Loading...
APPROVED PLN ENG RESUB3 BLD2022-1081+Site_Plan+1.9.2023_4.02.26_PM+3305493I I I I I I I I I 25' - 0'1 B.S.— o � 0 C0 i I 1 EXT. 6' SAN. SEWEF 6_ EASEMENT _ (A.F. NO. 2221358) 1 SEWER LINE REFE �= SEWER PERMIT DA N 10/29/1971 (SEE 2/A I 8 ° 10' 3111 W -- 139.891 I I � REFER TO SHEET A1.5 FOR DOWNSPOUT PLAN. PLAN SNIP PROVIDED BELOW. )l - d,00..,pw. ❑ _______ __t._ ____ _______ -_ ' Mxk �� IN) , b I b9 IEl erecna,ge Boa erih in a .qw, doo. io a.mo IElowmp,ine amo lip MIY�nWP� I IEI —P■■ CAUTION: SETTING OUT OF SETBACK LINE FROM PROPERTY LINE TO BE VERIFIED BY R TO SURVEYOR TED 0.0) i PROPERTY LINE RESOURCE FROM: PLATMAP DATED 5-19-88 I I I Demo (E) tree 88 O 1 01 31 1 W 20existing drain location for existing shared driveway . 061 drainage discharge NEW SS C.O. TO GRADE, \ Demo (E) tree FENCE PROPERTY LINE FIELD VERIFY EXACT \ LOCATION, LOCATED WITHIN O catch basin drain 2' OF THE STRUCTURE O °; -d `southward to the main C) \ . r ,° d • ° - ° storm line on172n St. SW 9' - 9 7/8" A 43' - 2 1/2" existing driveway and its ° d a existing drainages stem too. — a ° sErBAc d undisturbed ndisturbed a a •, • It a 1_1a 4 - ROOF LINE -�/ - - - - - (N) Garage B.S. Q f F- - - - - - - - - - extension on °d °a•� 20' - 0 7/8"a d 60 BLD LINE - i existing garage '�" ' •„ ' •° " ° = `n \ — — 190 SF Exist. 20 roadway easement (A.F. No. 2208811) \ I Remove(E)tree Q ° „ ' -= (N) Kitchen \ °"'Exist. 10' electrical distance easement (A.F. No. 2212978) -- extension on (E) - ° -- deck \ UNDERGROUND a H a'` a °u. °'. • �� I a� 493 SF \ ELECTRICAL PANEL ° _ . ;° 4 _ al a� -_-_ (N) Level 1 ' • _ ° Deck & \ ELECTRICAL LINE °d ,� a -°,j M° stair ° a° 256 SF — -- \ I= d ° add - - a d' d ° I _ - - •'l o- - ° d �.. Remove (E) tree - - - — \ NEW SS C.O. TO GRADE, — ih \ FIELD VERIFY EXACT d - LOCATION, LOCATED WITHIN ° ° (N) basement \ 2' OF THE STRUCTURE ° ---------- - ---- ---- , -- I I I I I I +wE�r mia w. I I O I I V / I I 4 I ■ � � �, I � MI Ma 9Epyn, O (�j/�) 0V I I.I�.�,los�l J w _ r— L III I„ I I � ICI I;I Ili fI -- --- Li - I; -- I ICI I„ 80 I TYPE OF AREA O I Existing (roofs, hard surfaces) - estimated, referred to approved site O I plan dated 01/15/2009 & proposed grading plan dated 07/09/1996 (resourced from City of Edmonds.): ZI Driveway 4,243 SF I Building 3,375 SF Patio 1,442 SF + 2,845 SF Pond 614 SF ITotal 12,519 SF New / Replace Kitchen 3 SF 49II IDeck 256 S Garage 190 SF Total I 939 SF I I I I II I C)F— I 75 rn 66 co CV O N rn 1 AS PROVIDED ON SHEET A6.2 extension 190 SF -00 (E) Concrete pavement remain untouched co (E Level 1 Deck 102 SF r JREFER TO SEWER PERMIT <. _-a. DATED 10/29/1971 (SEE 2/A0.0) I d. \ as � a ,_ •a° - ' " :4•°I =A, PROPERTY PARCEL # 00513100012222 7527 172nd St SW, Edmonds, WA 98026-5123 ° E Concretedrivewa - O driveway ° remain untouched 8_a a 00 NET SITE AREA: 20,039 SF ° ;"a - -°a: r N I"a • PROPERTY LINE RESOURCE ADJACENT PROPERTY FROM: PLATMAP DATED ° �° # 00513100012209 5-19-88 (E) Building remain untouched d9° Basement: 1,900 SF I Level 1: 1,779 SF ° °- Garage: 496 SF Total (E) GFA: 4,175 SF • "I d a- • `' - I. - 4 ° a CN °d , as14 a �- - - ° al =a a •j•.,_°_ If ENGINEERING DIVISION C APPROVED AS NOTED 43' - 3 1/2" d ° - �/ 1/25/2023 ° d°; PROPOSED NEW/REPLACED _ .°.n' _°.f ; IMPERVIOUS AREA IS LESS THAN dd 0 b I °JQ 2000sf AND THEREFORE DOES (E) Concrete driveway ° . d ° ° FF d_ ° remain untouched da- ° (' ' _ _ - a _ _;d _ ° ° NOT TRIGGER STORMWATER '•.d MANAGEMENT. (E) Softscape and WATER LINE ° ORIGINAL HOUSE BUILT IN 1972. _ -• **ESTIMATED GAS AND -�". '°_ - ° a trees to be remained WATER LINE PROVIDED BY — GAS LINE OWNER, VERIFY IN FIELD ° NO KNOWN STORMWATER ° BY SERVICE LOCATOR MANAGEMENT SYSTEM ON -SITE. • d .° d d REFER TO SHEET A1.5 FOR a DOWNSPOUT PLAN �= . ° "Nothing in this permit approval process shall be interpreted as ° ° d <°'_ °n OWNER/CONTRACTOR IS RESPONSIBLE FOR allowingor permitting the maintenance of an current) existing p g y y g ° EROSION CONTROL AND DRAINAGE illegal, nonconforming or unpermitted building, structure or site _ °= - REFER TO SEPARATE TESC PLAN ° g a� condition which is outside the scope of the permit application, a ° °° _ ° ° _ a d _ < a regardless of whether such building, structure or condition is °-d ° _ n shown on the site plan or drawing. Such building, structure or _ d ° ° ., - I _ f _ OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING (E) Softscape and Q - '- a-= d ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY condition may be the subject of a separate enforcement action." trees to be remained,, - d° °4 ; a d ' I ° a9• ° - j� ' UTILITIES MAY REQUIRE A SEPERATE PERMIT. • . -- - - .e- - - d -° - d ° , as I-°• -. ° •"_f d° N 8801 ° °I W 14 31 8.6 8 — — — — — — — — — — — — — — — STORM LINE PER SNOHOMISH COUNTY ------------ SITE PLAN 1/8" = 1'-011 172 ND ST SW - 10' 31 W 20.0 6 / / BLOWOFFS & WATER =— MAINS PER / SNOHOMISH COUNTY / / SITE COVERAGE AND BUILDING HEIGHT STRUCTURAL MAXIMUM LOT COVERAGE BY STRUCTURES = LOT COVERAGE 35% (ECDC 16.20.030) TOTAL LOT SIZE 0.54 ACRE (23,522.4 SF) PER SNOHOMISH COUNTY SEE NET SITE AREA = 20.039 SF, PER PLATMAP DATED CALCULATION 5-19-88 DIAGRAMS ON 1 /A6.1 & 2/A6.1 BUILDING HEIGHT (ECDC 16.20.030) SEE CALCULATION DIAGRAMS ON 7/A6.1 ALLOWED MAX. LOT COVERAGE = 35% x 20,039 SF= 7,013,65 SF EXISTING: 3,180.5 SF PROPOSED: 3,132.5 SF + 465 SF (ADDITION) = 3.588.5 SF (17%) HEIGHT CALCULATION (ESTIMATED, RESOURCE FROM: SNOHOMISH COUNTY IMAP) FROM SITE PLAN (A0.0) A: 255.22' B: 261.28' C: 262.85' 253.57' D: TOTAL: 1,032.92' AVE. GRADE: 1,032.92'/4 = 258.23' 25 FT ALLOWED; MAX.: 283.23' PROPOSED: 2750 27/32" A nr_ A n A In Er r-M r% RA A 0% i nrI NEW PLUS TYPE OF AREA REPLACED IMPERVIOUS Existing (roofs, hard surfaces) - estimated, referred to SURFACE approved site plan dated 01/15/2009 & proposed grading plan dated 07/09/1996 (resourced from City of Edmonds.): SEE CALCULATION DIAGRAMS ON 2,3/A6.2 Types of Area Square footage Existing Impervious 12,519 SF New/Replaced 939 SF New Impervious 12,718 SF APPLICAON -- -�--� �.p� for LYN�iOYJOD uNi I The City off"6 onTSIDE SEWER PERMIT �%g f `.rs1L. NEW CONSTRUCTION R-' REPAIRS ❑ ' $S No. .0.....Y........1. OWNER Hf%radL...r1.1 /tt.�.N../...._ ...15.:........_.. !. �,. .'...................... CONTRACTOR ... /J�.�7.....�ll %3 �a �iC :ta... .Se.r• ... PERMIT No .. 9,51 O 7s� 7 _ AT ADDRESS ..?3_�.?........_.-�_7: .._u�.'_S •_ ......................_....._. LEGAL DESCRIPTION: LOT No..S. Cz...._!'!".!.!K.N.�R.... w=tc No........_................. ........ QT{6ET NAME OF ADDITION .................................................................... ............................ _........ ........ -_................. Ivr.Te/` fut`�2r �gcc.a. ti�o, aa3-o73�0 let I kccQ.-J 0v 7 O10 .303-0 cc� R do so 0 7527- 1 72 mo S ,S cIo rb�• a&5 �Ee x.T ao. 4os I -1 S2-9 - I�Z� S, •4c,a oa: ,o-la•-il I!CC6°PT 1� �y �t R�C6 IP 1 Ffo. 3a9 0 -- .' Approves: nDATE ...�.�+�.�.��..��....... By�.� ......... .................. &-m S�Aa Towel- �xmIT s. « 7.29 7Z s �, , . I l I , _ t 4- -L q j I .I . 1 - T-ap'I . !. '�?7 •:. Y0 II-a-.ff�..f� i ..h'!'I-.•i- .;�8 frKc�y. �B�/�irtir'! .I .; I j r i �G.TO _ i I I I .1 1• ; I j _i .I ! �_ ., i. .t i �. I _+_ ! .�. yvs,/ ! 1.....i4 f.i I 1 j I I I I .� i k t- a EXISTING UTILITIES PLANS 1'-091 k1 5ft2 Studio Architects 5TT 2 2625 Northup Way, Suite 100, Bellevue, WA 98004 info@5ft2studio.com www.5ft2studio.com 425.287.1567 20120172 REGISTERED ARCHITECT PEIK LI PAN v STATE OF WASHIN TON 08.2.2022 7527 Edmonds 7527 172nd St SW, Edmonds, WA 98026-5123 Building Permit B LD2022-1081 RS Zone �� Corner N Flag Y." Setbacks: Required Actual Front 2_5., Sides__1:01 - -------- Rear 1_0___; ---- - 25 Other ----------- Height ' ---------- NO. DESCRIPTION DATE 1 Revision 1 10/23/2022 2 Revision 2 12/06/2022 3 Revision 3 01/04/2023 RESUB Jan 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-1081 APPROVED BY PLANNING Jan 09 2023 DATE: 08/102022 SITE PLAN ENG2022-0523 - SEWER PERMIT AO. 1