REV1 APPROVED BLD BLD2024-1106+STRUCTURAL INFO +9.27.2024_3.11 (2)MS2 McCann Structural Solutions REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION Vo'7LVILiL OVfka.(L September 11, 2024 BUI Oct08200F4CIAL APPROVED DATE Ms. Stephanie Bates, Delegate for Whalen Remodel 18823 94`h Ave. W. Edmonds, WA 98020 STRUCTURAL REVIEW LETTER BLD2024-1106 THE FOLLOWING DOCUMENTATION SHALL BE AVAILABLE ON SITE FOR THE BUILDING INSPECTOR: REVISION ❑ COE APPROVED ARCHITECTURAL PLAN SET Sep 27 2024 ❑ COE APPROVED STRUCTURAL PLAN SET " D'l ..T" es []COE REVIEWED CALCULATION PACKET ❑ ENERGY CREDIT WORKSHEET ❑SITE PLAN RECEIVED ❑ CIVIL PLAN Sep 27 2024 ® Original approved plans of ❑ V-LoEPAR,MEN, Subject: Verification of Existing and Proposed Wood Framing MS2 Project #: 24-145 at 18829 94th Ave. W, Edmonds, WA 98020 Dear Ms. Bates: On September 6, 2024, a site visit was made by Michael McCann of McCann Structural Solutions to the existing structure at the above address to review the existing and proposed wood framing of the roof structure. Mr. McCann is a licensed Civil and Structural Engineer in the State of Washington. During the site visit, Mr. McCann was accompanied by Ms. Bates, and the contractor, Phil Whalen. No existing drawings or Geotechnical Report were available for review during or after the site visit. Pictures were taken of the interior and exterior of the residence, and a selected few are included in this report. PROJECT DESCRIPTION The existing structure is a wood framed rambler with a stick framed roof and ceiling. At the time of the site visit, all the interior sheetrock had been removed exposing the existing framing of the roof structure and the walls, both interior and exterior. The floor is a slab -on - grade — there is no crawlspace. The contractor pointed out five areas where new beams or ceiling joists are proposed to be installed. The structure was constructed in 1941 according to Ms. Bates, and there is evidence of many remodels over the years. STRUCTURAL ISSUES REQUIRING CALCULATIONS (See attached Calculations) Item #1: 2X6 Ceiling Joists Spanning 16 Feet Item #2: 14 foot 2X6 Ceiling Joists With New 4X10 Beam Item #3: Double 2X6 Ceiling Joists Spanning 10 Feet With Roof Point Load Item #4: 4X10 Beam Over Eight Foot Window With Roof And Ceiling Load Item #S: Eight -Foot -Long Beam Over Eight Foot Window Centered on Ridge Above STRUCTURAL OBSERVATIONS • The center bearing wall top plate is discontinuous. • In many areas, due to many remodels over the years, the framing is less than standard. • There is less than six inches of clearance between the wood sill plate of the exterior wall and the exterior finish grade. 0 There are many areas of wood deterioration noted in the plates and studs. STRUCTURAL CONCLUSIONS • As outlined in the attached calculations, the solutions given are structurally adequate. • The top plate of the center bearing wall is not structurally functional. • The existing framing, in many areas of the structure, is sub -standard. • The lack of vertical clearance between the exterior wall bottom plate and the finish grade encourages rot of the wood and water intrusion onto the existing slab -on -grade. RECOMMENDATIONS FROM CALCULATIONS Item #l: 2X6 ceiling joists *16" on center are structurally insufficient. Item #2: New 2X8 ceiling joists turned 90 degrees to span 14 feet are sufficient structurally. Additionally, the use of a 4X10, ten -foot -long new beam to support the 14 foot ceiling joists is structurally adequate. Item #3: It is structurally acceptable to use (2) 2X6 ceiling joists @ 16" on center to support the new vertical 2X4's supporting the 2X rafters above. Due to the difference in spacing between the rafters and ceiling joists, it will be necessary to add a 4X4 over the ceiling joists to catch the new 2X vertical members. Item #4: It is structurally acceptable to add a new 4X10 over the existing new eight -foot -wide window supporting a tributary area of four feet of roof and ceiling load. Item #S: It is structurally acceptable to add a new 4X10 over the new eight -foot -long window at the northwest wall of the residence. ADDITIONAL STRUCTURAL RECOMMENDATIONS • All new wood framing shall be Hem -Fir # 1 unless otherwise noted. • The center wall double top plate needs to be made continuous with normal framing. • All non-standard or substandard wood framing needs to be repaired. • There needs to be a minimum of six inches of vertical clearance between the exterior wall bottom sill plate and the top of finish grade. Adjust the existing finish grade as necessary to accomplish this, grading the finish grade away grom the residence to create positive drainage. • If structural conditions are found in the field that differ from the information stated above, please contact McCann Structural Solutions for guidance before proceeding with any repairs McCann Structural Solutions makes no stated or implied warranties or claims beyond what is contained in this document. No destructive testing was used during the review process. McCann Structural Solutions will not be held liable for structural conditions not directly observed or observable. Only the dames, j stated area of concern was observed during the site visit. "Ps . P_M'11 Sincerely, Michael P. McCann, PE, #18311 Attachments: 6 Photos and Page of 5 —own Page of j ww+c t3CAy)k top a� I Te?K -fl Page of 5 4 Page of 5 STRUCTURAL CALCULATIONS/SKETCHES MS2 McCann Structural Solutions CIVIL & STRUCTURAL ENGINEERING 4621 West View Drive Everett, WA 98203 OFFICE: (425) 879-7949 MICHAEL P. MCCANN P.E., & E. Email: miguared43iiyahoo.com WA Web: http://Mmcenginetring.tripod.con Proect: Z� � Date„ V 2 y Pa C� v Subject: / � B Project o: N,o�S o� 9 r S v�- - 45 � /,50 )/,.. - Z?94­t� 66,A) f S1 14 � / Awr— /VM Pry 3&-t /13 G-3�Z�.�) S,7G AS O dy—`00' /o,/S , X STRUCTURAL CALCULATIONS/SKETCHES 2 McCann Structural Solutions 4621 West View Drive M S-1 CIVIL & .STRUCTURAL ENGINEERING Everett, WA 98203 UICHAEL P. AICCANN P. E.. S. E. OFFICE. (423) 879-7949 WA Email: qDquared484i•r(!!oo ew IVeb: http:Ilmmcengineering.tripod.com Pro Date/ � PA i.� Subject: By: Project No: M-- 2 L �r 1 36Y /13&-57 23D 6) STRUCTURAL CALCULATIONS/SKETCHES McCann Structural Solutions 4621 west View Drive M IS-12 CIVIL & STRUCTURAL ENGINEERING Everett. wA 9820.E MICHAEL P. MCCANN P. E.. S.E. OFFICE: t423) 879-7949 Email: M-W#4a y148 it 1whoo.cuui WA Web: hap •:'.hnmcengineering. tripod. cam Proje,ct-� Date^ P subject: Br Project No: STRUCTURAL CALCULATIONS/SKETCHES McCann Structural Solutions 4621 West View Drive MIS2 CIVIL & STRUCTURAL ENGINEERING Everett, WA 98203 MICHAEL P. MCCANN P.E., S E. OFFICE(425) 879-7949 WA Email: msguared48i6,vhoo.com Web: htip.11mmcengineering.tripod.com P mot: � Date: Q Pa ��-��i,Gv Subject: By: Project No: 7 eIZ )e Cc�uav� S� 050,G ✓= 000, GOI 4- 7 ' X- - , • J STRUCTURAL CALCULATIONS/SKETCHES McCann Structural Solutions 4621 West View Drive MS2 CIVIL & STRUCTURAL ENGINEERING Everett, WA 98203 OFFICE: (425) 879-7949 MICHAEL P. MCCANN P.E., S.E. WA Email: »�uared48,46whoo,com Web: http:!/mmcengineerfng.tripod.com Project: Date, Page Subject: IAvG. By: Aft Project N +/� 65 90" Sc OwPaz