Loading...
REVIEWED BLD2023-1389+Structural_Analysis_or_Calculations+11.1.2023_1.53.20_PM+38749421 of 5 m-71 M • 11 S wam•7 info@b2engineers.com 425-318-7047 (0) 425-318-0031(C) REVIEWED BY CITY OF EDMONDS O'LEARY REMODEL 18810 84TH AVE W, EDMONDS, WA 98026 STRUCTURAL CALCULATIONS PROJECT NO: 23262 DATE:10/23/23 PREPARED BY: BASRI BASRI PE, SE Design Criteria International Building Code (IBC) 2018 American Society of Civil Engineers (ASCE) 7-16 RECEIVED Nov 06 2023 3t ELTO'I `tN'`E2Cts BLD2023-1389 Project Description The structural scope of the project is limited to removal of the load -bearing wall, situated between two existing bedrooms in the southern section of the house. This will be complemented by the introduction of a new beam, stud posts, and a corresponding footing. Attached, please find the detailed calculations for your reference. Live Load and Other Structural Criteria Roof Snow (psf) Residential Live Load (psf) Allowable Soil Bearing Pressure (psf) 25 40 1500 (assumed) ♦ E ♦♦ `�� F was S ♦♦ ♦ P o ti7 .p � ♦ �c� .Fj �pG 43789 CTURAL EN'O\ .� ♦♦ASS/ONAL E ♦♦•■.•♦♦ Project: OLEARY REMODEL B2 Engineers Location: CEILING JOIST CHECK StruCalc Version 11.1.8.0 Floor Joist Floor Joist [2018 International Building Code(2018 NDS)] 1.5 IN x 5.5 IN x 14.5 FT @16O.C. #2 - Douglas -Fir -Larch - Dry Use Section Adequate By: 3.6% Controlling Factor: Moment CAUTIONS The design dead load deflection exceeds the default maximum of 1/4" on spans (2). DEFLECTIONS Center Live Load 0.49 IN L/354 Dead Load 0.39 in Total Load 0.88 IN L/197 Live Load Deflection Criteria: L/240 Total Load Deflection Criteria: L/180 LOADING DIAGRAM 2 of 5 1 page 10/23/2023 5:27:31 PM of REACTIONS A B Live Load 181 lb 52 lb Dead Load 121 lb 69 lb Total Load 302 lb 121 lb Bearing Length 0.32 in 0.13 in SUPPORT LOADS A B Live Load 136 plf 39 plf Dead Load 91 plf 52 plf 14.5 ft Total Load 227 plf 91 plf MATERIAL PROPERTIES #2 - Douglas -Fir -Larch Base Values Adjusted Bending Stress: Fb = 900 psi Fb' = 1547 psi Cd=1.15 CF=1.30 Cr=1.15 Shear Stress: Fv = 180 psi Fv' = 207 psi Cd=1.15 Modulus of Elasticity: E = 1600 ksi E' = 1600 ksi Comp.1 to Grain: Fc -1= 625 psi Fc - -L' = 625 psi Controlling Moment: 942 ft-lb 3.34 Ft from left support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2 Controlling Shear: 299 lb At a distance d from left support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2 Comparisons with required sections: Read Provided Section Modulus: 7.3 in3 7.56 in3 Area (Shear): 2.17 in2 8.25 in2 Moment of Inertia (deflection): 19.03 in4 20.8 in4 Moment: 942 ft-lb 975 ft-lb Shear: 299lb 1139lb JOIST DATA Center Span Length 14.5 ft Unbraced Length -Top 0 ft Unbraced Length -Bottom 0 ft Floor sheathing applied to top of joists -top of joists fully braced. Floor Duration Factor 1.15 JOIST LOADING Uniform Floor Loading Center Live Load LL = 0 psf Dead Load DL = 5 psf Total Load TL = 5 psf TL Adj. For Joist Spacing wT = 6.7 plf Wall Loading Wall One Live Load (1 to Joists): L1 = 175 plf Dead Load (1 to Joists):D1 = 70 plf Load Location X1 = 3.25 ft Project: CLEARY REMODEL B2 Engineers Location: ROOF BEAM StruCalc Version 11.1.8.0 Roof Beam Roof Beam [2018 International Building Code(2018 NDS)] ( 3 ) 1.5 IN x 11.25 IN x 12.25 FT #2 - Douglas -Fir -Larch - Dry Use Section Adequate By: 4.2% Controlling Factor: Moment CAUTIONS Laminations are to be fully connected to provide uniform transfer of loads to all members DEFLECTIONS Center Live Load 0.19 IN L/793 Dead Load 0.10 in Total Load 0.29 IN L/515 Live Load Deflection Criteria: L/240 REACTIONS A B Live Load 1914 lb 1914 lb Dead Load 1036 lb 1036 lb Total Load 2950 lb 2950 lb Bearino Lenath 1.05 in 1.05 in BEAM DATA Span Length 12.3 ft Unbraced Length -Top 0 ft Unbraced Length -Bottom 0 ft Roof Pitch 4 :12 Roof Duration Factor 1.15 Notch Depth 0.00 MATERIAL PROPERTIES #2 - Douglas -Fir -Larch Total Load Deflection Criteria: L/180 Base Values Adjusted Bending Stress: Fb = 900 psi Fb' = 1190 psi Cd=1.15 CF=1.00 Cr=1.15 Shear Stress: Fv = 180 psi Fv' = 207 psi Cd=1.15 Modulus of Elasticity: E = 1600 ksi E' = 1600 ksi Comp.1 to Grain: Fc -1= 625 psi Fc - -L' = 625 psi Controlling Moment: 9034 ft-lb 6.125 ft from left support Created by combining all dead and live loads. Controlling Shear: -2537 lb At a distance d from support. Created by combining all dead and live loads. Comparisons with required sections: Read Provided Section Modulus: 91.08 in3 94.92 in3 Area (Shear): 18.38 in2 50.63 in2 Moment of Inertia (deflection): 186.71 in4 533.94 in4 Moment: 9034 ft-lb 9415 ft-lb Shear: -2537lb 6986lb LOADING DIAGRAM 10/23/2023 5:27:32 PM 12.25 ft ROOF LOADING Side One: Roof Live Load: LL = 25 psf Roof Dead Load: DL = 12 psf Tributary Width: TW = 12.5 ft Side Two: Roof Live Load: LL = 0 psf Roof Dead Load: DL = 0 psf Tributary Width: TW = 0 ft Wall Load: WALL = 0 plf SLOPE/PITCH ADJUSTED LENGTHS AND LOADS Adjusted Beam Length: Ladj = 12.25 ft Beam Self Weight: BSW = 11 plf Beam Uniform Live Load: wL = 313 plf Beam Uniform Dead Load: wD_adj = 169 plf Total Uniform Load: wT = 482 plf page of Project: CLEARY REMODEL B2 Engineers Location: STUD POST StruCalc Version 11.1.8.0 Column Column [2018 International Building Code(2018 NDS)] (3)1.5INx3.5INx8.OFT Stud - Hem -Fir - Dry Use Section Adequate By: 47.5% CAUTIONS * Laminations to be nailed together per National Design Specifications for Wood Construction Section 15.3.3.1 VERTICAL REACTIONS Live Load: Vert-LL-Rxn = 1914 lb Dead Load: Vert-DL-Rxn = 1059 lb Total Load: Vert-TL-Rxn = 2973 lb COLUMN DATA Total Column Length: 8 ft Unbraced Length (X-Axis) Lx: 8 ft Unbraced Length (Y-Axis) Ly: 8 ft Column End Condition-K (e): 1 Axial Load Duration Factor 1.15 COLUMN PROPERTIES Stud - Hem -Fir Compressive Stress: Bending Stress (X-X Axis): Bending Stress (Y-Y Axis): Modulus of Elasticity: Column Section (X-X Axis): Column Section (Y-Y Axis): Area: Section Modulus (X-X Axis): Section Modulus (Y-Y Axis): Slenderness Ratio: Base Values Adjusted Fc = 800 psi Fc' = 359 psi Cd=1.15 CF=1.05 Cp=0.37 Fbx = 675 psi Fbx' = 982 psi Cd=1.15 CF=1.10 Cr=1.15 Fby = 675 psi Fby' = 982 psi Cd=1.15 CF=1.10 Cr=1.15 E = 1200 ksi E' = 1200 ksi dx = 3.5 in dy = 4.5 in A = 15.75 in2 Sx = 9.19 in3 Sy = 3.94 in3 Lex/dx = 27.43 Ley/dy = 21.33 Column Calculations (Controlling Case Only): Controlling Load Case: Axial Total Load Only (L + D) Actual Compressive Stress: Fc = Allowable Compressive Stress: Fc' _ Eccentricity Moment (X-X Axis): Mx -ex = Eccentricity Moment (Y-Y Axis): My-ey = Moment Due to Lateral Loads (X-X Axis): Mx = Moment Due to Lateral Loads (Y-Y Axis): My = Bending Stress Lateral Loads Only (X-X Axis): Fbx = Allowable Bending Stress (X-X Axis): Fbx' _ Bending Stress Lateral Loads Only (Y-Y Axis): Fby = Allowable Bending Stress (Y-Y Axis): Fby' _ Combined Stress Factor: CSF = 189 359 0 0 0 0 0 982 0 982 0.53 psi psi ft-lb ft-lb ft-lb ft-lb psi psi psi psi LOADING DIAGRAM Sft y B A 10/23/2023 5:27:33 PM AXIAL LOADING Live Load: PL = 1914 lb * Dead Load: PD = 1036 lb * Column Self Weight: CSW = 23 lb Total Axial Load: PT = 2973 lb * Load obtained from Load Tracker. See Summary Report for details. Project: CLEARY REMODEL Location: FOOTING Footing Footing [2018 International Building Code(2018 NDS)] Footing Size: 1.5 FT x 1.5 FT x 10.00 IN Reinforcement: #4 Bars @ 11.00 IN. O.C. ENV / (2) min. Section Footing Design Adequate FOOTING PROPERTIES Allowable Soil Bearing Pressure: Qs = 1500 psf Concrete Compressive Strength: F'c = 2500 psi Reinforcing Steel Yield Strength: Fy = 40000 psi Concrete Reinforcement Cover: c = 3 in FOOTING SIZE Width: W = 1.5 ft Length: L = 1.5 ft Depth: Depth = 10 in Effective Depth to Top Layer of Steel: d = 6.25 in COLUMN AND BASEPLATE SIZE Column Type: Wood Column Width: m = 4 in Column Depth: n = 4 in FOOTING CALCULATIONS Bearing Calculations: Ultimate Bearing Pressure: Qu = 1321 psf Effective Allowable Soil Bearing Pressure: Qe = 1375 psf Required Footing Area: Areq = 2.16 sf Area Provided: A = 2.25 sf Baseplate Bearing: Bearing Required: Bear = 4333 lb Allowable Bearing: Bear -A = 44200 lb Beam Shear Calculations (One Way Shear): Beam Shear: Vu1 = 662 lb Allowable Beam Shear: Vc1 = 8438 lb Punching Shear Calculations (Two Way Shear): Critical Perimeter: Bo = 41 in Punching Shear: Vu2 = 2928 lb Allowable Punching Shear (ACI 11-35): vc2-a = 57656 lb Allowable Punching Shear (ACI 11-36): vc2-b = 77813 lb Allowable Punching Shear (ACI 11-37): vc2-c = 38438 lb Controlling Allowable Punching Shear: vc2 = 38438 lb Bending Calculations: Factored Moment: Mu = 9750 in -lb Nominal Moment Strength: Mn = 85454 in -lb Reinforcement Calculations: Concrete Compressive Block Depth: a = 0.41 in Steel Required Based on Moment: As(1) = 0.04 in2 Min. Code Req'd Reinf. Flex. Members (ACI-150.1): As(2) = 0.36 in2 Controlling Reinforcing Steel: As-reqd = 0.36 in2 Selected Reinforcement: #4's @ 11.0 in. o.c. e/w (2) Min. Reinforcement Area Provided: As = 0.39 in2 Development Length Calculations: Development Length Required: Ld = 15 in Development Length Supplied: Ld-sup = 6 in Note: Plain concrete adequate for bending, therefore adequate development length not required. B2 Engineers StruCalc Version 11.1.8.0 10/23/2023 5:27:33 PM LOADING DIAGRAM 10 in 4 in i 1.5 ft page of FOOTING LOADING Live Load: PL = 1914 lb' Dead Load: PD = 1059 lb Total Load: PT = 2973 lb Ultimate Factored Load: Pu = 4333 lb Footing plus soil above footing weight: Wt = 181 lb Load obtained from Load Tracker. See Summary Report for details. 3 in