Loading...
REVIEWED BLD-BLD2022-0066+Structural_Calculations+1.18.2022_3.35.11_PM+2627411Harriott Valentine Engineers Inc. STRUCTURAL CALCULATIONS Project: Roberson Remodel 7622 175th St SW Edmonds, WA 98026 Architect: LGH Studio 515 Stewart St, Suite 515 Seattle, WA 98101 Structural Engineer: Harriott Valentine Engineers, Inc. 1932 First Avenue, Suite 720 Seattle, WA 98101 tel. 206-624-4760 REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT RECEIVED Jan 20 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 1/5/2022 tel. 206-624-4760 1 fax 447-6971 Page of aFORTE'CM Level, West deck joist 1 piece(s) 11 7/8" THO 110 @ 12" OC PASSED 0 i611111It14 I All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 601 @ 17' 11 1/2" 910 (1.75") Passed (66%) 1.00 1.0 D + 1.0 L (Alt Spans) Shear (Ibs) 601 @ 17' 11 1/2" 1560 Passed (39%) 1.00 1.0 D + 1.0 L (Alt Spans) Moment (Ft-Ibs) 2405 @ 9' 11 3/8" 3160 Passed (76%) 1.00 1.0 D + 1.0 L (Alt Spans) Live Load Defl. (in) 0.332 @ 9' 11 3/16" 0.535 Passed (L/581) 1.0 D + 0.75 L + 0.75 S (Alt Spans) Total Load Defl. (in) 0.408 @ 9' 11 1/4" 0.803 Passed (L/473) 1.0 D + 0.75 L + 0.75 S (Alt Spans) TJ-ProT"' Rating 43 43 Passed • Deflection criteria: LL (L/360) and TL (L/240). • Overhang deflection criteria: LL (2L/360) and TL (2L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A structural analysis of the deck has not been performed. • Deflection analysis is based on composite action with a single layer of 19/32" Panel (20" Span Rating) that is glued and nailed down. • Additional considerations for the TJ-ProT" Rating include: None. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Stud wall - HF 5.50" 5.50" 3.50" 151 602 251 1004 Blocking 2 - Hanger on 11 7/8" HF beam 2.00" Hangers 1.75" / - z 121 492 204 817 See note 1 • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • 1 See Connector grid below for additional information and/or requirements. • z Required Bearing Length / Required Bearing Length with Web Stiffeners Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 3' 6" o/c Bottom Edge (Lu) 7' 4" o/c •TJI joists are only analyzed using Maximum Allowable bracing solutions. -Maximum allowable bracing intervals based on applied load. System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Connector: Simpson Strong -Tie Support Model J1 Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger IUS1.81/11.88 2.00" N/A 10-10dx1.5 2-Strong-Grip • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Snow Vertical Load Location Spacing (0.90) (1.00) (1.15) Comments 1 - Uniform (PSF) 0 to 18' 1 1/2" 12" 15.0 60.0 25.0 Balcony and deck load ForteWEB Software Operator Job Notes Kevin Tsuchida Harriott Valentine Engineers (206) 624-4760 ktsuchida@harriottvalentine.com 11/30/2021 11:34:54 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 2 / 19 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software operator 11/30/2021 11:34:54 PM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 3 / 19 Job Notes Kevin Tsuchida Harriott Valentine Engineers 624-4760 ktsuc ktsuchida@harriottvalentine.com aFORTE'CM Level, West deck structural fascia 1 piece(s) 1 1/4" x 11 7/8" 1.3E TimberStrand@ LSL PASSED o 11> u. 1 u. 14 0 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 711 @ 1' 6 7/8" 886 (1.75") Passed (80%) 1.0 D + 1.0 L (All Spans) Shear (Ibs) 402 @ 1' 11 7/8" 4206 Passed (10%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) -477 @ 1' 6 7/8" 4166 Passed (11%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.009 @ 0 0.200 Passed (2L/999+) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 1 0.011 @ 0 0.200 Passed (2L/999+) 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Overhang deflection criteria: LL (2L/0.2") and TL (2L/0.2"). • Allowed moment does not reflect the adjustment for the beam stability factor. • -470 Ibs uplift at support located at 3' 5/8". Strapping or other restraint may be required. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Total 1 - Beam - HF 1.75" 1.75" 1.50" 153 558 711 Blocking 2 - Beam - HF 1.75' 1.75" 1.50" -92 -378 -470 None 3 - Beam - HF 1.75" 1.75" 1.50" 19 61 80 Blocking • oiocKing raneis are assumes to carry no ioaus appueu uirecuy aoove mem ano me ruu ioau is appueu to me memoer oeing oesigneo. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 4' 7" o/c Bottom Edge (Lu) 4' 7" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Vertical Loads Location (Side) Tributary Width (0.90) (1.00) Comments 0 - Self Weight (PLF) 0 to 4' 7 1/4" N/A 4.3 -- 1 - Point (lb) 0 (Front) N/A 60 240 Balcony and deck load (4 sq ft trib) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Kevin Tsuchida Harriott Valentine Engineers (206) 624-4760 ktsuchida@harriottvalentine.com 11/30/2021 11:34:54 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 4 / 19 aFORTE'CM Level, West deck perp joist 1 piece(s) 11 7/8" THO 110 @ 16" OC PASSED 1 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1707 @ 1' 8 3/4" 2350 (5.25") Passed (73%) 1.00 1.0 D + 1.0 L (All Spans) Shear (Ibs) 1014 @ 1' 6" 1560 Passed (65%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) -1644 @ 1' 8 3/4" 3160 Passed (52%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.044 @ 0 0.200 Passed (2L/944) 1.0 D + 1.0 L (Alt Spans) Total Load Defl. (in) 0.053 @ 0 0.200 Passed (2L/778) 1.0 D + 1.0 L (Alt Spans) TJ-ProT"' Rating 73 50 Passed • Deflection criteria: LL (L/360) and TL (L/240). • Overhang deflection criteria: LL (2L/0.2") and TL (2L/0.2"). • Allowed moment does not reflect the adjustment for the beam stability factor. • -460 Ibs uplift at support located at 4' 11 1/2". Strapping or other restraint may be required. • A structural analysis of the deck has not been performed. • Deflection analysis is based on composite action with a single layer of 19/32" Panel (20" Span Rating) that is glued and nailed down. • Additional considerations for the TJ-ProT" Rating include: None. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Total 1 - Stud wall - HF 5.50" 5.50" 3.50" 311 1396 1707 Blocking 2 - Hanger on 11 7/8" HF beam 2.00" Hanger' 1.75" / - a 56 142/404 42/ See note460 • NOCKing vaneis are assumes to carry no ioaas appuea Direcay aoove tnem ano the Tuu ioaD is appuea co me memoer Deing oesignea. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ' See Connector grid below for additional information and/or requirements. • z Required Bearing Length / Required Bearing Length with Web Stiffeners Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 5' o/c Bottom Edge (Lu) 4' 5" o/c •TJI joists are only analyzed using Maximum Allowable bracing solutions. -Maximum allowable bracing intervals based on applied load. System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger U14 2.00" N/A 14-10dxl.5 6-10dxl.5 Web Stiffeners • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Vertical Loads Location Spacing (0.90) (1.00) Comments 1 - Uniform (PSF) 0 to 5' 1 1/2" 16" 15.0 60.0 Balcony and deck load 2 - Point (lb) 0 N/A 153 711 Structural fascia ForteWEB Software Operator Job Notes Kevin Tsuchida Harriott Valentine Engineers (206) 624-4760 ktsuchida@harriottvalentine.com 11/30/2021 11:34:54 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 5 / 19 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software operator 11/30/2021 11:34:54 PM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 6 / 19 Job Notes Kevin Tsuchida Harriott Valentine Engineers 624-4760 ktsuc ktsuchida@harriottvalentine.com aFORTE'CM Level, West deck header 1 piece(s) 4 x 10 DF No.1 PASSED 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. C Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2497 @ 0 3281 (1.50") Passed (76%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 1697 @ 10 3/4" 3885 Passed (44%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 3717 @ 3' 1 1/2" 4991 Passed (74%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.056 @ 3' 1 1/2" 0.208 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.070 @ 3' 1 1/2" 0.313 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on Nos. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Trimmer - HF 1.50" 1.50" 1.50" 498 1881 784 3163 None 2 - Trimmer - HF 1.50" 1.50" 1 1.50" 498 1881 784 3163 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 6' 3" o/c Bottom Edge (Lu) 6' 3" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Snow Vertical Loads Tributary Width (0.90) (1.00) (1.15) Comments 0 - Self Weight (PLF) 0 to 6' 3" N/A 8.2 Linked from: West 1 - Uniform (PLF) 0 to 6' 3" N/A 151.0 602.0 251.0 deck joist, Support 1 System: Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Kevin Tsuchida Harriott Valentine Engineers (206) 624-4760 ktsuchida@harriottvalentine.com 11/30/2021 11:34:54 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 7 / 19 aFORTE'CM Level, West deck beam powder room 1 piece(s) 3 1/2" x 11 7/8" 2.0E Parallam@ PSL PASSED 1 4' 6" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 3513 @ 2" 7656 (3.50") Passed (46%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 2781 @ 1' 3 3/8" 8035 Passed (35%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 12081 @ T 6 1/2" 19902 Passed (61%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.427 @ 7' 6 1/2" 0.492 Passed (L/414) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.543 @ 76 1/2" 0.738 Passed (L/326) 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Column - HF 3.50" 3.50" 1.61" 748 2602 1084 4434 None 2 - Column - HF 3.50" 3.50" 1.61" 748 2602 1084 4434 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 15' 1" o/c Bottom Edge (Lu) 15' 1" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Snow Vertical Loads Location (Side) Tributary Width (0.90) (1.00) (1.15) Comments 0 - Self Weight (PLF) 0 to 15' 1" N/A 13.0 -- -- 1 - Uniform (PSF) 0 to 15' 1" (Front) 5' 9" 15.0 60.0 25.0 Balcony and deck loads 0 System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Kevin Tsuchida Harriott Valentine Engineers (206) 624-4760 ktsuchida@harriottvalentine.com 11/30/2021 11:34:54 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 8 / 19 aFORTE'CM Level, West deck beam ex wall 1 piece(s) W12X30 (A992) ASTM Steel PASSED Overall Length: 133' 17 8 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 12647 @ 18' 1" 16545 (3.50") Passed (76%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 12186 @ 17' 11 1/2" 63960 Passed (19%) 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-Ibs) 49618 @ 9' 3 7/8" 54723 Passed (91%) 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in) 0.288 @ 9' 1 3/4" 0.597 Passed (L/747) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.425 @ 9' 1 13/16" 0.896 Passed (L/506) 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Bearing reinforcement may be required for support located at 2". • Bearing reinforcement may be required for support located at 18' 1". • Applicable calculations are based on ANSI/AISC 360-16. • A lateral -torsional buckling factor (Cb) of 1.0 has been assumed. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Column - HF 3.50" 3.50" 3.50" 4221 6832 4151 15204 None 2 - Column - HF 3.50" 3.50" 1 3.50" 4322 6832 4268 15422 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) End Bearing Points Bottom Edge (Lu) End Bearing Points Vertical Loads Location (Side) Tributary Width Dead (0.90) Floor Live (1.00) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 18' 3" N/A 30.0 1 - Uniform (PSF) 0 to 18' 3" 6' 5" 15.0 40.0 Ex floor load 2 - Uniform (PSF) 0 to 5' 8" 9' 11.0 - Ex wall above 3 - Uniform (PSF) 11' 8" to 18' 3" 9' 11.0 Ex wall above 4 - Uniform (PSF) 0 to 5' 8" 15' 4" 15.0 25.0 Ex roof load 5 - Uniform (PSF) 11' 8" to 18' 3" 15' 4" 15.0 - 25.0 Ex roof load 6 - Uniform (PLF) 0 to 18' 3" N/A 121.0 492.0 204.0 Linked from: West deck joist, Support 2 System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Kevin Tsuchida Harriott Valentine Engineers (206) 624-4760 ktsuchida@harriottvalentine.com 11/30/2021 11:34:54 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 9 / 19 aFORTE'CM Level, West deck header ex wall 2 piece(s) 2 x 8 HF No.2 PASSED 1 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1579 @ 0 1823 (1.50") Passed (87%) 1.0 D + 1.0 L (All Spans) Shear (Ibs) 870 @ 8 3/4" 2175 Passed (40%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 1283 @ 1' 7 1/2" 2234 Passed (57%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.015 @ 1' 7 1/2" 0.108 Passed (L/999+) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.020 @ 1' 7 1/2" 0.162 Passed (L/999+) 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on Nos. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Trimmer - HF 1.50" 1.50" 1.50" 362 1217 332 1911 None 2 - Trimmer - HF 1.50" 1.50" 1 1.50" 362 1217 332 1911 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) T 3" o/c Bottom Edge (Lu) T 3" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Snow Vertical Loads Tributary Width (0.90) (1.00) (1.15) Comments 0 - Self Weight (PLF) 0 to 3' 3" N/A 5.5 1 - Uniform (PSF) 0 to 3' 3" 6' 5" 15.0 40.0 - Ex floor load Linked from: West 2 - Uniform (PLF) 0 to 3' 3" N/A 121.0 492.0 204.0 deck joist, Support 2 System: Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Kevin Tsuchida Harriott Valentine Engineers (206) 624-4760 ktsuchida@harriottvalentine.com 11/30/2021 11:34:54 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 10 / 19 aFORTE'CM Level, South deck joist 1 piece(s) 11 7/8" TII@ 110 @ 16" OC PASSED 11 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 246 @ 2" 910 (1.75") Passed (27%) 1.00 1.0 D + 1.0 L (All Spans) Shear (Ibs) 246 @ 2" 1560 Passed (16%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 302 @ 2' 7 1/2" 3160 Passed (10%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.008 @ 2' 7 1/2" 0.164 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.010 @ 2' 7 1/2" 0.246 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) TJ-ProT"' Rating 70 50 Passed • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A structural analysis of the deck has not been performed. • Deflection analysis is based on composite action with a single layer of 19/32" Panel (20" Span Rating) that is glued and nailed down. • Additional considerations for the TJ-ProTm Rating include: None. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Hanger on 11 7/8" HF beam 2.00" Hangers 1.75" / 2 52 210 88 350 See note ' 2 - Hanger on 11 7/8" HF beam 2.00" Hangers 1.75" / - z 52 210 88 350 See note ' • He nanger supporrs, me i ocai searing aimension is equal co me wiam or me macenai mac is supporrmg me nanger • s See Connector grid below for additional information and/or requirements. • z Required Bearing Length / Required Bearing Length with Web Stiffeners Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 4' 11" o/c Bottom Edge (Lu) 4' 11" o/c •TJI joists are only analyzed using Maximum Allowable bracing solutions. -Maximum allowable bracing intervals based on applied load. System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger IUS1.81/11.88 2.00" N/A 10-10dxl.5 2-Strong-Grip 2 - Face Mount Hanger IUS1.81/11.88 2.00" N/A 10-10dxl.5 2-Strong-Grip • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Snow Vertical Load Location Spacing (0.90) (1.00) (1.15) Comments 1 - Uniform (PSF) 0 to 5' 3" 16" 15.0 60.0 25.0 Balcony and deck load ForteWEB Software Operator Job Notes Kevin Tsuchida Harriott Valentine Engineers (206) 624-4760 ktsuchida@harriottvalentine.com 11/30/2021 11:34:54 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 11 / 19 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software operator 11/30/2021 11:34:54 PM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 12 / 19 Job Notes Kevin Tsuchida Harriott Valentine Engineers 624-4760 ktsuc ktsuchida@harriottvalentine.com aFORTE'CM Level, South deck ex header 1 piece(s) 4 x 8 DF No-1 PASSED 1 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1691 @ 0 3281 (1.50") Passed (52%) 1.0 D + 1.0 L (All Spans) Shear (Ibs) 1285 @ 8 3/4" 3045 Passed (42%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 2571 @ 3' 1/2" 3322 Passed (77%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.068 @ 3' 1/2" 0.203 Passed (L/999+) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.091 @ T 1/2" 0.304 Passed (L/805) 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Trimmer - HF 1.50" 1.50" 1.50" 431 1260 201 1892 None 2 - Trimmer - HF 1.50" 1.50" 1 1.50" 431 1260 201 1892 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 6' 1" o/c Bottom Edge (Lu) 6' 1" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Snow Vertical Loads Tributary Width (0.90) (1.00) (1.15) Comments 0 - Self Weight (PLF) 0 to 6' 1" N/A 6.4 Linked from: South 1 - Uniform (PLF) 0 to 6' 1" N/A 39.0 157.5 66.0 deck joist, Support 2 2 - Uniform (PSF) 0 to 6' 1" 6' 5" 15.0 40.0 - Ex floor load System: Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Kevin Tsuchida Harriott Valentine Engineers (206) 624-4760 ktsuchida@harriottvalentine.com 11/30/2021 11:34:54 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 13 / 19 aFORTE'CM Level, South deck beam 1 piece(s) 1 1/4" x 11 7/8" 1.3E TimberStrand@ LSL PASSED � I � All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 760 @ 7' 4 1/2" 1331 (1.50") Passed (57%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 525 @ 6' 4 5/8" 4206 Passed (12%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 1304 @ 3' 9 1/4" 4166 Passed (31%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.058 @ 3' 9 1/4" 0.240 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.073 @ T 9 1/4" 0.360 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Column - HF 3.50" 3.50" 1.50" 163 594 249 1006 None 2 - Hanger on 11 7/8" HF beam 2.00" Hanger' 1.50" 163 594 249 1006 See note' • At hanger supports, the I otal Bearing dimension Is equal to the Width of the material that Is supporting the hanger • ' See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 7' 5" o/c Bottom Edge (Lu) 7' 5" o/c -Maximum allowable bracing intervals based on applied load. System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger Connector not found N/A N/A N/A N/A • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Snow Vertical Loads Location (Side) Tributary Width (0.90) (1.00) (1.15) Comments 0 - Self Weight (PLF) 0 to 7' 4 1/2" N/A 4.3 Linked from: South 1 - Uniform (PLF) 0 to 7' 6 1/2" (Front) N/A 39.0 157.5 66.0 deck joist, Support 1 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Kevin Tsuchida Harriott Valentine Engineers (206) 624-4760 ktsuchida@harriottvalentine.com 11/30/2021 11:34:54 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 14 / 19 aFORTE'CM Level, South deck header 2 piece(s) 2 x 8 HF No-2 PASSED 1 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 859 @ 0 1823 (1.50") Passed (47%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 741 @ 8 3/4" 2175 Passed (34%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 705 @ 11" 2234 Passed (32%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.014 @ 1' 11 9/16" 0.142 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.017 @ 1' 11 9/16" 0.213 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Trimmer - HF 1.50" 1.50" 1.50" 182 636 266 1084 None 2 - Trimmer - HF 1.50" 1.50" 1 1.50" 89 298 125 512 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 4' 3" o/c Bottom Edge (Lu) 4' 3" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Snow Vertical Loads Tributary Width (0.90) (1.00) (1.15) Comments 0 - Self Weight (PLF) 0 to 4' 3" N/A 5.5 1 - Uniform (PSF) 0 to 4' 3" 1' 4" 15.0 60.0 25.0 Balcony and deck load Linked from: South 2 - Point (lb) 11" N/A 163 594 249 deck NS beam, Support 2 System: Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Reyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to NWW.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Kevin Tsuchida Harriott Valentine Engineers (206) 624-4760 ktsuchida@harriottvalentine.com 11/30/2021 11:34:54 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 15 / 19 aFORTE'CM Level, North deck joist 1 piece(s) 11 7/8" TII@ 110 @ 16" OC PASSED 10' f Fill All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. I Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 189 @ 4' 11" 910 (1.75") Passed (21%) 1.00 1.0 D + 1.0 L (Alt Spans) Shear (Ibs) 189 @ 4' 11" 1560 Passed (12%) 1.00 1.0 D + 1.0 L (Alt Spans) Moment (Ft-Ibs) 178 @ 3' 3/8" 3160 Passed (6%) 1.00 1.0 D + 1.0 L (Alt Spans) Live Load Defl. (in) 0.004 @ 3' 1/16" 0.128 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (Alt Spans) Total Load Defl. (in) 0.005 @ 3' 1/8" 0.192 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (Alt Spans) TJ-ProT"' Rating 72 50 Passed • Deflection criteria: LL (L/360) and TL (L/240). • Overhang deflection criteria: LL (2L/360) and TL (2L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A structural analysis of the deck has not been performed. • Deflection analysis is based on composite action with a single layer of 19/32" Panel (20" Span Rating) that is glued and nailed down. • Additional considerations for the TJ-ProT" Rating include: None. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Plate on steel - HF 6.00" 6.00" 3.50" 63 252 105 420 Blocking 2 - Hanger on 11 7/8" HF beam 2.00" Hangers 1.75" / - z 39 167 67 273 See note 1 • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • 1 See Connector grid below for additional information and/or requirements. • z Required Bearing Length / Required Bearing Length with Web Stiffeners Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 4' 11" o/c Bottom Edge (Lu) 4' 11" o/c •TJI joists are only analyzed using Maximum Allowable bracing solutions. -Maximum allowable bracing intervals based on applied load. System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Connector: Simpson Strong -Tie Jill Support Mode1JJ Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger IUS1.81/11.88 2.00" N/A 10-10dx1.5 2-Strong-Grip • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Snow Vertical Load Location Spacing (0.90) (1.00) (1.15) Comments 1 - Uniform (PSF) 0 to 5' 1" 16" 15.0 60.0 25.0 Balcony and deck load ForteWEB Software Operator Job Notes Kevin Tsuchida Harriott Valentine Engineers (206) 624-4760 ktsuchida@harriottvalentine.com 11/30/2021 11:34:54 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 16 / 19 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software operator 11/30/2021 11:34:54 PM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 17 / 19 Job Notes Kevin Tsuchida Harriott Valentine Engineers 624-4760 ktsuc ktsuchida@harriottvalentine.com aFORTE'CM Level, North deck beam 1 piece(s) 5 1/8" x 15" 24F-V4 DF Glulam PASSED All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 3462 @ 1 1/4" 9161 (2.75") Passed (38%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 2932 @ 1' 5 3/4" 13581 Passed (22%) 1.00 1.0 D + 1.0 L (All Spans) Pos Moment (Ft-Ibs) 21130 @ 12' 11 3/4" 36831 Passed (57%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.766 @ 12' 11 3/4" 0.858 Passed (L/404) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 1.017 @ 12' 11 3/4" 1.288 Passed (L/304) 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 0.96 that was calculated using length L = 25' 9". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on Nos. Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Column - HF 2.75" 2.75" 1.50" 856 2453 1022 4331 Blocking 2 - Column - HF 5.50" 5.50" 1.50" 871 2496 1040 4407 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 26' 2" o/c Bottom Edge (Lu) 26' 2" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Snow Vertical Loads Location (Side) Tributary Width (0.90) (1.00) (1.15) Comments 0 - Self Weight (PLF) 0 to 26' 2 1/4" N/A 18.7 Linked from: North 1 - Uniform (PLF) 0 to 26' 2 1/4" (Front) N/A 47.3 189.0 78.8 deck joist, Support 1 System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Kevin Tsuchida Harriott Valentine Engineers (206) 624-4760 ktsuchida@harriottvalentine.com 1/5/2022 5:02:17 PM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 1 / 1 aFORTE'CM Level, North deck header 2 piece(s) 2 x 8 HF No-2 PASSED 1 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 712 @ 0 1823 (1.50") Passed (39%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 493 @ 8 3/4" 2175 Passed (23%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 896 @ 2' 7 1/2" 2234 Passed (40%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.030 @ 2' 7 1/2" 0.175 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.037 @ 2' 7 1/2" 0.262 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on Nos. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Trimmer - HF 1.50" 1.50" 1.50" 144 539 219 902 None 2 - Trimmer - HF 1.50" 1.50" 1 1.50" 144 539 219 902 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 5' 3" o/c Bottom Edge (Lu) 5' 3" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Snow Vertical Loads Tributary Width (0.90) (1.00) (1.15) Comments 0 - Self Weight (PLF) 0 to 5' 3" N/A 5.5 1 - Uniform (PSF) 0 to 5' 3" 1' 4" 15.0 60.0 25.0 Balcony and deck load Linked from: North 2 - Uniform (PLF) 0 to 5' 3" N/A 29.3 125.3 50.3 deck joist, Support 2 System: Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Reyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to NWW.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Kevin Tsuchida Harriott Valentine Engineers (206) 624-4760 ktsuchida@harriottvalentine.com 11/30/2021 11:34:54 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Roberson Page 19 / 19 LAMINATED BEAMS Durable Beam is Here', • 'pity`°_ - ' .K _ - Need a strong, beautiful • aa ineered laminated beam that's highly decav resistant AM;l� Alaska Yellow Cedar Specify and order your ME Durable Laminated Beams today! Boise Cascade ® Engineered Wood Products Please Note: Durable beams are intended for wet conditions of use above direct ground or water contact. 4 Bending Fb [psi] Horizontal Modulus of Compression Parallel Compression Compression Tension Zone Zone in Shear Elasticity to Grain Perp to Grain Product Grade in Tension Tension F, [psi] E [psi] Fc [psi] Fc [psi] Alaska Yellow 20E-V12 2000 1400 265 1,500,000 1500 560 Cedar 20E-V12 Notes: • Reduction factors shall be applied to design stresses in wet -use conditions, see information on the right. • For fastener design, an equivalent specific gravity of 0.46 shall be used. • Alaska Yellow Cedar Beams come in a variety of widths and depths including 81/4" and 103%" sizes. • This product is also available in a balanced layup, 20E-V13 grade. • Evaluation Report: APA PR-1­313. National building codes require the use of naturally durable species or pressure preservative treated wood in exterior applications. Specifically addressing glulam products in these applications, the International Residential Code states the following: R319.1.5 Exposed glued -laminated timbers. The portions of glued -laminated timbers that form the structural supports of a building or other structure and are exposed to weather and not properly protected by a roof, eave or similar covering shall be pressure treated with preservative, or be manufactured from naturally durable or preservative -treated wood. Alaska Yellow Cedar (AYC) is one such durable specie that BOISE GLULAM° currently manufactures. When designing structural components in exterior applications, moisture content shall be considered. Wood strength and stiffness properties decrease with an increase in moisture content. Allowable glulam design values assume a moisture content of 16% or less. If a beam or column application Allowable Design Stresses ................................................ 2 Wet -Use Reduction Factors, Wet -Use Conditions ............................ 2 N BOISE GLULAM° CEDAR Alaska Yellow Cedar 22F-V14 Design Values...............................3 Alaska Yellow Cedar Strength and Hardness Comparisons ..................... 3 BOISE GLULAM° CEDAR Load Tables U 100% Load Duration - Dry -Use Conditions 31/8" 20E-V12/AYC Grade ........................................... 4 0 51/8" 20E-V12/AYC Grade ........................................... 5 63/4" 20E-V12/AYC Grade ........................................... 6 115%Snow Load Duration - Dry -Use Conditions 31/8" 20E-V12/AYC Grade ........................................... 7 51/8" 20E-V12/AYC Grade ........................................... 8 63/4" 20E-V12/AYC Grade ........................................... 9 Wet -Use Reduction Factors Stress Reduction Factor Bending 0.8 Shear 0.875 Modulus of Elasticity 0.833 Tension 0.8 Compression Par. to Grain 0.73 Compression Perp to Grain 0.53 is subjected to conditions that may cause a sustained moisture content greater than 16%, wet -use factors shall be applied. Those values are shown with the allowable stress value table, per the 2012 National Design Specification (NDS) for Wood Construction: Ultimately, it is a project's design professional of record and/or building official that should determine whether an exposed application shall be considered wet -use. This determination depends on the local climate, the amount of exposure, proximity to soil, etc. If a determination is not made by the project's design or code enforcement official, wet -use conditions should be assumed. It is recommended that exterior column applications be considered wet use, due to the higher probability of exposure. Beam load/span tables for both dry and wet conditions are listed on pages 4-18. Cedar glulam products shall not be used in ground or below ground contact applications, or marine environments. The project's designer should consult a connector/fastener manufacturer in regards to coating recommendations for those products. BOISE GLULAM® CEDAR Load Tables 125% Non -Snow Load Duration - Dry -Use Conditions 31/8" 20E-V12/AYC Grade .......................................... 10 51/8" 20E-V12/AYC Grade .......................................... 11 63/4" 20E-V12/AYC Grade .......................................... 12 100% Load Duration - Wet -Use Conditions 31/8" 20E-V12/AYC Grade .......................................... 13 51/8" 20E-V12/AYC Grade .......................................... 14 63/4" 20E-V12/AYC Grade .......................................... 15 115% Snow Load Duration - Wet -Use Conditions 31/8" 20E-V12/AYC Grade .......................................... 16 51/8" 20E-V12/AYC Grade .......................................... 17 63/4" 20E-V12/AYC Grade .......................................... 18 BOISE GLULAM® CEDAR Column Table & Allowable Stresses .................. 19 Features....................................................... Back Cover Cedar Durable Beam Guide 05/09/2016 BOISE GLULA NUCEDAR4ft- Alaska Yellow 3 CedarDesign Depth Weight= Allowable Shear Allowable Moment (1)(2) M 6 4.2 3313 3125 56.3 7'/2 5.3 4141 4883 109.9 9 6.3 4969 7031 189.8 10'/2 7.4 5797 9570 301.5 12 8.4 6625 12500 450.0 13'/2 9.5 7453 15820 640.7 T/8 15 10.5 8281 19531 878.9 16'/2 11.6 9109 23633 1169.8 18 12.7 9938 28125 1518.8 19'/2 13.7 10766 33008 1931.0 21 14.8 11594 38034 2411.7 22'/2 15.8 12422 43361 2966.3 24 16.9 13250 49018 3600.0 6 6.9 5433 5125 92.3 7'/2 8.6 6791 8008 180.2 9 10.4 8149 11531 311.3 10'/2 12.1 9507 15695 494.4 12 13.8 10865 20500 738.0 13'/2 15.6 12223 25642 1050.8 5'/e 15 17.3 13581 31324 1441.4 16'/2 19.0 14939 37543 1918.5 18 20.8 16298 44292 2490.8 19'/2 22.5 17656 51567 3166.8 21 24.2 19014 59364 3955.2 22'/2 25.9 20372 67679 4864.7 24 27.7 21730 76509 5904.0 7'/2 11.4 8944 10547 237.3 9 13.7 10733 15188 410.1 10'/2 15.9 12521 20381 651.2 12 18.2 14310 26267 972.0 13'/2 20.5 16099 32854 1384.0 15 22.8 17888 40136 1898.4 63/a 16'/2 25.1 19676 48104 2526.8 18 27.3 21465 56751 3280.5 19'/2 29.6 23254 66073 4170.9 21 31.9 25043 76063 5209.3 221/2 34.2 26831 86717 6407.2 24 36.5 28620 98030 7776.0 Notes: 1. Allowable moment calculated using glulam volume factor (C) with a span length of 21 ft. Allowable moment shall be multiplied by (21/Span Length [ft]p"0 for longer spans. 2. Allowable moment values assume simple span applications. Design values listed per dry -use conditions. For wet -use applications, apply corresponding factors per table on page 2. 3. Alaska Yellow Cedar beams come in a variety of widths and depths including 8%" and 10%" sizes. This product is also available in a balanced layup, 20E- V13 grade. Alaska Yellow Cedar Durable Beam Guide 05/09/2016 Melton framing (Updated for Roberson Remodel) Garage beam, Use 6x8 L = 10.33 ft w = 11 psf DL * (8.25-12.58 ft trib), L = 0-10.33 ft w = 39 Ib DL + 167 Ib ILL + 67 Ib SL / 16/12 ft trib, L = 0-10.33 ft P=16011bWL+1015lbEL, L=1.42ft Ri,asD = 3.11 k 0.85 k) Ri,LRFD = 3.94 k (-1.67 k) Rj,ASD = 1.82 k Rj,LRFD = 2.13 k V = 3.11 k M = 5.25 k-ft Vr = 4.52 k M r = 5.42 k-ft OD+L = .234 in, L/529 Garage post, use 6x6 above 30"sq footing Proof ridge = 3070 1 b Pgarage beam = 1820 1 b Pgarage beam = 1820 1 b Pexgaragebeam = 55 psf * 12.75 ft trib * 5.83 ft trib = 4089 Ib Ptot = 10799 Ib Pr = 12251 Ib y`rirz�y��1 U.S. Seismic Design Maps U[A 7622 175th St SW, Edmonds, WA 98026, USA Latitude, Longitude: 47.8400814,-122.3368257 OSH PD v 174th St SW Superior Fibers =r 19 D �,�rst SW fD 11 7 75th St SW 176th St SW Go gie Map data 02020 Date 6/1712020, 9:32:40 AM Design Code Reference Document IBC-2015 Risk Category II Site Class D - Stiff Soil Type Value Description SS 1.301 MCER ground motion. (for 0.2 second period) S, 0.51 MCER ground motion. (for 1.0s period) SMS 1.301 Site -modified spectral acceleration value SM1 0.766 Site -modified spectral acceleration value SDS 0.867 Numeric seismic design value at 0.2 second SA SDI 0.51 Numeric seismic design value at 1.0 second SA Type Value Description SDC D Seismic design category Fa 1 Site amplification factor at 0.2 second F 1.5 Site amplification factor at 1.0 second PGA 0.534 MCER peak ground acceleration FPGA 1 Site amplification factor at PGA PGAM 0.534 Site modified peak ground acceleration T, 6 Long -period transition period in seconds SsRT 1.301 Probabilistic risk -targeted ground motion. (0.2 second) SsUH 1.346 Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 2.022 Factored deterministic acceleration value. (0.2 second) S1 RT 0.51 Probabilistic risk -targeted ground motion. (1.0 second) S1 UH 0.545 Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration. S1 D 0.837 Factored deterministic acceleration value. (1.0 second) PGAd 0.773 Factored deterministic acceleration value. (Peak Ground Acceleration) CRS 0.966 Mapped value of the risk coefficient at short periods CR1 0.937 Mapped value of the risk coefficient at a period of 1 s https://seismicmaps.org 1/2 6/17/2020 U.S. Seismic Design Maps DISCLAIMER While the information presented on this website is believed to be correct, S.E.A.O.Q. /OSHPD and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in this web application should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. SEAOC / OSHPD do not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the seismic data provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the search results of this website. https://seismicmaps.org 2/2 Harriott Valentine Engineers Inc. SEISMIC DESIGN -Addition ASCE 7-16 Equivalent Lateral Force Procedure RISK Category Seismic Design Category Importance Factor Site Class Ss S1 Fa Fv Ct x hn SMs = Fa"Ss SM1 = Fv"S1 SDS = (2/3)"SMS SD1 = (2/3)"SM1 Period Ta = Ct*hn"x To Ts Sa R Do Cd Section 12.8 (ELF) ok? II Table 1.5-1 D Table 11.6-1 1.00 Table 1.5-2 D Table 20.3-1 per Geotech or DEFAULT 130.10 %g (from SEAOC/OSHPD website tool) 51.00 %g (from SEAOC/OSHPD website tool) 1.20 Table 11.4-1 USE Fa=1.2 for DEFAULT Site Class D 1.90 Table 11.4-2 0.02 Table 12.8-2 0.75 Table 12.8-2 9.00 feet (height to highest level) 1.5612 Eq.11.4-1 0.9690 Eq.11.4-2 1.0408 g Eq. 11.4-3 0.6460 g Eq. 11.4-4 0.1039 s Eq. 12.8-7 0.1241 s per section 11.4.6 0.6207 s per section 11.4.6 0.0939 g per section 11.4.6 6.5 Table 12.2-1 2.5 Table 12.2-1 4 Table 12.2-1 Yes Table 12.6-1 Equivalent Lateral Force Procedure (section 12.8) Cs 0.1601 Eq. 12.8-2 W, weight 19,157 lb per table below QE 3,067lb Eq. 12.8-1 Vertical Force Distribution (section 12.8.3) k = 1.00 Floor Seismic Floor Wall Wall Total (LRFD) (ASD) Level Hx Area Dead Ld Wt. Length Wt. Wt. WxHx Cvx QE 0.7QE (ft) (ft2) (psf) (k) (ft) (k) (k) (k-ft) (%) (k) (k) Addition walls 9.00 1023 15 15.3 77 3.8 19.2 172.4 100.0 3.07 2.15 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel. 206-624-4760 1 fax 447-6971 19.16 172.41 100.00 3.07 2.15 11 /30/2021 Page of Harriott Valentine Engineers Inc. SEISMIC DESIGN - Ex buliding ASCE 7-16 Equivalent Lateral Force Procedure RISK Category Seismic Design Category Importance Factor Site Class Ss S1 Fa Fv Ct x hn SMs = Fa"Ss SM1 = Fv"S1 SDS = (2/3)"SMS SD1 = (2/3)"SM1 Period Ta = Ct*hn"x To Ts Sa R Do Cd Section 12.8 (ELF) ok? II Table 1.5-1 D Table 11.6-1 1.00 Table 1.5-2 D Table 20.3-1 per Geotech or DEFAULT 130.10 %g (from SEAOC/OSHPD website tool) 51.00 %g (from SEAOC/OSHPD website tool) 1.20 Table 11.4-1 USE Fa=1.2 for DEFAULT Site Class D 1.90 Table 11.4-2 0.02 Table 12.8-2 0.75 Table 12.8-2 21.33 feet (height to highest level) 1.5612 Eq.11.4-1 0.9690 Eq.11.4-2 1.0408 g Eq. 11.4-3 0.6460 g Eq. 11.4-4 0.1985 s Eq. 12.8-7 0.1241 s per section 11.4.6 0.6207 s per section 11.4.6 1.0408 g per section 11.4.6 6.5 Table 12.2-1 2.5 Table 12.2-1 4 Table 12.2-1 Yes Table 12.6-1 Equivalent Lateral Force Procedure (section 12.8) Cs 0.1601 Eq. 12.8-2 W, weight 80,565 lb per table below QE 12,900lb Eq. 12.8-1 Vertical Force Distribution (section 12.8.3) k = 1.00 Floor Seismic Floor Wall Wall Total (LRFD) (ASD) Level Hx Area Dead Ld Wt. Length Wt. Wt. WxHx Cvx QE 0.7QE (ft) (ft2) (psf) (k) (ft) (k) (k) (k-ft) (%) (k) (k) Ex main walls 17.00 1843 15 27.6 182 8.3 35.9 610.4 61.0 7.86 5.51 Ex basement w; 8.75 1843 15 27.6 182 17.0 44.7 390.8 39.0 5.04 3.52 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel. 206-624-4760 1 fax 447-6971 80.57 1001.15 100.00 12.90 9.03 11 /30/2021 Page of Harriott Valentine Engineers Inc. WIND DESIGN ASCE 7-10 Simplified Envelope Method (Chapter 28) ps = ,� Kzt I ps30 Part of Figure 28.6-1 - Adjustment Factor for Building Height and Exposure, Mean Roof Height Exposure (ft) B C D 15 1.00 1.21 1.47 16 1.00 1.23 1.49 17 1.00 1.24 1.50 18 1.00 1.26 1.52 19 1.00 1.27 1.53 20 1.00 1.29 1.55 21 1.00 1.30 1.56 22 1.00 1.31 1.57 23 1.00 1.33 1.59 24 1.00 1.34 1.60 25 1.00 1.35 1.61 26 1.00 1.36 1.62 27 1.00 1.37 1.63 28 1.00 1.38 1.64 29 1.00 1.39 1.65 30 1.00 1.40 1.66 Part of Figure 28.6-1 - Method 2 Desian Wind Pressure. Ds30 = adjustment factor = 1.00 I = importance factor = 1.00 Kzt = topographic factor = 1.00 Zone Computation a = 10% of least horizontal dimension or 0.4 x h, whichever is smaller, but not less than either 4% of least horizontal dimen- sion or 3 feet. w = 30.75 ft x 0.1 = 3.08 ft h= 21.33ft x0.4= 8.53ft w = 30.75 ft x 0.04 = 1.23 ft a = 3.00 ft 2a = 6.00 ft Zone B - end zone of roof Zone A - end zone of wall Zone D - interior zone of roof Zone C - interior zone of wall Basic Speed Roof Angle Roof Pitch Horizontal Pressures (psf) A B C D 110 0 to 5 flat 19.2 -10.0 12.7 -5.9 10 2 21.6 -9.0 14.4 -5.2 15 3 24.1 -8.0 16.0 -4.6 20 4 26.6 -7.0 17.7 -3.9 25 6 24.1 1 3.9 17.4 4.0 30 to 45 7 to 12 21.6 1 14.8 17.2 11.8 Desian Wind Pressure, Ds Basic Speed Roof Angle Roof Pitch Horizontal Pressures (psf) A B C D 110 0 to 5 flat 19.2 -10.0 12.7 -5.9 10 2 21.6 -9.0 14.4 -5.2 15 3 24.1 -8.0 16.0 -4.6 20 4 26.6 -7.0 17.7 -3.9 25 6 24.1 3.9 17.4 4.0 30 to 45 7 to 12 21.6 1 14.8 17.2 11.8 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206-624-4760 1 fax 447-6971 11/30/2021 Page of Roberson Residence lateral design Wind Design Exposure Surface roughness B (suburban or wooded areas) for approx. % mile Exposure B Topographic factor Not located in the upper one-half of a hill or ridge KZt = 1.0 Vertical Wind distribution Interior wind = (16.0 psf WL * 4.5 ft trib wall) = 72 * .6 = 43.2 plf .6 WL Exterior wind = (24.1 psf WL * 4.5 ft trib wall) = 108.5 * .6 = 65.1 plf .6 WL Horizontal lateral force distribution North wall 2150 lb / 2 = 1075 lb EL (65.1 plf * 3 ft) + (43.2 plf * (45/2)-3 ft) = 1038 lb WL South wall 2150 lb / 2 = 1075 lb EL (65.1 plf * 3 ft) + (43.2 plf * (45/2)-3 ft) = 1038 lb WL West wall 2150 lb / 2 = 1075 lb EL (65.1 plf * 3 ft) + (43.2 plf * (16/2)-3 ft) = 412 lb WL East wall 2150 lb / 2 + 9030 lb / 2 = 5590 lb EL (43.2 plf * (16/2) ft) + (24.1 psf * 17.08 ft trib height * 3 ft trib width) + (16.0 psf * 17.08 ft trib height * 26.5/2-3 ft trib width) = 1038 lb WL = 4382 lb WL Harriott Valentine Engineers Inc. LATERAL FORCE DISTRIBUTION (SEISMIC) East-West va' = allowable shear values multiplied by (1.25-0.125 ' h/1) Walls Below Deck for wall aspect ratios greater than 2:1, and only for seismic .6D+.7E D+.7E WALL F V_ V_ L v SW h h/I va' M of M of M of OT DL max T HD TL C POST (lb) (abv) (total) (ft) (plf) (ft) (Ibft) (abv) (total) (lb) (lb) (lb) (lb) (lb) North 1075 0 1075 8.92 157 SW1 9.00 1.01 ---- 12578 0 12578 1410 265 1145 HDU2 106 1516 (2)2x6 South 1075 0 1075 4.42 316 SW2 9.00 2.04 347 12578 0 12578 2846 131 2714 HDU4 0 2846 (2)2x6 rho = 1.30 North -South va' = allowable shear values multiplied by 2w/h Walls Below Deck for wall aspect ratios greater than 2:1, and only for seismic .6D+.7E D+.7E WALL F V_ V_ L v SW h h/I va' Mot Mot Mot OT DL max T HD TL C POST (lb) (abv) (total) (ft) (plf) (ft) (Ibft) (abv) (total) (lb) (lb) (lb) (lb) (lb) West 1075 0 1075 23.59 59 SW1 9.00 0.84 ---- 12578 0 12578 533 1744 -1211 --- 2907 3440 (2)2x6 East 5590 0 5590 18.08 402 SW3 9.00 0.50 ---- 65403 0 65403 3617 1052 2565 (2)MSTAM24 1753 5371 (2)2x6 rho = 1.30 LATERAL FORCE DISTRIBUTION (WIND) East-West Walls Below Deck .6D+.6W D+.6W WALL F V V L v_ SW h Mot Mot Mot OT DL max T HD TL C POST (lb) (abv) (total) (ft) (plf) (ft) (Ibft) (abv) (total) (lb) (lb) (lb) (lb) (lb) North 1038 0 1038 8.92 151 SW1 9.00 1.01 ---- 12145 0 12145 1362 265 1097 HDU2 106 1467 (2)2x6 South 1038 0 1038 4.42 305 SW2 9.00 2.04 485 12145 0 12145 2748 131 2616 HDU4 0 2748 (2)2x6 North -South Walls Below Deck .6D+.6W D+.6W WALL F V V L v_ SW h Mot Mot Mot OT DL max T HD TL C POST (lb) (abv) (total) (ft) (plf) (ft) (Ibft) (abv) (total) (lb) (lb) (lb) (lb) (lb) West 412 0 412 23.59 23 SW1 9.00 0.84 ---- 4820 0 4820 204 1744 -1540 --- 2907 3111 (2)2x6 East 4382 0 4382 18.08 315 SW3 9.00 0.50 ---- 51269 0 51269 2836 1052 1784 (2)MSTAM24 1753 4589 (2)2x6 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 1/5/2022 tel 206-624-4760 1 fax 447-6971 Page of Anchor DesignerTM Software Version 2.7.6990.8 1.Proiect information Customer company: Customer contact name: Customer e-mail: Comment: 2. Input Data & Anchor Parameters General Design method:ACI 318-14 Units: Imperial units Anchor Information: Anchor type: Bonded anchor Material: F1554 Grade 36 Diameter (inch): 0.625 Effective Embedment depth, hef (inch): 10.000 Code report: ICC-ES ESR-2508 Anchor category: - Anchor ductility: Yes hmin (inch): 13.13 cac (inch): 17.02 Cmin (inch): 1.75 Smin (inch): 3.00 Recommended Anchor Anchor Name: SET-XPO - SET-XP w/ 5/8" 0 F1554 Gr. 36 Code Report: ICC-ES ESR-2508 Company: Date: 11/9/2021 Engineer: Page: 1/5 Project: Address: Phone: E-mail: Project description: LRFD loads 0.9DL+1.OEL = 1617 lb 0.9DL+1.OWL = 1873 lb Location: Fastening description: Base Material Concrete: Normal -weight Concrete thickness, h (inch): 24.00 State: Cracked Compressive strength, f'� (psi): 2500 4Jo,v: 1.0 Reinforcement condition: A tension, A shear Supplemental reinforcement: Not applicable Reinforcement provided at corners: No Ignore concrete breakout in tension: No Ignore concrete breakout in shear: No Hole condition: Dry concrete Inspection: Periodic Temperature range, Short/Long: 150/110°F Ignore 6do requirement: Not applicable Build-up grout pad: No Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Anchor Designer TM Software Version 2.7.6990.8 Load and Geometry Load factor source: ACI 318 Section 5.3 Load combination: not set Seismic design: Yes Anchors subjected to sustained tension: No Ductility section for tension: 17.2.3.4.3 (c) is satisfied Ductility section for shear: 17.2.3.5.3 (b) is satisfied Oo factor: not set Apply entire shear load at front row: No Anchors only resisting wind and/or seismic loads: Yes Strength level loads: Nua [lb]: 1617 Vuax [lb]: 0 Way [lb]: 0 <Figure 1> 0 lb Company: Date: 11/9/2021 Engineer: Page: 2/5 Project: Address: Phone: E-mail: Z 1617 lb 0lb Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Anchor Designer"' Software Version 2.7.6990.8 <Figure 2> Company: Date: 11 /9/2021 Engineer: Page: 3/5 Project: Address: Phone: E-mail: Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Anchor DesignerT"' Software Version 2.7.6990.8 Company: Date: 11/9/2021 Engineer: Page: 4/5 Project: Address: Phone: E-mail: 3. Resulting Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, Nu (lb) Vu (lb) Way (Ib) 1(Vuax)2+(Vuay)2 (lb) 1 1617.0 0.0 0.0 0.0 Sum 1617.0 0.0 0.0 0.0 Maximum concrete compression strain (%e): 0.00 Maximum concrete compression stress (psi): 0 Resultant tension force (lb): 1617 Resultant compression force (lb): 0 Eccentricity of resultant tension forces in x-axis, e'Nx (inch): 0.00 Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00 4. Steel Strength of Anchor in Tension (Sec. 17.4.1 Nsa (lb) 0 ON. (lb) 13110 0.75 9833 5. Concrete Breakout Strength of Anchor in Tension (Sec. 17.4.2) Nb = kc,i f'chef' 5 (Eq. 17.4.2.2a) kc Yc (psi) het (in) Nb (Ib) 17.0 1.00 2500 10.000 26879 0.750Ncb = 0.750 (ANc/ANce)7ed,NYo,NYop,NNb (Sec. 17.3.1 & Eq. 17.4.2.1a) ANc (in') ANco (in' ca,.m (in) V'ed,N PC,N V'cp,N Nb (Ib) 0 0.750Nci) (lb) 180.00 900.00 3.00 0.760 1.00 1.000 26879 0.75 2298 6. Adhesive Strength of Anchor in Tension (Sec. 17.4.5) 2k,cr = Tkcrfshort-te KsataN.seis A,, (psi) fshort-term { sat aUseis Zk,cr (psi) 435 1.72 1.00 1.00 748 Nba = azcr;cdahef (Eq. 17.4.5.2) Aa Tcr (psi) da (in) her (in) Nb. (lb) 1.00 748 0.63 10.000 14691 0.75^ = 0.750 (ANa1 ANao) %d,NaY'cp,NaNba (Sec. 17.3.1 & Eq. 17.4.5.1 a) AN, (m2) ANao (in') cNa (in) ca,min (in) V edNe Vp,Na Nao (lb) 0 0.75^ (lb) 96.56 258.98 8.05 3.00 0.812 1.000 14691 0.55 1834 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Anchor Designer"' Software Version 2.7.6990.8 IN Company: Date: 11/9/2021 Engineer: Page: 5/5 Project: Address: Phone: E-mail: 11. Results 11. Interaction of Tensile and Shear Forces (Sec. D.7)? Tension Factored Load, Nua (lb) Design Strength, oNn (lb) Ratio Status Steel 1617 9833 0.16 Pass Concrete breakout 1617 2298 0.70 Pass Adhesive 1617 1834 0.88 Pass (Governs) SET-XP w/ 5/8" 0 F1554 Gr. 36 with hef = 10.000 inch meets the selected design criteria. 12. Warnings - When cracked concrete is selected, concrete compressive strength used in concrete breakout strength in tension, adhesive strength in tension and concrete pryout strength in shear for SET-XP adhesive anchor is limited to 2,500 psi per ICC-ES ESR-2508 Section 5.3. Per designer input, ductility requirements for tension have been determined to be satisfied — designer to verify. Per designer input, ductility requirements for shear have been determined to be satisfied — designer to verify. Designer must exercise own judgement to determine if this design is suitable. Refer to manufacturer's product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Anchor DesignerTM Software Version 2.7.6990.8 1.Proiect information Customer company: Customer contact name: Customer e-mail: Comment: 2. Input Data & Anchor Parameters General Design method:ACI 318-14 Units: Imperial units Anchor Information: Anchor type: Cast -in -place Material: F1554 Grade 36 Diameter (inch): 0.625 Effective Embedment depth, hef (inch): 4.000 Anchor category: - Anchor ductility: Yes hmin (inch): 5.38 Cmin (inch): 3.75 Smin (inch): 3.75 Company: Date: 11/9/2021 Engineer: Page: 1/5 Project: Address: Phone: E-mail: Project description: LRFD loads 0.9DL+1.OEL = 3870 lb 0.9DL+1.OWL = 4384 lb Location: Fastening description: Base Material Concrete: Normal -weight Concrete thickness, h (inch): 9.00 State: Cracked Compressive strength, f'� (psi): 2500 4Jo,v: 1.0 Reinforcement condition: A tension, A shear Supplemental reinforcement: Not applicable Reinforcement provided at corners: No Ignore concrete breakout in tension: No Ignore concrete breakout in shear: No Ignore 6do requirement: No Build-up grout pad: No Recommended Anchor Anchor Name: Heavy Hex Bolt - 5/8" 0 Heavy Hex Bolt, F1554 Gr. 36 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Anchor Designer TM Software Version 2.7.6990.8 Load and Geometry Load factor source: ACI 318 Section 5.3 Load combination: not set Seismic design: Yes Anchors subjected to sustained tension: Not applicable Ductility section for tension: 17.2.3.4.3 (c) is satisfied Ductility section for shear: 17.2.3.5.3 (b) is satisfied Oo factor: not set Apply entire shear load at front row: No Anchors only resisting wind and/or seismic loads: Yes Strength level loads: Nua [lb]: 3870 Vuax [lb]: 0 Way [lb]: 0 <Figure 1> 0 lb Company: Date: 11/9/2021 Engineer: Page: 2/5 Project: Address: Phone: E-mail: Z 3870 lb 0 lb Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Anchor Designer"' Software Version 2.7.6990.8 <Figure 2> Company: Date: 11 /9/2021 Engineer: Page: 3/5 Project: Address: Phone: E-mail: Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Anchor DesignerT"' Software Version 2.7.6990.8 Company: Date: 11/9/2021 Engineer: Page: 4/5 Project: Address: Phone: E-mail: 3. Resulting Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, Nu (lb) Vu (lb) Way (Ib) 1(Vuax)2+(Vuay)2 (lb) 1 3870.0 0.0 0.0 0.0 Sum 3870.0 0.0 Maximum concrete compression strain (%o): 0.00 Maximum concrete compression stress (psi): 0 Resultant tension force (lb): 3870 Resultant compression force (lb): 0 Eccentricity of resultant tension forces in x-axis, e'Nx (inch): 0.00 Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00 4. Steel Strength of Anchor in Tension (Sec. 17.4.1) Nsa (lb) 0 ON. (lb) 13100 0.75 9825 5. Concrete Breakout Strength of Anchor in Tension (Sec. 17.4.2) Nb = kc,i fchet'.5 (Eq. 17.4.2.2a) kc fc (psi) het (in) Nb (Ib) 0.0 24.0 1.00 2500 4.000 9600 0.750Ncb = 0.750 (ANc/ANco)7ed,NYo,NYop,NNb (Sec. 17.3.1 & Eq. 17.4.2.1a) ANc (in') ANco (in' ca,.m (in) V'ed,N PC,N V'cp,N 0.0 Nb (Ib) 0 0.750Ncb (lb) 144.00 144.00 8.00 1.000 1.00 1.000 9600 6. Pullout Strength of Anchor in Tension (Sec. 17.4.3) 0.750Npn = 0.750Vc,PNp = 0.750Vc,P8Abrgfc (Sec. 17.3.1, Eq. 17.4.3.1 & 17.4.3.4) V'c,P Abrg (in2) fc (psi) 0 0.750Np, (lb) 1.0 0.67 2500 0.70 7046 0.75 5400 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Anchor Designer"' Software Version 2.7.6990.8 IN Company: Date: 11/9/2021 Engineer: Page: 5/5 Project: Address: Phone: E-mail: 11. Results 11. Interaction of Tensile and Shear Forces (Sec. D.7)? Tension Factored Load, Nua (lb) Design Strength, oNn (lb) Ratio Status Steel 3870 9825 0.39 Pass Concrete breakout 3870 5400 0.72 Pass (Governs) Pullout 3870 7046 0.55 Pass 5/8" 0 Heavy Hex Bolt, F1554 Gr. 36 with hef = 4.000 inch meets the selected design criteria. 12. Warnings - Per designer input, ductility requirements for tension have been determined to be satisfied — designer to verify. - Per designer input, ductility requirements for shear have been determined to be satisfied — designer to verify. - Designer must exercise own judgement to determine if this design is suitable. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com