Loading...
APPROVED BLD BLD2024-1280+Architectural_Plan+9.11.2024_9.35.10_AM+4492946Property Information Site Address: 15925 75th PI W Edmonds WA 98026 Owners: Olivia and Max Gattuso Project Type: Interior remodel to 1971 MCM single family residence Legal Description: MEADOWDALE BEACH BILK 030 D-00 - LOT 7 & N 30 FT OF LOT 8 Assessor Parcel Number: 00513103000700 Zoning: 111 Single Family Residence - Detached (RS-8 / Single Family Urban 2) Setbacks: Side 7'-6", Rear 15'-0", Front 25'-0" Building Height: 25-0" Proiect Team Shoegnome Architects 1035 NE 95th St Seattle WA 98115 Phone: 206.504.3075 E-mail: jared@shoegnome.com Contact: Jared Banks , AIA BTL Engineering 19125 North Creek Parkway NE, Suite 203 Bothell, WA 98011 Phone: 425.814.8448 E-mail: Eric.Dann@btleng.net Contact: Eric Dann, PE/SE Site Plan SCALE:1/8" = 1'-0" Applicable Codes - 2021 IRC - International Mechanical Code (IMC) - Uniform Plumbing Code (UPC) - National Fuel Gas Code (NFPA 54) - 2021 International Fuel Gas Code - 2021 Washington State Energy Code -Washington State Ventilation & Indoor Air Code No change to building footprint or increase in size of conditioned space Path to Primary Entrance I o Ico -------------------- - - - ----------------------- -- I ------------- ---------------------- I I I ❑ I I 46-2 1 /4" , I I YI U (II N Front yard _I C:I LL I q NI I N � I I I I I CY) N I I I I , - N I I I I N I I N 45-1 1 /4" Energy (WSEC) Compliance path: prescriptive, 2021 WSEC Energy Code. Requirements applicable to this project: Vertical glazing: U .30 minimum Exterior wall: R-20+5 or 13+10 minimum Below -Grade: 10/15/21 int + 5TB Ceiling: R-60 minimum; R-38 single rafter Floors R-30 minimum Air leakage testing per WSEC R402.4 Air leakage not to exceed 7 air changes/hour for homes existing prior to the 2009 WSEC and shall be tested as such. A written report of the test results, shall be signed by the testing party and provided to the building inspector, prior to call for final inspection. Form available at: http://www.energy.wsu.edu/BuildingEfficiency/EnergyCode.aspx Duct testing per WSEC R403.3 Supply and return ducts located outside the conditioned space shall be insulated to an R-value of not less than R-8 for ducts 3" in diameter or larger and not less than R-6 for ducts smaller tahn 3" in diameter. Ducts shall be leak tested in accordance with WSU RS-33, using the maximum duct leakage rages specified. A written report of the results shall be signed by the party conducting the test and provided to the code official. Ventilation Ventilation shall comply with WA State VIAQ code WAC 51-52-403.8. Ventilation to be design build and consist of source specific exhaust fans, supply of outdoor fresh air intake to all habitable rooms through outdoor air inlets &/or mechanical air exchanger system, such as an HRV unit. All details to be design build and permitted by the mechanical subcontractor. General Notes 1. All work shall conform to all applicable codes and ordinances. 2. Do not scale drawings: use calculated dimensions only. Verify existing "as -built" dimensions as req'd. All dimensions are to face of stud unless noted otherwise. 3. Verify all rough -in dimensions and locations for equipment, fixtures etc. Provide all blocking, buck -outs, backing and jacks required for installation. 4. All wood in contact with concrete to be pressure treated. 5. All flashing to be galvanized, galvalume or factory finish to be approved by architect and owner. 6. Contractor shall verify all existing conditions prior to initiating any portion of the work. 7. Provide all protection, shoring and bracing as required by site conditions in order to maintain a safe job site and protect components to remain. 8. Stair and guardrail openings to be less than 4". 9. Tight line all affected drainage to approved drainage system. 10. All framing to be properly caulked, sealed, gasketed or otherwise treated to minimize air infiltration prior to sheathing and finishing. 11. All (new) smoke detectors to be hardwired to home's electrical system. 12. If subsurface water is encountered at any point, contact the owner's geotechnical engineer for recommendations before proceeding. T-6" Side yard setback — _ — _ — _ — _ — - -, N i ---------- a' , Existing asphalt driveway , I Deck (248 sq ft) Deck (102 sq ft) AC unit _ — 4 — - i �-11" BI-D" I 29, Covered Rear yard \ Front Porch (70 sq ft Yi CU o I �I o CIDI 15925 75th PI W of N MI 1971 two-story single family �I residence w/ basement I' (1,224 sq ft) existing footprint o I of I �I 0I I I �I � I TCI " , Q)I O °I I cI I J � CIO �I — — — — — — — — T-6" Side yard setback co r inl CD 35-11 " I, 22'-6" I I I I I I I I I I I I I I I I I ;A,I _.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._..� 1 WHERE ADDITIONS OR ALTERATIONS REQUIRE A PERMIT 1 TO BE ISSUED INTERCONNECTED SMOKE ALARM AND CO j 1 DETECTORS THROUGHOUT THE DWELLING IS REQUIRED. 1 1 REFER TO 2021 IRC R314 AND R315 FOR MORE 1 INFORMATION. ■ _ ■ _ ■ ■ _ ■ _ ■ ■ _ ■ _ ■ ............... ■ _ ■ ON ■ ■ _ ■ ON ■ J 1 1 BTAIN ELECTRICAL I ' PERMIT FROM ■ STATE LABOR & ' i INDUSTRIES r I• 1_■�■ 1 .................._■■_■_■■_■_■7 ._.1 . ■ NO ■ ON ■ ■ _ ■ ON ■ ■ _ ■ ON ■ ■ _ ■ ON ■ ■ _ ■ ON ■ ■ _ ■ ON ■ ■ _ ■ ON ■J ■ i I 'OBTAIN 1 A SEPARATE •. • I PLUMBING PERMIT 1 , FROM THE CITY OF • • ' 1 EDMONDS. it • I 1 ly■_■■_■_■■_■_■■_■_■■_■_■■_■_■■ ......... I ALL WORK SUBJECT TO FIELD INSPECTION FOR .4ODE COMPLIANCE ai a-O M 0 4' 8' 16' Sheet Index Cover Sheet, Site Plans, Permit Requirements A001 Cover Sheet and Site Plan A002 Demolition Lower and Main Level Plans A003 Demolition Upper Level Plan A004 Schedules Plans A101 Lower and Main Level Plans A102 Upper Level Plan and Building Section Interior Elevations A201 Lower Level Interior Elevations A202 Main Level Interior Elevations A203 Upper Level Interior Elevations A204 3D Views Electrical E001 Electrical Lower and Main Level Plans E002 Electrical Upper Level Plan 1 CONSTRUCTION & DEMOLITION i MATERIAL MANAGEMENT 1 1 1 PER THE REQUIREMENTS OF IRC APPENDIX Y APPLY TO 1 THIS PROJECT. PROVIDE THE REQUIRED REPORTS 1 INCLUDING THE FOLLOWING: 1 1 ■ SALVAGE ASSESSMENT FORM 1 ■ WASTE DIVERSION REPORT 1 ■ SEPARATE CONTAINERS 1 APPROVED PLANS MUST BE ON JOB SITE City Of Edmonds Building Department Work INTERIOR REMODEL Address ----------------- 15925 75TH PL W ------------------------- Owner ------------------------- GATTUSO ------------- Approved Date 10/22/2024 L Building Official Permit Number BLD2024-1280 ❑ a 1 1hTSESVII ❑ ❑ J ❑ ❑ a North Vicinity Plan not to scale 001100 0101010 1 101010101 1 01010010100101 01010101010101 10010010110001 101010111011 101010111 Shollegnome Architects 1035 NE 95th St Seattle WA 98115 206.504.3075 www.shoegnome.com Gattuso Remodel 15925 75th PI W Edmonds, WA 98026 Project Number: 23016 Drawings and Specifications as instruments of service are and shall remain the property of the Architect. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Architect. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Architect will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. © 2024 - Shoegnome Architects RECEIVED Sep 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11137 REGISTERED AR HITECT JARED E BANKS STATE OF WASHINGTON ISSUED: 09/11/2024 - Permit Set Cover Sheet and Site Plan A001 Printed: 9/11 /24 I I I I I I I I I I I I I I I I ----------- I I � � ' I � ' � I � ' I � I I I I I I I I I I I I I I I I � I I � � � I I I ' I � � I ' I I I I I ' I I I I I I I I a k ' ' I I I I I L— I I I ' I — ----------- Lower Level SCALE:1/4" = 1'-0" 0 2' 4' 8' Demo existing window, typ. .mo existing flooring :mo existing bathroom _--__ __ ________ I .YYYYYYYYYYYYYYYYYYYYYYYYYYYYYYYS29 I L— — — — — — — — — _ — _ _ _ = — J - — - — - Walls, Doors, Windows, and Fixtures to be demolished shown dashed/red. Demo existing ceiling and floor finish as required. 2 A002 Main Level SCALE:1/4" = 1'-0" 0 2' 4' 8' 001100 0101010 1 10101101101 1 01010010100101 01010101010101 10010010110001 101010111011 101010111 no Sholegnome Architects 1035 NE 95th St Seattle WA 98115 206.504.3075 www.shoegnome.com Gattuso Remodel 15925 75th PI W Edmonds, WA 98026 Project Number: 23016 Drawings and Specifications as instruments of service are and shall remain the property of the Architect. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Architect. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Architect will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. © 2024 - Shoegnome Architects RECEIVED Sep 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11137 FREGISTERED AR HITECT DARED E BANKS STATE OF WASHINGTON ISSUED: 09/11/2024 - Permit Set Demolition Lower and Main Level Plans A002 Printed: 9/11 /24 r I I- -— ---- I 1 I I I I I I I I ________________r_ - .- - - - - - - - - - -IIIIIIIIIIIII _____ I .______IIII -_--_--_--_--_--_--_--_--_--_--_--_--_--_--_--_--_--_--_- -_- -_- -_- -_- -_--_--_-_- --_--_--_--_-_- I . - I I 0)o I I 0 00 Ir---- -- - - — -- ----- - —_ - -=---w -=--=------=--=---_- I I I I I I I I I I I I I I Exposed 2x6 car decking ceiling/roof, no attic I I 1= .--------- --- — — — — — — — — � � � � _ ------------------------------=---------=---_— I I I I I I I I I I . r I I I I I I I I I I Ir------------------__---------------_ _ L UDDer Level I n � rJr•�1, n � rl��l+ n I--- ------ ___I — — — III I III III III III rr III III III III I I I I I I I I JI I I III I I I I I II I I ._— _- - ---- — . IIIII --------------------------- - — --.-- ° III IIIII LLLIJ 7, III III III LL I ---ll I II I I r -----L�-- -- .-- — — . =— -- a -- L-_ III it I I I = I - =:-. ----- .- --- III II lii ii I I --,I I I I I Demo existing bathroom SCALE:1/4" = 1'-0" 0 2' 4' 8' 001100 0101010 1 101010101 1 01010010100101 01010101010101 10010010110001 101010111011 101010111 no Sholegnome Architects 1035 NE 95th St Seattle WA 98115 206.504.3075 www.shoegnome.com Gattuso Remodel 15925 75th PI W Edmonds, WA 98026 Project Number: 23016 Drawings and Specifications as instruments of service are and shall remain the property of the Architect. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Architect. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Architect will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. © 2024 - Shoegnome Architects RECEIVED Sep 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11137 REGISTERED AR HITECT JARED E BANKS STATE OF WASHINE ISSUED: 09/11/2024 - Permit Set Demolition Upper Level Plan A003 Printed: 9/11 /24 Vertical Glazing Window and Door Schedule (conditioned space) Label Operation Type Width Height Quantity Egress Tempered Note hk- -11[km M -AOL W201 Casement 2'-11 1/2" 3'-5 1/2" 1 Yes No W202 Fixed 5'-5 1/2" 3'-5 1/2" 1 No No W 101 Casement 1'-11 1/2" 5-5 1/2" 1 W 102 Fixed 3'-5 1/2" 5-5 1/2" 1 Not Ganged D001 Garage Door 10'-0" 7'-0" 1 W001 Sliding Window 5-5 1/2" 3'-5 1/2" 1 W002 Sliding Window 5-5 1/2" 3'-5 1/2" 1 W103 &L Fixed 5'-51/2" 1'-11 1/2" 1 W104 Sliding Window 5'-5 1/2" 3'-5 1/2" 1 W203 Awning 1'-111/2" 1'-111/2" 1 91 W204 Awning 1'-111/2" 1'-111/2" 1 W205 Awning 1'-111/2" 1'-111/2" 1 i VA Window Notes All windows, doors, and skylights to be NFRC Certified - Series/type or equal - Maximum U-value to be .3 or better - Interior and exterior - Match Existing - Hardware - TBD - No grills, unless noted on the schedule - Glass - Low-e or better - Screens @ operable windows Yes Yes No Yes No No Yes No Yes No 0 Yes No No N No No No Yes Skylight Schedule Label Operation Type Width Height Quantity Tempered Note S301 Fixed 2'-0" 2'-0" 1 Yes verify size with existing opening S302 Fixed 2'-0" 2'-0" 1 Yes verify size with existing opening K Skylight Notes -All skylights to be NFRC Certified - Minimum U-value to be .5 or better - Inboard pane of glass to be laminated glass (with not less than a 30-mil (0.76 mm) polyvinyl butyral interlayer), outboard pane to be tempered. Type Awning View \ Dimensions 1'-11 1/2"x1'-11 1/2" D W203, W204, W205 Position Type View Dimensions ID Note Exterior Garage Door 10'-0"x7'-0" D001 Window Types Casement Casement Fixed / / / 1'-11 1/2"xS-51/2" 2'-11 1/2"x3'-51/2" 3'-13/4"x2'-61/2" W 101 W201 301 Interior Window, match existing Interior Inswing Door 0 2'-6" x 6'-8" 001, 001 a, 102 Interior Interior Inswing Door Inswing Door 0 0 2'-8"x6'-8" 2'-8"x6'-8" 005 007 Insulated, 20 min fire rated, self -closing device Fixed 3'-5 1 /2" x 5'-5 1/2" W102 Interior Outswing Door / / / / / 0 2'-0"x6'-8" 002, 104 Fixed 5-5 1 /2"x 1'-11 1/2" -1- Door Types Interior Outswing Door \ \ \ \ \ \ 0 2'-8" x 6'-8" 004 Interior Door and Window Schedule Label From Room To Room Lower L 001 Lower Hall Bathroom A 002 Linen Bathroom A Operation Type Inswing Door Outswing Door Width AIM Height Hardware Set Quantity Note Privacy 1 2'-6" 6'-8" 2'-0" 6'-8" Passage 1 004 Storage Lower Hall Outswing Door 2'-8" 6'-8" Passage 1 005 Lower Hall Bedroom 4 Inswing Door 2'-8" 6'-8" Privacy 1 006 Closet 4 Bedroom 4 Sliding Door 5'-0" 6'-8" Passage 1 007 Garage Lower Hall Inswing Door 2'-8" 6'-8" Privacy 1 008 Under Stair Storage Lower Hall Outswing Door 2'-6" 6'-8" Passage 1 010 Mechanical Media Room Pocket Door 2'-6" 6'-8" Passage 1 Main LevelIL 001a Bedroom 3 Bathroom B Inswing Door 2'-6" 6'-8" Privacy 1 101 b Bathroom B Bathroom B Shower Door 2'-4" 6'-0" Privacy 1 102 Entry Bedroom 3 Inswing Door 2'-6" 6'-8" Privacy 1 103 Closet 3 Bedroom 3 Outswing Door 2'-4" 6'-8" Passage 1 104 Coats Entry Outswing Door 2'-0" 6'-8" Passage 1 Upper Level A=6 -4m IML Alk 203 Closet 1 Bedroom 1 Sliding Door 10'-0" 6'-8" Passage 1 206a Bathroom C Bedroom 1 Pocket Door 2'-6" 6'-8" Privacy 1 206b Bathroom C Bedroom 2 Pocket Door 2'-6" 6'-8" Privacy 1 301 Catwalk Bedroom 1 Fixed 3'-1 3/4" 2'-6 1/2" N/A 1 17 Sliding Window n» 5-5 1 /2" x 3'-5 1/2" A /AAA 5'-5 1 /2" x 3'-5 1/2" W001, W002, W 104 Interior Interior Interior Interior Outswing Door Outswing Door Pocket Door Shower Door 0 0 0 / / 2'-6" x 6'-8" 2'-4" x 6'-8" 2'-6" x 6'-8" 2'-4" x 6'-0" 008 103 010, 206a, 206b 101 b verify size with existing sliding glass shower opening door Interior Sliding Door 51-011x6-8" 006 Interior Sliding Door 101-01Ix6'-8" 203 insulated, 20 min fire rated, self -closing device verify size with existing opening sliding glass shower door Interior Window, match existing 001100 0101010 1 101010101 1 01010010100101 01010101010101 10010010110001 101010111011 101010111 E&id� � Sholegnome Architects 1035 NE 95th St Seattle WA 98115 206.504.3075 www.shoegnome.com Gattuso Remodel 15925 75th PI W Edmonds, WA 98026 Project Number: 23016 Drawings and Specifications as instruments of service are and shall remain the property of the Architect. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Architect. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Architect will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. © 2024 - Shoegnome Architects RECEIVED Sep 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11137 REGISTERED AR HITECT DARED E BANKS STATE OF WASHINGTON ISSUED: 09/11/2024 - Permit Set Schedules A004 Printed: 9/11 /24 Wall Legend New (color) New Exterior Wall 1111111=1 New Interior Wall 0 New Insulated Wall @ foundation _ New Foundation Wall Existing (grayscale) ® Existing Exterior Wall ® Existing Interior Wall 0 Existing Foundation Wall Patches at existing walls shown in color 1 1 GUARDS SHALL NOT HAVE AN OPENING FROM THE WALKING SURF NCE TO THE REQUIRED GUARD HEIGHT THAT WILL ALLOW THE PASSAGE OF A 4" SPHERE IN ACCORDANCE WITH 2O21 IRC R312.1.3. 1 New W10x30 exposed beam Provide 3/8" steel plate base. Minimum 3" weld x 3/16" in two places, plate to post. Secure plate to post (or squash blocks) below w/ (4) SDS25300. Dining Looking East SCALE:1/4" = l'-0" 1 1 PROVIDE A HEAT DETECTOR IN 1 Top of half wall at foundation to be flush with window sill. Bottom of window sill @ +/-40" above THE GARAGE AS REQUIRED concrete floor 1 PER 2021 IRC R315. i Closet4 6'-5" 6'-5" 2'-0" x 6'-7" Egress W001 ----------- D001 I I I I I I II I I� i k I , I, I� I' i i i k I, i I' ' I I I I I I I I I I a II I', I I ' I I I I I I I I I I L — I i I ' I iI I ' ' ------------ v Garage 007 \ 15'-1" x 23'-3" / / 12'-10" \ New (2) 2 x 8 header at new openings in existing — bearing wall, typ. Door to garage to be equipped with self -closing device New 4x8 post below new steel post @ existing bearing wall Extend to underside of sheathing New tankless water heater, verify location 04 ch X 5 Smoke Existing post and beam I I I W4x13 post (align with existing post above) Window and door headers to be insulated with a minimum of R-10 insulation window and (2) 2 x8 header (header @ 6-9 1/2") 14' Combination"-8" x 6'-8" f smoke/CO detector I I w/ owner Under Stair Storage 008 Min. 1/2" gyp. bd. at walls and 5/8" 9'-0" x 3'-0" Type X gyp. bd. at ceiling separating the garage from the dwelling. 1 Insulate walls between garage and dwelling 1 Existing gas furnace in new location, verify with HVAC design Lim 00 Media Room V-6" x- +/-4'-6 1/2" iT— N o09 1 24'-1" x 15'-4" Provide drain for Mechanical future bar sink 010 (verify location with a'-s° x 11'-2° owner and architect) --------- - x N Egress ��I I I fT Hil co I I W002 New window and (2) 2 x 8 header (header @ 6'-9 1/2") 10'-8 1/2" Top of half wall at foundation to be flush with window sill. Bottom of window sill @ +/-40" above Fill exposed exterior wall cavities with insulation, typ. concrete floor Lower Level SCALE:1/4" = 1'-0" Storage 004 5-0" x 11'-0" 2'-8" x 6'-8" Lower Hall 003 18'-8" x 10'-7" `o 2' 4" 2'-6" x 6'-8" 80 N x Cl) CD (V . 1 � 1 ID ,I I A201 3 0 2' 4' 8' Plumbing stack for kitchen and bath above Soffit at beam and plumbing wall to face of beam Wall Construction - 1/2" gyp bd - 2x4 w/ 1/2" space behind - 3 1/2" sprayfoam insulation (R-21) - Concrete (Existing) 42" vanity Bathroom A 001 5'-0" x 11'-9" Toilet at existing stub location 32" x 60" tub at existing stub location 0 2' 4' 8' (4) 3/4" diameter bolts @ beam gage Steel beam per pla SDS25312 each flange bearing plate mn per plan Steel Beam / Steel Post Connection SCALE: 1 1 /2"= V-0" 0 6" 12" 18" New 4x8 5 Dining A101 107 15'-6" x 11'-6" New W10x30 exposed beam, painted black A102 � ------------------- Stop wall at bearing for assumed beam above oM 4 a A101 Living W4x13 post, painted black 108 15'-6° x 11'-2" (align with existing post above) Wood post per pla Provide 3/8" steel plate base. Minimum 3" weld x 3/16" in two places, plate tom post. Secure plate to post (or squash blocks) below w/ (4) SDS25300. d T Den 109 15'-6" x 8'-10" Steel Beam / Wood Post Connection SCALE: 1 1 /2"= V-0" Jew window at existing header 14'-1" d beam per plan ')25312 each flange Wood post per plan 0 6" 12" 18" 8'-8' II W101 W102 it I Kitchen 1 2 3 13'_9., x 15'_5„ 1 20 1 it 1 PROVIDE A LOOP VENT F 1 PROPOSED SINK AND AN 4'-0" 4'-4" 1 i i PROPOSED DISHWASHEf �R. 1 i � � N o `e - ---------1--- -- ----------- -- -- - --- 2 A102 CID N I 1 I I A202 11 Plumbing stack for kitchen and bath above I I III T-13/4" 10'-4" 10 I 19'-9" x 1 V-6" I to I 00 II � II Existing handrail _ I M +, N co N •X O I M m New window and header I (header @ 6'-9 1/2") I Existing guard/handrail I T-21/2" T-21/2" Combination smoke/CO detector 73 C I 3'-10 3/4" 1 I Smoke W 104 _--------- Egre _ — New window and (2) 2 x 8 header (header @ 6'-9 1/2") 21'-6" Provide access to back of washer/dryer from closet Main Level SCALE: 1 /4" = V-0" h8 Bathroom B 101 5'-6"x11'-6" N Ii0 0o 71, X 19 I (2) 2 x 8 header @ existing bearing wall I Washing U 1 I (verify) I I Dryer o �, I 6 C' 3" I ar 5'-1 " I X A202 7 I I 8 __ -- -1I------ closet 3 103 Mono pitch tile shower floor 2'-6" x 2'_9" A AI rll 0 2' 4' 8' 001100 0101010 1 101010101 1 01010010100101 01010101010101 10010010110001 101010111011 101010111 Shoegnome Architects 1035 NE 95th St Seattle WA 98115 206.504.3075 www.shoegnome.com Gattuso Remodel 15925 75th PI W Edmonds, WA 98026 Project Number: 23016 Drawings and Specifications as instruments of service are and shall remain the property of the Architect. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Architect. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Architect will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. © 2024 - Shoegnome Architects OR THE AIR GAP FOR THE IN THE ISLAND. ! i RECEIVED Sep 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11137 REGISTERED AR HITECT JAR E BANKS STATE OF WASHINGTON ISSUED: 09/11/2024 - Permit Set Lower and Main Level Plans Al 01 Printed: 9/11 /24 Wall Legend New (color) New Exterior Wall 0= New Interior Wall 0 New Insulated Wall @ foundation _ New Foundation Wall Existing (grayscale) ® Existing Exterior Wall ® Existing Interior Wall 0 Existing Foundation Wall Patches at existing walls shown in color New clerestory window to match r Smoke detector (wall mounted) I I I I ------------ --------------------------------------------r-- I- I I Align with edge of window above I I Built-in or furniture I I ------------ ------------------------------- -------------r-- —.—.—.—.—.—.—.—.—.—.—.—.—.— I I I I I I I I I I ------------------ --------------------------------------�- ---------------- - I I Combination smoke/CO detector (wall mounted) I I ------------ -------------------------------------------- -- I I I I I I I I I I ------------ --------------------------------------------T- I`- I I I I Smoke detector (wall mounted) I I 1— —_--- -—.—.—.—.—.----------- L Upper Level SCALE:1/4" = 1'-0" stops below windows New (2) 2x8 header @ 6'-11 1/2" head height Egress /Equal 2'-1" Equal W201EqualW202 t 91 _r I _ - - ---- ---------- ----- — _ - ---- ---- ----- --JI awning window w/ new III 1 (2) 2x8 header to match III Ganged Unit N existing head height o M III � I III 3 III set1 III Clo>4 � I 2 A203 Bedroom 1 '_0" x 12'_6" 0 201 III o 13'-4" x 14'-4" -,I 1 III New window at existing header III III I N I III 5 1/2" � I III g'_0 vaulted ceiling = 4'-6 3/4" Ilk llli �c, 2'-6" x 6'-8" Bathroom C a 1 N 00 III M �N 1 7'-4" z012'-11" 4 E M C° _--------_-----7 - wall to wall double vanity 2x6 wall, if required 5 k for plumbing 1 )" I I — J e I 8 A203 6 ° - N 15" deep cabinets CO _ N p I? Cl) existing skylightLO ° location---] ° Closet 2 c 205 I IIII 3'-0" t I ,I --- -- - --- -- - — ----- - ---- - JI IIII 1'-6 3/4" I 204 III --------------------------------------------------- ---I —.—.—.—.—.—.—.—.—.—.—.—.—.—.—. _ I I I I I J N M 7 awning window w/ new header to match existing head height 9 SAFETY GLAZING AS PER 2021 IRC R308.4. ' .. = .. M.. = .. = .. = .. I �A203 10 11 Existing T-0" x 6'-0" sliding window sill height @ 43" AFF 0 2' 4' 8' 2 A102 Building Section SCALE: 1 /4" = 1'-0" Preliminary Area Label Room Name Area Lower Level 001 Bathroom A 52.48 002 Linen 3.75 003 Lower Hall 114.09 004 Storage 57.32 005 Bedroom 4 145.64 006 Closet 4 13.25 007 Garage 343.04 008 Under Stair Storage 28.17 009 Media Room 292.36 010 Mechanical 47.54 Main Level 101 Bathroom B 77.44 102 Bedroom 3 122.00 103 Closet 3 6.88 104 Coats 5.00 104 Entry 172.71 106 Kitchen 214.21 107 Dining 177.29 108 Living 177.77 109 Den 160.84 Upper Level 201 Bedroom 1 213.87 203 Catwalk 150.82 203 Closet 1 25.04 204 Bedroom 2 169.10 205 Closet 2 16.69 206 Bathroom C 98.37 2,885.67 ft2 0 2' 4' 8' 001100 0101010 1 101010101 1 01010010100101 01010101010101 10010010110001 101010111011 101010111 Shoeignome Architects 1035 NE 95th St Seattle WA 98115 206.504.3075 www.shoegnome.com Gattuso Remodel 15925 75th PI W Edmonds, WA 98026 Project Number: 23016 Drawings and Specifications as instruments of service are and shall remain the property of the Architect. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Architect. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Architect will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. © 2024 - Shoegnome Architects RECEIVED Sep 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11137 REGISTERED AR HIT ECT JARED E BANKS STATE OF WASHINGTON ISSUED: 09/11/2024 - Permit Set Upper Level Plan and Building Section Al 02 Printed: 9/11 /24 FOR REFERENCE ONLY Toilet paper holder Bathroom A Looking North Bathroom A Looking East Towel bar Curtain rod Wall tile Shower niche, verify size and location with tile pattern 32" x 60" tub at existing stub location Tile base Curtain i Shower niche, ve size and location w tile patt( Wall Bathroom A Looking South Curtain rc�' Shower hee )nce vel ring set for relocated :er heater floating vanity SCALE:3/8" = 1'-0" 0 2' 4' 6' A201 SCALE:3/8" = 1'-0" 0 2' 4' 6' A201 SCALE:3/8" = 1'-0" 0 2' 4' 6' A201 SCALE:3/8" = 1'-0" 0 2' 4' 6' �� W001 Egress Wood sill c c c Bedroom 4 Looking North SCALE:3/8" = 1'-0" 0 2' 4' 6' 001100 0101010 1 1010,0101 1 01010010100101 01010101010101 10010010110001 101010111011 101010111 Shoegnome Architects 1035 NE 95th St Seattle WA 98115 206.504.3075 www.shoegnome.com Gattuso Remodel 15925 75th PI W Edmonds, WA 98026 Project Number: 23016 Drawings and Specifications as instruments of service are and shall remain the property of the Architect. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Architect. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Architect will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. © 2024 - Shoegnome Architects RECEIVED Sep 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11137 REGISTERED AR HIT ECT JARED E BANKS STATE OF WASHINE ISSUED: 09/11/2024 - Permit Set Lower Level Interior Elevations A201 Printed: 9/11 /24 FOR REFERENCE ONLY Living Room windows 2� Kitchen Looking North T2) SCALE: 3/8" = 1'-0" 9" deep by 45" wide shelves, centered on pe (verify size and spaci Filler panel I match existing I T-0" 2'-0" 3'-0" 2'-0" 1' 2„ sink dishwasher Kitchen Looking West A202 ) SCALE: 3/8" = 1'-0" " s '� Bathroom B Looking North A202 / SCALE: 3/8" = 1'-0" '1 o Entry Looking East A202 SCALE: 3/8" = 1'-0" 0 2' 4' 6' W8x13 exposed black Plugmold Under cabinet lighting Filler panel Baseboard to match existing 4'-0" 2" Verify full height cabinet depth with refrigerator selection Kitchen Lookina East an Peninsula 3 Kitchen Looking South SCALE: 3/8" = V-0" Tile backsplash— Wrap counter material up wall Filler panel-----* 0 2' 4' 6' A202 SCALE: 3/8" = 1'-0" Venthood ALT. butcher block countertop @ this elevation Filler panel Wall Ovens I electric cooktop 1"J 5 Kitchen Looking East 0 2' 4' 6' A202 SCALE: 3/8" = 1'-0" Towel rin V-6" L 4'-0" L +/- 2'-11 1 /4" L T-0" 7 Bathroom B Looking East 0 2' 4' 6' A202 SCALE:3/8" = 1'-0" I ^--`-- - '- -- stair hall 0 2' 4' 6' head lower lower aper �\ 2'-6" T-1" 1" Filler panel Glass shower wall w/ sliding door Counter depth fridge (verify) 9" deep by 45" wide shelves, ✓vith owner) 3x13 exposed am, painted black tx13 post, inted black rify that owner can ,nfortably reach light itches from both sides peninsula deep bookshelf 0 2' 4' 6' 24" deep cabinet 12" deep cabinet +/-2 1/4" rii' Kitchen Looking South 0 2' 4' 6' A202 SCALE: 3/8" = 1'-0" s Bathroom B Looking South 0 2' 4' 6' A202 SCALE: 3/8" = V-0" Corner shelves- Shower controls_ (thermostatic valve) Towel bar- 0 2' 4' 6' Align top of opening with top of door trim (flush opening with ceiling if no dropped beam required) ee 001 a 0 O 9 Bathroom B Looking West 0 2' 4' 6' A202 SCALE: 3/8" = 1'-0" Tile base 0 2' 4' 6' 001100 0101010 1 101010101 1 01010010100101 01010101010101 10010010110001 11010111011 101010111 Shoegnome Architects 1035 NE 95th St Seattle WA 98115 206.504.3075 www.shoegnome.com Gattuso Remodel 15925 75th PI W Edmonds, WA 98026 Project Number: 23016 Drawings and Specifications as instruments of service are and shall remain the property of the Architect. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Architect. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Architect will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. © 2024 - Shoegnome Architects RECEIVED Sep 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11137 REGISTERED AR HITECT JARED E BANKS STATE OF WASHINE ISSUED: 09/11/2024 - Permit Set Main Level Interior Elevations A202 Printed: 9/11 /24 FOR REFERENCE ONLY Bedroom 1 Looking South SCALE:3/8" = 1'-0" " 5 \ Bathroom C Looking North A203 % SCALE: 3/8" = 1'-0" Align top of closet with New interior window 2 Bedroom 1 name Looking West 0 2' 4' 6' A203 SCALE:3/8" = 1'-0" Horizontal light Towel ring ,,,, 6'-8" 5'-5 3/4" 6 Bathroom C Looking East 0 2' 4' 6' A203 SCALE:3/8" = 1'-0" Horizontal light Corner shelves Shower controls (thermostatic valve) Wall tile Corn SIC 3 Bedroom 1 Looking North 0 2' 4' 6' A203 SCALE:3/8" = 1'-0" -' Towel D .E 7 Bathroom C Looking South 0 2' 4' 6'lmmmmmn� ..9 A203 SCALE:3/8" = 1'-0" Horizontal light Showerhead Hand shower Hand shower controls Glass shower wall Wall tile 4 Bedroom 1 0 2' 4' 6' A203 SCALE:3/8" = 1'-01, Heated towel rack +/- 1 1 /8" I 1 1 • r 8 Bathroom C Looking West 0 2' 4' 6' A203 SCALE:3/8" = 1'-0" 9 Bathroom C Shower Looking North 10 Bathroom C Shower Looking East 11 Bathroom f "' ' ' " A203 SCALE:3/8" = 1'-0" 0 2' 4' 6' A203 SCALE:3/8" = 1'-0" 0 2' 4' 6' A203 SCALE:3/8" = 1'-0" 0 2' 4' 6' 9" deep shelves U) 0 C: L 0 �0 V E 0 O 0 0 U 0 Q 0 furniture 0 2' 4' 6' ght (above and lets ed I rack t paper )r 1 IIG case 0 2' 4' 6' 001100 0101010 1 101010101 1 01010010100101 01010101010101 10010010110001 101010111011 101010111 Shoegnome Architects 1035 NE 95th St Seattle WA 98115 206.504.3075 www.shoegnome.com Gattuso Remodel 15925 75th PI W Edmonds, WA 98026 Project Number: 23016 Drawings and Specifications as instruments of service are and shall remain the property of the Architect. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Architect. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Architect will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. © 2024 - Shoegnome Architects RECEIVED Sep 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11137 REGISTERED AR HIT ECT JARED E BANKS STATE OF WASHINE ISSUED: 09/11/2024 - Permit Set Upper Level Interior Elevations A203 Printed: 9/11 /24 FOR REFERENCE ONLY 001100 0101010 1 101010101 1 01010010100101 01010101010101 10010010110001 11010111 Oil 101010111 Shoeignome Architects 1035 NE 95th St Seattle WA 98115 206.504.3075 www.shoegnome.com Gattuso Remodel 15925 75th PI W Edmonds, WA 98026 Project Number: 23016 Drawings and Specifications as instruments of service are and shall remain the property of the Architect. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Architect. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Architect will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. © 2024 - Shoegnome Architects RECEIVED Sep 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11137 REGISTERED AR HIT ECT JARED E BANKS STATE OF WASHINE ISSUED: 09/11/2024 - Permit Set 3D Views A204 Printed: 9/11 /24 FOR REFERENCE ONLY � I i I I i I LID E Smoke detector Combination 3 smoke/CO detector A ,c� Door switch j� I I / I ; I Di I / I / � D A� IA�� �d/ car A Ii 9 it \ i A Ili A \` AL \ _ II -� L I I � O A ---------- it rn D31 Lower Level SCALE:1/4" = V-0" Level 2 electric car charger, verify location with owner. 40-amp dedicated 208/240-volt circuit shall be installed in the electrical panel. The circuit shall be fully wired and terminate at a junction box, receptacle outlet, or electric vehicle charging equipment. Door switch Bath fan on humidistat switch 0 2' 4' 8' 2 E001 Main Level SCALE: 1 /4" = V-0" F (D cc .\ rr I' LL Verify that owner can comfortably reach light switches from both sides of peninsula Window I E E I _ I �A / / � I U I LL I I cD G 3: � I 1 � I A � c_4J G�-- I I I I I � I , � G I A DDD ` I A Combination smoke/CO detector 0 2' 4' 8' 001100 010101019 101010101 1 01010010100101 01010101010101 10010010110001 101010111011 101010111 Shoegnome Architects 1035 NE 95th St Seattle WA 98115 206.504.3075 www.shoegnome.com Gattuso Remodel 15925 75th PI W Edmonds, WA 98026 Project Number: 23016 Drawings and Specifications as instruments of service are and shall remain the property of the Architect. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Architect. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Architect will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. © 2024 - Shoegnome Architects RECEIVED Sep 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11137 REGISTERED AR 'IT DARED E BANKS STATE OF WASHINE ISSUED: 09/11/2024 - Permit Set Electrical Lower and Main Level Plans E001 Printed: 9/11 /24 FOR REFERENCE ONLY Bath fan on humidistat switch Upper Level SCALE:1/4" = 1'-0" 0 2' 4' 8' Lighting Schedule Label Quantity Description Location A 22 Recessed can Bathroom A, Bathroom B, Bathroom C, Kitchen, Lower Hall, Mechanical, Media Room B 1 Sconce Bathroom A C 2 Under cabinet light Kitchen D 4 Linear LED light Closet 1, Closet 4, Linen, Under Stair Storage E 3 Decorative ceiling mounted fixture Bedroom 3, Bedroom 4, Media Room F1 1 Hanging decorative fixture Dining F2 2 Hanging decorative fixture Bedroom 1, Bedroom 2 G 3 Pendant, small Kitchen K 2 Lighted mirror Bathroom B, Bathroom C M 1 Fan with light kit 41 001100 0101010 1 101010101 1 010, 0010100101 01010101010101 10010010110001 101010111011 101010111 Shoeignome Architects 1035 NE 95th St Seattle WA 98115 206.504.3075 www.shoegnome.com Gattuso Remodel 15925 75th PI W Edmonds, WA 98026 Project Number: 23016 Drawings and Specifications as instruments of service are and shall remain the property of the Architect. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Architect. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Architect will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. © 2024 - Shoegnome Architects RECEIVED Sep 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11137 REGISTERED AR HIT ECT JARED E BANKS STATE OF WASHINGTON ISSUED: 09/11/2024 - Permit Set Electrical Upper Level Plan E002 Printed: 9/11 /24