 Units: Imperial units Anchor Information: Anchor type: Bonded anchor Material: F1554 Grade 36 Diameter (inch): 0.625 Effective Embedment depth, hef (inch): 10.000 Code report: ESR-5026 Anchor category: - Anchor ductility: Yes hmin (inch): 11.38 cap (inch): 17.42 Cmin (inch): 2.00 Smin (inch): 3.00 Recommended Anchor Anchor Name: AT-3GTM -AT-3G w/ 5/8"0 F1554 Gr. 36 Code Report: ESR-5026 H Company: Date: 9/6/2022 Engineer: I Page: 1 /5 Project: Address: Phone: E-mail: Base Material Concrete: Normal -weight Concrete thickness, h (inch): 24.00 State: Cracked Compressive strength, f'� (psi): 2500 qj.,v: 1.0 Reinforcement condition: B tension, B shear Supplemental edge reinforcement: Not applicable Reinforcement provided at corners: No Ignore concrete breakout in tension: Yes Ignore concrete breakout in shear: No Hole condition: Dry concrete Inspection: Continuous Temperature range, Short/Long: 150/110°F Reduced installation torque (for AT-3G): No Ignore 6do requirement: Not applicable Build-up grout pad: No Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com !►'71►v1'1+'10 ' Anchor Designer TM Software Version 3.2.2311.2 Load and Geometry Load factor source: ACI 318 Section 5.3 Load combination: not set Seismic design: Yes Anchors subjected to sustained tension: No Ductility section for tension: 17.2.3.4.2 not applicable Ductility section for shear: 17.2.3.5.2 not applicable Do factor: not set Apply entire shear load at front row: No Anchors only resisting wind and/or seismic loads: No Strength level loads: Nua [lb]: 3750 Wax [lb]: 0 Way [lb]: 0 <Figure 1> KI Company: Date: 9/6/2022 Engineer: Page: 2/5 Project: Address: Phone: E-mail: Z I 3750 lb 111%� Y 0 lb Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com !►'71►v1'1+'10 ' Anchor Designer TM Software Version 3.2.2311.2 <Figure 2> Company: Date: 9/6/2022 Engineer: Page: 3/5 Project: Address: Phone: E-mail: Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com E-71►��I�z•�►�■ Anchor DesignerT"' Software Version 3.2.2311.2 0 Company: Date: 9/6/2022 Engineer: Page: 4/5 Project: Address: Phone: E-mail: 3. Resulting Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, Nu. (lb) Vuax (lb) Way (lb) �(Vuax)z+(Vuay)z (lb) 1 3750.0 0.0 0.0 0.0 Sum 3750.0 0.0 Maximum concrete compression strain (%e): 0.00 Maximum concrete compression stress (psi): 0 Resultant tension force (lb): 0 Resultant compression force (lb): 0 Eccentricity of resultant tension forces in x-axis, e'Nx (inch): 0.00 Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00 4. Steel Strength of Anchor in Tension (Sec. 17.4.1) Nsa (Ib) rd ONsa (Ib) 13110 0.75 9833 0.0 6. Adhesive Strength of Anchor in Tension (Sec. 17.4.5) Tk,cr = Tkcrfshort-ter Ksat(f'c/ 2,500)nC[N.seis Tk,cr (psi) fshort-term Ksat (XN.seis f'c (psi) n Tk,cr (psi) 1110 1.00 1.00 0.95 2500 0.10 1055 Nba Tcr,7daher(Eq. 17.4.5.2) � a Tcr (psi) da (In) het (In) Nba (Ib) 1.00 1055 0.63 10.000 20705 0.750Na = 0.750 (ANa I ANao) Ved,Na V cp,NaNba (Sec. 17.3.1 & Eq. 17.4.5.1 a) ANa (in') ANao (In2) cNa (In) ca.min (In) Ved,Na Vp,Na Nao (lb) 143.34 321.02 8.96 4.00 0.834 m 20705 0.0 0. 55 0.75t^ (lb) 3758 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com E-71►��I�z•�►�■ Anchor Designer TM Software Version 3.2.2311.2 0 Company: Date: 9/6/2022 Engineer: Page: 5/5 Project: Address: Phone: E-mail: 11. Results Interaction of Tensile and Shear Forces (Sec. 17.6) Tension Factored Load, N­ (lb) Design Strength, oNn (lb) Ratio Status Steel 3750 9833 0.38 Pass Adhesive 3750 3758 1.00 AT-3G w/ 5/8" fd F1554 Gr. 36 with hef = 10.000 inch meets the selected design criteria. Pass (Governs) 12. Warnings - Concrete breakout strength in tension has not been evaluated against applied tension load(s) per designer option. Refer to ACI 318 Section 17.3.2.1 for conditions where calculations of the concrete breakout strength may not be required. - Per designer input, the tensile component of the strength -level earthquake force applied to anchors does not exceed 20 percent of the total factored anchor tensile force associated with the same load combination. Therefore the ductility requirements of ACI 318 17.2.3.4.2 for tension need not be satisfied — designer to verify. - Per designer input, the shear component of the strength -level earthquake force applied to anchors does not exceed 20 percent of the total factored anchor shear force associated with the same load combination. Therefore the ductility requirements of ACI 318 17.2.3.5.2 for shear need not be satisfied — designer to verify. - Designer must exercise own judgement to determine if this design is suitable. - Refer to manufacturer's product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com !►'71►v1'1+'10 ' Anchor DesignerT"' Software Version 3.2.2311.2 1.Project information Project description: Location: Fastening description: 2. Input Data & Anchor Parameters General Design method:ACI 318-14 Units: Imperial units Anchor Information: Anchor type: Bonded anchor Material: F1554 Grade 36 Diameter (inch): 0.875 Effective Embedment depth, hef (inch): 16.000 Code report: ICC-ES ESR-4057 Anchor category: - Anchor ductility: Yes hmin (inch): 18.00 cap (inch): 38.63 Cmin (inch): 1.75 Smin (inch): 3.00 Recommended Anchor Anchor Name: SET-3GTA/ - SET-3G w/ 7/8" 0 F1554 Gr. 36 Code Report: ICC-ES ESR-4057 Company: Date: 9/6/2022 Engineer: Page: 1 /5 Project: Address: Phone: E-mail: Base Material Concrete: Normal -weight Concrete thickness, h (inch): 24.00 State: Cracked Compressive strength, f'� (psi): 2500 qjc,v: 1.0 Reinforcement condition: B tension, B shear Supplemental edge reinforcement: Not applicable Reinforcement provided at corners: No Ignore concrete breakout in tension: Yes Ignore concrete breakout in shear: No Hole condition: Dry concrete Inspection: Continuous Temperature range, Short/Long: 150/110°F Reduced installation torque (for AT-3G): Not applicable Ignore 6do requirement: Not applicable Build-up grout pad: No Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com !►'71►v1'1+'10 ' Anchor Designer TM Software Version 3.2.2311.2 Load and Geometry Load factor source: ACI 318 Section 5.3 Load combination: not set Seismic design: Yes Anchors subjected to sustained tension: No Ductility section for tension: 17.2.3.4.2 not applicable Ductility section for shear: 17.2.3.5.2 not applicable Do factor: not set Apply entire shear load at front row: No Anchors only resisting wind and/or seismic loads: No Strength level loads: Nua [lb]: 5660 Wax [lb]: 0 Way [lb]: 0 <Figure 1> KI Company: Date: 9/6/2022 Engineer: Page: 2/5 Project: Address: Phone: E-mail: Z I 5660 lb 0 lb Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com !►'71►v1'1+'10 ' Anchor Designer TM Software Version 3.2.2311.2 <Figure 2> Company: Date: 9/6/2022 Engineer: Page: 3/5 Project: Address: Phone: E-mail: Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com E-71►��I�z•�►�■ Anchor DesignerT"' Software Version 3.2.2311.2 0 Company: Date: 9/6/2022 Engineer: Page: 4/5 Project: Address: Phone: E-mail: 3. Resulting Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, Nu. (lb) Vuax (lb) Way (lb) �(Vuax)z+(Vuay)z (lb) 1 5660.0 0.0 0.0 0.0 Sum 5660.0 0.0 Maximum concrete compression strain (%o): 0.00 Maximum concrete compression stress (psi): 0 Resultant tension force (lb): 0 Resultant compression force (lb): 0 Eccentricity of resultant tension forces in x-axis, e'Nx (inch): 0.00 Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00 4. Steel Strength of Anchor in Tension (Sec. 17.4.1) Nsa (Ib) rd r6Nsa (Ib) 26795 0.75 20096 0.0 6. Adhesive Strength of Anchor in Tension (Sec. 17.4.5) Tk,cr = Tkcrfshort-ter Ksat(f'c/ 2,500)nC[N.seis Tk,cr (psi) fshort-term Ksat (XN.seis f'c (psi) n Tk,cr (psi) 1265 1.00 1.00 1.00 2500 0.24 1265 Nba Tcr,7daher(Eq. 17.4.5.2) � a Tcr (psi) da (In) het (In) Nba (Ib) 1.00 1265 0.88 16.000 55638 0.750Na = 0.750 (ANa I ANao) Ved,Na V cp,NaNba (Sec. 17.3.1 & Eq. 17.4.5.1 a) ANa (in') ANao (In2) cNa (In) ca.min (In) Ved,Na Vp,Na Nao (lb) 144.00 547.63 11.70 4.00 0.803 m 55638 0.0 0. 55 0.75t^ (lb) 5724 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com E-71►��I�z•�►�■ Anchor Designer TM Software Version 3.2.2311.2 0 Company: Date: 9/6/2022 Engineer: Page: 5/5 Project: Address: Phone: E-mail: 11. Results Interaction of Tensile and Shear Forces (Sec. 17.6) Tension Factored Load, N­ (lb) Design Strength, oNn (lb) Ratio Status Steel 5660 20096 0.28 Pass Adhesive 5660 5724 0.99 SET-3G w/ 7/8" fd F1554 Gr. 36 with hef = 16.000 inch meets the selected design criteria. Pass (Governs) 12. Warnings - Concrete breakout strength in tension has not been evaluated against applied tension load(s) per designer option. Refer to ACI 318 Section 17.3.2.1 for conditions where calculations of the concrete breakout strength may not be required. - Per designer input, the tensile component of the strength -level earthquake force applied to anchors does not exceed 20 percent of the total factored anchor tensile force associated with the same load combination. Therefore the ductility requirements of ACI 318 17.2.3.4.2 for tension need not be satisfied — designer to verify. - Per designer input, the shear component of the strength -level earthquake force applied to anchors does not exceed 20 percent of the total factored anchor shear force associated with the same load combination. Therefore the ductility requirements of ACI 318 17.2.3.5.2 for shear need not be satisfied — designer to verify. - Designer must exercise own judgement to determine if this design is suitable. - Refer to manufacturer's product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com