APPROVED ENG BLD RESUB 3-BLD2024-0578+Architectural_Plan+8.6.2024_2.34.05_PM+4424489JOSHUAANDEROWNER/CONTACT PERSON: EXISTING MAIN FLOOR PLAN
JOSHUA ANDERSON
206-718-7689
-101- NORTH
PROPERTY ADDRESS:
6830 174TH ST. SW
EDMONDS, WA 98026
11X17 DRAWING
1/4"=1' SCALE
EXISTING HOME 1776 SQ-FT'
PROPOSED ADDITION WILL ADD
AN ADDITIONAL TOTAL 469 SQ-FT'
6-0 1 /2" T-1 1 /2" —
PPROVED
AUST BE
B SITE
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
LEGEND
o DEMO WALLS
2'-6" _rECE
6-1 1 /2" �E 2'-8" � 4'-8 1 /2"
................................................
= The following documentation shall be available on
site for the building inspector:
❑ COE APPROVED ARCHITECTURAL PLAN SET '
❑x COE APPROVED STRUCTURAL PLAN SET
❑ COE REVIEWED CALCULATION PACKET
; ❑ ENERGY CREDIT WORKSHEET
❑ SITE PLAN
❑ CIVIL PLAN i
■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ;
City Of Edmonds
Building Department
IIII II:IVto] :4 SO► [•]O]=
6830 174TH ST SW
ANDERSON
Approved Date 08/ 14/2024
Building Official E1rl c/
Carfe,-r
Permit Number
BLD2024-0578
Applicant shall repair/replace all
damage to utilities or frontage
improvements in City right-of-way
per city standards that is caused or
occurs during the permitted project.
ENGINEERING DIVISION
APPROVED AS NOTED
Jd], tV4d~u 08/14/2024
VV
RESUB
Aug 06 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
OWNER/CONTACT PERSON:
JOSHUA ANDERSON
206-718-7689
PROPSED MAIN FLOOR PLAN
PROPERTY ADDRESS:
6830 174TH ST. SW
EDMONDS, WA 98026
11X17 DRAWING
1/4"=1' SCALE
EXISTING HOME 1776 SQ-FT'
PROPOSED ADDITION WILL ADD
AN ADDITIONAL TOTAL 469 SQ-FT'
SEE ENGINEERING
DRAWINGS PAGE S10.0
NOTE 3 FOR HAND &
GAURD RAIL DETAILS.
LEGEND
---- DEMOED WALLS
o NEW WALLS
o EXISTING WALLS
DECK
10'-4" X 10'- 7"
EXISTING 72"W X 48"T
VINYL SLIDER
WINDOW.
72"W X 48"T VINYL
SLIDER WINDOW
UF.26
72"W X 48"T VINYL
SLIDER WINDOW
UF.26
36"W X 48"T VINYL
SLIDER WINDOW
UF.26
in
Al
60"W X 36"T VINYL
SLIDER WINDOW —
UF.26
10'-8 1 /8" CIE !Jl
NEW VAULTED
CEILINGS ARE 2X12
RAFTERS 16" O.C. R-38
kTT INSULATION. 5/8"
ZYWALL
72" VINYL SLIDING
GLASS DORR. UF.3
KITCHEN & DINING
18'-0" X 23'-b"
SMOKE I
DETECTOR
0 PANTRY
GLO5ET
3'-1 " X 6'-7"
►n
GOAT GLOS
3'-3" X 2-7
42" PONY WALL
I
VAULTED CEILINGS ARE
2X12 RAFTERS 16" O.C.
R-38 BATT INSULATION.
5/8" DRYWALL
cv
LIVINCG
`y 12'-5" X 22-9"
I r—
SMOKE
DETECTOR
■
42" WIDE STAIREWLL,
CONTINUOUS HAND RAIL
@ 36" HEIGHT. 13 STAIR
TREDS WITH 6-7/8" RISE
PER TREAD.
7'-10 1/2"
40'-2 5/8"
30"W X 36"T SINGLE
HUNG OBSCURED
WINDOW. UF.26
15'-q 1/8" 2� �, �}� 6-2 5/8"
fz� o
--------------------
5HONER °
4'-11" X 4'-211 -
BATHROOM
4' 11"X
0.
SMOKE
DETECTOR
0
0
177751
SMOKEICC
DETECTOR
.-HAL-U -----0
�------------------------
['-4" X 3'-511
BEDROOM
10'-4" X T-1"
-1D�GK
5'" X
NEW EXTERIOR WALLS ARE 2X6 STUDS
16" O.C. 1/2" PLYWOOD FOR SHEER
WALL. R-21 INSULATION IN WALL, R-5
CONTINUOUS INSULATION EXTERIOR
SIDE. 1/2 DRYWALL INTERIOR SIDE.
CL05ET
4'-1" X l'-9"
SMOKE
DETECTOR
BEDROOM
10'-*7" X 15'-4"
3'
36"W X 48"T EXISITING VINYL
SINGLE HUNG EGRESS
WINDOW. @ 42" AFF.
TEMPERED GLASS WINDOW
PART OF DOOR ASSEMBLY
� NORTH
48" X 48" EXISITING
VINYL SLIDER EGRESS
WINDOW @ 42" AFF
EXISTING WALLS ARE
UNINSULATED. R-15
I INSULATION AND 1/2"
DRYWALL WILL BE
ADDED
NEW INTERIOR WALLS
ARE 2X4 STUDS 16" O.C.
1/2" DRYWAL.
SEE ENGINEERING
DRAWINGS PAGE S10.0
NOTE 3 FOR HAND &
GAURD RAIL DETAILS.
36"W X 48"T VINYL
SLIDER WINDOW
UF.26
36"W X 48"T EXISITING VINYL
SINGLE HUNG EGRESS
WINDOW. @ 42" AFF
RESUB
Aug 06 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
OWNER/CONTACT PERSON:
JOSHUA ANDERSON
206-718-7689
PROPERTY ADDRESS:
6830 174TH ST. SW
EDMONDS, WA 98026
11 X1 7 DRAWING
1/4"=1' SCALE
LEGEND
:___==-- DEMOED WALLS
NEW WALLS
o EXISTING WALLS
PROPSED MAIN FLOOPLAN
HEA--ING & VENTILA'-ION
KITCHEN ELECTRIC 80 CFM BATH
FLOOR HEATER EXHAUST FAN
380 CFM KITCHEN
HOOD EXHAUST FAN
co
in
DECK
10'-4" X 10'-7"
T'—
II
KITCHEN & DINING
1 b'-T X 23'-b"
SMOKE
DETECTOR
O PANTRY
3'-1 " X 2'-b"
MINI SPLIT
18K BTU IDU
Rp
cV
m
LIVING
12-5" X 22-T
i—
SMOKE
DETECTOR
O
Electric Fireplace
ry 3' 7'-10 1 /2"
Electric Fireplace
Heat output: 2,387 (low) - 4,700 (high) BTU's
0
BATHROOM ELECTRIC
FLOOR HEATER
80 CFM BATH BATHROOM ELECTRIC
EXHAUST FAN FLOOR HEATER
0
SMOKE
DETECTOR
CL05ET
4'-1" X T-T
BEDROOM
10'-7" X 15-4"
BEDROOM
CL05ET 10'-4" X T-7"
3'-1" X 6-7"
MINI SPLIT MINI SPLIT
9K BTU IDU 9K BTU IDU
COAT CLOSE
3'-Y X 2-7
21'-4"
1 '-4'
01
lnl
D CK
5'-1" X T-F t—
m
N
IN
i
-101, NORTH
RESUB
Aug 06 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
OWNER/CONTACT PERSON:
JOSHUA ANDERSON
206-718-7689
PROPERTY ADDRESS:
6830 174TH ST. SW
EDMONDS, WA 98026
11X17 DRAWING
1/4"=1' SCALE
EXISTING HOME 1776 SQ-FT'
PROPOSED ADDITION WILL ADD
AN ADDITIONAL TOTAL 469 SQ-FT'
EXISITNG BASEMENT HEATED BY
EXISITNG FORCED AIR FURNACE
LEGEND
o DEMO WALLS
EXISTING BASEMENT FLOOR PLAN
M.
11'-2 1 /2" 4'-0 1 /2" 11'-9" 2'-8" 8'-4"
cm
N
—000-- NORTH
RESUB
Aug 06 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
OWNER/CONTACT PERSON:
JOSHUA ANDERSON
206-718-7689
PROPERTY ADDRESS:
6830 174TH ST. SW
EDMONDS, WA 98026
11X17 DRAWING
1/4"=1' SCALE
EXISTING HOME 1776 SQ-FT'
PROPOSED ADDITION WILL ADD
AN ADDITIONAL TOTAL 469 SQ-FT'
EXISITNG BASEMENT HEATED BY
EXISITNG FORCED AIR FURNACE
N0TE:1 STEM WALL
EDSTPQ STEM WALL
NOTE: 2 WINDOW WELL
NEW WINDOW
CONCRETE
WINDOW WELL
I CONCRETE PAD
51 ING SLAS
!1TIM(:
NEW DRAIN PIPE
DOWN TO EXISITNG
FOOTING CRUSHED
ROCK
NEW CRUSHED ROCK EXISTING STEM WALL
EXISTING SLAB
EXISITING CRUSHED
ROCK FOR DRAINAGE
EXISTING FOOTING
LEGEND
--- DEMOED WALLS
o NEW WALLS
o EXISTING WALLS
o NEW STEM WALL
PROPOSED BASEMENT FLOOR PLAN
NEW WALLS THAT ARE
ATTACHED TO EXISTING
EXTERIOR STEM WALLS ARE
2X4 STUDS 16" O.C. WITH
R-15 INSULATION, 2" FOAM
INSULATION. 1/2" DRYWALL
a
►1
48"W X 30"T VINYL SLIDER
EGRESS WINDOW UF.26
@ 42" AFF. WINDOW NOT
BELOW GRADE
m
N
0
NOTEA STEM
WALL o
1
48" X 48" VINYL
SLIDER WINDOW
UF.26 @ 42" AFF.
NOTE: 2
WINDOW WELL
38'-1 "
36" X 24" EXISITING
VINYL SLIDER WINDOW
I n I 0' I I I i I n
10 -9 1 /2 ��TE 4� ATE 12 -5u 7i -10 1/2
48" X 36" VINYL SLIDER
SMOKE
EGRESS WINDOW UF.3 ETEcroa O LAUNDRY
Bath ROOM
@42" AFF Shower
SMOKE
BATHROOM OET R
9'-6" X 4'-11 "
BEDROOM I DETECTO
DETECTOR
11'-4" X 11'-10"
NEW INTERIOR WALLS
ARE 2X4 STUDS 16"
O.C. 1/2" DRYWALL
/ SMOKE
DETECTOR
0
FAMILY ROOM
SMOKE
24'-6° x 12'-�"
BEDROOM D
11'-4" X 14'-11" 0
NEW WALLS THAT ARE
ATTACHED TO EXISTING
EXTERIOR STEM WALLS ARE
2X4 STUDS 16" O.C. WITH
R-15 INSULATION, 2" FOAM
INSULATION. 1/2" DRYWALL
— NOTEA STEM WALL
UNFINISHED
AREA
NO HEATING
NO FLOORING 42" WIDE STAIREWLL,
CONTINUOUS HAND RAIL
@ 36" HEIGHT. 13 STAIR
TREDS WITH 6-7/8" RISE
R15 INSULATION, PER TREAD.
1/2" DRYWALL
Gil
I
NEW 6" STEM WALL. 2X6 STUDS 16" O.C.
R-21 INSULATION IN WALL, R-5
CONTINUOUS INSULATION EXTERIOR
SIDE. 1/2" PLYWOOR EXTERIOR SIDE, 1/2"
DRYWALL INTERIOR SIDE.
—10- NORTH
36" X 24" EXISITING
VINYL SLIDER WINDOW
Clouds indicate where a
thermal barrier is required.
Discuss with site inspector
on to achieve the code
requirements.
Room is not to be heated. Not to
be used a bedroom or other
conditioned uses.
RESUB
Aug 06 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
OWNER/CONTACT PERSON:
JOSHUA ANDERSON
206-718-7689
PROPERTY ADDRESS-
6830 174TH ST. SW
EDMONDS, WA 98026
11X17 DRAWING
1/4"=1' SCALE
EXISTING HOME 1776 SQ-FT'
PROPOSED ADDITION WILL ADD
AN ADDITIONAL TOTAL 469 SQ-FT'
EXISITNG BASEMENT HEATED BY
EXISITNG FORCED AIR FURNACE
LEGEND
--- DEMOED WALLS
o NEW WALLS
o EXISTING WALLS
o NEW STEM WALL
PROPOSED BASEMENT FLOOR PLAN
HEATING & VENTILATION
a
10'-9 1 /2" 4'
DETECT
EcraR
0
BEDROOM
11'-4" X 11'-10"
ELECTRIC WALL HEATER
5120 BTU
m
I
CV
ELECTRIC WALL HEATER
5120 BTU
BEDROOM DETEOCTEOR
11'-4" X 14'-11'. 0
I
0
UNFINISHED
AREA
NO HEATING
NO FLOORING
6-411 ATE 41 ATE / 1-411
351-11,
01 I_FYWAUST FA11
121-511
SMOKE/CO
DETECTOR
0
C7
BATHROOM ELECTRIC
FLOOR HEATER
3' 7'-10 1 /2"
o
LAUNDRY
ROOM
SMOKE
OET� R
m
ELECTRIC WALL HEATER
5120
ELECTRIC WALL HEATER
5120 BTU
SMOKE
DETECTOR
■
Cf)
FAMILY ROOM
24'-6" X 12-7
21 '-511
♦ NORTH
Table R406.2 ENERGY EQUALIZATION CRE
Credits -
STyp7te Description of Primary Heating Source select ONE
Type system
:E type
1 For combustion heating equipment meeting minimum federal efficiency standards for the 0 O
equipment listed in Table C403.3.2(5) or C403.3.2(6)
For an initial heating system using a heat pump that meets federal standards for the equipment
2 listed in Table C403.3.2(2) and supplemental heating provided by electric resistance or a 1.5 ❑
combustion furnace meeting minimum standards listed in Table C403.3.2(5)b found in the 2021
WSEC- COMMERCIAL ENERGY CODE
3 For heating system based on electric resistance only (either forced air or Zonal) 0.5 ❑
For heating system using a heat pump that meets federal standards for the equipment listed in
4` Table C403.3.2(2) or C403.3.2(9) or Air to water heat pump units that are configured to provide 3.0 ❑
both heating and cooling and are rated in accordance with AHRI 550/590
For heating system based on electric resistance with:
36K BTU ODU DUCTLESS 1. Inverter -driven ductless mini -split heat pump system installed in the largest zone in the
5 dwelling, 2.0 CK
MINI SPLIT UNIT
or
2. With 2kW or less total installed heating capacity per dwelling
RESUB
Aug 06 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
ELEVATIONS
DECK HEIGHTS MEASURED OFF GRADE
EAST SIDE ELEVATIONS
-� NORTH
MAXIMUM RIDGE
ELEVATION = 129.5'
ACUTAL RIDGE 1 24.5'
FI F\/ATInNI - 4 4 a 5'
AVERAGE GRADE
ELEVATION = 104.5'
RESUB
Aug 06 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
INTERIOR ELEVATIONS
l
00
M
-MAIN FLOOR KITCHEN & LIVING ROOM VAULTED CEILING 11'8"
-MAIN FLOOR BEDROOM CEILINGS 7'9"
-BASEMENT CEILINGS 7'3"
T
RESUB
Aug 06 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT