Loading...
APPROVED BLD RESUB1 BLD2023-0028+Architectural_Plan+4.15.2023_1.55.17_PM+34852942018 Washington State Energy Code Res,dentio, Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Each dwelling unit in a residential building shall comply with sufficient options from Table R406 2 (fuel normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of credits. To claim this credit, the building permit drawings shall specify the option selected and the maximum tested building air leakage, and show the qualifying ventilation system and its control sequence of operation. 1 Small Dwelling Unit: 3 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than S00 sf of heated floor area but less than 1,S00 sf 2. Medium Dwelling Unit: 6 credits All dwelling units that are not included in 01 or 03 3. large Dwelling Unit: 7 credits Dwelling units exceeding 5.000 sf of conditioned floor area 4 Additions less than S00 square feet♦ 1.S credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table, review the details in Table 406.3 (Swig* Family), on page 4 Summary of Table R406.2 Heating Fuel Normalization Descriptions Credits - select ONE User Notes Options heating option 1 Combustion heating minimum NAECA 00 xl 2 Heat pump 10 ❑ 3 Electric resistance heat only - furnace or zonal -1.0 ❑ 4 DHP with zonal electric resistance per option 3 4 0.5 -1 S All other heating systems -1.0 I Energy Credits - select ONE Energy Credit Option Descriptions energy option from each OptlOns category 1.1 EffKient Building Envelop,- 05 IX 1.2 Efficient Building Envelope 10 1.3 Efficient Building Envelope 05 U 1.4 Efficient Building Envelope 10 I 1 1.5 Efficient Building Envelope 20 I - 1.6 Efficient Building Envelope 30 I 1 1.7 Efficient Budding Envelope 0 5 l l 2.2 Air leakage Control and Efficient Ventilation 05 [� 2.2 Aw Leakage Control and EffKient Ventilation 10 I I 2.3 Aw Leakage Control and EffKient Ventilation is Ll 2.4 Air leakage Control and EffKient Ventilation 20 3.1' High EffKiency HVAC 10 1 3.2 High EffKiency HVAC 10 7 3.3' NO EffKiency HVAC is 3.4 High EffKiency HVAC 1 5 LI 3.5 High EffKiency HVAC is ❑ 3.6• High EffKiency HVAC ❑ 20 ❑ 4.1 High EffKiency HVAC Distribution System 05 ❑ 4.2 High EffKiency HVAC Distribution System 10 ❑ 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New b Additions (effective February 1. 2021) Summary of Table R406.2 (coat_) Energy Credits - select ONE Energy Credit Option Descriptions (coat ► energy option from User Notes Options each category S.V Efficient Water Heating 0.5 1 5.2 Efficient Water Heating 0.5 , S.3 EffKient Water Heating 1.0 iT S.4 EffKient Water Heating 1.S ❑ 5.5 Efficient Water Heating 2.0 ❑ 5.6 Efficient Water Heating 13 IS ❑ 6. le Renewable Electric Energy (3 credits max; 1.0 Q 7.1 Appliance Package O.S ❑ Toro CredrrY [ 1.5 ��C�F. a An atterngtiye heating source sized at a maximum of 0.5 Wjtf leaurvaknt► of heated floor area a S00 W Window, Skylight and Door Schedule Ref U-factc Exempt Swinging Door (24 sq. ft. max Exempt Glazed Fenestration (15 sq. ft. max ) Vertical Fenestration (Windows and doors) Component Descrimion Re* •,� Oining Room: Vinyl Double Hung 0-24 Bedroom #3: Vinyl Casement 0.24 Bedroom #4: Vinyl Casement 0-24 Bathroom: Vinyl Casement 0.24 Master Bath: Casement 0.24 Primary Bathroom: VI Casement 0.24 Prinmy Bathroom: Vinyl CasemeM 0.24 Primary Bedroom: ~ Casetnerd 0-24 Pirmary Bedroom: VW SWeir 10.24 Bedroom 02 0-24 Ex. Great room: VN Slider 0.24 Kitchen: Vmyl CaserneM 0-24 Overhead Glazing (Skylights) Component COFW&CI ln&vr dtkV7 Width Height Ot Feet Feet width Height Qt Feet i Feet =©E©E =ME== =©E©E =ME== ==EMS Sum of Vertical Fenestration Area and UA Vertical Fenestration Area Weighted U = UA/Area Width Height Jt Feet i Feet Sum of Overhead Glazing Area and UA Overhead Glazing Area Weighted U = UA.,Area Total Sum of Fenestration Area and UA (for heating system sizing calculations) Area UA 0.01 000 0.01 0 00 Area UA 30.0 7.20 28.0 6.72 50.0 1200 7.5 180 9.0 216 4.0 096 7.5 180 30.0 720 40.0 960 20.0 480 66.7 1600 26.3 630 0.0 000 0.0 0001 318.9 7654 0241 Aran IIA 1111111MIN11101 11111101 rt� rt� rt� rt� 0.0 000 0001 318.9 ]6 54 Alterations Worksheet - 2018 Washington State Energy Code Nrolect lntormatron contact Informavor The WSEC requirements for alterations are located in Chapter 5 of the code text. Alterations (remodels) do not need to obtain energy credits from Table R406.3 Additions must meet the requirements for new construction. This Includes noncondit►oned space bei altered to become conditioned space. Will the wall cavities be exposed? X Yes r No If yes: Exposed wall cavities must be insulated - - 2 X 4 wall studs require R-15 insulation 3 00 2 X 6 wall studs require R-21 Insulation 3 eq zlzcn sc. sw 212cn sc. sw r WIII the roof ceiling framing cavities or attic be exposed? XYes No a°�a 213th St. SW If yes: Exposed rooficeiling assemblies must be Insulated - Vaulted ceilings: Insulate to the full depth of the framing member while allowing for the minimum 1" ventilated spac. Flat ceilings WIII the floor framing cavities be exposed? P Install R49 insulation or what the attic space can accommodate based on the roof pitch Yes XNo If yes: Exposed floor cavities must be insulated to R-30 Are the windows and/or doors being replaced? X Yes No ti -ludes both window or door and frames) If yes: New windows and doors must have an area weighted average U-factor of <_0 3C WIII the heating or cooling system be replaced? X Yes If yes: New equipment must meet current requirements and ducts need to be tested Will the hot water system be altered? Yes X No If yes: New water heating equipment must meet current code requirements Are more than 50% of the light fixtures being changed? jl� Yes No If yes: 90% of all lamps must be high efficacy (LED or CFL) The following documentation shall be available on = site for the building inspector: ■ ❑ COE APPROVED ARCHITECTURAL PLAN SET ■ X❑ COE APPROVED STRUCTURAL PLAN SET ❑ COE REVIEWED CALCULATION PACKET ■ ❑ ENERGY CREDIT WORKSHEET - ■ ❑ SITE PLAN ■ ❑ CIVIL PLAN ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ■ ti..........■.■.■.■...........................■.■ i ■ Special inspections are required for this project. I j 1. Structural Epoxy 12. Bolting in concrete I City Of Edmonds Building Department Work ADDITION/REMODEL Address 8023 2115TH PL SW Owner JOSEPH Approved Date 5/31/2023 Building Official "coma mL#L W. W v4tkezxe Permit Number BLD2023-0028 REVISIONS DATE - PAGES - CHANGES REV1 REV2 REV3 REV4 REV5 APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES ■ ■A separate plumbing permit is required for this project. Please obtain a plumbing permit from I ■the City of Edmonds. 1 A 214th PI. SW VI 3 Qj < a ro 214th Pi. SW D f 1423 215th PI SW 216th St. SW 218th St. SW 218cn St. SW w 3 C a 3 > a C L G o 00 220tn St. SW 220cn St. SW INITY TABLE OF. CONTENTS. COVER SHEET: Pi VICINITY MAP, PROJECT INFO., ENERGY WORKSHEETS P2 PLOT PLAN ARCHITECTURAL: Al ELEVATIONS A21ST FLOOR A2.1 EX. 1ST FLOOR PLAN A3 DETAILS A4 CROSS SECTION STRUCTURAL DRAWINGS: S1.1-4.1 STRUCTURAL PLAN PROTECT INF 1. SIESTA GLEN BLK 000 D-00 - LOT 3 2. PARCEL NUMBER 00573300000300 3. VICINITY MAP (SEE THIS PAGE). 4. REMODELADDITION: 8023 215TH PL SW EDMONDS, WA. 98026 5. OWNER: SARAH & IAN JOSEPH 6. STRUCTURAL ENGINEER: MIKE MAECHLER C G ENGINEERING. MIKEM@CGENGINEERING.COM 7. 1ST FLOOR = EX. LIV: 1,232.02SQ. FT., EX. GARAGAE 290.48 SQTT. PROPOSED LIVING ADDITION: 499.25 SQ. FT., PROPOSED GARAGE ADDITION 82.50 SQ. FT., PROPOSED PORCH: 94.52. 9. WIND EXPOSURE B, SEISMIC ZONE D, SOIL: 2000PSF. 10. OCCUPANCY: GROUP R, DIVISION 3. 11. GLAZING U VALUE VERTICAL = .30U VALUE OR BETTER, OVERHEAD U VALUE =.50, CEILING R VALUE=49, WALL R VALUE=21 FLOOR INSULATION R-30, SLAB R VALUE=R-10 MANUAL WINDOW VENTS W / EXHAUST FAN OR TIMER IN LAUNDRY ROOM 12. THIS BUILDING IS TYPE VB. 13. COMPLY WITH IBC 2018', IRC 2018', IMC 2018', IFC 2018', UPC 2018, WSEC 2018. 14. ADDRESS NUMBERS (6" HEIGHT ON APPR. CONTRASTING BACKGROUND) SHALL BE POSTED PLAINLY VISIBLE & LEGIBLE FROM STREET OR ROAD FRONTING PROPERTY. 15. PROVIDE FIRE ESTINGUISHERS PER IFC STANDARD 10-1. R E S U B Apr 17 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT e MAX HEIGHT: 468.98' ACTUAL HT: 464.31' N O 11 H F0 Z_ J_ Lu U CV Lu J J FIRST FLORR: AVE GRADE: 445.90' MAX HEIGHT: 468.98' ACTUAL HT: 464.51' N 19 nil SCALE: 1/4" =1'-O" Co SCALE: 1/4" =1'-O" .. < O rr^^Lu O VJ VJ _o O Z O J � N J � O � Q FIRST FLORR: 445.34' _ LA5: 444.84' N --------------------------------------------------------------------------------------------------------------------------------------------------------------------- N Cl AVEGRADE: 443.90' � �-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�--�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�-�--�-�-�-�-�-�-�-�-�-�-�-�-�--�-�-�-�- - - U c\1 Z WEST ELEVATION O 00 � � o w SCALE: 1/4" =1'-O" SCALE: 1/4" =1'-O" ROOF PITCH: 8/12 MAIN ROOF OVERHANGS: °AAA: RESUB GABLES: 2X12 W/ A�r 17 2023 BELLY BAND: 2X12 CITY OFEDMONDS DEVELOPMENT SERVICE DEPARTMENT 12.19.22 REVISIONS: 1.13.23 4.3.23 IPRINTED: I 4.3.23 t\ im 8'5-1/2" I I I I I I I I I /2" 4� KITCHEN 15'3" 33, O LLU10i N ILD I I � I I I I I . m 14'9-1/2" 13' 3' 1 6'6" ----------------------------------------- I I II I III I MA5TER I'IBEDI200M I I LL I I z I I J I N w cQ J II j I I I I I I I I I I I I I '11-1/2" 119" 4' 27-1/2" 44" MAX SILL HT I IF 2'6" = LE I _ --------------- i 2668 10'4" �t 50 CFM 1--I 18'6-1/2" ---------------------- - N BEDROOM #2 ° MASTER BAT O N o \\ O O � GKEATKOOM rk ----- ------------------------------------------- VAULTED CEILING ----- ----7 -------------------------------------------- ---------- ' N Fo L - -r --------------------------------------- 2668 1 'j. II 20 INUTE E N GL0 G D EX. GAS FURNACE ANTKY �j � flINM--ROOvl-----------------' ENTRY HEAT D K PER R314.2.1 CREDIT 5.3 1 CREDIT: O GY 5TAR RATED N AS HO TLIK TANK O 506 DH MIN UEF OF; 1 BOLLARD PER M130 .1 N li N GARAGE PROPOSED PORCH _ I II � 16080 OVERHEAD DOOR LLo z o - o� --------------------------------- II LL C1i I I I LL � Q U I I I I I I I 419" 713" I I I I 216" 10, 10, 14'6" 5'6" 14'6" 20' r- I -------------------- ---- - 1L------------- a '---�--------- ------------- 4----a-- -- - 5068 BY PA55-------------------- N ` In U z W m 06 0 0 N m N o to L0 N° ° 5'9" nV r - 3'4�. ! 3'6" BATHROOM 3068 I III 1100 C WHOLE 1 I_______i HOU5 N VT.o. LAUNDRY ----------------------- t o CV � Q PEL)KOOM #5 O m o � N � 44" MAX 51LL HEIG T 7640 I I ----------------------------- 11'2" 2' 7' 7' 50 CFM I (9 I 4668 5 1 ER 1/211 31111 21,911 III L. II O A o 1 EPROOM #4 O I O ----- 2636 WINDOW IN ATTIC 10" 8'6" 44" MAX SILL HEIGHTIN �'�1 12' 12' 3'6" N N SYMBOL5 0 INDICATES 2X6 @ 16" O.C. STUD WALL W/ R-21 (EXT TYPE) 0 INDICATES EXISTING WALL INDICATES NEW 2X4 C@ 16" O.C. - INDICATES WALL TO BE REMOVED INDICATES EX. 2X4 WALL O 120V 5MK DET W/BATT BACKUP CARBON MONOXIDE DETECTOR PER IRC 315 I Ix 22"X30" ATTIC ACCE55 (30" MIN. VERT. CLEAR. WEATHERSTRIP & IN5UL. TO R-49 PER W5EC 502.1.4.4 • CFM FAN COMPLY WITH M1507, 2015 IRC • RECESSED LIGHTING TO BE IC RATED •MIN. HEADROOM CLEARANCE OF 7'-6" 15 REQ'D IN ALL HABITAL SPACES, & 7-0" 15 REQ'D ELSEWHERE •PROVIDE ONE OPENADLE ESCAPE WINDOW IN BASEMENT & IN EACH SLEEPING ROOM MEETING ALL THE FOLLOWING REQUIREMENTS: 1. AN OPENAPLE AREA OF NOT LE55 THEN 5.7 5Q.FT. 2. A MIN. CLEAR HEIGHT OF 24" 3. A MIN. CLEAR WIDTH OF 20" 4. FINISHED SILL HEIGHT OF NOT MORE THAN 44" ABOVE THE FINISH FLOOR. 5. ALL WINDOWS TO INCLUDE FRESH AIR VENTS OR METERED FRESH AIR SUPPLY @ FURNACE 6. ALL WINDOWS & DOOR5 HAVING ACCE55 TO EXTERIOR OR UNHEATED TO BE SEALED PER SEC. 502.4.3 (W5EC) STAIR NOTE5 *MAINTAIN REQ'D NO-HR STAIRS ENCLOU5URE5 & MIN 6'-&" HEADROOM @ STAIRS •STAIR BACKING FOR HANDRAIL •STAIR: RISE = 7.5" RUN =10" GARAGE NOTES (1HR CON5TRUCTIONI •5/8" GYP TYPE "X" 5HEETROCK REQ'D TO SEPARATE GARAGE FROM DWELLING •GAS VENTING IN UNCONDITIONED SPACE TO 5E TYPE 5 OF L VENT MATERIAL • SOURCE OF IGNITION OF GAS APPLIANCES MUST BE RAISED A MIN. OF 18" ABOVE FINISHED FLOOR IN GARAGEIMC ADDITIONAL PLUMBING REQUIREMENTS: •MAIN BUILDING SHUT-OFF REQ'D ON WATER SUPPLY LINE. •PRE55URE REDUCTION VALVE ON MAIN WATER SUPPLY LINE REQ'D BY CITY CODE •EXPANSION TANK REQ'D ON EA. HOT WATER TANK. •VENT HOT WATER TANK RELIEF VALVE DIRECTLY TO THE OUTSIDE •HOT WATER HEATER MUST 5E 5EI5MICALLY ANCHORED OR STRAPPED @ POINTS WITHIN THE UPPER 1/3 & LOWER 1/3 OF ITS VERTICAL DIMENSION. @ THE LOWER POINT, A MIN. DISTANCE OF 4" MUST BE MAINTAINED ABOVE THE CONTROLS W/ THE STRAPPING •1" AIRGAP REQ'D ON DI5HWAH5HER •ALL SHOWERS HEADS TO BE EQUIPPED W/ FLOW CONTROL DEVICE TO LIMIT FLOW TO 3 GPM •HOSE 13IB5 (EXT. FAUCETS) ARE REQ'D TO HAVE A PERMANENTLY AFFIXED ANTI -SIPHON DEVICE INSTALLED • SOAKER & JETTED TUBS SHALL BE INSTALLED & SUPPORTED PER THE MANUFACTURER'S INSTALLATION SPECIFICATIONS GARAGE WALL. IBC. FIREPLACE NOTES •'O' CLEARANCE FIREPLACE W/ DIRECT VENT •FACTORY BUILT FIREPLACE SHALL BE INSTALLED PER MAN. SPECS & SHALL HAVE APPROVAL LABEL ATTACHED •50' TYPE "X" GWB TO ROOF 5HEATING •FIREPLACE & STOVES MUST BE D.O.E. APPROVED & 5E TESTED. CERTIFIED & LABELED AS SUITABLE FOR USE DURING A FIRST STAGE BURN BAN •ALL FIREPLACE PROJECTIONS WITHIN 5' OF PROPERTY LINE MUST HAVE 1-HOUR RATED CONSTRUCTION COVER OVER OSB SHEATHING WITH DEN5GLA55 OR 51MILIAR FIRE -RATED GWB MATERIAL & THEN COVERED WITH HARDIE SIDING IRC R314.3 SMOKE DETECTOR5 REQUIRED THE ISSUANCE OF THIS PERMIT REQUIRES INNERCONNECTED SMOKE DETECTORS WITH BATTERY BACKUP IN THE FOLLOWING LOCATIONS: •IN EACH SLEEPING ROOM •OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS •ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS BUT NOT INCLUDING CRAWL 5PACE5 AND UNINHABITABLE ATTICS. IN DWELLINGS OR DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL 15 LE55 THAN ONE FULL STORY ELOW THE UPPER LEVEL. CRAWL 5PACE VENTILATION CRAWL 5PACE AREA = 499.25/150 = 5.53 SQ. FT. REQ'D VENTING 3.55 X 144 = 479.28 SQ. FT. KEQ'D PROVIDE (6) VENTS @ 87 5Q. IN. EA. = 522.00 SQ IN PROVIDED VENT SYMBOL - m VENTS LOCATED IN THE RIM PER IRC R408.2 *APPROVAL OF THIS FOUNDATION DE51GN 15 CONDITIONAL SUBJECT TO INSPECTION OF EXISTING 51TE CONDITIONS. •RETAINING WALLS MUST BE DESIGNED & CONSTRUCTED TO RE515T THE LATERAL PRESSURE OF THE RETAINED MATERIAL. •PROVI510N5 MUST BE MADE FOR THE CONTROL & DRAINAGE OF SURFACE WATER AROUND BUILDING ROOF VENTILATION CALCULATION 1731.27 5Q. FT. ROOF = 5.77 16.48 300 .35 3 6 VENTS REQ'D/NOTE: 50% OF VENTING SHALL OCCUR IN EAVES A5 BIRD CLOCKING AF50 ROOF VENTS TO BE USED ® BEARING WALL WOOD POST BELOW WOOD P05T ABOVE FLOOR J015T REFER TO PLAN FOR 51ZE ROOF PITCH: 8/12 MAIN ROOF OVERHANG: 6" MAIN 2' ON SHED OVER BEDROOM DENOTES OVERFRAME W12X6 SCALE:1/4" = 1'-0" EX. LIVING:1,252.02 SQ. FT. PROPOSED LIVING: 499.25 SQ. FT EXISTING GARAGE: 290.36 SQ. FT. PROPOSED GARAGE: 82.50 SQ. FT PROPOSED PORCH: 94.52 5Q. FT. RESUB Apr 17 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT N RE FOOTAGE PLA SCALE: 1/4" =1'-0" EX. LIVING: 1,232.02 5Q. FT. I'R01'05E1) LIVING: 499.25 50. FT EXISTING GARAGE: 290.36 5Q. FT. I'ROf'05EP GARAGE: 82.50 5Q. FT. I'R01'05ED PORCH: 94.52 5Q. FT. RESUB Apr 17 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TYPICAL ROOF CONSTRUCTION COMPOSITION ROOFING IN ACCORDANCE WITH IBC TABLE 1505.1,15 LB FELT 7/16" 05B ROOF DIAPHRAGM, U.N.O. 2X ENGINEERED TKU55 8d @ 6" O.C. 2X 50LID BLKG. W/ V�ENT� HOLES A5 REQ. 7/16" 0513 - FOR NAILING REFER TO 5HEAK WALL 5CHED. BLOW ATTIC INSULATION R - 49 FLAME SPREAD NOT TO EXCEED 25 AND SMOKE DEN5ITY NOT TO EXCEED 450 IN ATTIC U5E APPROVED INSULATION BAFFLE W/ 1" MIN. AIRSPACE ABOVE INSULATON H-1 OR EQUAL @ EACH TRU55 PER SHEARWALL 5CHD. 5/8" GWB, (2-LAYER 5/8" GWB IF 1-HOUR 5/8" GWB (2) 2X6 TOP FL TRUSS @ EXT. WALL TYP. 2X PLATE 16d@6"O.( 8d@6"O.0 L5L KIM JOI (2) KOW5 TC 1661 @ 6" 0.1 1/2"05B-F NAILING RE. SHEAR WAL TYP FLOOR CON5T. CARPET & 1/2" REBOND PAD 5/4" T&G 5UBFLOOR R-50 IN5U LATION TJI PER FRAMING PLAN 5/8" G.W.B. 2X JOI5T (2) 2X TOP PLATE K-21 INSULATION TYP NON -SW @ EXT. WALL ... ....... .... .... ........ ...................... .. ................ ......... . J J J J J HEAD WINDOW NAIL FLANGE JAMB i i J� 51LL i i (11) SIDING PER FLAN (10)15# FELT (9) HEAD FLASHING Z METAL @ EXPOSED WINDOW (4) 4" MIN M015TOP SELF -HEAL PAPER OR EQUAL SHEATHING (2) WINDOW FRAME (3) MOISTOP STICKY SELF -HEAL OR EQUAL BUTTED TO WINDOW AND 6" MIN OVER WINDOW FASTNER5 (7) 15# FELT (8) TRIM (11) SIDING PER PLAN (15) CAULK TOP EDGE LOWER FELT (1) 30# FELT PAPER, WRAP LAP UNDER WINDOW BEFORE WINDOW IN51ALLATION. (5) 30# FELT (6) 4" TAPE SEAL OVER FLANGE BUT NOT UNDER JAMB FELT (11) SIDING PER PLAN TYP, EXPLODED WINDOW FLASHING NUMBERS INDICATE ORDER OF APPLICATION N.S. RESUB Apr 17 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT MANUFACTURED ROOF TRU5E R-49 INSULATION IN ATTIC R-21 INSULATION@ EXTERIOR NEW WARM WALL R-50 INSULATION @ NEW FLOOR5 SCALE: 1/4" =1'-O" 1\ I✓ III✓VI-/ I I1-1I1I- EXTERIOR 2X4 EX. WALLS THAT HAVE BEEN EXF'05ED Z-30 INSULATION @ VEW FLOOR5 RESUB Apr 17 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT