REVIEWED BLD2022-0132+Energy_Calculations+2.1.2022_4.30.49_PM+2655458BLD2022-0132 RECEIVED simple Heating system size: wasnington state This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manua s J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling IooOE LO M EDMONDS ELOPMENT SERVI( DEPARTMENT Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information Emily Tomkinson Kueger Krafting 22903 76th Ave. W .116 Greg Krueger Edmonds, WA 98026 206 819 2710 Heating System Type: All Other systems Q Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions" REVIEWED Design Temperature BY Instructions Design Temperature Difference (AT) CIT2V OF EDMONDS Edmonds OT = Indoor (70 degrees) - Outdoor Design Temp Ar-- of building Conditioned Floor Area instrucuons Conditioned Floor Area (sq ft) 2,033 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.0 16,264 Glazing and Doors U-Factor X Area = UA Instructions U-0.22 . 0.220 254 55.88 Skylights U-Factor X Area = UA Instructions 0.50 Insulation Attic U-Factor X Area = UA Instructions R-49 • 0.026 2,033 52.86 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions Select R-Value • No selection F --- Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions R-211ntermediate • 0.056 1,712 95.87 Floors U-Factor X Area UA Instructions 0.025 2,033 50.83 R-38 • Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions Select R-value L• No selection --- Slab Below Grade (see Figure 1) F-Factor X Length UA Instructions Select conditioning . No selection --- Slab on Grade (see Figure 1) F-Factor X Length UA Instructions Select R-Value No selection Location of Ducts Instructions Duct Leakage Coefficient Unconditioned Space • 1.10 Sum of UA 255.44 Envelope Heat Load 11,750 Btu/Hour Figure 1. Sum of UA x AT Air Leakage Heat Load 8,080 Btu / Hour Volume x 0.6 x AT x 0.018 Above Grade Building Design Heat Load 19,830 Btu/Hour Air leakage + envelope heat loss Building and Duct Heat Load 21,813 Btu/Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 30,538 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump (07/01/13)