Loading...
REVIEWED RESUB 1 BLD2023-0343+Structural_Analysis_or_Calculations+4.7.2023_11.27.54_AM+3469922Project: BAUDER REMODEL BLD2023-0343 Location: C 2(Pipe coolumn 2 inch dia) Column Column [2015 International Building Code(AISC 9th Ed ASD - ACI 318-14)] Pipe 2 Std. x 7.1 FT /ASTM A53-GR.B Section Adequate By: 40.2% VERTICAL REACTIONS Live Load: Vert-LL-Rxn = 4337 lb Dead Load: Vert-DL-Rxn = 2579 lb Total Load: Vert-TL-Rxn = 6916 lb COLUMN DATA Total Column Length: 7.1 ft Unbraced Length (X-Axis) Lx: 7.1 ft Unbraced Length (Y-Axis) Ly: 7.1 ft Column End Condition-K (e): 1 COLUMN PROPERTIES Pipe 2 Std. -Round Steel Yield Strength: Fy = 35 ksi Modulus of Elasticity: E = 29000 ksi Column Section: dx = 2.38 in Column Wall Thickness: t = 0.143 in Area: A = 1 in Moment of Inertia (deflection): Ix = 0.63 in4 Section Modulus: Sx = 0.53 in' Plastic Section Modulus: Zx = 0.71 in- Rad. of Gyration: rx = 0.79 in Column Compression Calculations: KL/r Ratio: KLx/rx = 107.71 Controlling Direction for Compr. Calcs: (Y-Y Axis) Flexural Buckling Stress: Fcr = 19.33 ksi Controlling Equation F8-1 Nominal Compressive Strength: Pc = 12 kip Combined Stress Calculations: H1-1a Controls : 0.60 Controlling Combined Stress Factor: 0.6 dy = 2.38 in ly = 0.63 in4 Sy = 0.53 in3 Zy = 0.71 in3 ry = 0.79 in KLy/ry = 107.71 1 of 3 BASRI BASRI B2 ENGINEERS of StruCalc Version 11.1.2.0 3/16/2023 12:28:50 PM LOADING DIAGRAM r P roe wasy�ryS,Q 1 cT B w �G 43789 a�(� (vQ" ��'C CrURAL ENG\ ��� 4 �SS ONAL ..,.,.,.,. REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT; 7.1 ft A AXIAL LOADING Live Load: PL = 4337 lb * Dead Load: PD = 2553 lb * Column Self Weight: CSW = 26 lb Total Axial Load: PT = 6916 lb * Load obtained from Load Tracker. See Summary Report for details. ................................................. REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT RESUB Apr 07 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Project: BAUDER REMODEL Location: FTG1 Footing Footing [2015 International Building Code(2015 NDS)] Footing Size: 2.5 FT x 2.5 FT x 10.00 IN Reinforcement: #5 Bars @ 11.00 IN. O.C. E/W / (3) min. Section Footing Design Adequate FOOTING PROPERTIES Allowable Soil Bearing Pressure: Qs = 1500 psf Concrete Compressive Strength: F'c = 2500 psi Reinforcing Steel Yield Strength: Fy = 40000 psi Concrete Reinforcement Cover: c = 3 in FOOTING SIZE Width: W = 2.5 ft Length: L = 2.5 ft Depth: Depth = 10 in Effective Depth to Top Layer of Steel: d = 6.06 in COLUMN AND BASEPLATE SIZE Column Type: Steel Column Width: m = 2 in Column Depth: n = 2 in Baseplate Width: bsw = 5 in Baseplate Length: bsl = 5 in FOOTING CALCULATIONS Bearing Calculations: Ultimate Bearing Pressure: Qu = 1107 psf Effective Allowable Soil Bearing Pressure: Qe = 1375 psf Required Footing Area: Areq = 5.03 sf Area Provided: A = 6.25 sf Baseplate Bearing: Bearing Required: Bear = 10034 lb Allowable Bearing: Bear -A = 69063 lb Beam Shear Calculations (One Way Shear): Beam Shear: Vu1 = 2404 lb Allowable Beam Shear: Vc1 = 13641 lb Punching Shear Calculations (Two Way Shear): Critical Perimeter: Bo = 38.25 in Punching Shear: Vu2 = 9015 lb Allowable Punching Shear (ACI 11-35): vc2-a = 52175 lb Allowable Punching Shear (ACI 11-36): vc2-b = 72523 lb Allowable Punching Shear (ACI 11-37): vc2-c = 34784 lb Controlling Allowable Punching Shear: vc2 = 34784 lb Bending Calculations: Factored Moment: Mu = 29360 in -lb Nominal Moment Strength: Mn = 191215 in -lb Reinforcement Calculations: Concrete Compressive Block Depth: a = 0.58 in Steel Required Based on Moment: As(1) = 0.14 in2 Min. Code Req'd Reinf. Flex. Members (ACI-150.1): As(2) = 0.91 in2 Controlling Reinforcing Steel: As-reqd = 0.91 in2 Selected Reinforcement: #5's @ 11.0 in. o.c. e/w (3) Min. Reinforcement Area Provided: As = 0.92 in2 Development Length Calculations: Development Length Required: Ld = 15 in Development Length Supplied: Ld-sup = 10.25 in Note: Plain concrete adequate for bending, therefore adequate development length not required 2of3 BASRI BASRI B2 ENGINEERS of StruCalc Version 11.1.2.0 3/16/2023 12:28:51 PM LOADING DIAGRAM F2 in 10 in n n n 3 in t —L 2.s ft FOOTING LOADING Live Load: PL = 4337 lb' Dead Load: PD = 2579 lb Total Load: PT = 6916 lb Ultimate Factored Load: Pu = 10034 lb Footing plus soil above footing weight: Wt = 503 lb Load obtained from Load Tracker. See Summary Report for details. RESUB Apr 07 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Project: BAUDER REMODEL I 3 of 3 BASRI BASRI / Location: B-1(floor Beam check channel section) B2 ENGINEERS Multi -Span Floor Beam of Multi -Span Floor Beam [2015 International Building Code(AISC 9th Ed ASD - A A36 C8x11.5 x 10.6 FT Section Adequate By: 21.4% Controlling Factor: Moment StruCalc Version 11.1.2.0 3/16/2023 12:28:51 PM DEFLECTIONS Center Live Load 0.18 IN L/699 Dead Load 0.10 in Total Load 0.29 IN L/445 Live Load Deflection Criteria: L/480 Total Load Deflection Criteria: L/360 REACTIONS A B Live Load 2845 lb 2851 lb Dead Load 1629 lb 1632 lb Total Load 4474 lb 4483 lb Bearing Length 0.94 in 0.94 in BEAM DATA Center Span Length 10.6 ft Unbraced Length -Top 0 ft Unbraced Length -Bottom 10.6 ft STEEL PROPERTIES C8x11.5 - A36 Properties: Yield Stress: Fy = 36 ksi Modulus of Elasticity: E = 29000 ksi Depth: d = 8 in Web Thickness: tw = 0.22 in Flange Width: bf = 2.26 in Flange Thickness: tf = 0.39 in Distance to Web Toe of Fillet: k = 0.94 in Moment of Inertia About X-X Axis: Ix = 32.5 in4 Section Modulus About X-X Axis: Sx = 8.14 in3 Plastic Section Modulus About X-X Axis: Zx = 9.63 in3 Design Properties per AISC 14th Edition Steel Manual:ACI 318-19 Flange Buckling Ratio: FBR = 2.9 Allowable Flange Buckling Ratio: AFBR = 10.79 Web Buckling Ratio: WBR = 27.84 Allowable Web Buckling Ratio: AWBR = 106.72 Controlling Unbraced Length: Lb = 0 ft Limiting Unbraced Length - for lateral -torsional buckling: Lp = 2.59 ft Nominal Flexural Strength w/ safety factor: Mn = 17299 ft-lb Controlling Equation: F2-1 Web height to thickness ratio: h/tw = 27.84 Limiting height to thickness ratio for eqn. G2-2: h/tw-limit = 63.58 Cv Factor: Cv = 1 Controlling Equation: G2-3 Nominal Shear Strength w/ safety factor: Vn = 22764 lb Controlling Moment: 14249 ft-lb 5.3 Ft from left support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2 Controlling Shear: -4484 lb 11.0 Ft from left support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s Comparisons with required sections: Read Provided Moment of Inertia (deflection): 26.27 in4 32.5 in4 Moment: 14249 ft-lb 17299 ft-lb Shear: -4484lb 22764lb LOADING DIAGRAM 10.6 ft FLOOR LOADING Center Floor Live Load FILL = 40 psf Floor Dead Load FDL = 15 psf Floor Tributary Width Side One TW 1 = 8.8 ft Floor Tributary Width Side Two TW2 = 1.9 ft Wall Load WALL = 75 plf POINT LOADS - CENTER SPAN Load Number One Live Load 1170 lb Dead Load 647 lb Location 5.33 ft BEAM LOADING Center Reduced Floor Live Load 40 psf Total Live Load 427 plf Total Dead Load 235 plf Beam Self Weight 12 plf Total Load 674 plf RESUB Apr 07 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT