Loading...
REVIEWED BLD RESUB1 BLD2024-0685+Structural Calcs+6.14.2024_10.07.04_AM+4322995RESUB BLD2024-0685 Jun 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ...........................................L REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT STRUCTURAL CALCULATIONS Project: Address: Project No.: Date: Izquierdo Residence Remodel 821 Bell St Edmonds, WA 98020 24156 June 12, 2024 PERMIT SUBMITTAL Client: JOSE IZQUIERDO & MADELINE MERCIER Contents: Calculations 2-9 13/2024 1412 Beach Drive NE Unit A I Tacoma WA, WA 198422 253.533.0835 1 tel S t r u c t u r a l W o r k s, P L L C These enclosed documents are to be used in conjunction with the plans referenced on the cover. It is essential that the contractor study the engineering requirements and required changes to the architectural plan prior to start of work. Changes may include additional foundation or footings, beam size changes, siding changes, etc. Scope of Engineering: Engineering analyses and design to resist lateral and gravity loads in accordance with the 2021 IBC have been performed and incorporated into stamped "S" sheets. All analyses and calculations are included in this engineering report. Engineering assumptions are listed below. If these conditions are not present at the site, these calculations are void and Structural Works, PLLC must be contacted immediately. Loading Criteria - Building Code - Seismic Design Category - Sds - Response Mod Factor - Site Class - Basic Wind Speed Live Loads U.N.O. - Uninhabitable attics without storage - Uninhabitable attics with storage - Habitable attics and sleeping areas - Decks - All other areas Dead Loads U.N.O. - Roof with composition roofing - Floor Snow Loads U.N.O. - Snow Soils Criteria - Soils consultant - Soils Report # - Bearing Pressure Required - Min Frost Depth 2021 International Building Code D 1.029 6.5 D 110 MPH, Exposure B 10 psf 20 psf 30 psf 60 psf 40 psf 15 psf 10 psf 25 psf None None 1500 psf (min required - Assumed) 12" Structural Works PLLC 1412 Beach Drive NE #A Tacoma, WA 98422 (253) 533-0835 ATC Hazards by Location A This is a beta release of the new ATC Hazards by Location website. Please contact us with feedback. 6 The ATC Hazards by Location website will not be updated to support ASCE 7-22. Find out why, 8TCHazards by Location Search Information Address: 821 Bell St, Edmonds, WA 98020 Coordinates: 47.8115173,-122.3682456 Elevation: 197 ft Timestamp: 2024-05-06T18:09:56.495Z ' Hazard Type: Seismic Reference Document: ASCE7-16 Risk Category: II Site Class: D-default Basic Parameters Name Value Description SS 1.287 MCER ground motion (period=0.2s) S1 0.453 MCER ground motion (period=1.0s) SMS 1.544 Site -modified spectral acceleration value SM1 * null Site -modified spectral acceleration value SDS 1.029 Numeric seismic design value at 0.2s SA SDl * null Numeric seismic design value at 1.0s SA * See Section 11.4.8 Additional Information Name Value Description SDC * null Seismic design category Fa 1.2 Site amplification factor at 0.2s Fv * null Site amplification factor at 1.0s CRS 0.91 Coefficient of risk (0.2s) CRt 0.895 Coefficient of risk (1.0s) PGA 0.548 MCER peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.657 Site modified peak ground acceleration TL 6 Long -period transition period (s) SsRT 1.287 Probabilistic risk -targeted ground motion (0.2s) SsUH 1.414 Factored uniform -hazard spectral acceleration (2 % probability of exceedance in 50 years) SsD 2.209 Factored deterministic acceleration value (0.2s) S1 RT 0.453 Probabilistic risk -targeted ground motion (1.0s) S1 UH 0.506 Factored uniform -hazard spectral acceleration (2 % probability of exoeedance in 50 years) S1 D 0.9 Factored deterministic acceleration value (1.0s) PGAd 0.779 Factored deterministic acceleration value (PGA) * See Section 11.4.8 Lake 1 The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Please note that the ATC Hazards by Location website will not be updated to support ASCE 7-22. Find out why. Disclaimer 6.05.2024 21:09 ATC Hazards by Location Hazard loads are provided by the U.S. Geological Survey Seismic Design Web Services. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liabilityfor its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the report. 6.05.2024 21:08 ATC Hazards by Location A This is a beta release of the new ATC Hazards by Location website. Please contact us with feedback. 8 The ATC Hazards by Location website will not be updated to support ASCE 7-22. Find out why, ATCHazards by Location Search Information Address: 821 Bell St, Edmonds, WA98020 Coordinates: 47.8115173,-122.3682456 Elevation: 197 ft Timestam p: 2024-05-06T18:08:15.324Z Hazard Type: Wind ASCE 7-16 MRI10-Year ______________ 67 mph MRI25-Year 73 mph MRI50-Year 78 mph MRI100-Year ___ 83 mph Risk Category I 92 mph Risk Categoryll _______________________________ 97 mph Risk Category III ----- 104 mph Risk Category IV 108 mph ASCE 7-10 MRI 10-Year 72 mph MRI25-Year 79 mph MRI50-Year 85 mph MRI100-Year 91 mph Risk Category 1 100 mph Risk Categoryll ______ 110 mph Risk Category III -IV ________________ 115 mph )rth Creek sza szz Woodinville ASCE 7-05 ASCE 7-05 Wind Speed 85 mph The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Please note that the ATC Hazards by Location website will not be updated to support ASCE 7-22. Find out why. Disclaimer Hazard loads are interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer. Per ASCE 7, islands and coastal areas outside the last contour should use the last wind speed contour of the coastal area — in some cases, this website will extrapolate past the last wind speed contour and therefore, provide a wind speed that is slightly higher. NOTE For queries near wind-borne debris region boundaries, the resulting determination is sensitive to rounding which may affect whether or not it is considered to be within a wind-borne debris region. Mountainous terrain, gorges, ocean promontories, and special wind regions shall be examined for unusual wind conditions While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the report. FO R T E W E B' JOB SUMMARY REPORT 24156 Level Member Name Results (Max UTIL o/o) Current Solution Comments HDR-1 Passed (68% R) 1 piece(s) 5 1/2" x 10 1/2" 24F-V4 DF Glulam FB-1 Passed (96% R) 1 piece(s) 5 1/2" x 15" 24F-V4 DF Glulam RHDR-1 Passed (52% R) 1 piece(s) 4 x 12 DF No.2 A 5/6/2024 6:16:22 PM UTC ForteWEB v3.7 Weyerhaeuser File Name: 24156 Page 1 / 4 aFORTEWEB' Level, HDR-1 1 piece(s) 5 1/2" x 10 1/2" 24F-V4 DF Glulam PASSED r Id Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 3643 @ 0 5363 (1.50") Passed (68%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 3022 @ 1' 11733 Passed (26%) 1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Pos Moment (Ft-Ibs) 4132 @ 2' 7 1/4" 23244 Passed (18%) 1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in) 0.019 @ 3' 5/16" 0.208 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.031 @ 3' 1/4" 0.313 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 6' 3". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Member Length : 6' 3" System: Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Supports= Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Roof Live Snow Factored 1 - Trimmer - SPF 1.50" 1.50" 1.50" 1503 1125 1383 1729 3643 None 2 - Trimmer - SPF 1.50" 1.50" 1.50" 891 1125 567 709 2266 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 6' 3" o/c Bottom Edge (Lu) 6' 3" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads mm Location Tributary Width Dead (0.90) Floor Live (1.00) Roof Live (1.25) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 6' 3" N/A 14.0 1 - Uniform (PSF) 0 to 6' 3" 9' 15.0 40.0 - - Floor Loads 2 - Point (lb) 1' N/A 900 - 1200 1500 3 - Uniform (PSF) 0 to 6' 3" 6' 15.0 20.0 25.0 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by UG 5/6/2024 6:16:22 PM UTC ForteWEB v3.7, Engine: V8.4.0.40, Data: V8.1.5.0 Weyerhaeuser File Name: 24156 Page 2/4 aFORTEWEB' Level, F13-1 1 piece(s) 5 1/2" x 15" 24F-V4 DF Glulam PASSED 0 a o Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 5072 @ 2" 5259 (2.25") Passed (96%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 4278 @ 1' 6 1/2" 16761 Passed (26%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 22983 @ 9' 3 1/2" 46715 Passed (49%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.224 @ 9' 3 1/2" 0.456 Passed (L/977) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.495 @ 9' 3 1/2" 0.913 Passed (L/443) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/480) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume/size factor of 0.98 that was calculated using length L = 18' 3". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. 0 Member Length : 18' 4 1/2" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Roof Live Snow Factored 1 - Stud wall -SPF 3.50" 2.25" 2.17" 2804 372 1858 2323 5127 1 1/4" Rim Board 2 - Stud wall - SPF 3.50" 2.25" 2.17" 2804 372 1858 2323 5127 1 1/4" Rim Board • Rim t3oaro is assumed to carry all loads applied directly above it, bypassing the member oeing designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 18' 5" o/c Bottom Edge (Lu) 18' S" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Tributary Width Dead (0.90) Floor Live (1.00) Roof Live (1.25) Snow (1.15) Comments 0 - Self Weight (PLF) 1 1/4" to 18' 5 3/4" N/A 20.0 1 - Uniform (PSF) 0 to 18' 7" (Front) 1' 12.0 40.0 - - Floor Load 2 - Uniform (PSF) 0 to 18' 7" (Front) 10' 15.0 - 20.0 25.0 Roof Load 3 - Uniform (PLF) 0 to 18' 7" (Front) N/A 120.0 - - Wall Load Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by UG 5/6/2024 6:16:22 PM UTC ForteWEB 0.7, Engine: V8.4.0.40, Data: V8.1.5.0 Weyerhaeuser File Name: 24156 Page 3/4 aFORTEWEB' Level, RHDR-1 1 piece(s) 4 x 12 DF No.2 PASSED 0 4 0 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Id Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1691 @ 0 3281 (1.50") Passed (52%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1256 @ 1' 3/4" 5434 Passed (23%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 3488 @ 4' 1 1/2" 7004 Passed (50%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.039 @ 4' 1 1/2" 0.275 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.064 @ 4' 1 1/2" 0.412 Passed (L/999+) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Factored 1 - Trimmer - SPF 1.50" 1.50" 1.50" 660 825 1031 1691 None 2 - Trimmer - SPF 1.50" 1.50" 1.50" 660 825 1031 1691 None Lateral Bracing Bracing Intervals comments Top Edge (Lu) 8' 3" o/c Bottom Edge (Lu) 8' 3" o/c -Maximum allowable bracing intervals based on applied load. Dead Roof Live Snow Vertical Loads Location Tributary (0.90) (1.25) (1.15) Comments Width 0 - Self Weight (PLF) 0 to 8' 3" N/A 10.0 1 1 -- 1 - Uniform (PSF) 0 to 8' 3" 10' 15.0 1 20.0 1 25.0 Default Load 0 Member Length : 8' 3" System: Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Weyerhaeuser Notes Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to Nww.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by UG 5/6/2024 6:16:22 PM UTC ForteWEB v3.7, Engine: V8.4.0.40, Data: V8.1.5.0 Weyerhaeuser File Name: 24156 Page 4/4