APPROVED BLD2023-1646+Architectural_Plan+12.27.2023_9.11.11_AM+3971549STARK RES GA DENCE RAGE REMODEL 133 SUNSET AVE N EDMONDS, WA 98020 OWNER SUSAN STARK 133 SUNSET AVE N EDMONDS, WA 98020 425.478.8892 CONTACT: JSUSANSTARI<@GMAIL.COM CONSULTANTS STRUCTURAL ENGINEER CG ENGINEERING 250 4TH AVE S, SUITE 200 EDMONDS, WA 98020 425.778.8500 FAX 778.5536 CONTACT: DENNIS TITUS, PE, SE LEGAL DESCRIPTION EDMONDS PLAT OF BLK 013 D-00 - LOT 5 EXC ANY PTN THOF LY WITHIN BNRR R/W PARCEL NUMBER 00434401300500 PROPERTY INFORMATION TOTAL LOT AREA EX BUILDING FOOTPRINT PROPOSED BUILDING FOOTPRINT TOTAL IMPERVIOUS SURFACE SCOPE OF WORI< REMODEL EXISTING GARAGE ENTRY. NOTE: SITE PLAN HAS BEEN PREPARED BASED ON FIELD MEASUREMENTS & COUNTY RECORDS & IS NOT A SURVEY, PROPERTY LINES ARE APPROXIMATE. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS & UTILITY LOCATIONS. = 4,792 SQFT = 1,910 SQFT = NOT TO CHANGE = NOT TO CHANGE �►PFROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE SITE PLAN SCALE: 1" = V-0" NING WALL PrA DOUBLE GARAGE t SINGLE GARAGE a a s �¢ q = 2 Daley St ail Q � 'a� eP��sr s Sr ca �o � Q \ r P ,C m � apa aaS� a�n st 2 6P��Sr a e a ryC aP¢ `a ai p,¢ Je�PSsr �Cy, Mai ,? Bell St oaa Q AZ ✓a�Ps °`a Pug and �J �y Sr y Qy ¢ `tom Q h` - O Q amen St Main St a c N r =r oa�a \ aaP < m c Qa N a� kVOa on St W Dayton St Dayton St n n Yt Dayton St Dayton St o°a paw m w 3 a n y D n 7 m < d (N A LO U) Maple St rn d W 3 d 3 a — 0 Alder St VICINITY MAP NTS = PROJECT SITE 10 0 5 10 City Of Edmonds Building Department Work GARAGE DOOR ALTERATION Address 133 SUNSET N ------------------------ --------------------- Owner STARK Approved Date: 01 /02/2024 Building Official Eric Permit Number BLD2023-1646 C G ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 12101 / 23 m W F- .� 0 N c-I DESIGN: MDR DRAWN: JEG CHECK: DMT JOB NO: 23344.10 DATE: 1 2/01 /23 O Z � LEI W 00 U > O� Waa W W (n CY j ID � Z Iy O W Q M H- M ID V)�w z SHEET: RECEIVED Dec 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A001 14= ' ENGINES RING 250 4TH AVE. S., SUITE 200 10" 8'-0" '-2" 8'-0" 1'-8" EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 1'-10" 16'-0" V-10" FAX (425) 778-5536 DEMO CENTER R-21 INSULATION TO BE USED WALL PIER PER WSEC SECTION R406 — — — — — — — — — — — — — — — ----------— I I O O I I I\�� i�/I I\�� i�/I I I• O I I I CLOSET I BATH CLOSET I I �� , I I �� ,� I I CLOSET I BATH CLOSET I M. TI 1PAS�l ([�y --------------- y-� r DEMO EXIST GARAGE DOORS PROPOSED 16'-0" �L 1� 1 GARAGE DOOR ssjoNAL 12101 / 23 MASTER BEDROOM OFFICE MASTER BEDROOM OFFICE GARAGE GARAGE ENTRY ENTRY J I Q I IL7 I I I I z 2 1 O Co KITCHEN I KITCHEN U P UP I c� DN O0110O DN 0 u w w 0 a M W r*4 Q O NOOK NOOK Y LIVING LIVING DINING DINING DESIGN: MDR DRAWN: JEG CHECK: DMT DECK DECK JOB NO: 23344.10 DATE: 12/01 /23 EXISTING DEMO MAIN FLOOR PLAN PROPOSED MAIN FLOOR PLAN 1 SCALE: 1/4" = V-0" SCALE: 1/4" = V-0" 2'-0" 0 2'-0" 4'-0" 2'-0" 0 2'-0" 4'-0" f ^ V ! z IL O Z 0 J w w 00 Q U > o) w Q Q � V)n w � z o � Y v' zo = QM� U w N W SHEET: RECEIVED Dec 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Alml ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 REMOVE EXIST GARAGE DOORS ❑ Zg M. T ® of waste 1� i op 45901 El❑ sSIONAL Ell 12/01/23 0 1 _u ❑ ❑ IIII IIII IIII Hill ILElIvAIEFI _ REMOVE CENTER WALL PIER J Q C� z C 0 m U � (n � W Lu 0 d EXISTING DEMO ELEVATION 1 N SCALE: 1/4" = V-0" Q O T-0" 0 2'-0" 4'-0" N Y Q DESIGN: MDR DRAWN: JEG CHECK: DMT JOB NO: 23344.10 DATE: 1 2/01 /23 v Z 0 Q > Ld LLJ v J 1111 0 RELOCATE GUTTER DOWNSPOUT 0 0 0 VERTICAL CEDAR SIDING Ll Ll Z N TO MATCH EXISTING El ElW W 00 � U > Z EXPOSED CONCRETE 1::] El LEI Q 0 0 0�_ �:: LEIDEW N �jo z Y�Z NEW SINGLE GARAGE DOOR cy— 0 V / H M 0 X () � W LW � U- SHEET: RECEIVED Dec 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROPOSED ELEVATION Alm 2 SCALE: 1/4" = V-0" 2'-0" 0 2'-0" 4'-0" STRUCTURAL NOTES (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) CODE MINIMUM LAPS AND EMBEDMENT GALVANIZATION ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION. SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. DESIGN LOADS DEAD LOADS: ROOF 15 PSF FLOOR 15 PSF LIVE LOADS: ROOF (SNOW LOAD) 25 PSF FLOOR 40 PSF (LIVE LOADS ARE REDUCED WHERE PERMISSIBLE PER IBC SECTION 1607.11). EARTHQUAKE LOADS: EQUIVALENT LATERAL FORCE PROCEDURE PER ASCE 7-16 SECTION 12.8. SITE CLASS D (DEFAULT) SHORT PERIOD SPECTRAL RESPONSE ACCEL (SS) 1.287 ONE SECOND SPECTRAL RESPONSE ACCEL (SI) 0.453 SHORT PERIOD DESIGN SPECTRAL RESPONSE ACCEL (SDS) 0.837 ONE SECOND DESIGN SPECTRAL RESPONSE ACCEL (SDI) 0.558 RISK CATEGORY II SEISMIC IMPORTANCE FACTOR (IF) 1.0 SEISMIC DESIGN CATEGORY D BASIC SEISMIC FORCE -RESISTING -SYSTEM WOOD SHEAR WALLS RESPONSE MODIFICATION FACTOR, (R) 6.5 REDUNDANCY FACTOR (p) 1.0 SEISMIC RESPONSE COEFFICIENT (CS) 0.158 W = TOTAL SEISMIC DEAD LOAD AS DEFINED PER ASCE 7-16 SECTION 12.7.2. SS BASE SHEAR (V), V = CSW = IDWW WIND LOADS: BASIC WIND SPEED (3 SECOND GUST) 97 MPH EXPOSURE D KzT 1.0 SEE PLANS FOR ADDITIONAL DESIGN LOADS. STATEMENT OF SPECIAL INSPECTIONS SPECIAL INSPECTIONS ARE REQUIRED AS INDICATED IN THE FOLLOWING TABLE. THE CONTRACTOR SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF WORK IN ACCORDANCE WITH SECTION 1704.4 OF THE IBC. STRUCTURAL OBSERVATION OF THE STRUCTURAL SYSTEM BY THE ENGINEER IS NOT REQUIRED. FREQUENCY AND DISTRIBUTION OF REPORTS - INSPECTION REPORTS SHALL BE PROVIDED FOR EACH DAY ON SITE BY SPECIAL INSPECTOR. STRUCTURAL OBSERVATION REPORTS SHALL BE PROVIDED AFTER EACH OBSERVATION. REPORTS SHALL BE DISTRIBUTED TO THE CONTRACTOR, ARCHITECT, ENGINEER AND BUILDING OFFICIAL. SPECIAL INSPECTION OPERATION CONT PERIODIC REMARKS CONCRETE ADHESIVE ANCHORS X IF USED NOTE: ALL ITEMS MARKED WITH AN "X" SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17. SPECIAL INSPECTION SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE OWNER. THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL SHALL BE FURNISHED WITH COPIES OF ALL RESULTS. ANY INSPECTION FAILING TO MEET THE PROJECT SPECIFICATIONS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE DESIGN TEAM. CONCRETE ALL CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH CHAPTER 26 OF ACI 318 AND THE AMERICAN CONCRETE INSTITUTE'S SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301). ALL CONCRETE SHALL BE STONE -AGGREGATE CONCRETE HAVING A UNIT WEIGHT OF APPROXIMATELY 150 POUNDS PER CUBIC FOOT. CONCRETE STRENGTHS AT 28 DAYS (fc) AND MIX CRITERIA SHALL BE AS FOLLOWS: MAXIMUM MIN CEMENT TYPE OF CONSTRUCTION f'c* WATER/CEMENT CONTENT PER CUBIC MAXIMUM SHRINKAGE STRAIN RATIO YARD SLABS ON GRADE 3000 PSI 0.55 5 1/2 SACK N/A FOOTINGS 3000 PSI 0.55 5 1/2 SACK N/A WALLS 4000 PSI 0.45 5 1/2 SACK N/A THE MINIMUM AMOUNT OF CEMENT LISTED ABOVE MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH CHAPTER 26 OF ACI 318. ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR -ENTRAINED IN ACCORDANCE WITH ACI 318 TABLE 19.3.3.1 FOR MODERATE EXPOSURE CLASS F1. *PROVIDE f'c SPECIFIED IN TABLE FOR DURABILITY REQUIREMENTS. 2500 PSI CONCRETE MEETS STRENGTH REQUIREMENTS, THEREFORE SPECIAL INSPECTION IS NOT REQUIRED. REINFORCING STEEL REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615, AND SHALL BE GRADE 60 (Fy = 60,000 PSI), UNLESS NOTED OTHERWISE. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615 MAY BE WELDED IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D1.4 ARE SUBMITTED. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. PROVIDE WELDED WIRE FABRIC IN SHEETS NOT ROLLS. LAP WELDED WIRE FABRIC 12" AT SIDES AND ENDS. REINFORCING STEEL SHALL BE DETAILED INCLUDING HOOKS AND BENDS IN ACCORDANCE WITH ACI SP-66 AND ACI 318, LATEST EDITIONS. UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE PER SCHEDULE. MECHANICAL SPLICING OF REINFORCING BARS, WHERE INDICATED ON THE DRAWINGS, SHALL BE BY AN ICBO APPROVED SYSTEM, SHALL DEVELOP 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR, AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET -SETTING EMBEDDED ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. REFER TO CHAPTER 25 OF ACI 318 FOR OTHER REINFORCING STEEL REQUIREMENTS. UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE AS TABULATED BELOW: f'c = 3000 PSI DEVELOPMENT LENGTH LAP SPLICE BAR TENSION COMPRESSION TENSION COMPRESSION SIZE TOP BARS OTHER BARS ALL BARS TOP BARS OTHER BARS ALL BARS #3 22 17 9 28 22 12 #4 29 22 11 37 29 15 #5 36 28 14 47 36 19 #6 43 33 17 56 43 23 #7 63 48 20 81 63 27 #8 72 55 22 93 72 30 NOTE: 1. ALL LENGTHS ARE IN INCHES. 2. ALL LAP SPLICES ARE CLASS B. 3. "TOP BARS" ARE HORIZONTAL REINFORCEMENT PLACED SUCH THAT MORE THAN 12 INCHES OF CONCRETE IS CAST IN THE MEMBER BELOW THE BAR. CONCRETE COVER ON REINFORCING CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" CONCRETE EXPOSED TO EARTH AND WEATHER: #6 BARS AND LARGER 2" #5 BARS AND SMALLER 1 1/2" CONCRETE NOT EXPOSED TO EARTH OR WEATHER: SLABS, WALLS AND JOISTS 3/4" COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1 1/2" CONCRETE GENERAL NOTES VERTICAL BARS SHALL START FROM TOP OF FOOTING. HORIZONTAL BARS SHALL START A DISTANCE OF 1/2 THE NORMAL BAR SPACING FROM TOP OF FOOTING AND TOP OF FRAMED SLABS. IN ADDITION, THERE SHALL BE A HORIZONTAL BAR AT A MAXIMUM OF 3" FROM TOP OF WALL AND BOTTOM OF FRAMED SLABS. PROVIDE CORNER BARS TO MATCH THE HORIZONTAL REINFORCING WITH TENSION LAP SPLICE AT EACH SIDE PER TABLE, OR BEND ONE SIDE OVER TO PROVIDE TENSION LAP. PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS ON GRADE TO BREAK UP SLAB INTO RECTANGULAR AREAS OF NOT MORE THAN 400 SQUARE FEET EACH. AREAS TO BE AS SQUARE AS PRACTICAL AND HAVE NO ACUTE ANGLES. JOINT LOCATIONS TO BE APPROVED BY THE ARCHITECT. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED BEYOND JOINT. SEE ARCHITECTURAL DRAWINGS AND MECHANICAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF OPENINGS IN CONCRETE WALLS, FLOORS AND ROOF. UNLESS INDICATED OTHERWISE, REINFORCE AROUND OPENINGS GREATER THAN 12" IN EITHER DIRECTION WITH (2) #5 EACH SIDE AND (1) #5 x 4'-0" DIAGONAL AT EACH CORNER. EXTEND BARS T-0" BEYOND EDGE OF OPENING. IF T-0" IS UNAVAILABLE, EXTEND AS FAR AS POSSIBLE AND HOOK. HOOK ALL REINFORCING INTERRUPTED BY OPENINGS. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE AND OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES. PROVIDE 3/4" CHAMFER AT ALL CORNERS EXCEPT AS NOTED. LUMBER ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fc (PSI) SLEEPERS DOUG-FIR STUD 700 - LIGHT FRAMING (STUDS) HEM -FIR STUD 675 800 2x JOISTS AND PLANKS HEM -FIR #2 850 - PLATES AND BLOCKING HEM -FIR #2 850 - 6x AND LARGER BEAMS AND STRINGERS DOUG-FIR #2 875 - 4x AND SMALLER BEAMS AND STRINGERS HEM -FIR #2 850 - ALL POSTS AND TIMBERS DOUG-FIR #1 1200 1000 REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1. NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: NAIL SHANK 0 MIN LENGTH 8d COMMON 0.1310 2 1/2" SHANK 10d COMMON 0.1480 3" SHANK 12d COMMON 0.1480 3 1/4" SHANK 16d COMMON 0.1620 3 1/2" SHANK 10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148" 0 x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE SHANK AND THREADED PORTIONS PER NDS 12.1.4.2. CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS, SCREWS, OR BOLTS IN EACH MEMBER. INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED ACCORDING TO THE FOLLOWING TABLE: GALVANIZATION UNTREATED WOOD CCA-C SBX ACQ-C ACQ-D CBA-A CA-B OTHER BORATE ACZA OTHER PT WOOD G90 X X X G 185 X X X X X X HDG X X X X X X STT300 X X X X X X X X G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA HDG = HOT DIP GALVANIZED SST300 = TYPE 316L STAINLESS STEEL RATED SHEATHING RATED SHEATHING SHALL BE GRADE C-D INT-APA WITH EXTERIOR GLUE OR OSB SHEATHING WITH EXTERIOR GLUE IN CONFORMANCE WITH IBC STANDARD 2303.1.5. TIMBERSTRAND, MICROLLAM, AND PARALLAM MEMBERS FABRICATED IN CONFORMANCE WITH THE INTERNATIONAL CODE COUNCIL EVALUATION SERVICE (ICC-ES) REPORT NO. ESR-1387 OR CCMC REPORT NO. 12627-R, 08675-R, AND 11161-R. EACH MEMBER SHALL BE IDENTIFIED BY A STAMP INDICATING THE PRODUCT TYPE AND GRADE, ICC-ES OR CCMC REPORT NUMBER, MANUFACTURER'S NAME, PLANT NUMBER AND INDEPENDENT INSPECTION AGENCY'S LOGO. FABRICATOR SHALL BE CERTIFIED. MEMBERS SHALL MEET THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fv (PSI Fc (PSI) BEAMS & POSTS (d < 9 1/2") LSL 1.3E 1,700 425 1,835 RIMS & BEAMS (d >_ 9 1/2") LSL 1.55E 2,325 310 - BEAMS & POSTS LVL 2.0E 2,600 285 2,510 POSTS (d < 9 1/2") PSL 1.8E 2,400 190 2,500 BEAMS (d >_ 9 1/2") PSL 2.0E 2,900 290 - TIMBERSTRAND, MICROLLAM, AND UNTREATED PARALLAM MEMBERS ARE INTENDED FOR DRY -USE APPLICATIONS. UNLESS NOTED OTHERWISE, ENGINEERED WOOD BEAMS EXPOSED TO WEATHER SHALL BE TREATED PER MANUFACTURES RECOMMENDATIONS. TYPICAL FRAMING NOTES 2x STUDS @ 16" OC FOR ALL SHEAR AND/OR BEARING WALLS UNO. REFER TO FRAMING PLAN NOTES FOR TYPICAL DOOR & WINDOW HEADERS NOT CALLED OUT ON THE PLANS. HEADERS SHALL BE SUPPORTED BY A MINIMUM OF (1) CRIPPLE AND (1) FULL HEIGHT STUD UNO. COLUMNS BELOW FLUSH MULTIPLE JOIST BEAMS SHALL BE EQUAL IN WIDTH TO THE BEAM. ALL COLUMNS NOT CALLED OUT OTHERWISE SHALL BE TWO STUDS. 2. WALL BASE PLATE ON CONCRETE WALL PLATES BEARING ON CONCRETE SHALL BE PRESSURE -TREATED. FOR ALL EXTERIOR AND INTERIOR WALLS, BOLT PLATES OR SILLS TO CONCRETE STEM WALLS OR THICKENED SLAB FOOTINGS WITH 5/8 INCH DIAMETER ANCHOR BOLTS WITH 7 INCH MINIMUM EMBEDMENT. PLACE AT 5'-0" OC MAXIMUM FOR SHEAR WALLS, AND AT 6'-0" OC FOR BEARING WALLS AND OTHER PARTITIONS. USE MINIMUM OF TWO ANCHOR BOLTS PER SILL AND PLACE ONE WITHIN 12 INCHES OF END OF PLATES, TYPICAL UNLESS NOTED OR DETAILED OTHERWISE. REFER TO SHEAR WALL SCHEDULE. AT ALL SILL PLATE ANCHOR BOLTS, CONTRACTOR SHALL INSTALL 1/4" x 3" x 3" FLAT PLATE WASHERS. INTERIOR NON-STRUCTURAL WALLS MAY BE ANCHORED TO CONCRETE SLAB -ON -GRADE WITH 1/4" x 3" POWDER ACTUATED FASTENERS WITH 3/4" WASHERS AT 16" OC AND WITHIN 6" OF END OF PLATES. 3. ROOF AND FLOOR FRAMING PROVIDE 1 1/2" FULL DEPTH BLOCKING FOR JOISTS AND RAFTERS AT ALL SUPPORTS AND AT 8'-0" OC MAXIMUM UNO. INTERMEDIATE 8'-0" OC BLOCKING NOT REQ'D IF GWB CEILING IS INSTALLED DIRECTLY TO UNDERSIDE OF FRAMING. INSTALL DOUBLE JOISTS UNDER PARTITIONS EXTENDING ONE HALF OR MORE OF THE JOIST SPAN. PROVIDE TRUSS BLOCKING PANELS FOR ROOF TRUSSES AT SUPPORTS AND SHEAR WALLS, AND WHERE INDICATED ON PLANS AND DETAILS. 4. DIAPHRAGM NAILING ALL SHEAR WALLS, FLOOR AND ROOF DIAPHRAGM NAILINGS SHALL BE AS CALLED OUT ON SCHEDULES OR ON THE PLANS. EXTERIOR WALLS NOT INDICATED AS SHEAR WALLS SHALL BE SHEATHED AND NAILED TO SUPPORTING FRAMING WITH 8d NAILS AT 6" OC AT ALL PANEL EDGES AND 12" OC AT ALL INTERMEDIATE SUPPORTS. THE USE OF NAIL GUNS WILL BE APPROVED IF NAILING INTO THE DIAPHRAGMS CAN BE INSTALLED FLUSH WITH FACE OF SHEATHING. NAIL PENETRATIONS GREATER THAN 1/16" ARE NOT ACCEPTABLE. 5. ALLOWABLE STUD AND PLATE PENETRATIONS CUTTING AND/OR NOTCHING OF WOOD STUDS OR PLATES SHALL NOT EXCEED 25% OF THE STUD/PLATE WIDTH IN EXTERIOR AND BEARING WALLS AND SHALL NOT EXCEED 40% OF THE STUD/PLATE WIDTH IN ANY NON -BEARING PARTITIONS. BORED HOLE DIAMETER IS LIMITED TO 40% OF STUD/PLATE WIDTH IN ANY STUD AND MAY BE 60% IN NONBEARING PARTITIONS OR IF STUD IS DOUBLED. MAINTAIN 5/8" MINIMUM EDGE DISTANCE FROM HOLE EDGE. 6. GYPSUM WALLBOARD NAILING ALL GYPSUM WALLBOARD SHALL BE NAILED TO ALL STUDS AND TOP AND BOTTOM PLATES WITH 6d COOLER NAILS OR NO. 13 GAUGE x 1 5/8" @ 7" OC (5d COOLER NAILS FOR 1/2 INCH GYPSUM SHEATHING). TYPICAL UNLESS NOTED OTHERWISE. INSTALLATION OF GWB SHALL BE SUCH THAT JOINTS ARE STAGGERED ON EACH SIDE OF A SINGLE WALL. EXISTING BUILDING CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. LEGEND DEFINITION SYMBOL DEFINITION SYMBOL DIRECTION OF FRAMING wl NATIVE SOIL==�=�=� - - - - - EXTENT OF FRAMING 0.1 GRANULAR FILL STRUCTURAL STEEL COLUMNS P COLUMN BEARING RATED SHEATHING ON BEAM BEAM CONTINUOUS SHEAR WALL OVER SUPPORT (SEE SCHEDULE) SWX COLUMN MARK G� CONCRETE WALL (SEE SCHEDULE) / BEARING STUD FOOTING MARK O WALL (SEE SCHEDULE) NON -BEARING t HOLDOWN MARK STUD WALL (SEE SCHEDULE) BEARING STUD HANGER MARK O SHEAR WALL vvy (SEE SCHEDULE) NON -BEARING FLAG NOTE STUD SHEAR WALL (SEE PLAN NOTES) CMU WALL STEEL MOMENT Exxxm /_ �V FRAME CONN. ABBREVIATIONS (A) ABOVE ANCHOR BOLT ALTERNATE ARCHITECT BELOW BLOCKING HORIZ HORIZONTAL KING POST KIPS PER SQUARE INCH AB ALT KIP KSI ARCH (B) BLKG MECH MECHANICAL MOMENT FRAME NEAR SIDE MF NS BM BOT BEAM BOTTOM OC ON CENTER OPPOSITE PLATE PLACES POUNDS PER SQUARE INCH POUNDS PER SQUARE FOOT OPP BTWN BETWEEN COMPLETE JOINT PENETRATION PL CJP PLCS CLR CLEAR CONCRETE MASONRY UNIT PSI CMU PSF COL COLUMN P/T POSTTENSIONED CONC CONCRETE PT PRESSURE TREATED CONN CONNECTION REINF REINFORCING CONT CONTINUOUS REQ'D REQUIRED DBL DET DOUBLE DETAIL SCHED SIM SCHEDULE SIMILAR SLAB ON GRADE STANDARD SHEAR WALL TOP OF CONCRETE TOP OF STEEL TOP OF WALL TYPICAL UNLESS NOTED OTHERWISE DIM DIMENSION SOG EA EACH STD ELEV ELEVATION SW EXIST EXISTING TOC EXP FLR EXPANSION TOS FLOOR TOW FDN FTG FOUNDATION FOOTING FAR SIDE FULL HEIGHT GLUE -LAMINATED BEAM TYP LINO FS VFY VERIFY VERIFY IN FIELD VERTICAL FH VIF GLB VERT C G ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 12/ 01/ 23 ols DESIGN: MDR DRAWN: JEG CHECK: DMT JOB NO: 23344.10 DATE: 1 2/01 /23 V / W ~ O O Z N O Z W W 00 J Z W Q a < �. �:: Q. W N z w o U CY Y D cy- M O w Q V) W z SHEET: RECEIVED Dec 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT C GI ROOF FRAMING PLAN SCALE: 1/4" = V-0" ROOF FRAMING PLAN NOTES 1. CONTRACTOR TO VERIFY TEMPORARY SHORE AND SUPPORT EXIST FRAMING AS REQUIRED. NOTE: 2x OR 3x BLOCKING ONLY IF STAGGER SHEATHING AS SHOWN. BLOCKED DIAPHRAGM IS SPECIFIED FRAMING MEMBERS INTERMEDIATE W/ SPACING PER PLAN FRAMING MEMBERS SHEATHING PANEL, TYP II II I I CONTINUOUS JN� I 1 11 ILS IN PANEL EDGES I I I I I I I I AA ROW ARE DJACENT ATO BE DRIVEN FROM OPPOSITE SIDES, TYP SUPPORTED PANEL EDGES II II I II II II II II _ II J L II _ II _ II _JL_J� DIAPHRAGM BOUNDARY (SHEAR WALL, BEAM, OR DRAG STRUT) TYPICAL FLOOR/ ROOF SHEATHING DETAIL Ze h) 3 1/2" x 117/8" PSL 2'-0" 0 FOR 2x4 STUDS, PROVIDE SINGLE ROW OF NAILS STAGGERED EA SIDE WITH 1 1/2" EDGE DISTANCE. FOR 2x6 STUDS, PROVIDE (2) ROWS OF NAILS SPACED AT 2 1/2" W/ 1 1/2" EDGE DISTANCE 9" OC MAX SPACING BETWEEN ADJACENT NAILS IN A ROW 0.131"0 x 3" NAILS, TYP (5) STUDS MAX TO BE USED FOR BUILT-UP COLUMNS TYPICAL BUILT-UP STUD COLUMN DETAIL 2'-0" 4'-0" MST27 STRAPS, EA END HEADER PER PLAN e PER PLAN x Q 0 10d NAILS @ 3" OC, TYP HOLDOWN PER PLAN, TYP .I I I I. 5/8" 0 ANCHOR BOLT W/ °I I° 3x3x1/4 PLATE WASHER Ie ^I el Ie 5/8"0 THREADED ROD �'— . --- -- W/ NUT & WASHER � � I I I I II II I 3 I I _ I II II I I I I I I I I I I 1�--------------- CONVENTIONAL SHEAR WALL 10d NAILS @ 3" OC EA WAY STAGGERED 2x6 FLAT BLOCKING AT ANY PLYWOOD JOINTS, JOINTS MUST BE LOCATED WITHIN 24" OF MID HEIGHT I II I II I II I II I II I II I II I II I II I II I f——M I II I II I II I II I II I II I II I II SLENDER SHEAR WALL ELEVATION SCALE: 1/2" = V-0" EDGE NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP 0.131"0 x 3" NAILS @ 9" OC (2) ROWS OF 0.131" 0 x 3" NAILS @ 9" OC STUD WALL PER FRAMING PLAN NOTES, TYP EDGE NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP SHEATHING (OR GWB) AND NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP A. CORNER INTERSECTION B. 'T' INTERSECTION TYPICAL WALL INTERSECTION DETAIL 2x6 STUD @ 2x4 CROSS WALL 2x8 STUD @ 2x6 CROSS WALL EDGE NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP 0.131"0 x 3" NAILS @ 9" OC STUD WALL PER FRAMING PLAN NOTES, TYP SHEATHING (OR GWB) AND NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP #3 TIES 00 h L #4 VERT SECTION A -A PER PLAN 1WN PER PLAN PIES TOP @6"OC ,T @ 6" OC EXIST FOUNDATION WALL DOWEL & EPDXY REINF INTO EXIST FOUNDATION W/ SIMPSON SET-XP & 12" MIN EMBED DETAIL SCALE: 1" = V-0" Holes to be drilled, blown, brushed and cleaned at the time of inspection. Epoxy to be on -site for verification. SECTION I I I I I I I I I I I I �L EXIST PARAPET BEAM PER PLAN ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 12/01/ 23 J H I— Z O m r ~ O V) ry- W w 0 a m w Q O C) ---, N c-I Y Q DESIGN: MDR DRAWN: JEG CHECK: DMT JOB NO: 23344.10 DATE: 1 2/01 /23 Q W 0 Z Q Z O ^ L1 W W 00 J Z w Q a < Lj z o U CY Y D CY— M 0 M w Q SHEET: RECEIVED WALL BEYOND Dec 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT S 01 SCALE: NTS SCALE: 1" = V-0" SCALE: 1" = V-0" SCALE: 1" = V-0"