EOR letter for front shear wall1 Structural Design Associates
--� Is'n�rir�eer irr, S'lruc/ru es to last
September 10, 2024
Attn: Telly Willey
Subject: Kitchner Holdown Revision
SDA Ref. # 10077
Dear Terry,
At your request, this office reviewed the subject project to review a holdown alternate for
the front shearwalls of the existing building.
The Simpson HDU4-SDS2.5 may be replaced with (2) Simpson MST37 with (2) '/2-inch
diameter expansion anchors each, with 3 '/2-inch concrete embedment. The top bolt must
be at least 3-inches down from the top of the concrete wall.
Please do not hesitate to contact this office if you have any questions concerning this
letter, or for any further questions.
Sincerely yours,
Chris Covington, P.E.
..I- �.'.../
2802 Rochefcllex Ave Flvcivur , WA 9820*1 Ph: 125- 339 0293 I as: -125 252 0916