Loading...
APPROVED ENG PLN BLD-RESUB 1-BLD2022-1474+Architectural_Plan+4.20.2023_11.58.27_PM+3496702O 1 v APPROVAL STAMP PAGE PERMITTING & DEVELOPMENT BUILDING DIVISION 121 5th Avenue N P: 425.771.0220 www.edmondswa.gov PLEASE KEEP WITH THE PLANS City Of Edmonds Building Department Work BASEMENT REMODEL Address 19532 88TH AVE W ---------------------------------------- Owner YBARRA Approved Date Building Official Permit Number -------------- 5/2/2023 ----------------- ---------------- 4,eI4 gl ox�W'd BLD2022-1474 OBTAIN ELECTRICAL ALL WORK SUBJECT APPROVED PERMIT FROM TO FIELD PLANS MUST BE STATE LABOR & INSPECTION FOR ON JOB SITE INDUSTRIES CODE COMPLIANCE iSEPARATE PLUMBING PERMIT;,interconnected Smoke Alarms Are ARequirement! REQUIRED FOR THIS PROJECT.OfThis Permit lnAccordance With R314.2.2 RESUB Apr 21 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT APPROOV�E�D� BY PLANNING Apr 24 2023 ENGINEERING DIVISION APPROVED AS NOTED MY U%gas',eot 05/03/2023 VV Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. NOTE: This Stamp page must remain with the city approved plans at all times. Failure to have this Stamp page with the City approved plans could result in delay of the inspections including the FINAL inspection. If lost please contact the city as soon as possible to find a solution. Thank You. 8 8�''' �Q • W w SNAIV1 door ;Tww Moor fto vs£ � N 1 14 .go : mL 2 = 12f5 idcYl a M1 L = Motk!ev--i vv- laW scrun�d o'ev log le 5 rrf ?LAN (wdi4imetl Use: Mb4W r - i n - LAW AmAvew '{bars d �aiw�e 8e�i��and 10165Z 88-f"' A-W. W. C--Amod 5 t wit- " W (o Peujevk- b)vrtac,+: ` ",rl70�if bArcal -l-herot�ings�a� k&imai 1 • lows RESUB Apr 21 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 17'-7Y2" 1.- 6'-5" 1.- 30'-4 2„ Existing Conditions - Upper ANDREW YBARRA & JAIME BECKLAND 19532 88TH AVE W EDMONDS, WA 98026 PROJECT CONTACT: ANDREW YBARRA (206) 370-1146 54'-5" Scale: 1/4"=1'-0" NORTH (9 SCOPE OF WORK: ADD MOTHER-IN-LAW APARTMENT. DEMO EXISTING BATHROOM, RELOCATE GAS FURNACE AND ADD NEW BATHROOM, OFFICE AND REC ROOM. ENCLOSE EXISTING LAUNDRY / UTILITY ROOM. zo CV RES U B Apr 21 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Al SHEET 2 OF 7 Existing Conditions - Basement ANDREW YBARRA & JAIME BECKLAND 19532 88TH AVE W EDMONDS, WA 98026 PROJECT CONTACT: ANDREW YBARRA (206) 370-1146 UPPER FLOOR ABOVE --------------------------------------- 54'-1 " , NORTH Scale: 1/4"=1'-0" (9 0 CV RESUB Apr 21 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Al SHEET 3 OF 7 CV CV 0 —,� UPPER FLOOR ABOVE— � — — 16'-2— — " DRAIN EGRESS WINDOW, PER IRC 310.1 AND 310.2 �FO MAX U-VALUES SEE SHEET 7 OF 7 — EGRESS WINDOW WELL, PER IRC 310.2.3. SEE DETAIL SHEET OF 7 -------- ---- 3'-3" IA4 13'-1" --- — — --- N) WINDOW L— — A L GHT PARTIAL HEIG FLAT STUD FURRED I (E) ELECTRICAL PANEL W/ METER OUTSIDE I — — _ FLAT STUD FURRED OUT WALL 0/ FDN OUT WALL O/ FDN II (N) REC ROOM O M , (E) BEDROOM 2x4 STUD - (N) LIVING ROOM --J � � WALL, TYP. - I I I Q 0 PARTIAL HEIGHT 6x12 BEAM ABV — � 0 2x6 WALL (N) TSTAT 4 FURRED OUT I I — — — I � � LL @ UNDER BEAM 0 ALL 0/ FDN oe 9'-0 2 3'-6%" J `� 4x6 POST / (N) TSTAT (3) 2x4 UP / T 2 a X 6 $4x6 POST 777(E) 2x4 STUD WALE (ELTAIR ABOVE HANDRAIL :PER IRC 2'-10%" R301.5;R312;31 x REMOVE WALL T 4x6 POST 3 2x4 O I 0 FURRED OUT RELOCATE GAS (N) POCKET DOOR SEE & DOOR i STACKING, W/D 8'-0„ I FORCED AIR NEW N N DOOR SEE NOTE NOTE SHEET 7 OF 7 1 - O FURNACE ��% 1\ 28x s8 PLUMBING N MIL SHEET 7 OF 7 WALL WT E B\ H KITCHEN I 0 8 X s (N) OFFICE �� GAS FURN N�- B , 2 6 3-1/ o (N) LAUNDRY FUTURE STOVE W/ HOOD w N DOUBLE 0 2x4 WALL O FUTURE FRIDGE 2x4 STUD WALL U) o ON TOP OF FDN o O o 2'- " _ -� ' v o o o I z 2x FURRING (N) WATER SHUT OFF FOR PRIMARY RESIDENCE 8'-9" f 3'-011 QI 5" ^ - - Basement Floor Plan ANDREW YBARRA & JAIME BECKLAND 19532 88TH AVE W EDMONDS, WA 98026 PROJECT CONTACT: ANDREW YBARRA (206) 370-1146 32'-6" REMOVE & INFILL D00 7'-0" 011 NORTH - (Z:L1_ Scale: 1/4"=1'-0" SCOPE OF WORK: ADD MOTHER-IN-LAW APARTMENT. DEMO EXISTING BATHROOM, RELOCATE GAS FURNACE AND ADD NEW BATHROOM, OFFICE AND REC ROOM. ENCLOSE EXISTING LAUNDRY / UTILITY ROOM. (N) MINI SPLIT \ EVAPORATOR UNIT(S) FOR ADU (E)WINDOW. IF ` REP ACED MUST MEET MAX U-0.30 (N) MINI SPLIT CONDENSER UNIT FOR ADU CV CV (E)WINDOW. IF REP ACED MUST MEET MAX U-0.30 I I (N) ELECTRICAL SUB -PANEL FOR ADU EGRESS DOOR, (E) WATER SHUT OFF, PER IRC 311.2 (N) WATER SHUT OFF 1'-3" FOR ADU ONLY Al 13'-1" RESUB EXISTING WALL Apr 21 2023 CITY OF EDMONDS DEVELOPM ENT SERVICES NEW WALL NEW PARTIAL HEIGHT WALL DEMO WORK Al SHEET 4 OF 7 i i A NVK1ri U-U `rA lv uLnfVI nI Basement Framing Plan PREVIOUS FRAMED OPENING Scale: 1/4"=1'-0" (B ANDREW YBARRA & JAIME BECKLAND 19532 88TH AVE W EDMONDS, WA 98026 PROJECT CONTACT: ANDREW YBARRA (206) 370-1146 RESUB Apr 21 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Al SHEET 5 OF 7 4 Basement Reflected Ceiling Plan Scale: 1/4"= V-0" NOTE: ALL EXHAUST SYSTEMS SHALL BE INSTALLED PER THE 2018 IRC CHAPTER 15 ANDREW YBARRA & JAIME BECKLAND 19532 88TH AVE W EDMONDS, WA 98026 PROJECT CONTACT: ANDREW YBARRA (206) 370-1146 NORTH �R T 100 CFM SD co RECESS CAN LIGHT SURFACE MOUNTED LIGHT SWITCH EXHAUST FAN (SEE NOTE) HOOD EXHAUST FAN (FUTURE) SMOKE ALARM CARBON MONOXIDE ALARM RESUB Apr 21 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Al SHEET 6 OF 7 NOTE (1) IRC SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS. I I R301.5 31-0" PREMANUFACTURED WINDOW WELL, INSTALL PER MFGR 0 CV — o a d I III III i - Egress Window Well *PER IRC R310 IRC R310.2.3 WINDOW WELLS. 1. GUARDRAILS SHALL BE DESIGNED TO RESIST A 200 LB THE HORIZONTAL AREA OF THE WINDOW WELL SHALL BE NOT LESS CONCENTRATED LOAD ON TOP RAIL AND 50 PSF ON ALL GUARDRAIL THAN 9 SF, WITH A HORIZONTAL PROJECTION AND WIDTH OF 36". THE INFILL COMPONENTS AREA OF THE WINDOW WELL SHALL ALLOW THE EMERGENCY ESCAPE AND RESCUE OPENING TO BE FULLY OPENED. R312 NOTE (2) IRC SECTION R314 SMOKE ALARMS R314.2.2 ALTERATIONS, REPAIRS AND ADDITIONS. WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, THE INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR THE NEW DWELLING. R314.3 LOCATION. SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING GRADE LOCATIONS: 1. IN EACH SLEEPING ROOM. 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. WASHED GRAVEL DRAIN, TIE INTO J\ TIGHT LINE OR DRAIN FIELD Scale: 1/2"=1'-0" R310.2 WINDOW WELLS. THE MIN. HORIZONTAL AREA OF THE WINDOW WELL SHALL BE 9 SF, WITH AT MIN. HORIZONTAL PROJECTION AND WIDTH OF 36". THE AREA OF THE WINDOW WELL SHALL ALLOW THE EMERGENCY ESCAPE AND RESCUE OPENING TO BE FULLY OPENED. ANDREW YBARRA & JAIME BECKLAND 19532 88TH AVE W EDMONDS, WA 98026 PROJECT CONTACT: ANDREW YBARRA (206) 370-1146 R314.4 INTERCONNECTION. WHERE MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT IN ACCORDANCE WITH SECTION R314.3, THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL ALARMS SOUND UPON ACTIVATION. i R314.5 COMBINATION ALARMS. COMBINATION SMOKE AND CARBON MONOXIDE ALARMS SHALL BE PERMITTED TO BE USED IN LIEU OF SMOKE ALARMS. NOTE (3) IRC SECTION R315 CARBON MONOXIDE ALARMS R315.2.2 ALTERATIONS, REPAIRS AND ADDITIONS. WHERE ALTERATIONS, REPAIRS AND ADDITIONS REQUIRING A PERMIT OCCUR, THE INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH CARBON MONOXIDE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. R315.3 LOCATION. CARBON MONOXIDE ALARMS IN DWELLING UNITS SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS, WHERE A FUEL BURNING APPLIANCE IS LOCATED WITHIN A BEDROOM OR ITS ATTACHED BATHROOM, A CARBON MONOXIDE ALARM SHALL BE INSTALLED WITHIN THE BEDROOM. R315.4 COMBINATION ALARMS. COMBINATION CARBON MONOXIDE AND SMOKE ALARMS SHALL BE PERMITTED TO BE USED IN LIEU OF CARBON MONOXIDE ALARMS. R315.5 ITERCONNECTIVITY. WHERE MORE THAN ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT IN ACCORDANCE WITH SECTION R315.3, THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING UNIT. PHYSICAL INTERCONNECTION OF CARBON MONOXIDE ALARMS SHALL NOT BE REQUIRED WHERE LISTED WIRELESS ALARMS AR INSTALLED AND ALL ALARMS SOUND UPON ACTIVATION OF ONE ALARM. 1. GUARDS SHALL BE LOCATED AT ANY OPEN -SIDED WALKING SURFACE MORE THAN 30 INCHES ABOVE FLOOR OR GRADE, MEASURED VERTICALLY. R311.7.8 1. LOCATE HANDRAILS 34"-38" ABOVE STAIR NOSING 2. GRASP DIMENSIONS OF HANDRAIL = 1 1/4" TO 2". 3. HANDRAILS SHALL BE CONTINUOUS OR TERMINATE @ NEWEL POSTS R312.1.3 OPENING LIMITATIONS REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4" IN DIAMETER EXCEPTION: 1. THE TRIANGULAR OPENINGS AT THE OPEN SIDE OF STAIR, FORMED BY THE RISER,TREAD AND BOTTOM RAIL OF A GUARD, SHALL NOT ALLOW PASSAGE OF A SPHERE 6" IN DIAMETER 2. GUARDS ON THE OPEN SIDE OF STAIRS SHALL NOT HAVE OPENINGS WHICH ALLOW PASSAGE OF A SPHERE-4_3/8" IN DIA. (PRESCRIPTIVE II FROM WSEC) MAX. FENESTRATION U-VALUE: U-0.30 MAX. SKYLIGHTS: U-0.50 MIN. INSULATION CEILING: R-49/R-38ci MIN. INSULATION WALLS: R-21 int MIN. INSULATION FLOORS: R-30 MIN. INSULATION SLAB ON GRADE: R-10, 2' DOOR NOTE: 100 SQ IN OF MAKE UP AIR REQUIRED AT THESE LOCATIONS. UNDER CUT BOTTOM OF DOOR(S) 3" ABOVE FINISHED FLOOR OR ADD 100 SO IN GRILL INTO DOOR(S) TO ALLOW FOR MAKE UP AIR RESUB Apr 21 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 SHEET 7 OF 7