Loading...
APPROVED BLD2023-1443+MANUF SPECS+11.10.2023_4.03.22_PM+3894720TYPICAL SETUP ATTIC VIEW "A -A" SCALE 2:1 " NOTE: (1) INTERMEDIATE CYLINDER IS CUSTOM MADE AS FLOOR THICKNESS MAY VARY FROM HOME TO HOME. �2 INTERMEDIATE CYLINDER IS CUSTOM MADE AS ROOM HEIGHT MAY VARY FROM HOME TO HOME. 03 MINIMUM ALLOWABLE HEIGHT ® MINIMUM ALLOWABLE HEIGHT AS SHOWN FOR THIS TYPE OF INSTALLATION INTERNAL DIAMETER OF CABIN WITHOUT THE COLUMNS IS 32" AND THE INTERNAL CABIN HEIGHT IS 6-5" © DOOR WIDTH IS 23 1/2" r"""""YYAk!mr, 'I'bYLf1i'f"nS 1............ The following ocumen a Ion s a e available on - site for the building inspector: ■ ! ! ® COE APPROVED ARCHITECTURAL PLAN SET : ■ ❑ COE APPROVED STRUCTURAL PLAN SET ■ ❑COE REVIEWED CALCULATION PACKET ' ! ❑ ENERGY CREDIT WORKSHEET ■ ❑SITE PLAN 0 99/16 ; : ❑ CIVIL PLAN : ® Manufacture Spec. Plans : MAX. OPENING OF DOOR 90 DEGRESS L ..........:: ::o: 0:o::::n: i iiPiiTii : ii2i ............. OPTION: REMOTE LOCATION OF HEAD UNIT 011 CONTROL 34"x21"+3" FTYP. OF 2 PANEL 4" PVC LINE 5^xv°ya ATTIC 122 t O 00 12"t 0 2ND FLOOR A A INTERMEDIATE O _I O � O 11 GROUND FLOOR APPROVED ALL WORK SUBJECT OBTAIN ELEVATOR PLANS MUST BE TO FIELD PERMIT FROM ON JOB SITE INSPECTION FOR STATE LABOR & CODE COMPLIANCE INDUSTRIES DETAIL "A" SCALE 2-1 (TYPICAL OF FLOOR PENETRATION) CEILING/FLOOR Information contain herein is the property of Pneumatic Vacuum Elevators LLC. No reproduction /��\ PNEUMATIC or disclosure of this information may be made by the /1V recipient to any person or organization without the VACUUM ELEVATORS LLC written consent of Pneumatic Vacuum Elevators LLC. INTERMEDIATE // L­JRECEIV 37" Nov 16 20: 3911 CITY OF EDMOND DEVELOPMENT SER% DEPARTMENT ntions I Article Nod Reference TYPICAL HOME INSTALLATION FOR A 2STOP ELEVATOR Designed by Scale Drawing No. Rev Date HIS1:1 D-TYP-H-01 1 07/22/11 X li 1111 4ilANfa9] Bali BLD2023-1443 TYPICAL BALC❑NY M❑UNT TYPICAL TR❑UGH EL❑❑R Doc.No.A003-001 Rev.A Rev. date:03-01-2019 NOTES CEILING/ELDER SEE TYPICAL 0 INSTALL CABLE CEILING/ELDER BRACKET NSTALLEDR BETWEEN ® STTUDMN AND FLooRING lo 0 3'-1" 1939,80mml 3'-3" 1990,60MMI INTERMEDIATE INTERMEDIATE 0 3'-1" C939,80mml OUTSIDE DIAMETER OF C990,60mml ELEVATOR EINISHED OPENING DIAMETER by 314MIN. 1-1Y2' MAX. �--- Cut Here EE�E CITY OFEDMONDS EVELOPMENT SERVICES DEPARTMENT Ewzw o Co z w 57 m Qw °J m M <Z EXAMPLE INS i i__raTI❑N TYPICAL INSTALLED CABLE co M (� m 029 9/16' (750 89r1N) It BALCONY CABLE BALCONY CABLE a � 0 21) � 50 CU V O O CLJ L� MAX, OPENING ❑E D❑❑R 90 DEGREES REVISION AND PRINT RECORD REV. BY DESCRIPTIEIN DATE FOR R L INITIAL LAYOUT 1L/18/19 MARKS CD o (U TOLERANCES UNLESS OTHERWISE SPECIFIED 1' (1.00) 25.4 MM OR LESS ±1/32 (.031)J93 MM OVER 1' (100) 254 MM LESS THAN 12' (1200) 304,80 MM ±1/16' (.0625) 159 MM OVER 12' (12.00) 304.80 MM LESS THAN 60' (60.00) 1524 MM ±1/8' (125) 3.18 MM OVER 60' (60,00) 1524 MM TO 120' (12000) 3048 MM ±1/4' (.250) 6,35 MM q A / �d n EPENING [IF D111IR 90 :DEGREES PNEUMATIC VACUUM ELEVATORS LLC 12630 NW 4-10 AVE Fa MEDLEY, FL. 92 (305) 884-1091 Fax (305) 884-1092 �►/! ELEVATOR O CD JOB NAME BALCONY EXAMPLES CU LF) LOCATION: 12602 NW 115th AVEMEDLEY, EL. 3318? MAX, ❑PENING ❑E D❑❑R 90 DEGREES SCALE NTS DRAWN BY RYDER LLOYD EINALS : 12/18/2015 CHECKED BY J C RELEASED BY CUSTOMER#:XX jPlIRDER #n XX BALC❑NY M❑UNT SAMPLE 1 JBALCENY HEUNT SAMPLE 2 TYPICAL TR❑UGH TL❑❑R HEUNT SAMPLE JJEB #BALC❑NY EXAMPLESSHEET#1 [IF 2 Fkit�PNEUMATIC pve® VACUUM ELEVATORS 12602 NW 1151h Avenue, Miami, FL 33178 Phone: 305-884-1091 Fax: 305-884-1092 ELECTRICAL REQUIREMENTS The following are the electrical requirements for a 2, 3, and 4stop elevators, model series PVE30 & PVE37 ➢ 220VAC (no exceptions 220VAC must be provided, 210 VAC or 230VAC is not acceptable, if installation does not have 220vac on a regular basis, a voltage regulator or transformer must be installed by home owner). Voltage fluctuations are not covered by the warranty. ➢ 1 phase ➢ (L.1, L2, Ground) ➢ 30amp ➢ Primary disconnect is to be provided by home owner. ➢ Electrical termination point is at top of elevator. If a split unit is used electrical termination will be on top of head/split system. ➢ If installing a phone line a phone jack is to be provided near the power supply line, but isolated. ➢ A 4ft power cord and plug is provided on top of elevator or head/split system for easy of connecting. The provided plug is manufactured by Pass & Seymour or comparable substitute: Catalog Number Page (PDF) 11Rating A IG11 ating V t50 Description Cord Diameter NEEMA Config. o. 3869 30150 ngled Plug, Black 56 - 1.1 in.�16-30P/6-50P ➢ Home owner / electrician needs to provide 220VAC, 1phase, 30amp electrical outlet as shown below (Pass & Seymour or comparable substitute): 220VAC, 1phase POWER OUTLET Straight Blade Devices Power Outlet Receptacles & Plu 20,30 5 Pass & Seymour O legrand Catalog Number Rating A. Rating V. Usage ��NEMA Receptacle/Plug Config and Description AL/CU No. 3801 30 250 6-30 Flush Receptacle It is strongly recommended that the electrician contact PVE before starting work. J��W PNEUMATIC VACUUM ELEVATORS LLC PVE 3 7 Installation Requirements The below requirements are for the vacuum elevator model PVE37. The external diameter of the PVE37 is 37" (933mm). Standard Model Split Unit Model - Minimum height required at the ground floor is 92" (2,34 m). All requirements for the split unit model (remote location of head unit) are the same as the standard model except for the - Minimum required height at the upper floor is 107" (2,70 m). following... - Diameter of finished through floor hole must be 39" (0.99 m). - When installing a three or four floor elevator, all openings' circular perforations should be perfectly aligned. The electric feed shall be 220VAC single phase through an independent line of conductors of AWG N° 10 (6mmZ); there shall be ground connection and a thermo-magnetic switch of 30A to be used exclusively for the elevator. The electrical supply is to be near the head (elevator's top portion) and it is required to leave the female electrical receptacle at the top center of the elevator. - Minimum required height at the upper floor is 97" (2,47 m). - Required space for remote location of head unit in attic or adjacent closet is 34" L x 24" W x 24" H (.86m x 0.61m x .61m) - Remote location of head unit can be accommodated up to 30 linear feet (10 m) away from the elevator. - Split unit connections require two 4" (10cm) PVC pipes to run the distance from the top of the upper floor cylinder split plate to the remote location of the head unit. - It is strongly recommended that a Buck Boost or voltage - Air supply to split unit has to be drawn from interior of stabilizer be installed along with the electrical work to prevent residence (proper housing of head unit and air duct to interior any damage to electrical components due to voltage fluctuation. of home required) housing of unit in attic should be a minimum of 6" greater on all sides than equipment. - When installing the elevator, consider the total dimensions, as a small room will generate a higher noise level. Therefore, it is not advisable to install the split motor in a very small facility. - There must be an opening to make way for the cylinders of 39" (0,95 m) in diameter and of 92" (2,34 m) in length down to the ground floor. This access may be through door or window openings. - Install a hook to bear 1800lbs at the ceiling where the elevator is to be installed to lift the cylinders. If it is impossible to install this hook, the minimum height at the last level shall be at least 109" (2,75 m). In no case must the perforation of the ceiling be less than 2" (5cm) from the wall, in order to allow for the installation tripod. 39' minimal 2' - Electrical power supply to be provided within direct access to remote location of head unit. SPLT modal c Vacuum Pump's no% :4- L x 24- W x 24- H o- PVC Pipes PVE37 Technical Specifications &I p pve General: • External cylinder diameter: 37" (940mm) • Rated Load: 450 lbs. (205 kg) • Speed: 30 fpm (.15 ms) • No pit required. Bottom level floor must be 100% level as elevator rests on existing floor. • No hoistway required. • Minimum overhead clearance: o Standard Unit (turbine motors located on top): 107" (2,719mm) o Split Unit (turbine motors located remotely): 97" (2,464mm) • Penetration required to install through floors and ceilings: 39" (991 mm) Mechanical Requirements • 220V, 60/50 Hz, 30amp single phase power supply • 5 turbine motors located in pump box using a total of 5KW Cabin: • Entrance width opening: 201/2 " (521mm) • Internal cabin height: 79" (2007mm) • Internal cabin diameter: 29 '/z" (750mm) • Automatic LED lighting and cabin fan • Door openings: same side (in -line) and walk through (180'). o All doors are hinged on top left, with door swing to the left, from inside the cabin. ■ Door Height: 77 3/4 " (1,975mm) ■ Height to top of Door closer: 79 1/2" (2,020mm) o Each landing level specified will include only one door. • 24 Volt electrical circuits with all controls in cabin • Push button call controls with precise leveling at each landing. Safety: • Automatic descent to ground level at safety speed in the event of a power failure. • Mechanical emergency brakes within two inches of freefall in vacuum loss or catastrophic failure. • Electromechanical interlocks at each landing • Alarm system and telephone (optional) Pneumatic Vacuum Elevators Technical Specifications Model PVE 37 02010