REVIEWED BLD2024-0001+Structural_REPORT+12.30.2023_12.51.39_PM+3976568RECEIVED Jan 03 2024 PACIFIC NORTHWEST INSPECTION ENGINEERS CITY OF EDMONDS 10738 169th Avenue S.E., Renton, Washington 98059 (425)228-5975 DEVELOPMENT SERVICES DEPARTMENT BLD2024-0001 BUILDING INSPECTION REPORT December 21, 2023 Engineer's Inspection of the Real Property Located at 10031 240th Place SW Edmonds, Washington For the exclusive use of Date of Inspection: Inspecting Engineer: INTRODUCTION Alex Pi December 21, 2023 Jack A. Swardz, P.E. REVIEWED BY CITY OF EDMONDS The purpose of this inspection was to evaluate structural issues, as noted, to the extent that a reasonable amount of time and conditions permit. The initial presumption is that all elements are adequate and proper. Statements, representations or conclusions to the contrary are made only when the inspecting engineer sees evidence which, in his judgment, indicates the existence of significant deficiencies. The inspection is visual only and does not involve the opening or exposure of elements concealed from view. Wherever a deficiency of any kind is identified in this report, there is always a possibility that it is associated with a larger, more serious, or more extensive problem that is hidden from view or is beyond the scope of this inspection. Consequently, you should take whatever action is necessary to ensure that the full extent and implications of identified deficiencies are known. To fully understand the importance of any deficiency, you should obtain bids for its correction. Bids for repairs vary widely. You should always obtain at least three competitive bids. Certain limitations apply to any inspection, including those diligently performed by a qualified expert. The limitations on this inspection include any noted in the body of the report together with those listed under "Limitations on Inspections" at the end of the report. We consider these limitations unavoidable. If you make any use of the information contained in this report, it is necessary that you understand and accept these limitations. IF THESE LIMITATIONS ARE UNACCEPTABLE TO YOU, YOU SHOULD NOT RELY ON THE INFORMATION IN THIS REPORT FOR ANY PURPOSE WHATSOEVER. Consulting at 10031 240"' Place SW, Edmonds, Washington EVALUATIONS There is a significant sag in the ridge of the roof, over the old garage area. There is a significant risk of additional structural damage if the deficiency is not corrected. The problems will more likely occur during a period of heavy snow on the roof. The span of the ridge over the old garage area is about 21 feet. I recommend that you install a Laminated Wood Beam, 3-1/2xl6-1/2 in the attic to support the ridge. I also recommend that you tie the ceiling joists up to the GluLam with Simpson H2.5 Hurricane Clips or similar devices. The G1uLam will be supported down to the house foundation with 4x4 wood posts. We also discussed modifying interior walls. The walls that are parallel to the rafter system, above, are not structural and can be modified. If the walls are perpendicular to the rafters, some additional support may need to be made along with the wall modification. LIMITATIONS ON INSPECTIONS The limitations on this inspection include those discussed throughout the report, together with those listed in the following paragraphs. ACCESSIBILITY OF DEFICIENCIES: Statements, representations, or conclusions offered by the engineer who conducts the inspection and/or by Pacific Northwest Inspection Engineers are based solely upon a visual examination of the exposed areas of the structure inspected. Hidden defects could have a significant impact on the visually based conclusions, statements, and representations made by the inspector. NO WARRANTY: All statements, representations, or conclusions offered by the inspecting engineer are the considered opinion of the inspecting engineer arising from the limited inspection described herein. These statements, representations, or conclusions do not constitute an express or implied warranty of any kind. 12/30/2023 Page 2 of 2