2023-04-05-6907.21 Residence-SW448452-REVOTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing CONSTRUCTION INSPECTION REPORT Report Number: SW448452-REV Project Name: 6907.21 Residence Job Number: 23-0206 Project Address: 6907 160th St SW, Edmonds Permit: BLD2021-0705 Client Name: Reign City Contractors Inspections Performed Steel Decking ❑ Other (specify): Structural Steel Fabrication ❑ Structural Steel Erection ❑� Inspector and Date Remarks John Fraser On site at for ORA at contractor's request for inspection of structural steel welding. April 5, 2023 Inspection covers the requirements set forth in engineer's specifications and approved construction documents. -Welding inspection was performed on the following: 1. PSL Saddle to wide flange (WF) beam 2. Wood post clips to beam bottom flange Reference: SideSway Engineering project # 21019.03, Sheet S4.2 Detail specified post -clips to be fit and welded horizontally oriented on the back of the PSL saddle Contractor needed to install the clips vertically, on the bottom of the WF beam This scope of work is in non-conformance with structural documents pending Engineer of record review. Does not Conform NOTE FROM OFFICE: Report is now in conformance. Please see attached email from Engineer dated 04/19/2023. Conforms ���JJ Date: 2023.04.20 Copies to: L/�r ,c ow ❑ Client ❑d Engineer ❑ Others Technical Responsibility: 07:45:39 -07 00 ❑ Owner ❑d Contractor ❑ Architect ❑4 Building Dept Isaac Ruoff, Project Manager This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report except in full, without written permission from our firm is strictly prohibited. 6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725-4600 - Fax (206) 723-2221 Form No.: ADMIN-63-05 (Rev 10/10) Page 1 of 1 Amber Payseno From: Chris Bernards <chrisb@sideswayengineering.com> Sent: Wednesday, April 19, 2023 1:41 PM To: Amber Payseno; 'City of Edmonds (Eric Carter)'; 'City of Edmonds (Leif Bjorback)'; 'Jon Chafe' Cc: John Fraser; 'Josh Dreher' Subject: RE: 6907.21 Residence (Permit #: BLD2021-0705) Ladies and gentlemen — We've reviewed the non -conforming special inspection report provided by Otto Rosenau as well as pictures of the connection as built from the contractor. After reviewing the loads, we have determined that the kerf plate as installed is sufficient structurally. The kerf plate had to be installed lower than the WF beam because of the floor step and this is acceptable. Is anything further needed from Sidesway Engineering to resolve this issue? Chris Bernards, PE, SE, LEED AP Principal SIDE 5WAY ENGINEERING (425)673-4160 http://www.sideswayengineering.com From: Amber Payseno[mailto:amber.payseno@ottorosenau.com] Sent: Wednesday, April 12, 2023 10:23 AM To: Chris Bernard; City of Edmonds (Eric Carter); City of Edmonds (Leif Bjorback); Jon Chafe Subject: 6907.21 Residence (Permit #: BLD2021-0705) Attached are report(s) for the referenced project. Amber Payseno Administrative Assistant Otto Rosenau & Associates, Inc. Geotechnical Engineering, Construction Inspection & Materials Testing 6747 Martin Luther King Jr. Way South, Seattle WA 98118 Phone: (206) 725-4600 To schedule an inspection, you can click here or text (833) 568-9572