Loading...
APPROVED BLD2023-1397+Architectural_Plan+11.9.2023_6.17.11_PM+3892946Main Floor — as built Deck 1 Laundry Room Balhr 60.90 sq ft 44.05 q Vestibule sgft (16'13/4'Y 13') Dining Room 6'7".9'3' 7'31/2 93.54 140.92 sq ft Living Room 8'41/4'. 17' 426.73 sq ft(21'91/4'+21'73/4') Hall 48.75 sq ft (14'31/4'.3'5') 16 O Dining Rm/Bar Living m Roo 124-77 sq ft 196.39 sq ft (14' 11' s 13' 2") t , Dimensions are approximate. ;separate Plumbing i permit is required for thisproject. Please obtain a I APPROVED ALL WORK SUBJECT OBTAIN ELECTRICAL ■Plumbing permit from the PLANS MUST BE TO FIELD PERMIT FROM ■ INSPECTION FOR STATE LABOR & City of Edmonds J ON JOB SITE INDUSTRIES ■ ■ ■ ■ CODE COMPLIANCE ' • The following documentation shall be available on ' site for the building inspector: ® COE APPROVED ARCHITECTURAL PLAN SET ® COE APPROVED STRUCTURAL PLAN SET : ❑ COE REVIEWED CALCULATION PACKET ■ ❑ ENERGY CREDIT WORKSHEET ❑ SITE PLAN ; ❑ CIVIL PLAN ■ ❑ L • ......... 1.,Ti °::°: °:°::::°:N: °:P:::M::T:::............ . City Of Edmonds Building Department Work REMODEL Address 729 MAIN ST Owner AUSTIN Approved Date 11/29/2023 Building Official 'Daszovtzst W. V Vfk.a-,L Permit Number BLD2023-1397 r■�■�■�■�■�■�■�■�■�■�■� RECEIVED iLOCAL Nov3 EXHAUST FANS SHALL BE PROVIDED IN of oEPaR.ME, ES (EACH KITCHEN, BATHROOM, WATER CLOSET. I 1 1 L 1 1 1 1 Z<O Main Floor —after remodel A JF_ V_ 40 Dining Room 140.76 sq ALiving Room 8'33/4"x17' 431.84 sq ft(21'91/4' x 22'1/4") I� Butler pantry Bathr om 60^^sq tt 44.05 qf# 459 sgft(1('Sex 13'1- 1 / 6' 9' 3' T 3 12 9 Hall 48.76sgft(14'31/4'x3'5') DIning Rm/Bar Living Room 124.77 sq ft 196.44 sq ft (14' 11' x 13' 2") t Dimensions are approximate. 1. Convert laundry room to pantry w/ cabinets on 3 walls & sink/counter on outside wall. Leave window in -place for cost savings. - Cutting in new doorway from hallway - Closing in two existing doorways - Relocate existing plumbing as necessary - Add countertop outlets and wall outlet RECEIVED Nov 13 2023 111ELOP1111 I'll "I Main Floor, Butler Pantry — overhead lighting plan after remodel Pendant / sconce over sink, switched at sink Under counter S outlet for disposer O Wall outlets above counter Wall outlets above counter 7 Ceilingfi ure, switched door U,,„,rcabinet lighting, 5 wall switch switched at door (Da 0 wan uun�t Q ce,imQflush --tea light SSg«ems d light X wall mounted light RECEIVED Nov 13 2023 Main Floor, Butler Pantry — elevation after remodel gg Full depth counter 5 wall switch os M wmioun,,s Q ce�hoQ nosh m000aa light a«�scd light Right wall cabinets Back wall cabinets X wallmoomeehaht pen shelvin (adjustable) Full depth counter Deep rawers Possible beverage fridge • • French glass /brass bistro shelving Backsplash covers entire wall Counte RECEIVED Nov 13 2023 Main Floor, Butler Pantry — elevation after remodel OpeR Under -cabinet lighting Small counter SWall switch Qor M wml ounet 0 CeJmg flush mounted light RRecessed light Right wall cabinets X wall mounted light SERVICES cub ies Pantry II -outs Appliance shelf w/ backspl ash (Coffee, Ice Maker, Instapot, toaster, blender) • • i i i i • Wide drawers f deep • r platters •DEVELOPMENT RECEIVED Nov 13 2023 Main Floor, Kitchen & Family Room — lighting plan after remodel Esisbg wlEoor wa 1^e waM ^eeoem Nyh mount aNN Ip N S / Wn Downlphl N �� urtlar raYb i 1yMalaaa i Eail111paily6Me i Im+a{Ryn}tla) � `_ e____.. MaYOVght l C; ssss LenJ� Lan Unh �l Fbv o-- �l L�aala��,�, rn g SSSS olalal �Eaismg oNOoor scanws � I^o+m^`^��Ir Oullel la under S wall switch � — — raeinel lgms wr aeabe }0 cellmg nosh moulten light i X T accessed light X wan mounted light RECEIVED Nov 13 2023 OEPARTMENT DEVELOPMENT SERVICES Second Floor —as built Guest Bedroom Closet 8 Porch v Guest Bedroom G st Walk-in closet o Closet u Office z<0 Dimensions are approximate. RECEIVED Nov 13 2023 LOCAL EXHAUST FANS SHALL BE PROVIDED IN (EACH KITCHEN, BATHROOM, WATER CLOSET. Second Floor —after remodel a o 2 3 r 6 os " ❑ 4 Closet Porch v Guest Bedroom l� Batst o � Closet v Office z<0 Dimensions are approximate. Changes on Second Floor Second Floor 1. Relocate toilet to new location in existing closet - Add door to toilet room 2. Divide extra bedroom. Use a/ space to create laundry room; use remaining % to expand master bath. 3. Full bath remodel; new cabinets, countertops, floor and shower tile, sinks, tub - Close both existing door openings. Create new opening across from toilet room - Close up existing small window - Install new exterior window — size and exact location tbd - New electrical for outlets and lighting - Add or reuse HVAC register in new master bath 4. New laundry room w/ new cabinets, utility sink, and LVT flooring - Move existing bedroom door slightly left to accommodate new laundry room cabinets 5. Install new hardwoods in master bedroom, hallway and new toilet room - Materials already on site 6. Remove existing carpet on stairs and convert treads to wood + runner. - stain -grade bull -nosed treads, espresso stain treads and handrail - Paint spindles and risers white to match trim 7. New wall paint throughout - New trim paint to match downstairs trim Notes: - Reusing existing door and window casing and baseboard trim RECEIVED Nov 13 2023 I Second Floor —after remodel Confirm no Changes (inside wall to inside wall dimensions) to this wall 164 1/2" 96" ? ? 6 • "' Closet ? --►� � •• 106" 28„ _ Guest bedroom 0 L ,�1 Geest Q Bath � 7 closet \ CMl to z Dimensions are approximate. RECEIVED Nov 13 2023 OEPARTMENT DEVELOPMENT SERVICES Second Floor — main bath & laundry room lighting plan after remodel Laundry basket & Linen folding ontge R sewing work space oa RI 1 I I R Iv W/D stacked l 240V I I S wall switch \ O CeJmg flush mounted light * light Dimensions are approximate. X wall mounted light LOCAL EXHAUST FANS SHALL BE PROVIDED IN (EACH KITCHEN, BATHROOM, WATER CLOSET. RECEIVED Nov 13 2023 10 Master Bath, vanity — elevation after remodel Wall sconces Ar SWall switch o� wml o.net 0 CeJmg flush mounted light RRecessed light Back wall cabinets X Wall mounted light X x X RECEIVED Nov 13 2023 OEPARTMENT DEVELOPMENT SERVICES 11 Second Floor —toilet room & guest bath lighting plan after remodel b S wan switch `gr= or N wall outlet \ '-" JOB Ceiling flush mounted light ���—�) 2 4- Recessed light Dimensions are approximate. X Wall mounted light RECEIVED Nov 13 2023 D—OPMENT SERVICES OEPARTMENT 12