Loading...
APPROVED BLD BLD2023-0648+Architectural_Plan+5.26.2023_8.14.14_AM+35709921102 12th Ave N 1102 12th Ave N, Edmonds The following documentation shall be available on site for the building inspector: '. X❑ COE APPROVED ARCHITECTURAL PLAN SET X❑ COE APPROVED STRUCTURAL PLAN SET COE REVIEWED CALCULATION PACKET ❑ ENERGY CREDIT WORKSHEET ❑ SITE PLAN ; CIVIL PLAN ■ ■ PROJECT TEAM ABBREVIATIONS OWNER: Michele Eddy A.F.F. ABOVE FINISHED FLOOR EA. EACH 1102 Ave Edmonds, WA 98020 ADJ. ADJUSTABLE ELEC. ELECTRIC HORIZ. HORIZONTAL PT. PAINT U.L. UNDERWRITERS LABORATORY spi2th (E) msspiffs150@gmail.com C ALUM. ALUMINUM ELEV./EL. ELEVATION HR. HOUR PLAS. PLASTER U.N.O. UNLESS NOTED OTHERWISE A.B. ANCHOR BOLT EQ. EQUAL IN. INCHES P.LAM. PLASTIC LAMINATE DRAFTING ATVAGA LLC ANOD. ANODIZED EQUIP. EQUIPMENT INCL. INCLUDING PL. PLATE VENT. VENTILATION TEAM: 170 WEST DAYTON ST, # 204 APPROX. APPROXIMATELY EXIST./(E) EXISTING INFO. INFORMATION PLYWD. PLYWOOD VIER. VERIFY EDMONDS, WA 98020 US ARCH. ARCHITECT EXP. JT. EXPANSION JOINT I.D. INSIDE DIMENSION PR. PAIR V.I.F. VERIFY IN FIELD GAYDAR HAMIDOV EXT. EXTERIOR INSUL. INSULATION R RADIUS VERT. VERTICAL ANNA SENCHENKO BTWN. BETWEEN INT. INTERIOR REC. RECOMMENDATION V.C.T. VINYL COMPOSITION TILE (E) anna@atvaga.com BLK. BLOCK, BLOCKING FT. FEET REINF. REINFORCED, REINFORCING BD. BOARD FIN. FINISH JT. JOINT REQ'D. REQUIRED W.P. WATER PROOF BLDG. BUILDING FLR. FLOOR JST. JST. REV. REVISION WWF WELDED WIRE FABRIC F.D. FLOOR DRAIN R.D. ROOF DRAIN W/ WITH CAB. CPT. CABINET CARPET FLUOR. FLUORESCENT LAM. LIN. LAMINATE LINEAR RM ROOM W/O WITHOUT PROJECT DATA: FTG. FOOTING R.O. ROUGH OPENING WD. WOOD C.B. CATCH BASIN FNDN. FOUNDATION L.P. LOW POINT C.T. CERAMIC TILE SEC. SECTION PROJECT CLG. CEILING GALV. GALVANIZED MFR. MANUFACTURER SIM. SIMILAR NUMBER: 2301-0004 CL. CENTER LINE GA. GAUGE M.O. MASONRY OPENING S SHEET C.O. CLEANOUT G.C. GENERAL CONTRACTOR MAT. MATERIAL S.C.AX. SOLID CORE PROJECT 1102 12TH AVE N CLR. CLEAR GL. GLASS MAXIMUM .C. SM SHEET METAL ADRESS: EDMONDS, WA 98020 COL. COLUMN GYP. GYPSUM MECH. MECHANICAL SPECS. SPECIFICATIONS CONC. CONCRETE MIN. MINIMUM S.S. STAINLESS STEEL PARCEL CMU. CONCRETE MASONRY UNIT HDCP. HANDICAPPED MISC. MISCELLANEOUS STD. STANDARD NUMBER: 00705100000500 CONT. CONTINUOUS HDW. HARDWARE MTD. MOUNTED STL. STEEL C.J. CONTROL JOINT HDWD. HARDWOOD STRUCT. STRUCTURAL LOT AREA: 0.30 ACRES DET. DETAIL HVAC HEATING / VENTILATION (N) NEW SQ. SQUARE DIM. DIAMETER AIR CONDITIONING NOM. NOMINAL SUSP. SUSPENDED LEGAL DIM. DIMENSION HT. HEIGHT N.I.C. NOT IN CONTRACT DESCRIPTION: NORTHVIEW ESTATES BILK 000 D-00 - LOT 5 DN. DOWN H.P. HIGH POINT NO. NUMBER THK. THICK, THICKNESS D.S. DOWN SPOUT H.C. HOLLOW CORE TYP. TYPICAL SCOPE OF INTERIOR REMODEL DWG. DRAWING H.M. HOLLOW METAL O.C. ON CENTER WORK: BUILDING 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) CODE: SHEETINDEX SHEET NUMBER A0.00 A0.01 02 - ARCHITECTURAL SHEET NAME APPROVED PLANS MUST BE ON JOB SITE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES ALL WORK SUBJECT TO FIELD INSPF[_TI(')N I=C)P COVER ENERGY CODE COMPLIANCE A1.01 SITE PLAN A2.01 DEMO PLAN - MAIN FLOOR A2.02 MAIN FLOOR PLAN A3.01 ELEVATIONS N/E A3.02 ELEVATIONS S/W City Of Edmonds Building Department Work REMODEL Address 1102 12TH AVE N Owner --------------------------------EDDY -------------------------------------- Approved Date ; 6/22/2023 ------------------------------ Building Official 271C7fAcE c Permit Number BLD2023-0648 ",VISIONS PAGES - CHANGES VICINITY MAP SITE LOCATION 00 CD 00 O) J E 1 y V W W rn c� ao ca CM N T N N T" PI Q s N T N O T T 0 N O 00 0) a y C O E W z d a s N 7- N O T T DISCLAIMER DUE TO LIMITED SITE AND PROJECT INFORMATION, ATVAGA ACCEPTS NO LIABILITY FOR THE CONTENT OF THIS DESIGN DRAWINGS OR FOR THE CONSEQUENCES OF ANY ACTIONS TAKEN ON THE BASIS OF THE INFORMATION PROVIDED IN THIS DESIGN DRAWINGS. NOTICE: TEAM GH CHECKED AS DRAWING REVISION DESCRIPTION NO. DATE PERMIT SET 2023-04-28 RECEIVED May 30 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT COVER A0.00 N 0 Alterations Worksheet - 2018 Washington State Energy Code Project Information Contact Information 2301-0004 1102 12th Ave N 1102 12th Ave N, Edmonds, WA 98020 ATVAGA LLC anna@atvaga.com atvaga.com The WSEC requirements for alterations are located in Chapter 5 of the code text. Alterations (remodels) do not need to obtain energy credits from Table R406.3 Additions must meet the requirements for new construction. This includes nonconditioned space being altered to become conditioned space. Will the wall cavities be exposed? Yes v No If yes: Exposed wall cavities must be insulated - 2 X 4 wall studs require R-15 insulation 2 X 6 wall studs require R-21 insulation Will the roof/ceiling framing cavities or attic be exposed? v Yes No If yes: Exposed roof/ceiling assemblies must be insulated - Vaulted ceilings: Insulate to the full depth of the framing member while allowing for the minimum 1" ventilated space Flat ceilings Will the floor framing cavities be exposed? Install R-49 insulation or what the attic space can accommodate based on the roof pitch Yes v No If yes: Exposed floor cavities must be insulated to R-30 Are the windows and/or doors being replaced? Yes No (includes both window or door and frames) If yes: New windows and doors must have an area weighted average U-factor of <_0.30 Will the heating or cooling system be replaced? W Yes No If yes: New equipment must meet current requirements and ducts need to be tested Will the hot water system be altered? Yes v No If yes: New water heating equipment must meet current code requirements Are more than 50% of the light fixtures being changed? Yes v No If yes: 90% of all lamps must be high efficacy (LED or CFL) Property address: Builder/registered design professional name: Builder/reg. design pro. signature: Conditioned floor area: ft' (per building permit) R-Values (R303.1.1) • Ceiling/ Vaulted R-_ - - Floors: Over unconditioned space R------ Attic: Attic R------- Slab -on -grade floor R-_____ Walls: Above grade R- Fully insulated slab? YIN (Circle one) Below, int. R------- Doors: R------- R------- R-_____ Below, ext. R-_ - - U-Value of Windows, Skylights and Doors (R303.1.1.3) Average area weighted LI-value from Glazing Worksheet Average LI- - Fuel Normalization (Tables R406.2) and Energy Credits (Table R406.3) System Type Number (1 to 5) (Select one) Energy Credits selected (1 to 7) ---------- Fuel Normalization Credit ______ + Total Energy Credits _______ = Total Credits_______ Heating, Cooling and Domestic Hot Water System Type (Manufacturer and Model Number) Efficiency Heating Cooling • DHW Drain water heat recovery Onsite Renewable Energy Electric Power System " System type _ _ _ _ _ ____________ _ ___ System design capacity _____ - - kW Rated annual generation kWh/yr Appliances Energy Star? Manufacturer and Model (Circle one) Dish washer Y or N Refrigerator Y or N Washer Y or N Dryer Y or N Vented or unvented? If vented, CEF rating Gas fireplace / heating stove (Section R402.4.2) Fireplace efficiency (FE) Heating or Decorative? (Circle one) HVAC System Duct Leakage Testing (R403.3) Circle one All ductwork and air handler in conditioned space? (See Option 4.2) Y or N All ductwork in unconditioned spaces buried and tested at 3% total leakage, and air Y or N handler in conditioned space? (See Option 4.1.) All ductwork & air handler outside conditioned space insulated to minimum R-8? Y or N Air handler present at duct leakage test? (Total leakage 4% if yes, 3% if no) Y or N HVAC leakage to outside test conducted at final? Y or N Do HVAC duct leakage tests include GPS and time stamp verification? Y or N HVAC system leakage test calculated design target: CFM @ 25 Pa HVAC system leakage test measured results: CFM @ 25 Pa Building Leakage Testing (R402.4.1.2) Dwelling unit leakage test calculated design target: - - - - - _ ACH @ 50 Pa Dwelling unit leakage test, measured results: ACH @ 50 Pa Whole Building Leakage test (R2 corridor only) design target: CFM/sf @ 50 Pa Whole Building Leakage test (R2 corridor only) measured: CFM/sf @ 50 Pa Do building leakage tests include GPS and time stamp verification? Y or N Whole House Ventilation System Measured Flow Rates (M1505.4 IRC-WA) Circle one Are the system controls correctly labeled? Y or N The Whole House Ventilation (WHV) system operation and maintenance (O&M) Y or N instructions were provided to the building owner? Provided to: ----------------------------------------- on --------------------(date) Whole House Ventilation System Type: (Circle one) (1) Whole house exhaust fan, location (2) Balanced HRV/ ERV, location For R2 low-rise, serves more than one unit? Y or N (3) Supply or HRV WHV integral to the air handler. Describe system control sequence of operations or reference to design submittal: -------------------------- Specify run-time: _______ hours per day _______________ CFM WHV calculated design minimum flow rate per plan submittal: WHV measured min flow rate at commissioning: Exhaust ________CFM, Supply - - _CFM Do WHV flow tests include GPS & time stamp verification? Y or N HRV/ERV sensible heat recovery efficiency: Commissioning Notes: Other Mandatory Requirements Circle one AMothermandatory requirements of WSEC-R have been met? Y or N 00 O N 00 G� Q J E J y V W W > N > i O Q� 2 i Cl) N T N T" N T" Q s N T N O T T 0 N O 00 to a y C O E W z d Q s N T" N O T T DISCLAIMER DUE TO LIMITED SITE AND PROJECT INFORMATION, ANAGA ACCEPTS NO LIABILITY FOR THE CONTENT OF THIS DESIGN DRAWINGS OR FOR THE CONSEQUENCES OF ANY ACTIONS TAKEN ON THE BASIS OF THE INFORMATION PROVIDED IN THIS DESIGN DRAWINGS. NOTICE: TEAM GH CHECKED AS DRAWING REVISION DESCRIPTION NO. DATE PERMIT SET 2023-04-28 RECEIVED May 30 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ENERGY CODE COMPLIANCE A0.01 N 0 GENERAL SITE PLAN NOTES SIDE SETBACK PROPERTY LINE PROPERTY LINE 1. Site Plan A1.01 SCALE: 1" = 20'-0" TRUE NORTH PROPERTY LINE 1. LINO ALL EXISTING STRUCTURES INCLUDING TREES SHALL BE RETAINED. 2. UTILITIES SHOWN ON THIS SITE PLAN ARE BASED UPON ABOVE GROUND OBSERVATIONS AND AS -BUILT PLANS WHERE AVAILABLE. ACTUAL LOCATIONS OF UNDERGROUND UTILITIES MAY VARY AND UTILITIES NOT SHOWN ON THIS PLAN MAY EXIST ON THIS SITE. SYMBOL LEGEND r EXISTING HOUSE CONCRETE HATCH ® ASPHALT HATCH ZONING INFORMATION Zoning District: RS-12 SECTION REQUIRED EXISTING PROPOSED COMMENTS LOT AREA 12 000 SF... 13 187 SF 13 187 SF Complies YARDS Front 25 ft. min. 25 ft. 25 ft. Complies Rear 25 ft. min. 25 ft. 25 ft. Complies Side Side YD. 1 10 ft. min. 10 ft. 10 ft. Complies Side YD. 2 10 ft. min. 10 ft. 10 ft. Complies HEIGHT Wall 25 ft max 22.83 ft. 22.83 ft. No Change LOT COVERAGE House 2 526 xx Deck xx xx Garage/Carport xx xx Covered Porches/ Patios xx xx Accessory Structures xx xx Other (explain) xx xx Total Amount Of Lot Coverage 2 526 xx Total Lot SF 13 187 xx Percentage Of Lot Coverage 35% 19% xx No Change IMPERVIOUS COVERAGE Lot Coverage SF Max Allowed Proposed 3752.77 Driveways and Walkways 1 154.79 Other (explain) Total Amount Impervious Surface 4907.56 Total Lot SF 13 187 Percentage Of Impervious Coverage 37.2% 00 O N 00 Q J E 1 y V W W > N > � cC Q � i CM N T N T" N T" FIA a s ♦.0 N T N O T T 0 N O 00 0) a y C O E W z d Q s N T" N O T T DISCLAIMER DUE TO LIMITED SITE AND PROJECT INFORMATION, ATVAGA ACCEPTS NO LIABILITY FOR THE CONTENT OF THIS DESIGN DRAWINGS OR FOR THE CONSEQUENCES OF ANY ACTIONS TAKEN ON THE BASIS OF THE INFORMATION PROVIDED IN THIS DESIGN DRAWINGS. NOTICE: TEAM GH CHECKED AS DRAWING REVISION DESCRIPTION NO. DATE PERMIT SET 2023-04-28 RECEIVED May 30 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SITE PLAN A1.01 N 0 DOOR SCHEDULE DEMO PLAN MARK LEVEL WIDTH HEIGHT HEAD HEIGHT D1 Main Floor 3' - 0" 7' - 0" 4' - 6" D2 Main Floor 3' - 0" 6' - 8" 6' - 8" D3 Main Floor 2'-6" 6'-8" 6'-8" D4 Main Floor 5'-0" 6'-8" 6'-8" D5 Main Floor 2' - 8" 6' - 8" 6' - 8" D6 Main Floor 3' - 3" 6' - 8" 6' - 8" D7 Main Floor 4' - 0" 6' - 8" 6' - 8" D8 Main Floor 2' - 4" 6' - 8" 6' - 8" D9 D10 Main Floor Main Floor 7' - 10" 6' 6' - 8" - 8" 6' - 8" 4'- 11" 6' - 8" D11 Main Floor 2' - 1" 6' - 8" 6' - 8" D12 Main Floor 1' - 6" 6' - 8" 6' - 8" D13 Main Floor 3' - 0" 6' - 8" 6' - 8" Grand total: 18 WINDOW SCHEDULE DEMO P MARK LEVEL SILL WIDTH HEIGHT HEIGHT A Main Floor V - 4" 2' - 4" 1' - 5" B Main Floor 2' - 10" 5' - 0" 0' - 11" C Main Floor 3' - 10" 5' - 10" 0' - 11" D Main Floor 7' - 10" 5' - 10" 0' - 11" E Main Floor 7' - 10" 3' - 10" 3' - 1" F Main Floor 5' - 10" 3' - 10" 3' - 1" G Main Floor 9' - 10" 4' - 10" 2' - 1" H Main Floor 3' - 10" 3- 4" 3' - 4" 1 Main Floor 0' - 10" 3' - 10" 3' - 0" J Main Floor 1' - 10" 4'- 10" 3' - 0" K Main Floor 0' - 11 " 5' - 10" 2' - 7 1 /2" L Main Floor 2'-41/2" 4'-2" 3'-4" M Main Floor 5' - 5" 4'- 2" 3' - 4" N Main Floor 1'- 8" 3' - 4" 3' - 4" O Main Floor 3'-5" 3'-4" 3'-4" P Main Floor 2' - 11" 4'- 10 1/2" 1'- 11" Grand total: 22 NOTE: NO EXTERIOR WORK OR ADDITIONS ARE MADE, ALL WORK IS DONE INSIDE THE EXISTING BUILDING 1. Main Floor Demolition 0 DEMOLITION PLAN LEGEND EXISTING CONSTRUCTION J TO REMAIN E77 EXISTING CONSTRUCTION �( d TO BE DEMOLISHED 00 0 N 00 O� a J E J y V W W > N > ao i M N T N N T" FIA Q s N T N O T T 0 N 0 00 rn a y C O E W z d a s N 7- N O T T DISCLAIMER DUE TO LIMITED SITE AND PROJECT INFORMATION, ATVAGA ACCEPTS NO LIABILITY FOR THE CONTENT OF THIS DESIGN DRAWINGS OR FOR THE CONSEQUENCES OF ANY ACTIONS TAKEN ON THE BASIS OF THE INFORMATION PROVIDED IN THIS DESIGN DRAWINGS. NOTICE: TEAM GH CHECKED AS DRAWING REVISION DESCRIPTION NO. DATE PERMIT SET 2023-04-28 RECEIVED May 30 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A2.01 SCALE: 1/4" = 1'-0" PROJECT NORTH DEMO PLAN - MAIN FLOOR A2.01 FLOOR PLAN LEGEND EXISTING CONSTRUCTION Q NEW CONSTRUCTION FAN SHALL BE 2-SPEED: 3- CFM CONTINIOUS LOW SETTING F AND 50 CFM HIGH SPEED ACTIVATED BY LIGHT SWITH OR OCCUPANCY SENSOR SD SMOKE DETECTOR CO CARBON MONOXIDE DETECTOR W1 WALL TYPE D1 DOOR TYPE 10 WINDOW TYPE GENERAL NOTES FLOOR AREAS SQUARE FOOTAGE -METHOD FOR CALCULATING: ANSI Z765-2003. FINISHED SQUARE FOOTAGE CALCULATIONS FOR THIS HOUSE WERE MADE BASED ON PLAN DIMENSIONS ONLY AND MAY VARY FROM THE FINISHED SQUARE FOOTAGE OF THE HOUSE AS BUILT. FOR DETACHED SINGLE-FAMILY HOUSES, THE FINISHED SQUARE FOOTAGE OF EACH LEVEL IS THE SUM OF FINISHED AREAS ON THAT LEVEL MEASURED AT FLOOR LEVEL TO THE EXTERIOR FINISHED SURFACE OF THE OUTSIDE WALLS. ROOM SIZES INDICATED AT ROOM NAMES ARE DIMENSIONS FOR GENERAL REFERENCE ONLY SEE INTERIOR DETAILS FOR TYPICAL DOOR PLj DOUBLE DOORS CENTERED ON WALL U.N.O. DOOR SCHEDULE HEAD MARK LEVEL WIDTH HEIGHT HEIGHT DOOR D2 Main Floor 3' - 0" 6' - 8" 6' - 8" Single Door D8 Main Floor 2' - 4" 6- 8" 6' - 8" Single Door D9 Main Floor 3' - 10" 6' - 8" 6' - 8" Sliding Door D10 Main Floor 5' - 0" 6' - 8" 6' - 8" Double Door D11 Main Floor 2' - 6" 6' - 8" 6' - 8" Pocket In Doc D12 Main Floor 5' - 2" 6' - 8" 6' - 8" Double Pocke D13 Main Floor 4' - 0" 6' - 8" 6' - 8" Accordion Doi Grand total: 8 Room Schedule Level I Name I Area I Comments Main Floor Master Bedroom 320.29 Main Floor Master Bath. 261.13 Main Floor WC 16.25 Main Floor Hall 275.59 Main Floor Living Room 579.22 Main Floor Kitchen 295.30 Main Floor Powder 30.76 Main Floor Walk in Closet 78.55 Main Floor HVAC 13.65 Main Floor Bathroom 64.49 Main Floor Shower 38.71 Main Floor Bedroom 228.44 Main Floor Utility room 31.60 Main Floor Closet 9.05 Main Floor Hall 118.99 1. Main Floor Proposed A2.02 SCALE: 1/4" = 1'-0" PROJECT NORTH 00 0 N 00 Q i E J y 0 W W > N > Q � i CM N T N T" N T" MIA Q s 11.0 N T C4 O T T 0 N O 00 rn a y c 0 E w z m a s N 7- N O T T DISCLAIMER DUE TO LIMITED SITE AND PROJECT INFORMATION, ATVAGA ACCEPTS NO LIABILITY FOR THE CONTENT OF THIS DESIGN DRAWINGS OR FOR THE CONSEQUENCES OF ANY ACTIONS TAKEN ON THE BASIS OF THE INFORMATION PROVIDED IN THIS DESIGN DRAWINGS. NOTICE: TEAM GH CHECKED AS DRAWING REVISION DESCRIPTION NO. DATE PERMIT SET 2023-04-28 RECEIVED May 30 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT MAIN FLOOR PLAN A2.02 1. Elevation NORTH A3.01 SCALE: 1/4" = 1'-0" 2. Elevation EAST A3.01 SCALE: 1/4" = 1'-0" C? co F_ 0 10 N Maximum Allowed Height 355' - 10 13/16" 7 Roof Top 353' - 9" Roof Plate 349' - 6" Upper Floor 342' - 0" LJ LJ + F �� - Main Floor 7:7777 7777 333' --0" - - — — LAve r a Heghtlof BLDG 330' 1013/16" I I I I I I Maximum Allowed Height Ih 355'-1013/16" r� _ Roof Top 353' - 9" 00 0 N 00 O� Q J E J y V W W > N > � cC Q � i M N T N T" N T" I/I Q s ♦.0 N T N O T T 0 N O 00 a y C O E W z d a' s N N O T T Roof Plate 349' - 6" 0 N Upper Floor J 342' - 0" DISCLAIMER DUE TO LIMITED SITE AND PROJECT INFORMATION, ATVAGA ACCEPTS NO LIABILITY FOR THE CONTENT OF THIS DESIGN DRAWINGS OR FOR THE CONSEQUENCES OF ANY ACTIONS TAKEN ON THE BASIS OF THE INFORMATION PROVIDED IN THIS DESIGN DRAWINGS. NOTICE: 0 o� TEAM GH CHECKED AS DRAWING REVISION Main Floor DESCRIPTION NO. DATE 7 333' - 0" PERMIT SET 2023-04-28 Av_eraa a Hecht of BLDG '330' -1013/16" RECEIVED May 30 2023 Q CITY OF EDMONDS p DEVELOPMENT SERVICES r DEPARTMENT Lower Floor J 323' - 0" ELEVATIONS N/E A3.01 Maximum Allowed Heigh CD 355'-1013/16' 04 O� Roof To a 353' - 9" J E J y V W Roof Plate < w ci > 349' - 6" H ao 2 i M N - T N_ N 7- 0 in N Upper Floor 342' - 0" J L7m ----------------------------------- Floo� 333' - 0" Averqcie Hecht of BLDG 330-1013/16 0 — o _- _ Lower Floor � III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III II 323'-0" �J 1. Elevation SOUTH A3.02 SCALE: 1/4" = 1'-0" MIA Q s N T N O T T Maximum Allowed Hei hg t V 355' -10 13/16" Roof Top � 353' - 9" _Roof Plate 349' - 6�J 0 N O 00 CD a y C O E W z d a s N 7— N O T T DISCLAIMER DUE TO LIMITED SITE AND PROJECT INFORMATION, ATVAGA ACCEPTS NO LIABILITY FOR THE CONTENT OF THIS DESIGN DRAWINGS OR FOR THE CONSEQUENCES OF ANY ACTIONS TAKEN ON THE BASIS OF THE INFORMATION PROVIDED IN THIS DESIGN DRAWINGS. NOTICE: Upper Floor 342' - 0" TEAM GH CHECKED AS Main Floor 333'-0" Ed _1 Ed k 4vera Height of BLDG jk 1 II I III 330'- 10 13/16" '*' 2. Elevation WEST A3.02 SCALE: 1/4" = 1'-0" DRAWING REVISION DESCRIPTION NO. DATE PERMIT SET 2023-04-28 RECEIVED May 30 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ELEVATIONS S/W A3.02