APPROVED BLD BLD2023-1443+Architectural_Plan+11.10.2023_4.03.11_PM+3894719Robertson Residence PVE Elevator
PROJECT INFORMATION
PROJECT OWNER AND ADDRESS:
DONALD AND SUZANNE ROBERTSON
745 FIR STREET
EDMONDS, WA P8020
CONTACT: DONALD ROBERTSON
PHONE: (206) 713-0635
EMAIL: ROBER7SON35@COMCAS7.NE7
LEGAL DESCRIPTION:
YOSTS 157 ADD TO EDMONDS PLAT OF BLK 003 D-01 - LOT 2 OF
CITY OF ED SP-S-5-BP REC AF NO SP08140242 BEINGA PTN OF SE
1/4 NW 1/4
ASSESSOR PARCEL NUMBER: 00(cl P400300501
PROJECT NUMBER: XXX
OCCUPANCY GROUP: R-3
CONSTRUCTION TYPE: V-S (NON SPRINKLED)
LOT COVERAGE:
LOT AREA: 7, 500 (.17 ACRES)
EXISTING BUILDING: 2,528 SF
ADDITION: 0 SF
TOTAL COVERAGE: 2, 52B SF (33.71%)
ZONING: RS-6
PERMITTING AGENCIES:
CITY OF EDMONDS PLANNING AND DEVELOPMENT
121 57H AVE NORTH
EDMONDS/ WA PBO20
P: (425) 771-0220
SNOHOMISH COUNTY PLANNING AND DEVELOPMENT
3000 ROCKEFELLER AVENUE, M/S 604
SECOND FLOOR, ROBERT DREWEL BUILDING
EVERETT/ WA P8201
APPLICABLE CODES AND REGULATIONS:
2022 SNOHOMISH COUNTY CODE (SCC)
201E INTERNATIONAL RESIDENTIAL CODE (IRC)
201E WASHINGTON STATE ENERGY CODE (WSEC)
s
n
SITE PLAN
SCALE: 1" = 10'-0"
DATE
REV1
REV2
REV3
REV4
ocvrl
SHEET INDEX
A1.0
A2.0
A3.0
PROJECT VICINITY
GENERAL PROJECT NOTES
SITE PLAN, GENERAL INFORMATION, PLAN NOTES I I l 1.
AS BUILT / DEMOLITION PLANS VERIFY DRAWINGS BY DIMENSION ONLY SCALE IS FOR
�'
ENLARGED PLANS, FRAMING PLAN AND SECTION VISUAL REFERENCE ONLY.
2. ALL DIMENSIONS ARE TO FACE OF EXISTING CONCRETE
WALLS AND TO CENTERLINE OF COLUMNS AND NEW
PROJECT SUMMARY: Edmonds
=a - INTERIOR PARTITION WALLS UNLESS OTHERWISE NOTED.
CONSTRUCTION OF RESIDENTIAL INTERIOR TWO STOP FIVE ��
�" `._; - ■ = B. CONTRACTOR TO IDENTIFY MAINTAIN AND PROTECT
(PNEUMATIC) ELEVATOR AT SOUTHWEST CORNER OF A :
`
RESIDENCE. EXIS71NG UNDERGROUND SYSTEMS DURING EXCAVATION AND
4 INSTALLATION OF NEW UTILITIES.
-
PROJECT _ �}
LOCATION *sothell 4. PROVIDE REPETITIVE FEATURES NOT FULLY SHOWN OR
1 -I �.•Jr - NOTED IN DRAWINGS AS IF FULLY SHOWN.
City Of Edmonds r
Building Department
Work ELEVATOR
-------------------------------------------------------------------------
--------------------------
Address 745 FIR ST
---------------------------------------------------------------------
-----------------------------------------------------------------------
Owner ROBERTSON
--------------------------------------------------------
Approved Date: 12/04/2023
--------------------------------------
Building Official:'__ w. W
Permit Number
BLD2023-1443
---------------------------------
REVISIONS
- PAGES -
CHANGES
- 5. PLANS WHICH APPEAR AS BACKGROUNDS ON CIVIL,
STRUCTURAL, PLUMBING, HVAC, AND ELECTRICAL DRAWINGS
ARE FOR THE PURPOSE ONLY OF ILLUSTRATING GENERAL
PLAN CONFIGURATION. REFER TO THE APPROPRIATE
DISCIPLINE FOR EACH SPECIFIC PORTION OF WORK.
Yf 7
6. PLACE NO MAINS, PIPING, CONDUIT, OR OBSTRUCTIONS
OF ANY KIND SO AS TO IMPAIR GIVEN CEILING HEIGHTS AND
- ARCHITECTURAL CLEARANCES.
7. PROVIDE 2X SOLID BLOCKING FOR ALL JOISTS,
RAFTERS, AND TRUSSES AT BEARING POINTS TO PREVENT
ROTATION OR LATERAL DISPLACEMENT.
SEATTLE ° y. B. CONSTRUCTION TO BE STABILIZED AGAINST LATERAL
MOVEMENT IN ACCORDANCE WITH THE REQUIREMENTS OF
THE LATEST ADOPTED EDITION OF THE INTERNATIONAL AND
NOTE: MECHANICAL, ELECTRICAL AND PLUMBING TO BE CITY BUILDING CODES.
DEFERRED SUBMITTALS UNDER SEPARATE PERMIT. q. ELECTRICAL AND MECHANICAL ARE DESIGN BUILD BY
■.■.■.■.■,■.■.■,■.■.■,■.■.■,■.■.■.■.■.■.■.■,■.■, OTHERS. ELECTRICAL AND MECHANICAL PERMITTING
' The following documentation shall be available on - OBTAIN ELEVATOR OBTAIN ELECTRICAL DOCUMENTS TO BE SUBMITTED BY CONTRACTOR AND ARE
site for the building inspector: PERMIT FROM PERMIT FROM REQUIRED TO COMPLY WITH ALL CODES AND REGULATIONS
■ STATE LABOR& STATE LABOR& OF THE JURISDICTION HAVING AUTHORITY.
INDUSTRIES INDUSTRIES
■
'. ❑X COE APPROVED ARCHITECTURAL PLAN SET '. 10. PROVIDE SAFETY IN THE AREA OF WORK IN ACCORDANCE
■ ■ TO APPLICABLE SAFETY CODES.
❑ COE APPROVED STRUCTURAL PLAN SET ; OBTAIN ELECTRICAL
■ PERMIT FROM 11. NDEMNIFY AND HOLD THE OWNER/ARCHITECT HARMLESS
[]COE REVIEWED CALCULATION PACKET STATE LABOR & FOR INJURY OR DEATH TO PERSONS OR FOR DAMAGE TO
■ ■ INDUSTRIES
. ❑ENERGY CREDIT WORKSHEET ; PROPERTY CAUSED BY THE NEGLIGENCE OF THE
❑ SITE PLAN CONTRACTOR, CONTRACTOR'S AGENTS, EMPLOYEES OR
■ ■ SUBCONTRACTORS.
■ ❑ CIVIL PLAN APPROVED
■ ❑ Manufacture Spec. Plans '. PLANS MUST BE 12. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO
■ ON JOB SITE ADJACENT WORK AND IS TO REPAIR SAID DAMAGE AT
❑ ■ CONTRACTOR'S EXPENSE.
13. CODES: WORK IS TO CONFORM TO THE APPLICABLE
BUILDING CODES AND ORDINANCES. IN CASE OF ANY
CONFLICT WHERE THE METHODS OR STANDARDS OF
INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL
OR EXCEED THE REQUIREMENTS OF THE LAWS OR
ORDINANCES, THE LAWS OR ORDINANCES SHALL GOVERN.
NOTIFY ARCHITECT OF CONFLICTS.
14. INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO
EXISTING CONDITIONS ARE BASED ON BEST PRESENT
KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. FIELD
VERIFY EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY
THE ARCHITECT OF DISCREPANCIES OR CONDITIONS
}— ADVERSELY AFFECTING THE DESIGN PRIOR TO PROCEEDING
WITH THE WORK.
OI 15. EXISTING UTILITY LINES WILL BE USED AND NO WORK
WILL OCCUR IN THE TREE PROTECTION AREA. IF NEW
LLl UTILITY WORK MUST OCCUR WITHIN THE TREE PROTECTION
AREA, NO TRENCHING SHALL OCCUR WHICH MAY HARM
z EXISTING TREES.
W
} I FIRE PROTECTION NOTES:
1. NO STORAGE OR USE OF FLAMMABLE OR COMBUSTIBLE
7T LIQUIDS, TORCH CUTTING OR WELDING OPERATIONS, OPEN
FLAME WORK, GRINDING THAT PRODUCES SPARKS, ROOFING
120 OPERATIONS, OR USE OF FLAMMABLE GAS FOR TEMPORARY
HEATING OR DRYING SHALL BE CONDUCTED ON ANY
CONSTRUCTION SITE WITHOUT FIRST HAVING OBTAINED A
SPECIFIC PERMIT FROM THE SHORELINE FIRE DEPARTMENT
FOR THESE HAZARDOUS ACTIVITIES. THIS INCLUDES
DEMOLITION WORK,
2. EGRESS, FIRE PROTECTION SYSTEMS, AND EMERGENCY
ACCESS SHALL MEET THE REQUIREMENTS OF THE
RESIDENTIAL FIRE CODE CHAPTER 14 DURING CONSTRUCTION.
CONTRACTOR MATERIALS AND ACTIVITIES SHALL NOT BLOCK
ANY EXIT, RESTRICT EMERGENCY ACCESS, OR IMPAIR FIRE
SEPARATION IN ANY BUILDING WHILE THE BUILDING IS
OCCUPIED. THIS INCLUDES DEMOLITION WORK AND ALSO
APPLES TO NEIGHBORING SPACES, AREAS, AND BUILDINGS.
S. A SMOKE DETECTOR SHALL BE INSTALLED IN EACH
HABITABLE ROOM AND AT THE BOTTOM OF ALL STAIRS.
ALL SMOKE DETECTORS SHALL BE 110V WITH BATTERY
Rdl-.KI1P
FIR STREET
FRAMING NOTES
1. MINIMUM LIVE LOAD 50 LBS / SF. CONCRETE COMPRESSIVE
DESIGN STRENGTH B500 PSI.
2. ALL HARDWARE (BOLTS, NUTS AND WASHERS, JOIST
HANGERS, MECHANICAL FASTENERS, HOLDOWNS, TIE PLATES
CAST -IN -PLACE POST ANCHORS, ETC.) SHALL BE
GALVANIZED ZINC COATING OR STAINLESS STEEL. HARDWARE
PRODUCTS FROM SIMPSON STRONG -TIE OR OR EQUAL,
INSTALL PER MANUFACTURERS RECOMENDATIONS.
S. ALL JOISTS, COLUMNS, STUDS AND BEAMS SHALL BE
PRESSURE TREATED DOUGLAS FIR -LARCH #2 OR BETTER
MEMBERS UNLESS NOTED OTHERWISE. EXPOSED MEMBER
SHALL BE NON -INCISED.
ABBREVIATIONS
AFF
FINISH FLOOR
N
NORTH
APPROX
APPROXIMATE
NIC
NOT IN CONTRACT
ARCH
ARCHITECTURAL)
NO
NUMBER
BLDG
BUILDING
NTS
NOT TO SCALE
BM
SEAM
CA
OVERALL
CL
CENTER LINE
OC
ON CENTER
CLG
CEILING
OD
OUTSIDE DIAMETER
CMU
CONCRETE MASONRY UNIT
OPP
OPPOSITE
GONG
CONCRETE
PLWD
PLYWOOD
CONT
CONTINUE/CONTINUOUS
PR
PAIR
DEMO
DEMOLITION/DEMOLISH
PT
PAINT, PRESSURE TREATED
DIA
DIAMETER
PTN
PARTITION
DIM
DIMENSION
R
RADIUS, RISER
DN
DOWN
RCP
REFLECTED CEILING PLAN
DS
DOWNSPOUT
REF
REFERENCE, REFRIGERATOR
DWG
DRAWING
REINF
REINFORCED
E
EAST
RM
ROOM
(E)
EXISTING
R N G
RANGE
EA
EACH
S
SOUTH
ELEC
ELECTRICAL)
SCHED
SCHEDULE(D)
ELEV
ELEVATION
SECT
SECTION
EXT
EXTERIOR
SHT
SHEET
FA
FIRE ALARM
SIM
SIMILAR
FD
FLOOR DRAIN
SQ
SQUARE
FE
FIRE EXTINGUISHER
SS
STAINLESS STEEL
FIN
FINISHED)
STD
STANDARD
FOC
FACE OF COLUMN
STL
STEEL
FOS
FACE OF STUD
STOR
STORAGE
FT
FEET/FOOT
STRUCT
STRUCTURAL
FTG
FOOTING
SYM
SYMBOL
FURR
FURRING
T
TREAD
FURN
FURNACE
T*G
TONGUE AND GROOVE
GA
GAGE
TOB
TOP OF BEAM
GALV
GALVANIZED
TOC
TOP OF CURB/CONCRETE
GYP
GYPSUM (BOARD)
TOP
TOP OF PAVEMENT / PLATE
HDR
HEADER
TOS
TOP OF STEEL/SLAB
HM
HOLLOW METAL
TOW
TOP OF WALL
HORIZ
HORIZONTAL
TYP
TYPICAL
HT
HEIGHT
UNO
UNLESS NOTED OTHERWISE
INSUL
INSULATION
VCT
VINYL COMPOSITE TILE
INT
INTERIOR
VERT
VERTICAL
MAX
MAXIMUM
W
WEST, WIDTH, WASTE
MECH
MECHANICAL
W/
WITH
MFR
MANUFACTURER
W/O
WITHOUT
MIN
MINIMUM
ND
WOOD
MISC
MISCELLANEOUS
NH
WATER HEATER
MTL
METAL
WTR
WATER
SYMBOLS
A
ELEVATION /
FIN FLR__q� DATUM TARGET /
+ 8'-0 PROPERTY LINE DC I �B INT/EXT ELEV
CORNER \ A-6
WALL SECTION
A-5 BUILDING SECTION
' NORTH ARROW
NEW WINDOWS
O SMOKE
DETECTOR
CARBON
OC MONOXIDE
DETECTOR
NEW DOORS 311 EXHAUST FAN
Al REVISION KEY
MATERIALS KEY
EARTH ® WOOD - CONTINUOUS
BLOCKING / SHIM
CONCRETE
as
BRICK, CMU STEEL
RIGID INSULATION GWB, PLASTER
GATT INSULATION PLYWOOD
ENERGY CODE NOTES
WHERE INSULATION CAN BE ADDED TO THE EXISTING
STRUCTURE, BUILDING ENVELOPE COMPLIANCE METHOD
SHALL USE PRESCRIPTIVE APPROACH. BUILDING ADDITION
SHALL CONFORM TO THE 201E ENERGY CODE TABLE 402.1.1.
AND 402.1.3. ASSEMBLIES SHOWN MEET THE FOLLOWING
REQUIREMENTS. IF A CONDITION IS NOT SHOWN USE
MINIMUM STANDARDS AS INDICATED BELOW.
ROOFS: R-38ci (vaulted)
ATTICS: R-4P
WALLS: R-21 or R-13+R-7.5ci
FLOORS: R-30
SLAB ON GRADE FLOORS: R-10 for 24"
OPAQUE DOORS: U-0.30
WINDOWS: U-0.30
architect
LEED AP
1612 NW 73rd St
Seattle, WA 98117
phone: 206.794.2960
.1--he', comcast.net
L
O
a
W
CD
CD
W
o�a
i
..
Cl)
U. O
p
Ln E
W
Project
Project Engineer:
8827 REGISTERED
ARCHITECT
AR 'ON VANVLIET
STATE OF WASH INGTON
Revisions:
Sheet Title:
GENERAL INFO
SITE FLAN
FLAN N07 S
RECEIVED
Nov 16 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Scale: AS NOTED
Date: 11 / 10/23
Drawn By: I IJ\/
Checked By: r1JV
Al mO
1 of 3
I
C::1
AS BUILT / DEMO PLAN - LOWER LEVEL
SCALE: 3/16" = 1' -0"
I
I
AS BUILT / DEMO PLAN - MAIN LEVEL
SCALE: 3/16" = 1'-0"
architect
LEED AP
1612 NW 73rd St
Seattle, WA 98777
phone: 206.794.2960
m}vanviiet@eomeast.net
L
O
LU
LU
a
V
■
O
O
00
O
O
}' Q
i
..
Ja
iTL O
O
�
ti w
W
Project #: 23006
Project Engineer:
8827 REGISTERED
ARCHITECT
m 7v��J Vav�v i-i
MARK JON VANVLIET
STATE OF WASHINGTON
Revisions:
Sheet Title:
AS BUILT FLANS
IDE�10 FLANS
Scale: AS NOTED
Date: 11/10/23
Drawn By: I IJV
Checked By: I" IJV
A2mO
2 of 3
ENLARGED FLOOR PLAN - LOWER LEVEL
SCALE: 3/4" = I'-0''
i►
FLOOR AREA TO BE REMOVED
39" DIA OPENING IN FLOOR -
PATCH SUBFLOOR AND CARPET AT
OPENING. PROVIDE PAINTED GWB
BETWEEN FLOOR AND CEILING
BELOW
ENLARGED FLOOR PLAN -MAIN LEVEL
SCALE: 3/4'' = 1'-0"
III
LnFN
n J
GR
PLMWD INFILL
W/ FINISH FLR
C TO MATCH (E)
Fni
L_
SISTER NEW
2X10 RIM JOIST
PLANTER
- I
5
i
ENLARGED FRAMING PLAN - MAIN LEVEL
1 SCALE: 3/4" = 1'-0"
NOTE: VERIFY ALL CLEARANCES AND
DIMENSIONS WITH ELEVATOR MANUFACTURER
DRAWINGS AND SPECIFICATIONS
CEILING /
J� MAIN LEVEL
HEAD
NEW
FIVE
ELEVATOR
PVE ELEVATOR
HEAD IN REMOTE
LOCAT 1 ON
SECURE TOP OF
ELEVATOR A/
MANUF SUPPLIED
CABLES
GREAT ROOM o
I
C0
CUT JOIST AND
SECURE TO NEW
BEAM WITH JOIST
HANGERS (SEE
FRAMING PLAN)
L (E) 2X10 JOISTS
@ 16" O.C.
°
NEW 4X10 DF#2 BEAM
PAINTED GWB
CIRCULAR WRAP @
OPENING
i
FA1 I I LM ROOM
(E) 4'' CONC
SLAB
R_LEVEL _ — O-------- ----- --
8'-10y4" D ad a a a
(VERIFY) a
o '
Ell :mmmm
D
ELEVATOR SECTION
SCALE: 3/4'' = 1'-0"
architect
LEED AP
1612 NW 73rd St
Seattle, WA 98777
phone: 206.794.2960
mjvanvliet@eomeast.net
L
0
LLI
LLI
CD
13
CD
0
04
00
�
0�
a
L
0
E
MO
ti W
Project #: 2300�
Project Engineer:
8827 REGISTERED
ARCHITECT
VV1Le,
MARK JON VANVLIET
STATE OF WASHINGTON
Revisions:
Sheet Title:
ENLARGED
FLANS, FRA, I NG
FLAN SECS ON
Scale: AS NOTED
Date: 11/10/23
Drawn By: I IJ\/
Checked By: MJV
A3mO
3 of 3