APPROVED PLN BLD-BLD2023-0249+Architectural_Plan+2.27.2023_8.28.34_AM+3389102GENERAL NOTES GENERAL REQUIREMENTS ALL WORK SHALL COMPLY WITH THE 2018 EDITION OF THE INTERNATIONAL BUILDING CODE (STRUCTURAL DESIGN), INTERNATIONAL RESIDENTIAL CODE (ORDINANCE), MOST RECENT EDITION OF THE UNIFORM PLUMBING CODE, INTERNATIONAL MECHANICAL CODE, NATIONAL ELECTRIC CODE, WASHINGTON STATE ENERGY CODE, ANY STATE AND LOCAL AMENDMENTS, AND ANY APPLICABLE LAND USE CODE. THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR DEVELOPING CONSTRUCTION DETAILS NECESSARY TO CONSTRUCT A WEATHER TIGHT, DURABLE BUILDING. ALL FLASHING, WEATHERPROOFING, ROOFING AND WATERPROOFING DETAILS AND CONSTRUCTION OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE RESPONSIBILITY OF THE OWNER/BUILDER AND THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER REQUIREMENTS, BUILDING CODE REQUIREMENTS AND ACCEPTED INDUSTRY STANDARDS FOR PERFORMANCE. THE DESIGNER HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION SERVICES OR CONSTRUCTION OBSERVATION SERVICES FOR THIS PROJECT AND IS NOT LIABLE OR RESPONSIBLE FOR DETERMINING ADEQUACY OF CONSTRUCTION OF BUILDING ENVELOPE OR DETAILS. THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR INSPECTING AND VERIFYING THAT ALL FLASHING, WEATHERPROOFING, ROOFING AND WATERPROOFING DETAILS ARE BUILT CORRECTLY AND MEET OWNER/BUILDER'S APPROVAL BEFORE BEING COVERED BY SUBSEQUENT CONSTRUCTION WORK. USE OF THESE PLANS BY ANYONE OTHER THAN THE INTENDED OWNER/BUILDER IS NOT PERMITTED. ANY REDUNDANCY BETWEEN THESE NOTES AND S-SHEETS THE S-SHEETS SHALL SUPERSEDE. SITE WORK 1. NONE MECHANICAL 1. PLUMBING SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT, EXPERIENCED PLUMBER AND IN ACCORDANCE WITH THE UNIFORM PLUMBING CODE AND LOCAL CODES. 2. HVAC SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED MECHANICAL CONTRACTOR IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, 2018 IRC, AND LOCAL CODES. PROVIDE DOCUMENTATION OF FURNACE A.F.U.E. DUCTWORK INSULATION SHALL CONFORM TO THE WASHINGTON STATE ENERGY CODE. WHEN INSTALLED IN GARAGE, HEATING UNITS SHALL BE PLACED SUCH THAT ALL PILOT LIGHTS, BURNERS, HEATING ELEMENTS, OR SWITCHES ARE LOCATED A MIN. OF 18" ABOVE THE GARAGE FLOOR. THERMAL AND MOISTURE 1. INSULATION REQUIREMENTS SHALL MEET OR EXCEED THE LATEST EDITION OF THE WASHINGTON ENERGY CODE OR ENERGY CODE ADOPTED BY THE LOCAL JURISDICTION. INSULATION REQUIREMENTS SHALL BE SHOWN ON PLANS OR ON A SEPARATE ENERGY CALCULATION SHEET. 2. APPLY 1 COAT (MIN) HEAVY BODIED ASPHALT BITUMINOUS DAMPPROFING TO EXTERIOR OF FOUNDATION WALLS, FROM FOOTING TO FINISHED GRADE AT FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE.. (R406.1) 3. APPLY APPROPRIATE WATER REPELLENTS TO ANY MASONRY, CEMENT, PLASTER, OR STUCCO PER MANUFACTURER'S INSTRUCTIONS. 4. PROVIDE 6 MIL BLACK POLYETHYLENE VAPOR BARRIER IN ALL CRAWLSPACE AREAS, LAPPED AT ALL SPLICES AND OVER FOOTINGS. FINISHES GARAGE CEILINGS BENEATH HABITABLE SPACES SHALL BE COVERED WITH 5/8" TYPE "X" GYPSUM WALL BOARD. GARAGE CEILINGS BENEATH ATTIC OR NON LIVING SPACE SHALL BE COVER WITH 5/81, GYPSUM WALL BOARD. WALLS AND STRUCTURE SEPARATING RESIDENTIAL AND GARAGE SPACES SHALL BE COVERED WITH 1/2" GYPSUM WALL BOARD. ALL GARAGE GYPSUM WALLBOARD SHALL HAVE JOINTS FIRETAPED WITH NAILS SET AND COMPOUNDED. ALL OTHER WALLS SHALL RECEIVE 1/2" GYPSUM WALLBOARD. CEILINGS WITH JOISTS/ TRUSS SPACES GREATER THAN 16" SHALL RECEIVE 5/8" GYPSUM WALLBOARD OR 1/2" GYPSUM CEILING BOARD. WALLS SURROUNDING TUBS OR SHOWERS SHALL BE COVERED WITH WATER-RESISTANT GYPSUM WALL BOARD. WATER- PROOF SURFACE TO A HEIGHT OF 72" ABOVE ADJACENT FLOOR. ANY CEMENT PLASTER OR STUCCO SHALL BE INSTALLED IN ACCORDANCE WITH NORTHWEST WALL AND CEILING BUREAU RECOMMENDATIONS FOR MATERIALS, BACKING, LATH, APPLICATION TECHNIQUES, AND FINISHES. ELECTRICAL SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED ELECTRICAL CONTRACTOR IN ACCORDANCE WITH MOST CURENT STATE AND LOCAL ELECTRICAL CODE. ELECTRICAL SCHEMATICS PROVIDED IN THIS SET OF PLANS ARE FOR REFERENCE LAYOUT ONLY. FIRESTOPPING AREA CALCULATIONS HEATED AREAS SQUARE FOOTAGE DECK CONVERSION TO LIVING SPACE 92 S.F. DRAWING INDEX SHEET NO. DESCRIPTION Al COVER SHEET, GENERAL NOTES A2 ENERGY CODE INFO A3 2ND FLOOR PLAN A4 ELEVATIONS A5 BUILDING CROSS SECTION AND REMODEL DETAIL S1 STRUCTURAL NOTES AND SCHEDULES PROVIDED C CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND FIRESTOPPING SHALL FORM HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND HORIZONTAL) THE ROOF SPACE. FIRESTOPPING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION IN THE FOLLOWING LOCATIONS: 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES NOT TO EXCEED 10'-0" HORIZONTALLY, AND AT THE CEILING AND FLOOR LEVEL. SYMBOL LEGEND 2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, COVE CEILINGS, ETC. CARBON MONOXIDE DETECTOR 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND WALL INTERCONNECTED 110v w/ BATTERY BACKUP CAVITIES IN LINE WITH STRINGERS. C.O. CAN BE COMBINED w/ 5.D. 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS AND FIREPLACES AT CEILING AND FLOOR LEVEL, 5MOKE DETECTOR WITH NON-COMBUSTABLE MATERIALS. O INTERCONNECTED 110v w/ BATTERY BACKUP S.D. 4 EXHAUST FAN (VENT TO OUTSIDE) MISCELLANEOUS 0 KEYNOTE 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. IN THE FIELD PRIOR TO PROCEEDING. 2. VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALL WITH MECHANICAL AND 1t 5TRUGTURAL P05T ELECTRICAL WORK. 3. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH (R314) SMOKE DETECTORS TO BE HARD WIRED AND 101 DOOR 50HEDULE SYMBOL INTERCONNECTED. (R314.4, R314.5). A SMOKE DETECTOR SHALL BE INSTALLED IN EACH SLEEPING ROOM AND OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. (R314) CARBON 11 WINDOW 50HEDULE 5YMB0L MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA AND IN THE VICINITY OF THE BEDROOMS. (R315) Q R-VI51ON- SEE DE5GRIPTION IN 4. KITCHEN RANGE, DRYER, BATH AND LAUNDRY ROOM VENTILATION DUCTS SHALL TERMINATE OUTSIDE THE TITLE BLOCK BUILDING AND BE EQUIPPED WITH BACK DRAFT DAMPERS. 5. EXTERIOR OPENINGS TO THE WEATHER SHALL BE FLASHED AND COUNTER -FLASHED IN SUCH A MANNER AS 51M DETAIL 5YMB0L TO MAKE THEM WATERPROOF. ROOF FLASHING PER R903. 51MILAR DETAIL 6. GUARDRAILS TO BE A MIN. OF 36" ABOVE FINISH FLOOR. (R312) (EXCEPTIONS TO COMMERCIAL PER I.B.C.) A101 DETAIL NO. 7. OPEN GUARDRAILS TO HAVE INTERMEDIATE RAILS OR PICKETS PLACED SUCH THAT A SPHERE 4" IN SHEET NO. DIAMETER CANNOT PASS THROUGH. 8. BEDROOM EMERGENCY EGRESS WINDOWS MUST HAVE A MIN. NET CLEAR OPENING OF 5.7 SQ. FT. MINIMUM elM NET CLEAR OPENABLE WIDTH OF 20" AND MIN. NET CLEAR OPENING HEIGHT OF 24". MAX. FINISHED HEIGHT 1 BUILDING GR055 SECTION OF 44" FROM FINISHED FLOOR TO BOTTOM OF CLEAR OPENING (R310.1). G1 DETAIL NO. SHEET NO. Room name —ROOM NAME ROOM NUMBER (IF e,_-HFDULED) Know what's below. Call before you dig. STATE LAW REQUIRES THAT YOU CALL BEFORE YOU DIG TO LOCATE ALL UNDERGROUND UTILITIES. BANGER RESIDENCE 2ND FLOOR DECK CONVERSION TO LIVING SPACE 711 Main Street, Edmonds WAn 98020 City rjy IIIIIIIIIIIIIIIIIIIIIIIEamom .%A.. Building Department ........................ ..................... Work REMODEL -DECK CONVERSION Address 711 MAIN ST ................................................................................................................................. Owner ` BANGER Approved Date 3/28/2023 Building Official /cclp%� KO � ....................................................., Permit Number: BLD2023-0249 ............................................................................................................ OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED BY PLANNING Mar 24 2023 RECEIVED Feb 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT V z 00 M z QE Q � o U CL Y= WAN LU ��a O "�� J U JL� �co M COS Z cc) W o W m O W n H E O U C d A „ C VI T N ° o c0 °�'=� m m w o 'E.m n Na-oa�F`oo-O sUEnN� ��Q o C=7OJ oo.y o0ocm`°m°1 mL-=E aLU w o o OJH' m ° 0_°0 o-am m0 F Zao y-°'� aEim�oFE�� W V W Q UN z LU Z o N ao Q / o — a w V! Z LU w p w Z o 0 Q LUO O W N W Z z QO V N V W 0 a� is 0 O .N 0 z PROJECT NO. 220403 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL PERMIT SET SHEET NO. Al PRINT DATE 2/22/2023 1:14:45 PM WSEC ALTERATIONS WORKSHEET Alterations Worksheet - 2018 Washington State Energy Code Project Information Contact Information SANGER MASTER BEDROOM DECK CONVERSION TO BEDROOM SPACE. BETH SANGER The WSEC requirements for alterations are located in Chapter 5 of the code text. Alterations (remodels) do not need to obtain energy credits from Table R406.3 Additions must meet the requirements for new construction. This includes nonconditioned space being altered to become conditioned space. Will the wall cavities be exposed? r✓ Yes F_ No If yes: Exposed wall cavities must be insulated - 2 X 4 wall studs require R-15 insulation 2 X 6 wall studs require R-21 insulation Will the roof/ceiling framing cavities or attic be exposed? F,_ Yes F_ No If yes: Exposed roof/ceiling assemblies must be insulated - Vaulted ceilings: Insulate to the full depth of the framing member while allowing for the minimum 1" ventilated space Flat ceilings Will the floor framing cavities be exposed? 2018 WASHINGTON STATE ENERGY CODE FENENSTRATION CALCULATIONS NEW VERTICAL GLAZING 90 SF LESS EXEMPT GLAZING -00 SF GLAZED DOORS PLUS OTHER EXTERIOR DOORS 00 SF TOTAL FENESTRATION: 90 SF NOTE: SEE SHEET A5 FOR ADDITIONAL INSULATION LOCATIONS AND DETAILS, ENERGY CREDITS Install R-49 insulation or what the attic space can accommodate based on the roof pitch OPTIONS DESCRIPTION F,_ Yes F_ No If yes: Exposed floor cavities must be insulated to R-30 Are the windows and/or doors being replaced? W Yes F_ No (includes both window or door and frames) If yes: New windows and doors must have an area weighted average U-factor of :50.30 Will the heating or cooling system be replaced? F_ Yes F,_ No If yes: New equipment must meet current requirements and ducts need to be tested Will the hot water system be altered? F_ Yes R_ No If yes: New water heating equipment must meet current code requirements Are more than 50% of the light fixtures being changed? F_ Yes R_ No If yes: 75% of all lamps must be high efficacy (LED or CFL) R503.1.1 Building envelope. Building envelope assemblies that are part of the alteration shall comply with Section R402.1.1 or R402.1.4, Sections R402.2.1 through R402.2.11, R402.3.1, R402.3.2, R402.4.3 and R402.4.4. Exception: The following alterations need not comply with the requirements for new construction provided the energy use of the building is not increased: 1. Storm windows installed over existing fenestration. 2. Existing ceiling, wall or floor cavities exposed during construction provided that these cavities are filled with insulation. 2x4 framed walls shall be insulated to a minimum of R-15 and 2x6 framed walls shall be insulated to a minimum of R-21. 3. Construction where the existing roof, wall or floor cavity is not exposed. 4. Roof recover. 5. Roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing shall be insulated either above or below the sheathing. 6. Surface -applied window film installed on existing single pane fenestration assemblies to reduce solar heat gain provided the code does not require the glazing fenestration to be replaced. R503.1.1.1 Replacement fenestration. Where some or all of an existing fenestration unit is replaced with a new fenestration product, including sash and glazing, the replacement fenestration unit shall meet the applicable requirements for U-factor and SHGC in Table R402.1.1. Where more than one replacement fenestration unit is being installed, an area -weighted average of the U-factor and SHGC of all replacement fenestration shall be permitted to be used to demonstrate compliance. R503.1.2 Heating and cooling systems. New heating, cooling and duct systems that are part of the alteration shall comply with Section R403. Exceptions: 1. Where ducts from an existing heating and cooling system are extended, duct systems with less than 40 linear feet in unconditioned spaces shall not be required to be tested in accordance with Section R403.2.2. 2. Existing duct systems constructed, insulated or sealed with asbestos. R502.1.1.2 Heating and cooling systems. New heating, cooling and duct systems that are part of the addition shall comply with Section R403. Exception: The following need not comply with the testing requirements of Section R403.3.3: 1. Additions of less than 750 square feet. 2. Duct systems that are documented to have been previously sealed as confirmed through field verification and diagnostic testing in accordance with procedures in WSU RS-33. 3. Ducts with less than 40 linear feet in unconditioned spaces. 4. Existing duct systems constructed, insulated or sealed with asbestos. R503.1.3 Service hot water systems. New service hot water systems that are part of the alteration shall comply with Section R403.5. R503.1.4 Lighting. New lighting systems that are part of the alteration shall comply with Section R404.1. Exception: Alterations that replace less than 50 percent of the luminaires in a space, provided that such alterations do not increase the installed interior lighting power. R503.2 Change in space conditioning. Any nonconditioned or low -energy space that is altered to become conditioned space shall be required to be brought into full compliance with this code. HEATING Combustion heating equipment meeting minimum federal OPTION 1 efficiency standards for the equipment listed in Table C403.3.2(4) or C403.3.2(5) (EXISTING UNIT) ENERGY Energy Star rated (U.S. North) Gas or propane furnace with OPTION 3.1 minimum AFUE of 95% (EXISTING UNIT MEETS THIS REQUIREMENT.) ENERGY Water heating system shall include one of the following: OPTION 5.2 Energy Star rated gas or propane water heater with a minimum UEF of 0.80. (EXISTING UNIT MEETS THIS REQUIREMENT.) TOTAL CREDITS CREDIT 1.0 0.5 1.5 R301 CLIMATE ZONE THIS PLAN IS DESIGNED FOR CLIMATE ZONE 5 AND MARINE 4 PER TABLE R301.1, 2018 WASHINGTON STATE ENGERY CODE. R402.2 FENESTRATION (PRESCRIPTIVE) R402.3 Fenestration (Prescriptive). In addition to the requirements of Section R402, fenestration shall comply with Sections R402.3.1 through R402.3.6. R402.3.1 U-factor. An area -weighted average of fenestration products shall be permitted to satisfy the U-factor requirements. R402.3.2 Glazed fenestration SHGC. An area -weighted average of fenestration products more than 50 percent glazed shall be permitted to satisfy the SHGC requirements. R402.3.3 Glazed fenestration exemption. Up to 15 square feet (1.4 m2) of glazed fenestration per dwelling unit shall be permitted to be exempt from U-factor and SHGC requirements in Section R402.1.1. This exemption shall not apply to the U- factor alternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4. R402.3.4 Opaque door exemption. One side -hinged opaque door assembly up to 24 square feet (2.22 m2) in area is exempted from the U-factor requirement in Section R402.1.1. This exemption shall not apply to the U-factor alternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4 R404.1 LIGHTING EFFICACY N/A NO CHANGE TO EXISTING VENTILATION SYSTEM1 IVI II V. VI .7V /e VI L/'91VIr ..1 IIV r LI\I VIrl1VLIV I L I IIVJ I/"�LL MD FIXTURES SHALL BE HIGH EFFICACY LAMPS. M 1505 MECHANICAL VENTILATION PRESCRIPTIVE ENERGY CODE COMPLIANCE 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Version 1.0 These requirements apply to all IRC building types, including detached one- and two-family dwellings and multiple single-family dwellings (townhouses). Project Information Contact Information BANGER DECK CONVERSION TO LIVING SPACE BETH SANGER Instructions: This single-family project will use the requirements of the Prescriptive Path below and incorporate the minimum values listed. Based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Provide all information from the following tables as building permit drawings: Table R402.1- Insulation and Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 406.3 - Energy Credits. Authorized Representative Date 02/22/2023 All Climate Zones (Table R402.1.1) R-Value a U-Factor a Fenestration U-Factor b n/a 0.30 Skylight U-Factor b n/a 0.50 Glazed Fenestration SHGC b,e n/a n/a Ceiling a 49 0.026 Wood Frame Wall g.h 21 int 0.056 Floor 30 0.029 Below Grade Wall `•h 10/15/21 int + TB 0.042 Slab d,f R-Value & Depth 10, 2 ft n/a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity that is less a than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. "10/15/21 +5TB11 means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at c the interior of the basement wall. "10/15/21 +5TB11 shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. 115TB" means R-5 thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1. For single rafter- orjoist-vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth e extends over the top plate of the exterior wall. R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall meet the requirements for thermal barriers protecting foam plastics. For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for g climate zone 5 of ICC 400. Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard h framing 16 inches on center, 78% of the wall cavity insulated and headers insulated with a minimum of R-10 insulation. Prescriptive Path - Single Family 2018 Washington State Energy Code-R 1 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington HEATING SYSTEM SIZE simple heating System size: wasnington state This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Single Family - New & Additions (effective February 1, 2021) Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of credits. To claim this credit, the building permit drawings shall specify the option selected and the maximum tested building air leakage, and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit: 3 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit: 6 credits All dwelling units that are not included in #1 or #3 3. Large Dwelling Unit: 7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 1.5 credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4. Summary of Table R406.2 Heating O tions Fuel Normalization Descriptions p Credits - select ONE heating option User Notes 1 Combustion heating minimum NAECAb 0.0 ❑ EXISTING 2 Heat pump` 1.0 ❑ 3 Electric resistance heat only - furnace or zonal -1.0 ❑ 4 DHP with zonal electric resistance per option 3.4 0.5 ❑ 5 All other heating systems -1.0 ❑ Energy Credits - select ONE Options Energy Credit Option Descriptions energy option from each category 1.1 00? z®1717 0.5 ❑ 1.2 Efficient Building Envelope 1.0 ❑ 1.3 Efficient Building Envelope 0.5 ❑ 1.4 Efficient Building Envelope 1.0 ❑ 1.5 Efficient Building Envelope 2.0 ❑ 1.6 Efficient Building Envelope 3.0 ❑ 1.7 Efficient Building Envelope 110.5 ❑ 2.1 Air Leakage Control and Efficient Ventilation 0.5 ❑ 2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑ 2.3 Air Leakage Control and Efficient Ventilation 1.5 ❑ 2.4 Air Leakage Control and Efficient Ventilation Li 2.0 ❑ 3.1a High Efficiency HVAC 1.0 0 EXISTING H.E. UNIT 3.2 High Efficiency HVAC 1.0 ❑ 3.3a High Efficiency HVAC 1.5 ❑ 3.4 High Efficiency HVAC 1.5 ❑ 3.5 High Efficiency HVAC 1.5 ❑ 3.6a High Efficiency HVAC U 2.0 ❑ 4.1 High Efficiency HVAC Distribution System 0.5 ❑ 4.2 High Efficiency HVAC Distribution System 1.0 ❑ Prescriptive Path - Single Family 2018 Washington State Energy Code-R 2 Project Information Contact Information BANGER DECK CONVERSION TO BEDROOM BETH SANGER Heating System Type: O All other systems O Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions" Design Temperature Instructions I Design Temperature Difference (AT) 46 Edmonds I AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 92 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.1 745 Glazing and Doors U-Factor X Area = UA Instructions u-0.30 J 0.300 90 27.00 Skylights U-Factor X Area = UA Instructions 0.50 0� --- Insulation Attic U-Factor X Area = UA Instructions R 49 I 0.026 92 1I 2.39 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No Vaulted Ceilings in this project. J Above Grade Walls (see Figure t) U-Factor X Area UA Instructions R-21 Intermediate 0.056 153 8.57 Floors U-Factor X Area UA Instructions 0.029 92 J 2.67 R•30 � Below Grade Walls (see Figure 1) U-Factor X Area UA _ Instructions No Below Grade Walls in this project 0.028 0� Slab Below Grade (see Figure 1) F-Factor X Length UA Instructions 0.303 --- No Slab Below Grade in this project � Slab on Grade (see Figure 1) F-Factor X Length UA Instructions No Slab on Grade in this project Location of Ducts Instructions - Duct Leakage Coefficient Conditioned Space 1.00 Sum of UA 40.63 Envelope Heat Load 1,869 Btu / Hour Figure 1. Sum of UA x AT Air Leakage Heat Load 370 Btu / Hour Volume x 0.6 x AT x 0.018 Above Grade Building Design Heat Load 2,239 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 2,239 Btu / Hour Ducts in unconditioned sDace: sum of buildina heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 2,799 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Buildina and duct heat loss x 1.25 for heat pump (07101113) 2018 Washington State Energy Code - Residential 9 gY Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Summary of Table R406.2 (cont.) Energy Credits - select ONE Energy Credit Option Descriptions (cont.) energy option from User Notes Options each category d 5.1d Efficient Water Heating 0.5 ❑ 5.2 Efficient Water Heating 0.5 El 1EXISTING HIGH EFFEC. UNIT 5.3 Efficient Water Heating 1.0 ❑ 5.4 Efficient Water Heating 1.5 ❑ 5.5 Efficient Water Heating 2.0 ❑ 5.6 Efficient Water Heating 2.5 ❑ 6. le Renewable Electric Energy (3 credits max) 1.0 Q 7.1 Appliance Package 0.5 ❑ Total Credits lCalculate Total Clear Form a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. b. Equipment listed in Table C403.3.2(4) or C403.3.2(5) c. Equipment listed in Table C403.3.2(1) or C403.3.2(2) d. You cannot select more than one option from any category EXCEPT in category S. Option 5.1 may be combined with options 5.2 through 5.6. See Table 406.3. e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max. See the complete Table R406.2 for all requirements and option descriptions. f. Use the single radiobutton in the upper right of the second column to deselect radiobuttons in that group. Please print only pages 1 through 3 of this worksheet for submission to your building official. Prescriptive Path - Single Family 2018 Washington State Energy Code-R RECEIVED Feb 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 3 U Z N co 00 0) Z Q E Q � o CL W W � ur) � J JL� U ��o M Z coN` LU @ lad OX m W m o W n H E O U r_ � br �IVf U C N �Nq 16 y 3 J y L (6 T Q( 2 2 5 p Z Cp C r ` N 0_ J .02 co) N F Na oalFoo� oE c i>Y 4 Famo�mat c ay O J y. O C@ O t6 O O O O D 2 N L N` U 0'o d o- 2 c y or.- m ..0 E vl E. 0 U O UCCNNN Lu Omoom o N Q O N E Ul N N O F c W V Wa VN Z W Z O nl 0o a Q > O � a w h z W w 0 w Z o 0 O Q W 0 N � W H W z a0 U he W 0 to 0 s= 0 T) a� IY 0 Z PROJECT NO. 220403 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL PERMIT SET SHEET NO. A2 PRINT DATE 2/22/2023 1:15:03 PM WINDOW SCHEDULE - NEW WINDOWS SYM. NO. WIDTH HEIGHT AREA TYPE U-VALUE Comments 2ND FLOOR W3 8' - 0" 6' - 0" 48 SF WINDOW - FIXED TEMP. GLASS W4 3' - 6" 6' - 0" 21 SF CASEMENT - SINGLE TEMP. GLASS W5 3' - 6" 6- 0" 21 SF CASEMENT - SINGLE TEMP. GLASS Grand total 90 SF W3 - SOANDERSEN-APW8060, Unit, A 1 EA, Series Picture Window, Standard, Product Performance, 4 9/16", Frame Depth, Standard Flange„ Black Exterior Frame, Black, Exterior Sash/Panel, Pine, w/Primed Interior Frame, Fixed„ Dual Pane Low-E4 SmartSun, Tempered Argon Fill Stainless, Glass / Grille Spacer. W4 & W5 SOANDERSEN-ACW3660, Unit, A 1 EA Series Casement, Standard, Product Performance, 4 9/16", Frame Depth, Standard Flange„ Black Exterior Frame, Black, Exterior Sash/Panel, Pine, w/Primed Interior Frame, Pine, w/Primed Interior Sash/Panel„ Right, Dual Pane Low-E4, SmartSun, Tempered Argon Fill Stainless, Glass / Grille Spacer„ Contemporary Folding, Oil Rubbed, Bronze, White, Full Screen„ Aluminum - EXISTING GABLE WALL, POST AND O BEAMS - NO CHANGE EXISTING ROOF STRUCTURE - NO CHANGE O O NEW TRIM TO -------- MATCH EXISTING T _____________ --------------- NEW WINDOWS PER ------ ------------------ ------ SCHEDULE ---------------------- ------------------ - IIII- ------------ �idl�,�:',;�� IIII IIC� � _--- ll O --- ---- -- ni - -- NEW EGRESS WINDOW -=- BOTTOM OF CLEAR OPENING BLUE LINES INDICATE EXISTING ---IS NOT TO EXCEED 44" ABOVE FLOOR. GUARDRAILS TO BE REMOVED. -- OPENABLE AREA IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS - EXISTING WALLS, — ----- ALLOWED FOR AN OPENING WITHIN TRIM AND SIDING TO REMAIN. 0-----44" OF FINISHED GRADE. (R310.1) WINDOWS TO ENCLOSE ----------- EXISTING OPENINGS. - ----------------- 3 , AREA OF REMODEL E F — — — — — — — i \ I — 80CFM Master Bath O V.T.O. V 3 A4 M-4 G NEW FIXED WINDOW LIN OF WALL PER SCHEDULE - - -f - BELOW �\ O REMOVE EXISITNG GUARDRAIL AND INFILL WALL OPENING '1Z) / �`\ I LU I FOR NEW WINDOW. EXISTING HEADER ABOVE TO \ 5 \ REMAIN IN PLACE. NEW SINGLE HUNG WINDOW / TO MATCH EXISTING WINDOWS DEMO EXISTING WALL, ` NEW ADDI ION DOORS, WINDOWS AND `\ TRIM. CID 3 A4 � Pri ary I suite \ \ REMOVE EXISTING W/ INFILL EXISTING MEMBRANE AND RE-F OPENING AS NEEDED LEVEL OF MAIN FLOO[ FOR NEW WINDOW SIZE. �� FILLER OR PLYWOOD NEW EGRESS WINDOW IN `\ 2 EXISTING OPENING - — — — \\ — I O O O S.D. S.D. I �I 1 I L I I I Bedroc "" WALL LEGEND NEW WALLS EXISTING WALLS TO REMAIN — — — — — — WALLS AND STRUCTURES TO BE REMOVED i G I I I I I I II I I I � I Bedroom #2 —� 80 CFM Bath Vi I O L O W D� 120 CFM Laundry W„o�USE I FURN. DIN 00 I C.O.I S.D. Ll St it Hall Elevator � - — r 2ND FLOOR PLAN 1/4" = 1'-0" RECEIVED Feb 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT V Z — N W O W Z a E a �8 CL Y= m 0 J �, CM CD �O Z OR W o W to 0 W IL W V W Q UN Z W Z O N ao Q > O — a w V! Z LU w 0 w Z oE 0 Q W 0 0 W N W Z Z Q 0 V N V W 0 cc 0 c 0 M a) 0 z PROJECT NO. 220403 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL PERMIT SET SHEET NO. A3 PRINT DATE 2/22/2023 1:15:18 PM AREA OF REMODEL Max. Height 187.02 2ND FLR PLATE 2ND FL 181.08 181.08 2ND FLOOR / 2ND FL 172.99 172.99 Top Plate 171.59 MAIN FLOOR _____ _162.50_ AVE. GRADE III III @162.0)' III III III III III III III III III IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII I� III III III III III III IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII1111111111111111111111 �Q 00 I' III III -III III III III III III III III III III III III III III III III III III III III III III III III III III III, III- III III, I I I I I III III III I- III III III I I 1 111 I I I I I I I.III —III III III III I I;:. III III- BASEMENT FLOOR 152.50 III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III I I II I II I II I �I I I� � �I III III III III II III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III= III III III "' _III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III WEST ELEVATION 1/4" = 1'-0" WALL LEGEND NEW WALLS EXISTING WALLS TO REMAIN — — — — — — WALLS AND STRUCTURES TO BE RFMOVFD WALL 3 l 11 _ / 1 /4 - 1-011 NEW FIXED WINDOW PER SCHEDULE AND SPECS. INFILL WALL AS NEEDED AROUND NEW WINDOW. ELEVATION AREA OF REMODEL Max. Height 187.02 ti (V rp \ I 04 00 ' NOR Im EL ll MEN SEEN HIRE INNER HOME HIRE 1111 2ND FLR PLATE 181.08 NORTH ELEVATION 1 /4" = 1'-0" 2ND FLOOR 172.99 Top Plate 171.59 MAIN FLOOR 162.50 FLOOR 152.50 RECEIVED Feb 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT V z N W O W z E Q >a > U CL m Y= Lu o 4n w � a) 0 J�43) �m@ co (6 z co 04 W �! .ru Oa) W to 0 W n H E O U C C „ Bit O y d p Op O�- y N O 2 l0 t, y 2 U LL -O ^' U T L O N w C .._�. N l0 U E No 6 a W O a E N N y O n d C N 0 U Ow Uo co o o c cmm U J J O N C C O U a H l0 U Vi O.{p � O Za�'�@ aEid�o�E@� W Lu UN z� Lu Z o N ao o� Q / o � a � w N Z LJJ 1— Lu p L u o E 0 Q W O 0 N _ W N W Z Z Q 0 V N V W 0 cc 0 c 0 M a) z PROJECT NO. 220403 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL PERMIT SET SHEET NO. A4 PRINT DATE 2/22/2023 1:15:36 PM MAX. H E K 187.021 2ND FLR 181.081 �` 2ND FLO( 172.99, 07170-1p5_7A] (--` MAIN FLC 162.5' 0BASEMEP 152.50' I Q, 03 11 7 C1, 1 11 n A' 1 1 1i n Ui _�Cl� I IUN ANU NtVV UC I AILS 1/2"=11-OVI RECEIVED Feb 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT V z — N W O W z >a E Q > U CL m Y= Lu a 4n W ,n N O C) 2m@ co (6 z coN` W �! .ru W to O W n H E C O O '', C O � Z Nam C.0 :: OL F O p T j L U E U y C 2�¢na�aw Ccm�..o��o J 00JOydp�p� O� m-y2 U LL O N w C .. L`pI l0 U S E yp a W O a E d y W O n w d o +y. C y 0 U O W 7i V o c U o o c c_ 3& m y UJJHa0Lu mO m� o Za�'�@ E.— d W V W Q UN Z LU Z o N co Q > o a � a � w N z LU w p LU o E 0 Q W O 0 t/1 � W N W > Z Z Q 0 V N V W 0 cc 0 a M a) 0 Z PROJECT NO. 220403 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL PERMIT SET SHEET NO. A5 PRINT DATE 2/22/2023 1:15:49 PM GENERAL NOTES All design and construction shall conform to the requirements of the 2018 International Building Code. Contractor shall verify all levels, dimensions and existing conditions in field before proceeding with any construction or demolition. Contractor shall notify the Architect of any discrepancies or field changes Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the work. Contractor shall provide adequate shoring and bracing of all structural members, existing construction and soil excavations as required, in a manner suitable to the work sequence. Temporary shoring and bracing shall not be removed until all final connections have been completed in accordance with the drawings and materials have achieved design strength. Foundations walls greater than 4 feet shall not be backfilled until the floor framing and all connections to the floor framing per these details are complete. CHANGES: No changes to these structural drawings are permitted without written consent of the Engineer. Changes will be billed to the client, owner or contractor at the Engineer's hourly rate. SUBMITTALS: Shop drawings shall be submitted to the Architect prior to any fabrication or construction for all the following: Structural steel, steel canopies, glued -laminated members and pre -manufactured wood members. Design drawings and calculations, for pre -manufactured wood trusses and joists shall bear the seal and signature of the Washington State Registered Professional Engineer who is responsible for the design, and shall be submitted to the Architect and Building official for review prior to fabrication. WOOD SAWN LUMBER: Structural sawn lumber shall be kiln dried and be of the species and grade noted below or better: Use Grade Fb(psi) Wall Studs Hem Fir Stud 675 Plates & Planks Hem Fir #2 850 Joists & Rafters Hem Fir #2 850 4x Beams Douglas Fir -Larch #2 900 6x Beams Douglas Fir -Larch #2 875 Posts Douglas Fir -Larch #2 750 2x4 T&G Decking Douglas Fir -Larch Select 1750 All lumber and plywood exposed to weather or water or in contact with concrete, stucco, masonry or other cementitious materials shall be treated with an E.P.A. acceptable wood preservative, such as Alkaline -Copper -Quaternary "ACQ" or Copper Azole "CBA" type A and B. All wood connectors shall be manufactured by Simpson Strong Tie Company (or approved equal), and of the size and type shown on the drawings. All wood connectors in contact with preservative -treated wood shall be Triple Zinc G-185 galvanized (1.85 oz/sq ft coating). MINIMUM WOOD NAILING REQUIREMENTS: Unless otherwise noted on the drawings, typical wood framing shall be fastened as follows. See IBC Table 2304.10.1 for fastener alternatives not shown. Location Min. Nail Quantity/Spacing Type* Beams (built up 2x's) 3" x 0.131" 24" o.c. T&B* FN EF* staggered Blocking -to joists, rafters, trusses 3" x 0.131" 2 each end TN or studs -to top plates 3" x 0.131" 3 TN Bottom plate -to joist, rim joist 3" x 0.131" 12" o.c. FN or blocking -to studs 3" x 0.131" 3 EN Header (built up 2x's) 16d box 12" o.c. T&B FN Header -to studs 3" x 0.131" 4 TN Joist -to supports 3" x 0.131" 3 TN -to rim joist 3" x 0.131" 4 EN Rafter -to supports 3" x 0.131" 4 TN, EN Rim Joist -to sill or blocking 3" x 0.131" 6" o.c. TN Stud -to Stud 3" x 0.131" 12" o.c. FN -to top/bottom plate 3" x 0.131" 4 TN Top plate -to top plate 3" x 0.131" 12" o.c. FN -to studs 3" x 0.131" 3 EN -laps at corners and 3" x 0.131" 3 FN intersections Truss to top plate 3" x 0.131" 4 TN *EN = end nail, FN = face nail, TN = toe nail, EF = "each face", T&B = "top and bottom" RATED SHEATHING: Wood structural panels shall bear the APA trademark of the American Plywood Association. Sheathing shall be as follows: Shear Wall Shtg APA rated 7/16" 32/16 C-D INT with Exterior Glue (CDX or OSB) Roof Shtg APA rated 15/32" 32/16 C-D INT with Exterior Glue (CDX or OSB) Sub Floor Shtg APA rated 3/4" 48/24 T&G C-D INT with Exterior Glue Sheathing shall be orientated over the supports as shown on the drawings. Shear wall sheathing shall be blocked at all panel edges as shown in the shear wall schedule. GLUED LAMINATED MEMBERS: Glued Laminated members shall each bear an AITC identification mark and be accompanied by an AITC certificate of conformance. One coat of end sealer shall be applied immediately after trimming either shop or field. Members shall be Visual Graded Western Species Inductrual, Architectural or Premium grade with strength as follows: Plan Symbol Common Name Species Fb E GLULAM Glulam DF 24F-V4 DF/DF 2400/1850 psi 1,800,000 psi GLULAM V8 Glulam DF 24F-V8 DF/DF 2400/2400 psi 1,800,000 psi RECEIVED Feb 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT STRUCTURAL NOTES Ross Engineering Design Inc JOB # 16013 ryan.ross@rossengineer.com 6.27.2022 yPN N. 1yo pF WASH/,y 16 B13 46411 'QFGISTVE SS�ON A. ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN (D U rM o N O CID C O LU . W 06 N N W a� (� 00 0 0 �L N O Z FILE/ NO. DATE DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: S1 PRINT DATE 5 / 9 / 2022