Loading...
REVIEWED BLD2024-0662+Structural_Calculations+5.16.2024_12.35.41_PM+4262237BCINVESTIGATIVE ENGINEERS, LLC RESPONSIVE • ACCURATE • THOROUGH Project Information LIC# : KW-06014804, Build:20.23.08.30 RECEIVED Project Title: Bower Fire Damage Restoration Engineer: Jesse Binford, PE May 17 2024 Project ID: 24029 L CITY OF EDMONDS Project Descr: DEVELOPMENT SERVICES BLD2024-0662 DEPARTMENT Project File: Calcs (24029).ec6 BC Investigative Engineers (c) ENERCALC INC 1983-2023 Project Title : Bower Fire Damage Restoration Description I D : 24029 Address : 22414 72nd Place West, Edmonds, WA 98026 Project Leader : Jesse Binford, PE Phone : 253-833-5557 Fax eMail : jbinford@bcie.net Project Notes Fire damage to majority of roof framing, exterior wall siding/sheathing @ main entry, and all interior finishes and fixtures Significant damage per IEBC requried full engineering anlaysis New trusses were designed, along with lateral improvements where deficient. Carport being rebuilt due to deficiciencies with posts and footings REVIEWED BY CITY OF EDMONDS N BCINVESTIGATIVE ENGINEERS, LLC RES P 0 N G_I VE % -!�A TE •_TH 0 R G Ll G_H Project Title: Bower Fire Damage Restoration Engineer: Jesse Binford, PE Project ID: 24029 Project Descr: Client Information LIC# KW-06014804. Build 20.23 08 30 BC Investigative Engineers Client Company : Paul Davis Restoration Address : 15004 35th Avenue West, Suite A, Lynwood, WA 98087 Phone : 425-409-7085 Fax : Contact : Chris Hill Alternate Contact Client Notes eMail : Project File: Calcs (24029).ec6 (c) ENERCALC INC 1983-2023 Project Title: Bower Fire Damage Restoration Engineer: Jesse Binford, PE INVESTIGATIVE Project ID: 24029 BCENGINEERS, LLC Project Descr: RES P ON S I V F • A CCU R AT E • T H 0 R 0 N G H Building Code Information Project File: Calcs (24029).ec6 LIC# KW-06014804, Build:2023.08.30 BC Invesngative Engineers (6) ENERCALC INC 1983-2023 Governing Code IBC 2021, ASCE 7-16, AISC 360-16, NDS 2018, ACI 318-19, TMS 402-16 City Jurisdiction City of Edmonds Contact Name Alternate Contact Building Official Address Phone Fax eMail Notes : IEBC and IRC Used Project Title: Bower Fire Damage Restoration BC INVESTIGATIVE Engineer: Jesse Binford, PE Project ID: 24029 ENGINEERS, LLC Project Descr: R F.: SIVF AC CLI RATE TH 0R 0 LI GI Project Load Group Builder Project File: Calcs (24029).ec6 LIC# : KVV-06014804, BuIld:20.23.0B.30 BC Investigative Engineers (c) ENERCALC INC 1983-2023 Load Group: Roof Component Name Dead Roof Live Live Snow Wind Seismic Earth Dead 12.000 Snow 25.000 Load Totals (PSF) 12.000 25.000 Load Group : Floor Component Name Dead Roof Live Live Snow Wind Seismic Earth Dead 12.000 Live 40.000 Load Totals (PSF) 12.000 40.000 Load Group : Walls Component Name Dead Roof Live Live Snow Wind Seismic Earth Dead 10.000 Load Totals (PSF) 10.000 BCINVESTIGATIVE ENGINEERS, LLC R i R P 0 N S I V F • A C C 11 R A T E • T H 0 R 0 0 G H Project Title: Bower Fire Damage Restoration Engineer: Jesse Binford, PE Project ID: 24029 Project Descr: ASCE 7-16 Seismic Base Shear Project File: Calcs (24029).ec6 LICX :-06014804, Build:20.23.08.30 BC Investigative Engineers (c) ENERCALC INC 1983.2023 DESCRIPTION: Seismic Base Shear Analysis Specific Description: Bower (24029) Risk Category Calculations per ASCE 7-16 Risk Category of Building or Other Structure "II" : All Buildings and other structures except those listed as Category SCE 7-16, Page 4, Table 1.5-1 I, III, and IV Seismic Importance Factor = 1 ASCE 7-16, Page 5, Table 1.5-2 Gridded Ss & S1values from ASCE 7-16 ASCE 7-16 11.4.2 Max. Ground Motions, 5% Damping SS = 1.280 g, 0.2 sec response Latitude 47 796 deg North S 1 = 0.4502 g, 1.0 sec response Longitude = 122.331 deg West For the closest datapoint grid location ... Latitude = 47.800 deg North Longitude = 122.330 deg West Site Class, Site Coeff. and Design Category Classification: "D" : Shear Wave Velocity 600 to 1,200 ft/sec = D (Based on Testing) Site Coefficients Fa & Fv Fa = 1.00 (using straight-line interpolation from table val Fv = 1.85 Maximum Considered Earthquake Accelerat SMs = Fa * Ss = 1.280 SM1 = Fv"S1 = 0.833 Design Spectral Acceleration SDS= SMS z 2/3 = 0.853 S D1 = SM1 * 2/3 = 0.555 Seismic Design Category = D Resisting System Basic Seismic Force Resisting System ... Bearing Wall Systems 17.Light-framed walls with shear panels of all other materials Response Modification Coefficient " I = 2.00 Building height Limits : System Overstrength Factor " Wo " = 2.50 Category "A & B" Limit: No Limit Deflection Amplification Factor " Cd ' = 2.00 Category "C" Limit: No Limit Category "D" Limit: Limit = 35 NOTE! See ASCE 7-16 for all applicable footnc Category "E" Limit: Not Permitted Category "F" Limit: Not Permitted ASCE 7-16 Table 20.3-1 ASCE 7-16 Table 11.4-1 & 11.4-2 ASCE 7-16 Eq. 11.4-1 ASCE 7-16 Eq. 11.4-2 ASCE 7-16 Eq. 11.4-3 ASCE 7-16 Eq. 11.4-4 tSCE 7-16 Table 11.6-1 & -2 ASCE 7-16 Table 12.2-1 Lateral Force Procedure ASCE 7-16 Section 12.8.2 Equivalent Lateral Force Procedure The "Equivalent Lateral Force Procedure" is being used according to the provisions of ASCE 7-16 12.8 Determine Building Period Use ASCE 12.8-7 Structure Type for Building Period CalcuIEAll Other Structural Systems " Ct " value = 0.020 " hn " : Height from base to highest leve 12.0 ft " x " value = 0.75 " Ta " Approximate fundemental period using Eq. 12.8-7 : Ta = Ct " (hn A x) = 0.129 sec "TL" : Long -period transition period per ASCE 7-16 Maps 22-14 -> 22-17 6.000 sec Building Period " Ta " Calculated from Approximate Method self= 0.129 Cs " Response Coefficient ASCE 7-16 Section 12.8 1.1 SIDS: Short Period Design Spectral Response = 0.853 From Eq. 12.8-2, Preliminary Cs = 0.427 " R " : Response Modification Factor n 2.00 From Eq 12.8-3 & 12.8-4 , Cs need not excee = 2.153 " I " : Seismic Importance Factor = 1 From Eq 12.8-5 & 12.8-6, Cs not be less than = 0.038 Cs: Seismic Response Coefficient = = 0.4267 J �� Project Title: Bower Fire Damage Restoration INVESTIGATIVE Engineer: Jesse Binford, PE ]UNIV ENGINEERS, LLC Project De 24029 Project scr: RESP0 N SIVE. - ACCN RATE - T H 0 R0 LIGH ASCE 7-16 Wind Forces Chpt 28, Pt2 & Chpt 30, Pt2 Project File: Calcs (24029).ec6 LIC# KW-o6o14804, BuiId2023.08.30 BC Investigative Engineers (c) ENERCALC INC 1983-2023 DESCRIPTION: Bower (24029) General Design Values Calculations per ASCE 7-16 V : Basic Wind Speed per Sect 26.5-1 or 2 97.0 mph User specified minimum design pressu 8 0 psf Occupancy per Table 1.5-1 II All Buildings and other structures except those listed Exposure Category per 26.7 Exposure B Topographic Factor Kzt per 26.8 1.00 Main Force Resisting System Valu Component & Cladding Values MRH : Mean Roof Height 12.0 ft Effective Wind Area of Component & Clad. 10.0 ftA2 Roof Slope Angle 20 degrees Roof pitch for cladding pressu Flat/Hip/Gable Roof LHD : Least Horizontal Dimension 26.0 ft a = max (0.04 * LHD, 3, min(0.10 * LHD, 0.4*MRH)) 3 00 ft Lambda MWFRS: per Figure 26. 1.00 Lambda Component & Cladding : per Figure 0 82 Design Wind Pressures Horizontal Pressures Zone: A = .psf Zone: C = .psf -8 Zone: B = -B.00 00 psf Zone: D = -8-8.0000 psf Vertical Pressures r Zone: E = -17.96 psf Zone G = _ -12 52 psf Zone: F = -12.52 psf Zone H = -9 50 psf Overhangs ... Zone: Eoh = -25.14 psf Zone: Goh = -19 64 psf ASCE 7-16 Section 28.5.4 Minimum Design Wind Loads requires that the load effects of the design wind pressures from Section 28.5.3 shall not be less than a minimum load defined by assuming the pressures, ps, for zones A and C equal to +16 psf, Zones B and D equal to +8 psf, while assuming ps for Zones E, F, G, and H are equal to 0 psf. Component & Cladding Design Wind Pres: Roof Pressures Positive Negative Zone 1 *** *** psf Zone 1' *** *** psf Zone 2 *** *** psf Zone 2e *** *** psf Zone 2n *** *** psf Zone 2r *** *** psf Zone 3 *** *** psf Zone 3e *** *** psf Zone 3r *** *** psf Wall Pressures Wall Zone 4 *** *** psf Wall Zone 5 *** *** psf Design Wind Pressure = Lambda * Kzt * Ps30 pe Overhang Pressures Negative Zone 1 *** psf Zone 1' *** psf Zone 2 *** psf Zone 2e *** psf Zone 2n *** psf Zone 2r *** psf Zone 3 *** psf Zone 3e *** psf Zone 3r *** psf '*** There is no value in Figure 30.4-1 Tabular Values 0149 PC---VO,C)eS� MIS! Em �AlP wl �f �C lllll�lqp� ------ IS hi III [I willimililill W11MC ws= p 61.1 Sw a (-I - -t( -, PD* (O(M)i O�VD)l) �y t�t,�-p (�t6) i- t'6(aw?') -- r-6 To (2�G25)(i�) 4�5Dd ewe 0 Tl -, c s az� ((rf6s) LOA IP m t�K-ST21 COMBO o o + i��(ZJ � 16Z� �CZi. - pc�-15 4 two -c5LP) coil t3 cP�m31 OF WWI 1-7 U 253.833.5557 (0) Project No. Sheet of INVESTIGATIVE ENGINEERS , LLC RESPONSIVE • ACCURATE • THOROUGH 253.833.7309 M 888.335.5557 (T) 3605 C STREET N.E. AUBURN, WA. 98002 Designer Date Checked By Date Revisions Date 41101 D_3G . . . .............. — ----- roll 20 1 S< �OD -, W) 4\je(vo �Z_ CAUSE &ORIGIN • RESTORATION DESIGN -DUE DILIGENCE • CONSTRUCTION DEFECT • STRUCTURAL CONSULTINGISEISMIC REHABILITATION -CODE ANALYSIS FOR: TITLE: BCIEJOB NO. 253.833.5557 (0) Project No. Sheet of INVESTIGATIVE 253.833.7309 (F) I)csigner Date ENGINEERS , LLC 888.335.5557 (T) 3605 C STREET N.E. Checked By Date RESPONSIVE • ACCURATE • THOROUGH AUBURN, WA.98002 Re-isions Date L�I�I��Pz7 4A )41#4 Cp)� tw; 17�io t a) -7q'p'J L,w'D�- T lGob �d 1 t 012)�- 0,5 CAUSE &ORIGIN • RESTORATION DESIGN • DUE DILIGENCE• CONSTRUCTION DEFECT • STRUCTURAL CONSULTINGISEISMIC REHABILITATION • CODE ANALYSIS FOR: TITLE: I BCIEJOB NO. BINVESTIGATIVE ENGINEERS, LLC R F S P O N S I V F • A C C I I R A T E • T H U R G U G H Wood Beam LIC# KW-06014804, 1301d:20 23.08.30 DESCRIPTION: [H1] CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : IBC 2021 Material Properties Analysis Method : Allowable Stress Design Load Combination IBC 2021 Wood Species Douglas Fir -Larch Wood Grade No.1 Project Title: Bower Fire Damage Restoration I Z Engineer: Jesse Binford, PE 1 Project ID: 24029 Project Descr: Project File: Calcs (24029).ec6 BC Investlgabve Engineers (c) NERCALC INC 1983-2023 Beam Bracing : Beam is Fully Braced against lateral -torsional buckling Fb + Fb - Fc - Prll Fc - Perp Fv Ft 0(0 1561 S(0.325) 48 Span = 6.0 ft 1000 psi E : Modulus of Elasticity 1000 psi Ebend- xx 1700 ksi 1500 psi Eminbend - xx 620 ksi 625 psi 180 psi 675 psi Density 31.21 pcf c Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.1560, S = 0.3250 , Tributary Width = 1.0 ft, (ROOF) DESIGN SUMMARY :Maximum Bending Stress Ratio = 0.5671 Maximum Shear Stress Ratio Section used for this span 4x8 Section used for this span fb: Actual = 847.12psi fv: Actual F'b = 1,495.00psi F'v Load Combination +D+S Load Combination Location of maximum on span = 3.000ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.050 in Ratio = 1427>=240 Span: 1 : S Only Max Upward Transient Deflection 0 in Ratio = 0 <240 n/a Max Downward Total Deflection 0.075 in Ratio = 964 -180 Span: 1 : +D+S Max Upward Total Deflection 0 in Ratio = 0 <180 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress a ios omen a ues Segment Length Span # M V CD CM Ct CLx CF Cfu C i C r D Only Length = 6.0 ft 1 0.235 0.137 0.90 1.00 1.00 1 00 1.300 1.00 1.00 1 00 +D+S 1 00 1.00 1.00 1 300 1 00 1.00 1 00 Length = 6.0 ft 1 0.567 0.331 1.15 1.00 1.00 1.00 1.300 1.00 1.00 1.00 +D+0.750S 1.00 1.00 1.00 1.300 1.00 1.00 1.00 Length = 6.0 ft 1 0.471 0 275 1 15 1.00 1.00 1 00 1 300 1 00 1.00 1.00 +0.601D 1 00 1.00 1 00 1.300 1 00 1.00 1.00 Length = 6 0 ft 1 0.079 0.046 1 60 1.00 1.00 1.00 1.300 1.00 1.00 1.00 0.331 1 4x8 68.49 psi 207.00 psi +D+S 0.000 ft Span # 1 ear a ues M fb F'b V fv F'v 00 0.00 0.0 0.0 0.70 274.7 1,170 0 0.38 22.2 162.0 0.0 0.00 00 0.0 2.16 8471 1,495.0 1.16 68.5 207.0 0.0 0.00 0.0 0.0 1.80 704.0 1,495.0 0.96 56.9 2070 0.0 0.00 0.0 0.0 0.42 164 8 2,080.0 0.23 13.3 2880 Project Title: Bower Fire Damage RestorationEnineC3 r: Jesse INVESTIGATIVE Pro ect ID: 240296inford, PE BCENGINEERS, LLC Project Descr: RESPONSIVE • ACCIJ RA TE • THOROUGH Wood Beam DESCRIPTION: [H1] Overall Maximum Deflections Project File: Calcs (24029).ec6 Load Combination Span Max. "" Defl Location in Span Load Combination Max...+" ueT1 Location in bpan +D+S 1 0.0747 3.022 0.0000 0.000 Vertical Reactions Load Combination Max Upward from all Load Conditions Max Upward from Load Combinations Max Upward from Load Cases D Only +D+S +D+0.750S +0.60D S Only Support notation : Far left is #1 Values in KIPS Support 1 Support 2 1.443 1.443 1.443 1.443 0.975 0.975 0.468 0.468 1.443 1.443 1.199 1.199 0.281 0.281 0.975 0.975 BINVESTIGATIVE ENGINEERS, LLC Project Title: Engineer: Project ID: Project Descr: RESPONSIVE • A C C 11 RATE Wood Beam LIC : KW-06014804, Build:20.23.08.30 BC Investigative Engineers DESCRIPTION: [H1] - SIM CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Fb + Load Combination IBC 2021 Fb - Fc - Prll Wood Species Douglas Fir -Larch Fc - Perp Wood Grade No 1 Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling 4x8 Span =6.0ft r Bower Fire Damage Restoration Jesse Binford, PE 24029 Project File: Calcs (24029).ec6 (C) ENERCALC INC 1983-2023 1,000.0 psi E : Modulus of Elasticity 1,000.0psi Ebend-xx 1,700.Oksi 1,500 0 psi Eminbend - xx 620.0 ksi 625.0 psi 180 0 psi 675.0psi Density 31.210pcf D(0.78) (1 625) D(0.156) S(0.325) e A lied Loads Service loads entered. Load Factors will be applied for calculations. PP Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.1560, S = 0.3250 k/ft, Extent = 4.0 --» 6.0 ft, Tributary Width = 1.0 ft, (ROOF) Uniform Load : D = 0.0360, S = 0.0750 k/ft, Extent = 0.0 --» 4.0 ft, Tributary Width = 1.0 ft, (ROOF) Point Load : D = 0.780, S = 1.625 k @ 4.0 ft, ([PHGT1]) DESIGN SUMMARY Maximum Bending Stress Ratio = 1.0821 Maximum Shear Stress Ratio = Section used for this span 4x8 Section used for this span fb: Actual = 1,617.29psi fv: Actual = F'b = 1,495.00psi F'v = Load Combination +D+S Load Combination Location of maximum on span = 4 007ft Location of maximum on span = Span # where maximum occurs = Span # 1 Span # where maximum occurs = Maximum Deflection Max Downward Transient Deflection 0.079 in Ratio = 910> 240 Span: 1 S Only Max Upward Transient Deflection 0 in Ratio = 0 <240 n/a Max Downward Total Deflection 0.117 in Ratio = 615>=180 Span: 1 +D+S Max Upward Total Deflection 0 in Ratio = 0 <180 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios omen a ues Segment Length Span # M V CD CM Ct CLx CF Cfu C i C r M D Only Length = 6.0 ft 1 0.448 0.268 0.90 1.00 1 00 1.00 1.300 1.00 1.00 1.00 1.34 +D+S 1.00 1.00 1.00 1.300 1.00 1.00 1 00 Length = 6.0 ft 1 1 082 0.648 1.15 1.00 1.00 1.00 1.300 1.00 1.00 1 00 413 +D+0.750S 1.00 1.00 1.00 1.300 1.00 1.00 1.00 Length = 6.0 ft 1 0.899 0.538 1 15 1.00 1.00 1.00 1.300 1.00 1.00 1 00 3.43 +0 60D 1 00 1.00 1 00 1.300 1 00 1.00 1.00 Length = 6.0 ft 1 0 151 0 091 1.60 1 00 1.00 1 00 1.300 1.00 1 00 1.00 0.80 fb F'b 0.0 524.5 1,170 0 0.0 1,617 3 1,495.0 00 1,344.1 1,495.0 0.0 314.7 2,080.0 0.648 :1 4x8 134.11 psi 207.00 psi +D+S 5.409 ft Span # 1 ty Shear Values V fv F'v 0.00 0.0 00 0.74 43.5 162.0 0.00 0.0 00 2.27 134.1 2070 000 0.0 0.0 1.89 111.5 207.0 0.00 0.0 0.0 0.44 26.1 288.0 BCINVESTIGATIVE ENGINEERS, LLC R ES PO NS I V F • AC C IJRA TE • TH0R_GU GH Project Title: Bower Fire Damage Restoration �///� Engineer: Jesse Binford, PE Project ID: 24029 Project Descr: Wood Beam Project File: Calcs (24029).ec6 DESCRIPTION: [H1] - SIM Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+S 1 0.1170 3.241 0.0000 0.000 Vertical Reactions Load Combination Max Upward from all Load Conditions Max Upward from Load Combinations Max Upward from Load Cases D Only +D+S +D+0.750S +0.60D S Only Support notation : Far left is #1 Values in KIPS Support 1 Support 2 1.258 2.553 1.258 2.553 0.850 1.725 0.408 0.828 1.258 2.553 1.046 2.122 0.245 0.497 0.850 1.725 BCINVESTIGATIVE ENGINEERS, LLC RESPONSIVE • A CC-1-1 RATE • T H O R O U G H Wood Beam LIC#t KW-06014804, Bdfk20.23.08.30 DESCRIPTION: [H2] CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Load Combination IBC 2021 Wood Species Douglas Fir -Larch Wood Grade No.1 Beam Bracing : Beam is Fully Braced against lateral -torsional buckling Project Title: Bower Fire Damage Restoration Engineer: Jesse Binford, PE Project ID: 24029 Project Descr: Fb + Fb - Fc - Prll Fc - Perp Fv Ft D(0.1561S(0.325) y 48 Span = 8.0 ft Project File: Calcs (24029).ec6 1,000.0 psi E : Modulus of Elasticity 1,000.0 psi Ebend- xx 1,700.0 ksi 1,500.0 psi Eminbend - xx 620.Oksi 625.0 psi 180.0 psi 675.0psi Density 31210pcf Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.1560, S = 0.3250 , Tributary Width = 1.0 ft, (ROOF) DESIGN SUMMARY Maximum Bending Stress Ratio = 1.007 1 Maximum Shear Stress Ratio Section used for this span 4x8 Section used for this span fb: Actual = 1,505.99psi fv: Actual F'b = 1,495.00psi F'v Load Combination +D+S Load Combination Location of maximum on span = 4.000ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.159 in Ratio = 602 > 240 Span: 1 S Only Max Upward Transient Deflection 0 in Ratio = 0 <240 n/a Max Downward Total Deflection 0.236 in Ratio = 406>=180 Span: 1 +D+S Max Upward Total Deflection 0 in Ratio = 0 <180 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress -Ratios Moment values Segment Length Span # M V CD CM Ct CLx CF Cfu C i C r M fb F'b D Only 0.0 Length = 8.0 ft 1 0 417 0.194 0.90 1 00 1.00 1 00 1.300 1.00 1.00 1.00 1.25 488.4 1,170 0 +D+S 1.00 1.00 1.00 1.300 1 00 1.00 1.00 0.0 Length = 8.0 ft 1 1.007 0.469 1.15 1.00 1.00 1.00 1 300 1.00 1.00 1 00 3.85 1,506.0 1,495.0 +D+0.750S 1.00 1.00 1.00 1.300 1.00 1.00 1.00 0.0 Length = 8.0 ft 1 0.837 0.390 1 15 1.00 1.00 1.00 1.300 1.00 1.00 1.00 3.20 1,251.6 1,495.0 +0.60D 1.00 1.00 1.00 1.300 1.00 1.00 1.00 0.0 Length = 8.0 ft 1 0 141 0.066 1.60 1.00 1.00 1.00 1.300 1.00 1.00 1.00 0.75 293.1 2,080.0 0.469 :1 4x8 97.13 psi 207.00 psi +D+S 7.416 ft Span # 1 Shear a uV- es V fv F'v 0.00 0.0 0.0 0.53 31.5 162.0 0.00 0.0 0.0 1.64 97.1 207.0 0.00 0.0 0.0 1.37 80.7 207.0 0.00 0.0 0.0 032 189 288.0 Project Title: Bower Fire Damage Restoration Engineer: Jesse Binford, PE INVESTIGATIVE p Project ID: 24029 BCENGINEERS, LLC Project Descr: RES PO N S I V E • A C C I.I R A T E • T H O ROUG 6 Wood Beam Project File: Calcs (24029).ec6 LIC# - KW 06014804, Build:20.23.08.30 BC Investigative Engineers (c) ENERCALC C 1983-2023 DESCRIPTION: [H2] Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+S 1 0.2360 4.029 0.0000 0.000 Vertical Reactions Load Combination Max Upward -from Load Conditions Max Upward from Load Combinations Max Upward from Load Cases D Only +D+S +D+0.750S +0.60D S Only Support notation : Far left is #1 Values in KIPS Support 1 Support 2 1.924 1.924 1.924 1.924 1.300 1.300 0.624 0.624 1.924 1.924 1.599 1.599 0.374 0.374 1.300 1.300 Project Title: Bower Fire Damage Restoration BC INVESTIGATIVE Engineer: Jesse Binford, PE Project ID: 24029 ENGINEERS, LLC Project Descr: RESPCN SIVF • ACCII RATE • TH CRC LIG H Wood Beam Project File: Calcs (24029).ec6 DESCRIPTION: [131] CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Fb + Load Combination IBC 2021 Fb - Fc - Prll Wood Species Hem -Fir Fc - Perp Wood Grade No.2 Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0.108) S(0.225) Dj0.108) S(0.225) D(0 54) 4x8 Span = 7.50 ft 4x8 850 psi 850 psi 1300 psi 405 psi 150 psi 525 psi E : Modulus of Elasticity Ebend-xx 1300ksi Eminbend - xx 470ksi Density 26.84pcf D(0.036) S(0.075) 4x8 Span = 7 D ft Span = 6.50 ft A Had Loads Service loads entered. Load Factors will be applied for calculations. pp Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.1080, S = 0.2250 , Tributary Width = 1.0 ft, (ROOF) Load for Span Number 2 Uniform Load: D = 0.1080, S = 0.2250 k/ft, Extent = 0.0 - > 5.50 ft, Tributary Width = 1.0 ft, (ROOF) Uniform Load : D = 0.0360, S = 0.0750 k/ft, Extent = 5.50 -->> 7.0 ft, Tributary Width = 1.0 ft, (ROOF) Point Load: D = 0.540, S = 1.125 k @ 5.50 ft, ([PHGT3]) Load for Span Number 3 Uniform Load : D = 0.0360, S = 0.0750 , Tributary Width = 1.0 ft, (ROOF) DESIGN SUMMARY ' ' • Maximum Bending Stress Ratio = 0.901: 1 Maximum Shear Stress Ratio = 0.855 : 1 Section used for this span 4x8 Section used for this span 4x8 fb: Actual = 916.07psi fv: Actual = 118.02 psi Pb = 1,016.60psi F'v = 138.00psi Load Combination +D+S Load Combination +D+S Location of maximum on span = 7.500ft Location of maximum on span = 6.412 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 2 Maximum Deflection Max Downward Transient Deflection 0.049 in Ratio = 1823-240 Span: 2: S Only Max Upward Transient Deflection -0.016 in Ratio = 5013>=240 Span: 3: S Only Max Downward Total Deflection 0.073 in Ratio = 1232 -180 Span: 2: +D+S Max Upward Total Deflection -0.023 in Ratio = 3387>=180 Span: 3 : +D+S Maximum Forces & Stresses for Load Combinations Load Combination max ress a ios Moment Values bhearValues Segment Length Span # M V CD CM Ct CLx CF Cfu C i C r M fb F'b V fv F'v D Only 0.0 0.00 0.0 0.0 Length = 7 50 ft 1 0.373 0.249 0.90 1.00 1.00 1.00 1.300 1.00 080 1 00 0.76 297.1 795.6 0.46 26.9 108.0 Length = 7.0 ft 2 0.373 0.354 0.90 1.00 1.00 1.00 1.300 1.00 0.80 1 00 0.76 297.1 7956 0.65 38.3 108.0 Length = 6.50 ft 3 0 245 0.354 0.90 1.00 1.00 1.00 1.300 1.00 0.80 1 00 0.50 195.3 7956 0.17 38.3 1080 Project Title: Bower Fire Damage Restoration l ABI INVESTIGATIVE Engineer: Jesse Binford, PE Project ID: 24029 ENGINEERS, LLC Project Descr: R E S P 0 N S I V F • A C C 11 R A T F • T H 0 R r Wood Beam Project File: Calcs (24029).ec6 LICS : KUV-06014804. Build:20.23.08.30 SC Investigative Engineers (c) ENERCALC INC 1983-2023 DESCRIPTION: [131] Maximum Forces & Stresses for Load Combinations Load Combination max Stress rtatios Segment Length Span # M V CD CM Ct CLx Cf, +D+S 1.00 1.00 1.00 1 300 Length = 7.50 ft 1 0.901 0.602 1.15 1.00 1.00 1.00 1.300 Length = 7.0 ft 2 0.901 0.855 1.15 1.00 1.00 1.00 1.300 Length = 6.50 ft 3 0.592 0.855 1 15 1.00 1 00 1.00 1.300 +D+0.750S 1.00 1.00 1 00 1.300 Length = 7.50 ft 1 0.749 0.500 1.15 1.00 1.00 1.00 1.300 Length = 7.0 ft 2 0.749 0.711 1 15 1.00 1.00 1.00 1.300 Length = 6.50 ft 3 0.492 0.711 1.15 1.00 1 00 1.00 1.300 +0.60D 1.00 1.00 1.00 1.300 Length = 7.50 ft 1 0.126 0 084 1.60 1.00 1.00 1.00 1.300 Length = 7.0 ft 2 0.126 0 120 1.60 1.00 1.00 1.00 1.300 Length = 6.50 ft 3 0.083 0.120 1.60 1 00 1.00 1.00 1.300 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span +D+S 1 0 0730 3 214 +D+S 2 0 3 0 Vertical Reactions Load Combination Max Upward from all Load Conditions Max Upward from Load Combinations Max Upward from Load Cases D Only +D+S +D+0.750S +0.60D S Only .0654 4.118 .0000 4.118 +D+S Support notation : Far left is #1 Support 1 Support 2 Support 3 Support 4 0.937 3.162 2.659 0.124 0.937 3.162 2.659 0.124 0.633 2.137 1797 0.084 0.304 1.026 0.862 0.040 0.937 3.162 2.659 0.124 0.778 2.628 2.210 0103 0182 0.615 0.517 0.024 0.633 2.137 1.797 0.084 Moment a ues ear a ues _ Cfu C i C r M fb F'b V fv F'v 1.00 0.80 1.00 0.0 0.00 0.0 0.0 1.00 080 1.00 2.34 916.1 1,016.6 1 41 83 1 138.0 1.00 0.80 1.00 2.34 9161 1,016.6 2.00 118.0 138.0 1.00 0.80 1.00 1.54 602.0 1,016.6 0.53 118.0 138.0 1.00 0.80 1.00 0.0 0.00 0.0 0.0 1.00 0.80 1.00 195 761.3 1,016.6 1.17 69.0 138.0 1 00 0.80 100 1.95 761.3 1,016.6 1.66 98.1 138.0 1.00 0.80 1.00 1.28 500.3 1,016.6 0.44 98.1 138.0 1.00 0.80 1.00 0.0 0.00 00 0.0 1.00 0.80 1.00 046 178.3 1,414.4 027 16.2 192.0 1.00 080 1.00 0.46 178.3 1,414.4 0.39 23.0 192.0 1.00 080 1.00 0.30 117.2 1,414.4 010 23.0 192.0 Load Combination Max. "+" Defl Location in Span 0.0000 0.000 0.0000 0.000 -0.0230 2.076 Values in KIPS Project Title: Bower Fire Damage Restoration INVESTIGATIVE Engineer: Jesse Binford, PE BC Project ID: 24029 ENGINEERS, LLC Project Descr: R E S P G N S I V F • ACCURATE • THOROUGH Wood Beam Project File: Calcs (24029).ec6 LIC# : KW-06014804, BuiId:20.23.OB.30 BC Investigative Engineers (c) ENERCALC INC 1983-2023 DESCRIPTION: [132] CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Fb + 1400 psi E : Modulus of Elasticity Load Combination IBC 2021 Fb - 1400 psi Ebend- xx 1600ksi Fc - Prll 1500 psi Eminbend - xx 580 ksi Wood Species Hem -Fir Fc - Perp 405 psi Wood Grade Select Structural Fv 150 psi Ft 925 psi Density 26 84 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0.048) S(0.1) - 410 Span = 17.50 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0480, S = 0.10 , Tributary Width = 1.0 ft, (ROOF) DESIGN SUMMARY Maximum Bending Stress Ratio = 0.881: 1 Maximum Shear Stress Ratio Section used for this span 4x10 Section used for this span fb: Actual = 1,362.16psi fv: Actual F'b = 1,545.60psi F'v Load Combination +D+S Load Combination Location of maximum on span = 8.750ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.605 in Ratio = 347> 240 Span: 1 : S Only Max Upward Transient Deflection 0 in Ratio = 0 <240 n/a Max Downward Total Deflection 0.895 in Ratio = 234 -180 Span: 1 : +D+S Max Upward Total Deflection 0 in Ratio = 0 <180 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress-Ra ios Segment Length Span # M V CD CM Ct CLx CF Cfu D Only Length = 17.50 ft 1 +D+S Length = 17.50 ft 1 +D+0.750S Length = 17.50 ft 1 +0.60D Length = 17.50 ft 1 Moment Va-ues Ci Cr M 0.365 0.164 0.90 1.00 1.00 1.00 1 200 1.00 0.80 1.00 1.00 1.00 1.00 1.200 1.00 080 1.00 0.881 0.397 1.15 1.00 1.00 1.00 1.200 1.00 0.80 1.00 1.00 1.00 1.00 1.200 1.00 0.80 1.00 0.732 0.330 1.15 1 00 1.00 1.00 1.200 1.00 0.80 1 00 1 00 1.00 1.00 1.200 1.00 0.80 1 00 0123 0.055 1.60 1 00 1.00 1 00 1.200 1 00 0.80 1 00 1.84 567 4.71 1.10 0.397 :1 4x10 = 54.74 psi 138.00 psi +D+S 0.000 ft Span # 1 fb Fb 0.0 441.8 1,209.6 0.0 1,362.2 1,545.6 0.0 1,132 1 1,545 6 00 265 1 2,150.4 Shear a ues V fv F'v 0.00 0.0 0.0 0.38 17.8 108.0 0.00 0.0 0.0 1.18 54.7 138.0 0.00 0.0 0.0 0.98 45.5 138.0 0.00 0.0 00 0.23 107 192.0 Project Title: Engineer: INVESTIGATIVE Project ID: BCENGINEERS, LLC Project Descr: R E S P 0 N S I V F • A r G I I R A T E • T H 0 R 0 0 G H Wood Beam LIC# : KW-06014804. Bulls! 20.23.08.30 BC Investigative Engineers DESCRIPTION: [B2] Bower Fire Damage Restoration Jesse Binford, PE 24029 Project File: Calcs (24029).ec6 (C) ENERCAC INC 1983-2023 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+S 1 0.8953 8.814 0.0000 0.000 Vertical Reactions Load Combination Max Upward from all Load Conditions Max Upward from Load Combinations Max Upward from Load Cases D Only +D+S +D+0.750S +0.60D S Only Support 1 1.295 1.295 0.875 0.420 1.295 1.076 0.252 0.875 Support notation : Far left is #1 Values in KIPS Support 2 1.295 0.875 0.420 1.295 1.076 0.252 0.875 Project Title: Bower Fire Damage Restoration Z1, BC INVESTIGATIVE Engineer: Jesse Binford, PE Project ID: 24029 ENGINEERS, LLC Project Descr: RES PG N S I V F • ACC IJ RA TE • TH GRG ll GH Wood Beam LI # : K:1 14804, Build_20.23.08.30 DESCRIPTION: Copy of [132] CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Fb + Load Combination IBC 2021 Fb - Fc - Prll Wood Species Hem -Fir Fc - Perp Wood Grade No 1 Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0.048) S(0.1) v 412 Span = 17.50 ft Project File: Calcs (24029).ec6 975 psi E : Modulus of Elasticity 975 psi Ebend- xx 1500 ksi 1350 psi Eminbend - xx 550ksi 405 psi 150 psi 625 psi Density 26.84pcf Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load: D = 0.0480, S = 0.10 , Tributary Width = 1.0 ft, (ROOF) DESIGN SUMMARY ' ' • Maximum Bending Stress Ratio = 0.9331 Maximum Shear Stress Ratio = 0.321 : 1 Section used for this span 4x12 Section used for this span 4x12 fb: Actual = 920.89psi fv: Actual = 44.29 psi F'b = 986.70psi F'v = 138.00 psi Load Combination +D+S Load Combination +D+S Location of maximum on span = 8.750ft Location of maximum on span = 0.000 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.359 in Ratio = 585 >=240 Span: 1 S Only Max Upward Transient Deflection 0 in Ratio = 0 <240 n/a Max Downward Total Deflection 0.531 in Ratio = 395 > 180 Span: 1 +D+S Max Upward Total Deflection 0 in Ratio = 0 <180 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios - omen a uVi es ear Values Segment Length Span # M V CD CM Ct CLx CF Cfu C i Cr M fb F'b V fv F'v D Only 0.0 0.00 0.0 0.0 Length = 17.50 ft 1 0.387 0.133 0.90 1.00 1.00 1 00 1.100 1.00 0.80 1.00 1.84 298.7 772.2 0.38 14.4 108.0 +D+S 1.00 1.00 1 00 1.100 1 00 0.80 1.00 0.0 0.00 0.0 0.0 Length = 17.50 ft 1 0.933 0.321 1.15 1.00 1 00 1 00 1.100 1 00 0.80 1.00 5.67 920.9 9867 1.16 44.3 138.0 +D+0.750S 1 00 1 00 1 00 1.100 1.00 0.80 1 00 00 0.00 0.0 0.0 Length = 17.50 ft 1 0.776 0.267 1.15 1 00 1.00 1 00 1.100 1.00 0.80 1.00 4.71 765.3 986.7 0.97 36.8 1380 +0.60D 1 00 1.00 1 00 1.100 1.00 0.80 1 00 0.0 000 0.0 0.0 Length = 17.50 ft 1 0.131 0 045 1 60 1.00 1.00 1 00 1 100 1.00 0.80 1.00 1 10 179.2 1,372.8 0.23 8.6 192.0 (/� Project Title: Bower Fire Damage Restoration INVESTIGATIVE Engineer: Jesse Binford, PE BCENGINEERS, Project ID: 24029 LLC Project Descr: RESPONSIVE • ACCURATE • THOROUGH Wood Beam Project File: Calcs (24029).ec6 LIC# : KW-06014804, Build:20.23.08.30 BC Investigative Engineers (c) ENERCALC INC 1983-2023 DESCRIPTION: Copy of [B2] Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+S 1 0.5308 8.814 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Max Upward from all Load Conditions 1.295 1.295 Max Upward from Load Combinations 1.295 1.295 Max Upward from Load Cases 0.875 0.875 D Only 0.420 0.420 +D+S 1.295 1.295 +D+0.750S 1.076 1.076 +0.60D 0.252 0.252 S Only 0.875 0.875 BCINVESTIGATIVE ENGINEERS, LLC RFSPONSIVF • ACOIIRATF • TH ORO LIGH Pole Footing Embedded in Soil LIC# : KW-06014804. Build:20.23.08.30 DESCRIPTION: [P1]/[P2] OVER [F1]/[F2] Code References Calculations per IBC 2021 1807.3, ASCE 7-16 Load Combinations Used : IBC 2021 General Information Pole Footing Shape Circular 24.0 in Calculate Min Depth for Allowable Pressures No Lateral Restraint at Ground Surface Allow Passive ... ..... 300 0 pcf Max Passive. ............ 1,500.0 psf Controlling Values Governing Load CombinatieD+0.70E Lateral Load 0.2919 k Moment 2 335 k-ft NO Ground Surface Restraint Pressures at 1/3 Depth Actual 344.832 psf Allowable 347.540 psf Minimum Required Depth 3.50 ft Footing Base Area 3.142 ftA2 Maximum Soil Pressure 1.009 ksf Applied Loads Lateral Concentrated Load (k) D : Dead Load k Lr : Roof Live k L : Live k S : Snow k W : Wind k E : Earthquake 04170 k H : Lateral Earth k Load distance above ground surface 80 ft Load Combination Results Load Combination D Only +D+S +D+0.750S +D+0.70E +D+0.750S+0 5250E +0 60D +0 60D+0.70E Project Title: Bower Fire Damage Restoration Engineer: Jesse Binford, PE l Project ID: 24029 Project Descr: Point Load Lateral Distributed Loads (k k/ft k/ft k/ft k/ft k/ft k/ft k/ft TOP of Load above ground surface ft BOTTOM of Load above ground surface ft Project File: Calcs (24029).ec6 0 co Soil Surface _ No lateral restraint Vertical Load (k) 1.030 k k k 2140k k k k Forces @ Ground Surface Required Pressure at 1/3 Depth Soil Increase Loads - (k) Moments - (ft-k) Depth - (ft) Actual - (psf) Allow - (psf) Factor 0 000 0.000 013 0.0 00 1.000 0 000 0 000 013 0.0 0.0 1.000 0.000 0 000 0.13 0.0 00 1.000 0.292 2 335 350 344.8 347.5 1.000 0.219 1 751 325 310.7 312.5 1.000 0.000 0 000 013 00 00 1 000 0.292 2.335 3.50 3448 3475 1.000