REVIEWED BLD RESUB1 BLD2024-0685+Structural Plans+6.14.2024_10.07.04_AM+4322994GENERAL NOTES ANY DISCREPANCIES FOUND AMONG THE DRAWINGS, THE SPECIFICATIONS, THESE GENERAL NOTES AND THE SITE CONDITIONS SHALL BE REPORTED TO THE ARCHITECT, WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING. ANY WORK DONE BY THE GENERAL CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE GENERAL CONTRACTOR'S RISK. THE GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE DIMENSIONS AMONG ALL DRAWINGS PRIOR TO PROCEEDING WITH ANY WORK OR FABRICATION. THE STRUCTURE HAS BEEN DESIGNED TO RESIST CODE SPECIFIED VERTICAL AND LATERAL FORCES AFTER THE CONSTRUCTION OF ALL STRUCTURAL ELEMENTS HAS BEEN COMPLETED. STABILITY OF THE STRUCTURE PRIOR TO COMPLETION IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THIS RESPONSIBILITY INCLUDES BUT IS NOT LIMITED TO JOB SITE SAFETY; ERECTION MEANS, METHODS, AND SEQUENCES; TEMPORARY SHORING, FORMWORK, BRACING; USE OF EQUIPMENT AND CONSTRUCTION PROCEDURES. CONSTRUCTION OBSERVATION BY THE STRUCTURAL ENGINEER IS FOR GENERAL CONFORMANCE WITH DESIGN ASPECTS ONLY AND IS NOT INTENDED IN ANY WAY TO REVIEW THE CONTRACTOR'S CONSTRUCTION PROCEDURES. STANDARDS ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2021 INTERNATIONAL RESIDENTIAL CODE (IRC) AS AMENDED AND ADOPTED BY THE LOCAL BUILDING OFFICIAL OR APPLICABLE JURISDICTION. APPLICABLE STRUCTURAL PROVISIONS: • 2021 INTERNATIONAL BUILDING CODE (IBC) DESIGN CRITERIA VERTICAL LOADS AREA DESIGN DEAD LOAD LIVE LOAD ROOF 15 PSF 25 PSF (SNOW) OTHER ROOMS FLOORS 15 PSF 40 PSF (2) STAIRS ACTUAL 100 PSF (OR 300# PER TREAD) DECKS ACTUAL 60 PSF (1) LIVE LOAD REDUCTION NOT PERMITTED EXCEPT AS NOTED IN IBC SECTION 1607.10. (2) 30 PSF FOR SLEEPING AREAS SNOW: (MINIMUM ROOF SNOW LOAD = 25 PSF) Pg = 25 PSF =GROUND SNOW LOAD Pf = 0.7CeCt IsPg =FLAT ROOF SNOW LOAD Ps = CsPf =SLOPED ROOF SNOW LOAD Is = 1.0 Ce = 1.0, Ct = 1.0, Cs =VARIES LATERAL FORCES THE BUILDING MEETS THE CRITERIA TO USE THE "EQUIVALENT LATERAL FORCE PROCEDURE" PER ASCE 7-16. WIND: :� - EXPOSURE CATEGORY = B - BASIC WIND SPEED, (3 SEC. GUST), Vu�T = 110 MPH - WIND IMPORTANCE FACTOR, Iw = 1.0 - OCCUPANCY BUILDING CATEGORY PER TABLE 1-1 = II - INTERNAL PRESSURE COEFFICIENT (ENCLOSED) _ ± 0.18 - TOPOGRAPHIC FACTOR KZT = 1.00 SEISMIC: SEISMIC IMPORTANCE FACTORS e = 1.0 RISK CATEGORY OF BUILDING PER TABLE 1.5-1 = II SPECTRAL RESPONSE ACCELERATIONS Ss = 1.287 & S1 = 0.453 SITE CLASS PER TABLE 20.3-1 = D DESIGN SPECTRAL RESPONSE ACCELERATIONS Sds = 1.029 SEISMIC DESIGN CATEGORY = D ANALYSIS PROCEDURE USED =SIMPLIFIED LATERAL FORCE ANALYSIS RESPONSE MODIFICATION FACTOR PER TABLE 12.2-1, R = 6.5 FOUNDATION DESIGN CRITERIA SOIL BEARING PRESSURE: 1500 PSF (ASSUMED)* ACTIVE PRESSURE -RESTRAINED: 55 PCF +14H SEISMIC SURCHARGE (ASSUMED) ACTIVE PRESSURE -UNRESTRAINED: 35 PCF +6H SEISMIC SURCHARGE (ASSUMED) PASSIVE RESISTANCE: 200 PCF (INCLUDES F.O.S. >_ 1.5) (ASSUMED) COEFFICIENT OF FRICTION:.35 (INCLUDES F.O.S. >_ 1.5) (ASSUMED) ALL FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH OR "STRUCTURAL BACKFILL". NATIVE EARTH BEARING SHALL BE SURFACE COMPACTED. AREAS OVER -EXCAVATED SHALL BE BACKFILLED WITH LEAN CONCRETE (F'c= 2000 PSI) OR "STRUCTURAL BACKFILL". AREAS DESIGNATED "STRUCTURAL BACKFILL" SHALL BE FILLED WITH APPROVED WELL -GRADED BANKRUN MATERIAL. MAXIMUM SIZE OF ROCK 4". FROZEN SOIL, ORGANIC MATERIAL AND DELETERIOUS MATTER NOT ALLOWED. COMPACT TO AT LEAST 95% OF ITS MAXIMUM DENSITY AS DETERMINED BY ASTM D1557. PROVIDE DRAINAGE AND DEWATERING AROUND ALL WORK TO AVOID WATER -SOFTENED FOOTINGS. FREE DRAINING BACKFILL MATERIAL FOR RETAINING &BASEMENT WALLS A CLEAN, FREE DRAINING, WELL GRADED GRANULAR MATERIAL CONFORMING TO ASTM D2487 GW OR SW WHOSE MAXIMUM PARTICLE SIZE DOES NOT EXCEED 3/4" AND WHOSE FINES CONTENT (MATERIAL PASSING THE NO. 200 SIEVE) DOES NOT EXCEED 5%, PASSING U.S. NO. 200 SIEVE WITH A MAXIMUM DUST RATIO PASSING U.S. NO. 40 SIEVE CONCRETE SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE SPECIFIED BELOW, SHALL BE SUBMITTED FOR APPROVAL A MINIMUM OF 2 WEEKS PRIOR TO BID, ALONG WITH CALCULATIONS THAT ARE PREPARED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER (LICENSED IN THE STATE IN WHICH THE PROJECT OCCURS) DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING EQUIVALENT PERFORMANCE VALUES (MINIMUM) OF THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE AND/OR STANDARDS) AS REQUIRED BY THE BUILDING CODE. CONCRETE ANCHORS: - ADHESIVE ANCHORS: HILTI HIT-HY 200 (ICC-ESR-3187) *CONCRETE SHALL BE A MINIMUM OF 21 DAYS OLD AT TIME OF INSTALLATION. *CONCRETE SHALL BE IN THE TEMPERATURE RANGE AS REQUIRED BY THE CONCRETE MANUFACTURER. *HOLE SHALL BY HAMMER -DRILLED ONLY. *HOLE SHALL BE DRY AT TIME OF INSTALLATION. *INSTALLER OF HORIZONTAL OR UPWARDLY INCLINED (ANY POSITION EXCEPT DIRECTLY DOWNWARD) ANCHORS SHALL ALSO BE CERTIFIED BY THE ACl/CRSI ADHESIVE ANCHOR INSTALLER CERTIFICATION PROGRAM. - EXPANSION ANCHORS: KWIKBOLT TZ (ICC ESR-1917) BY HILTI, INC. OR STRONG -BOLT 2 (ICC ESR-3037) BY SIMPSON STRONG TIE, INC. - SCREW ANCHORS: KWIK HUS-EZ (ICC ESR-3027) BY HILTI, INC. OR TITEN HD (ICC ESR-2713) BY SIMPSON STRONG TIE, INC. STRUCTURAL STEEL = 2/3 MAX. DETAILING, FABRICATION AND ERECTION CONCRETE: MODERATE WEATHERING POTENTIAL SHALL BE MADE WITH PORTLAND CEMENT SHALL BE MADE WITH PORTLAND CEMENT ASTM C-150 TYPE II OR TYPE I, COARSE AND FINE AGGREGATE ASTM C-33, WATER CLEAN AND POTABLE AND SHALL BE READY MIXED PER ASTM C-94. NO ALUMINUM (CONDUIT, MISCELLANEOUS ITEMS, ETC.) SHALL BE EMBEDDED IN ANY CONCRETE. COORDINATE FORMWORK AND FINISH TYPES ACCEPTABLE TO THE OWNER. MAX. MIN. AGGREGATE ITEM DESIGN f'c (PSI) W/C FLYASH GRADING NOTES (AT 28 DAYS U.N.O.) RATIO O(PCY) G ASTM AASHTO SLAB ON GRADE 2500 0.45 100 57 OR 67 1 FOUNDATIONS - UNO 2500 0.50 -- 57 OR 67 STEM WALLS 2500 0.45 100 57 OR 67 CONCRETE MIX NOTES: 1. FIBROUS CONCRETE REINFORCEMENT SHALL BE "FIBERMESH" MANUFACTURED BY PROPEX CONCRETE SYSTEMS OR PRE -APPROVED EQUAL. DOSAGE SHALL FOLLOW MANUFACTURER'S RECOMMENDATION BUT NOT LESS THAN 1.5 LB/CU. YD. 2. PROVIDE 3000 PSI AT 28 DAYS MINIMUM FOR DURABILITY AT BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS, PORCHES, CARPORT SLABS AND STEPS EXPOSED TO THE WEATHER AND FOR ALL GARAGE FLOOR SLABS. CONCRETE SHALL BE AIR ENTRAINED CONFORMING TO ASTM C-260. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL NOT BE LESS THAN 5% OR MORE THAN 7%. PLACE CONCRETE: PER ACI 304 AND CONFORM TO ACI 305 AND 306 FOR HOT AND COLD WEATHER PLACEMENT AND CURING PROTECTION. USE INTERIOR MECHANICAL VIBRATORS WITH 7000 RPM MINIMUM FREQUENCY. DO NOT OVER -VIBRATE. CONCRETE SHALL BE POURED MONOLITHICALLY BETWEEN CONSTRUCTION OR EXPANSION JOINTS. PROTECT ALL FRESHLY PLACED CONCRETE FROM PREMATURE DRYING, EXCESSIVE HOT OR COLD TEMPERATURE FOR SEVEN DAYS AFTER POURING. C�RC�l1T NON -SHRINK GROUT: GROUT SHALL CONFORM TO CRD-C621. F'c = 5000 PSI IN 28 DAYS. FILL OR PACK ENTIRE SPACE UNDER PLATES OR SHAPES. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION, INSTALLATION, AND CURING. REINFORCING STEEL REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60. DETAIL, FABRICATE AND PLACE PER ACI 315 AND ACI 378. LAP SPLICES SHALL BE 48 BAR DIAMETERS UNLESS NOTED OTHERWISE. PROVIDE CORNER BARS AT ALL HORIZONTAL BARS IN FOOTINGS AND WALLS. WELDED WIRE REINFORCEMENT SHALL CONFORM TO A185. LAP ONE FULL MESH ON SIDES AND ENDS BUT NOT LESS THAN 8 INCHES. PLACE AT MID -DEPTH OF SLAB OR AS SHOWN. POST -INSTALLED ANCHORS POST -INSTALLED ANCHORS: SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE STRUCTURAL ENGINEER PRIOR TO INSTALLING POST -INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST -IN -PLACE ANCHORS. CARE SHALL BE TAKEN IN PLACING POST -INSTALLED ANCHORS TO AVOID CONFLICTS WITH REBAR. INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. INSTALLER SHALL BE QUALIFIED AND TRAINED BY THE MANUFACTURER. HOLES SHALL BE HAMMER DRILLED ONLY (ROTARY DRILLED ONLY AT UNREINFORCED MASONRY - NO HAMMER TOOLS). ALL WORKMANSHIP SHALL CONFORM TO THE AISC MANUAL OF STEEL CONSTRUCTION, 14TH EDITION. MATERIAL PROPERTIES WIDE FLANGE SECTIONS: ASTM A992 (Fy = 50 KSI) OTHER SHAPES AND PLATES: ASTM A36 (Fy = 36 KSI) TYP. U.N.O.; ASTM A572 (Fy = 50 KSI) WHERE INDICATED HOLLOW STRUCTURAL SECTIONS: RECTANGULAR &SQUARE -ASTM A500 GRADE B (Fy = 46 KSI) ROUND -ASTM A500 GRADE B (Fy = 42 KSI) STRUCTURAL STEEL PIPES: ASTM A53, GRADE B, TYPE E OR S (Fy = 35 KSI) MACHINE BOLTS (M.B.): ASTM A307, GRADE A ANCHOR BOLTS (A.B.): ASTM F1554, GRADE 55, UNLESS OTHERWISE NOTED, ASTM F1554, GRADE 105 WHERE INDICATED. WELDING STRUCTURAL STEEL: WELD IN ACCORDANCE WITH "STRUCTURAL WELDING CODE" AWS D1.1. CERTIFICATION :ALL WELDING SHALL BE PERFORMED BY WABO/AWS CERTIFIED WELDERS. WELDERS SHALL BE PREQUALIFIED FOR EACH POSITION AND WELD TYPE WHICH THE WELDER WILL BE PERFORMING. ELECTRODES: USE E70 ELECTRODES. GENERAL REQUIREMENTS ADHESIVE ANCHOR RODS: ASTM F1554, GRADE 36 UNLESS NOTED OTHERWISE. FINISH :STRUCTURAL STEEL SHALL BE PRIMER PAINTED, UNLESS NOTED OTHERWISE. WHERE STRUCTURAL STEEL IS NOTED TO BE GALVANIZED, IT SHALL BE HOT -DIP GALVANIZED IN ACCORDANCE WITH ASTM A123, A384, AN D A385. STRUCTURAL DRAWING INDEX SHEET NUMBER SHEET DESCRIPTION S0.0 GENERAL NOTES S0.1 GENERAL NOTES S1.0 FOUNDATION PLAN S1.1 FIRST FLOOR FRAMING PLAN S1.2 SECOND FLOOR FRAMING PLAN S2.0 ROOF FRAMING PLAN S3.0 SHEARWALL SCHEDULE AND HOEDOWN LAYOUTS S3.1 SHEARWALL SCHEDULE AND HOEDOWN LAYOUT S4.0 STRUCTURAL FRAMING DETAILS Grand Total: 9 L■ � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT 7����������������������������������������������f� U Cn � ~ w O z Y J O I..L Z N Q � �� �rn � � U���� U � p a c��� � m ��cn H � C1� � � N W N i 0 N M �? �~} PAW W � E Q �' o �� z ��� @� `�''� `�c�� d,�s � �w � i 440 U w 0 w J H H J W 0 O W W U Z W 0 W W 0 o N W °o rn � �� � N Jo J W mo � °No �w W O Z J Q W Z rW^, V H W H W BLD2024-0685 N Q � O o Q O � N RES U B SHEET Jun 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ■ CARPENTRY: NAILS: CONNECTION DESIGNS ARE BASED ON "COMMON WIRE" NAILS WITH THE FOLLOWING PROPERTIES: PENNYWEIGHT DIAMETER (INCHES) LENGTH (INCHES) TRACKER** COLOR CODED NAILS 8d 0.131 2-1/2 BLUE 10d 0.148 3 PURPLE 16d 0.162 3-1/2 ORANGE 20d 0.192 4 - FOR DIAPHRAGM OR SHEAR WALL NAILING THE FOLLOWING FASTENER TYPES MAY BE USED AT EQUIVALENT SPACING TO THAT SPECIFIED ON PLANS: FASTENER TYPE DIAMETE LENGTH EQUIVALENT SPACIN TRACKER** COLOR (INCHES) (INCHES) (INCHES) CODED NAILS 8d COMMON WIRE 0.131 2-1/2 6 4 3 BLUE 8d "DIPPED GALV. BOX" 0.131 2-1/2 6 4 3 - 8d "SHINY BOX" 0.113 2-1/2 4-1/2 3 2-1/2 YELLOW 12 GA. STAPLES 0.1055 1-7/8* 6 5-1 /2 4 - 14 GA. STAPLES 0.080 1-1 /2* 6 4 3 - 15 GA STAPLES 0.072 1-1 /2* 5 3 2-1 /2 - 10d COMMON WIRE 0.148 3 6 4 3 PURPLE 10d "HOT DIPPED GALV. BOX" 0.148 3 6 4 3 - 10d "SHINY BOX" 0.128 3 4-1/2 3 2-1/4 WHITE *BASED ON 15/32" PLYWOOD OR OSB. **REFERENCE TO COLOR CODED NAILS PER TRACKERS SYSTEM. WOOD SHEATHING (STRUCTURAL): SHEATHING SHALL BE PLYWOOD OR ORIENTED STRAND BOARD. PLYWOOD SHEATHING SHALL BE 5-PLY MINIMUM WHERE INDICATED AS 3/4" OR THICKER. WOOD SHEATHING SHALL BE "STRUCTURAL I" CONFORMING TO PS1-09 AND/OR PS2-10. ALL PANELS SHALL BEAR THE STAMP OF AN APPROVED GRADING AGENCY. SPAN RATING SHALL BE PROVIDED AS FOLLOWS: ROOF FRAMING AT 32"O.C. (48/24); ROOF FRAMING AT 24"O.C. (32/16); WALLS (32/16); FLOORS (48/24) ALL WOOD SHEATHED WALLS SHALL BE BLOCKED AT ALL PANEL EDGES UNLESS NOTED OTHERWISE. GLUE -LAMINATED MEMBERS: CONFORM TO ANSI/AITC A190.1. MEMBERS SHALL BE COMBINATION 24F-V4 DOUGLAS FIR (DF) FOR SIMPLE SPANS AND 24F-V8 DF FOR CANTILEVERED SPANS (Fb=2400 PSI, Fv=265 PSI, E_ 1.8X10^6 PSI) AND DF COMBINATION 2 FOR COLUMNS. ARCHITECTURAL APPEARANCE GRADE WHERE EXPOSED TO VIEW; INDUSTRIAL APPEARANCE GRADE WHERE NOT EXPOSED TO VIEW. ALL MEMBER TO HAVE EXTERIOR GLUE AND HAVE AITC OR APA-EWS STAMP. CAMBER AS SHOWN ON STRUCTURAL DRAWINGS. FRAMING LUMBER: STANDARDS. EACH PIECE SHALL BEAR THE GRADE TRADEMARK OF THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB), WESTERN WOOD PRODUCTS ASSOCIATION (WWPA), OR OTHER AGENCY ACCREDITED BY THE AMERICAN LUMBER STANDARD COMMITTEE (ALSC) TO GRADE UNDER ALSC CERTIFIED GRADING RULES. SPECIES AND GRADE (BASE DESIGN VALUE) 1. 6x BEAMS AND HEADERS. "DOUG FIR -LARCH" NO. 1 (Fb=1350 PSI, Fv=170 PSI) 2. 2x TO 4x JOISTS, PURLINS AND HEADERS. "DOUG FIR -LARCH" NO. 2 (Fb=900 PSI, Fv=180 PSI) OR "HEM -FIR" NO. 1 (Fb=975 PSI, Fv=150 PSI) 3. 6x POSTS AND COLUMNS. "DOUG FIR -LARCH" NO. 1 (Fc=1000 PSI) 4. EXTERIOR STUDS, INTERIOR BEARING WALLS AND 4x COLUMNS. "DOUG FIR -LARCH" NO. 2 (Fb= 900 PSI, Fc= 1350 PSI) OR "HEM -FIR" NO. 1 (Fb=975 PSI, Fc=1350 PSI). 5. INTERIOR NON -BEARING STUD WALLS. "DOUG FIR -LARCH" NO. 2 (Fb=900 PSI. Fc=1350 PSI) OR "HEM -FIR" NO. 1 (Fb=975 PSI, Fc=1350 PSI) STRUCTURAL COMPOSITE LUMBER (SCL): SHALL BE MANUFACTURED BY WEYERHOUSER, OR PRE -APPROVED EQUAL IN ACCORDANCE WITH APPROVED SHOP AND INSTALLATION DRAWINGS CONFORMING TO A CURRENT ICC EVALUATION REPORT. MIINIMUM DESIGN VALUES: 1. 2x LVL: Fb = 1700 PSI, Fv = 285 PSI, E = 1300 KSI 2. 1-3/4" LVL: Fb = 2600 PSI, Fv = 285 PSI, E = 1800 KSI 3. 3-1/2" LVL: Fb = 2900 PSI, Fv = 285 PSI, E = 2000 KSI 4. 5-1/4" LVL: Fb = 2900 PSI, Fv = 285 PSI, E = 2000 KSI 5. RIMBOARD:APA/EWS PERFORMANCE RATED RIM (PRR-401) 1-1/4" MINIMUM THICKNESS PRESERVATIVE TREATED WOOD REQUIREMENTS: TREATMENTS OTHER THAN THOSE LISTED BELOW ARE NOT PERMITTED. APPLICATION SPECIFIED MATERIAL PRESERVATIVE CONNECTORS & TREATMENT (1) FASTENERS (2)(3) FOUNDATION SILL PLATES, 2x, 4x, 6x (FIR), OR SBX GALV (G60) � TOP PLATES &LEDGERS GLULAM (SP) � p ON CONCRETE OR ACQ, CBA, CA GALV (G185) MASONRY WALLS (4) � p FRAMING, DECKING, 2x, & 4x (FIR) ACQ, CBA, CA GALV (G185) � X POSTS &LEDGERS 2x, & 4x (CEDAR) NONE GALV (G90) w w � BEAMS &COLUMNS 6x (FIR), OR GLULAM (SP) ACQ, CBA, CA GALV (G185) 6x OR GLULAM (CEDAR) NONE GALV (G90) 1. CCA: CHROMATED COPPER ARSENATE NOT PERMITTED SBX: DOT SODIUM BORATE ACQ: ALKALINE COPPER QUAT CBA & CA: COPPER AZOLE FIR: DOUG-FIR OR HEM -FIR SP: SOUTHERN PINE GENERAL REQUIREMENTS: PROVIDE MINIMUM NAILING PER IBC TABLE 2304.10.1 OR MORE, AS OTHERWISE SHOWN. STAGGER ALL NAILING TO PREVENT SPLITTING OF WOOD MEMBERS. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESERVATIVE TREATED WITH THE EXCEPTION OF INTERIOR CONCRETE TOPPINGS ON WOOD FLOOR SYSTEMS. HOLES AND CUTS IN 3x OR 4x PLATES SHOULD BE TREATED WITH A 9% SOLUTION OF COPPER NAPHTHENATE. BOLT HOLES IN WOOD MEMBERS SHALL BE A MINIMUM OF 1/32" TO A MAXIMUM OF 1/16" LARGER THAN THE BOLT DIAMETER. PROVIDE CUT WASHERS WHERE BOLT HEADS, NUTS AND LAG SCREW HEADS BEAR ON WOOD. PROVIDE A MINIMUM 3"x3"x0.229" PLATE WASHER ON ALL ANCHOR BOLTS WHICH CONNECT MUD SILLS TO FOUNDATION. DO NOT NOTCH OR DRILL STRUCTURAL MEMBERS, EXCEPT AS ALLOWED BY IBC SECTIONS 2308.4.2.4, 2308.5.9, 2308.5.10 AND 2308.7.4 OR AS RESTRICTED BY PLANS OR DETAILS, OR AS APPROVED PRIOR TO INSTALLATION. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS IN THESE GENERAL NOTES FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. FASTENING SCHEDULE FOR WOOD STRUCTURAL MEMBERS (UNLESS NOTED OTHERWISE ON PLANS) ITEM TYPE. CONNECTION RAFTER OR TRUSS TO TOP PLATE TOENAIL & CONNECTOR (3) 16d H2.5 48" O.C. CEILING JOIST TO TOP PLATE TOENAIL (3) 8d CEILING JOIST TO PARALLEL RAFTER FACE NAIL (3) 16d CEILING JOIST: LAP OVER PARTITION FACE NAIL (3) 16d COLLAR TIE FACE NAIL (3) 16d BLOCKING TO RAFTER TOENAIL (3) 8d RIM BOARD TO RAFTER END NAIL (2) 16d TOP PLATE TO TOP PLATE FACE NAIL (2) 16d @ 12" O.C. TOP PLATE AT INTERSECTIONS FACE NAIL (4) 16d TOP PLATE LAP FACE NAIL (8) 16d STUD TO STUD FACE NAIL (2) 16d @ 24" O.C. HEADER TO HEADER FACE NAIL 16d @ 16" O.C. EA. EDGE TOP OR BOTTOM PLATE TO STUD END NAIL (2) 16d STUD TO SOLE PLATE TOE NAIL END NAIL (4) 8d (2) 16d BOTTOM PLATE TO FLOOR JOIST AT BRACED PANEL TOE NAIL FACE NAIL 16d @ 16" O.C. (3) 16d @ 16" O.C. JOISTS TO TOP PLATE, SILL OR GIRDER TOE NAIL (4) 8d BRIDGING TO JOIST TOE NAIL (2) 8d BLOCKING TO JOISTS TOE NAIL (3) 8d BLOCKING TO TOP PLATE TOE NAIL (3) 8d RIM JOIST TO JOIST FACE NAIL (3) 16d RIM JOIST TO SILL OR TOP PLATE CONNECTOR A35 @ 24" O.C. CONTINUOUS HEADER TO STUD CONNECTOR A35 BUILT -CORNER STUDS FACE NAIL 16d @ 24" O.C. BUILT-UP BEAMS (PER LAYER) FACE NAIL 16d @ 16" O.C. EA. EDGE RAFTERS TO RIDGE BOARD TOE NAIL FACE NAIL (4) 16d (3) 16d RAFTERS TO HIP TOE NAIL FACE NAIL (4) 16d 3 16d FRAMING CONNECTORS: SHALL HAVE ICC APPROVAL AND BE MANUFACTURED BY SIMPSON STRONG -TIE COMPANY, SAN LEANDRO, CA., OR PRE -APPROVED EQUAL. PROVIDE MAXIMUM SIZE AND QUANTITY OF NAILS OR BOLTS PER MANUFACTURER, EXCEPT AS NOTED OTHERWISE. PROVIDE LEAD HOLES AS REQUIRED TO PREVENT SPLITTING OF WOOD MEMBERS. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS IN THESE GENERAL NOTES FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. LAG SCREWS: SHALL CONFORM TO ANSI/ASME STANDARD B18.2.1. LAG SCREWS SHALL BE OF A DIAMETER INDICATED ON DRAWINGS WITH A MINIMUM OF 8x DIA. EMBEDMENT IN SUPPORTING MEMBER UNLESS NOTED OTHERWISE. CLEARANCE HOLE FOR THE SHANK SHALL BE THE SAME DIAMETER AS THE SHANK AND THE SAME DEPTH OF PENETRATION AS THE UNTHREADED PORTION OF THE SHANK. THE LEAD HOLE FOR THE THREADED PORTION SHALL HAVE A DIAMETER EQUAL TO 60 TO 75 PERCENT OF THE SHANK DIAMETER AND A LENGTH EQUAL TO AT LEAST THE LENGTH OF THE THREADED PORTION. THE THREADED PORTION OF THE SCREW SHALL BE INSERTED IN ITS LEAD HOLE BY TURNING WITH A WRENCH. SOAP OR OTHER LUBRICANT SHALL BE USED ON THE SCREWS OR IN THE LEAD HOLE TO FACILITATE INSERTION AND PREVENT DAMAGE TO THE SCREW. LAG SCREWS SHALL NOT BE DRIVEN WITH A HAMMER. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS IN THESE GENERAL NOTES FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. METAL -PLATE -CONNECTED WOOD TRUSSES: SHALL BE MANUFACTURED AND INSTALLED WITHIN THE JURISDICTION REQUIREMENTS, AND DESIGNED AND DETAILED IN ACCORDANCE WITH ANSI/TP-1, INCLUDING BRACING AND WIND UPLIFT. PROVIDE 2x6 TOP CHORDS, AND 2x4 BOTTOM CHORDS AND WEBS, UNLESS COORDINATED AND APPROVED. TRUSSES SHALL BE DESIGNED TO CARRY THE LOADS LISTED IN THE DESIGN CRITERIA AND ANY ADDITIONAL LOADS INDICATED ON THE FRAMING PLANS AND DETAILS. TRUSSES INDICATED ON PLANS ARE FOR TYPICAL UNIFORMLY LOADED CONDITIONS. MANUFACTURER SHALL PROVIDE ADDITIONAL OR SPECIAL TRUSSES AS REQUIRED TO SUPPORT SPECIAL LOADING CONDITIONS AS INDICATED ON DRAWINGS. PROVIDE INSTALLATION FRAMING PLANS AND DRAWINGS. PROVIDE CERTIFICATE OF CONFORMANCE FROM AN INDEPENDENT TESTING LABORATORY OR A LICENSED PROFESSIONAL ENGINEER CERTIFYING THAT THEY HAVE INSPECTED THE FINISHED TRUSSES AND THAT ALL TRUSSES ARE CONSTRUCTED IN CONFORMANCE WITH THE TRUSS DESIGN DRAWINGS. I -JOISTS: SHALL BE APA EWS PERFORMANCE RATED I -JOISTS (PRI) OR PRE -APPROVED EQUAL. I -JOISTS SHALL BE MANUFACTURED IN CONFORMANCE WITH APA PRI-400 CONFORMING TO APPROVED SHOP AND INSTALLATION DRAWINGS. U J J W :. Y >O> z N J �� � �� rn � o��� U � � O N (6 M � m ��� � ��� H N W N O N M ��� �f o `PW� W � E Q o� z /�w"�o w� �o`� 4 J W 0 W W U Z W 0 W W 0 o N W o — � rn �� � N Jo W J z mo w = � � °No �w W O z J Q W w WJ H H 2. CONNECTORS: JOIST HANGERS, STRAPS, FRAMING CONNECTORS, COLUMN CAPS AND BASES, ETC. - FASTENERS: MACHINE BOLTS, ANCHOR BOLTS AND LAG SCREWS WITH ASSOCIATED PLATE WASHERS AND NUTS. NAILS, SPIKES, WOOD SCREWS, ETC. w 3. G60, G90 & G185 PER ASTM A653 FOR COLD -FORMED STEEL CONNECTORS. BATCH/POST HOT -DIP GALVANIZED PER ASTM A123 FOR CONNECTORS. HOT -DIP GALVANIZED PER ASTM A153 FOR FASTENERS w OR MECHANICALLY GALVANIZED FASTENERS PER ASTM B695, CLASS 55 OR GREATER. N o Z ;� � N m Q O � N RES U B SHEET Jun 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ■ U J J W O Z O J Z N I..L Q � � � �rn � U ���� U p N (6 M � � m E���1 N O � V Cis ��Nw /� \ / / \ \ o N M / / / / \ \ \ \ � ti}G P f� / / / \ \ � � �w � NEE" 6 / / \ \ EXISTING CRAWL \ I I dr '�b�S ��0 � / / \ SPACE ACCESS J L 4.�0 — — / // / / \ \ I I �---------------� I I // / �-----------� �------------------� I I // // / I I I I / I I // // / / I I I I I I I / / / I I I I / / / F+�� I i I FT-z.5 �— � I I / cq�A-9�'�'c I // // I I I < � � c� �'o I I I® I I I \\\ \\\ � s ti ����'�� I I L--J I ���' I /�l /�l /�l /�l /�l /�l /�l /11 I �--- i I \ \ / I \ \ / / \ \ / / I I \ \ / / \ \ / / I I \ \ \ \ / / / / I I \\ \\ ��1 ��1 ��1 ��l ��1 ��1 ��1 ��1 ��l ��� I I // // I I \\ \\ \ \ // // / / I I I I � \ \ / / I I O \\ \\ // // I I � \ \ / / EXISTING CRAWL I I W \ \\ \ / \\ / SPACE &FOOTINGS I I // // TO REMAIN I I U \ / \ / FT-2.5 I I 7 L / 1 �------------- �— �---------------� I W � II I I � II I/� /,� /� �-----------J r-----------�--� 1 1 1 ----------------- J v' W I I I I ` � `'- � `_._. � I � �-'1 I I I I �----------- I W `�/ I � j 0 I I � o I I I �-�l �-�l W � I I I `'- � `'- � Q I l �� I � � I ` �� ��� �/ I `/ N I I I I J z I ��� ��� ��� I I � W m o I `�.� `�'� `�.� I I �_ �, o /�1 I I i i i /�l �� oo w I I I I I I I I I I I j �------------------� I I I I � -, � 1 I I � 1 Z ``-� L-----------------------J ``-� J Z O Q z w � w FOUNDATION PLAN w SCALE : 1/4 " = 1'- 0" c� O N Z LJJ � p O � N RES U B SHEET Jun 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ■ FOUNDATION NOTES: 1. DO NOT SCALE DRAWINGS, REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 2. BOTTOM OF EXTERIOR FOOTINGS SHALL BE MINIMUM 12" BELOW GRADE. 3. 4" CONCRETE SLAB OVER 6MIL VAPOR BARRIER ON 6" PF GRAVEL OR CRUSHED ROCK OVER FIRM UNDISTURBED SOIL OR ENGINEERED COMPACTED BACK -FILL. REINFORCE WITH 6 x 6 W1.4 x W1.4 WWF. 4. ALL WOOD IN CONTACT WITH CONCRETE SHOULD BE PRESSURE TREATED WOOD. 5. REFER TO GENERAL STRUCTURAL NOTES PAGE ON S0.0 FOR ADDITIONAL REQUIREMENTS. FOOTING SCHEDULES DIMENSIONS &REINFORCEMENT MAX CAPACITY LENGTH & ROUND LONG. & TRANS. TYPE (LBS) WIDTH DEPTH OPTION NO. SIZE SQ RND FT-1.5 18" 10" 18" f�l 3 #4 2750 2200 FT-2.0 24" 10" 24" Q1 4 #4 4750 3750 FT-2.5 30" 10" 30" Q1 5 #4 7500 6000 FT-3.0 36" 12" 36" Q1 5 #4 10500 8500 FT-3.5 42" 12" - 6 #4 15000 - FT-4.0 48" 12" - 8 #4 18500 - FT-5.0 60" 12" - 8 #4 30000 - IMPORTANT NOTE: EXTERIOR FOOTINGS W/ FROST DEPTH UP TO 12" ,USE 12" THICK FOOTING. FROST DEPTH GREATER THAN 12", PLEASE USE STANCHION AS SHOWN. 1�) NOTES: (�) °o ° 0 0, (z) 1. POST PER PLAN ° o o 2. SIMPSON ABU POST !zl (31 ° o> (31 .;,:. BASE PER PLAN '�'� ' �* <.: :. 3. FOOTING PER PLAN .;.�... • � FT-X.X TYPICAL FOOTING TYPICAL ABU POST BASE TYPICAL ABU POST BASE CALL OUT CONNECTION W/ STANCHION ADDITIONAL NOTES 1. POSTS SHOWN ON THE FOUNDATION PLAN ARE THOSE DIRECTLY CONNECTED TO THE FOUNDATION WITH A HOEDOWN OR POST BASE CONNECTOR. 2. ALL FOOTINGS, FOUNDATIONS, EXCAVATIONS, GRADING, AND FILL SHALL COMPLY TO THE PROVISIONS OF THE INTERNATIONAL BUILDING CODE W/ LOCAL AMENDMENTS. 3. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL MEASUREMENTS AGAINST THE ARCHITECTURAL PLAN SET. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE FOR AND DESIGNER BEFORE FORMING AND/OR POURING CONCRETE. 4. ALL FOOTINGS CAPACITIES ARE SHOWN ABOVE BASED ON 1500 PSF SOIL BEARING PRESSURE. U J CL W O Z Y J O Z (V I..L Q � � � �rn � U���� U p � N (6 M m s= � (� C1� � � N W N 0 N M dr���l o G � �� z w '� c� o U � 4w �~ �'� ��s 4o�w�' 4 �+'s� -��, %� qc � ���qs`��C� (E) BEAM �i — -® OFj� (E) BEAM — � � — — J W 0 EXISTING 9-1/2" TJI FLOOR JOISTS @ 16" O.C. W I..L W U Z W 0 (E) BEAM Cn - - W W � o N (E) BEAM O� � Q N J�' (E) BEAM Q 0 � I j Z � � _ _ W I m U m p � � W I w o_ � � �� m W z O J � O J C� L!L Z � � C� Q � � � � w FIRST FLOOR FRAMING PLAN w SCALE : 1 /4 " = 1'- 0" N O LLJ � � � m p O � N RES U B SHEET Jun 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ■ FLOOR FRAMING NOTES: 1. DO NOT SCALE DRAWINGS, REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 2. FLOOR SHEATHING SHALL BE 3/4" TONGUE AND GROOVE A.P.A. RATED PLYWOOD OR OSB PANELS. (EXPOSURE 1, SPAN RATING 48/24). GLUE AND NAIL SHEATHING AT ALL FRAMED PANEL EDGES WITH 10d AT 6" O.C. AND TO ALL INTERMEDIATE FRAMING AT 12" O.0 3. HEADERS OVER DOORS AND WINDOW OPENINGS SHALL BE MINIMUM 4x10'S U.N.O. 4. PROVIDE (2) STUDS MINIMUM AT EACH END OF ALL BEAMS U.N.O. ON PLANS. BEAR BEAM FULLY ON BUILT UP COLUMN AND PROVIDE POSITIVE CONNECTION BY EITHER A35 OR LTP4 CLIPS ON EACH SIDE OF BEAM 5. ALL EXTERIOR WALLS SHALL BE SW1 U.N.O. 6. REFER TO GENERAL STRUCTURAL NOTE PAGE ON S0.0 FOR ADDITIONAL REQUIREMENTS FLOOR BEAM SCHEDULE HDR: 4 x 8 DF-L N0.2 (UP TO 4'); 4 x 10 DF-L N0.2 (UP TO 6'); 4 x 12 DF-L N0.2 (UP TO 8') POST &TRIMMER &WALL SCHEDULE ® (x3) 2x TRIMMERS + *ALL TRIMMERS AND KING (x3) 2x KING STUDS. STUDS SHALL CONFORM (x2) 2x TRIMMERS + PER DETAIL 3/S4.0 UNLESS ® (x2) 2x KING STUDS. NOTED OTHERWISE. ® 6x6 POST ® POST BELOW ® 4x4 POST X POST FROM ABOVE ® 4x6 POST 0 LOAD BEARING WALL 0 EXISTING WALL PARTITION WALL u SECOND FLOOR FRAMING PLAN SCALE : 1 /4 " = 1'- 0" FLOOR FRAMING NOTES: 1. DO NOT SCALE DRAWINGS, REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 2. FLOOR SHEATHING SHALL BE 3/4" TONGUE AND GROOVE A.P.A. RATED PLYWOOD OR OSB PANELS. (EXPOSURE 1, SPAN RATING 48/24). GLUE AND NAIL SHEATHING AT ALL FRAMED PANEL EDGES WITH 10d AT 6" O.C. AND TO ALL INTERMEDIATE FRAMING AT 12" O.0 3. HEADERS OVER DOORS AND WINDOW OPENINGS SHALL BE MINIMUM 4x10'S U.N.O. 4. PROVIDE (2) STUDS MINIMUM AT EACH END OF ALL BEAMS U.N.O. ON PLANS. BEAR BEAM FULLY ON BUILT UP COLUMN AND PROVIDE POSITIVE CONNECTION BY EITHER A35 OR LTP4 CLIPS ON EACH SIDE OF BEAM 5. ALL EXTERIOR WALLS SHALL BE SW1 U.N.O. 6. REFER TO GENERAL STRUCTURAL NOTE PAGE ON S0.0 FOR ADDITIONAL REQUIREMENTS FLOOR BEAM SCHEDULE FB-1: 5-1/2" x 15" 24F-V4 DF GLULAM HDR-1: 5-1/2" x 10-1/2" 24F-V4 DF GLULAM POST &TRIMMER &WALL SCHEDULE ® (x3) 2x TRIMMERS + *ALL TRIMMERS AND KING (x3) 2x KING STUDS. STUDS SHALL CONFORM (x2) 2x TRIMMERS + PER DETAIL 3/S4.0 UNLESS ® (x2) 2x KING STUDS. NOTED OTHERWISE. ® 6x6 POST ® POST BELOW ® 4x4 POST X POST FROM ABOVE ® 4x6 POST 0 LOAD BEARING WALL 0 EXISTING WALL PARTITION WALL U J W O Z Y J O I..L Z N Q � � �rn � � U���� U p N (6 M � m � � (� C1� � � N W N i O N M �? �~} PAW W � E Q �' o �c�� �� z ��� @� d,�s �' � �4� � i 440 W 0 C� G W W U Z W 0 W W 0 o N W ao O� j N Jo W J z mo o = �� H �� O z O J � � LL o � z z O � w U Q w � ~ Cn LL w w N O N Z � LJJ H � 00 p O � N RESUB Jun 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET S1.2 EXISTING ROOF SHOWN FOR CONTEXTUAL PURPOSES ONLY ROOF FRAMING NOTES: 1. DO NOT SCALE DRAWINGS, REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 2. HEADERS OVER DOORS AND WINDOW OPENINGS SHALL BE MINIMUM 4X10 U.N.O. 3. PROVIDE (2) STUDS MINIMUM AT EACH END OF ALL BEAMS U.N.O. ON PLANS. BEAR BEAM FULLY ON BUILT UP COLUMN AND PROVIDE POSITIVE CONNECTION BY EITHER A35 OR LTP4 CLIPS ON EACH SIDE OF BEAM 4. REFER TO GENERAL STRUCTURAL NOTE PAGE ON S0.0 FOR ADDITIONAL REQUIREMENTS 5. PANELS SHALL NOT BE LESS THAN 4' X 8' EXCEPT AT BOUNDARIES AND CHANGES IN FRAMING WHERE MINIMUM PANEL DIMENSION SHALL BE 24". ROOF BEAM SCHEDULE RHDR-1: 4 x 12 DF-L N0.2 HDR: 4 x 8 DF-L N0.2 (UP TO 4'); 4 x 10 DF-L N0.2 (UP TO 6'); 4 x 12 DF-L N0.2 (UP TO 8') ROOF SHEATHING SCHEDULE SNOW LOAD NOMINAL SPAN RATING EDGE FIELD (UP TO) THICKNESS NAILING NAILING 40LBS 7/16" 24/16 8d @ 6" O.C. 8d @ 12" O.C. 70LBS 15/32",1/2" 32/16 10d @ 6" O.C. 10d @ 12" O.C. 130LBS 19/32",5/8" 40/20 10d @ 6" O.C. 10d @ 12" O.C. 175LBS 23/32",3/4" 48/24 12d @ 6" O.C. 12d @ 12" O.C. • LONG DIMENSIONS PERPENDICULAR TO ROOF JOIST WITH EDGE SUPPORT R503.2.1.1(1). • NAIL SHEATHING AT ALL FRAMED PANEL EDGES AND TO ALL INTERMEDIATE FRAMING AS SHOWN ABOVE U.N.O. POST &TRIMMER &WALL SCHEDULE ® (x3) 2x TRIMMERS + *ALL TRIMMERS AND KING (x3) 2x KING STUDS. STUDS SHALL CONFORM (x2) 2x TRIMMERS + PER DETAIL 3/S4.0 UNLESS ® (x2) 2x KING STUDS. NOTED OTHERWISE. ® 6x6 POST ® POST BELOW ® 4x4 POST X POST FROM ABOVE ® 4x6 POST 0 LOAD BEARING WALL 0 EXISTING WALL PARTITION WALL U J J W O Z Y J O I..L Z N Q � � �rn � � U���� U p N (6 M � m i=�(� C1� � F- c� w N O N M ��� �f o PW� W � E Q �� z '� � o �w @~ �1 �4,� i 4�0 W 0 C� G W W U Z W 0 W W 0 o N W ao O� j N Jo W J z mo w = � H �� z Q z_ 24" O.C. G Q LL LL w O w ROOF FRAMING PLAN w SCALE : 1 /4 " = 1'- 0" c� O � W N H � 00 '� p o � N RESUB Jun 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT E.yi���� S2.0 MSTC STRAP INSTALLED OVER DOUBLE TOP PLATE. CENTER BETWEEN NEW AND EXISTING WALL. FIRST FLOOR SHEARWALL AND HOEDOWN LAYOUT SCALE : 1 /4 " = 1'- 0" swxx SW1 WALL LEGEND REFER TO SHEARWALL SCHEDULE ON PAGE 4.0 ALL NEW EXTERIOR WALLS SHALL BE SW1 UNLESS NOTED OTHERWISE. U J C!� � ~ w � z J O I..L Z N Q � � � p � U ���� U p � N (6 M m � � ��1 N O � V Cis ��Nw NEW SHEARWALL CI] EXISTING WALL INTERIOR WALL (SHEATHING IS NOT REO'D) J W C� G � W W U Z W �_ W W 0 o N W ao p j ri(� N Jo J Z w � m O � � 00 W N O N M z J Z Q J J Q � � w W � J �_ = � J w w N W N Q c0 p O RESUB Jun 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET S3.0 -0 rn n O � z v r O O 70 � � �_ n rn r m � j �� ,r �- r o � z v 0 r v 0 z r D O c D � � � � x � � x m m z 0 � X m m cn � �_ �_ � p z = � G) m D D � � � D r � r 2 m D = O=� nm � m�z mm i-n o�m �� z Om� �� O � =max m� m ��m Ozm � ��� �D d mm� m� � D � � r � r 0 < L n � m o < � 1'7'7 � 1''^1 DSO � Y/ AZO mono N �Az O <o N � � m � DATE GZN S� STRUCTURAL WORKS PLLC m TITLE PROJECT �' pF WAsg � � 06/12/24PERMITSET SHEARWALL AND HOEDOWN THE IZQUIERDE RESIDENCE REMODEL ��� f�� - ' ��� 1412 Beach Drive NE W LAYOUT 821 BELL ST Tacoma, WA 98422 � JOB NO EDMONDS, WA 98020 �,� 50294 � 253-533-0835 24156 o��SI�NALE��'1��� ES@STRUCTURALWORKS.NET 06/13/2024 LOCATE HDR ®TOP OF WALL OR ®TOP OF OPENING ®CONTRACTOR'S OPTION UNLESS INDICATED OTHERWISE BY NO HORIZ PW NOIE: JOINTS FOR PRO FULL BEARING UNDER GIRDER TRUSSES. MIN.�� 2X6 STUDS BUILT UP COLUMN J LOCATION OF HDR'S WHERE REQ'D. ARCHITECT OR ENGINEER. LENGTH OF STRAP ® UNDERSIDE of TOP R -SEE NOTE (4) FOR HDR SIZE UNLESS NOTED (2) 16d INTO EACH STUD ®TOP / 11 ) NOTES: O7HERWISE ON FLOOR PLAN. & BOTTOM. P (�) i6d INTO SOLID WOOD COL zxs BLKc. HEADER AND BEAM SCHEDULE FOR LOAD BEARING WALLS -- SIMPSON MST 46 ®JOINT IN WALL R. INSTALL STRAP (2) i6d a Nu si>zAP. // 1. WOOD STUD WALL > » 6 -O MINIMUM LAP NOTES: OVER WALL SHEATHING �' SIMPSON MST 48 ®CHANGE IN WALL R HEICIIr. \2) TRIMMERS REQ'D KING STUDS REQ'D 1. TOP PLATE SPLICE (3) 2. WOOD HEADER PER PLAN OPENING SIZE HEADER SIZE 2X4 2X6 2X4 2X6 16d NAILS � 4" O.C. (1) OVER STUD ONLY. � W 3. (2) 16d TOENAILS -EACH 0 Z - = (z) sa (z)1sa (4) SIDE, EACH END UP TO 3'-6" SEE PLAN 1 1 1 1 2. DOUBLE TOP PLATE. � (�j (3) (3) STUD B.U. COL. IYP. i6d TOENAILS ®CTR FULL HEIGHT TOENAILS IYP. E0. EQ. (5) 4. (3) 16d NAILS AS SHOWN 3'-6"> TO 5'-0" SEE PLAN 2 1 2 2 J O lYP U.N.O. W/(1) FULL HGT. STUD STUD HDR CONN. TO , „ , „ (2\ l / Q W P AN � �� (1) HORIZ 'MOTH FACE of COL. 5. RUN VERTICAL STUDS UP 5 -0 > TO 8 -0 SEE PLAN 2 1 2 2 (3) Z N Q STUDS REO'D -LAM W/16d ® FULL STUDS TO MATCH WALL 2X S7UDS SEE PLAN FOR SIZE PAST HEADER AS SHOWN (6) �/ � � a' O.C. TYP. STUDS ®TOP & Bon. of SOLID WOOD L. OR dcL�RUSS BRGD(TYP)IST 6. (2) 16d NAILS AT 12 O.C. 8'-0"> TO 10'-6" SEE PLAN 3 2 3 3 � � Q � Q U ADDITIONAL STUD ®HDR OPNGS. COL. SEE PLAN (7) r n r r 10 -6 > TO 16 -0' SEE PLAN 4 3 3 3 (, � � � � p SIMPSON A35 ® EA. B.U. COL. BRG. WHERE MORE THAN 7. DOUBLE STUDS UNDER � WHERE OPENING WIDTH EXCEEDS (3) B.U. STUDS REQ'D (z) STUDS MIN ®HDA HEADER BEARINGS FOR OPENING WIDTHS GREATER � � m (6 M � � � B'-D° (z) ,sd THAN 5 -0 NOTES: � � � � � roENAILs T'P' -UNLESS NOTED OTHERWISE, ALL BEAM AND HEADER SUPPORTS SHALL CONFORM TO THIS SCHEDULE CJ� � co Ln (n ROUGH OPENING WIDTH � H c� W - ALL BUILT-UP SUPPORTS WILL MATCH OR EXCEED WIDTH OF SUPPORTED BEAM oMIT eon. R slMPsoN HD WHERE -ALL HEADERS ARE TO BE 4X10 DF-L N0.2 UNLESS NOTED OTHERWISE ® DOORS IYP. REO'D. SEE PLANS FOR SX 1REATED R TO FOR SHEARWALL SCHEDULE, SIZE. MATCH WALL WIDTH. STUD A.B. SIZE &SPACING (7" MIN. EMBED) N O TYPICAL EXTERIOR +INTERIOR BEARING WALL FRAMING ELEVATION WOOD HEADER (DROPPED) HEADER AND BEAM SCHEDULE FOR LOAD BEARING WALLS TYPICAL SPLICE OF TOP PLATES M 1 r� L r� 3 � ����r SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. G � o NOTES: z, w o� x 1. PARTIAL DROP BEAM PER PLAN PROVIDE PLAYWOOD U � 4w �~' (11 EPTH SHIM MAT"L. AT BEAM TO KING STUD IF �� ��S .¢0��� 11) REQ"D. 4 (7) \2) / (7) (2) (9) (7) 2. SIMPSON ST6224 (U.N.O.) NAIL W/ 16d SINKER OR 10d COMMON NAILS NOTES: 3. (1) 16d SHORT NIAL FOR EACH 2" OF BEAM DEPTH 1. BASE PLATE NAILING PER AT EACH SIDE OF BEAM SHEARWALL SCHEDULE (15 4. srs224 2. PLYWOOD SHEATHING (10) (14) 5. 2x sruD (1) (3) 6. SIMPSON A34 EACH SIDE AT TOP BOTTOM NAIL 3. PLYWOOD WEB JOISTS PER PLAN (6) (9) (5) W/(4) 8d COMMON NAILS AT EACH SIDE OF A34 TO (2) (7) ll (3) (4) FRAMING 4. WOOD BEAM PER PLAN (8) (5) 7. DBL. TOP PLATE (5) 5. BLOCKING AT 48" O.C. BY JOIST 8. POST OR MULTI- STUD PER PLAN MANUFACTURER (4) ($) (4) 9. SIMPSON A35 EACH SIDE AT TOP BOTTOM NAIL W/(4) 8d COMMON NAILS AT EACH SIDE OF A34 TO (6) 6. SIMPSON IUS OR LLU TYPE FRAMING HANGER (8) (16 (4) 10. DROP BEAM PER PLAN PROVIDE PLAYWOOD FULL OPTION A OPTION B SHIM MAT"L. AT BEAM TO KING STUD IF 7. (6) #8 SCREWS PER BLOCK - REOTDH (5) (4) 10d NAILS ALTERNATE 11. FLUSH BEAM PER PLAN (3) (12) 12. PI�MPE H8 CONNECTOR AT E. FACE OF POST TO SILL (13� 13. SILL PLATE � 14. A35 AT EACH SIDE OF POST TO SILL PLATE 15. WHERE OCCURS 0 PTI O N C PLYWOOD WEB JOIST AT WOOD BEAM TYPICAL BEAM TO POST WITH TOP PLATE 16. TS22 OR HTS24 BOTH SIDE 6 'J �0 5 SCALE: N.T.S. SCALE: N.T.S. O G END LENGTH END LENGTH NOTES: SHEAR WALL SCHEDULE L1J (4) (1) 1. SIMPSON CS16 STRAP PER TABLE NOTES: FRAMING AT FOUNDATION SILL WALL SHEATHING SIDES PANEL EDGE FIELD ADJA ANEL BASE PLATE ANCHOR BOLT PLATE/PLATE BASE BLOCKING/RIM w 2. DBL TOP PLATE 1 1. TYPICAL 2X STUDS AT 16" O.C. U.N.O. MARK NAILING NAILING EDGES ATTACHMENT SPACING JOIST ATTACHMENT U 5 W/ (2) 16d END NAILS OR (4) 8d TOE 3. 2X STUD.OR POST PER PLAN 2 NAILS EACH END TO TOP &SILL PLATES. z (1) SW1 7/16" OSB ONE 8d NAILS 12" O.C. 2x 16d NAILS AT 5/8" DIAMETER BOLTS 2x SIMPSON A35 CLIPS Q 4. BEAM PER PLAN 2. CORNER STUDS OR POST PER PLAN. AT 6 O.C. 6 O.C. AT 48 O.C. AT 18" O.C. (2) 3. PLYWOOD SHEAR PANEL PER PLAN. Cn w 1 4. POST AT END OF SHEAR PANEL PER SHEAR WALL SCHEDULE NOTES: � (2) PLAN. 3 FRAMING STUDS SHALL BE DOUGLAS-FIR #2 SPACED AT 16" O.C. MAXIMUM. THICKNESS OF STUDS SHALL BE 2x UNLESS OTHERWISE NOTED IN SCHEDULE. w 4 5. NAIL CORNER &MULTI -STUDS TOGETHER STRAP SELECTION s 1" 1" W/ 16d'S � 16" O.C. STAGGERED � SHEATHING PANELS MAY BE PLACED VERTICAL OR HORIZONTAL. BLOCK ALL HORIZONTAL EDGES WITH 2x OR 3x BLOCKING TO MATCH STUD WIDTH UNLESS NOTED OTHERWISE. � o END LENGTH TOTAL FASTENERS CAPACITY OVERLAP OVERLAP WALLS. WALLS & 24" O.C. ®NON -SHEAR ALL EXTERIOR WALLS NOT DESIGNATED AS SHEARWALLS SHALL RECEIVE APA RATED SHEATHING, FULLY BLOCKED WITH MINIMUM EDGE ATTACHMENT OF 8d NAILS (� 6" O.C., 12" O.C. FIELD. w � TYPE (INCH) FASTENERS PER MEMBER (LBS) 3 � s 3 NAILING APPLIES TO ALL STUDS, TOP AND BOTTOM PLATES AND BLOCKING. � Q A (2) 16d � 4" O.C. a 6. EDGE NAILING MINIMUM ANCHOR BOLT SPACING OF 48" O.C. UNLESS OTHERWISE NOTED IN SCHEDULE. MINIMUM OF 2 ANCHORS PER WALL. PROVIDE 3"x3"x0.25" SQUARE WASHERS AT EACH ANCHOR � � 24" 12 1705 7. 16d's (� 4" O.C. STAGGERED BETWEEN TH � SILL PLATE AND WASHER. A DIAGONAL SLOT IN THE PLATE WASHER MAY BE USED WITH A WIDTH OF UP TO 3/16" LARGER THAN THE BOLT DIAMETER AND A SLOT NOT TO N r� uj EXCEED 1-3 4, PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. DO NOT RECESS BOLTS. _ � p B 36" (2) 16d � 4" O.C. 18 2557 8. 2x STUD � SHEAR BREAK. TABLES BASED ON 8d NAILS (2 1/2" LONG x 0.113" COMMON OR 2 1/2" x 0.113" GALVANIZED BOX). � w m O C 48" (2) 16d � 4" O.C. 24 3410 PLANyTEw WALL TRANSITION NOTE: NAILS SPACED ®2 O.C. SHOULD BE BLOCKING RIM JOIST ATTACHMENT NEED NOT BE USED WHERE THE SHEATHING IS DIRECTLY ATTACHED WITH EDGE NAILING TO THE DOUBLE TOP PLATES AT UPPER STORY SHEARWALLS AND o = � � p STAGGERED MIN. 1/8 . TO THE BASE/SILL PLATE BELOW AT LOWER STORY SHEARWALLS. � � N oo W SELECT TYPE D UNLESS NOTED D 72" (2) 16d � 4" O.C. 36 5115 WHERE 3x BASE/SILL ARE SPECIFIED, 20d COMMON NAILS SHALL BE USED FOR THE BASE PLATE ATTACHMENT IN LIEU OF THE ORIGINALLY SPECIFIED 16d COMMON NAILS. BEAM DRAG 8 SHEARWALL INTERSECTION FRAMING 9 SHEARWALL SCHEDULE SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. Z (1) I I � (2) NOTES: 1. EXISTING CONCRETE STEM WALL (2) (4) 2. EXISTING CONCRETE FOOTING (1) (1) 3. 1'-0" LONG #4 DOWELS - (1) (2) (4) � (4) EMBED 6" MINIMUM IN SIMPSON NOTES: (5) NOTES: � S.E.T. EPDXY (3) 1. CEILING FRAMING BOTTOM CHORD / U J (3) 4. NEW CONCRETE FOOTING 1. ARCHITECTURAL COVER - 5. (1) #4 BAR CONTINUOUS OPTIONAL 2. SIMPSON DTC CLIP AT EACH � Q z (4) BOTTOM CHORD � � � (3) o 2. WOOD COLUMN 6 +I () � � W � Q (5) N 3. WOOD STUD WALL � (n � � 6 6 N o p 3. CBSQ COLUMN BASE (3) � a o D °� II II ° II 4. SIMPSON DTC CLIP AT 2' O.C. � � D o D Illllll�lii�- o D°.° D ° IIIIIIIIIII 4. CONCRETE SLAB OR FINISH (3) D o � D � ° D D. GRADE AS OCCURS 5 2 16D NAILS ( ) (5) II (5) ° • ° � � o 0 5. CONCRETE FOOTING PER 6. 2X4 FLAT AT 2' O.C. � �o�000 °000 000��° 000.� (6) PLAN I I �A��� .�� 6. REINFORCEMENT PER PLAN a �- � ��- PERPENDICULAR TO FRAMING PARALLEL TO FRAMING � o 9" MIN 9" MIN PER PLAN a � o Q O � CV �� SHEET RES U B PER PLAN Jun 14 2024 FOOTING ADDITION AT EXISTING FOOTING TYPICAL POST TO FOOTING CONNECTION INTERIOR NON -BEARING STUD WALLS AT WOOD TRUSSES CITY OFEDMONDS DEVELOPMENT SERVICES ii II SCALE: N.T.S. SCALE: N.T.S. DEPARTMENT ■ SCALE: N.T.S.