Loading...
APPROVED BLD2024-1106+Architectural_Plan+8.24.2024_12.28.53_PM+4460813! The following documentation shall be available on site for the building inspector: ■ ! ❑ COE APPROVED ARCHITECTURAL PLAN SET ■ ❑ COE APPROVED STRUCTURAL PLAN SET ; ❑ COE REVIEWED CALCULATION PACKET ' ! ❑ ENERGY CREDIT WORKSHEET ■ ❑ SITE PLAN ; ❑ CIVIL PLAN ■ !Fx] WASTE MANAGEMENT ■ :❑ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ■ A SEPARATE PLUMBING PERMIT IS REQUIRED. PLEASE OBTAIN A PLUMBING PERMIT FROM THE CITY OF EDMONDS r- — - — - — - — - — - — - — - — A waste management form is to be provided to the area I inspector upon request. This ' form is to be completed throughout the construction of I the permit. I- — - — - — - — - — - — - — - — APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES City Of Edmonds Building Department Work ------- ----------- REMODEL ------------------ Address 18829 94TH AVE W ----------------------------- Owner ; ----------- WHALEN Approved Date ; 9/12/2024 Building Official �oxo�aK ----------------------------- Permit Number ----------------------------- BLD2024-1106 BLD2024-1106 Aup 26 2024 CI OF EDMONDS EVE L PMENT SERVICES O (/) (n I o CD rn o w N M r` w 00 LLJ Q C Z � Co O� a3 0 00 ` Et�snn` s�' LLJ 111 s1 m - JLLJ W -E%ISIMG AShMET AV TO IIEMMN� Q 20.00' 1 N cc G (7 00 E1'00 22" W o Q a> Q J J V no D P " PO PROPOSED - SITE PLAN 1"=10'-011 NO EXTERIOR WORK A CD WHALEN 18829 94TH AVE W - PLANS.AI ----- B ----------------------------------------- I --- sm caz BEDROOM 1 BEDROOM 1 LIVING ROOM LIVING ROOM sDl REPLACE CD2 EXISTING EXTERIOR & INTERIOR REPLACE INTERIOR WALLS TO DOORS AS INTERIOR REMAIN. REPLACE ROOF. REQUIRED DOORS AS REPLACE ALL WINDOWS REQUIRED w/ MAX. U VALUE 0.30 WINDOWS x•s � DINING � y DINING -- •.RE m PLAC �[MwR waiawRoarrin �-..�. ' CABINETS& I 4"dia.duct ..... _.._L ---------------50 dm `p 100dm REMOVE KITCHEN BEDROOM 2 £i e REPLACE roposed ATTICACC ESS CAB NETS & FIXTURES REPLACE = 22"x30" CABINETS & _ CABINETS S E E I V E KITCHEN ONE I_ WINDOW w/ DOOR KITCHEN BEDROOM 2 Aug26 2024 CITY OF EDMONDS DEVEL PMENT SERVICES _ sUl EPARTMENT • I ""'" WIH ------ } + Cn 1---'.REMOVE -_, F&URNACE CLOSET Ln N ....... MASONRY (] CT CHIMNEY - SDI CO2 POCKET ODOR 6'or7' � M w 00 FAMILY ROOM CARPORT L? CARPORT Ln w N 4"dia. uct7 50 d 14x11 O FAMILY ROOMCo CT C) } — 0- EXISTING FLOOR PLAN PROPOSED FLOOR PLAN o CONDITIONED AREA = 1190 SF CARPORT AREA = 458 1 CONDITIONED AREA = 1190 SF CARPORT AREA = 458 SF n C� CLLJ TOTAL BUILDING FOOTPRINT 1648 SF t! _ , TOTAL BUILDING FOOTPRINT = 1648 SF y = ROOF AREA = 1838 SF ROOF AREA = 1838 SF J L.IJ L-LJ N Q LLJ 0f w 0- J N 00 O CC) . LL OJ . .. -. J J V .� WHALEN 18829 94TH AVE W - PLANS.AI EXISTING - WEST ELEVATION PROPOSED - WEST ELEVATION El El NO CHANGE EXISTING - SOUTH ELEVATION PROPOSED PROPOSED SOUTH ELEVATION a RECEIVEC Aug 26 2024 Scale: 1/4" = 1'-0" Scale: 1/4" = V-0" CITY DEVELDPMENT [EPARTMENT OF EDMONDS SERVICES EXISTING - EAST ELEVATION PROPOSED - EAST ELEVATION Ln C) 01 U-i 00 L? r Ln U-i CV C� Cz 0- C) 0- Co CO LLJ Co L.0 LLJ EXISTING NORTH ELEVATION PROPOSED NORTH ELEVATION CD Ln =) 0- U-i C:f LIJ 01- >- —j 00 CC) El El Lj-j LU --J __j = m = 3: 3: C:) REMOVE WINDOW L.) "d w S!, Scale: 1/4" = 1'-0" Scale: 1/4" 1'-0' 2 O r) WHALEN 18829 94TH AVE W - PLANS.Al CHANGES TO INTERIOR FRAMING E-W Interior Wall: Kitchen/Dining EXISTING, non -bearing E-W Interior Wall: Kitchen/Dining PROPOSED Roof/Attic runs E-W various sizes, wood framing a WEST Exteruns RE E I V E runs N-1 S Interior Hallway 2x4 wood Interior runs N-S Aug26 2�24 framing 2x4 wood framing Kitchen -Dining Wall WHALEN 18829 94TH AVE W - PLANS.AI WINDOWS Andersen Series 100 0 20-4040-20 O 2640 C BEDROOM 1 LIVING ROOM REPLACE INTERIOR DOORS AS © 2640 C REQUIRED f 11 � DINING rj�': 3 40 P 0 3020 AREP' c _ ma ch k the w/ capn match kitchen caumertop CABINETS & ' FIXTURES 'a C 15' Seep ► Il qbase cab 3626 P ; ' REPLACE 1 CABINETS & IXTURES X)P KITCHEN BEDROOM 2 Item# Spec Size Type Casement -Left* From Floor U-Factor 1 Bed 1 N 2640 Egress 30x48 32-1/2" U-.24 2 Bed 1 E 2640 Egress 30x48 Casement -Left* 32-1/2" U-.24 3 Bathroom 3020 36x24 Awning -Privacy Glass U-.25 4 Bed 2 2640 Egress 30x48 Casement -Left* 32-1/2" U-.24 5 Family Rm S 2926-2 6600 Twin Casement U-.24 / U-.24 6 Family Rm W 20-4040-20 96x48 Picture w/ Flanking Casements U-.24/ U-.23/ U-.24 7 Kitchen S 3026 3600 Casement -Left* U-.24 8 Kitchen N 3626 4200 Picture U-.23 9 Dining Rm 3640 42x48 Picture U-.23 10 Living Rm 20-4040-20 96x48 Picture w/ Flanking Casements U-.24/ U-.23/ U-.24 302 C Q a Q 2640 C 93"wall height 1 O Tonal CLOSET REPLACE WASHER/DRYER & WATER HEATER FAMILY ROOM i 0 2926-2 TC cn 000 30"w x 48" h 80" from floor 48" window height 32-1/2" from floor Window & Door Layout for Estimate 8-15-24.ai RE EIVE Aug26 2024 CITY OF EDMONDS DEVEL PMENT SERVICES DEPARTMENT cr> Lr-) O rn o�, p M w 00 L? LU Ln N Co C3_ O 0_ a� N � 00 00 cri LU m J L.L.1 LU — o z O � ¢ w Qf w cf, 1--- I.-_ 0- J N N — CD CDCC)i L¢L z_ z � J LLJ J V U u � u o o r O r WHALEN 18829 94TH AVE W - PLANS.AI HVAC Ln --------------------------------------- mono 36,000 BTU 19.2 SEER Mitsubishi Quad Zone Heat Pump System 9+9+9+12 Model: MXZ-4C36NA2 / 3-MSZ FS09 / MSZ-FS12 11 review(s) $5,925.00 RE EIVED Aug26 2024 CITY OF EDMONDS DEVEL PMENT SERVICES o o rn a M w 00 L? Ln Lu CV Q Cll O` _O 0- O CN 00 CO C/ Lu Q m J L1J L1J a z o N = Lu Qf w O` J N CN CD CDC C) i z z � L.LJ LLJ a--+ J J V _ = i U u O ? O o- O r WHALEN 18829 94TH AVE W - PLANS.AI