APPROVED BLD BLD2024-0091+Architectural_Plan+1.19.2024_3.11.11_PM+4010239
SOUTH ELEVATION OF RESIDENCE FIRE -DAMAGED SIDING FIRE-DAMAGED/REMOVED INTERIOR FINISHES IN LIVING ROOM J* f FIRE -DAMAGED FINISHES IN BEDROOM GENERAL NOTES: GENERAL CONDITIONS: 1. DO NOT SCALE DRAWING6- 2. REPETITIVE FEATURES MAY BE DRAWN OR CALLED OUT ONCE, BUT SHALL 5E COMPLETELY PROVIDED AS IF DRAWN IN FULL. 3- ALL WORKMANSHIP SHALL BE OF THE HIGHEST QUALITY AND SHALL BE IN ACCORDANCE WITH ALL MANUFACTURERS' SPECIFICATIONS, DIRECTIONS AND RECOMMENDATIONS. THE WORK SHALL ALSO 5E IN STRICT CONFORMANCE WITH INDUSTRY STANDARDS AND COMPLY WITH SOUND ENGINEERING AND CONSTRUCTION PRACT I GE S- 4. ALL WORK SHALL 5E PERFORMED IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL LAWS, AND IN ACCORDANCE WITH CURRENT CODE REQUIREMENTS. 5- THE CONTRACTOR SHALL COORDINATE ALL REQUIRED LOCAL JURISDICTION INSPECTIONS AND SPECIAL INSPECTIONS. THE CONTRACTOR SHALL PROVIDE COPIES OF THE INSPECTION REPORTS TO THE OWNER &. ALL NEW AND/OR REPLACEMENT MATERIALS SHALL BE EQUAL OR BETTER IN KIND AS EXISTING MATERIALS. -1. PLUMBING, MECHANICAL AND ELECTRICAL WORK (AS REQUIRED FOR REPAIR WORK) TO 5E FILED UNDER SEPARATE PERMITS AND SHALL BE BIDDER DESIGNED. PLUMBING, MECHANICAL AND ELECTRICAL REPAIR DESIGN TO 5E PERFORMED BY LICENSED AND QUALIFIED PLUMBING, MECHANICAL AND ELECTRICAL CONTRACTORS, ALL NEW MECHANICAL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE WASHINGTON STATE ENERGY CODE. 5. CONTACT THIS OFFICE AT (20&) 251-1500 IF ANY ADDITIONAL DAMAGE IS FOUND OUTSIDE THIS SCOPE OF WORK DURING DEMOLITION OR ANY VARIATIONS TO THE SITE OR EXISTING BUILDING ARE FOUND DURING THE CONSTRUCTION WORK - SITE CONDITIONS SAFETY AND DEMOLITION: 9- THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONDITIONS AT THE JOB SITE, INCLUDING THE SAFETY OF ALL PERSONS AT THE JOB SITE DURING THE PERFORMANCE OF THE WORK. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT 5E LIMITED TO NORMAL WORKING HOURS. 10- THE CONTRACTOR SHALL PROVIDE ACGEPTABLE SAFETY AND SECURITY MEASURES AND SHALL MAINTAIN SAFETY AND SECURITY AT THE JOB SITE DURING THE ENTIRE COURSE OF THE PROJECT. 11- THE REQUIRED AND/OR IMPLIED DUTY OF PACIFIC ENGINEERING TECHNOLOGIES, INC., TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE DOES NOT, AND IS NOT INTENDED TO, INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES IN, ON, OR NEAR THE CONSTRUCTION SITE. 12, ALL WORK SHALL BE PERFORMED DURING NORMAL BUSINESS HOURS IN ACCORDANCE WITH THE LOCAL JURISDICTIONAL REQUIREMENTS. 13. THE CONTRACTOR SHALL PROVIDE ITS OWN DUMPSTER FOR CONSTRUCTION DE5RI6- 14. PROPERLY PROTECT OR CAP ALL UTILITIES THAT MIGHT 5E DISTURBED DUE TO DEMOLITION ACTIVITY. 15. PRIOR TO GENERAL/SELECTIVE DEMOLITION, THE GENERAL CONTRACTOR SHALL OBTAIN THE PERMISSION OF THE OWNER TO DETERMINE WHETHER HAZARDOUS WASTES OR ASBESTOS IS PRESENT IN DEMOLITION DEBRIS. SHOULD HAZARDOUS MATERIALS OR ASBESTOS BE FOUND IN DEMOLITION DEBRIS, THE CONTRACTOR SHALL LEGALLY CONTAIN SUCH MATERIAL AND DISPOSE OF OFF SITE AT AN APPROVED DUMP SITE AFTER OBTAINING THE OWNER'S PERMISSION TO DO SO. 1&- COORDINATE ALL DEMOLITION ACTIVITIES WITH THE OWNER 1-1- THE CONTRACTOR SHALL TRANSPORT AND DISCARD IN A LEGAL MANNER ALL CONSTRUCTION DEBRIS AND REMOVED ITEMS NOT INTENDED FOR REUSE. 15. INSPECT CONCEALED SPACES UNCOVERED DURING THE DEMOLITION PHASE FOR ADDITIONAL DAMAGE. 19- REMOVE AND REPLAGE ALL MOISTURE DAMAGED FINISHES INCLUDING DAMAGED THERMAL AND SOUND INSULATION. CONSTRUCTION: 20. ALL SUCH PRODUCTS AND MATERIALS SHALL 5E INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS, INDUSTRY STANDARDS AND CODE REQUIREMENTS. THE CONTRACTOR SHALL KEEP A SET OF THESE INSTRUCTIONS ON THE SITE DURING REPAIRS RELATING TO THAT WORK. 21- PROVIDE WEATHER -RESISTIVE / AIR BARRIER BEHIND WALL CLADDING IN ACCORDANCE WITH IRC R703.2 AND R-103.1.1 AND THE WASHINGTON STATE RESIDENTIAL ENERGY CODE R402.4 AND TABLE R402.4.1.1. WEATHER -RESISTIVE / AIR BARRIER SHALL BE CONTINUOUS AND ALL JOINTS SHALL BE TAPED OR SEALED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 22. PROVIDE FLASHINGS FOR EXTERIOR BUILDING COMPONENTS IN ACCORDANCE WITH I RG R1 03.4. 23- INSTALL ROOFING COMPONENTS IN ACCORDANCE WITH IRC CHAPTER 9- 24- THE CONTRACTOR SHALL VERIFY THAT ALL WATERPROOFING COMPONENTS ARE COMPATIBLE WITH EACH OTHER, I.E. SEALANTS AND BACKER ROD, SEALANTS, AND SELF ADHESIVE (PEEL 'N' STICK) MEMBRANE, ETC. 2E% ALL NEW WINDOWS AND EXTERIOR DOORS SHALL COMPLY WITH THE CURRENT EDITION OF THE WASHINGTON STATE ENERGY CODE. 26- WINDOWS, SLIDING GLASS DOORS AND DOORS SHALL BE INSTALLED WITH PENETRATION FLASHINGS AND IN ACCORDANCE IRC R�03.4 AND WITH ASTM E 2112- 21 NEW THERMAL INSULATION MUST COMPLY WITH THE CURRENT EDITION OF THE & 0.0' ± I I I I I I +� LANDSCAPING I I cn i +� F__ i +1 I I I I I@ I I I I I I I I I I I I I I I I I LU I I I � I d +1 GONG. LANDSCAPING DRIVE N , ,00 M 240TH ST. SW WORK THIS PERMIT, SHOWN SHADED S 1 TE PLAN � NOTE - THE THE INFORMATION ON THIS SITE PLAN IS SCALE: 1" = 20'-0" SCHEMATIC AND HAS BEEN DERIVED FROM THE SITE PLAN INFORMATION ON RECORD WITH 6NOPOMI6H COUNTY, AERIAL PHOTOGRAPHS AND SITE VISIT. New and replaced materials shall meet 2018 International Residential Code standards. All exposed exterior wall, floor, or ceiling assemblies shall be insulated to fullest extend feasible. Smoke alarms shall be interconnected and located in each bedroom and outside each sleeping area. A minimum of one per floor. Electrical, plumbing and mechanical work has not been included with this permit. Please apply for all applicable permits. APPROVED WASHINGTON STATE ENERGY CODE ENERGY CODE. 25. PROVIDE MINIMUM R-3 PER INCH FOR EXISTING EXPOSED CEILING, WALL, OR FLOOR PLANS MUST BE CAVITIES WASHINGTON STATE ENERGY CODE R503.1.1 EXCEPTION 2- 29- ALL VENTILATION OPENINGS SHALL BE SCREENED EXCEPT DRYER VENTS, ALL VENT OPENINGS SHALL HAVE LOUVERS. 30. WHERE WINDOWS OR DOORS ARE TEMPORARILY REMOVED OR D ISCARDED, THEY SHALL BE RE -INSTALLED OR INSTALLED BY THE END OF EACH DAY. 31- SMOKE SEAL EXISTING FRAMING THAT IS TO REMAIN, ON JOB SITE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES SCOPE OF WORK SUMMARY TYPE: FIRE DAMAGE REPAIR THE PURPOSE OF THESE DRAWINGS IS TO SHOW REPAIRS FOR THE DAMAGE CAUSED 5Y THE RECENT FIRE AT THE SUBJECT RESIDENGE IN EDMONDS, WASHINGTON. THE SCOPE OF WORK IS TO REPAIR THE FIRE DAMAGE TO THE HOUSE IN -KIND, THERE ARE NO ALTERATIONS OR ADDITIONS. MOST OF THE STRUCTURAL DAMAGE IS LIMITED TO AN ISOLATED AREA OF ROOF SHEATHING AT THE SOUTH ROOF OVERHANG. INTERIOR FINISHES, INSULATION, AND FIXTURES ARE BEING REMOVED AND REPLACED AS REQUIRED. THERE IS NO INCREASE IN THE EXISTING BUILDING FOOTPRINT, SQUARE FOOTAGE OR HEIGHT, EXCLUSIONS: NO REVIEW HAS BEEN MADE OF THE ADEQUACY OF THE EXISTING FRAMING MEMBERS. ARCHITECTURAL DETAILING SUCH AS, BUT NOT LIMITED TO: ROOFING, WEATHER -RESISTIVE ASSEMBLIES, WATERPROOFING, EXTERIOR SIDING, FLASHING, VENTILATION, WINDOWS, DOORS, INSULATION, FIRE -RESISTIVE ASSEMBLIES, VAPOR RETARDERS, INTERIOR FINISHES, ETC. IS NOT INCLUDED IN THESE DRAWINGS. MECHANICAL, ELECTRICAL AND PLUMBING WORK IS NOT INCLUDED WITH THIS PERMIT AND SHOULD BE FILED UNDER A SEPARATE PERMIT. CI ' 381h St SW 00 2381h St SW D 99 Travelodge by Wyndham 1II1a4- T*a-iSmiSSlon ©Seattle North/Edmonds a T � O sewer Fnel,y� 9 Seattle Myer^.� � xnmg Se',;_e 9 �401h St SW 2401h St SW 240th St SW Careful Movers Wounded in 1994 - Schedube an Estimate Burlington D 36u" St SW 2401h St SW 2401h St S'1 Mathay-BaUmge• Park VICINITY MAP 0�"`ht, SCALE: N-T-S. ASSESSOR'S No.: 004r519002019Orp LEGAL DESCRIPTION: FRUITLAND ACRES TO LAKE 5ALLINGER 5LK 002 D-O5 - S 118FT OF E &OFT OF LOT 19 5U LD INCH DATA: JURISDICTION: CITY OF EDMONDS CODES: 2015 INTERNATIONAL RESIDENTIAL CODE WITH STATE OF WASHINGTON AMENDMENTS 2010 INTERNATIONAL EXISTING BUILDING CODE WITH STATE OF WASHINGTON AMENDMENTS ZONING: CG (GENERAL COMMERCIAL) OCCUPANCY: R-3 (SINGLE FAMILY RESIDENCE) CONSTRUCTION TYPE: V5 LOT SIZE: 0.10 ACRES BUILDING AREA: FIRST FLOOR: 960 50. FT - BASEMENT: 450 SQ. FT ATTACHED GARAGE 510 SQ. FT, SHEETINDEX SHEET 1 SITE PLAN, VICINITY MAP, PHOTOGRAPHS AND NOTES SHEET 1.1 NOTES SHEET 2 FLOOR PLANS AND SECTION ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department -------------- Work FIRE DAMAGE REPAIR ------------------------------------------------------------------------ --------------------- Address 8101 240TH ST SW ----------------------- ----------------------------------------------------------------------- Owner GRONVOLD --------------------------- Approved Date, 01 /24/2024 Building Official Elr�& ---------- Permit Number BLD2024-0091 ------------------------------------------------ 0 0 6 Z 0 w C1 tr O B u N � ILz, A z o 3 Z K. Q ,,tttt O ` UI 0 V C T Q 0 0 r- I N CID o� I O rp CD N I o 00 N N co 0 1") CD 0 N M cri� -- 00 Cn s� os 0 z 00 N T m° o �o � lV �66 r4 6 � v c o N >. o N v 4- 0 0 d) n.LU 1J— O Z Z U3: T OL Z 1J— RECEIVED LU � O Jan 22 CITY OF ED 024 NDS C DEVELOPMENT DEPARTM ERVICES NT 'n U VI I Uf Q Z z 1--L LU 1--1 O� z O V U BASEMENT/GARAGE 1/19/2024 23285 WD 01.dwg ALL INFORt CATION ON THIS DOCUMENT IS THE EXCLUSIVE PROPERTY OF PACIFIC ENGINEERING TECHNOLOGIES, INC. © COPYRIGHT 2024 U� Job No. 23205.00 IBUILDING ENVELOPE a:7PECIFI(::A I IO %5: ENERGY GODS: PROVIDE THERMAL INSULATION IN ACCORDANCE WITH 2O10 WASHINGTON STATE ENERGY CODE RESIDENTIAL PROVISIONS, IN ACCORDANCE WITH RESIDENTIAL TABLE R402.1.1 ATTIC/ROOF EXTERIOR WALL (EXISTING) RIM JOISTS HEADERS FLOORS OVER UNCONDITIONED SPACE ACCESS HATCHES AND DOORS HVAC DUCTS (ATTIC R402.4.4) EXHAUST DUCTS (ATTIC ) HOT WATER PIPES GLAZING DOORS R-49 (R-3 PER INCH OVER ROOF EAVE) R-15 (2x4 FRAMING) R-21 R-10 RIGID R-30 SAME AS SPACE AGGESSING R-S R-6 R-3 u = 0.30 MAX. u = 0.30 MAX. U-FACTORS SHALL BE DETERMINED IN ACCORDANCE WITH NFRC 100, PROVIDE MINIMUM R-3 PER INCH FOR ANY EXPOSED EXISTING FLOOR, CEILING OR WALL CAVITY. WINDOWS AND SLIDING GLASS DOORS (R402.4.3): WINDOWS SHALL HAVE AN AIR LEAKAGE RATE OF NO MORE THAN 0.3 CFM PER SQUARE FOOT WHEN TESTED IN ACCORDANCE WITH NRFC 400 OR AAMA/WDMA/GSA 101/1.,5.2/A440. EXTERIOR SWING DOORS (R402.4.3): EXTERIOR DOORS SHALL HAVE AN AIR LEAKAGE RATE OF NO MORE THAN 0.5 CFM PER SQUARE FOOT WHEN TESTED IN ACCORDANCE WITH NRFC 400 OR AAMA/WDMA/CSA 101/I.6.2/A440. VAPOR RETARDERS (R402.1.6): PROVIDE VAPOR RETARDERS IN ACCORDANCE WITH IRC R102.1 THE FOLLOWING LOCATIONS: • ON INTERIOR (HEATED) SIDE OF EXTERIOR WALLS VAPOR RETARDERS SHALL HAVE A PERM RATING OF LESS THAN OR EQUAL TO 1.0 (CLASS I OR 11) IN ACCORDANCE WITH ASTM E '96. VAPOR RETARDERS SHALL EITHER BE PROVIDED AS 6 MIL POLYETHYLENE SHEETING OR AS A PVA PAINT. ATTACH POLYETHYLENE SHEETING TO THE INTERIOR FACE OF WALL STUDS BY APPLYING A CONTINUOUS BEAD OF SEALANT TO EACH STUD. INSTALL POLYETHYLENE IN CONTINUOUS SHEETS AS MUCH AS POSSIBLE. WHERE LAPS DO OCCUR, THE LAPS SHALL BE 6" MINIMUM AND SEALED WITH TAPE OR SEALANT. CONTINUOUSLY SEAL BOTTOM AND TOP EDGES TO WALL AND CEILING TERMINATIONS. SEAL VAPOR RETARDER TO ANY CONDUIT, BOXES, PIPING OR OTHER ITEMS WITHIN THE WALL SYSTEM, REPAIR ANY TEARS OR PENETRATIONS OF VAPOR RETARDER WITH APPROVED TAPE PRIOR TO INSTALLATION OF DRYWALL. BAFFLES: (R402.2.3) PROVIDE A COMPOSITE (SOLID PLASTIC OR FOAM) BAFFLE FOR INSULATED AND VENTED ATTICS. BAFFLES SHALL MAINTAIN AN OPENING EQUAL OR GREATER THAN THE SIZE OF THE VENT. WITHIN ATTICS AND RAFTERS, THE BAFFLE SHALL EXTEND OVER THE TOP OF THE ATTIC INSULATION TO MAINTAIN A 1-INCH AIRSPACE. AIR LEAKAGE SEALING (R402.4 AND TABLE R402.4.1.1): THE FOLLOWING AREAS OF THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED, GASKETED, OR WEATHER-STRIPPED TO MINIMIZE AIR LEAKAGE IN ACCORDANCE WITH R402.4: • JOINTS AROUND WINDOWS/FENESTRATIONS AND DOOR FRAMES • JUNCTIONS BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALLS AT BUILDING CORNERS, BETWEEN WALLS AND STRUCTURAL FLOORS OR ROOFS, AND BETWEEN WALLS AND ROOF OR ROOF PANELS • OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH THE ROOFS, WALLS, AND FLOORS • RECESSED LIGHT FIXTURES AND SIMILAR OBJECTS THAT PENETRATE THE WALL OR CEILING FINISHES • ALL OTHER OPENINGS IN THE BUILDING ENVELOPE MECHANICAL VENTILATION: PROVIDE SOURCE SPECIFIC FANS IN ACCORDANCE WITH IRC SECTION M1505.4.4. PROVIDE MINIMUM EXHAUST RATES AS FOLLOWS: RANGE HOOD 100 GFM BATHROOMS 50 CFM (1.0 50NE MAX.) LAUNDRY ROOMS 50 CFM (1.0 SONE MAX.) EXHAUST DUCT TERMINATION LOCATIONS ON THE EXTERIOR OF THE BUILDING ARE TO BE LOCATED A MINIMUM OF 3'-0'' FROM WINDOW AND DOOR OPENINGS. STRUCTURAL NOTES: CODE: THE INTERNATIONAL RESIDENTIAL CODE (IRC) 2015 EDITION AND THE 2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC), WITH THE STATE OF WASHINGTON AMENDMENTS. LIVE LOADS: ROOF SNOW LOAD 25 PSF NAILS: NAILING SHALL BE IN ACCORDANCE W/ FASTENING SCHEDULE TABLES 11-13 IN ICC-ES EVALUATION REPORT E51R-153g PREPARED FOR THE INTERNATIONAL STAPLE, NAIL AND TOOL ASSOCIATION (ISANTA). ALL NAILS SHALL HAVE STANDARD SIZE ROUND HEADS UNLESS NOTED OTHERWISE ON THE DRAWINGS. NAIL LENGTHS AND DIAMETERS SHALL BE AS FOLLOWS: 106 3" x 0.131'' DIA. 106 COMMON 3" x 0.148" DIA. ALL NAILS EXPOSED TO WEATHER OR IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE NOT -DIPPED GALVANIZED PER ASTM A153-GLASS D. GENERAL WOOD FRAMING NOTES: 1. MINIMUM NAILING SHALL BE IN ACCORDANCE WITH FASTENING SCHEDULE TABLES 11-13 IN ICC-ES EVALUATION REPORT E6R-1539. 2. CURRENT IBC BUILDING CODES ARE AVAILABLE ONLINE FOR FREE PUBLIC ACCESS AT CODES.ICCSAFE.ORG. ROOF SHEATHING: APPLY BOARD SHEATHING TO MATCH EXISTING THICKNESS, NAILED WITH (2) 10cl NAILS AT EACH SUPPORT, AT OVERHANGS, APPLY Ix T4G SHEATHING TO MATCH EXISTING THICKNESS. NAIL NEW BOARD SHEATHING WITH (2) lOd NAILS AT EACH SUPPORT. DWELLING/GARAGE SEPAR T ION NOTES: DWELLING -GARAGE WALL AND CEILING SPECIFICATIONS: PROVIDE DWELLING -GARAGE SEPARATION IN ACCORDANCE WITH IRC R302.6 AND TABLE R302.6 AS FOLLOWS: WALLS: • WHERE HABITABLE SPACE IS PRESENT ABOVE THE GARAGE ALL GARAGE WALLS SHALL BE COVERED WITH NOT LESS THAN 1/2'' GYPSUM BOARD OR EQUIVALENT APPLIED TO THE GARAGE SIDE. • ALL STRUCTURES SUPPORTING FLOOR FRAMING SHALL BE COVERED WITH NOT LESS THAN 1/2'' GYPSUM BOARD OR EQUIVALENT. REFERENCE PLAN FOR LOCATION. • THE GYPSUM BOARD SHALL EXTEND FROM THE CONCRETE STEM WALL TO THE GYPSUM BOARD CEILING. • FASTEN WITH 1 1/4'' LONG ASTM C1002 TYPE W DRYWALL SCREWS AT 16" ON -CENTER CEILING: • THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE BY NOT LESS THAN 5/8" TYPE 'X' GYPSUM BOARD OR EQUIVALENT APPLIED TO THE GARAGE SIDE. • FASTEN WITH 1 1/4'' LONG ASTM C1002 TYPE W DRYWALL SCREWS AT 6" ON -CENTER DUCT PENETRATIONS: • DUCTS IN THE GARAGE AND DUCTS PENETRATING WALLS OR CEILINGS IN THE DWELLING FROM THE GARAGE SHALL BE NO, 26 GAUGE SHEET STEEL AND SHALL NOT HAVE OPENINGS IN TO THE GARAGE. PENETRATIONS: • THE ANNULAR SPACE AROUND PENETRATIONS THROUGH THE REQUIRED WALL OR CEILING GYPSUM SEPARATION SHALL BE PROTECTED WITH SEALANT IN ACCORDANCE WITH ASTM E136, AS REQUIRED BY IRC R302.11, ITEM 4. FIRE PROTECT ION NOTES: SMOKE ALARMS: SMOKE ALARMS SHALL BE INSTALLED THROUGHOUT THE ENTIRE BUILDING IN THE FOLLOWING LOCATIONS: • IN EACH BEDROOM. • IN THE IMMEDIATE VICINITY OUTSIDE EACH BEDROOM. • ON EACH FLOOR OF THE RESIDENCE. SMOKE ALARMS IN EXISTING BUILDINGS SHALL CONFORM TO REQUIREMENTS OF IRC SECTION R314 AND THE FOLLOWING SPECIFICATIONS: • ALARMS SHALL COMPLY WITH UL 21-1. • ALARMS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 12 AND MANUFACTURER'S RECOMMENDATIONS. • ALARMS SHALL BE HARD WIRED TO THE BUILDING ELECTRICAL SYSTEM AND BE EQUIPPED WITH BATTERY BACK-UP. • ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS. INTERCONNECTION OF THE ALARMS CAN BE MADE WITH PHYSICAL CONNECTIONS OR WITH LISTED WIRELESS CONNECTIONS. • SMOKE ALARMS SHALL NOT BE PLACED WITHIN 3 FEET OF A BATHROOM DOOR UNLESS NO OTHER LOCATION IS ACCEPTABLE. • IONIZATION SMOKE ALARMS SHALL NOT BE PLACED WITHIN 20 FEET HORIZONTALLY FROM A PERMANENT COOKING APPLIANCE. • PHOTOELECTRIC SMOKE ALARMS SHALL NOT BE PLACED WITHIN 6 FEET HORIZONTALLY FROM A PERMANENT COOKING APPLIANCE, CARBON MONOXIDE ALARMS: PROVIDE CARBON MONOXIDE ALARMS IN ACCORDANCE WITH THE IRC SECTION R315. • ALARMS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 120 AND MANUFACTURER'S RECOMMENDATIONS. • LOCATED IN THE IMMEDIATE VICINITY OUTSIDE EACH BEDROOM. • GARBON MONOXIDE DETECTORS SHALL BE LISTED IN ACCORDANCE WITH UL 2034. • CARBON MONOXIDE ALARMS CAN BE COMBINED WITH SMOKE ALARMS. COMBINATION CARBON MONOXIDE/SMOKE ALARMS SHALL BE LISTED IN ACCORDANCE WITH UL 2034 AND UL 211. HEAT DETECTOR: PROVIDE A HEAT DETECTOR RATED FOR THE AMBIENT OUTDOOR TEMPERATURES AND HUMIDITY IN GARAGES THAT ARE ATTACHED TO OR LOCATED UNDER DWELLINGS IN ACCORDANCE WITH IRC SECTION R314, HEAT DETECTORS SHALL BE INSTALLED IN A CENTRAL LOCATION AND IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. HEAT DETECTORS SHALL BE CONNECTED TO AN ALARM OR A SMOKE ALARM THAT IS INSTALLED IN THE DWELL ING, ALARMS AND SMOKE ALARMS THAT ARE INSTALLED FOR THIS PURPOSE SHALL BE LOCATED IN A HALLWAY, ROOM, OR OTHER LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION. DETECTORS SHALL BE HARD WIRED TO THE BUILDING ELECTRICAL SYSTEM AND BE EQUIPPED WITH BATTERY BACK-UP. 0 WINDOW SPEC«ICATI0N-5: THE NEW WINDOWS SHALL MEET THE FOLLOWING SPECIFICATIONS: 1. CONTRACTOR TO VERIFY THE SIZE OF THE EXISTING ROUGH OPENING PRIOR TO ORDERING THE WINDOWS. 2, THE ROUGH WINDOW OPENING SHALL BE SQUARE AND PLUMB. 3. WINDOWS SHALL: a. BE VINYL FRAMED, b. HAVE DUAL PANES, c. INSECT SCREENS FOR THE OPERABLE PANES, cl. LOW-E COATING, AND e. INTEGRATED NAIL FLANGES. 4. WINDOWS SHALL HAVE AIR INFILTRATION RATE OF NO MORE THAN 0.3 CFM PER O SQUARE FOOT 0.5 L/6/M2), WHEN TESTED ACCORDING TO NFRC 400 OR AAMA/WDMA/GSA 101/I.6.2/A440 BY AN ACCREDITED, INDEPENDENT LABORATORY AND LISTED AND LABELED BY THE MANUFACTURER (R402.4.3) 5. THE WINDOWS SHALL BE TEMPERED IN ACCORDANCE WITH THE SAFETY GLAZING REQUIREMENTS LISTED BELOW. 6. THE WINDOW CONFIGURATIONS, HARDWARE AND COLOR SHALL BE APPROVED BY Z THE OWNER PRIOR TO PURCHASE OF THE WINDOWS. -1. THE CONTRACTOR SHALL CLEAN THE INTERIOR AND EXTERIOR OF THE WINDOW AND FRAME AFTER THE REPAIR WORK IS COMPLETE. W C1 tr SAFETY GLAZING IN WINDOWS AND DOORS: O B SAFETY GLAZING SHALL BE IN ACCORDANCE IRC SECTION R305. GLAZING IN THE v �q N FOLLOWING LOCATIONS SHALL BE TEMPERED: (NOTED AS (T) ON FLOOR PLANS) Z 1. THE BOTTOM EDGE OF THE GLAZING IS WITHIN 60 VERTICALLY OR HORIZONTALLY c u o OF A BATHTUB OR SHOWER aNi t� 3 ° 2. GLAZING IN BATHROOMS, LL ALL INFORMATION ON THIS DOCUMENT IS THE EXCLUSIVE PROPERTY OF PACIFIC ENGINEERING TECHNOLOGIES, INC. © COPYRIGHT 2024 Lu U nu Ck hid C 0 0 r- co 0 N r')o 0 0m c� -- 00 0 oD 0 z_ 00 �f) N T RECEIVED Jan 22 1024 d OL I'l CITY OF ED NDS DEVELOPMENT ERVICES 1/19/2024 23285 WD 01.dwg Job No. 23205.00 2 0 0 PROVIDE 1" MIN. AIRFLOW ABOVE INSULATION, TYP. BAFFLE PER BUILDING ENVELOPE NOTES Ix FASCIA TO MATCH EXIST. VENTED SOFFIT TO MATCH EXIST. S C STORAGE e I I PROVIDE GWB AT BEAMS, POSTS, AND BEARING WALLS PER DWELL ING/GARAGE SEPARATION NOTES ON SHEET 1.1, SHOWN Jai STORAGE SA 15'-0"t 0 0 W POWDER EO LAUNDRY EF EF D HW 2i�x�s PROVIDE GWB AT EXTERIOR BASEMENT/GARAGE WOOD FRAMED WALLS AND CEILING FINISHES THROUGHOUT BASEMENT /GARAGE LEVEL PER DWELLING/GARAGE SEPARATION NOTES ON SHEET 1.1, SHOWN GARAGE HD SASE «lilt/GARAGE FLOOR FLAN SCALE: 1/4" = 1'-0'' EXIST. ROOF SHEATHING EXIST. ROOF RAFTER INSULATION PER BUILDING ENVELOPE NOTES EXIST. CEILING JOIST EXIST, WOOD FRAMED WALL SECTION ❑� SCALE: 3/4'' = 1'-O" 3 l EXIST. FULL HEIGHT CONC. WALL EXIST. PARTIAL HEIGHT CONC. WALL WITH EXIST. 2x WOOD FRAMED WALL ABOVE NOTES: 1. REMOVE AND REPLACE ALL INTERIOR FINISHES AND INSULATION 2. CONTRACTOR TO CONFIRM EXTENT OF WINDOW AND DOOR REPLACEMENT OM ®® LEGEND. SA SMOKE ALARM PER FIRE PROTECTION NOTES ON SHEET 1.1 CM CARBON MONOXIDE DETECTOR PER FIRE PROTECTION NOTES ON SHEET 1.1 HD G� HEAT DETECTOR PER FIRE PROTECTION NOTES ON SHEET 1.1 EXHAUST FAN PER BUILDING EF ENVELOPE NOTES ON SHEET 1.1 RH RANGE HOOD PER BUILDING ENVELOPE NOTES ON SHEET 1.1 HW HOT WATER HEATER NEW WINDOW, FIELD VERIFY ALL XxxXx SIZES, REF. WINDOW ® SPECIFICATIONS OF SHEET U FOR ADDITIONAL INFORMATION X NEW DOOR, FIELD VERIFY ALL )(c SIZES, REF. BUILDING ENVELOPE SPECIFICATIONS OF SHEET 1.1 FOR ADDITIONAL INFORMATION :i tt cm 0 �t OUTLINES OF ROOF ABOVE MAIN FLOOR PLAN SCALE: 1/4 = 1 -O 10'-011t REMOVE AND REPLACE APPROXIMATE EXTENT OF ROOF SHEATHING AT O.N. EXTERIOR SIDING TO BE REMOVED PER STRUCTURAL NOTES, AND REPLACED AS REQ'D TO SHOWN SHADED MATCH EXIST. 0 ly 6 z w C1 �r O 0 u N � �TT z z o,L 3= cYi i O Q Q 0 0 I N co O O 00 co u� O 00 O N �CD I o N N 0 0 KJ O 0 M N CO 0 I� C O L L O Z � O O Lo N N N RECEI ED Jan 22 024 CITY OF ED NDS DEVELOPMENT ERVICES 1/19/2024 23285 WD 01.dwg ALL INFOF4 IATION ON THIS DOCUMENT IS THE EXCLUSIVE PROPERTY OF PACIFIC ENGINEERING TECHNOLOGIES, INC. © COPYRIGHT 2024 Job No. 23205.00