Loading...
EOR letter for front shear wall1 Structural Design Associates --� Is'n�rir�eer irr, S'lruc/ru es to last September 10, 2024 Attn: Telly Willey Subject: Kitchner Holdown Revision SDA Ref. # 10077 Dear Terry, At your request, this office reviewed the subject project to review a holdown alternate for the front shearwalls of the existing building. The Simpson HDU4-SDS2.5 may be replaced with (2) Simpson MST37 with (2) '/2-inch diameter expansion anchors each, with 3 '/2-inch concrete embedment. The top bolt must be at least 3-inches down from the top of the concrete wall. Please do not hesitate to contact this office if you have any questions concerning this letter, or for any further questions. Sincerely yours, Chris Covington, P.E. ..I- �.'.../ 2802 Rochefcllex Ave Flvcivur , WA 9820*1 Ph: 125- 339 0293 I as: -125 252 0916 \vww.strucdts.ccnn