APPROVED BLD BLD2023-1032+Architectural_Plan+8.15.2023_2.37.01_PM+3727181ABBREVIATIONS:
PROJECT INFORMATION:
0
BASEMENT DEMO PLAN
SCALE: 1/4" = V-0"
REMOVE (E) FIXTURES
DEMO (E) WALL & DOOR
'1f:>
1ST FLOOR DEMO PLAN
SCALE: 1/4" = V-0"
REMOVE (E) WASHER &
DRYER. RELOCATE TO
BASEMENT
REMOVE PORTIONS OF
WALL AS SHOWN
ACH
Air Changes per Hour
ADJ
Adjacent
ADU
Accessory Dwelling Unit
BD
Board
BM
Beam
BOT
Bottom
BTWN
Between
CANT
Cantilever
CFM
Cubic Feet per Minute
CLNG
Ceiling
CONT
Continuous
D
Deep
DF
Douglas Fir
DN
Down
DP
Deep
DW
Dishwasher
EA
Each
EF
Exhaust Fan
EG
Egress
(E)
Existing
EXT
Exterior
FRZR
Freezer
FTNG
Footing
GWB
Gypsum Wall Board
H
High
HB
Hose Bibb
H.C.
Hollow Core
HDR
Header
HORIZ
Horizontal
HT
Height
IBC
International Building
Code
INT DES Interior Design(er)
IRC
International Residential
Code
LIN
Linen
MAX
Maximum
MIN
Minimum
MTL
Metal
(N)
New
N/A
Not Applicable
O.C.
On Center
PR
Pair
PT
Pressure Treated
REF
Refrigerator
REQ'D
Required
S&R
Shelf and Rod
S.C.
Solid Core
SD
Smoke Detector
SECT
Section
SG
Safety Glazing
SQ
Square
STOR
Storage
STV
Stove
T.O.W.
Top of Wall
TYP
Typical
U
U Value
UNO
Unless Noted Otherwise
VERT
Vertical
VG
Vertical Grain
VTO
Vent to Outside
W
Wide
W/
With
W/D
Washer/Dryer
WD
Wood
W.H.
Water Heater
#
Pound
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
■A separate permit is required for the Plumbing.
Please obtain a plumbing permit from the City of0
Edmonds.
■ I
iA separate permit is required for the elevator
from Labor and Industries.
APPROVED
PLANS MUST BE
ON JOB SITE
Owner:
GARY KINDNESS
212 SKYLINE DR
EDMONDS, WA 98020
Project Address:
212 SKYLINE DR
EDMONDS, WA 98020
Parcel:
00520300000700
Legal:
MT BAKER VIEW ADD BLK 000 D-00 -
ALL LOT 7 & N1/2 LOT 8
Project Description:
Interior remodel to add residential elevator
Codes:
2018 International Residential Code
2018 International Building Code
2018 Washington State Amendments
2018 Washington State Energy Code
PROJECT TEAM:
BUILDING DESIGNER:
Katherine Zeim
K Zeim Home Design
1329 N 47th St, #31348
Seattle, WA 98103
kathy@kzeimdesign.com
(206) 850-9323
DRAWING INDEX:
A1.0 COVERSHEET & DEMO PLANS
A2.0 PLANS & FRAMING DETAILS
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
City Of Edmonds
Building Department
Work REMODEL AND ELEVATOR SHAFT
Address 212 SKYLINE DR
Owner KINDNESS
--------------
Approved Date! 8/31/2023
------------------
--------------------
Building Official
--------------------------------------
------------- ----------------------
Permit Number BLD2023-1032
REVISIONS
DATE - PAGES CHANGES
REV1
REV2
REV3
REV4
REV5
K Zeim I Home Design
P.O. Box 31348
Seattle, WA 98103
(206) 850-9323
kathy@kzeimdesign.com
KINDNESS
ELEVATOR
212 SKYLINE DRIVE
EDMONDS, WA 98020
PERMIT
REV #: DATE: DESCRIPTION:
RECEIVED
Aug 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
COVERSHEET
Al 00
AUGUST 14, 2023
(E) STEAM SHOWER EQUIP @
UNDERSIDE OF STAIR.
ASSESS VIABILITY OF HOOKING
UP TO (N) SHOWER
4'-7"
DIMENSIONS TO
FACE OF DRYWALL,
UNO
ELEVATOR ANCHOR
FRAMING
'-84"+/-
ELEVATOR
r9-41
DOOR RECESSED TOMATCH RECESS AT 36" DRR
NORTH SIDE OF
ELEVATOR 3ATH
0 2'-8"50 21_8
30" DP.
EXISTING iv
DRAIN O
+ r
�M
1
RELOCATE (E) WASHER & zo W D LAUNDRY
DRYER FROM 1ST FLOOR VTO
EXISTING
HOOKUP`
10'-91,
BASEMENT PLAN
SCALE: 1/4" = V-0"
8 7 6
B
P
LU
�UU
6l
g
�
J
O
OVERHEAD
HOISTING PULLEYS
120VAC AND
PHONE
JUNCTION BOX
EITHER SIDE
SLIDING CAR GATE
WITH POISTION
SENSOR
EXTRUDED
ALUMINUM
GUIDE RAILS
IJ.
ELEVATOR FRAMING
SCALE: 1/4" = V-0"
2x4 F
W/ 2,,
2x RI
OF C
(N) E
ELEVATOR SECTION
SCALE: 1/4" = V-0"
DIMENSIONS TO ELEVATOR ANCHOR
FACE OF DRYWALL, FRAMING
UNO
30" x 60" SHOWER 4'-7' /6-2"
W/TEMPERED GLASS
ENCLOSURE
�bN 12" CAB'S
a, o ELEVATOR
v X4"-7
36" DR �bN
rn '
PANTRY
+ ATTIC ACCESS00
C? 22" X30" MIN. ARCHED
N OPENING
1
CD 5'-102L 3,-9„ 1'-101r
i0
PLAN NOTES:
1. Dimensions to finish face of (wood stud & drywall)
walls, face of concrete, or centerline of column, UNO.
2. Contractor to notify building designer of any
discrepancies in the drawings prior to proceeding with
work in the affected area.
3. Insulate existing exterior wall stud cavities exposed
during construction w/R-15 batt insulation or to full
depth of cavity.
4. A minimum of 90% of permanently installed lamps
in the lighting fixtures in the addition shall be
high -efficacy lamps.
5. EXHAUST FANS vent to outside. All exhaust fans
vent to outside. Exhaust fan terminations may must
meet requirements of SRC 1506.2 and not terminate
within 3' of property lines, operable or inoperable
openings, or within 1 O' of mechanical air intakes
except when the termination is 3' above the intake.
6. ELEVATOR to be Advantage Elevator EZ6F-RH,
battery operated elevator
SYMBOLS:
NEW WOOD STUD FRAMING:
2X4 @ 16" O.C. @ INTERIOR, UNO
EXISTING WALL (2x4 STUD FRAMING
OR 6" CONCRETE)
EXHAUST FAN (MIN. CFM,
50 INTERMITTENT, UNO)
1ST FLOOR PLAN
2 SCALE: 1/4" = V-0"
4 3 2 1 8 - 6 5 4 3 2
SPECIFICATIONS AND DIMENSIONS
SUBJECT TO CHANGE WITHOUT NOTICE
HOISTWAY BY
OTHERS
FRAMING AS
REQUIRED
'ERLOCK
)ISTWAY
i INCLUDED
1*1;1; 12Le7
Features:
Battery Powered: 24 VDC Control System Automatic up/down controls
Rated Load: 500 Ibs Key Lock on controls
Speed: 15-18 fpm Emergency Stop Switch and Alarm
Max. Travel: 21' Status LED
Car Size: 42"W x 41 "D x 76"H Winding Drum Drive with two 1/4" aircraft cables
Overhead Clearance: 86" Min. Slack Cable Safety Device
Powder Coated Metal: Gray White Final Limit Switches
Vision Panels: Clear Acrylic Electromechanical Interlocks on Hoistway Doors
Car Light: Recessed LED Door Position switch on Sliding Car Gate
Telephone: Inside Telephone Cabinet
)OR PLATE HT
MAIN FLOOR
,OR PLATE H7
DWER FLOOR
3
I
B
n
48"
144„—��� 182,.2 X 6
144„
D
WALL STUD
42"
INSIDE
c
L^
L.
W
'I!o 1-I
H
v Z
w
Q
2„
2"
3
04SO
�222"
OU
_ O
NAME DATE $layiny Home Corporation
DESIGNS TO COMPLY DRAWN m61MI? 2507 Maoondand
WITH ASME A17,1 11w.omllle, M054701
36" CHECKED 816-360.2427
AR GATE PART 5.3 - 2019 WHEN ENG APPR, www.etaylnphome.00m
PROPERLY INSTALLED MFOAPPR. TITLE:
OPENING
V
O.A.
36" YIOPRIIrARY AND CONFIDENTIAL COMMENTS:
ONGHOISTWAY DOOR DRAWITHEINFORIN RTVOF SIZE DWG. NO. REV
MA THE
DRAWNOOME SOLEPROP
IS LEFR'ONED
OPENING STAYING HOMEN AN B TYP - EZbF-RH
N°ARTRTOR433Aw
OL
WRHOUT THE WRITE PERVDSION OF
STAvROHINTEooME coRPolnnon s SCALE: 1:64 WEIGHT: SHEET 2 OF 2
n ELEVATOR FRAMIIVG
SCALE: 1/4" = 1'-0"
i 3'_91
1ARCH ELEVATION
SCALE: 1/4" = V-0"
3
tp I I
K Zeim I Home Design
P.O. Box 31348
Seattle, WA 98103
(206) 850-9323
kathy@kzeimdesign.com
KINDNESS
ELEVATOR
212 SKYLINE DRIVE
EDMONDS, WA 98020
PERMIT
REV #: DATE: DESCRIPTION:
RECEIVED
Aug 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
PLANS
A200
AUGUST 14, 2023