Loading...
REVIEWED BLD RESUB 1-BLD2024-0863+Structural_Analysis_or_Calculations+10.21.2024_7.02.57_PM+4572735BLD2024-0863 RESUB Oct 22 2024 _ Structural Design Associates Engineering Slruclures to Last Sept. 27, 2024 Soledad Guererro 9138 186" PL SW Edmonds, WA 98026 Subject: Alternate Holdown SDA Ref. # 10035 To whom this may concern: SDA 410035 ............................................. REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT ............................................... At the request of Mark Trembach this office reviewed the subject project regarding an alternative to the through bolt HDU4 holdown. An alternative to the HDU4 (THROUGH) shown on the plans is a MSTCM60 with (20) 12d common nails (strap to 4x6 DF No.2 post) and (14) 11/4" diameter x 1 1/4" long Titen Turbo Hex head screws (strap to stem wall). A small portion of the footing will need to be removed to allow placement of the strap. Special care must be taken during removal to keep the bearing surface of the strap in line with the stem wall. Please see the attached schedule and detail showing the alternate connection. Please contact this office if you have any questions concerning this letter, or for any other assistance. Sincerely, Z�4 -'0�4 --- Chris Lalonde, E.I.T. Chris Covington, P.E. 3006 Ruckcr Ave. Everett, WC 98201 Ph: 425-339-0293 Fax: 425-252-0916 sdaeverett.com Structural Design Associates Engineering Structures to Last SDA 410035 HOLDOWN SCHEDULE *FOR HOLDOWNS INSTALLED IN EXISTING 6" WIDE STEM THRU BOLTS OR EMBEDMENT MINIMUM MODEL ANCHOR BOLT NAILS/SCREWS / STRAP EDGE DIST. LENGTH (20) 12d COMMON IN OF TOP TITEN TURBO MSTCM60 N/A 46 ABOVE & (14) 59Y2 SCREW 1h" DOWN (EXPANSION) A"00-%" 11TEN TURBO HEX FROM TOP OF HEAD SCREWS I STEM HOLDOWN NOTES 1. ALL —THREAD BOLTS SHALL CONFORM TO ASTM A307 2. MINIMUM CONCRETE COMPRESSIVE STRENGTH f c-2500 PSI. MINIMUM WALL THICKNESS IS 6". 3. ALL HOLDOWNS REQUIRE A (2) 2x POST UNLESS NOTED OTHERWISE. WHERE HOLDOWNS ARE INSTALLED INTO THE WIDE FACE OF THE STUD, THE STUDS MUST BE STITCH NAILED TOGETHER W/ 16d SINKERS STAGGERED O 4" 0/C. 4. MINIMUM EDGE DISTANCE IS FOR FORMED CONCRETE EXPOSED TO WEATHER OR SOIL FOR CONCRETE CAST AGAINST SOIL PROVIDE 3" CLEAR TO ANCHOR BOLT. 5. NALS/SCREWS TO HOLDOWN POST SHALL BE PER MANUFACTURER'S SPECIFICATIONS. 6. WHEN FIELD CONDITION BECOME LESS THAN MINIMUM SHOWN, CONTACT ENGINEER PRIOR TO PROCEEDING. 7. ALL HOLDOWN BOLTS MUST BE RE —TIGHTENED JUST PRIOR TO ENCLOSING SECOND SIDE OF WALL. 8. LONGER STRAPS MAY BE REQUIRED FOR EXPANSION ANCHORS DEPENDING ON FLOOR FRAMING THICKNESS. WHERE A SMALLER MST STRAP IS SPECIFIED, A LARGER MST STRAP MAY BE USED (EX. MST 37 =_> MST 60). ONLY SPECIFIED FASTENERS ARE REQUIRED. STRAPER-If",..", [fil :'LAN NAILS PER SCHEDULE VIN. 4x6 DF No 2 OR PER PLAN SOLID BLOCKING DIRECTLY UNDER POST PROTECT SCREWS & STRAP RIM JOIST WITH (2) COATS OF: APOC AP576 ETERNA—KOTE FLAT ROOF SILICONE COATING, INSTALL PER MFR SPECS. ALT: HENRY TROPI—COOL SCREWS 887 ROOF COATING PER SCHEDULE EXISTING FOUNDATION EXPAN IC)N ANC/H0R HC)LPOWN w/ RIM 3006 Rucker Ave. Everett, V,'A 98201 Ph: 425-339-0293 Tax: 425-252-0916 sdaeverett.com Titen Turbo w/ MSTAM / MSTCM Strap (Ductile Design LRFD) Date: 9/27/2024 Engineer: CRL Job:10035 REAR LRFD Holdown w/o Do Demand Capacity Connection Design: Strap per Simpson 4471 5692 lbs. 79% P 4471 lbs. Titen Turbo 4471 5692 lbs. 79% Z 105 lbs. Ta. 12P Nos Fasteners (NDS) 4471 4533 lbs. 99% Z' 227 lbs. Strap Per AISC 4471 5832 lbs. 77% Kf 3.32 2 0.50 # Titen Turbo 1/4" x 1 3/4" Hex 14 14 CM 1 Ct 1 Simpson # of Fasteners: 20 MSTCM60 Cg 1.00 NDS 2018 # of Fasteners: 20 20 n Model No. Fasteners: Capacity: Screws: REA MSTAM24 7 1956 5 Es 29000000 psi MSTAM36 14 2522 8 .148"(D Em 1600000 psi MSTCM40 26 5692 14 x3.25" As 0.29 in^2 MSTCM60 20 5692 14 Nails Am 10.5 in^2 m 0.94 1.00 Component Strength u (LRFD) Limit: s 1.5 in Titen-HD 5x3.75 1 0 Conc. Breakout v 15373 (6" down from top of (6") wall ) Limit: T-Yielding T-Rupture Bearing Tearout D 0.148 in MSTCM Strap Fasteners: (LRFD) (kips) CA 1 5.832 Ceg 1 5.873 Cdi 1 14 21.924 Ctn 1 16.443 m 0.7 A 1 D2: (a) Tensile Yielding of Strap: (�t 0.9 Pn Fy*Ag Fy 36 ksi Ag 0.18 in^2 (�tPn 5.832 kips (b) Tensile Rupture of Strap: �t 0.75 Pn Fu*Ae Fu 58 ksi Ae 0.135 in^2 (�tPn 5.873 kips (1) (2) Rn d t Fu 4)Rn Rn Ic t Fu (ORn J3.10 0.75 Bearing Tearout @ Bolt: 2.4*d*t*Fu 0.25 in 0.06 in 58 ksi 1.566 kips/Screw @ Bolt: 1.2*lc*t*Fu 0.375 in 0.06 in 58 ksi 1.175 kips/Screw