APPROVED BLD PLN RESUB2 BLD2024-0367+Architectural_Plan+6.3.2024_9.54.35_AM+4295791ABBREVIATIONS
AB
ANCHOR BOLT
ITT
HEIGHT
AGGR
AGGREGATE
HVAC
HEATING, VENTILATION
ALT
ALTERNATE
� AIR CONDITIONING
APPROX
APPROXIMATE
ID
INSIDE DIAMETER
ARCH
ARCHITECTURAL
INSUL
INSULATION
BD
BOARD
TNT
INTERIOR
BLDG
BUILDING
JNT
JOINT
BLK
BLOCK
JST
JOIST
BLKG
BLOCKING
LFA
LOAD FROM ABOVE
BM
BEAM
MAX
MAXIMUM
BOT
BOTTOM
MFR
MANUFACTURER
BTWN
BETWEEN
MIN
MINIMUM
CJ
CONTROL JOINT
MISC
MISCELLANEOUS
CLR
CLEAR
MO
MASONRY OPENING
CMU
CONCRETE MASONRY
MTL
METAL
UNIT
NO
NUMBER
COL
COLUMN
NTS
NOT TO SCALE
CONC
CONCRETE
OC
ON CENTER
CONN
CONNECTION
OD
OUTSIDE DIAMETER
CONSTR
CONSTRUCTION
OH
OVERHEAD
CONT
CONTINUOUS
OPG
OPENING
DEG
DEGREE
OPP
OPPOSITE
DET
DETAIL
PCT
PRE -CAST
DTL
DETAIL
PL
PROPERTY LINE
DIAG
DIAGONAL
PLYWD
PLYWOOD
DIA
DIAMETER
PLY
PLYWOOD
0
DIAMETER
RD
ROOF DRAIN
DN
DOWN
RE:
REFER TO ...
DWG
DRAWING
REINF
REINFORCED
(E)
EXISTING
READ
REQUIRED
EA
EACH
RM
ROOM
EJ
EXPANSION JOINT
RO
ROUGH OPENING
EIFS
EXTERIOR INSULATION
SCHED
SCHEDULE
� FINISH SYSTEM
SECT
SECTION
EL
ELEVATION
SF
SQUARE FOOT
ELEV
ELEVATION
SHT
SHEET
EQUIP
EQUIPMENT
SIM
SIMILAR
EW
EACH WAY
SPEC
SPECIFICATION
EXP
EXPANSION
SQ
SQUARE
EXT
EXTERIOR
SS
STAINLESS STEEL
FD
FLOOR DRAIN
STAGG
STAGGERED
FDN
FOUNDATION
STD
STANDARD
FF
FINISH FLOOR
STIFF
STIFFENER
FIN
FINISH
STL
STEEL
FLR
FLOOR
STRUC
STRUCTURAL
FND
FOUNDATION
TR
TREAD
FOB
FACE OF BRICK
TSB
TOP � BOTTOM
FOC
FACE OF CONCRETE
TAG
TONGUE � GROOVE
FS
FULL SIZE
THK
THICK
FT
FOOT OR FEET
T/
TOP OF
FTG
FOOTING
TYP
TYPICAL
FURR
FURRING
UNO
UNLESS NOTED
GA
GAUGE
OTHERWISE
GALV
GALVANIZED
VER
VERIFY
GR
GRADE
VERT
VERTICAL
GYP
GYPSUM
W/
WITH
GYP BD
GYPSUM BOARD
W/O
WITHOUT
GWB
GYPSUM WALL BOARD
�
CENTERLINE
�
PLATE
�Iones Reslc�ence Ac�dltlon
19303 88th Ave W Edmonds, WA 98026
DISCI AIMFR: THESE GENERAL NOTES ARE NOT NECESSARILY PROJECT
SPECIFIC, AND SOME NOTES MAY NOT APPLY TO EACH PROJECT.
ALL WORK IS TO COMPLY WITH TITS LATEST ADOPTED VERSION OF TITS
INTERNATIONAL RESIDENTIAL CODE (IRC) AND/OR ANY APPLICABLE COUNTY OR
LOCAL JURISDICTION. (IBC, IMC, WSEC, UPC)
THE CONTRACTOR IS RESPONSIBLE TO CHECK THE PLANS AND IS TO NOTIFY
TITS DESIGNER OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF
CONSTRUCTION. OWNER/CONTRACTOR SHALL VERIFY WITH LOCAL BLDG. DEFT
WHICH CLIMATE ZONE TITS PROJECT WILL BE BUILT IN.
WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
DO NOT SCALE THE DRAWINGS.
THIS PLAN IS DESIGNED TO MEET THE CURRENTLY ADOPTED WASHINGTON
STATE ENERGY CODE (202 I ).
INFILTRATION: THE SEALING METHODS BETWEEN DISSIMILAR MATERIALS SHALL
ALLOW FOR DIFFERENTIAL EXPANSION AND CONTRACTION. THE FOLLOWING
SHALL BE CAULKED, GASKETED, WEATHERSTRIPPED, OR OTHERWISE SEALED
WITH AN AIR BARRIER MATERIAL, SUITABLE FILM, OR SOLID MATERIAL.
- ALL JOINTS, SEAMS, AND PENETRATIONS
- SITE BUILT WINDOWS, DOORS, AND SKYLIGHTS
- OPENINGS BETWEEN WINDOW AND DOOR ASSEMBLIES AND THEIR
RESPECTIVE JAMBS AND FRAMING
- UTILITY PENETRATIONS
- DROPPED CEILINGS OR CHASES ADJACENT TO THE THERMAL ENVELOPE
- KNEE WALLS
- WALLS AND CEILINGS SEPARATING THE GARAGE FROM CONDITIONED SPACES
- BEHIND TUBS AND SHOWERS ON EXTERIOR WALLS
- COMMON WALLS BETWEEN DWELLING UNITS
- OTHER SOURCES OF INFILTRATION
INSUI ATION:
ALL EXPOSED INSULATION IS TO HAVE A FLAME SPREAD RATING NOT TO
EXCEED 25. ASMOKE-DEVELOPED INDEX NOT TO EXCEED 450, WHEN TESTED
IN ACCORDANCE WITH ASTM E 84, AND CRITICAL RADIANT FLUX NOT LESS
THAN 0. 12 WATTS PER SQUARE CENTIMETER.
INSULATE ALL ACCESS DOORS/HATCHES TO CRAWLSPACES AND ATTICS TO THE
EQUIVALENT RATING OF THE WALL, FLOOR, OR CEILING THROUGH WHICH THEY
PENETRATE.
ROOF (VAULTED CEILING)
R-38
ROOF (FLAT CEILING)
R-49
EXTERIOR WALLS
R-2 I
INSULATION
UNDERFLOOR INSULATION
R-30
WALLS BELOW GRADE (INTERIOR)
R-2 I
WALLS BELOW GRADE (EXTERIOR)
R- I 0
SLAB EDGES @HEATED AREAS
R- I 0
AIR DUCT (AT UNHEATED AREA)
R-8
MAXIMUM GLAZING AREA
NO LIMIT
GLAZING U-FACTOR (VERTICAL)
U=0.30
GLAZING U-FACTOR (OVERHEAD)
U=0.50
LAZING/
DOORS/ELEC
DOOR U-FACTOR
(DOORS W/MORE THAN 50% GLAZING
SHALL BE CONSIDERED A WINDOW)
U=0.20
FURNACE PERFORMANCE
80% EFF.
RECESSED LIGHTING FIXTURES
IC RATED
2
FUEL NORMALIZATION
I .O
(HEAT PUMP SYSTEM)
CREDITS
3.6
HIGH EFFICIENCY HVAC EQUIPMENT
2.0
(DUCTLESS SPLIT SYSTEM, NO ELEC)
CREDITS
TOTAL CREDITS:
3.0 CREDITS
GLAZING � EGRESS:
DOOR/WINDOW TAG:
5668 =WIDTH FEET/INCITES X OPENING HEIGHT FEET/INCf1ES
F_XAMPLE: 5668 IS 5'-6" WIDE x 6'-8" TALL
BASEMENTS AND EVERY SLEEPING ROOM TO HAVE MIN. WINDOW OPENING OF
5.7 SQ. FT. WITH A MIN. WIDTH OF 20" AND A SILL HEIGHT NOT MORE TITAN
44" ABOVE FIN. FLR.
WINDOWS SHALL HAVE TEMPERED GLAZING IF ANY SINGLE PANE OF GLASS
LARGER TITAN 9 SQUARE FEET, IF WITHIN 24" OF ANY DOOR (REGARDLESS OF
WALL PLANE), IF THE BOTTOM EDGE IS LESS TITAN 18" ABOVE THE FINISHED
FLOOR FLOOR OR WALKING, OR IS LOCATED WITHIN 36" FROM A WALKING
SURFACE.
ALL EXTERIOR WINDOWS ARE TO BE DOUBLE GLAZED AND ALL EXTERIOR
DOORS ARE TO BE SOLID CORE WEATHERSTRIPPING. PROVIDE I/2" DEAD BOLT
LOCKS ON ALL EXTERIOR DOORS AND LOCKING DEVICES ON ALL DOORS AND
WINDOWS WITHIN 10' (VERTICAL) OF GRADE. PROVIDE PEEPHOLE 54-66"
ABOVE FIN. FLR. ON EXTERIOR ENTRY DOORS.
GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS,
STEAM ROOMS, BATHTUBS, � SHOWERS, AND IN ANY PART OF A BUILDING
WALL ENCLOSING THESE COMPARTMENTS, WHERE BOTTOM EDGE OF GLAZING
IS LESS THAN 60" MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING
SURFACE, TO BE TEMPERED GLAZING.
ALARMS � ELECTRICAL:
SMOKE DETECTORS SHALL BE INSTALLED IN EA. SLEEPING ROOM, OUTSIDE
THE IMMEDIATE VICINITY OF EACH SLEEPING AREA, AND ON EACH STORY OF
THE DWELLING. ALL DETECTORS SHALL BE HARDWIRED INTO BUILDING POWER
SUPPLY W/BATTERY BACKUP AND BE INTERCONNECTED SUCH THAT THE
ACTUATION OF ONE ALARM WILL ACTUATE ALL THE ALARMS AND WILL BE
AUDIBLE IN ALL SLEEPING AREAS OVER BACKGROUND NOISE LEVELS WITH ALL
INTERVENING DOORS CLOSED.
ROOF SHEATHING IS I/2" PLY OR 7/I 6" OSB SPAN RATED 32/I 6 OR BETTER
NAILED W/ 8d's @ 6" O.C. AT EDGES � 12" O.C. AT FIELD. PLACE LONG
DIRECTION OF ALL SHEETS PERPENDICULAR TO TRUSS/RAFTER DIRECTION.
FRAMING NOTES:
TITS DOUBLE TOP PLATE IS TO BE CONTINUOUS ALONG ALL EXTERIOR WALLS
AND AT ALL WALL LINES CONTAINING SHEARWALLS. TYPICAL WALL TOP PLATE
SPLICES SHALL BE 27" LAP SPLICE W/ (2) ROWS OF 16d NAILS @ 3" O.C.
WHERE COMPOSITE JOISTS AND BEAMS ARE USED AS DRAG STRUTS TITS
MANUFACTURER SHALL PROVIDE THE FRAMING MEMBERS WITH THE CAPACITY
CALLED OUT ON THE PLANS.
AT ALL BEAM BEARING/JAMB LOCATIONS, AT MINIMUM PROVIDE BEARING
(TRIMMER) STUDS AND FULL HEIGHT (KING) STUDS PER THE JAMB STUD
SCHEDULE FOR EACH BUILDING IF PROVIDED. IF NO SCHEDULE, PROVIDE (I )
2x_ BEARING AND (I) 2x_ FULL HEIGHT STUD MINIMUM.
EXPOSED FRAMING SHALL BE PRESSURE TREATED (PT) VERTICAL �
HORIZONTAL FRAMING AT WATERPROOFED WALKWAYS AND PRIVATE DECKS.
ALL EXPOSED BEAM HANGERS SHALL BE POST HOT -DIPPED GALVANIZED AND
HAVE CONCEALED FLANGES.
PROVIDE WALL BLOCKING FOR ALL WALL MOUNTED EQUIPMENT (SUCH AS
TOWEL BARS, GRAB BARS, TOILET PAPER HOLDERS, DOOR STOPS, ETC.)
ALL CONNECTORS ARE TO BE SIMPSON STRONG TIE PRODUCTS ,UNLESS
NOTED OTHERWISE.
`:
� r r• -; �
ELECTRICAL RECEPTACLES IN BATHROOMS, KITCHENS, EXTERIOR LOCATIONS, TYPF I -NON-CIRCUI AR
AND GARAGES SHALL BE G.F.I. OR G.F.I.C. PER NATIONAL ELECTRICAL CODE PERIMETER DIMENSION BETWEEN 4" AND 6 I/4"
(N.E.C.) REQUIREMENTS. CROSS SECTION DIMENSION MAX. 2 I/4"
EDGES SHALL HAVE RADIUS MIN. O.OI"
WHOLE HOUSE VENTILATION TO BE MET PER IRC SECTION M 1505.4.3 � IRC
TABLE M 1505.4.3(I ): DWELLING AREA < I ,500; BEDROOMS 0- I ;RATE
REQUIREMENT 30 CFM.
PROVIDE POSITIVE VENTILATION AT EACH END OF RAFTER SPACE AT VAULTED
CEILING AREAS, AND INSULATION BAFFLES AT SAVE VENTS BETWEEN RAFTERS.
RAFTER VENTILATION IS ALSO REQUIRED AT BLOCKING LOCATIONS ABOVE THE
PLATE.
PROVIDE I SQ. FT. OF ROOF VENTILATION FOR EVERY 150 SQ. FT. OF LIVING
AREA.
PROVIDE I SQ. FT. OF CRAWL SPACE VENTILATION FOR EVERY 150 SQ. FT. OF
LIVING AREA.
JOISTS � TRUSSES:
ROOF AND FLOOR JOIST LOCATIONS ARE SCHEMATICALLY SHOWN ON THE
PLANS. IT IS NOT THE INTENT OF THE STRUCTURAL PLANS TO GRAPHICALLY
LOCATE ALL FRAMING MEMBERS. THE CONTRACTOR IS RESPONSIBLE FOR
SPACING FRAMING MEMBERS AS NOTED ON THE PLANS AND GENERATING
MEMBER LAYOUT FOR SHOP DRAWINGS AND QUANTITY TAKEOFFS.
THE TRUSS AND JOIST MANUFACTURER SHALL VERIFY BEARING COMPATIBILITY
(CRUSHING) WITH THE PLATE MATERIAL. TYPICALLY, COMPOSITE BEAMS SHALL
BE FULLY BEARING ON 2x_ WALLS. I.E. BREAK RIM OR BLOCKING TO ALLOW
FULL BEARING OVER PLATES.
SHEATHING:
FLOOR SHEATHING IS 3/4" TAG PLYWOOD SPAN RATED 48/24 OR BETTER
NAILED W/ I Od's @ 6" O.C. AT EDGES � 12" O.C. AT FIELD. PLACE LONG
DIRECTION OF ALL OSB SHEETS PERPENDICULAR TO JOIST DIRECTION.
TYPE 2 -PERIMETER GREATER THAN 6 I/4"
GRASPABLE FINGER RECESS AREA BOTH SIDES OF PROFILE
TO BEGIN W/IN 3/4" MEASURED VERTICALLY FROM THE TALLEST PART OF THE
PROFILE
TO ACHIEVE A DEPTH MIN. 5/ 16" W/IN 7/8" BELOW THE WIDEST PART OF THE
PROFILE
TO CONTINUE MIN. 3/8" TO A LEVEL MIN. 13/4" BELOW THE TALLEST PART OF
THE PROFILE
WIDTH OF THE HANDRAIL ABOVE THE RECESS BETWEEN I I /4" AND 2 3/4"
EDGES SHALL HAVE RADIUS MIN. O.OI"
SYMBOL LEGEND
X BUILDING DETAIL #
# SECTION SHEET #
REFERENCE
# DETAIL DETAIL #
# REFERENCE SHEET #
SKEET INDEX
SHEET
SHEET CONTENTS
CS
COVER SHEET
A0.0
SITE PLAN
A0. I
ENERGY CALCULATIONS
A I .0
AS -BUILT BUILDING ELEVATIONS
A I . I
AS -BUILT BUILDING ELEVATIONS
A I .2
PROPOSED BUILDING ELEVATIONS
A I .3
PROPOSED BUILDING ELEVATIONS
A2.0
AS -BUILT FIRST FLOOR PLAN
A2. I
AS -BUILT SECOND FLOOR PLAN
A2.2
PROPOSED FIRST FLOOR PLAN
A2.3
PROPOSED SECOND FLOOR PLAN
A2.4
OVERALL ROOF PLAN
A3.0
BUILDING SECTION, DETAILS � SCHEDULES
TOTAL NUMBER OF SHEETS
13
pr n iF�-r i non -rind
PROJECT INFORMATION
CLIENT: FRANK JONES � CITRISTINA LIDWIN
CONTACT:
MAILING 19308 88TIT AVE W
ADDRESS: EDMONDS, WA 98036
PARCEL#: 27041800308000
FLOOR AREAS:
I st FLOOR:
(E) 1907
2nd FLOOR:
(N) 1881
GARAGE:
(E) 440
TOTAL:
42 28
LOT SIZE: 28750 SO FT
ZONING: RS- I 0
DISCLAIMER:
CONTRACTOR IS TO VERIFY ALL SITE CONDITIONS AND ADAPT DESIGN PLANS AS
NECESSARY. ANY RESPONSIBILITY OF SIGMA DRAFTING AND DESIGN SERVICES, LLC FOR
ANY DAMAGES RELATING TO THE ACCURACY AND INTEGRITY OF THESE PLANS SHALL BE
LIMITED TO THE AMOUNT OF FEE CHARGED. IF ANY DISCREPANCY BETWEEN THESE PLANS
AND THE SITE CONDITIONS DIFFERS, IT IS RECOMMENDED THAT WORK BE STOPPED AND
THE DESIGNER BE CONSULTED.
THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION
OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR
TO CONSTRUCTION BY CALLING THE UNDERGROUND LOCATE LINE AT I -800-424-5555 A
MINIMUM OF 48 HRS. PRIOR TO ANY EXCAVATION.
CALL BEFORE YOU DIG
(800) 424-5555
"�Y
SIC�MA
DRAFTING &DESIGN
SERVICES, LLC
OLYMP IA, WA
360.464.5373
sigmadrafting.com
z
O
w
i
Drawn: MDC
Designed: MDC
scale: AS SHOWN
Date: 6/3/2024
Job Number:
24006
Sheet Number:
CS
1 �f 13
i�
W
Q
372'
19303 88TH AVE W EDMONDS, WA 98026
:-
SITE PLAN
PARCEL NO: 27041800308000
1" =15' ON 24x36 1" = 30' ON 11x17
AVERAGE FG = 386.8'
APPROX. FF = 389.3'
OF FIRST FLOOR
::
I
LEV = 387.8
SECOND STORY
STING FOOTPRINT
::
ADDITION OVER
SIC�I"IA
DRAFTING &DESIGN
SERVICES, LLC
0
w
OLYMPIA, WA
360.464.5373
sigmadrafting.com
SHED
�
�
�
�
S F
U
CV
�
SITE PLAN DISCLAIMER:
�
�
�
>
Q
�p
�
�
s
DO NOT SCALE.
�
s
Q
U
�
�
�
�
ITE NT R INF PR VIDED BY ITY F
S CO OU O O C O
�
�/
�
'OOD DECK
CITY OF EDMONDS
—
�
c�
�
�
�
�
�F
�
O
�
p
NOT INTENDED TO BE USED IN PLACE OF A
�
�
�
�
SURVEY.
O
-
�
W
�
THIS PLAN WAS CREATED FROM SATELLITE
�
�
:LEV = 386.
IMAGERY AND IS TO BE USED FOR
REPRESENTATION ONLY.
p
ALL CONTOURS AND BUILDINGS SHOWN ARE
SETBACK
REPRESENTATIVE ONLY AND NO
STRUCTURES OR PAVED AREAS SHALL BE
CONSTRUCTED BASED SOLELY ON THIS PLAN.
CONTRACTOR TO VERIFY ALL DIMENSIONS
ON SITE.
Drawn:
MDC
PROJECT INFORMATION
STRUCTURAL LOT COVERAGE:
EXISTING RESIDENCE FOOTPRINT: 1907
EXISTING ATTACHED GARAGE: 440
COVERED FRONT PORCH: 72
COVERED SIDE ENTRY: 24
TOTAL COVERAGE: 2443
386' I LOT AREA:
TOTAL STRUCTURAL COVER: 8.5�
28750
CALL BEFORE YOU DIG
(800) 424-5555
Designed: MDC
Scale: AS SHOWN
Date: 6/3/2024
Job Number:
24006
Sheet Number:
A0.0
2 �f 13
WSU Code Compliance Calculator, WSEC 2018
WSU Code Compliance Calculator, WSEC 2018
WSU Code Compliance Calculator, WSEC 2018
Project Information
Jones Residence Addition
3 Total Credits
Contact Information
Mike Currier - Sgima Drafting &Design
(360)464-5373
3515 Long Lake Dr SE, Olympia, WA 98503
UA Reduction = 1.87, Proposed UA is better than baseline by 1%
Whole House Mechanical Ventilation Airflow Rate: 120 CFM with Run Time Percent of 50 % ,Unbalanced, Not
esults assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ.
ANALYSIS SET UP
What code compliance pathway are you using?
Prescri five Path Com liance with O [ion 1 referred
Project Building Type?
Addition
Occupancy Type?
R3 Sin le Tamil homes and du lexes
Code Version?
WSEC 2018
Classification:
Small Dwelling Unit- 1433 sq. ft.
Baseline Description:
Code Baseline -Baseline and proposed window areas are equal.
About Your Selection:
Up to 15 sf exempt window and 24 sf exempt door allowable
RESULTS -Comparison of
Component Performance. R occupancies
Doors U =
Overhead Glazing U =
Vertical Glazing U =
FlatNaulted Ceilings U =
Wall (above grade) U =
Floors over Crawlspace U =
Slab on Grade F =
Below Grade Wall U =
Below Grade Slab F =
Baseline
II Arna IIA
0.300
0
0.0
0.500
24
12.0
0.300
223
66.9
0.027
1,409
38.0
0.056
76
4.3
0.029
430
12.5
0.540
0
0.0
0.042
0
0.0
0.570
0
0.0
Proposed Design
U nrna uA
0
0.0
0.500
24
12.0
0.300
223
66.9
0.027
1,409
38.0
0.054
76
4.1
0.025
430
10.8
0
0.0
0
0.0
0
0.0
Baseline UA Total 133.7 Proposed UA Total 131.8
Required Credits 3.0 Proposed Credits 3.0 from Tables 406.2 and 406.3
UA Percent Reduction 1.4%
UA Reduction 1.9
If the Proposed UA <_ the Target UA, and the Proposed Credits from Table 406 are >_ those required in Section R406, then the home meets the WSEC.
Table R406.2 Fuel Normalization Credits
Fuel Normalization
Total Credits
S stem No.
Full Descri lion
Select S stem T e
Credits 406.2
Ener Credits 406.3
(406.2 & 406.3)
For an initlal heating system using a heat pump that meets federal standards for the
equipment listed in Table C403.3.2(1 )C or C403.3.2(2) OR Air to water heat pump units that
are configured to provide both heating and cooling and are rated in accordance with AHRI
2
550/590. Heat pump with electric resistance or fossil -fuel supplemental heat requires
Heat Pump, air-to-air or air to water
1.0
2.0
3.0
compliance with WSEC 403.1.2 "Heat Pump Supplementary Heat". Packaged Terminal Heat
Pumps (PTAC-HP) requires an HSPF tested value (See SBC Interpretation dated December
2020).
Table R406.3 Energy Credits
O [ion No.
Cate o
Select O lions
Energy
Credits
Brief Descri lion of Selected O lions*
1
Efficient Building Envelope
0.0
2
Air Leakage Control and Efficient Ventilation
0.0
3
High Efficiency HVAC
2 0
Ductless Split System with no electric resistance in primary living
areas
4
High Efficiency HVAC Distribution System
NA
5.1
Efficient Water Heating
0.0
5.2-5.6
Efficient Water Heating
0.0
6
Renewable Electric Energy
kWh
0.0
7
Appliance Package
0.0
Energy Credits
2.0
*Refer to WSEC 2018 Table R406.3 for complete option descriptions and requirements
2018_W SU_C3_20220215_Master.xlsm
3/13/2024
Alterations Worksheet - 2018 Washington State Energy Code
Project Information Contact Information
Jones Residence Addition Mike Currier
19303 88th Ave W Edmonds, WA 98026
(360)464-5373
3515 Long Lake Dr SE, Olympia, WA 98503
The WSEC requirements for alterations are located in Chapter 5 of the code text.
Alterations (remodels) do not need to obtain energy credits from Table R406.3
Additions must meet the requirements for new construction. This includes nonconditioned space being
altered to become conditioned space.
Will the wall cavities be exposed? i,, Yes i No
If yes: Exposed wall cavities must be insulated -
2 X 4 wall studs require R-15 insulation
2 X 6 wall studs require R-21 insulation
Will the roof/ceiling framing cavities or attic be exposed? � Yes � No
If yes: Exposed roof/ceiling assemblies must be insulated -
Vaulted ceilings: Insulate to the full depth of the framing member
while allowing for the minimum 1" ventilated space
Flat ceilings:
Will the floor framing cavities be exposed?
Install R-49 insulation or what the attic space can
accommodate based on the roof pitch
i� Yes � No
If yes: Exposed floor cavities must be insulated to R-30
Are the windows and/or doors being replaced? i� Yes � No
(includes both window or door and frames)
If yes: New windows and doors must have an area weighted average U-factor of <_0.30
Will the heating or cooling system be replaced? i� Yes � No
If yes: New equipment must meet current requirements and
ducts need to be tested
Will the hot water system be altered? � Yes � No
If yes: New water heating equipment must meet current code requirements
THERMAL ENVELOPE DETAILS -Proposed Design
Conditioned Floor Area of Addition, Pro osed Desi n 1,433 sq. ft
Classification Small Dwelling Uni[
Notes
Exterior Doors
Plan
Com onent
Door
Width
Hei ht
ID
Descri lion
Ref.
U
Ot.
Feet
�"`"
Feet
I"`"
Area
UA
Exem t
0
0.0
0
0.0
0
0.0
0
0.0
0
0.0
0
0.0
0
0.0
0
0.0
0
0.0
0
0.0
0
0.0
Sum of Area and UA 0 0.0
Exterior Doors Area Weighted U
Overhead Glazing
Plan
ID
Component
Descri lion
Ref.
Glazing
U
Qt.
Width
Hei ht
Area
UA
Feet
�"`"
Feet
I"`"
2 I wood, a=0.05 ar on Code Baseline
10-6E
0.50
3
2
°
4
°
24
12
0
0
0
0
Sum of Area and UA 24 12
Overhead Glazing Area Weighted U 0.600
Vertical Glazing Schedule Rows to Show
g
Plan
Component
Glazing
Width
Hei ht
Feet
�"`"
Feet
I"`"
ID
Descri lion
Ref.
U
Ot.
Area
UA
Exem t
U=0.30 Code Baseline
Table 406.2
0.30
1
3
°
4
°
12.0
3.60
1
U=0.30 Code Baseline
Table 406.2
0.30
1
3
°
4
°
12.0
3.60
2
U=0.30 Code Baseline
Table 406.2
0.30
4
5
°
4
°
80.0
24.00
3
U=0.30 Code Baseline
Table 406.2
0.30
4
2
s
4
°
36.0
10.80
4
U=0.30 Code Baseline
Table 406.2
0.30
2
4
6
4
°
36.0
10.80
5
U=0.30 Code Baseline
Table 406.2
0.30
2
2
°
4
6
18.0
5.40
6
U=0.30 Code Baseline
Table 406.2
0.30
1
3
°
5
°
15.0
4.50
7
U=0.30 Code Baseline
Table 406.2
0.30
1
6
°
2
°
12.0
3.60
8
U=0.30 Code Baseline
Table 406.2
0.30
1
4
°
3
°
14.0
4.20
Sum of Area and UA (excluding exempt window) 223.0 66.9
Vertical Glazing Area Weighted U 0.300
Vertical Glazing and Doors Area Weighted U 0.300
FlaWaulted Ceilings
Plan
ID
Component
Descri lion
Ref.
Attic
U
Area
UA
R49 blown Attic STD baffled Code Baseline, O lion 1.1-1.4
10-7
0.027
1,409
38.0
Sum of Area and UA 1,409 38.0
Walls Above Grade
Plan
ID
Component
Descri lion
Ref.
Wall
U
Net Area
UA
R21 cavil +RO foam INT 2X6W La Code Baseline
10-5
0.054
76
4
Sum of Area and UA 76 4
Floor over crawl or exterior
Plan Component Floor UA
ID Descri lion Ref. U Area
1 2018 WSU C3 20220215 Masterxlsm
3/13/2024
R38 vented Joist 16oc O lions 1a-1 c, 1.3-1.5
10-3
0.025
430
11
Sum of Area and UA
430
11
Slab on Grade less than 2 fee[ below rode
Plan
ID
Component
Descri lion
Ref.
Slab
F
Slab Perim
FP
Sum of Perimeter and FP 0 0
Below Grade Walls and Slabs
Plan
ID
Component
Descri lion
Ref.
Wall
U
Wall
Area
Wall
UA
Slab
F
Slab Perim
Slab
UA
Sum of Area, Length and UA 0 0.0 0 0
Ventilation Requirements
Number of Bedrooms
2
Run -Time Percent in Each 4-Hour Segment
50
Is the system Balanced?
Unbalanced
Is the system Distributed?
Not Distributed
Ventilation Code Section
IRC, Chapter 15
Whole House Mechanical Ventilation Airflow Rate
120 CFM
HVAC Thermal Distribution System
Download RS-33 (2018) http://www.eneray.wsu.edu/Documents/Duct % 20Testinc % 20Standards % 20
Is this a hydronic heating system?
Nc,
Location of Ducts
Unducted
Location of Air Handler
Unconditioned S ace
Is Duct Testing
Required? No
Links to Download Forms, Checklists and Other Resources
Link
Compliance Certificate
Compliance Certifcate Instructions
Insulation Certificate for Residential New Construction
Insulation Certificate
Duct Testing Affadavits
Existing Construction
Affidavit, Existing
New Construction
Affidavit New
Prescriptive Checklist for 2018 WSEC
Prescriptive Checklist
Alterations (Remodel) Worksheet
Worksheet
Heatin S stem Sizin -Proposed Desi n Try Out BetterBuiltNW's HVAC Sizing Tool: https://betterbuiltnw.com/resources/hvac-sizing-tool
Nearest Weather Station
Edmonds
Indoor Design Temperature
70 F
Outdoor Design Temperature
24 F
Design Temperature Difference (�T)
46 F
Conditioned Floor Area of Addition, Proposed Design
1,433 ft2
Conditioned Volume
12,181 ft3
Leave blank to use default of 8.5 ft. ceiling height
HVAC System Type
Heat Pum
Location of HVAC Distribution System
Unducted
Sum of UA, including exempt door and window
135
Envelope Heat Load
6,229 Btu /Hour
Sum of UA X 4T
Air Leakage Heat Load
6,051 Btu /Hour
((VolumeX 0.6)X4T)X.018))
Building Design Heat Load
12,280 Btu /Hour
Air Leakage +Envelope Heat Loss
Building and Duct Heat Load
12,280 Btu /Hour
For ducts located in unconditioned space: Sum of Building Heat Loss X 1.1
For ducts located in conditioned space or ductless: Sum of Building Heat Loss X 1
Maximum Heat Equipment Output
16 350 Btu /Hour
Building and Ducl Heat Loss X 1.25 for heat pumps
Building and Duct Heat Loss X 1.40 for all other systems
2 2018_W SU_C3_20220215_Master.xlsm
3/13/2024
3
SIC�I"IA
DRAFTING &DESIGN
SERVICES, LLC
OLYMPIA, WA
360.464.5373
sigmadrafting.com
i
� ('�
V J
o_
v
�
N
('j�
I\ 1
""mVVV
V 1
�
�
V J
�
V
�
c.f�sQU
�
�
�
U
�
�
�
O
�,
�
O
-
�
W
�
O
Drawn: MDC
Designed: MDC
Scale: AS SHOWN
Date: 6/3/2024
Are more than 50°/t, of the light fixtures being changed? i.� Yes r No Job Number:
24006
If yes: 75% of all lamps must be high efficacy
(LED or CFL)
Sheet Number:
A0.1
3 �f 13
i�
FI_F\/ATION NOTE�i
ALL EFFORT TO INSURE THE ACCURACY OF THESE
DRAWINGS HAS BEEN TAKEN. HOWEVER,
CONTRACTOR IS TO VERIFY ALL NOTES, MATERIALS,
DIMENSIONS AND CONDITIONS IN THE FIELD.
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING
AND TEMPORARY BEARING WALL PLACEMENT AND
CONSTRUCTION.
ALL EXTERIOR JOINTS AND PENETRATIONS ARE TO
BE CAULKED.
PROVIDE SHEET METAL FLASHING AND
COUNTERFLASHING AT ALL ROOF PENETRATIONS,
CHIMNEYS, AND SKYLIGHTS.
EXTERIOR BUILDING WRAP TO BE CONTINUOUS
WHERE POSSIBLE. LAP ALL HORIZONTAL SEAMS 6"
MIN AND ALL VERTICAL SEAMS 6"- 12". TAPE ALL
BUILDING WRAP SEAMS AND TAPE BUILDING WRAP
TO FOUNDATION BELOW SILL PLATE.
PLUMBING AND VENTILATION PENETRATIONS ARE
NOT SHOWN AND ARE TO BE LOCATED BY THE
CONTRACTOR AND TO CONFORM TO IRC SECTION
P3 102.
PROVIDE CONTINUOUS GUTTERS AND
DOWNSPOUTS AT ALL EAVES TYPICAL. LOCATE PER
OWNER OR CIVIL.
HOLD ALL SIDING MATERIAL I"OFF OF ROOF AND
8" MIN OFF OF FINISHED GRADE.
ALL LIGHT BLOCKS ON FACADE ARE TO BE FURRED
OUR AN ADDITION I " FROM SIDING.
GUTTERS ARE TO LAP UNDER DRIP EDGE AT GABLE
ENDS.
ALL TRIM WORK IS TO BE INSTALLED PRIOR TO
SIDING MATERIALS. BUTT SIDING TO TRIM WORK
AND CAULK.
SIGMA DRAFTING � DESIGN TAKES NO
RESPONSIBILITY FOR WATER INTRUSION
PROTECTION. CONTRACTOR IS TO PROVIDE
ADEQUATE FLASHING, CAULKING, AND SEALING.
ROOF PEAK = 19'-3 5/8"
EXISTING FLOOR = 0'-0"
EXISTING TOP OF WALL = 7'-5 I/2"
EXISTING FLOOR = 0'-0"
AS -BUILT EAST ELEVATION
OWNER/CONTRACTOR
PROPOSED EAST ELEVATION
"�Y
SIC�MA
DRAFTING &DESIGN
SERVICES, LLC
OLYMP IA, WA
360.464.5373
sigmadrafting.com
z
O
w
�
�
�
�
-�-�
�
v
�
�
_►
c6
�
�
�
11J
�
�
�
��s
�
�
�
Q
U
-
�
��-�
�
�/
�
�
�
�
�
�
�
�
�
�
�
O
m
6�
0
�
�
�
�
W
�
I
�
Drawn: MDC
Designed: MDC
scale: AS SHOWN
Date: 6/3/2024
Job Number:
24006
Sheet Number:
A1.0
4 �f 13
FI_F\/ATION NOTE�i
ALL EFFORT TO INSURE THE ACCURACY OF THESE
DRAWINGS HAS BEEN TAKEN. HOWEVER,
CONTRACTOR IS TO VERIFY ALL NOTES, MATERIALS,
DIMENSIONS AND CONDITIONS IN THE FIELD.
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING
AND TEMPORARY BEARING WALL PLACEMENT AND
CONSTRUCTION.
ALL EXTERIOR JOINTS AND PENETRATIONS ARE TO
BE CAULKED.
PROVIDE SHEET METAL FLASHING AND
COUNTERFLASHING AT ALL ROOF PENETRATIONS,
CHIMNEYS, AND SKYLIGHTS.
EXTERIOR BUILDING WRAP TO BE CONTINUOUS
WHERE POSSIBLE. LAP ALL HORIZONTAL SEAMS 6"
MIN AND ALL VERTICAL SEAMS 6"- 12". TAPE ALL
BUILDING WRAP SEAMS AND TAPE BUILDING WRAP
TO FOUNDATION BELOW SILL PLATE.
PLUMBING AND VENTILATION PENETRATIONS ARE
NOT SHOWN AND ARE TO BE LOCATED BY THE
CONTRACTOR AND TO CONFORM TO IRC SECTION
P3 102.
PROVIDE CONTINUOUS GUTTERS AND
DOWNSPOUTS AT ALL EAVES TYPICAL. LOCATE PER
OWNER OR CIVIL.
HOLD ALL SIDING MATERIAL I"OFF OF ROOF AND
8" MIN OFF OF FINISHED GRADE.
ALL LIGHT BLOCKS ON FACADE ARE TO BE FURRED
OUR AN ADDITION I " FROM SIDING.
GUTTERS ARE TO LAP UNDER DRIP EDGE AT GABLE
ENDS.
ALL TRIM WORK IS TO BE INSTALLED PRIOR TO
SIDING MATERIALS. BUTT SIDING TO TRIM WORK
AND CAULK.
SIGMA DRAFTING � DESIGN TAKES NO
RESPONSIBILITY FOR WATER INTRUSION
PROTECTION. CONTRACTOR IS TO PROVIDE
ADEQUATE FLASHING, CAULKING, AND SEALING.
AS-P U I LT WEST ELEVATION
AICIA/ /"l"1\ITIA II Illl I(-' rJll"l /"�C \ /CI.IT
PROPOSED WEST ELEVATION
`"`Y"_
ROOF PEAK = 19'-3 5/8" DRAFTING &DESIGN
SERVICES, LLC
OLYMP IA, WA
360.464.5373
sigmadrafting.com
EXISTING ASPHALT ROOFING �
Q
EXISTING FLOOR = 0'-0"
EXISTING TOP OF WALL = 7'-5 I/2"
z
O
EXISTING FLOOR = 0'-0" >
w
u
\^V1' \Ij
V
O
Drawn: MDC
Designed: MDC
scale: AS SHOWN
Date: 6/3/2024
Job Number:
24006
Sheet Number:
A1.1
5 of 13
FI_F\/ATION NOTE�i
ALL EFFORT TO INSURE THE ACCURACY OF THESE
DRAWINGS HAS BEEN TAKEN. HOWEVER,
CONTRACTOR IS TO VERIFY ALL NOTES, MATERIALS,
DIMENSIONS AND CONDITIONS IN THE FIELD.
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING
AND TEMPORARY BEARING WALL PLACEMENT AND
CONSTRUCTION.
ALL EXTERIOR JOINTS AND PENETRATIONS ARE TO
BE CAULKED.
PROVIDE SHEET METAL FLASHING AND
COUNTERFLASHING AT ALL ROOF PENETRATIONS,
CHIMNEYS, AND SKYLIGHTS.
EXTERIOR BUILDING WRAP TO BE CONTINUOUS
WHERE POSSIBLE. LAP ALL HORIZONTAL SEAMS 6"
MIN AND ALL VERTICAL SEAMS 6"- 12". TAPE ALL
BUILDING WRAP SEAMS AND TAPE BUILDING WRAP
TO FOUNDATION BELOW SILL PLATE.
PLUMBING AND VENTILATION PENETRATIONS ARE
NOT SHOWN AND ARE TO BE LOCATED BY THE
CONTRACTOR AND TO CONFORM TO IRC SECTION
P3 102.
PROVIDE CONTINUOUS GUTTERS AND
DOWNSPOUTS AT ALL EAVES TYPICAL. LOCATE PER
OWNER OR CIVIL.
HOLD ALL SIDING MATERIAL I"OFF OF ROOF AND
8" MIN OFF OF FINISHED GRADE.
ALL LIGHT BLOCKS ON FACADE ARE TO BE FURRED
OUR AN ADDITION I " FROM SIDING.
GUTTERS ARE TO LAP UNDER DRIP EDGE AT GABLE
ENDS.
ALL TRIM WORK IS TO BE INSTALLED PRIOR TO
SIDING MATERIALS. BUTT SIDING TO TRIM WORK
AND CAULK.
SIGMA DRAFTING � DESIGN TAKES NO
RESPONSIBILITY FOR WATER INTRUSION
PROTECTION. CONTRACTOR IS TO PROVIDE
ADEQUATE FLASHING, CAULKING, AND SEALING.
EXISTING LAP SIDING
W/ 7" REVEAL
VERIFY IN FIELD
EXISTING OPENING TRIM
EXISTING CORNER TRIM
5/4x8 FASCIA BD
W/ K-LINE GUTTER
CORNER TRIM MATCH EXISTING
PER OWNER/CONTRACTOR
OPENING TRIM MATCH EXISTING
PER OWNER/CONTRACTOR
NEW LAP SIDING TO MATCH
EXISTING AT ALL LOCATIONS
EXISTING LAP SIDING
AS -BUILT NOf�Th ELEVATION
Pf�OPOSED NORTH ELEVATION
"�Y
SIC�MA
DRAFTING &DESIGN
SERVICES, LLC
OLYMP IA, WA
360.464.5373
sigmadrafting.com
z
O
w
�
�
�
�
-I--�
�
�6
�
N
�
�
v
_�
W
�
>
�
�
����s
�
�
�
Q
�
U
�
�
�
-'*�
�
�
�
�
�
�
�
�
�
Q�
m
0
�
�
O
�
�
�
�
W
�
L
Q—
Drawn: MDC
Designed: MDC
scale: AS SHOWN
Date: 6/3/2024
Job Number:
24006
Sheet Number:
A1.2
6 �f 13
FI_F\/ATION NOTE�i
ALL EFFORT TO INSURE THE ACCURACY OF THESE
DRAWINGS HAS BEEN TAKEN. HOWEVER,
CONTRACTOR IS TO VERIFY ALL NOTES, MATERIALS,
DIMENSIONS AND CONDITIONS IN THE FIELD.
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING
AND TEMPORARY BEARING WALL PLACEMENT AND
CONSTRUCTION.
ALL EXTERIOR JOINTS AND PENETRATIONS ARE TO
BE CAULKED.
PROVIDE SHEET METAL FLASHING AND
COUNTERFLASHING AT ALL ROOF PENETRATIONS,
CHIMNEYS, AND SKYLIGHTS.
EXTERIOR BUILDING WRAP TO BE CONTINUOUS
WHERE POSSIBLE. LAP ALL HORIZONTAL SEAMS 6"
MIN AND ALL VERTICAL SEAMS 6"- 12". TAPE ALL
BUILDING WRAP SEAMS AND TAPE BUILDING WRAP
TO FOUNDATION BELOW SILL PLATE.
PLUMBING AND VENTILATION PENETRATIONS ARE
NOT SHOWN AND ARE TO BE LOCATED BY THE
CONTRACTOR AND TO CONFORM TO IRC SECTION
P3 102.
PROVIDE CONTINUOUS GUTTERS AND
DOWNSPOUTS AT ALL EAVES TYPICAL. LOCATE PER
OWNER OR CIVIL.
HOLD ALL SIDING MATERIAL I"OFF OF ROOF AND
8" MIN OFF OF FINISHED GRADE.
ALL LIGHT BLOCKS ON FACADE ARE TO BE FURRED
OUR AN ADDITION I " FROM SIDING.
GUTTERS ARE TO LAP UNDER DRIP EDGE AT GABLE
ENDS.
ALL TRIM WORK IS TO BE INSTALLED PRIOR TO
SIDING MATERIALS. BUTT SIDING TO TRIM WORK
AND CAULK.
SIGMA DRAFTING � DESIGN TAKES NO
RESPONSIBILITY FOR WATER INTRUSION
PROTECTION. CONTRACTOR IS TO PROVIDE
ADEQUATE FLASHING, CAULKING, AND SEALING.
EXISTING LAP SIDI
W/ 7" REVS
VERIFY IN FIE
5/4x8 FASCIA BD
W/ K-LINE GUTTER
TOP OF WALL = 8'- I I /8"
CORNER TRIM MATCH EXISTING
PER OWNER/CONTRACTOR
OPENING TRIM MATCH EXISTING
PER OWNER/CONTRACTO�
NEW LAP SIDING TO MATCr
EXISTING AT ALL LOCATION
EXISTING FLOOR = 0'-0"—
EXISTING TOP OF WALL = 7'-5 I /2"—
EXISTING LAP SIDING
EXISTING FLOOR = 0'-0"—
AS-BUILT SOUTH ELEVATION
AICIA/ ACOLJAIT �/lr1CIA I/` �AATl�LJ
PROPOSED SOUTH ELEVATION
\/FPIFV FVIC,TI�I(` P!l(lF
"�Y
SIC�MA
DRAFTING &DESIGN
SERVICES, LLC
z
O
w
OLYMP IA, WA
360.464.5373
sigmadrafting.com
N
� O
Q �
s Q
� �
c� `�
O �
c� O
6� �
— �
W
Drawn: MDC
Designed: MDC
scale: AS SHOWN
Date: 6/3/2024
Job Number:
24006
Sheet Number:
A1.3
7 �f 13
cr
C
�r
AS -BUILT FI f�ST �LOOf� PLAN
2 I '-4 I /2"
0
N
"�Y
SIC�MA
DRAFTING &DESIGN
SERVICES, LLC
n
r
Z
O
w
OLYMP IA, WA
360.464.5373
sigmadrafting.com
�
�
L
O
�
v
�
�
�6
�
_
�
�
�
�
�
Q
�
�
�
`�
L
_
�s�U
I..L_.
�
�
�
-`�
�
�
m
�
�
�
�
�
�
�
�
0
0
�
�
O
�
�
�
�
-
�
W
L
O
AS-Bl J I I T NOTES
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING
AND TEMPORARY BEARING WALL PLACEMENT AND
CONSTRUCTION.
CONTRACTOR IS TO VERIFY DIMENSIONS OF ALL
REMOVED WALLS AND SLABS IN THE FIELD.
ALL EXISTING INTERIOR WALLS ARE OBSERVED TO
BE 2x4 CONSTRUCTION.
ALL EXISTING EXTERIOR WALLS ARE OBSERVED TO
BE 2x4 CONSTRUCTION.
Drawn: MDC
Designed: MDC
scale: AS SHOWN
Date: 6/3/2024
Job Number:
24006
Sheet Number:
A2.0
8 �f 13
AS -BUILT SECOND FLOOD PLAN
AS-Bl J I I T NOTES
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING
AND TEMPORARY BEARING WALL PLACEMENT AND
CONSTRUCTION.
CONTRACTOR IS TO VERIFY DIMENSIONS OF ALL
REMOVED WALLS AND SLABS IN THE FIELD.
ALL EXISTING INTERIOR WALLS ARE OBSERVED TO
BE 2x4 CONSTRUCTION.
ALL EXISTING EXTERIOR WALLS ARE OBSERVED TO
BE 2x4 CONSTRUCTION.
"�Y
SIC�MA
DRAFTING &DESIGN
SERVICES, LLC
OLYMP IA, WA
360.464.5373
sigmadrafting.com
z
O
w
�
_�
�_
L
O
�
�
�
�
�6
0
�
�
(�
l(i
�
�
�
Q
S
U
O
�
��-�
v
�
�,
�
�
�
�o�
0
-�'
�
O
m
�
o
�
�
�
W
�
I
lli
�
�
Q
,
Drawn: MDC
Designed: MDC
scale: AS SHOWN
Date: 6/3/2024
Job Number:
24006
Sheet Number:
A2.1
9 �f 13
i�
A
A3.0
FURR TO 2x6 /�
R-2 I INSULATION
31034 11034
r — _ _ _ _ — � � _ = I —
II II �
II II �
I I i i TUB I
I Y
�— I t
Imo— I
II � �
o I I � �-
BEDROOM I L— — — �- �flZti- ,i a
I I'-2" X 15'-3" I I t
I I
II ° —�
II I _ i
II I� � o �
II II o m
II SDIL-- N ��J
O 2668
I 5D GO �
I 3068 � 3068 �o
II II N
m
��
i 1268
I S.G.
DECK
9'-8" X 7'-2"
.� 4'-8 I /2"
3068 11268
/ S.G.
18070
II I I II
II I I II
lo„ II I I II
I I CEILING TO HAVE 5/8" I I I
M NE-X GWB, FIRE -TAPED
II I I II
II �------------ -----� II
II II
II II
GARAGE
II 209 X197 II
I I ISH CONC I I
I (N) LEVEL II OR III EV
I e CHARGING RECEPTACLE
VERIFY INSULATED
I STEEL SELF CLOSING
I FU RR TO 2x6 W/
R-2 I INSULATION
NEW ENTRY
13'-9" X I O'- I O"
OPEN TO ABOVE
I/2"
I`-------J�-- 3056 --- �------��
�-------------- ---- ---- I 11
T I II
I II
� -__�
I II
I � II
I -6 -�
A I z II
A3.0 I � II
—� —�
I Q II
I II
I =__�
I GARAGE WARM WALLS TO BE 2x6 DOOR I
I I WALL W/ R-1 5 INSULATION W/ I I
I I 5/8" TYPE-X GWB FIRE -TAPE MIN I I
II II
ATRIUM WINDOWS I I HD 3068 I I
L---------- --�-�
— --
I----------1�
o I wH II
II
II �__ ��
I I � � I I I'-7" X 5'-2" I
2'- I " I I 5' 7gAT� 7 � 2668 � � I
� —��
2668------� I
� �
I I
N POWDER � I I
5'-II"X4'-I I" �-O�-Z I I
--- --- 9'-O"X6'-2"
�� I IT
L-- L---------��--J I
,r----r-- �rI��T
II I I I
II UP
II ��1
II �II
FREE STANDING I � — —
FIREPLACE
BREAKFAST I
12'- I " X 9'-6" I I
I
u
Pf�OPOSED FIRST FLOOf� PLAN
--�
l l
I
I
N PANTRY
3'- I O" X 4'-G" I
!L---��
_ - NEW WALL
_ _ _ - EXISTING WALL
SD - SMOKE ALARM PER IRC R3 14
CO - CARBON MONOXIDE ALARM PER IRC R3 15
Hp - HEAT DETECTOR ALARM PER IRC R3 14
- EXHAUST FAN PER IRC TABLE M 1505.4.4
KITCHEN: 100 CFM INTERMITTENT OR 25
CFM CONTINUOUS
BATH: 50 CFM INTERMITTENT OR 20 CFM
CONTINUOUS
W.N.F.: 125 CFM WHOLE HOUSE FAN ON 50%
RUN TIMER
ALL EFFORT TO INSURE THE ACCURACY OF THESE
DRAWINGS HAS BEEN TAKEN. HOWEVER, CONTRACTOR IS
TO VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD.
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING AND
TEMPORARY BEARING WALL PLACEMENT AND
CONSTRUCTION .
ALL NEW WALLS ARE TO BE 2x6 STUDS @ 16" O.C. AT
EXTERIOR AND 2x4 STUDS @ 16" O.C. AT INTERIOR.
UNLESS NOTED OTHERWISE BY STRUCTURAL.
ALL WINDOW AND DOOR HEADERS ARE TO BE MIN #2 DF
4x8 AT 6'-8" FROM F.F., UNLESS NOTED OTHER WISE BY
STRUCTURAL.
ALL WINDOWS WITHIN 18" OF FLOOR AND 12" OF ANY
DOOR ARE TO HAVE TEMPERED GLASS.
ALL SHOWER AND BATHTUB ENCLOSURES ARE TO BE
GLAZED W/ SAFETY GLASS.
PROVIDE COMBUSTION AIR VENTS W/ SCREENS AND
DAMPER FOR FIREPLACES, WOOD STOVES, AND ANY
APPLIANCE W/ ANY OPEN FLAME.
ALL COMBUSTION APPLIANCES WILL BE VENTED DIRECTLY
TO THE EXTERIOR. FURNACE FIREBOX AND TANKLESS WATER
HEATERS SHALL HAVE OUTSIDE COMBUSTION AND ARE
SUPPLY PURSUANT TO REGIONAL AND LOCAL CODES.
EXHAUST ALL VENTS AND FANS DIRECTLY TO OUTSIDE VIA
METAL DUCTS.
UNDER -FLOOR SPACES SHALL HAVE VENTILATION EQUAL TO
I SF PER 150 SF OF FLOOR SPACE. VENTS SHALL BE CAST
INTO THE STEMWALLS AND BE COVERED W/ GALVANIZED
WIRE SCREEN. VENTS SHALL BE LOCATED TO PROVIDE
CROSS -VENTILATION.
ELECTRICAL RECEPTACLES IN BATHROOMS, KITCHENS, AND
GARAGES SHALL BE G.F.I. OR G.F.C.I. PER NATIONAL
ELECTRICAL CODE REQUIREMENTS.
ALL EXTERIOR WALL INTERIOR DRYWALL JOINTS ARE TO BE
MUD AND TAPED AND TO HAVE A CLASS I OR I I VAPOR
BARRIER. ALL DRYWALL EDGES AT WALL BOTTOM AND WALL
TOP ARE TO BE CAULKED BEFORE FINISHING.
ALL ELECTRICAL BOXES ARE TO BE AIR TIGHT 9R TO HAVE
CAULKED/FOAMED WIRE PENETRATIONS AND GASKETED
COVER PLATES.
ALL LIGHT FIXTURES ARE TO BE RATED ICAT.
ALL DRYWALL PENETRATIONS ARE TO BE CAULKED OR
SPRAY FOAMED CLOSED.
ALL FRAMING MATERIAL THAT IS IN CONTACT WITH
CONCRETE IS TO BE PRESSURE TREATED.
FOR OPENINGS NOT DIMENSIONED, ASSUME 4" RETURN TO
JAMB -SIDE OR CL OF DOOR IS AT CL OF SPACE.
AS-Bl J I I T NOTES
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING
AND TEMPORARY BEARING WALL PLACEMENT AND
CONSTRUCTION.
CONTRACTOR IS TO VERIFY DIMENSIONS OF ALL
REMOVED WALLS AND SLABS IN THE FIELD.
ALL EXISTING INTERIOR WALLS ARE OBSERVED TO
BE 2x4 CONSTRUCTION.
ALL EXISTING EXTERIOR WALLS ARE OBSERVED TO
BE 2x4 CONSTRUCTION.
"�Y
SIC�MA
DRAFTING &DESIGN
SERVICES, LLC
OLYMP IA, WA
360.464.5373
sigmadrafting.com
z
O
w
�
�_
_�
o����
O
�
�
(�
l(i
S
U 1
�
�
�
�
S___
11-i
�
�
�
�
O
�
�
O
�
O
m
6�
O
�
�
O
�
u�
�
�
�
O
L
Q
�--
Drawn: MDC
Designed: MDC
scale: AS SHOWN
Date: 6/3/2024
Job Number:
24006
Sheet Number:
A2.2
1 � of
1��
-6"
14'-5"
5040
A
A3.0
9'-5"
I
L.C)
� m
� � 8'- I I " X 4'-6"
N O N �
m m
N r
�(2) STUDS
0
BEDROOM
13'- I I " X 17'-7"
� �(2) STUDS
N
5040
7'-6"
5'-7"
5D
N 5'-6" X__8'- I I 'I'
m ��
II II
II II
u u
II II
�L- JI
266
I
4'-5" �
c� �
N
3040
6'-I I" 4'-10"
27'-5 I /2"
A
A3.0
2 I '-4 I /2"
10'-8 I /4"
2340
5040 2340
(2) STUDS
�(2) STUDS
�
3:12
a
3:12
�
►�
VAULT
VAULT'
�
I�
N
BEDROOM
� �
°�
20'-5" X 13'- I I"
� J
�
Iw
v
N
O
9'-5 I /2"
6'-4" 3'-9"
� 10'-4 I /2"
4'-8 I /2"
2046 3050 2046
5D 4�_ I ��
N
LINEN
N
�
C9
�
C9
�
i— a i— u �
�
N
CHAMFER AS-
�
FUTURE
� C BL
S
NEEDED
3'-4"
STACKED
W/D -
®N SHOWER
- — �
OPEN BELOW
I
— — �
13'-9" X I O'-7°
�
4640
-�
I
= _ �A�I;� HT�
�r
—�II W/GI�SS
--�
— — �
_
2'-5"
6'-5"
6'-6" =
III II
m—
--I��=====�J
--
— — � —
-------
_�
I m
--
�
�
I BATH �°
-
- —
�
CLOSET
�
18'-3" X 13'-8° �
m
15'-3"
X 7'- I O"
o
r=—��
D I II N
-
6�
I II �
�
�
II d-
2668
'
N
2868
N 40" TALL
II Ni
II II
�L = J� N 2'-2" �
\ 3'-9 I /2" I I '- 10" 4'-0 I /2" 9'- I " �
m 31020 31020 2468
--- 2868=--------- ---
r � � 34'-7 I /2" — —
N 82 � � � � I
0 o II II GO 5D II
_ � II LL �_ �� � �� �_ � DN O
m � �J�4068 =____-_____- 3068
� �
I
o N BEDROOM 5D N
18'- I I " X I O'-O"
N �_ I
— O
II SITTING m
- I I °
15'-4" X9'- I I " m
II
N __________ II II
N------- — II II
0
4'-7" � II
r — — — _ _CEILING RIDGE _ _ _ _ � I
Ir ___ 5D =;1
�, I
o I
I
I
II II
II II
II II
II
Ik====______====�1
II II
II II
II II
II II
OPEN BELOW
I I 14'-O" X 7'-7" I I
II II
II II
L=====-----=====J
Pf�OPOSED SECOND FLOOf� PLAN
N
d"
N
m
N N
— m
N_
c�
FLOOR PLAN NOTES
®- NEW WALL
_ __ - EXISTING WALL
SD - SMOKE ALARM PER IRC R3 14
CO -CARBON MONOXIDE ALARM PER IRC R3 15
Hp - HEAT DETECTOR ALARM PER IRC R3 14
- EXHAUST FAN PER IRC TABLE M 1505.4.4
KITCHEN: 100 CFM INTERMITTENT OR 25
CFM CONTINUOUS
BATH: 50 CFM INTERMITTENT OR 20 CFM
CONTINUOUS
W.H.F.: 125 CFM WHOLE HOUSE FAN ON 50%
RUN TIMER
ALL EFFORT TO INSURE THE ACCURACY OF THESE
DRAWINGS HAS BEEN TAKEN. HOWEVER, CONTRACTOR IS
TO VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD.
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING AND
TEMPORARY BEARING WALL PLACEMENT AND
CONSTRUCTION .
WALL HEIGHT = 8'- I I /8"
CFII ING TYPE = VAUI TF WH R NOT D, FLAT TYPIC:AI_
ALL NEW WALLS ARE TO BE 2x6 STUDS @ 16" O.C. AT
EXTERIOR AND 2x4 STUDS @ 16" O.C. AT INTERIOR.
UNLESS NOTED OTHERWISE BY STRUCTURAL.
ALL WINDOW AND DOOR HEADERS ARE TO BE MIN #2 DF
4x8 AT 6'-8" FROM F.F., UNLESS NOTED OTHER WISE BY
STRUCTURAL.
ALI EXTERIOR HEADERS MUST BE 4x SIZES UNI_FSS
SPFCIFIFf� BY STRIIC:TURAI .
ALL WINDOWS WITHIN 18" OF FLOOR AND 12" OF ANY
DOOR ARE TO HAVE TEMPERED GLASS.
ALL SHOWER AND BATHTUB ENCLOSURES ARE TO BE
GLAZED W/ SAFETY GLASS.
PROVIDE COMBUSTION AIR VENTS W/ SCREENS AND
DAMPER FOR FIREPLACES, WOOD STOVES, AND ANY
APPLIANCE W/ ANY OPEN FLAME.
ALL COMBUSTION APPLIANCES WILL BE VENTED DIRECTLY
TO THE EXTERIOR. FURNACE FIREBOX AND TANKLESS WATER
HEATERS SHALL HAVE OUTSIDE COMBUSTION AND ARE
SUPPLY PURSUANT TO REGIONAL AND LOCAL CODES.
EXHAUST ALL VENTS AND FANS DIRECTLY TO OUTSIDE VIA
METAL DUCTS.
UNDER -FLOOR SPACES SHALL HAVE VENTILATION EQUAL TO
I SF PER 150 SF OF FLOOR SPACE. VENTS SHALL BE CAST
INTO THE STEMWALLS AND BE COVERED W/ GALVANIZED
WIRE SCREEN. VENTS SHALL BE LOCATED TO PROVIDE
CROSS -VENTILATION.
ELECTRICAL RECEPTACLES IN BATHROOMS, KITCHENS, AND
GARAGES SHALL BE G.F.I. OR G.F.C.I. PER NATIONAL
ELECTRICAL CODE REQUIREMENTS.
ALL EXTERIOR WALL INTERIOR DRYWALL JOINTS ARE TO BE
MUD AND TAPED AND TO HAVE A CLASS I OR I I VAPOR
BARRIER. ALL DRYWALL EDGES AT WALL BOTTOM AND WALL
TOP ARE TO BE CAULKED BEFORE FINISHING.
ALL ELECTRICAL BOXES ARE TO BE AIR TIGHT 9R TO HAVE
CAULKED/FOAMED WIRE PENETRATIONS AND GASKETED
COVER PLATES.
ALL LIGHT FIXTURES ARE TO BE RATED ICAT.
ALL DRYWALL PENETRATIONS ARE TO BE CAULKED OR
SPRAY FOAMED CLOSED.
ALL FRAMING MATERIAL THAT IS IN CONTACT WITH
CONCRETE IS TO BE PRESSURE TREATED.
FOR OPENINGS NOT DIMENSIONED, ASSUME 4" RETURN TO
JAMB -SIDE OR CL OF DOOR IS AT CL OF SPACE.
AS-Bl J I I T NOTES
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING
AND TEMPORARY BEARING WALL PLACEMENT AND
CONSTRUCTION.
CONTRACTOR IS TO VERIFY DIMENSIONS OF ALL
REMOVED WALLS AND SLABS IN THE FIELD.
ALL EXISTING INTERIOR WALLS ARE OBSERVED TO
BE 2x4 CONSTRUCTION.
ALL EXISTING EXTERIOR WALLS ARE OBSERVED TO
BE 2x4 CONSTRUCTION.
"�Y
SIC�MA
DRAFTING &DESIGN
SERVICES, LLC
OLYMP IA, WA
360.464.5373
sigmadrafting.com
z
O
w
_
�_
L
O
�
�
�
�6
�_
�
�
S
v���
f (1
v �
�
O
�
�
�
`�
Q)
(\(�
Q
�O
0
—
�
�
�
�
W
�
L
Drawn: MDC
Designed: MDC
scale: AS SHOWN
Date: 6/3/2024
Job Number:
24006
Sheet Number:
A2.2
11 �f 13
i�
PROVIDE I SF OF VENT PER 150 SF OF ATTIC
STATIC ROOF VENT = 60 SQ IN PER VENT �� � j
■■
SAVE VENT = (4) 2. 125" DIA "BIRD HOLES' = 12 SQ IN PER
BLOCK, 6 SO IN PER FOOT �
CONTINUOUS RIDGE VENT = 12 SO IN PER I LF
NEW ATTIC SPACE SF = 143 I SF
1431 / 150 = 9.54 SF, 1374 SO IN REO'D DRAFTING &DESIGN
SERVICES, LLC
FOR NET FREE, C87 INTAKE C87 EXHAUST
CONTINUOUS RIDGE VENT AVAILABLE: OLYMPIA, WA
78.8 LF x 12 SO IN / LF = 946 360.464.5373
687 / 12 =USE 5£i I_F OF CONTINUOUS RIDGE VENT MIN sigmadrafting.com
FOR SAVE VENT BIRD BLOCKS: w
Q
687 / 12 SO IN /BLOCK = 58 �
l _ F (58) BIRD BLOCKS MIN, PLACE TO PROMOTE CROSS-
VENTII ATION
SEE PLAN FOR ROOF OVERHANGS AT SPECIFIC
AREAS.
ROOFING MATERIAL IS TO BE PER OWNER OR
CONTRACTOR.
z
O
ROOF STRUCTURE IS TO BE PRE -MANUFACTURED
�
TRUSSES @ 24" O.C. UNLESS NOTED OTHERWISE.
j
w
�
-NEW ROOF
ATTIC SHALL HAVE VENTILATION EQUAL TO I SF
BELOW
PER 150 SF OF ATTIC SPACE. VENTILATION SHALL
BE PROTECTED FROM SNOW AND RAIN, AND SHALL
BE COVERED WITH A GALVANIZED WIRE SCREEN.
OPENINGS SHALL BE LOCATED TO PROVIDE CROSS -
VENTILATION.
PROVIDE ATTIC ACCESS PANEL WITH A MINIMUM
ROUGH OPENING OF 22"x30" WITH A TIGHT FITTING,
SELF -CLOSING DOOR. DOOR MUST BE BACKED W/
INSULATION IF LOCATED ABOVE HEATED SPACE.
VERIFY ACCESS LOCATION W/ OWNER.
�_
PROVIDE FULL DEPTH BLOCKING OVER EXTERIOR
WALLS AT EACH BAY. SEE VENTILATION NOTES FOR
�
BIRD BLOCKING COUNT.
�
VERIFY ALL STRUCTURAL INFORMATION
WITH STRUCTURAL PLANS BY OTHERS.
STRUCTURAL PLANS ARE TO OVERRIDE
ANY STRUCTURAL INFORMATION ON
ThE ARCHITECTURAL PLANS
OVERALL ROOD PLAN
Q
s
•
O
Drawn: MDC
Designed: MDC
scale: AS SHOWN
Date: 6/3/2024
Job Number:
24006
Sheet Number:
A2.3
12 �f 13
i�
m
O
m
SIMPSON LS50 EA SIDE
BEAM OR WALL PER
PLAN
z_
,�r
HANDRAIL MIN. I I/2" CLEAR �
DISTANCE FROM WALL �v
m
z_
o�
m N O
m
NOSING OF TREAD
2x 12 STRINGER
2x BLKG
I - I /8" PART BD BULL -NOSE
TREADS GLUED � SCREWED
(INSTALL AFTER ROOF IS ON)
10" MIN
3/4" PLYWOOD RISERS
(3) 2x 12 STRINGERS ' -SEE NOTES SHEET
PROVIDE FIRE BLKG � 7 3/4" FOR FIANDGRIP NOTES
AT TOP AND BOTTOM MAX
USABLE SPACE BENEATH PROVIDE MIN. 36" CLEAR
STAIRS TO BE I/2-11R WIDTH AT STAIRWAYS
CONSTRUCTION W/ 5/8" 2x4 KICK PL
TYPE X GWB
2x BLKG OR JOIST NOTE:
AT FLOOR BELOW GREATEST � LEAST TREAD
� RISER IS NOT TO VARY
MORE THAN 3/8"
TYPIG�L ENGL05�D ST�Ii� D�T�IL
c�
z
u�
0
z
0
Q
w
�/
164"
N
m
m
127 I /2"
BATH DOOM WALL ELEV
38 I /2" 28" 4 I /2" 48„
I"
67 I /2" 4 I /2" 48„
ShOWEI� WALL ELEV
ROOFING MATERIAL OVER
ROOFING PAPER OVER
ROOF SHEATHING
PRE -MANUFACTURED
TRUSSES @ 24" O.C.
I" INSULATION AIR BAFFLE
2x VENTED BLKG EA BAY W/
(3) 2" DIA SCREENED HOLES
GUTTER FLASHING
OVER FASCIA
FASCIA
PER PLAN
O.h. PER PLAN
SIDING PER PLAN
HEADER PER PLAN
OPENING
� �
R-30 GATT
INSULATION
SIMPSON CLIP EACH
TRUSS PER STRUCTURAL
DBL TOP PLATES
2x6 STUDS @ 16" O.C.
W/ R-2 I INSULATION
R- I 0 RIGID INSULATION
AT HEADER GAP
'��t� � � ���►j����r�
•
ROOFING MATERIAL OVER
ROOFING PAPER OVER
PRE -MANUFACTURED ROOF SHEATHING
TRUSSES @ 24" O.C.
I" INSULATION AIR
2x VENTED BLKG EACH BAY
W/ (3) 2" DIA SCREENED HOLES
GUTTER FLASHING
OVER FASCIA
PER PLAN
O.H. PER PLAN
SIDING PER PLAN
HEADER PER PLAN
OPENING
�L
SIDING PER PLAN
(N) WALL S1IEATFIIN
CONTINUOUS RIM JOIST
(E) DBL TOP PLATES
(E) WALL S1IEATFIING
VERIFY WITH STRUCTURAL
EXISTING INSULATION
R-49 GATT
INSULATION
GWB
SIMPSON CLIP EACH
TRUSS PER STRUCTURAL
DBL TOP PLATES
2x6 STUDS @ 16" O.C.
W/ R-2 I INSULATION
R- I 0 RIGID INSULATION
AT HEADER GAP
- • � • rIi]�i.l� •
I /2" GWB
3/4" TAG
FLOOR SHEATHING
(N)FLOOR JOISTS
PER STRUCTURAL
I �(N) 5/8" GWB
�(E) I /2" GWB REPLACE
AS NEEDED
EXISTING STUDS
� ��—
•
CONNECTION PER
STRUCTURAL
5/4x8 FASCIA BD
W/ K-LINE GUTTER \
CONTINUOUS RIDGE VENT
SKYLIGHT LOCATION PER OWNER/
CONTRACTOR
ROOF CONSTRUCTION:
ROOFING PER OWNER OVER
30# BUILDING PAPER OVER
I /2" ROOF 511EAT111 NG OVER
PRE-ENGINEERED TRUSSES @ 24" O.C. W/
R-49 BLOWN -IN INSULATION AND
5/8" GWB AT INTERIOR
� 6 MIL BLACK VAPOR BARRIER, LAP
12" AT SEAMS � UP FDN WALL
BUILDING SECTION 'A'
EXTERIOR WAI I CONSTRUCTION:
SIDING PER PLAN OR OWNER OVER
WEATHER RESISTIVE BARRIER OVER
I/2" WALL SHEATHING OVER
2x6's @ 16" O.C. W/
R-2 I GATT INSULATION AND
I /2" GWB AT INTERIOR W/
CLASS I OR I I VAPOR RETARDER
STRUCTURAL INFO NOTE
VERIFY ALL STRUCTURAL INFORMATION
WITH STRUCTURAL PLANS BY OTHERS.
STRUCTURAL PLANS ARE TO OVERRIDE
ANY STRUCTURAL INFORMATION ON
THE ARCHITECTURAL PLANS
DOOR SGHEDULE
LABEL
QTY
FLOOR
SIZE
R/O
DESCRIPTION
COMMENTS
2468
1
1
2468 R IN
30"X82 1/2"
HINGED -DOOR PO4
2668
2
2
2668 L IN
32"X82 1/2"
HINGED -DOOR PO4
2668
2
2
2668 R IN
32"X82 1/2"
HINGED -DOOR PO4
2868
3
2
2868 L IN
34"X82 1/2"
HINGED -DOOR PO4
2868
3
2
2868 R IN
34"X82 1/2"
HINGED -DOOR PO4
3068
1
1
3068 R EX
38"X83"
EXT. HINGED -DOOR E21
3068
1
2
3068 L IN
38"X82 1/2"
HINGED -DOOR PO4
5068
1
1
5068 R IN
62"X82 1/2"
SLIDER -DOOR PO4
1NINDOIN SGHEDULE
LABEL
QTY
FLOOR
SIZE
R/O
DESCRIPTION
COMMENTS
11040
1
2
11040
23"X49"
FIXED GLA55
1268
2
1
1268
15"X81"
FIXED GLA55
2046
2
2
2046
25"X55"
FIXED GLA55
2340
2
2
2340
28"X49"
SINGLE CASEMENT-HL
2340
2
2
2340
28"X49"
SINGLE CASEMENT-HR
2840
1
2
2840
33"X49"
SINGLE CASEMENT-HL
3040
2
2
3040
37"X49"
SINGLE CASEMENT-HL
3050
1
2
3050
37"X61"
FIXED GLA55
31036
1
2
31036
47"X43"
LEFT SLIDING
4036
1
2
4036
49"X43"
LEFT SLIDING
4640
1
2
4640
55"X49"
FIXED GLA55
4640
1
2
4640
55"X49"
LEFT SLIDING
5040
1
2
5040
61 "X49"
FIXED GLA55
5040
3
2
5040
61"X49"
LEFT SLIDING
6020
1
2
6020
73"X25"
FIXED GLA55
"�Y
SIC�MA
DRAFTING &DESIGN
SERVICES, LLC
OLYMP IA, WA
360.464.5373
sigmadrafting.com
z
0
w
S
rev
V J
�
J
�6
�
Q�
�
(�
l(i
�
�
�
�
S
�
�
�
Q
U
-�
O
�
�
Q)
�
O
4�
m
o
�
U
p
�
�
�
W
�
V '
�
Drawn: MDC
Designed: MDC
scale: AS SHOWN
Date: 6/3/2024
Job Number:
24006
Sheet Number:
A3.0
13 �f 13
i�