Loading...
APPROVED ENG BLD PLN-RESUB 2 -PLAN SET+4.27.2022CONSTRUCTI N ENTRANCE O II I4ILTER FENCE AND ONSTRUCTION E I \\ OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING EN C I \ ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY \ UTILITIES MAY REQUIRE A SEPERATE PERMIT. O �- \ \ EXISTIN I DOWN POUT I DRAI TO I I NEW ECK I I o I fJ , Sheet Index A1.1 Site Plan + Notes A2.1 Lower Floor Plan TREE-7- - \ \ A2.2 Upper Floor Plan \ A2.3 Roof Plan A3.1 Elevations A3.2 Elevations + Window Schedule - I � A4.1 Wall Details 80.0' EN I_ I - S1.0 Structural Notes � O II S2.0 Foundation Plans S2.1 Upper Floor Framing Plans EXISTING Jo- IASPHALT S3.0 Structural Details DRIVEWAY C �s 26' " I 8' ISTING I 80 DOWNSPOUT I °' I - I cp XIST.CONC. I ' DRAINS TO ' 33 - louse to PL DRIVEWAY A SPLASH BLOCK ' WALKWAY - E 0.5 E 1209.8 = o EL. 210 B o0 -- - - - - - -- p 0 - - - I I, NEW DECK W/ cal I I NEW ADDITION a� \ II/ NEW - - J DOWNSPOUT DRAINS To a = SPLASH LOCKS ------- I 3 6 J II I � I EM ORY STOCK PILE. EXISTING I NOTE; TO BE COVERED DOWNSPOUT I WITHIN 24 HRS. DRAINS TO I SPLASH BLOCK I I �II 1 NOTE: INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO APPROVED PLANS, CITY OF EDMONDS STANDARD DETAILS, AND ALL OTHER MEASURES THAT MAY BE REQUIIRED DURING CONSTRUCTION. NOTE: ALL DISTURBED AREAS TO BE COMPOST AMENDED PER 2014 SWMMWW BMP T.5.13. NOTE: FILTER SOCKS WILL BE ADDED TO ANY CATCH BASINS DOWNSTREAM FROM CONSTRUCTION SITE. CITY STANDARD DETAIL ER-902. NOTE: USE ORANGE PROTECTIVE FENCING TO PLACE TO PROTECT TREE DRIP LINES AND OTHER AREAS THAT REQUIRE LOW IMPACT FOR GROUND WATER INFILTRATION. AVERAGE GRADE, DRAINAGE AND SITE 2 ROTECTION PLAN A1.1 NEW LIVING SPACE N FOOTING BELOW DRAIN TO DRYWELL I o EXISTING SHEDR TO BE REMOVED NEW CONC. 20 PATIO AND a-) WALKWAY 11.8 (SEE 1/A2.1) D SCALE 1/16" = 1'-0" 0 16 32 O O I O CLOSEST PATIO CAN BE -8" I I SET�K II EXISTING lo SINGLE b FAMILY - HOME IJ� I �_'RlMOVE EXIST N PAT 110 ItL21�+1 aw \X�iSS � F CO LU of Record of Short Subdivision Recording # (709160402 \ Includes easements ) EL 210.0 ®1 7'-2" IL ROOF _4 EAVES I EXTERIOR WALLS EL. 211 29'-2 / I I . SANITARY EWER Eq M NT _ / I �I Record of Short Subdivision Recording # 7709160402 Includes easements) I of OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE ALL DISTURBED SOILS SHALL BE COMPOST AMENDED PER CITY OF EDMONDS STANDARD DETAIL SD-642 OR APPROVED EQUAL. APPROVED BY PLANNING lz,�e May 06 2022 SITE PLAN ENGINEERING DIVISION APPROVED AS NOTED 05/11 /2022 NO STORMWATER MANAGEMENT SYSTEM REQUIRED AT THIS TIME. IF NEW AND/OR REPLACED IMPERVIOUS SURFACE EQUALS 2000SQFT OR GREATER, A STORMWATER MANAGMEMENT SYSTEM MAY BE REQUIRED PER CITY CODES AND STANDARDS Zone RS-12 Corner Flag Setbacks: Required Actual Front 25' 66' Sides 10' 10' Rear 25' 73'-4" Other ------------- 25 22'-10" Height SCALE 1/16" = 1'-0" 0 16 32 O O I O General Notes 1. All new work, including Mechanical and Electrical work shall comply with the 2018 International Residential Code, and respective trades codes, latest edition in effect. 2. All workmanship shall be performed in a manner commensurate with a standard of craftmanship expected of journeymen construction personnel. 3. Do not scale drawings. Written dimensions govern. 4. Dimensions at new construction are to face of finish or face of concrete unless noted otherwise. 5. Dimensions at existing construction are to face of finish unless noted otherwise. 6. All smoke detecters shall be hard wired. 7. Insulate with high density batt insulation when existing walll and ceiling cavity is opened during construction. Code Notes cont. Impervious Surface Existing House 1660 SF Existing Walks 160 SF Existing Driveway concrete 420 SF Existing Driveway asphalt 1265 SF Existing Patio, deck and shed to be removed 1520 SF New Additon 655 SF New Patio 1180 SF Replace section of exist concrete Driveway 60 SF Repace and New Total 1895 SF Averaae Grade Calculation - see 2/A1 A = 210.5 B = 209.8 C = 213.6 D = 211.8 AVERAGE GRADE = 211.4 APPROVED PLANS MUST BE ON JOB SITE City of Edmonds Building Department APPROVED Plans ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department Work ADDITION AND DECK Address 7622 175TH ST SW ---------------------------------------------- Owner ROBERSON --------------------------------------------------------------- Approved Date' Building Official Permit Number BLD2022-0066 Project Information Applicant Shauna Roberson Owner Shauna Roberson Aaent of owner and main contact Loren Hill 206-910-7438 Loren.Hill@gmail.com Assessors Parcel Number Property Description SEC 07 TWP 27 RGE 04W 80FT OF E 271.60FT OF S1/2 S1/2 NE1/4SE1/4 EXC N 1 OFT & EXC S 118.23FT THOF AKA LOT A OF CITY OF ED SP REC AFN 7709160402 Property Address 7622 175TH ST SW EDMONDS, WA 98026 Project Description Add Lower floor addition to existing house. The scope to include new bedroom, expanded family room, powder room, storage room and 3/4 bath. Record of Short Subdivision Recording # 7709160402 ( Includes easements ) Code Notes Zoning: Set back: Front Yard Side Yard Rear Lot Coverage allowed Existing House and eaves New addition + Deck Remove Shed Total lot coverage = Building Height Allowed Height Calculations: Average Grade = 210.6' Max Height = 235.6' Lot Size RS-12 25 Feet 10 Feet 25 Feet 35 percent of total lot area 1,602 SF 1,065 SF (130) SF 2.407/10.019 = 24% 25 Feet A=210.0', B=209.8, C=211.6', D=211.1' 15,246 SF x Building Area: Existing Heated: Upper Floor Area: 1588 SF Lower Floor Area: 884 SF Proposed New Lower Area 715 SF Unheated: Attached Garage: 572 SF Building Code: Regulating Code: 2018 IRC as amended by the State of Washington and the City of Edmonds 2018 Washington State Energy Code Edmonds Community Development Code Title 19 Occupancy: R-3, Single Family Residence Construction Type: V-N Seismic Zone: 3 Wind Exposure: Exposure B Energy/Mechanical: Energy Code Compliance: New construction will adhere to 2018 Washington State Energy Code. When porttions of existing interior cavities are opened, best effort will be used to comply with Energy Code Energy Credit: Option 1.3 = 0.5 credit Option 3.2 = 1.0 credit Bosch Model B0VA-60HDN1-M18M = HSPF of 9.5 Option 4.1 = 0.5 credit Option 5.3 -�= 1.0 credit Bradford White RE2H80T10 � i Building Envelope: Ceiling: (vaulted) R-38 Ceiling: (attics) R-49 Exterior Walls: R-21 Below -Grade Wall R-10/15/21 Int. + TB Under Slab -on -grade: R-10 Floors over Unconditioned Space: R 38 Window and Door Headers insulated min. R-10 ��- Mechanical Ventilation: New whole -house ventilation system to be installed using a Lifebreath HRV intergrated with heating ducts and control system that complies with M1505.4.1 through M1505.4.4 Exterior Doors: Doors with raised sill U-Factor= 0.20 per manufacturer. Glazing: See window schedule O �^ o,�00 a Q� V) oLd ho_ N O� M W J Ln V) RESUB Apr 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT J W IO�cc W 04 CD W co LU � � Q Z = uj OHo Cl) Z ti O LU r � G m N LU O cN ti Z N N N N N N 0 LU m co It 0 0� U 0 � 0 � 0 0- 010 N Z LU Q ~ J O a0,6Z W W �_ Q U V Al ■ 0 N N N 10 N 1 A2.1 I I F--I— --- ---I I co I REMOVE REMOVE I EXISTING I II SHED � I II LL-- I — —� —Lu IZ I� NEW CONCRETE AT EXISTING IPATIO AREA O of a O LL I d- I I Y C) - iT ui 0 o= w co I ' Y >J W H W U z O U w z i� N 5'-0" 26'-5 1 /2" REPLACE EXISTING ASPHALT 1'-6" 16'-0" W/ CONC. 42'-5 1 /2" 16'-0" 81-7 N i ® 50 CFM 0 0 NEW BATH �N 0 N w z C.4 co wo Of w �: 6'-0" NEW DOOR 5'-0" ROLL -UP INSULATEED DOOR U-VALUE = 0.08 VERIFY WITH MANUF. THAT MEETS IRC 302.5 NEW STORAGE SQ, 3'_0" NEW DOOR: 20 MIN FIRE RATED W/ SELF CLOSER AND SMOKE GASKET EGRESS WINDOW SILL HT TO BE NO MORE THAN 44" ABOVE FLOOR NEW BEDROOM 11'-7" . ITZ RM — Sb io N NEW DOOR suo NOTE: WINDOW HEAD HT IS 6'-8" 4'-0" I 16'-0" 3'-6" 0 �U® Lo o N NEW REMOVE WALL EXPANDED FAMILY ROOM NEW CONCRETE PATIO NEW EXTERIOR STAIRS �--�-- W/ (3) 2X12 PT STRINGERS 12R@7" IC 10 T @ 10" SEE HANDRAIL NOTE LOWER FLOOR 32'-4" q I UP M � N PLAN BOTTOM LANDING OF STAIRS IS AT PATIO 3'-0" N 0 .z 0 Lo CD J Q O Q O p m Q O O ~ N J � >J � 06 H w Q Q m J N z EXISTING GARAGE FURNACE NOTE: INTERCONNECT NEW CO AND SD WITH EXIST. INTERCONNECTION EXISTING BEDROOM EXISTING SMOKE DETECT WIT HEAT DETECTOR CONNECTED TO SMOKE ALARM S EXISTING STORAGE suo UP LAUNDRY EXISTING BATH EXISTING BEDROOM m �I HANDRAIL NOTE: ALL HANDRAILS SHOULD COMPLY WITH R311.7.8 HANDRAILS SHOULD BE 34" DIRECTLY ABOVE TREAD NOSE UNLESS NOTED OTHERWISE ALL HANDRAILS SHALL START AT LEAST DIRECTLY ABOVE TOP RISER, AND EXTEND TO AT LEAST THE TOP OF THE LOWEST RISER AND HANDRAIL ENDS MUST RETURN TO ADJACENT WALLS HANDRAILS TO BE CONTINOUS AT ALL STAIR FLIGHTS. ENDS OF HANDRAILS TO TERMINATE INTO WALL WITH SAFETY TERMINAL. HANDRAIL GRIP CROSS SECTION TO BE 1 1/4"-2" DIA. AND AT 1 1/2" FROM WALL AND COMPLY WITH R311.7.8.5 GUARD RAIL NOTE: ALL GUARD RAILS TO MINIMUM 36" WITH ANY OPENINGS WIDER THEN 4" BOTH GUARD RAIL AND HANDRAIL TO BE PRE MANUFACTURED BY AGS STAINLESS RAILING SYSTEMS SCALE 1/4" = 1'-0" 0 4 8 O O 1 O L 0 0 j w a m a V) oLa ho_ N O� M W J Ln cn RESUB Apr 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT J W O W O W CO W � � Q Z = to OHo i/) Lo Z ti O W r m G m N W O c4 w ti z � L N N N N O of w m O +� U 0) H w 0 a_0- U 0 a cl) W �Oa 0 J J JLa A2.1 i■ DECK CONSTRUCTION TO CONSIST OF APPROVED ■ WOODS OF NATURAL RESISTANCE TO DECAY OR I I BE TREATED WOOD AND LABELED ACCORDINGLY. ■ ■ I RC R317.1 & R317.2 I■ Hardware and fasteners in contact with ■ preservative -treated wood shall be of I ■ hot -dipped zinc galvanized steel, ■ Istainless steel, silicon bronze or copper. I In the absence of manufacturer's recommendations I■ a minimum of ASTM A 653 type G185 zinc -coated ■ galvanized steel, or equivalent, shall be used. I ■ IRC R317.3.1 IBC 2304.10.5.1 ■ N 1 \ UPPER FLOOR PLAN A2.2 AA,-nlv SCALE 1/4" = 1'-0" 0 4 8 O O I O 7 I o �^ 0 o,�00 a aM V) oLLj Lo_ [V F- O� M W 0 J Ln V) RESUB Apr 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT J 300 W U) W 04 o W co W � � Q Z=C OHo C/) Lr)Z WtiO LV r 2 c m N W O cal ti Z N L6 N N (D N N O w m O N LL 0CD a_U 0 a w0Z a�� DLLa X O O mn D r m - A CD C) 2 isk) ■ ROOF PLAN Alcorrections Project ROBERSON Permit 1.5.21 3.16.22 DRAFT 12.9.21 R 0 B E R S 0 N 7622 175TH EDMONDS, O m D REMODEL D0o M STREET SW MJ°N)C C WA 98026 ?`U) M� o NIm LGH STUDIO 5319 2ND AVE NVV SEATTLE, WA 98107 (206) 910-7438 1 A3.1 0o co N_ r 80 EXISTING COVERED PORCH i EAST ELEVATION MAX. HT ALLOWED RIDGE HEIGHT 2 A3.1 NEW CONSTRUCTION NORTH ELEVATION RIDGE HEIGHT N I. MAX. HT ALLOWED RIDGE HEIGHT SECOND FLOOR AVERAGE GRADE ELEV. 211.4' NEW BASEMENT ADDITION z O U U) z O w z SCALE 1/4" = 1'-0" 0 4 8 O O I O SCALE 1/4" = 1'-0" 0 4 8 O O I O o �^ 0 o,�00 a am V) 0 LLj [V F— O� M W o J Ln cn RESUB Apr 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT J W a cc W 04 o W co W � � Q Z = uj OHo C/) Lr)Z WtiO W r � 0 m N W O 04 o� to ti Z O w m _ N L N N +� O U U 4% O E 0 L U a Z O F- Q W J W A3ml 1 A3.2 EAST ELEVATION SCALE 1 /4" = 1'-0" 0 4 8 O O I O WINDOW SCHEDULE EGRESS AFETY GLASS LOCATION DESCRIPTION TYPE SIZE WxH - FRAME AREA SF - U-VALE NFRC ID. VGA W1 A3.1 MV ES Low E AWNING 2'-6" X 3'-0" 7.5 0.28 W2 A3.1 MV ES Low E SLIDER 5'-0" X 3'-0" 15 0.28 W3 A3.1 MV ES Low E PATIO SLIDER 6'-0" X 7'-0" 42 0.28 Si A4 MV ES Low E SLIDER 4'-0" X 3'-0" 12 0.28 SG S2 A4 MV ES Low E PICTURE 4'-0" X 3'-0" 12 0.28 SG TOTAL VGA= 88.5 x .28 = 24.78 UA DOOR D1 A3.1 OVERHEAD ROLL UP 5'-0" X 7'-0" KEY: MV ES Low E= Marvin Window Low E1 Essential (Fiberglass) EXIST. = EXISTING WINDOWS GL. BLK = GLASS BLOCK S = SOUTH W = WEST N = NORTH E = EAST EGRESS = MEETS CODE EGRESS REQ. SG = SAFETY GLASS 2 A3.2 WINDOW SCHEDULE 0 4 8 0 0 I 0 o �o o,�00 Q M Q 77 z�a' V n w r o J Ln V) RESUB Apr 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT J w V) a to OWN O woo w Q/ Z = V) OHo cf) Lc)Z WHO w�� 0 m N W O c-4 ti Z O IY w C0 O N N N — N N N U) O O cn O O U Q% 0 D- E a L U L U Z O F— Q w J w A3m2 !DECK CONSTRUCTION TO CONSIST OF APPROVED WOODS OF NATURAL RESISTANCE TO DECAY OR I IBE TREATED WOOD AND LABELED ACCORDINGLY. I RC R317.1 & R317.2 — - — - — - — - — - — - — - — - — - — I■ Hardware and fasteners in contact with ■ preservative -treated wood shall be of I ■ hot -dipped zinc galvanized steel, ■ Istainless steel, silicon bronze or copper. I In the absence of manufacturer's recommendations ■ a minimum of ASTM A 653 type G185 zinc -coated ■ I galvanized steel, or equivalent, shall be used. I ■ I RC R317.3.1 IBC 2304.10.5.1 ■ � ... - — - — - — - — - — - — - — - J MANUFACTURED RAILING SYSTEM BY AGS STAINLESS WITH CABLE INFIL. 6" S SHAPE GUTTER 2x HARDI FACIA PROVIDE SOLID BLOCKING AT GUARD RAIL POSTS HARDI SOFFIT TYP. NEW EXTERIOR WALL CONSTRUCTION: - FIBER CEMENT SIDING (VERIFY) - BLDG PAPER - 1/2" PLYWOOD SHEATHING (PER PANEL SCHEDULE) - 2X4 STUDS (2) WALLS @ 16 - R-21 BATT INSUL. (R-15 BATT + R-5 RIDGID @ - 1/2 GWB CONCRE SLAB NEW 4"F DRAIN SI GRAVEL. TO STOP DISCHAF TYP. DECK ROOF CONSTRUCTION - MEMBRANE, GLUE DOWN WATERPROOF, WALKABLE SHEET SURFACE1 -3/4" PLY SHEATHING -RAFTERS PER STRUCT -R-10 AIR -IMPERMEABLE INSULATION (SPRAY FOAM) -R-35 BATT INSULATION MIN. (DEPTH WILL VARY WITH SLOPE OF ROOF. NO AIR CAVITY BETWEEN GWB AND PLY SHEATHING) -5/8 GWB NOTE: INSTAL 2" OF R-10 AIR -IMPERMEABLE INSULATION IN DIRECT ONCTACT WITH UNDERSIDE OF ROOF SHEATHING IN ALL AREA OF UNVENTED ROOF 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --- ------ ----------------------------- 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 \ WALL SECTION A4.1 TYP. BASEMENT FLOOR CONSTRUCTION: - FIN. FLOOR - 4" CONC. PER STRUCT. - R-10 RIGID INSUL. - 6 MIL. MOISTURE BARRIER - STRUCTURAL FILL TAPER SLAB FOR THERMAL BREAK SCALE 1 /4" = 1'-0" 0 4 8 O O I O o �o o,�00 Q M Q 77 z�a' V n w r o J Ln V) RESUB Apr 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT J W 0�_co OWN 0 W oo W � � Q Z=C OHo Cf) Z W O W 2 m N W O C-4 ti Z O a' LLI m o _ N L6 V_ N N CIS U) C: O � U Q% 0 d- � E 0- U L U J_ Q H W 0 J J A4m 1 GENERAL STRUCTURAL NOTES (THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE PLANS) CRITERIA 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, THE INTERNATIONAL BUILDING CODE (2018 EDITION), & BUILDING DEPARTMENT MODIFICATIONS TO THE INTERNATIONAL BUILDING CODE. 2. DESIGN LOADING CRITERIA: FLOOR LIVE LOAD (RESIDENTIAL). . . . . . . . . . .40 PSF FLOOR LIVE LOAD (BALCONY AND DECK) . . . . . . . .60 PSF ROOF SNOW LOAD (Pf) . . . . . . . . . . . . . . . . 25 PSF 3101111 BASIC WIND SPEED (3-SECOND GUST) . . . . . . . .110 MPH WIND IMPORTANCE FACTOR (Iw). . . . . . . . . . . . .1.0 WIND EXPOSURE . . . . . . . . . . . . . . . . . . . . B TOPOGRAPHICAL FACTOR (Kzt). . . . . . . . . . . . .1.00 EARTHQUAKE: LAT. / LONG . . . . . . . . . . . . . . 47.840 /-122.337 SEISMIC IMPORTANCE FACTOR (Ie) . . . . . . . . . . .1.0 SEISMIC USE GROUP . . . . . . . . . . . . . . . . . . . I MAPPED SPECTRAL RESPONSE (Ss/Si) . . . . . . 1.31g/0.51g SPECTRAL RESPONSE COEF. (SDS/SD1). . . . . .0.87g/0.51g SEISMIC FORCE RESISTING SYSTEM:. . .PLYWOOD SHEAR WALLS DESIGN BASE SHEAR. . . . . . . 2.15k SEISMIC RESPONSE COEFICIENT (Cs) . . . . . . . . .0.160 SEISMIC DESIGN CATEGORY . . . . . . . . . . . . . . . D RESPONSE MODIFICATION FACTOR (R). . . . . . . . . . 6.5 ANALYSIS PROCEDURE . . . . . . EQUIVALENT LATERAL FORCE REFERENCE: OSHPD SEISMIC DEISGN TOOL 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CON- DITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CON- STRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST VERIFIED. CONTRACTOR SHALL DETERMINE THE LOCATION OF ALL ADJACENT UNDERGROUND UTILITIES PRIOR TO COMMENCING EXCAVATION. THE CONTRACTOR SHALL BRING ALL CONFLICTS AND DISCREPANICES TO THE ATTENTION OF THE ARCHITECT AND STRUCTURAL ENGINEER. 5. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. EXISTING REINFORCING SHALL BE RETAINED UNDAMAGED WHERE NOTED ON THE PLANS. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 PSF. ALL NEW OPENINGS THROUGH EXISTING CONCRETE OR MASONRY WALLS, SLABS AND BEAMS SHALL BE ACCOMPLISHED BY SAW CUTTING WHEREVER POSSIBLE. 6. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CON- TRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES OF THE OWNER, CON - CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. 8. SPECIAL INSPECTION OF THE FOLLOWING TYPES OF CONSTRUCTION SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS 110 AND 1704 OF THE INTERNATIONAL BUILDING CODE AND THE PROJECT SPECIFICATIONS BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE ARCHITECT, AND RETAINED BY THE BUILDING OWNER. THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING DEPARTMENT SHALL BE FURNISHED WITH COPIES OF ALL INSPECTION AND TEST RESULTS. A. STRUCTURAL STEEL FABRICATION AND ERECTION (INCLUDING FIELD WELDING AND HIGH -STRENGTH FIELD BOLTING) B. EXPANSION BOLTS AND THREADED EXPANSION INSERTS C. EPDXY GROUTED INSTALLATIONS 9. SHOP DRAWINGS FOR THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION OF THESE ITEMS. A. STRUCTURAL STEEL B. GLUED LAMINATED MEMBERS C. PLYWOOD WEB JOISTS APPROVED SETS OF ALL SHOP DRAWINGS SHALL ALSO BE SUBMITTED TO THE BUILDING DEPARTMENT. 0 i GEOTECHNICAL 10. FOUNDATION NOTES: ALLOWABLE SOIL PRESSURE AND LATERAL EARTH PRESSURE ARE ASSUMED AND THEREFORE MUST BE VERIFIED BY A QUALIFIED SOILS ENGINEER. IF SOILS ARE FOUND TO BE OTHER THAN ASSUMED, NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW ADJACENT FINISHED GRADE. UNLESS NOTED OTHERWISE, FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE. BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. ALLOWABLE SOIL PRESSURE . . . . . . . . . . 2,000 PSF LATERAL EARTH PRESSURE . . . . . . . . . . . 35 PCF CONCRETE 11. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORD- ANCE WITH IBC SECTION 1905 AND ACI 301. CONCRETE SHALL ATTAIN A 28-DAY STRENGTH OF F'C = 2,500 PSI AND MIX SHALL CONTAIN NOT LESS THAN 5-1/2 SACKS OF CEMENT PER CUBIC YARD AND SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS. THE MINIMUM AMOUNTS OF CEMENT AND MAXIMUM AMOUNTS OF WATER MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE STRUCTURAL ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CON- CRETE. THE CONCRETE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE, WATER AND ADMIXTURES AS WELL AS THE WATER CE- MENT RATIO, SLUMP, CONCRETE YIELD AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH IBC 1905.1.3. REVIEW OF MIX SUBMITTALS BY THE ENGINEER OF RECORD INDICATES ONLY THAT INFORMATION PRESENTED CONFORMS GENERALLY WITH CONTRACT DOCUMENTS. CONTRACTOR OR SUPPLIER MAINTAINS FULL RESPONSIBILITY FOR SPECIFIED PERFORMANCE. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR - ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO ASTM C260, C494, AND C618. TOTAL AIR CONTENT SHALL BE IN ACCORDANCE WITH TABLE 19.3.2.1 OF THE ACI 318. 12. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 60, FY = 60,000 PSI. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. 13. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORD- ANCE WITH ACI 318. LAP ALL CONTINUOUS REINFORCEMENT 40 BAR DIAMETERS OR 2'-0" MINIMUM. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTER- SECTIONS. LAP CORNER BARS 40 BAR DIAMETERS OR 2'-0" MINIMUM. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. 14. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: A. FOOTINGS AND OTHER UNFORMED SURFACES, EARTH FACE . . .3" B. ALL OTHER SURFACES . . . . . . . . . . . . . . . . 1 1/2" ANCHORAGE 15. EXPANSION BOLTS INTO CONCRETE AND GROUTED MASONRY UNITS SHALL BE "STRONG -BOLT" ANCHORS AS MANUFACTURED BY THE SIMPSON COMPANY AND INSTALLED IN STRICT ACCORDANCE WITH ICC ESR 1771, INCLUDING MINIMUM EMBEDMENT REQUIREMENTS. 16. EPDXY -GROUTED ITEMS SPECIFIED ON THE DRAWINGS SHALL BE GROUTED WITH "SET-XP" HIGH STRENGTH EPDXY AS MANUFACTURED BY THE SIMPSON COMPANY AND INSTALLED IN STRICT ACCORDANCE WITH ICC ESR 2508. 17. TITEN HD ANCHORS SPECIFIED ON THE DRAWINGS SHALL CONSIST OF "TITEN HD" HEAVY DUTY SCREW ANCHORS AS MANUFACTURED BY THE SIMPSON COMPANY AND INSTALLED IN STRICT ACCORDANCE WITH ICC ESR 2713. STEEL 18. STRUCTURAL STEEL DESIGN, FABRICATION, AND ERECTION SHALL BE BASED ON THE LATEST EDITIONS OF THE RISC SPECIFICATIONS AND CODES: A. SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (RISC 360) B. CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES (RISC 303) C. SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS. BOLTS IN SHEAR OR BEARING TYPE CONNECTIONS NEED ONLY BE TIGHTENED TO THE SNUG TIGHT CONDITION PER SECTION 8(C). 19. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING MINIMUM STANDARDS. PLATES, ANGLES, AND CHANNELS SHALL CONFORM TO ASTM A36, FY = 36 KSI. WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992, FY = 50 KSI. STEEL PIPE SHALL CONFORM TO ASTM A53, TYPE E OR S, GRADE B, FY = 35 KSI. SQUARE OR RECTANGULAR STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE B, FY = 46 KSI. ANCHOR BOLTS AND CONNECTION BOLTS SHALL CONFORM TO ASTM A307. THREADED ROD AND STUDS SHALL CONFORM TO ASTM A36. 20. ALL WELDING SHALL BE IN CONFORMANCE WITH AISC AND AWS STANDARDS AND SHALL BE PERFORMED BY WABO CERTIFIED WELDERS USING E70XX ELECTRODES. ONLY PREQUALIFIED WELDS (AS DEFINED BY AWS) SHALL BE USED. WOOD 21. FRAMING LUMBER SHALL BE KILN DRIED OR MC-15, AND GRADED AND MARKED IN CON- FORMANCE WITH WCLIB STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17, LATEST EDITION. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS: (2X MEMBERS) HEM -FIR NO. 2 MINIMUM BASE VALUE, FB = 850 PSI (3X & 4X MEMBERS) DOUGLAS FIR NO. 1 MINIMUM BASE VALUE, FB = 1000 PSI STRUCTURAL LIGHT FRAMING: DOUGLAS FIR NO. 2 (INCL. 3X AND 4X POSTS) MINIMUM BASE VALUE, FB = 900 PSI BEAMS AND STRINGERS: DOUGLAS FIR NO. 1 (INCL. 6X AND LARGER) MINIMUM BASE VALUE, FB = 1350 PSI POSTS AND TIMBERS: DOUGLAS FIR NO. 1 (6X6 AND LARGER ) MINIMUM BASE VALUE, FC = 1000 PSI STUDS, PLATES & MISC. FRAMING: DOUGLAS FIR OR HEM -FIR STANDARD GRADE 2X6 STUDS AND PLATES: HEM -FIR NO.3/ STUD GRADE 2X AND 3X T & G DECKING HEM -FIR COMMERICAL DEX, MINIMUM BASE VALUE, FB = 1350 PSI 22. GLUED LAMINATED MEMBERS SHALL BE FABRICATED IN CONFORMANCE WITH ASTM AND AITC STANDARDS. EACH MEMBER SHALL BEAR AN AITC IDENTIFICATION MARK AND SHALL BE ACCOMPANIED BY AN AITC CERTIFICATE OF CONFORMANCE. ALL SIMPLE SPAN AND CANTILEVERED BEAMS SHALL BE ALASKA YELLOW CEDAR COMBINATION 20E-V12, FB = 2,000 PSI, FV = 265 PSI. CAMBER ALL SIMPLE SPAN GLULAM BEAMS TO 3,500' RADIUS, UNLESS SHOWN OTHERWISE ON THE PLANS. 23. ENGINEERED LUMBER MEMBERS SHALL BE MANUFACTURED UNDER A PROCESS BY THE NATIONAL RESEARCH BOARD. EACH PIECE SHALL BEAR A STAMP OR STAMPS NOTING THE NAME AND PLANT NUMBER OF THE MANUFACTURER, THE GRADE, THE NATIONAL RESEARCH BOARD NUMBER, AND THE QUALITY CONTROL AGENCY. ALL LUMBER SHALL BE MANUFACTURED IN ACCORDANCE WITH THE APPROPRIATE NER REPORT AND GLUED WITH A WATERPROOF ADHESIVE MEETING THE REQUIREMENTS OF ASTM D2559 WITH ALL GRAIN PARALLEL WITH THE LENGTH OF THE MEMBER. PSL FB = 2900 PSI E = 2000 KSI FV = 290 PSI NER-292 LSL FB = 2250 PSI E = 1500 KSI FV = 285 PSI NER-481 LVL FB = 2600 PSI E = 1800 KSI FV = 285 PSI NER-126 DESIGN SHOWN ON PLANS IS BASED ON LUMBER MANUFACTURED BY THE WEYERHAUSER CORPORATION. ALTERNATE MANUFACTURERS MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND STRUCTURAL ENGINEER. ALTERNATE JOIST HANGERS AND OTHER HARDWARE MAY BE SUBSTITUTED FOR ITEMS SHOWN PROVIDED THEY HAVE ICC APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. ALL JOIST HANGERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH MEMBERS PROVIDED. ALL PROPOSED HOLE SIZES AND LOCATIONS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR APPROVAL TWO WORKING DAYS PRIOR TO DRILLING HOLES. 24. PREFABRICATED PLYWOOD WEB JOIST DESIGN SHOWN ON PLANS IS BASED ON JOISTS MANUFACTURED BY THE WEYERHAUSER CORPORATION AND SHALL BE FURNISHED AND INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S PUBLISHED SPECIFICATIONS. ALL NECESSARY BRIDGING, BLOCKING, BLOCKING PANELS, STIFFENERS, ETC., SHALL BE DETAILED AND FURNISHED BY THE MANUFACTURER. SUBMIT SHOP DRAWINGS TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION. ALTERNATE PLYWOOD WEB JOIST MANUFACTURERS MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND STRUCTURAL ENGINEER. ALTERNATE JOIST HANGERS AND OTHER HARDWARE MAY BE SUBSTITUTED FOR ITEMS SHOWN PROVIDED THEY HAVE ICC APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. ALL JOIST HANGERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH PLYWOOD WEB JOIST PROVIDED. ALL HOLES SHALL CONFORM TO THE MANUFACTURERS SPECIFICATIONS. IF THREE OR FEWER HOLES ARE PROPOSED FOR A SINGLE JOIST, HOLES SHALL CONFORM TO THE WEYERHAUSER ILEVEL TJI ALLOWABLE HOLE CHART. IF MORE THEN THREE HOLES ARE PROPOSED FOR ONE SINGLE JOIST, ALL HOLE SIZES AND LOCATIONS SHALL BE SUB- MITTED TO THE STRUCTURAL ENGINEER FOR APPROVAL TWO WORKING DAYS PRIOR TO DRILLING HOLES. 25. PLYWOOD SHEATHING SHALL BE GRADE C-D, EXTERIOR GLUE OR STRUCTURAL II, EXTERIOR GLUE IN CONFORMANCE WITH APA STANDARDS. ORIENTED STRAND BOARD OF EQUIVALENT THICKNESS, EXPOSURE RATING AND SPAN RATING MAY BE USED IN LIEU OF PLYWOOD. A. ROOF SHEATHING SHALL BE 1/2" (NOM.) WITH SPAN RATING 24/0. B. FLOOR SHEATHING SHALL BE 3/4" (NOM.) WITH SPAN RATING 40/20. C. WALL SHEATHING SHALL BE 1/2" (NOM.) WITH SPAN RATING 24/0. REFER TO WOOD FRAMING NOTES BELOW FOR TYPICAL NAILING. 26. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE - TREATED WITH AN APPROVED PRESERVATIVE OR (2) LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER SHALL BE PROVIDED BETWEEN UNTREATED WOOD AND CONCRETE OR MASONRY. ALL WOOD EXPOSED TO WEATHER WITHOUT THE ADEQUATE PROTECTION OF A ROOF OR EAVE SHALL BE AN APPROVED WOOD OF NATURAL RESISTANCE TO DECAY OR PRESSURE TREATED. SUCH MEMBERS INCLUDE HORIZONTAL MEMBERS SUCH AS GIRDERS, JOISTS, AND DECKING; OR VERTICAL MEMBERS SUCH AS POSTS, POLES, AND COLUMNS. 27. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR MOST RECENT CATALOG. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS OR BOLTS IN EACH MEMBER. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. UN- LESS NOTED OTHERWISE, ALL NAILS SHALL BE COMMON. ALL SHIMS SHALL BE SEA- SONED AND DRIED AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. HANGERS IN DIRECT CONTACT WITH PRESERVATIVE -TREATED WOOD SHALL BE EITHER STAINLESS STEEL (SST300), POST HOT -DIPPED GALVANIZED(HDG) OR GALVANIZED WITH A MINI- MUM OF 1.850Z ZINC PER SQUARE INCH (ZMAX). UNLESS NOTED OTHERWISE, ALL LUMBER JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "LUS" SERIES JOIST HANGERS, AND ALL TJI JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "ITT" OR " I UT" SERIES JOIST HANGERS. 28. NAILS - NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: SIZE LENGTH DIAMETER 6D 2" 0. 113" 8D 2-1/2" 0. 131" 10D 3" 0. 148" 12D 3-1/4" 0. 148" 16D 3-1/2" 0. 162" IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION) FOR REVIEW AND APPROVAL. NAILS SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED. 29. WOOD FRAMING NOTES --THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN: A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE. MINIMUM NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO TABLE 2304.10.1 OF THE INTERNATIONAL BUILDING CODE. UNLESS NOTED OTHERWISE, ALL NAILS SHALL BE COMMON. COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. B. WALL FRAMING: ALL STUD WALLS SHOWN AND NOT OTHERWISE NOTED SHALL BE 2X4 STUDS @ 16" O.C. AT INTERIOR WALLS AND 2X6 @ 16" O.C. AT EXTERIOR WALLS. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS. TWO 2X8 HEADERS SHALL BE PROVIDED OVER ALL OPENINGS NOT OTHERWISE NOTED. SOLID BLOCKING FOR WOOD COL- UMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE TO EACH STUD WITH TWO 16D NAILS, AND TOENAIL OR END NAIL EACH STUD TO BOTTOM PLATE WITH TWO 16D NAILS. FACE NAIL DOUBLE TOP PLATE WITH 16D AT 12" O.C. AND LAP MINIMUM 4'-0" AT JOINTS AND PROVIDE SIX 16D NAILS AT 4" O.C. EACH SIDE OF JOINT. ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16D NAILS AT 12" O.C. STAGGERED OR BOLTED TO CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS (WITH 7" MINIMUM EMBEDMENT) @ 4'-0" O.C. UNLESS INDICATED OTHERWISE. INDIVI- DUAL MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH 16D @ 12" O.C. STAGGERED. REFER TO THE PLANS AND SHEAR WALL SCHEDULE FOR REQUIRED SHEATHING AND NAILING. WHEN NOT OTHERWISE NOTED, PROVIDE GYPSUM WALLBOARD ON INTERIOR SURFACES NAILED TO ALL STUDS, TOP AND BOTTOM PLATES AND BLOCKING WITH NAILS AT 7" O.C. USE 5D COOLER NAILS FOR 1/2" GWB AND 6D COOLER NAILS FOR 5/8" GWB. WHEN NOT OTHERWISE NOTED, PROVIDE 1/2" (NOM.) APA RATED SHEATHING (SPAN RATING 24/0) ON EXTERIOR SURFACES NAILED AT ALL PANEL EDGES (BLOCK UNSUPPORTED EDGES), TOP AND BOTTOM PLATES WITH 8D @ 6" O.C. AND TO ALL INTERMEDIATE STUDS AND BLOCKING WITH 8D @ 12" O.C. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS. C. FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS AROUND ALL OPENINGS IN FLOORS OR ROOFS UNLESS OTHERWISE NOTED. PROVIDE SOLID BLOCKING AT ALL BEARING POINTS. TOENAIL JOISTS TO SUPPORTS WITH TWO 16D NAILS. ATTACH TIMBER JOISTS TO FLUSH HEADERS OR BEAMS WITH METAL JOIST HANGERS IN ACCORDANCE WITH TIMBER CONNECTOR NOTE. NAIL ALL MULTI -JOIST BEAMS TO- GETHER WITH 16D @ 12" O.C. STAGGERED. UNLESS OTHERWISE NOTED ON THE PLANS, ROOF AND FLOOR SHEATHING SHALL BE LAID UP WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS AND NAILED WITH 8D NAILS @ 6" O.C. TO FRAMED PANEL EDGES AND OVER STUD WALLS AS SHOWN ON PLANS AND @ 12" O.C. TO INTERMEDIATE SUPPORTS. PROVIDE APPROVED PLYWOOD EDGE CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES SHALL HAVE APPROVED TONGUE -AND -GROOVE JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF ALL ROOF AND FLOOR SHEATHING. TOENAIL BLOCKING TO SUPPORTS WITH 16D @ 12" O.C. UNLESS OTHERWISE NOTED. AT BLOCKED FLOOR AND ROOF DIAPHRAGMS PROVIDE FLAT 2X BLOCKING AT ALL UNFRAMED PLYWOOD PANEL EDGES AND NAIL WITH EDGE NAILING SPECIFIED. Harriott Valentine Engineers Inc. 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206 624 4760 fax 206 447 6971 www.harriottvalentine.com RESUB Apr 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 3/16/22 Project Contact Kevin Tsuchida tel 206 624 4760 ex. 22 fax 206 447 6971 ksuchida@harriottvalentine.com Project Architect LGH Studio 515 Stewart St, Suite 515 Seattle. WA 98101 Project Roberson Remodel 7622 175th St SW Edmonds, WA 98026 Issue Date Issue Description 01/05/2021 Permit Set 03/16/2022 Corrections Set 10 Building Department Approval Drawing Title GENERALSTRUCTURAL NOTES Drawing Number S 1 0 J w 0 2 w z O co 00 TYPICAL 4" THICK SLAB REINF. W/ W2.942.9 6x6 W.W.M. CTR'D. RIGID INSUL. PER ARCH'L. —x x x x x x— SHEARWALL PER PLAN —' 24" SQ PAD 3 FOOTING ,ZO`��' S2.0 PER 5/S2.0 24" SQ PAD - FOOTING ,ZO`�� PER 5/S2.0 - 24" SQ PAD FOOTING PER 5/S2. HV Harriott Valentine Engineers Inc. 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206 624 4760 fax 206 447 6971 SLAB- - - - - - - - - 6 MIL VAPOR BARRIER °° ° o°°°OOo°�° °° 000 °Oo°� 8° °� °oa8° ooa° °oa8�`------------ ���\��\��\��\\�\��\��\\�\��\��\\� 4" FREE -DRAINING #4 @ 16"oc VERT. (CENTERED) r ISEE ________ - , ti-------- -- NOTE 1 _ ________ - - - - - - - - - - - - - - - - - - --------- www.harrlottvalentlne.com GRANULAR FILL 26 P.T. PLATE WITH #4 @ 10"oc HORIZ. -; 5/8" 0 ANCHOR BOLTS PER [(2) AT TOP OF WALL] l CONTROL JOINT FORMER SW SCHEDULE (@ 48'oc CONTROL JOINT CONSTR. JOINT —x x x% °x x x— "ZIP STRIP" 11/2" DEEP o 0000- - (JOINT MAY BE SAW -CUT °�'°°°�°OO°°AT CONTRACTOR'S OPTION )fye. a8�a °a8 ) CUT ALT. WIRES AT JOINT 2nd POUR 1st POUR -- PLASTIC JOINT KEY "MEADOW BURKE" —x x x x x x— STOP REINF. 1" CLEAR OF o0 - o�000°°oQ o 0o°g-o°o0°00Q� JOINT EACH SIDE 8 °°o° °°O08 °°o ° °°O08 ° ELSEWHERE) SLAB -ON -GRADE Z II PER 2/S2.0 % /, /'//\\/�/�\\/�\\/// x x x x x x x ° °Oo°� °� g� o° 1 °ao °°° / / /r % ° ° o°� (2) #4 CONT. = j `L - I I _ J 1 24 SQ PAD FOOTING PER 4/S2.0 - L — -1 RES U 6 Apr 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT �\��\��\��\�X \�/\��\�� DRAINAGE PER I 1 ARCHITECTURAL 5" 6" 5" - l SLAB —ON —GRADE (INSULATED) I l 3 /4" - 1 ' - 0" 2 3/4" = 1 ' — 0" 3 I I I SLAB —ON —GRADE I _ I PER 2/S2.0 F_ (PLAN VIEW) I 1 I I 1 F--1 1_ l I l r,J - -------------------------------------------I ----------------- --------------------------_------ �;; F---------------- F- -- COLUMN PER PLAN 12"0 PLINTH, REINF. WITH COLUMN PER PLAN ------------------------------------------------------J 24" SQ PAD �L — ���t I POERTING 4/S2.0 1 I l (6) #4 VERT. AND TIES (PRESSURE -TREATED) I I l 3) #4 EACH WAY BOTTOM ABA SERIES POST BAS SLAB -ON -GRADE #3 X @ 3"oc ABA SERIES POST BASE 3 I 2.o j l I I l i �L,: L Ilk � F • w PER 2/S2.0 (3) #4 EACH WAY 1 BOTTOM -� I I I - I I I SEE NOTE 1 I I I i i 39:,-; � ��n. tip' 3/16/22 x x x x x x x x x x x x x x °o O° p°o °0 o8�o° o � Z c0 Project Contact Kevin Tsuchida tel 206 624 4760 ex. 22 fax 206 447 6971 ktsuchlda@harnottvalenUne.com DIMENSION PER PLAN DIMENSION PER PLAN L_ — — — — O& — — — — — — — — — — — — I " I`JI 1 Project Architect LGH Studio 515 Stewart St, Suite 515 Seattle, WA 98101 3/4" = 1'-0" 4 3/4" = 1'-0" S20 Project Roberson Remodel 24" SQ PAD J 7622 175th St SW Edmonds, WA 98026 FOOTING 1 FOUNDATION 52.0 scale: 1/4" = 1'-0" PER 5/S2.0 PLAN _ I I I I I I I Issue Date Issue Description 01/05/2021 Permit Set 03/16/2022 Corrections Set 1Q I I I I I I I I Building Department Approval FOUNDATION PLAN NOTES 1. WHERE NEW CONCRETE WALLS OR FOOTING ABUT EX. CONCRETE, PROVIDE DOWELS #4 x 2'-0" TO MATCH HORIZ. REINFORCING, EMBED 5" IN EPDXY GROUT. LEGEND 2. SEE 9/S3.0 FOR TYPICAL HOLDOWN REQUIREMENTS AT CONCRETE WALLS AND SPAN FOOTINGS. ❑ COLUMN BELOW � > EXTENT X SX. SECTION DETAIL NEW STRUCTURAL WALL EXISTING STRUCTURAL WALL Drawing Title FOUNDATION PLAN NEW CONCRETE WALL (FB) FLUSH BEAM NOTEH EXISTING FRAMING MEMBERS AS INDICATED ON THIS PLAN ARE Drawing Number EXISTING CONCRETE WALL ASSUMED FOR DESIGN PURPOSES ONLY. HARRIOTT VALENTINE ENGINEERS (PT) PRESSURE —TREATED SHALL NOT BE HELD LIABLE FOR LOCATION/ SIZE OF EXISTING MEMBERS — 3/4" 1'-0" 6 - — 3/4" 1'-0" - COLUMN ABOVE y�� ALL —THREAD HOLDOWN AT AS CALLED ON THIS PLAN. EXISTING MEMBERS SHALL BE VERIFIED AND END OF SHEARWALL ABOVE REPORTED TO STRUCTURAL ENGINEER OF RECORD PRIOR TO CONSTRUCTION. SZO J W 0 O 2 w Z O CO w m 01 ■L EX. WALL PER PLAN FLOOR SHEATHING NAILING PER PLAN TAPERED SLEEPERS — (SLOPE PER ARCH'L.) RC CLIPS TJI PER PLAN w/ HANGER PER SCHEDULE 13/4" LVL LEDGER w/ 3/4"0 THRU-BOLTS TOP AND BOTTOM @ Coc SHEARWALL PER PLAN - EX. RIM A35 PER SW SCHEDULE EX. JOISTS PER PLAN 3/4" = 1'-0" ° — — — — — — -FL CR- SHEATH ING — ° — — — — — — -RAILING PER PLAN — A3 PER SW SCHEDULE GUARDRAIL AND DECK ° — — — — — — _T ERED SLEEPERS — ATTACHMENT PER ° — — — — — (S P€ PER ARCH'L MANUFACTURER ° Mil -7 TJI's PER PLAN BLOCK w/ 11/4" LSL RIM BOARD SHEARWALL PER PLAN 2 EX. WALL PER PLAN TJI PER PLAN w/ HANGER PER SCHEDULE BLOCK WEB BOTH SIDES AND ATTACH w/ 3/4" 0 THRU-BOLTS TOP AND BOTTOM @ Coc FLOOR SHEATHING NAILING NAILING PER PLAN PROVIDE CONTINUOUS LSL 11/4" OVER SW RC CLIPS PLATE NAILING PER SHEARWALL SCHEDULE FLOOR SHEATHING NAILING PER PLAN EX. JOISTS PER PLAN HANGER PER SCHEDULE WF PER PLAN w/ 2x NAILER ABOVE ATTACHED w/ 3/4" 0 THRU-BOLTS @ 32"oc 3/4" = 1'-0" (3) 10d BOX EACH SIDE OF BLOCKING TJI's PER PLAN 4 GL 51/8x15 20E—V12 ` S2. Q SW1 (2)2x8 +KAG�ti V` X J N Cl- PROVIDE CMST14 ----,, FROM BEAM TO TOP PLATE BOTH SIDES OF WF BEAM 117/8" TJI 110 @ 12"oc r 3 CD Q X N TJI's PER PLAN (BEAR 13/4" MIN.) A35 PER SW SCHEDULE -10d BOX EACH SIDE OF TJI TO PLATE - 10d BOX EACH SIDEJ BLOCK ONE BAY FULL LVL 13 4x117 8 FB DRIVE NAILS 11/2" MIN. OF TJI TO PLATE -DEPTH @ 48"oc w/ - o �0 co FROM END OF TJI LSL 11/4" RIMBOARD D SHEARWALL PER PLAN - FIT TIGHT TO TJI's SW2 3/4" 1 ' — 0" 3 /4" 1 ' — 0" LSL 11/4x117/8 (STRUCTURAL FASCIA) 117/8" = 4 = � 4 TJI 110 S2.T @ 16"oc !DECK CONSTRUCTION TO CONSIST OF APPROVED WOODS OF NATURAL RESISTANCE TO DECAY OR I I BE TREATED WOOD AND LABELED ACCORDINGLY. 1 RC R317.1 & R317.2 Hardware and fasteners in contact with I preservative -treated wood shall be of I ■ hot -dipped zinc galvanized steel, ■ Istainless steel, silicon bronze or copper. I In the absence of manufacturer's recommendations a minimum of ASTM A 653 type G185 zinc -coated I galvanized steel, or equivalent, shall be used. I ■ IRC R317.3.1 IBC 2304.10.5.1 ■ . - ... - ... - ... - .... J 3/4" = 1'-0" WF BEAM PER PLAN r 3/16 SIDE PLATES 3/16% 21/2" w/ (2) 5/8"0 THRU-BOLTS WOOD COLUMN PER PLAN WF BEAM BEARING ON WOOD COLUMN 6 3/4" = 1'-0" 7 MAIN FLOOR FRAMING PLAN 1 BASEMENT WALLS S2.1 scale: 1/4" = 1'-0" FRAMING PLAN NOTES 1. SW__ INDICATES SHEARWALL TYPE PER SCHEDULE 8/S3.0. REFER TO DETAILS FOR TYPICAL SHEARWALL CONSTRUCTION. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL WALL INFORMATION. 2. REFER TO GENERAL STRUCTURAL NOTES FOR FLOOR OR ROOF SHEATHING TYPE, THICKNESS, AND NAILING. 3. COLUMNS SHALL BE DOUBLE STUD MINIMUM, UNLESS NOTED OTHERWISE. SEE 11/S3.0. 4. AT ALL SHEARWALLS PROVIDE DOUBLE TOP PLATES AND SPLICE PER 12/S3.0. 5. CSINDICATES COILED STRAP TYPE PER SCHEDULE 10/S3.0. REFER TO DETAILS FOR TYPICAL STRAP ASSEMBLY. I LSL 114x117 8 GL 5�/8x15 2OF— O U o C.0 ® 411�� EX. 2x10 @ 16"oc EX. 2x10 I @ 16"oc ` LJ -------- Al ---------' Harriott Valentine Engineers Inc. 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206 624 4760 fax 206 447 6971 www.harriottvalentine.com RESUB Apr 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 3/16/22 Project Contact Kevin Tsuchida tel 206 624 4760 ex. 22 fax 206 447 6971 ksuchida@harriottvalentine.com Project Architect LGH Studio 515 Stewart St, Suite 515 Seattle, WA 98101 Project Roberson Remodel 7622 175th St SW Edmonds, WA 98026 Issue Date Issue Description 01/05/2021 Permit Set 03/16/2022 Corrections Set 1Q Building Department Approval LEGEND HANGER SCHEDULE SPAN MEMBER HANGER FACE NAILING CAPACITY ❑ COLUMN BELOW (FLAT ONLY) (Cd = 1.0) e > EXTENT NEW STRUCTURAL WALL 117/$" TJI 110 HU11 16d COMMON 2820 lb Drawing Title X 2x10 LUS28 10d COMMON 945 lb MAIN FLOOR SX. SECTION DETAIL EXISTING STRUCTURAL WALL FRAMING PLAN NEW CONCRETE WALL (FB) FLUSH BEAM NOTEH EXISTING FRAMING MEMBERS AS INDICATED ON THIS PLAN ARE EXISTING CONCRETE WALL ASSUMED FOR DESIGN PURPOSES ONLY. HARRIOTT VALENTINE ENGINEERS Drawing Number (PT) PRESSURE —TREATED SHALL NOT BE HELD LIABLE FOR LOCATION/ SIZE OF EXISTING MEMBERS COLUMN ABOVE � ALL—THRIFIED END OFSHEARWALLOW N AT ARWALLABOVE AS CALLED N AND REPORTED TOSTRUCTU AL ENGINEER OFTHIS PLAN. EXISTING MRECORD BERS HPRIOR ALL ETOECONSTRUCTION. S2m 1 J w 0 w Z O C0 w m ■ TA SHEARWALL PER PLAN (2) STUDS MIN. — REFER TO PLAN FOR LOCATIONS WHERE BUILT—UP POST CONSISTS OF MORE STUDS HOLDOWN PER PLAN W/ SCREWS PER MFR. SPECS. (OR NAILS SIMILAR) CONCRETE STEMWALL PER PLAN (6" MIN. THICKNESS) ----------------- ----------------- J_______+________1_________________L_________________L--------- ----; ---- --- ------ -------------- PROVIDE ALL —THREAD AND --it------ ----- ------ - HEX NUT OR HEADED BOLT II AND EMBED PER SCHEDULE II II NOTE: PROVIDE 5" END DISTANCE MIN. 0 W mcD Z W J AND CENTER ON STEMWALL WIDTH HOLDOWN CAST INTO FOOTING SHEARWALL PER PLAN Ixl II II II Ixl IL a AT EX. CONC. WALL PROVIDE ALL —THREAD AND EMBED IN EPDXY GROUT PER SCHEDULE a d II d a °a II o� m� W w NOTE: PROVIDE 5" END DISTANCE MIN. AND CENTER ON STEMWALL WIDTH (2) STUDS MIN. — REFER TO PLAN FOR LOCATIONS WHERE BUILT—UP POST CONSISTS OF MORE STUDS HOLDOWN PER PLAN W/ SCREWS PER MFR. SPECS. (OR NAILS SIMILAR) CONCRETE STEMWALL PER PLAN (6" MIN. THICKNESS) HOLDOWN EMBEDDED IN EPDXY GROUT HOLDOWN SCHEDULE (NOT ALL USED ON PLANS) MARK FASTENERS TO STUDS' ANCHOR DIA.2 EMBEDMENT LENGTH SSTBS EPDXY' CAST—IN4 LTT19 (8) 10d x 3" NAILS 5/8" N/A N/A SSTB16 LTT20B (10) 10d x 3" NAILS 5/8" N/A N/A SSTB16 HDU2 (6) 1/4"0 x 21/2" SCREWS 5/8" loll N/A SSTB16 HDU4 (10) 1/4" 0 x 21/2" SCREWS 5/8" N/A 4" SSTB20 HDU5 (14) 1/4" 0 x 21/2" SCREWS 5/8" N/A N/A SSTB24 HDU8 (20) 1/4" 0 x 21/2" SCREWS 7/8" N/A N/A SSTB28 1. 10d AND 12d DIAMETER = 0.148"; 16d DIAMETER = 0.162". SCREWS SHALL BE SIMPSON "SDS" TYPE SCREWS, INSTALL PER SIMPSON RECOMMENDATIONS. 2. PROVIDE A36 OR A307 ALL —THREAD AT EPDXY AND CAST —IN ANCHORS. 3. PROVIDE SIMPSON "SET—XP" EPDXY PER GENERAL STRUCTURAL NOTES. SPECIAL INSPECTION IS REQUIRED. 4. AT CAST —IN ANCHORS PROVIDE HEAVY HEX NUT AT BOTTOM OF ALL —THREAD. HOOKED J—BOLT MAY BE USED FOR LTT HOLDOWNS. 5. AT 3x SILL PLATES, PROVIDE LONGER SSTBL MODELS. 3/4" = 1'-0" 60; SHEATHING PER SW SCHEDULE ONE-SIDED Fo-1 SHEARWALL SHEATHING PER SW SCHEDULE TWO-SIDED Oo STAGGER ANCHORS SHEARWALL AT TWO—SIDED SHEARWALLS x Q ANCHOR BOLT WITH PLATE SHEATHING PER SW WASHER PER SW SCHEDULE SCHEDULE (0.229% 3" SQUARE) TYPICAL SHEARWALL ANCHOR BOLT PLACEMENT 1-1/2" = 1 ' — 0" 2 SHEARWALL SCHEDULE (NOT ALL USED ON PLANS) MARK SHEATHING' STUDS AT ABUTTING PANEL EDGES2 PANEL EDGE NAILING3,4 RIM JOIST OR BLOCKING TO TOP PLATE BOTTOM PLATE ATTACHMENT SOLID RIM TJI RIM BOTTOM PLATE TO ANCHOR BOLT RIM JOIST BELOW' TO CONCRETES SILL PLATE AT FOUND. SW1 15/32" CDX PLYWOOD 2x 8d @ Coc A35 @ 24"oc 16d @ Coc 16d @ Coc 5/8" 0 @ 48"oc 2x SW2 15/32" CDX PLYWOOD 2x 8d @ 4"oc A35 @ 15"oc 16d @ 4"oc 16d @ 4"oc 5/8" 0 @ 32"oc 2x SW3 15/32" CDX PLYWOOD 3x 8d @ 3"oc A35 @ 12"oc N/A — USE SOLID RIM 16d @ 3"oc 5/8" 0 @ 16"oc 2x SW4 15/32" CDX PLYWOOD 3x 8d @ 2"oc A35 @ Toc N/A — USE SOLID RIM 16d @ 2"oc 5/8" 0 @ 12"oc 2x SW5 15/32" CDX PLYWOOD BOTH SIDES 3x 8d @ 3"oc A35 @ Coc N/A — USE SOLID RIM (2) ROWS 16d @ 3"oc 5/8" 0 @ 12"oc 3x SW6 15/32" CDX PLYWOOD BOTH SIDES 3x 8d @ 2"oc A35 @ 41/2"oc N/A — USE SOLID RIM (2) ROWS 16d @ 2"oc 5/8" 0 @ 12"oc 3x 1. WALL SHEATHING SHALL CONSIST OF APA RATED PLYWOOD WITH SPAN RATING 24/0. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF PANELS. 7/16" APA RATED SHEATHING (OSB) MAY BE USED IN PLACE OF 15/32" CDX. 2. STUDS AT ABUTTING PANEL EDGES MAY CONSIST OF (2)2x STUDS IN PLACE OF 3x STUDS — NAIL (2)2x STUDS TOGETHER WITH BOTTOM PLATE ATTACHMENT NAILING. 3. BLOCK ALL PANEL EDGES W/ 2x4 FLAT, ATTACH W/ PANEL EDGE NAILING. TWO STUDS MINIMUM ARE REQUIRED AT EACH END OF ALL SHEARWALLS. END STUDS SHALL RECEIVE PANEL EDGE NAILING. INTERMEDIATE STUDS SHALL BE 2x STUDS. NAIL SHEATHING TO INTERMEDIATE FRAMING MEMBERS WITH 8d @ 12"oc. 4. 8d NAILS SHALL BE 0.131" DIAMETER x 21/2" (COMMON). 16d NAILS SHALL BE 0.135" DIAMETER x 31/2" (BOX). 5. ANCHORS TO CONCRETE SHALL CONSIST OF CAST —IN —PLACE ANCHOR BOLTS, EXPANSION BOLTS, EPDXY GROUTED ALL —THREADS, OR TITEN HD HEAVY DUTY SCREW ANCHORS. CAST —IN —PLACE ANCHOR BOLTS HAVE A 7" EMBED AND SHALL BE J—BOLTS OR SHALL HAVE A HEX NUT AT THE BOTTOM END. EXPANSION BOLTS SHALL HAVE 5" EMBED AND SHALL NOT BE USED AT STEM WALL LOCATIONS WITH EDGE DISTANCE LESS THAN 5" (INSTEAD, USE EPDXY GROUTED ALL —THREADS OR TITEN HD ANCHORS). EPDXY GROUTED ANCHORS SHALL HAVE 5" EMBED AND 21/2" MIN. EDGE DISTANCE. TITEN HD ANCHORS SHALL HAVE 31/2" EMBED AND 13/4" MIN. EDGE DISTANCE. AT ALL ANCHOR BOLTS, PROVIDE STEEL PLATE WASHERS THAT ARE A MINIMUM OF 0.229" (3 GAUGE) x 3"x 3" (SIMPSON BP5/8-3 OR SIMILAR). PLACE BOLTS PER ANCHOR BOLT PLACEMENT DETAIL. Harriott Valentine Engineers Inc. 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206 624 4760 fax 206 447 6971 www.harriottvalentine.com RESUB Apr 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEARWALL PER PLAN PANEL EDGE NAILING PER SW SCHEDULE BLOCKING (OR JOIST) PER FLOOR AND ROOF DETAILS BOTTOM PLATE NAILING PER SW SCHEDULE — SHEARWALL PER PLAN II II II � II.• W o PROVIDE HALF OF SPECIFIED NAILING TO MATCH -- -- NAILING TO MATCH JOISTS PER PLAN W NAILS IN EACH END LENGTH BOTTOM PLATE NAILING BOTTOM PLATE NAILING (DIR. VARIES) I I __1L _ I I T I I _U I I•• L � , PER SW SCHEDULE PER SW SCHEDULE �,� �� V.ALt �. o Q O� *A,' PANEL EDGE NAILING FULL DEPTH BLOCKING TOP PLATE CONNECTION II II II 1I II II SHEARWALL PER PLAN PER SW SCHEDULE (OR RIM AT EXTERIOR) PER SW SCHEDULE % ____ ---F7 _ TIF ___ --n _ —_T7-- PANEL EDGE NAILING 379='.� TT SHEARWALL PER PLAN NAILING TO MATCH BLOCK ALL PANEL EDGES PER SW SCHEDULE s'kxvAL Z o A PIROVIDE 15/8" MIN. END BOTTOM PLATE NAILING 3/16/22 Z DISTANCE FOR NAILS PER SW SCHEDULE ANCHOR BOLTS & WASHERS SHEARWALL PER PLAN W SILL PLATE PER SW PER SW SCHEDULE Project Contact SCHEDULE Kevin Tsuchida PANEL EDGE NAILING PER SW SCHEDULEfax tel 206 624 4760 ex. 22 971 ktsucO6 447h da@ harriottvalentine.com TYPICAL STRAP HOLDOWN AT FLOOR STRAP SCHEDULE (NOT ALL USED) MARK END LENGTH NAILS NAIL SPACING CMST12 44" (98) 1Od x 3" 13/4" CMST14 34" (76) 10d x 3" 13/4" CMSTC16 25" (58) 12d x 31/4" 11/2" CS14 19" (36) 8d x 21/2" 21/16" CS16 14" (26) 8d x 21/2" 21/16" CS18 12" (22) 8d x 21/2" 21/16" CS20 9" (16) 8d x 21/2" 21/16" CS22 8" (14) 8d x 21/2" 21/16" 1. 10d AND 12d DIAMETER = 0.148"; 8d DIAMETER = 0.131 ". 2. USE HALF OF THE REQUIRED NAILS IN EACH MEMBER BEING CONNECTED (i.e. IN EACH END LENGTH). 3/4" = 1'-0" INTERSECTING NON—SHEARWALL EL EDGE NAILING SW SCHEDULE TYPICAL SHEARWALL INTERSECTIONS TYPICAL DOUBLE TOP PLATE 'LAN MULTI —STUD PER PLAN WITH NAILING PER GEN. NOTES TYPICAL MULTIPLE -STUD POST CONSTRUCTION 10 3/4" = 1'-0" 11 a a TYPICAL SHEARWALL SECTION 3/4" = 1'-0" 6'-0" MIN. BETWEEN SPLICES Project Architect LGH Studio 515 Stewart St, Suite 515 Seattle. WA 98101 Project 8 Roberson Remodel 7622 175th St SW Edmonds, WA 98026 (8) 16d @ 4"oc STAGGERED EACH SIDE OF SPLICE (16d @ 12"oc ELSEWHERE) CENTER SPLICE OVER S TU D TYPICAL TOP PLATE SPLICE CONSTRUCTION 3/4" = 1'-0" 12 Issue Date Issue Description 01/05/2021 Permit Set 03/16/2022 Corrections Set Q Building Department Approval Drawing Title STRUCTURAL DETAILS Drawing Number SIO J W 0 0 w z 0 w