Loading...
APPROVED BLD BLD2023-1491+Architectural_Plan+11.20.2023_9.39.22_PM+3911987GENERAL NOTES PROJECT INFORMATION N PARTIAL AS BUILT MAIN FLOOR PLAN SCALE:1/4" = 1' 0" i I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1piumDing permit Trom I ; TO FIELD -the City of Edmonds. j i INSPECTION FOR I --------------------------------------- ------ -------------------------- ------ ;CODE COMPLIANCE N PARTIALAS BUILT UPPER FLOOR PLAN SCALE:1/4" = 1'-0" THESE DRAWINGS ARE THE PROPERTY OF H21), LLC. ANY REPRODUCTiONS MUST BE AUTHORIZED BY THE ARCHITECT AND MUST BEAR THE NAME OF THE ARCHITECT. COPYRIGHT 2023 5Y H2D, LLC. THESE DRAWINGS ARE PROTECTED BY FEDERAL AND STATE COPYRIGHT LAWS. 1. CODES/REGULATIONS: -CONSTRUCTION TO CONFORM TO THE 2018 INTERNATIONAL RESIDENTIAL CODE (1RC), WASHiNGTON STATE LAWS AND REGULATIONS, CURRENT WASHiNGTON STATE RESIDENTIAL ENERGY CODE AND VARIOUS CODES IMPOSED BY LOCAL AUTHORITIES. -A SEPARATE PERMIT MAY BE REQUIRED FOR PLUMBING, ELECTRICAL, AND/OR MECHANICAL WORK AS APPLiCADLE. -A COPY OF THE APPROVED PERMIT PLANS MUST 5E ON THE JOD SiTE DURING CONSTRUCTION. 2. CONTRACTOR'S RESPONSIBILITY: -PRIOR TO CONSTRUCTION, THE CONTRACTOR 15 TO VERIFY ALL DIMENSIONS AND STRUCTURAL MEMBER SIZES. -DO NOT SCALE CONTRACT DOCUMENTS. -iF ANY DiSCREPANCIES IN THE DRAWINGS OR FROM THE CODES ARE NOTED, ARCHITECT 15 TO DE NOTIFIED IMMEDIATELY. -ALL CHANGES MADE DY THE CONTRACTOR SHALL 5E SUDMiTTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO CONSTRUCTION. -THE ARCHITECT SHALL NOT HAVE CONTROL OR CHARGE OF, AND SHALL NOT DE RE5PONSiD1_E FOR CONSTRUCTION MEANS AND METHODS, SAFETY PRECAUTIONS, ACTS OR OMISSIONS OR PERFORMANCE OF THE CONTRACTOR. -CONTRACTOR SHALL DE RESPONSiDLE FOR THE PERFORMANCE AND WEATHERPROOFING OF THE ENTIRE DUiLPiNG, iTS COMPONENT EQUIPMENT, AND PARTS. -ALL STRUCTURAL SYSTEMS SUCH AS WOOD TRUSSES WHICH ARE TO DE COMPOSED OF COMPONENTS TO DE FIELD ERECTED SHALL DE SUPERVISED DY THE SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE, AND ERECTION IN ACCORDANCE WiTH INSTRUCTIONS PREPARED DY THE SUPPLER. -ALL WORK MUST FOLLOW CURRENT RRP RULES AND REQUIREMENTS AS DEFINED 5Y THE EPA AND THE STATE OF WASHiNGTON. -ALL WASTE AND REFUSE CAUSED iN CONNECTION WiTH THE WORK SHALL 5E REMOVED FROM THE PREMISES AND DISPOSED OF BY THE CONTRACTOR. THE PREMISES SHALL DE LEFT CLEAR AND CLEAN TO THE SATISFACTION OF THE OWNER. -CONTRACTOR SHALL DESIGN AND INSTALL SHORING AS REQUIRED TO PERFORM WORK. ENGINEERING, CONSTRUCTION AND SAFETY OF THE SHORING SHALL DE THE RESPONSi131LiTY OF THE CONTRACTOR. -FOR ALL NEW CONSTRUCTION OR ADDITIONS DESIGNED WiTHiN 1'-0" OF THE HEIGHT LiMiT, THE CONTRACTOR SHALL DE RESPONSIBLE FOR COORDINATING WiTH THE SURVEYOR TO VERIFY THE ELEVATION OF THE STRUCTURE AS iT 15 SEiNG 5UiLT TO VERIFY ANY ELEVATION PISCRPANCiES THROUGHOUT CONSTRUCTION. ELEVATIONS SHOULD DE VERIFIED FOR EACH FLOOR LEVEL PRIOR TO PROCEEDING WiTH THE NEXT FLOOR OF FRAMING: TOP OF FOUNDATION, TOP OF SUDFLOOR, TOP PLATE AND RIDGE ELEVATIONS SHOULD DE VERIFIED DURING CONSTRUCTION. CONSULT ARCHITECT FOR CLARIFICATION PRIOR TO CONSTRUCTION. 3. SOILS: -FOUNDATION DESIGN 15 DASED ON AN ASSUMED AVERAGE SOiL DEARiNG OF 2,000 PSF OR PER GEOTECHNiCAL REPORT. ALL FOOTINGS SHALL DE CAST ON UNDI5TURBED FiRM NATURAL 501L OR COMPACTED SOIL OF 2,000 PSF DEARiNG CAPACITY AT LEAST 1'-6" DELOW LOWEST ADJACENT GRADE, AND FREE OF ORGANIC MATERIALS. FOOTING EXCAVATION SHALL DE FREE OF L005E SOiLS, DESRiS, AND FREE WATER AT ALL TIMES. TH15 OFFICE TAKES NO RESPONSiDiL1TY iN VERIFYING THE ACCURACY OF ENGINEERING DATA SUPPLIED DY OTHERS. 4. ATTIC REQUIREMENTS: -APPLY ROOFING iN ACCORDANCE WiTH iRC CHAPTER 9. PROVIDE ATTiC VENTILATION AS INDICATED ON DRAWINGS AND AS OUTLINED 1N iRC SEC R806. -THE NET FREE VENTILATING AREA SHALL DE NOT LE55 THAN 1/150 OF THE AREA OF THE SPACE VENTILATED, EXCEPT THAT THE AREA MAY DE 1/300 PROVIDED AT LEAST 50 PERCENT OF THE REQUIRED VENTILATING AREA 15 PROVIDED 5Y VENTILATION LOCATED iN THE UPPER PORTION OF THE SPACE TO DE VENTILATED AT LEAST 3 FEET ABOVE EAVE OF CORNICE VENTS WiTH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. (1RC SEC R806). -ATTIC ACCESS: MINIMUM 22" x 30" WiTH MiNiMUM 30" HEADROOM, UNOBSTRUCTED, READILY ACCESSi13LE OPENING. iRC SEC R807. ACCESS DOORS SHALL DE WEATHERSTRiPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES. -iN ROOMS NOT PROVIDED WiTH AN OPERABLE WINDOW OF 1.5 5Q. FT. OR GREATER, A MECHANICAL VENTILATION SYSTEM CAPABLE OF PROVIDING 5 AIR CHANGES PER HOUR SHALL BE PROVIDED. -VENT DRYER, BATH FANS, AND RANGES/OVENS TO THE OUTSIDE. 5. VENTILATION: -VENT FANS SHALL TERMINATE AT THE EXTERIOR OF THE BUILDING PER iRC SECTION M1502.3 AND 1MC SECTION 501.3. -INSULATE ALL DUCTS OUTSIDE OF CONDITIONED SPACE PER WA STATE ENERGY CODE. -KITCHEN RANGE HOODS: RANGE HOODS CAPABLE OF EXHAUSTING MORE THAN 400 CFM REQUIRE MAKE-UP AiR PER iRC M1503.6. 6. GLAZING: -TO 5E iN COMPLIANCE WiTH 1RC SEC R308 AND WASHiNGTON STATE SAFETY GLASS LAW, EXCEPTIONS ARE AS OUTLINED iN iRC SEC R308. -GLAZING 1N LOCATIONS 5UBJECT TO HUMAN IMPACT SUCH AS GLA551N DOORS, GLAZING WiTHiN 24" ON EITHER SiDE OF A DOOR OPENING, GLAZING CL05ER THAN 18" TO A FLOOR, SHOWER DOORS AND TUB ENCLOSURES SHALL DE WiRE REINFORCED, TEMPERED GLASS, LAMINATED SAFETY GLA55 OR SHATTER RESISTANT PLASTIC. -SLIDING GLASS DOORS TO DE SAFETY GLAZING, LAMINATED OR TEMPERED GLASS. -SHOWER ENCLOSURES SHALL DE APPROVED WiRE REINFORCED, TEMPERED OR. LAMINATED SAFETY GLASS OR SHATTER RESISTANT PLASTIC. -GLAZING WiTHiN 18" OF FLOOR AND GREATER THAN 18" 1N LEAST DIMENSION SHALL COMPLY WiTH IMPACT LOADS. SEE PLANS. -ALL EXTERIOR WALL GLAZING SHALL DE DOUBLE GLAZED, UNLESS NOTED OTHERWISE, AND COMPLY WiTH STATE OF WASHiNGTON ENERGY CODE. -EGRESS iN EVERY SLEEPING ROOM SHALL HAVE A MiNiMUM NET CLEAR OPENING OF 5.7 5Q. FT. THE MiNiMUM NET CLEAR OPENING HEIGHT DIMENSION SHALL DE 24", MINIMUM NET CLEAR OPENING WIDTH OF 20" AND A FINISHED SiLL HEIGHT NOT MORE THAN 44" A13OVE THE FLOOR. iRC SEC R310. 7. ENERGY: -ALL MATERIALS, WORKMANSHIP AND CONSTRUCTION SHALL CONFORM TO iRC REQUIREMENTS AND THE WASHiNGTON STATE ENERGY CODE, LATEST EDITION. VERIFY ALL CONDITIONS BEFORE PROCEEDING WiTH WORK. -APPLICATION AND INSTALLATIONS OF INSULATION AND VAPOR DARRiERS SHALL COMPLY WiTH STATE OF WASHiNGTON THERMAL INSULATION STANDARDS. -BUILDING AiR LEAKAGE TESTING, PER SEC 402.4.15 REQUIRED PRIOR TO FINAL INSPECTION. THE TEST RESULTS SHALL DE POSTED ON THE RESIDENTIAL ENERGY COMPLIANCE CERTIFICATE. -EACH DWELLING UNiT 15 TO HAVE ONE PROGRAMMADLE THERMOSTAT FOR REGULATION OF TEMPERATURE PER SEC 403.1. -A SIGNED AFFADAViT DOCUMENTING THE DUCT LEAKAGE TEST RESULTS SHALL BE PROVIDED TO THE BUILDING INSPECTOR PRIOR TO AN APPROVED FINAL INSPECTION. -DUCT LEAKAGE TEST RESULTS SHALL 5E PROVIDED TO THE BUiLPING INSPECTOR AND HOMEOWNER PRIOR TO AN APPROVED FINAL INSPECTION. -MiNiMUM 90% OF PERMANENTLY INSTALLED LAMPS iN LIGHTING FIXTURES SHALL DE HiGH EFFICACY LAMPS PER SEC 404.1. -WHERE THE PRIMARY HEATING SYSTEM 15 A FORCED-AiR FURNACE, AT LEAST ONE THERMOSTAT PER DWELLING UNiT SHALL DE CAPADLE OF CONTROLLING THE HEATING AND COOLING SYSTEM ON A DAiLY SCHEDULE TO MAINTAIN DIFFERENT TEMPERATURE SET POINTS AT DIFFERENT TIMES OF THE DAY. THE THERMOSTAT SHALL ALLOW FOR, AT A MiNiMUM, A 5-2 PROGRAMMADLE SCHEDULE (WEEKDAYS/WEEKENDS) AND DE CAPADLE OF PROVIDING AT LEAST TWO PROGRAMMADLE SETBACKS PER DAY. 8.STAIRS: -MiNiMUM HEADROOM 6-8"; MiNiMUM TREAD 10"; MAXIMUM RISER 7 3/4" -HANDRAIL: REQUIRED AT ALL STAIRS WiTH MORE THAN 4 RISERS PER 1RC 311.7.8. MINIMUM 34" AND MAXIMUM 38" ADOVE TREAD NOSING. OPEN SIDES OF STAIRS MORE THAN 30" ABOVE ADJACENT FLOOR SHALL HAVE HANDRAi1_5 AND GUARDRAILS. HANDRAIL TO DE 1 1/4"-2" CROSS SECTIONAL DIMENSION AND 1 1/2" AWAY FROM WALL. -GUARDRAIL: SHALL 5E MiN 36" iN HEIGHT WHERE ADJACENT SURFACE OR GRADE 15 30" OR. MORE 5ELOW. RAILINGS SHALL BE SPACED TO NOT ALLOW THE PA55AGE OF A 4-3/8" SPHERE PER iRC 312.1. -INSTALL FiRE DLOCKiNG AT MiD-STRINGER SPAN AND AT WALL ALIGN STRINGER. -COVER WALLS AND SOFFITS OF U5ADLE SPACE UNDER STAIR WiTH 5/8" TYPE "X" GYPSUM WALLBOARD. 9. INSULATION: -INSULATION TO MEET THE CURRENT WASHINGTON STATE ENERGY CODE REQ'T5 FOR TABLE R402.1.1, TABLE R402.1.3 AND SECTION R402. REFER TO PRESCRIPTIVE TABLE ON SHEET 01. -EXISTING WALL AND FLOOR CAVITIES EXPOSED DURING CONSTRUCTION FOUND UNiNSULATED, OR WiTH DAMAGED INSULATION (DISCOLORED, WET, DAMAGED, OR DETERIORATED) SHALL BE FILLED WiTH R-151NSULATiON AT 2X4 FRAMING AND WiTH R-21 INSULATION AT 2X6 FRAMING. REF SEC R503.1.1-EXCEPTION 2.. -WALLS TO DE iN5ULATED WiTH MiNiMUM R-21 INSULATION. DELOW GRADE WALLS TO DE INSULATED WiTH MiNiMUM R-21 INSULATION, ALLOW FOR THERMAL BREAK BETWEEN FLOOR SLAU AND BASEMENT WALL UNLESS NOTED OTHERWISE. -ROOF AND CEILING INSULATED WiTH R-49 BLOWN-iN AT FLAT CEILINGS AND R-38 H.D. SATT AT VAULTED AREAS UNLESS NOTED OTHERWISE. -ROOF: ALLOW FOR A MiNiMUM 1" CLEAR BETWEEN TOP OF INSULATION AND DOTTOM OF SHEATHING FOR VENTING UNLESS NOTED OTHERWISE. -VENTING 15 REQUIRED iN EACH JOiST SPACE. WHERE CONTINUOUS VENTING WiTH A JOIST SPACE 15 iNTERRUPTED 5Y A HEADER (FOR EXAMPLE AT A SKYLIGHT OR HiP), PROVIDE (2)1 1/2" VENTING HOLES AT THE TOP OF THE RAFTER AT THE HEADER TO ALLOW FOR CONTINUOUS THRU-VENTING INTO THE NEXT J015T SPACE UNLESS NOTED OTHERWISE. -FLOORS: INSULATED WiTH R-30 SATT INSULATION OVER UNHEATED SPACE UNLESS NOTED OTHERWISE. -SLAD-ON-GRADE: PROVIDE EXTRUDED RIGiD CLOSED CELL R-10 INSULATION. INSULATION TO PROVIDE THERMAL BREAK DETWEEN SLAD AND FOOTING AND RUN FROM THE TOP OF THE SLAB TO THE BOTTOM OF THE FOOTING. INSULATION MAY 5E INTERRUPTED FOR 6" EVERY 2'-0" TO ALLOW FOR DOWELING TO TiE SLAD AND FOOTING TOGETHER. UNLE55 NOTED OTHERWISE. 10. GARAGE SEPARATION: -REQUIRES 1/2" GWB ON THE GARAGE SiPE. 5/8" TYPE'X' GWD WHERE THERE 15 LiViNG SPACE ABOVE. SUPPORTING COLUMNS, WALLS AND REAMS USE 1/2" GWD PER 1RC R302.6 -OPENINGS INTO A GARAGE: OPENINGS INTO A GARAGE SHALL HAVE A SOLID WOOD OR HONEYCOMD-CORE STEEL DOOR NOT LESS THAN 1-3/8" THICK, OR 20-MINUTE FiRE RATING. DOORS SHALL BE EQUIPPED WiTH A SELF -CLOSING DEVICE PER iRC R302.5.1. 11. VAPOR BARRIERS: -AN APPROVED VAPOR BARRiER SHALL DE INSTALLED AT EXTERIOR WALLS AND AT ALL ROOF DECKS, DELOW ENCLOSED JOIST SPACES WHERE CEILING FINISHES ARE DIRECTLY INSTALLED TO JOISTS, AND ANY OTHER WALL OR CEILING SURFACES WHICH RECEIVE INSULATION. THiS VAPOR BARRiER MAY DE A COMPONENT OF THE INSULATION MATERIAL. APPLICATION AND INSTALLATIONS OF INSULATION AND VAPOR BARRIERS SHALL COMPLY WiTH STATE OF WASHiNGTON THERMAL INSULATION STANDARDS. 12. FIRE SAFETY: -SMOKE ALAKM5/DETECTORS (S.D.): SMOKE ALARMS/DETECTORS SHALL DE INSTALLED iN ALL SLEEPING ROOMS, iN THE AREA OUTSIDE THE SLEEPING ROOM AND iN OTHER LOCATIONS PER iRC R314. POWER SOURCE AND INTERCONNECTION PER 1RC. -CARBON MONOXIDE DETECTORS (C.M.D.): SHALL HAVE AN APPROVED CAR50N MONOXIDE ALARM INSTALLED OUTSIDE OF EACH SLEEPING AREA iN DWELLING UNITS AND IN EACH LEVEL iN ACCORDANCE WiTH THE MANUFACTURER'S REQUIREMENTS PER 1RC315. SINGLE STATION CARBON MONOXIDE ALARMS SHALL BE LISTED AS COMPLYING WiTH UL2034 AND SHALL DE INSTALLED 1N ACCORDANCE WiTH THiS CODE, NFPA 720-2012 AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. -CARBON MONOXIDE DETECTION SYSTEMS PER 1RC 315.2 THAT INCLUDE CARBON MONOXIDE DETECTORS AND AUDIBLE NOTIFICATION APPLIANCES, INSTALLED AND MAINTAINED 1N ACCORDANCE WiTH THiS SECTION FOR CARBON MONOXIDE ALARMS AND NFPA 720-2012, SHALL 5E PERMITTED. THE CARBON MONOXIDE DETECTORS SHALL BE LISTED AS COMPLYING WiTH UL 2075. WHERE A HOUSEHOLD CARBON MONOXIDE DETECTION SYSTEM 15 INSTALLED, iT SHALL BECOME A PERMANENT FIXTURE OF THE OCCUPANCY. 13. CERTIFICATE & TESTING - A PERMANENT CERTIFICATE SHALL BE COMPLETED AND POSTED ON OR WiTHiN THREE FEET OF THE ELECTRICAL PISTRiDUT10N PANEL BY THE BUILDER OR REGISTERED DESIGN PROFESSIONAL. THE CERTIFICATE SHALL BE COMPLETED BY THE BUILDER OR REGISTERED DESIGN PROFESSIONAL AND SHALL NOT COVER OR OBSTRUCT THE V15113iLiTY OF THE CiRCUiT DIRECTORY LABEL, SERVICE DISCONNECT LABEL, OR. OTHER REQUIRED LABELS. THE CERTIFICATE SHALL LiST THE PREDOMINANT R-VALUES OF INSULATION INSTALLED iN OR ON CEILING/ROOF WALLS, FOUNDATION (SLAB, BELOW -GRADE WALL, AND/OR FLOOR) AND DUCTS OUTSIDE CONDITIONED SPACES; U- FACTORS FOR FENESTRATION AND THE RESULTS FROM ANY REQUIRED DUCT SYSTEM AND BUILDING ENVELOPE AiR LEAKAGE TESTING DONE ON THE BUILDING. WHERE THERE 15 MORE THAN ONE VALUE FOR EACH COMPONENT, THE CERTIFICATE SHALL LiST THE VALUE COVERING THE LARGEST AREA. THE CERTRiF1CATE SHALL LiST THE TYPES OF EFFICIENCIES OF HEATING, COOLING, AND SERVICE WATER HEATING EQUIPMENT. - THE BUILDING OR DWELLING UNiT SHALL BE TESTED AND VERIFIED AS HAVING AN AiR LEAKAGE RATE OF NOT EXCEEDING 5 AiR CHANGES PER HOUR. TESTING SHALL DE CONDUCTED WiTH A BLOWER DOOR AT A PRESSURE OF 0.2 INCHES W.G. (50 PASCALS). WHERE REQUIRED BY THE CODE OFFICIAL, TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD PARTY. A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL BE SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED TO THE CODE OFFICIAL. TESTING SHALL DE PERFORMED AT ANY TiME AFTER CREATION OF ALL PENETRATIONS OF THE DUiLPING THERMAL ENVELOPE. 14. LIGHTING EQUIPMENT - NOT LE55 THAN 90 PERCENT OF LAMPS iN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HiGH-EFFICACY LAMPS -F City Of Edmonds Building Department Work REMODEL Address 23910 74TH AVE W --------------------------------------------------------- Owner - -------------------------------------------------------------- BRYANT Approved Date ------------------------------------- 12/05/2023 Building Official D W. Permit Number BLD2023-1491 REVISIONS DATE - PAGES - CHANGES REV1 REV2 REV3 REV4 REV5 PROJECT OWNER: ANTONiA AND DANiEL BRYANT 23910 74TH AVE W EDMONDS WA 98026 PROJECT ARCHITECT: HEiDi HELGE50N PROJECT DESIGNER: SARAH THOMPSON H2D ARCHITECTURE + DESIGN 23020 EDMONDS WAY, #113 EDMONDS, WA 96020 206-542-3734 STRUCTURAL ENGINEER: DIRK ROGSTAD CG ENGINEERS 250 4TH AVE 5, SUITE 200 EDMONDS, WA, 98020 425-778-8500 PROJECT DESCRIPTION: KITCHEN AND PRIMARY 5ATHROOM REMODEL, INTERIOR ONLY PROJECT ADDRESS: 23910 74TH AVE W TAX LOT NUMBER: 488800600601 LEGAL DESCRIPTION: LAKE BALLiNGER LAND CO SUDPIV 1 BLK 006 D-01-N 1/2 LOT 6 LESS E 5FT TO CiTY EDM REC VOL 1832 PG 1591 AF NO 8403060200 LAND USE CODE COMPLIANCE STATISTICS ZONE: F\S-g REQ'D SETBACKS: STREET SETBACK: 25' REAR SETBACK: 15' SiDE SETBACK: 7.5' *NO CHANGE PROPOSED PARKING: 2 EXISTING PARKING SPACES TO REMAIN SUiLPING HEIGHT DU1LPING HEIGHT LIMIT = 25' INFORMATION: **NO CHANGE PROPOSED *REFER TO 02 SHEET FOR ADDITIONAL LAND USE CODE COMPLIANCE STATISTICS ENERGY CREDIT INFORMATION NOT APPLiCADLE FOR INTERIOR REMODEL - NO NEW CONDITIONED SPACE PROPOSED PRESCRIPTIVE REQUIREMENTS- ALL CLIMATE ZONES LOCATION R-VALUE U-FACTOR FENESTRATION U-FACTOR N/A 0.30 SKYLIGHT U-FACTOR N/A 0.50 GLAZED FENESTRATION SHGC N/A N/A CEILING 49 0.026 WOOD FRAME WALL 21 iNT 0.056 MASS WALL R-VALUE 21/21 0.056 FLOOR 30 0.029 BELOW GRADE WALL 10/15/21 iNT + 5T13 0.042 SLAB R-VALUE AND DEPTH 10, 2 FT N/A SHEET INDEX 01 PROJECT INFORMATION, VICINITY MAP, GENERAL NOTES, AS -BUILT PLANS 02 SiTE PLAN, LAND USE CODE STATISTICS A1.0 PARTIAL MAiN FLOOR DEMOLITION PLAN A1.1 PARTIAL MAiN FLOOR PLAN, WINDOW AND DOOR SCHEDULES A1.2 PARTIAL UPPER FLOOR PLAN A1.3 PARTIAL ROOF PLAN A2.0 EXTERIOR ELEVATION, PARTIAL 13UiLPING SECTION, PARTIAL TYP WALL SECTION A5.0 TYP. DETAILS 51.1 STRUCTURAL NOTES, ROOF FRAMING PLAN, AND DETAILS 236TH T 2 OTH ST W i /iiiiiii./i.�ijj ���� SiTE `� _ ii.iii%iii.iii% / 2 0 H ST SW ; VICINITY MAP (NTS N W U Z (N W Q w C:) � v J W U) o Z Z -r-- CY M O G CN ry W 9716 REGISTERED ARCHITECT /Pl.� HEIDI MICHELLE HELGESON STATE OF WASHINGTON H 2 D ARCH ITECT U R E D E S+ I G N 23020 EDMONDS WAY, #113 EDMONDS, WA 98020 P.206.542.3734 www.h2darchitects.com DATE: 11 /20/2023 PERMIT SET PROJECT INFORMATION, VICINITY MAP, GENERAL NOTES, AS -BUILT PLANS RECEIVED Nov 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 01 LAND USE CODE COMPLIANCE STATISTICS ZONE: R S-0 PL = 195.66'+/- ---- wo-----------------.-.-.-.-.-.----.-.-.-.-.-.----.-.-----------.-.-.-.-.-.-.-.-.-.-.-.-------, � fv I _ � \L\XV r_ni.�i nvv v Niv t_rrii iv REAR I REMAiN I YARD M M M IM M I I I ESTIMATED EXISTING I WATER LiNE LOCATION, EXISTING CONFIRM iN FIELD STRUCTURE o EX TO REMAIN Nlz � I <Q I I I w I I � I I � I I I I EXISTING WALK TO I REMAIN I � I I EX ENTRY I I I I 23910 74TH "E W o I EDMONDS, WA 95026 INTERIOR REMODEL OF EX15TiNG RESIDENCE a I I 25'-0" REQ'D FRONT YARD I � I I � I I i I SS , I ESTIMATED EXISTING S 5EWER LiNE LOCATION, I S � CONFIRM iN FIELD EX PATIO TO � � REMAIN SS I SS , I EX POOL TO I SS REMAIN S S I \SSA i I I • I EX EWALK AND I STEPS TO i I REMAIN I I � PL = 185.99'+/- SITE PLAN SCALE: V =10' SiTE PLAN NOTES: 1. ALL UTILITIES TO 6E LOCATED AND VERIFIED PRIOR TO ANY GROUND PISTURDANCE. **NO GROUND D15TURDANCE PROP05ED iN PROJECT SCOPE.** EXISTING LOT AREA: 29349 5F+/- LOT COVERAGE: ALLOWED LOT COVERAGE: 29349 5F X 35% = 10272.2 5F+/- EX15TING STRUCTURES TO REMAIN *NO NEW LOT COVERAGE OR NEW IMPERVIOUS SURFACES PROPOSED **NO GROUND P15TURDANCE PROP05ED I SS I I I N w U Z co W 0 w o rn — U) Q Q Lu _ U) o Z Z CM O 2i N 0 W N� L.L m 9716 REGISTERED ARCHITECT GST DIMICHELLE HELGESON ATE OF WASHINGTON H 2 D A R C H I T E C T U R E D E S I G N 23020 EDMONDS WAY, #113 EDMONDS, WA 98020 P. 206 . 542 . 3 7 34 www.h2darchitects.com DATE: 11 /20/2023 PERMIT SET SITE PLAN, LAND USE CODE STATISTICS RECEIVED Nov 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 02 DEMO TiLE AND PLUMBING FIXTURES TO BE REPLACE DEMO FLOOR TiLE AND BASE TO BE REPLACED DEMO FINISHES AND FIXTURES 9 EXISTING BATHROOM t i �--------- III II All I II I I II DEMO EX EXHAUST VENT DUCTING DEMO TILE 9 F.P. SURROUND, PREP FOR REPLACEMENT III EXISTING BEAM ABOVE TO III REMAIN �I DEMO EXISTING BUILT-INS III I II DEMO EXISTING WINDOW, PREP FOR WALL iNFiLL DEMO WINDOW & EXISTING SKYWALL, PREP FOR REPLACEMENT & ROOF iNFiLL PARTIAL MAIN FLOOR DEMOLITION PLAN SCALE:1/4" = T-O" 0 EXISTING WALLS r - 'i DEMO WALLS L _ J NOTES: 1. VERIFY SALVAGE ITEMS WiTH OWNER PRIOR TO DEMOLITION. 2. ALL SHORING TO BE THE RESPONS1131LiTY OF THE BUILDER. CONTACT THE STRUCTURAL ENGINEER WiTH QUESTIONS. EXISTING FLOOR LiNE ABOVE TO KEMAiN 'o- \� to � \ -�"- V-17 \ IF -111 1 o ;III 1 L -j II - DEMO FINISHES II AND FIXTURES 9 � III EXISTING II II KITCHEN a , , EXISTING FIREPLACE AND \\ FINISHES TO REMAIN - \ I \ \\ \ EXISTING BEAM \ \\ ABOVE TO \\ REMAIN \\ I DEMO HARDWOOD AT LiViNG AND PINiNG, PREP FOR REPLACEMENT, REFER TO PLAN WIDEN OPENING PER PLAN ir or ON � - DEMO WINDOW & EXiSTiNG SKYWALL, PREP FOR REPLACEMENT & ROOF iNFiLL PARTIAL UPPER FLOOR DEMOLITION SCALE:1/4" = P-0" 0 EXISTING WALLS r - -1 DEMO WALLS L _ J NOTES: 1. VERIFY SALVAGE ITEMS WiTH OWNER PRIOR TO DEMOLITION. 2. ALL SHORING TO BE THE RESPONSIBILITY OF THE BUILDER. CONTACT THE STRUCTURAL ENGINEER WiTH QUESTIONS. N PLAN W CU Z (c) (N W W C) rn W U) ti o o z Z Q � rn M O N � ry m 9716 REGISTERED ARCHITECT xlw Gpl. HEIDI MICHELLE HELGESON STATE OF WASHINGTON H 2 D A R C H IT E C T U R E D E S I G N 23020 EDMONDS WAY, #113 EDMONDS, WA 98020 P.206.542.3734 www.h2darchitects.com DATE: 11/20/2023 PERMIT SET MAIN FLOOR DEMOLITION PLAN RECEIVED Nov 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A1.0 INSTALL 110 CFM BATH FAN, VENT TO OUTSIDE TYP EXISTING WINDOWS P. BEDROOM NEW CARPET EXISTING EXISTING WINDOWS WINDOWS & DOOR P. CLOSET NEW CARPET EX P. BATH 71 u� NEW TiLE EX BEAM ❑F EX ABOVE P. P. ENTRY NEW CARPET EX S.D tall ILL '-' '� 7- S&P (s) P. CLO. � - CARPET = NEWQ 81-0" '1 J �9 3/4" HiGH WALL 01 DEMO CLERESTO Y WINDOWS, iNFiLL VVALL TYP (SEE PET. 2/ 2.0 2 A2.0 PARTIAL MAIN FLOOR PLAN I MAKE i UP LINEN/ STOR. WINDOW SCHEDULE ID ROUGH OPENING *SEE NOTE 1 ROUGH HEAD FROM SUBFLR. TYPE OPER AREA (SF) NOTES U-VAL WIDTH HEIGHT MAiN FLOOR 01 6'-1" 2'-10" 74' A I P 20.20 1 VER FiT iN EX. R.O. 0.30 02 10'-0" 4'-0" 74' A P 45.00 VER FIT ]N EX. R.O. 0.30 TOTAL EXTERIOR WiNDOW AREA: 65.20 NFRC 100 LABELED AND CERTIFIED BY THE MANUFACTURER MANUFACTURER: VERIFY TO MATCH EXISTING SERIES: VERIFY TO MATCH EXISTING GENERAL WiNPOW NOTES: 1. ADD 1/2" TO THE BOTTOM OF THE ROUGH OPENING, UNLESS NOTED OTHERWISE FOR INSTALLATION OF BEVEL SiLL 1. VERIFY ROUGH OPENING SIZES WiTH SELECTED MANUFACTURER REQUIREMENTS 2. SEE ELEVATIONS FOR CONFIGURATION 3. VERIFY ALL SIZES AND ROUGH OPENINGS PRIOR TO CONSTRUCTION 4. VERIFY EXISTING ROUGH OPENINGS WHERE WINDOWS ARE BEING REPLACED iN THE EXISTING OPENINGS PRIOR TO ORDERING THE WINDOWS 5. CONTACT ARCHITECT IMMEDIATELY WiTH QUESTIONS 6. TRANSLUCENT GLASS TO BE SATIN ETCH. PROVIDE GLASS SAMPLE TO OWNER/ARCH FOR APPROVAL PRIOR TO ORDERING 7. ALL WINDOWS IN SHOWERS TO BE VINYL, FIBERGLASS OR RATED FOR USE iN WET LOCATION. VERIFY CONFIGURATION OF SHOWER WINDOWS WiTH OWNER PRIOR TO ORDERING. WiNPOW TYPE: NOTE: 1. REFER TO SCHEDULE FOR ALL DIMENSIONS UNLE55 NOTED OTHERWISE. 2. REFER TO ADDITIONAL GENERAL WiNDOW NOTES ABOVE UNLESS NOTED OTHERWISE. LN Y �vr POWDER (EX) TiLE EXISTING EX WINDOWS ENTRY (EX) WOOD \ EX FLOOR \ UP `\\ LiNE A13OVE�� /-- POT FILLER HALL EX (EX) WOOD MAiL ZONE/ CHARGING - - - -STATION *SEX BEAM i i i i EX F.P. i (NEW TiLE SURROUND & HEARTH) SITTING (EX) WOOD /4/-COFFfE 3 BAR �. KZK a I KITCHEN I (EX) WOOD �\ II r------- , I 1 30" STM: r----- OVEN ' 36" I ; RNGE = -- ---; 1'-1" r l l ]ISLAND ; ;OVEN I Y I ir ----- I — --J--� ----- 3 6--- ���---- X 4'-0" I I I _ z CV II DISHES i ----- i + 0 4'-0" I SEATING I I i BEV 24" TYP. ; REF! ��/ ;� DW EXISTING WINDOWS &DOOR 45" SINK I X I II'' �E�l XISTiNG RO OVERHANG, TYP. 02 DEMO SKYWALL AND iNF]LL NEW ROOF FRAMING & — ROOFING TO MATCH EXISTING GLA55 HOLDER 1 iN CAB'T DOOR A2.0 PARTIAL A A2.0 SCALE:1/4" = 1'-0" 0 EXISTING WALLS ® NEW WALLS NOTES: 1. ALL DIMENSIONS ARE GIVEN TO THE FACE OF STUD UNO. 2. ALL DOOR AND WiNDOW DIMENSIONS ON THiS PLAN ARE TO CENTERLINE OF ROUGH OPENING U.N.O.; REFER TO SCHEDULES & MANUFACTURER INSTALLATION REQUIREMENTS FOR ROUGH OPENING SiZE. 3. SEE ATTACHED WSEC FORMS AND ENERGY REQUIREMENTS ON 01 FOR ENERGY CODE COMPLIANCE INFORMATION. 4. INSTALL SMOKE DETECTORS (S.D.) AT LOCATIONS SHOWN. HARDWIRE AND INTERCONNECT DETECTORS TO POWER SUPPLY AND PROVIDE BATTERY BACKUP AS REQUIRED. 5. INSTALL CARBON MONOXIDE ALARMS (C.M.D.) OUTSIDE EACH SEPARATE SLEEPING AREA iN THE IMMEDIATE VICINITY OF THE BEDROOMS. THE ALARM SHALL BE LISTED AS COMPLYING WiTH UL 2034 AND SHALL BE INSTALLED iN ACCORDANCE WiTH iRC R315.3 AND THE MANUFACTURER'S iNSTALLATiON INSTRUCTIONS. HARDWIRE AND INTERCONNECT DETECTORS TO POWER SUPPLY AND PROVIDE BATTERY BACKUP AS REQUIRED. 6. SMOKE DETECTORS (S.D.) AND CARBON MONOXIDE ALARMS (C.M.D.) TO BE INSTALLED 3'-0" MiNiMUM FROM BATHROOM DOORS. 7. ALL GAS FIREPLACE HEATERS RATED TO ANSI Z21.88 SHALL BE LISTED AND LABELED WiTH A FIREPLACE EFFICIENCY (FE) RATING OF 50 PERCENT OR GREATER iN ACCORDANCE WiTH CSA P.4.1. VENTED GAS FIREPLACES (DECORATIVE APPLIANCES) CERTIFIED TO ANSI Z21.50 SHALL BE LISTED AND LABELED, INCLUDING THEIR FE RATINGS, IN ACCORDANCE WiTH CSA P.4.1. CLO BEDROOM (EX) i EX FLOOR LINE ABOVE EX BEAM ABOVE LIVING (N) WOOD OPEN SHELVES POT FILLER INSTALL RANGE HOOD; HOODSbVER J�400 CFM REQUIRE MAKE UP A]R. MAKE UP AiR TO BE iNTERLOCKED� WiTH FAN OPERATION AT A RATE APPROXIMATELY EQUAL TO THE 0 EXHAUST AiR RATE PER M1506.3. _ W � w w Ito DINING (N) WOOD NEW WD FLOORING TO y MATCH EX 9 KiTCHEN OPEN SHELVES & UPPER CAB'S (BOTH SIDES OF SiNK) J N A OPERABILITY KEY A = AWNING C = CASEMENT H.S. = HORIZONTAL SLIDER P = PICTURE S.H. = SINGLE HUNG H = HOPPER Lu U Z (c) N Lu C)W O � Lu (n o 0 Z Z -r-- M O N � ry m 9716 REGISTERED ARCHITECT HEIDI MICHELLE HELGESON STATE OF WASHINGTON H 2 D A R C H IT E C T U R E D E S+ I G N 23020 EDMONDS WAY, #113 EDMONDS, WA 98020 P.206.542.3734 www.h2darchitects.com DATE: 11/20/2023 PERMIT SET PARTIAL MAIN FLOOR PLAN, WINDOW AND DOOR SCHEDULES RECEIVED Nov 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A1.1 la PARTIAL UPPER FLOOR PLAN SCALE:1/4" = T-0" 0 EXISTING WALLS ® NEW WALLS NOTES: 1. ALL DIMENSIONS ARE GIVEN TO THE FACE OF STUD UNO. 2. ALL DOOR AND WINDOW DIMENSIONS ON THiS PLAN ARE TO CENTERLINE OF ROUGH OPENING U.N.O.; REFER TO SCHEDULES & MANUFACTURER INSTALLATION REQUiREMENTS FOR ROUGH OPENING SiZE. 3. SEE ATTACHED WSEC FORMS AND ENERGY REQUIREMENTS ON 01 FOR ENERGY CODE COMPLIANCE iNFORMATiON. 4. INSTALL SMOKE DETECTORS (S.D.) AT LOCATIONS SHOWN. HARDWIRE AND INTERCONNECT DETECTORS TO POWER SUPPLY AND PROVIDE BATTERY BACKUP AS REQUIRED. 5. INSTALL CARBON MONOXIDE ALARMS (C.M.D.) OUTSIDE EACH SEPARATE SLEEPING AREA iN THE IMMEDIATE VICINITY OF THE BEDROOMS. THE ALARM SHALL BE LISTED AS COMPLYING WiTH UL 2034 AND SHALL BE INSTALLED iN ACCORDANCE WiTH iRC R315.3 AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. HARDWIRE AND INTERCONNECT DETECTORS TO POWER SUPPLY AND PROVIDE BATTERY BACKUP AS REQUIRED. 6. SMOKE DETECTORS (S.D.) AND CARBON MONOXIDE ALARMS (C.M.D.) TO BE INSTALLED 3'-0" MiNiMUM FROM BATHROOM DOORS. W CU Z (c) (N W W C) rn W U) ti o o z Z Q � rn M O N � ry m XL 716 REGISTERED '/ ARCHITECT HEIDI MICHELLE HELGESON STATE OF WASHINGTON H 2 D A R C H IT E C T U R E D E S I G N 23020 EDMONDS WAY, #113 EDMONDS, WA 98020 P.206.542.3734 www.h2darchitects.com DATE: 11/20/2023 PERMIT SET PARTIAL UPPER FLOOR PLAN RECEIVED Nov 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A1.2 I PARTIAL ROOF PLAN SCALE:1/4" = P-0" 0 EXISTING ROOF _ NEW ROOF NOTES: 1. INSTALL ROOF VENTING AS NOTED ON SECTIONS. 2. INSTALL FLASHING PER ROOFING MANUFACTURER REQUIREMENTS. 3. FLASHING AT ALL ROOF PENETRATIONS TO BE iNSTALLEP PER ROOFING MANUFACTURER'S INSTALLATION REQUIREMENTS. 4. INSTALL ALL ROOFING PER SELECTED ROOFING MANUFACTURER'S INSTALLATION REQUIREMENTS, TYP. N W U Z (c) (N W W C) rn W U) ti o o z Z Q � rn M O N � ry m XL 716 REGISTERED '/ ARCHITECT HEIDI MICHELLE HELGESON STATE OF WASHINGTON H 2 D A R C H IT E C T U R E D E S I G N 23020 EDMONDS WAY, #113 EDMONDS, WA 98020 P.206.542.3734 www.h2darchitects.com DATE: 11/20/2023 PERMIT SET ROOF PLAN RECEIVED Nov 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Al .3 INSTALL NEW GUTTER 9 AREA OF iNFiLL, TiE INTO EXISTING, TYP iNFiLL ROOF AT AREA OF EXISTING SKYWALL, REFER TO PLAN SOUTH ELEVATION SCALE:1/4" = 1' 0'' EA I O2 REPLACE XiSTiNG XiSTiNG XiSTiN- T i NEW KITCHEN RANGE HOOD EXHAUST VENT CAP Cad ROOF, INSTALL PER MFR. REQUIREMENTS iNFiLL ROOF AT AREA OF EXISTING SKYWALL, REFER TO PLAN, BUILDING SECTION, & WALL SECTION EXISTING EXISTING EXISTING L L L iNFiLL WALL PER WALL SECTION, INSTALL NEW SiDiNG Cad AREA OF iNFiLL PER SPEC [IN-0-CHANGES PROPOSED ON OTHER ELEVATIONS ---------------------------------------------------------------------- TYP NEW ROOF iNFiLL ASSEMBLY i) 2-1/2" DIAMETER HOLES PER BAY / NON -CORROSIVE WiRE INSECT CREEN KPOSED & PAINTED 2x RAFTER TAiL MATCH EX., O.H. DEPTH TO MATCH EX i 2" T&G SOFFIT TO MATCH EX, AiNT FiNiSH ETAL DRiP EDGE, TYP I I I I ETAL GUTTER TO MATCH EX, EE ALSO ROOF PLAN I PRE -PRIMED CEDAR FASCIA, iMS TO MATCH EX, TYP YP NEW EXTERIOR WALL ASSEMDLY --------------------------- TYP EAVE ASSEMBLY 1" =1'-O" I I I ------------- 5. EX UPPER FLOOR EXTERIOR WALL ASSEMBLY TO REMAIN INSTALL MTL HEADWALL FLASHING (OR VERIFY EX), RUN UP WALL MiN 8" & INSTALL ROOF -TO -WALL EXHAUST VENT PER ROOF PLAN & PET. 2/A2.0 TYP NEW ROOF INFILL ASSEMBLY ASPHALT SHINGLE ROOF TO MATCH EXISTING, TiE INTO EXISTING TYP iCE AND WATER SHIELD OR UNDERLAYMENT PER ROOFING MFR (T.B.5.) CDX PLYWOOD ROOF SHEATHING PER STRUCTURAL ROOF & CEILING FRAMING PER STRUCTURAL BAFFLE FOR 2" MiN AiR SPACE R-49 GATT OR BLOWN-iN INSULATION (RIGID iNSUL. AT PERIMETER AS REQ'D) 5/8" GWB PVA PRIMER & PAINT (PATCH Cad REPAIR EX CLG. FOR SMOOTH CONT. FiNiSH) NEW HEADER PER STRUCT. W/ R-10 RiGiD INSULATION, SEE PET.1/A5.0 NEW PICTURE WINDOW PER SCHEDULE ON 5HT. A1.1, SEE TYP. WINDOW INSTALL DETAILS ON SHT. A5.0 EX UPPER FLOOR ASSEMBLY & STRUCTURAL FRAMING TO REMAIN (ATTACH NEW FRAMING TO EX PER STRUCTURAL) TYP NEW EXTERIOR WALL ASSEMBLY -SiDiNG PER ELEVATION -HENRY BLUESKiN VP100 BUILDING WRAP OR BETTER -CDX PLYWD SHEATHING PER STRUCTURAL -FRAMING PER STRUCTURAL -R-21 DATT INSULATION -1/2" GWB -PVA PRIMER NEW CASEWORK PER PLANS EX MAiN FLOOR ASSEMBLY & STRUCTURAL FRAMING TO REMAIN EX CRIPPLE WALL ASSEMBLY TO REMAIN EX ROOF EL = 23'-5"+/- (T.O. EXISTING RIDGE) EX UPPER FLOOR PLATE EL =17-2 1/4"+/- (T.O. EXISTING PLATE) EX UPPER FLOOR EL = 9'-1 1/8"+/- (T.O. EXISTING SUBFLOOR) EX MAiN FLOOR PLATE EL = 8'-1 1/8"+/- (T.O. EXISTING PLATE) EX MAiN FLOOR EL = 0'-0"+/- (T.O. EXISTING SUBFLOOR) ATTACH NEW ROOF FRAMING TO EXISTING HEADER PER STRUCTURAL TYP NEW VAULTED CEILING/ROOF ASSEMBLY -ASPHALT SHINGLE ROOF TO MATCH EXISTING, TiE INTO EXISTING TYP -iCE AND WATER SHIELD OR UNDERLAYMENT PER ROOFING MFR (T.13.5.) -CDX PLYWOOD SHEATHING PER STRUCTURAL -FRAMING PER STRUCTURAL -BAFFLE FOR 1" AIRSPACE MiN (ADJOIN W/ VENTILATION Ca EX ROOF) -R-38 H.D. GATT OR CLOSED CELL RIGiD INSULATION (VER. DEPTH) -5/8" GWB -PVA PRIMER AND PAINT (PATCH Ca REPAIR EX CLG. FOR SMOOTH CONT. FiNiSH) EX PLATE HT. SEE TYP. EAVE ASSEMBLY (SiM.) VAULTED CLG @ P. BATHROOM 2 1/2" =1'-O" TYP. NEW EXT. WALL A55EM13LY NEW HEADER PER STRUCT. W/ R-10 RiGiD INSULATION, SEE PET.1/A5.0 NEW PICTURE WINDOW PER SCHEDULE ON SHT. A1.1, SEE TYP. WINDOW INSTALL DETAILS ON SHT. A5.0 PARTIAL BUILDING SECTION SCALE:1/4" = 1' 0" EXISTING WALL FiNiSH. OR PATCH TO MATCH EXISTING R-21 GATT INSULATION 9 ALL EXPOSED 2X6 STUD BAYS AND/OR R-15 H.D. GATT AT ALL EXPOSED 2X4 STUD DAYS. R-21 RiGiD OR GATT INSULATION Cad AREAS OF NEW 2X iNFiLL, TYP. EXISTING WALL FRAMING, OR NEW 2X WOOD STUDS 916" O.C. (MATCH EX. WALL THICKNESS) EXISTING EXTERIOR WALL SHEATHING, OR PATCH TO MATCH EX. OR PER STRUCTURAL EXISTING W.R.B., OR PATCH TO MATCH EXISTING EXISTING SiDiNG, OR PATCH TO MATCH EXISTING TYP. WALL INFILL DETAIL SCALE: 11/2"= 10'' TYP. EXT. WALL ASSEMBLY MTL HEADWALL FLASHING - iCE & WATER SHIELD 1/2" SHINGLE OVERHANG ROOFING PER PLANS OVER ROOFING PAPER DRAINAGE PLANE 1" �� \N G 5N� KOOF 1/4" MINIMUM TOP CHORD CAULKING OF ROOF VENT PER MANUFACTURER TRUSS (COR-A-VENT ROOF -TO -WALL VENT) (BEYOND) LIJ U Z � Cv LIJ Q W O � Q Q LIJ (n o 0 Z Z Cy M 0 CN Lij ry IIn 9716 REGISTERED ARCHITECT HEIDI MICHELLE HELGESON STATE OF WASHINGTON H 2 D A R C H I T E CT U R E + D E S I G N 23020 EDMONDS WAY, #113 EDMONDS, WA 98020 P.206.542.3734 www.h2darc h i tects.c om DATE: 11/20/2023 PERMIT SET EXTERIOR ELEVATION, PARTIAL BUILDING SECTION, PARTIAL WALL SECTION RECEIVED Nov 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT EX CRAWL SPACE PARTIAL TYP WALL SECTION SCALE: 1/2" = 1'-0" ROOF -TO -WALL VENT DETAIL SCALE: 11/2"= 1-0" A2.0 iNTER10R R-10 FOAM 0 HEADER HEADER PER STRUCTURAL OR EX15T 1/2" GWE3----- �< GWB WRAP PER TYP DETAIL 7/A5.0 WINDOW LiNER­---� WINDOW PER WINDOW SCHEDULE EXTERIOR -TYP EXTERIOR WALL ASSEMBLY SELF-ADHESIVE WATERPROOF MEMBRANE INSTALL PER 4/A5.0 MTL FLASHING OVER WD TRiM WD TRiM PER TYP DETAIL 6/A5.0 TYP WINDOW HEAD TYP EXTERIOR WALL ASSEMBLY WD TRiM PER TYP DETAIL 6/A5.0 SELF-ADHESIVE WATERPROOF MEMBRANE INSTALL PER 4/A5.0 GWB WRAP PER TYP DETAIL 7/A5.0 1/2" GWB TYP WINDOW JAMB Illms SiLL PER TYP DETAIL (VERIFY W/ CLIENT FiNiSH MATERIAL & INTEGRATION WiTH COUNTER AT KITCHEN LOCATION) 2x WD SiLL W/ SLOPE & DRiP SELF-ADHESIVE WATERPROOF MEMBRANE, INSTALL PER 4/A5.0 TYP EXTERIOR WALL ASSEMBLY INTERIOR EXTERIOR TYP WINDOW SILL 1" =1,-0" TYPICAL WINDOW NOTE: 1. INSTALL BACKER ROD AND/OR FOAM INSULATION C� ANY GAP BETWEEN WINDOW AND ROUGH FRAME, TYP 20 TRiM W/ MITERED CORNERS TO MATCH EXISTING, TYP. WINDOW PER WINDOW SCHEDULE PROVIDE SLOPE & DRiP EDGE @ SiLL TRiM, TYP. TYP EXT. WN DW TRIM 1" =1,-0" *VER TO MATCH EXISTING WINDOW LINER TO MATCH EXISTING, TYP. DRYWALL WRAP 0 ALL SIDES TO MATCH EXISTING, TYP. WINDOW PER WINDOW SCHEDULE TYP I NT. WN DW TRIM *VER TO MATCH EXISTING TAPE WEATHER KES15TiVE BARRIER G INSTALLED WINDOW WATERPROOF AIRTIGHT TAPE WEATHER RESISTIVE WINDOW FLASHING 1. CUT THE WRB FLUSH WiTH THE ROUGH OPENING 2. CUT THE WRB AT 45 DEGREE ANGLE TO A POINT 9" UP AND 9" OUT FROM THE UPPER CORNERS OF THE ROUGH OPENING 3. FOLD UP WRB FLAP AT HEAD AND TEMPORARILY SECURE WiTH MASKING TAPE 50 THAT iT CAN BE INSTALLED OVER THE HEADER FLANGE OF THE WINDOW LATER. 4. FOLD BACK THE OTHER TWO EDGES OF THE WRB INTO THE ROUGH OPENING AND SECURE BY STAPLING. TO ENSURE POSITIVE DRAINAGE OF THE SiLL/PREVENT WATER INTRUSION, ADD A BACK DAM OR SLOPE SiLL AT THE BOTTOM OF THE R.O. 5. INSTALL SiLL TAPE ON WINDOW SiLL, EXTENDING iT UP EACH SiDE A MiN OF 4". ACCURATELY PRESS INTO CORNERS. OVERLAP THE VERTICAL FACE OF THE WRB APPROXIMATELY MiN 1". TRiM AND PRESS/STRECH AROUND BOTH CORNERS. FOLD UP WEATHER RESISTIVE BARRIER AND TEMPORARILY SECURE EXTERIOR SHEATHING SiLL PLATE SiLL TAPE (WATERPROOF, AIRTIGHT TAPE) 6. INSTALL FLANGED WINDOW AND FASTEN TO STRUCTURE PER MFR'S iNSTRUCTIONS. 7. WRB AT TOP FLANGE: UNFOLD WRB AND RUN iT OVER THE TOP OF FLANGE. 8. FLANGE TAPE: USE FLANGE TAPE TO SEAL BOTTOM FLANGE TO THE WRB. PRESS FIRMLY TO AFFIX. 9. TAPE THE 51PE FLANGES TO THE WRB. 10. TAPE THE WRB TO THE TOP FLANGE 11. TAPE THE DIAGONAL CUTS IN THE WRB ABOVE THE WINDOW HEAD. *NOTE: MAKE SURE TAPING 15 DONE FROM BOTTOM TO TOP 50 THAT ALL TAPE JOINTS ARE PROPERLY SHiPLAPPED. TYP WINDOW FLASHING DTL N.T.S. DOOR, WHERE OCCURS CL TiLE FLOORING SCHLUTER TRANSITION STRIP, ALUMINUM CARPET 5UBFLOOR TYP TILE TO CRPT TRANSITION 1-1/2" =1'-0" OR APPROVED EQUAL TYP WALL ASSEMBLY 1/2"X WOOD BASE TO MATCH EXISTING, PAINTED FiNiSH FLOORING TYP WD BASE DTL 9 3/4" =1'-0" *VER TO MATCH EXiSTiNG O WATERPROOF AIRTIGHT TAPE FOR SEALING AROUND DOORS / O DOOR FLASHING 1. CUT THE WRB FLUSH AT THE DOOR R.O. / 2. AT THE DOOR R.O. HEAD, CUT THE WRB AT 45 DEGREE ANGLE TO A POINT 9" UP AND 9" OUT FROM THE UPPER CORNERS OF THE ROUGH OPENING 3. FOLD UP WRB FLAP AT HEAD AND TEMPORARILY SECURE WiTH MASKING TAPE 50 THAT iT CAN BE INSTALLED OVER THE HEADER FLANGE OF THE WINDOW LATER. 4. FOLD BACK THE OTHER TWO EDGES OF THE WRB INTO THE ROUGH OPENING AND SECURE WiTH AIRTIGHT TAPE. ADD A BACK DAM OR SLOPE SiLL AT THE BOTTOM OF THE R.O. 5. INSTALL WATERPROOF AIRTIGHT TAPE ON SiLL AND INTO FULL DEPTH OF ROUGH OPENING, EXTENDING iT UP EACH SiDE A MiN OF 6". ACCURATELY PRE55 INTO CORNERS. OVERLAP THE VERTICAL FACE OF THE WRB APPROXIMATELY MiN 3". TRiM AND PRE55/STRECH AROUND BOTH CORNERS. FATHER -RESISTIVE TEMPORARILY WEATHER -RESISTIVE WRAP INTO OPENING WATERPROOF AIRTIGHT TAPE LEDGER FLASHING SEAL TOP OF JOISTS UNDER DECKING 6. INSTALL WP AIRTIGHT TAPE ON THE JAMB AND INTO THE FULL INTERIOR DEPTH OF THE ROUGH OPENING OVERLAPPING THE WRB. 7. INSTALL WP AIRTIGHT TAPE TO THE HEAD 8. TAPE THE DIAGONAL CUTS iN THE WRB ABOVE THE DOOR HEAD. *NOTE: MAKE SURE TAPING 15 DONE FROM BOTTOM TO TOP 50 THAT ALL TAPE JOINTS ARE PROPERLY SHiPLAPPED. TYP DOOR FLASHING DTL @EXTERIOR N.T.S. OR APPROVED EQUAL `,L CL DOOR, WHERE OCCURS DOOR, WHERE OCCURS FiNiSH WOOD FLOORING FiNiSH WOOD FLOORING SCHLUTER TRANSITION SCHLUTER SCHIENE TRANSITION STRIP, ALUMINUM CARPET TiLE FLOORING SUBFLOOR �SUBFLOOR IT-STRiP, ALUMINUM TYP WD TO CRPT TRANSITION 1-1/2" =1'-0" I TYP WD TO TILE TRANSITION 1-1/2" =1'-O" w U Z � Cv w Q W O U) w U) ti CDZ 0 z V Cy M O CN Lij L.L 9716 REGISTERED ARCHITECT HEIDI MICHELLE HELGESON STATE OF WASHINGTON H 2 D A R C H I T E C T U R E D E S I G N 23020 EDMONDS WAY, #113 EDMONDS, WA 98020 P.206.542.3734 www.h2darchitects.com DATE: 11/20/2023 PERMIT SET TYP. DETAILS RECEIVED Nov 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A5.0 STRUCTURAL NOTES (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) CODE ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION. SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. DESIGN LOADS DEAD LOADS: ROOF 15 PSF LIVE LOADS: ROOF (SNOW LOAD) 25 PSF STATEMENT OF SPECIAL INSPECTIONS SPECIAL INSPECTIONS ARE NOT REQUIRED. STRUCTURAL OBSERVATION OF THE STRUCTURAL SYSTEM BY THE ENGINEER IS NOT REQUIRED. LUMBER ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fc (PSI) LIGHT FRAMING (STUDS) HEM -FIR STUD 675 800 2x JOISTS AND PLANKS HEM -FIR #2 850 - PLATES AND BLOCKING HEM -FIR #2 850 - 6x AND LARGER BEAMS AND STRINGERS DOUG-FIR #2 875 - 4x AND SMALLER BEAMS AND STRINGERS HEM -FIR #2 850 - ALL POSTS AND TIMBERS DOUG-FIR #1 1200 1000 REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1. NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: NAIL SHANK 0 MIN LENGTH 8d COMMON 0.1310 2 1/2" SHANK 10d COMMON 0.1480 3" SHANK 12d COMMON 0.1480 3 1/4" SHANK 16d COMMON 0.1620 3 1/2" SHANK 10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148" 0 x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE SHANK AND THREADED PORTIONS PER NDS 12.1.4.2. CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS, SCREWS, OR BOLTS IN EACH MEMBER. INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. GALVANIZATION UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED ACCORDING TO THE FOLLOWING TABLE: GALVANIZATION UNTREATED WOOD CCA-C SBX ACQ-C ACQ-D CBA-A CA-B OTHER BORATE ACZA OTHER PT WOOD G90 X X X G 185 X X X X X X HDG X X X X X X STT300 X X X X X X X X G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA HDG = HOT DIP GALVANIZED SST300 = TYPE 316L STAINLESS STEEL RATED SHEATHING RATED SHEATHING SHALL BE GRADE C-D INT-APA WITH EXTERIOR GLUE OR OSB SHEATHING WITH EXTERIOR GLUE IN CONFORMANCE WITH IBC STANDARD 2303.1.5. EXISTING BUILDING CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. CONTRACTOR TO SEE ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. LEGEND DEFINITION SYMBOL DEFINITION SYMBOL DIRECTION OF FRAMING pp NATIVE SOIL — — — — EXTENT OF FRAMING GRANULAR FILL COLUMNS STRUCTURAL STEEL COLUMN BEARING ON BEAM P RATED SHEATHING BEAM CONTINUOUS OVER SUPPORT 0 SHEAR WALL (SEE SCHEDULE) SWX CONCRETE WALL COLUMN MARK (SEE SCHEDULE) / BEARING STUD El�FOOTING MARK O WALL (SEE SCHEDULE) NON -BEARING HOLDOWN MARK STUD WALL (SEE SCHEDULE) BEARING STUD HANGER MARK SHEAR WALL (SEE SCHEDULE) O NON -BEARING FLAG NOTE STUD SHEAR WALL (SEE PLAN NOTES) CMU WALL STEEL MOMENT FRAME CONN. �V ADJACENT NAILS IN A ROW ARE TO BE DRIVEN FROM OPPOSITE SIDES, TYP C G ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 PARTIAL UPPER FLOOR AND LOWER ROOF FRAMING PLAN SCALE: 1/4" = V-0" TYPICAL ROOF FRAMING PLAN NOTES: 1. ROOF SHEATHING SHALL BE 1/2" PI 40/20 WITH 8d COMMON NAILS SPACED AT 6" OC AT ALL DIAPHRAGM BOUNDARIES, PANEL EDGES, SHEAR WALLS, COLLECTOR TRUSSES, AND BLOCKING OR TRUSS BLOCKING PANELS INDICATED ON PLANS. NAILING AT INTERMEDIATE FRAMING SHALL BE 8d COMMON NAILS @ 12" OC. 2. ALL STUD WALLS SHALL BE 2x HF STUD AND SPACED AT 16" OC. FOR 2x4 STUDS, PROVIDE SINGLE ROW OF NAILS STAGGERED EA SIDE WITH 1 1/2" EDGE DISTANCE. FOR 2x6 STUDS, PROVIDE (2) ROWS OF NAILS SPACED AT 2 1/2" W/ 1 1/2" EDGE DISTANCE 9" OC MAX SPACING BETWEEN ADJACENT NAILS IN A ROW 0.131" 0 x 3" NAILS, TYP (5) STUDS MAX TO BE USED FOR BUILT-UP COLUMNS TYPICAL BUILT-UP STUD COLUMN DETAIL SCALE: 1" = V-0" TYP DOUBLE TOP PLATE DESIGN: MRD DRAWN: LVW EXISTING STUD WALL CHECK: DTR SIMPSON A34 (ONLY LRUZ OR SLOPED HU REQUIRED AT EXTERIOR HANGER 2x LEDGER W/ (2) 1/4"0 JOB NO: 23324.10 HEADERS GREATER THAN U SPAN) ROOF SHEATHING AND NAILING STUDDS SCREWS @ EA DATE: 1 1 /1 7/23 PER ROOF FRAMING PLAN NOTES RAFTER PER PLAN (6) 0.131"� x 3" NAILS DIAPHRAGM BOUNDARY NAILING PER ROOF FRAMING PLAN NOTES FULL DEPTH BLKG RIPPED TO TYPICAL STUDS BEAM OR HEADER PER MATCH SLOPE OF ROOF PLAN AND NOTES NAILING PER TYP / /1 BUILT-UP STUD COLUMN DETAIL EXISTING BEAM PER PLAN V J PROVIDE PLYWOOD/OSB A35 CLIP @ 12" OC (1) 2x FULL HT CRIPPLE STUDS PER PLAN SHEATHING TO MATCH EXISTING. SIMPSON H2.5A TIE LUS HANGER O AND COLUMN SCHEDULE FASTEN SHEATHING TO STUD W/ 8d NAILS 6" OCT ALL PANEL @ EA TRUSS 2x4 HF#2 CEILING JOISTS O W OR STRUCTURAL NOTES @ EDGES & @ 12" OC IN FIELD STUD WALL FRAMING @ 16" OC N 0 L.L PER PLAN NOTES TYPICAL HEADER DETAIL SCALE: 1" = V-0" TYPICAL RAFTER SUPPORT DETAIL SCALE: 1" = V-0" DIAPHRAGM BOUNDARY NAILING PER ROOF FRAMING PLAN NOTES FULL DEPTH BLI<G RIPPED TO MATCH SLOPE OF ROOF ROOF SHEATHING AND NAILING PER ROOF FRAMING PLAN NOTES ROOF RAF PER PLAN A35 CLIP @ 24" OC PROVIDE PLYWOOD/OSB SIMPSON H2.5A TIE SHEATHING TO MATCH EXISTING. FASTEN SHEATHING TO STUD STUD WALL FRAMING W/ 8d NAILS @ 6" OC T ALL PER PLAN NOTES PANEL EDGES & @ 12" OC IN FIELD TYPICAL RAFTER SUPPORT DETAIL SCALE: 1" = V-0" JG RAFTER R LI\VL JR SLOPED HU HANGER ^0 � Z uj 0 La N � Z Z v Z 0 J > Qa Q� J oLa V/ I � o U Z Z 0 Z ( " V) il lIx 0 L` w m N w (/) L- z U- SHEET: RECEIVED Nov 28 2023 OF SNDS EVE PMEN ERVICES E PART NT ■