Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED BLD RESUB1 BLD2024-0685+Arch_Plans+6.14.2024_10.07.04_AM+4322993
MATERIAL KEY de. a.. CONCRETE CONTINUOUS STRUCTURAL s FRAMING MEMBER GRAVEL FILL BLOCKING (NOT CONTINUOUS) -� UNDISTURBED SOIL WOOD FINISH MATERIAL SAND FILL PLYWOOD RIGID INSULATION i HIDDEN OR BURIED MATERIAL IN ANOTHER MATERIAL BATT INSULATION MASONRY -BRICK OR CONCRETE BLOCK ABBREVIATIONS AFF ABOVE FINISH FLOOR MECH. MECHANICAL & AND MFR. MANUFACTURER @ AT MIN. MINIMUM APPROX. APPROXIMATE(LY) M.O. MASONRY OPENING N.I.C. NOT IN CONTRACT BD. BOARD N.T.S. NOT TO SCALE BLDG. BUILDING # NUMBER rL CENTER LINE O.C. ON CENTER CLG. CEILING OPG. OPENING C.I. CONTINUOUS INSULATION O/ OVER C.J. CONTROL JOINT CMU. CONCRETE MASONRY UNIT PARALLEL CONC. CONCRETE 1 PERPENDICULAR CONT. CONTINUOUS LB. or # POUNDS C.T. CERAMIC TILE P.S.F. POUNDS PER SQUARE FOOT P.S.I. POUNDS PER SQUARE INCH D. DRYER P.T. PRESSURE TREATED DW DISH WASHER DIA. DIAMETER REBAR REINFORCING STEEL ° DEGREES REQ'D REQUIRED D.S. DOWNSPOUT REQ'M REQUIREMENT DWG. DRAWING R. RISERS RE. REFER or REGARDING EA. EACH REF. REFRIGERATOR E.J. EXPANSION JOINT R.D. ROOF DRAIN ELEC. ELECTRICAL R.O. ROUGH OPENING EL. ELEVATION R.S. ROD AND SHELF EQ. EQUAL EQUIP. EQUIPMENT S.D. SMOKE DETECTOR EX. EXISTING S.C. SOLID CORE EXT. EXTERIOR S.F. SQUARE FOOT/FEET SIM. SIMILAR F.D. FLOOR DRAIN SPEC. SPECIFICATIONS F.O.S. FACE OF STUD S.S. STAINLESS STEEL F.R. FIRE -RETARDANT STD. STANDARD FT. or' FOOT/FEET STR. STRUCTURAL F.F.L. FINISH FLOOR LEVEL T. TREAD GA. GAUGE OR GAGE T.O.B. TOP OF BEAM G.C. GENERAL CONTRACTOR T.O.C. TOP OF CONCRETE GALV. GALVANIZED T.O.W. TOP OF WALL GLULAM. GLUE LAMINATED LUMBER T&G TONGUE AND GROOVE GYP. BD. GYPSUM BOARD TYP. TYPICAL H or HT. HEIGHT U.L. UNDERWRITER'S LABRATORY H.C. HOLLOW CORE U.O.N. UNLESS OTHERWISE NOTED H.M. HOLLOW METAL HORIZ. HORIZONTAL V.I.F. VERIFY IN FIELD IN. or INCH(ES) W. WIDTH INT. INTERIOR W/ WITH W/IN WITHIN JT. JOINT W.C. WATER CLOSET W. WASHER LAV. LAVATORY W.W.M. WELDED WIRE MESH LVL. LAMINATED -VENEER LUMBER WD. WOOD MAX. MAXIMUM BUILDING ENVELOPE COMPLIANCE: BUILDING ENVELOPE COMPLIANCE TO BE PRESCRIPTIVE IN ACCORDANCE WITH WSEC R401.2 AND ALL ASSEMBLIES TO MEET R VALUES SET IN TABLE R402.1.1. PROJECT INSULATION R & U VALUES WINDOWS & DOORS: U 0.30 SKYLIGHTS: U 0.50 ROOF AND CEILING @ TRUSSES: R-60 ROOF AND CEILING @ RAFTERS: R-38 WALLS @ ABOVE GRADE: R-20 + 5 or R-13 + 10 WALLS @ BELOW GRADE: R-10/15/21 int. + 5TB FLOORS @ CRAWL SPACE: -30 FLOORS @ SLAB R-10 W/IN 4' FROM PERIMETER DRAWING SYMBOL KEY GRID BUBBLE OGRID NO. DETAIL TAG Z DETAIL NO. A3.3 SHEET NO. SECTION TAG 3 SECTION LETTER A3.2 SHEET NO. DOOR TAG 100 DOOR NO. WINDOW TAG T WINDOW NO. <✓> WALL TYPE SMOKE & CARBON MONOXIDE DETECTORS SCD OO SMOKE DETECTOR ® SCD COMBINATION SMOKE & CO DETECTOR GENERAL NOTES CEILING HEIGHT TAG 8'-0" CEILING HEIGHT DIMENSION INTERIOR ELEVATION TAG ELEVATION NO. SHEET NO. FINISH TAG CPT-1 FINISH TYPE & NO. W. VICINITY MAP KEYNOTE TAG O5 KEYNOTE NO.+� f r �• rt` SAFETY GLAZING r. ; SG SAFETY GLAZING _ FAN FI g90 CFM EXHAUST FAN W/ CFM PROJECT LOCATION DATUM TAG DATUM LEVEL 1. THESE CONSIST OF THE DRAWINGS, AND OTHER DOCUMENTS LISTED IN THE CONTRACT BETWEEN OWNER AND ARCHITECT. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. 2. THESE DRAWINGS, THE DESIGN CONTAINED WITHIN AND AS CONSTRUCTED ARE COPYRIGHT 2023 BY PELLETIER + SCHAAR, L.L.C.; AUTHORIZED USE OF THESE DRAWINGS ARE GRANTED SOLEY FOR THE PURPOSE OF THIS SPECIFIC PROJECT AND LOCATION. 3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, SUBCONTRACTORS AND MATERIAL SUPPLIERS TO CAREFULLY EXAMINE EACH PAGE OF THE DRAWINGS. THE CONTRACTOR SHALL PROMPTLY NOTIFY THE ARCHITECT IF THE DRAWING ARE OBSERVED TO BE AT VARIANCE. 4. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH LOCAL CONDITIONS AND FIELD VERIFY EXISTING CONDITIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ARCHITECT OF DISCREPANCIES OR CONDITIONS THAT HINDER THE COMPLETION OF WORK PER THE CONTRACT DOCUMENTS - PRIOR TO WORK BEING DONE. 5. ALL DIMENSIONS ARE ±, WHETHER NOTED OR NOT, AND SHALL BE FIELD VERIFIED AT EXISTING CONDITIONS. 6. THE CONTRACTOR SHALL PROCURE AND PAY FOR NECESSARY PERMITS. 5. WORK SHALL INCLUDE PROVIDING ALL FORMS OF PROTECTION AS NECESSARY TO PRESERVE THE WORK OF OTHER TRADES, FREE FROM DAMAGED, ALL TRADES SHALL PROTECT THEIR OWN WORK TO PREVENT DAMAGE BY OTHER DURING COURSE OF CONSTRUCTION. FINISH SURFACES SHALL BE PROPERLY PROTECTED AT TIME OF INSTALLATION. 7. FINAL ORIENTATION FOR THE BUILDING ON THE SITE AND ESTABLISHMENT OF FLOOR LEVEL BENCH MARK SHALL BE REVIEWED BY THE ARCHITECT. 8. BEFORE ORDERING ANY MATERIAL OR STARTING ANY WORK WHICH MAY BE AFFECTED BY ADJACENT WORK OF OTHERS, CONTRACTOR SHALL VERIFY MEASUREMENTS AT BUILDING AND BE RESPONSIBLE FOR CORRECTNESS OF THESE MEASUREMENTS. 9. DRAWING SHALL NOT BE SCALED. NOTED DIMENSION TAKE PRECEDENCE OVER SCALED DIMENSIONS. WINDOW, CABINETS, AND ALL SHOP BUILT ITEMS SHALL BE FIELD MEASURED PRIOR TO FABRICATION AND INSTALLATION. FINAL LOCATIONS OF SWITCHES, FIXTURES, GRILLES, COVERS, ETC. SHALL BE DETERMINED ON THE JOB. VERIFY EXACT LOCATIONS WITH ARCHITECT BEFORE ROUGH -IN. 10. ROUGH FRAMING HORIZONTAL DIMENSION ARE SHOWN FROM FACE OF STUD TO FACE OF STUD. ROUGH FRAMING VERTICAL DIMENSION ARE SHOWN FROM TOP OF CONCRETE SLAB TO TOP OF FLOOR SHEATHING TO TOP OF WALL PLATE. 11. WORKMANSHIP SHALL CONFORM TO BEST STANDARDS AND HIGHEST QUALITY OF TRADES AND SHALL INCLUDE ALL ITEMS OF FABRICATION, CONSTRUCTION, AND INSTALLATION. WORK SHALL BE EXECUTED BY SKILLED MECHANICS. WHEN COMPLETE, ALL PARTS SHALL BE DURABLY AND SUBSTANTIALLY BUILT AND SHALL PRESENT A NEAT WORKMAN - LIKE APPEARANCE. 12. INSTALL EQUIPMENT AND MATERIALS IN STRICT ACCORDANCE WITH MANUFACTURE'S CURRENT PUBLISHED INSTRUCTIONS AND RECOMMENDATIONS. DEMOLITION GENERAL NOTES 1. THESE NOTES INDICATE THE GENERAL EXTENT OF DEMOLITION. REMOVE AND DISPOSE OF MATERIALS AND EQUIPMENT WHICH ARE NOT INCORPORATED IN NEW WORK OR (E) TO REMAIN. PROTECT ELECTRICAL SERVICE, WATER SERVICE AND OTHER TO THAT WHICH ARE TO REMAIN. 2. REFER TO REMAINDER OF ARCHITECTURAL PLAN(S) AND VERIFY NEW SYSTEM LAYOUTS PRIOR TO COMMENCING DEMOLITION. 3. REMOVE ALL DEBRIS FROM SITE TO A LICENSED DISPOSAL SITE. 4. COORDINATE WITH LOCAL UTILITY COMPANIES AND CITY OF EDMONDS FOR SHUT DOWN AND RECONNECT OF SERVICES. 5. PROTECT ALL PUBLIC PUBLIC WAYS AND ADJACENT PROPERTIES. 6. WORK SEQUENCES AND SCHEDULES TO BE APPROVED BY OWNER BEFORE WORK COMMENCES. 7. PROVIDE TEMPORARY BARRIERS AND FENCING TO GUARD AND PROTECT WORK AREA. 8. HAZARDOUS MATERIALS MAY BE EVIDENT AT THE SITE IF CONTRACTOR ENCOUNTERS ASBESTOS -CONTAINING OR OTHER HAZARDOUS MATERIALS NOT PREVIOUSLY INDICATED THEY ARE TO STOP WORK AND NOTIFY OWNER. SCOPE OF WORK INTERIOR REMODEL OF EXISTING RESIDENCE - ALTERATIONS TO EXISTING KITCHEN, DINING, LIVING AND PRIMARY BED & BATHROOM PROJECT INFORMATION ADDRESS: 821 BELL ST, EDMONDS, WA 98020 PARCEL NO.: 00434207902800 ZONING: RS-6 LEGAL DESCRIPTION: CITY OF EDMONDS BLK 079 D-00 LOT 29, 30 & W 13FT OF LOT 28PER CITY EDM LLA #LL-96-98 REC AF NO 9702270433 LOT AREA: 0.18 ACRES, 7,840.8 S.F. BUILDING AREA: 1,535 S.F. FIRST FLOOR FINISHED - EXISTING 2,432 S.F. TOTAL FINISHED - EXISTING 582 S.F. GARAGE - EXISTING 377 S.F. DECKS - EXISTING APPLICABLE BUILDING CODES 2021 INTERNATIONAL BUILDING CODE 2021 WASHINGTON STATE BUILDING CODE 2021 WASHINGTON STATE ENERGY CODE 2021 INTERNATIONAL FIRE CODE 2021 INTERNATIONAL MECHANICAL CODE 2021 INTERNATIONAL PLUMBING CODE CITY OF EDMONDS, WA. AMENDMENTS AND ORDINANCES PROJECT ENERGY CREDITS PROVIDED: N/A HEIGHT CALCULATIONS: '. ' OBTAIN ELECTRICAL N/A PERMIT FROM STATE LABOR & '. •. INDUSTRIES 1 1 OBTAIN A SEPARATE •. PLUMBING PERMIT FROM THE CITY OF • EDMONDS. 1 _. 1 _.._........ ...... _.._.._.._........ ...... _.._........ _..� WHERE ADDITIONS OR ALTERATIONS REQUIRE A PERMIT TO BE ISSUED INTERCONNECTED SMOKE ALARM AND CO DETECTORS THROUGHOUT THE DWELLING IS REQUIRED. j 1 � REFER TO 2021 IRC R314 AND 315 FOR MORE INFORMATION. 1 1 DRAWING INDEX GENERAL G0.1 GENERAL NOTES, LEGENDS & ABBREVIATIONS ARCHITECTURAL A1.0 FOUNDATION PLAN A1.1 FIRST FLOOR PLAN & WINDOW SCHEDULE A1.2 SECOND FLOOR PLAN & DOOR SCHEDULE A2.1 NOT USED A3.1 ELEVATIONS STRUCTURAL S0.0 GENERALNOTES S0.1 GENERAL NOTES S1.0 FOUNDATION PLAN S1.1 FIRST FLOOR FRAMING PLAN S1.2 SECOND FLOOR FRAMING PLAN S2.0 ROOF FRAMING PLAN S3.0 SHEARWALL AND HOLDOWN LAYOUT S3.1 SHEARWALL AND HOLDOWN LAYOUT S4.0 STRUCTURAL FRAMING DETAILS PROJECT TEAM OWNER: ADDRESS: PHONE: CONTACT PERSON: ARCHITECT: ADDRESS: PHONE: CONTACT PERSON: CONSULTANT: ADDRESS: PHONE: CONTACT PERSON: GENERAL CONTRACTOR: ADDRESS: PHONE: CONTACT PERSON: JOSE IZQUIERDO & MADELINE MERCIER 821 BELL ST, EDMONDS, WA 98020 XXX-XXX-XXXX PEPE IZQUIERDO PELLETIER + SCHAAR, LLC 26911 98TH DR. NW, STE. B, STANWOOD, WA 98292 360-629-5375 DAVID PELLETIER, AIA STRUCTURAL WORKS PLLC 1412 BEACH DRIVE NE #A, TACOMA, WA 98422 (253)533-0835 ERCIN SAHIN, P.E. 7U FULLWILER CONSTRUCTION INC. 526 N. WEST AVE, SUITE 147 W 360-631-5922 Q LISA HAUS rr_^^ VJ L.L V Z City Of Edmonds Building Department Work -------------------------------------------------------- INTERIOR REMODEL -------------- Address ------ 821 BELL ST Owner --------------- IZQUIERDO ----------------------- Approved Date --------------------------------- 6/21/2021 --------------------------------- Building Official:: ,-------------------------------------------- Permit Number ---------------------------------------- gLD2024-0685 APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE I- VJ X W O U) Z O RESUB Q Jun 14 2024 CITY OF EDMONDS W DEVELOPMENT SERVICES DEPARTMENT REV.. 10. 6/6/2024- BUILDING COMMENTS Q PELLETIER(+) SCHAAR O v151un BaSt--U /-,r �_rlltectUi t_- 26911 98th Dr. NW, Suite B Stanwood, WA 98292 W www.peIletierschaar.c0m 36o-629-5375 Z NO.:XXXXXX DRN:XXX CHK:XXX © 2023 PELLETIER + SCHAAR, L.L.C. b Q 6946 REGI TERED CHI ECT W DA 4D PELLETIER STATE OF WASHINGTON 0.1 5/17/2024 N NOTE: ALL INFILL WALLS SEE NOTES ON FLOOR PLANS GENERAL NOTES. LEGENDS & ABBREVIATIONS 69'-2" ± 15-62" ± 6'-11�2" ± 9'-6" ± 14'-4" ± 8'-6" ± 12'-0" ± 2'-4" ± / \ +I EXISTING CRAWL SPACE ACCESS F \\— — — — — — — — — — — — L- -- --- --� — — — — — — — — — — +I o ------------� J--------------- I I +I EXISTING CONC. \ \ \ SLAB EXISTING FJOTINGS AND FOUNDATION WALLS — — +I EXISTING CRAWL W SPACE NEW FOOTINGS SEE STRUCTURAL 15'-4" TO BE PLACED UNDER NEW BEAM z \ u / POINT LOADS ABOVE W \ / LOCATIONS TO BE VERIFIED IN THE Q \ / FIELD. I � IFI I U) - - - - - - - - - - - - - - J +I W ---- N U) 10 w N / / / +I o ti co / RESUB z Jun 14 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT I � I I L------------------� W — — — — — — — — — — — — — — — — J J Q NOTES: P E L L E T I E R O+ S C H A A R O ALL DIMENSIONS SHOWN ± ALIGN WITH EXISTING CONSTRUCTION Vision Baseu Hf uii Itectui � 16'-10" ± 17'-0" ± 9'-8" ± 26'-4" ± AND TO BE VERIFIED IN THE FIELD. 26911 98th Dr. NW, Suite B • Stanwood, WA 98292 W www.pelletierschaar.com • 36o-629-5375 z NO.: XXXXXX DRN: XXX CHK: XXX © 2023 PELLETIER + SCHAAR, L.L.C. b PROJECT NORTH 69CWASHINGTON FOUNDATION PLAN LLJ SCALE 1/4"= l'-O" 0' 4' 8' DA STAAl m 5/17/2024 N BUILDING PERMIT - FOUNDATION PLAN. / WINDOW SCHEDULE NO. STYLE LOCATION DIMENSIONS NOTES AREA TYPE VENT 1 A SLID 5/0 X 3/6 SAFETY GLASS 17.5 S.F. 2 B SLID 6/0 X # SAFETY GLASS 30 S.F. TOTAL WINDOW GLAZING 47.5 S.F. NOTE: ALIGN OPERABLE WII` WITH EXISTING (FIELC r o - + E 9 0 CV A71 n 1 PHASING LEGEND EXISTING CONSTRUCTION TO REMAIN ITEMS TO BE DEMOLISHED NEW CONSTRUCTION PLAN GENERAL NOTES 1. WALLS, CEILING AND FLOOR INSULATION; AND WINDOW AND DOOR GLAZING TO BE IN ACCORDANCE 2021 WSEC. SEE SHT. A0.1. 2. TEMPERED SAFETY GLAZING TO BE PROVIDED PER 2021 IRC SECTION R308.4; SEE ELEVATIONS OR WINDOW SCHEDULE FOR LOCATIONS. 3. INSTALL 110V SMOKE DETECTORS, INTERCONNECT W/ BATTERY BACKUP, PER 2021 IRC WA STATE AMENDMENTS SECTION R314; SEE PLANS FOR LOCATIONS. INSTALL A B SAFETY GLASS / X � 4 AMENDM NTSOSECTIIONN R3D15 SEE FLOOR PLAN OFOR LO AT ONS.E NOTE: FOR DOOR SCHEDULE SEE A1.2 NOTES: ALL DIMENSIONS SHOWN ± ALIGN WITH EXISTING CONSTRUCTION AND TO BE VERIFIED IN THE FIELD. \ \ i AREA OF REMODEL PROJECT NORTH co 0 N FIRST FLOOR PLAN SCALE 1/4"= l'-O" 0' 4' 8' 5. INSTALL WHOLE HOUSE VENTILATION FAN PER 2021 IRC WA STATE AMENDMENTS SECTION M1507.1 SYSTEM SHALL PROVIDE MIN. CFM PER TABLE M1507.3.3(1). 6. ALL EXHAUST FANS TO BE LOCATED AND SIZED PER 2021 IRC WA STATE AMENDMENTS TABLE M1507.4. 7. FAN NOISE RATING TO BE 1.5 SONE OR BETTER 8. PROVIDE MIN. 15" FROM CENTER OF TOILET TO ADJACENT WALL OR OTHER OBSTRUCTION AND 21" CLEARANCE DIRECTLY IN FRONT OF TOILET PER 2021 IRC SECTION R307.1. 9. EXISTING CEILING, WALL OR FLOOR CAVITIES EXPOSED DURING CONSTRUCTION PROVIDED THESE CAVITIES ARE FILLED WITH INSULATION. 2x4 FRAMED WALLS SHALL BE INSULATED TO A MINIMUM OR R-15 AND 2x6 FRAMED WALLS SHALL BE INSULATED TO A MINIMUM OR R-21. PLAN KEYNOTES 1O 110V COMBINATION SMOKE & CARBON MONOXIDE DETECTOR INTERCONNECT W/ BATTERY BACKUP TYP. 0 ROOF LINE ABOVE OR WALL BELOW 0 CONTINUOUSLY OPERATING FAN, 60 CFM, IN ACCORDANCE WITH ANSI/AMCA 210-ANSI / ASHRAE 51. SECTION Ml505 2021 IRC AND TABLE Ml505.4.3(1) U.L. APPROVED PROPANE BURNING FIREPLACE 0 DRYER - VENT TO OUTSIDE EXHAUST TERMINATION - IN ACCORDANCE WITH IRC M 1507.3.4.4 O7 PROVIDE EMERGENCY ESCAPE OPENING IN ALL SLEEPING ROOMS MIN. 24" HIGH X 20" WIDTH AND 5.7 S.F CLEAR OPEN AREA IN ACCORDANCE WITH IRC R310.1 22" X 30" ATTIC ACCESS - WITH MIN. UNOBSTRUCTED HEADROOM ABOVE HATCH OF 30" 0 RANGE WITH 300 CFM HOOD 10. 5/8" TYPE-X GWB ON ALL WALLS & CEILING AND AROUND ALL BEAMS AND POSTS. 11. SOLID CORE DOOR W/ SELF CLOSER 12. TOWEL WARMER (NOT USED) 13. 5/8" TYPE X GWB UNDER STAIR 14. ROD & SHELF DOOR & WINDOW NOTES 1. SEE SHT. AO.1 FOR 2021 WSEC REQUIREMENTS; ALL EXTERIOR DOORS AND WINDOWS SHALL COMPLY. 2. SEE FLOOR PLAN FOR SLIDING / POCKET DOOR ACTIVE DOOR PANEL LOCATIONS AND DIRECTIONS. 3. SEE ELEVATIONS FOR OPERABLE WINDOW SASH DIRECTIONS. 4. ALIGN WINDOW AND DOORS HEADS - TYP. 5. ALL NEW EXTERIOR DOORS AND WINDQEIMIC�.30 AREA CALCULATIONS Jun 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT (E) MAIN FLOOR FINISHED 1,535 S.F. (E) UPPER FLOOR FINISHED 897 S.F. TOTAL HEATED AREA 2,432 S.F. (E) DECKS & PORCHES 377 S.F. (E) GARAGE 582 S.F. REV.. 10. 6/6/2024- BUILDING COMMENTS PELLETIER(+) S C H A A R vISIun BaSt--U /-,r urlltectUi t_- 26911 98th Dr. NW, Suite B • Stanwood, WA 98292 www.pelletierschaar.com • 36o-629-5375 NO.: XXXXXX DRN: XXX CHK: XXX © 2023 PELLETIER + SCHAAR, L.L.C. 69CREGERETD DAVSTAAl ml 5/17/2024 W CU Z W 0 0 LW 0./ V Z I- U) X W b N� L.L W N BUILDING PERMIT - FIRST FLOOR PLAN & WINDOW SCHEDULE PHASING LEGEND EXISTING CONSTRUCTION TO REMAIN PROJECT NORTH ZQ,_n" SECOND FLOOR PLAN SCALE 1/4"= l'-O" 0' 4' 8' INTERIOR DOOR SCHEDULE NO. LOCATION TYPE DIMENSIONS HRDWR NOTES DOORATERIA FIRM 210 PANTRY Al 3/0 X 6/8 PKT 211 MASTER BATHROOM B1 3/0 X 6/8 SWING 212 W.I.C. Al 2/6 X 6/8 PKT 213 MASTER BATHROOM Al 2/6 X 6/8 PKT 214 REC. ROOM Cl 8/0 X 6/8 SLDR SAFETY GLASS 215 MASTER BATHROOM Al 3/0 C 6/8 PKT Al B1 M,-.��r'�17WAF.Y. ITEMS TO BE DEMOLISHED NEW CONSTRUCTION PLAN GENERAL NOTES 1. WALLS, CEILING AND FLOOR INSULATION; AND WINDOW AND DOOR GLAZING TO BE IN ACCORDANCE 2021 WSEC. SEE SHT. A0.1. 2. TEMPERED SAFETY GLAZING TO BE PROVIDED PER 2021 IRC SECTION R308.4; SEE ELEVATIONS OR WINDOW SCHEDULE FOR LOCATIONS. 3. INSTALL 110V SMOKE DETECTORS, INTERCONNECT W/ BATTERY BACKUP, PER 2021 IRC WA STATE AMENDMENTS SECTION R314; SEE PLANS FOR LOCATIONS. 4. INSTALL CARBON MONOXIDE DETECTORS PER 2021 IRC WA STATE AMENDMENTS SECTION R315; SEE FLOOR PLAN FOR LOCATIONS. 5. INSTALL WHOLE HOUSE VENTILATION FAN PER 2021 IRC WA STATE AMENDMENTS SECTION M1507.3: SYSTEM SHALL PROVIDE MIN. CFM PER TABLE M1507.3.3(1). 6. ALL EXHAUST FANS TO BE LOCATED AND SIZED PER 2021 IRC WA STATE AMENDMENTS TABLE M1507.4. rl•y_1►10Eel 69a:L1I1►Imfel 3ai�Y91►1211111591:1 3ON001N 8. PROVIDE MIN. 15" FROM CENTER OF TOILET TO ADJACENT WALL OR OTHER OBSTRUCTION AND 21" CLEARANCE DIRECTLY IN FRONT OF TOILET PER 2021 IRC SECTION R307.1. 9. 9. EXISTING CEILING, WALL OR FLOOR CAVITIES EXPOSED DURING CONSTRUCTION PROVIDED THESE CAVITIES ARE FILLED WITH INSULATION. 2x4 FRAMED WALLS SHALL BE INSULATED TO A MINIMUM OR R-15 AND 2x6 PLAN KEYNOTES 0 110V COMBINATION SMOKE & CARBON MONOXIDE DETECTOR INTERCONNECT W/ BATTERY BACKUP TYP. 0 ROOF LINE ABOVE OR WALL BELOW. CONTINUOUSLY OPERATING FAN, 60 CFM, IN ACCORDANCE WITH ANSI/AMCA 210-ANSI / ASHRAE 51. SECTION Ml505 2021 IRC AND TABLE Ml505.4.3(1) U.L. APPROVED PROPANE BURNING FIREPLACE O5 DRYER - VENT TO OUTSIDE EXHAUST TERMINATION - IN ACCORDANCE WITH IRC M 1507.3.4.4 O7 PROVIDE EMERGENCY ESCAPE OPENING IN ALL rW SLEEPING ROOMS MIN. 24" HIGH X 20" WIDTH AND 5.7 S.F. V CLEAR OPEN AREA IN ACCORDANCE WITH IRC R310.1 z 22" X 30" ATTIC ACCESS - WITH MIN. UNOBSTRUCTED W HEADROOM ABOVE HATCH OF 30" Q 0 RANGE WITH 300 CFM HOOD V J 10. 5/8" TYPE-X GWB ON ALL WALLS & CEILING AND AROUND W ALL BEAMS AND POSTS. L.L 11. SOLID CORE DOOR W/ SELF CLOSER (Il 12. TOWEL WARMER (NOT USED) z 13. 5/8" TYPE X GWB UNDER STAIR 14. ROD & SHELF V ) DOOR & WINDOW NOTES O 1. SEE SHT. A0.1 FOR 2021 WSEC REQUIREMENTS; ALL EXTERIOR DOORS AND WINDOWS SHALL COMPLY. 2. SEE FLOOR PLAN FOR SLIDING / POCKET DOOR ACTIVE z DOOR PANEL LOCATIONS AND DIRECTION PUB O 3. SEE ELEVATIONS FOR OPERABLE WINDO��� DIRECTIONS. Jun 14 2024 — 4. ALIGN WINDOW AND DOORS HEADS - TYP. CITYOFEDMONDS 5. ALL NEW EXTERIOR DOORS AND WINDOWI SVfIIpNrsERVICEs tsE A TMENT U=0.30. W REV.. 10. 6/6/2024- BUILDING COMMENTS NOTES: ALL DIMENSIONS SHOWN ± ALIGN P E L L E T I E R (+) S C H A A R O WITH EXISTING CONSTRUCTION AND TO BE VERIFIED IN THE FIELD. Vitiiun BaSt--U /-\f ui1iteCT-Uf t-- a69u 98th Dr. NW, Suite B Stanwood, WA 98292 www.peIletierschaar.c0m 36o-629-5375 AREA OF REMODEL z NO.:XXXXXX DRN:XXX CHK:XXX © 2023 PELLETIER + SCHAAR, L.L.C. b Q 6946 REGI TERED CHI ECT W DAVID . PELLETIER STATE OF WASHINGTON Al m 2 1 5/17/2024 N BUILDING PERMIT - SECOND FLOOR PLAN & DOOR SCHEDULE I - 1". 1 x"lv I � v " - I � 1 11 v . v .. - v , - k- . ---. , . - -1 WINDOW AND INFILL WALL INFILL WALLS AS REQUIRED SEE 10/A3.1 WEST ELEVATION SCALE 1/4"= l'-0" 0' 4' 8' SOUTH ELEVATION SCALE 1/4"= l'-0" 0' 4' 8' TE 0 e ; 0 MATERIALS KEY 1O HORIZONTAL HARDI SIDING - MATCH EXISING O2 2X TRIM ALL AROUND & METAL FLASHING AT HEAD TRIM TO MATCH EXISTING NEW FLUSH f""" "�� STf EXISTI CONS EXISTING CEI PATCH AND F PAINTED 1X 11\1IV1-- AROUND NEW BEAM DETAIL SCALE: 3/4" = 1'-01, E C EXISTIN PATCH E TYPICAL WALL SECTION SCALE: 3/4" = l'-0" EXISTING GUTTERS AND FASCIAS RUCTION )IDING, DS AND L FINISH TO O FILL =E NOTES RESUB Jun 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT P E L L E T I E R O S C H A A R Vision Based Architecture 26911 98th Dr. NW, Suite B Stanwood, WA 98292 www.pelletierschaar.com 36o-629-5375 NO.:XXXXXX DRN:XXX CHK:XXX © 2023 PELLETIER + SCHAAR, L.L.C. 6946 DAMD R-PELLETIER STATE OF WASHINGTON A3ml 5/17/2024 W U Z W C� NW ry V Z VJ X W O VJ Z O ry W J L.L O ry W Z O 0 ry W_ 0 N BUILDING PERMIT - ELEVATIONS