APPROVED BLD RESUB2 BLD2023-0028+STRUCTURAL PLANS +5.18.2023_8.49.31_AM+3553215STRUCTURAL NOTES C G (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) CODE FOUNDATIONS: SPREAD FOOTINGS ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SOILS REPORT: REPORT NOT AVAILABLE AT TIME OF DESIGN SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION. SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. ALLOWABLE SOIL PRESSURE: 1500 PSF (ASSUMED; TO BE FIELD VERIFIED DURING CONSTRUCTION) DESIGN LOADS FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR 12" OF COMPACTED STRUCTURAL FILL AS REQUIRED AND AT LEAST 18" BELOW ADJACENT EXTERIOR GRADE. ANY FOOTING ELEVATIONS SHOWN IN THE DRAWINGS DEAD LOADS: REPRESENT MINIMUM DEPTHS AND ARE FOR BIDDING ONLY. ACTUAL FOOTING ELEVATIONS ARE SUBJECT TO SITE ROOF 15 PSF CONDITIONS AND MUST THEREFORE BE ESTABLISHED BY THE CONTRACTOR. FOOTINGS SHALL BE CENTERED BELOW FLOOR 40 PSF COLUMNS OR WALLS ABOVE, UNLESS NOTED OTHERWISE. LIVE LOADS: ROOF (SNOW LOAD) 25 PSF FLOOR 40 PSF (LIVE LOADS ARE REDUCED WHERE PERMISSIBLE PER IBC SECTION 1607.11). EARTHQUAKE LOADS: EQUIVALENT LATERAL FORCE PROCEDURE PER ASCE 7-16 SECTION 12.8. SITE CLASS D (DEFAULT) SHORT PERIOD SPECTRAL RESPONSE ACCEL (SS) 1.257 ONE SECOND SPECTRAL RESPONSE ACCEL (SI) 0.426 SHORT PERIOD DESIGN SPECTRAL RESPONSE ACCEL (SDS) 0.838 ONE SECOND DESIGN SPECTRAL RESPONSE ACCEL (SDI) 0.440 RISK CATEGORY II SEISMIC IMPORTANCE FACTOR (IF) 1.25 SEISMIC DESIGN CATEGORY D BASIC SEISMIC FORCE -RESISTING -SYSTEM CMU BEARING WALLS RESPONSE MODIFICATION FACTOR, (R) 5.0 REDUNDANCY FACTOR (p) 1.0 SEISMIC RESPONSE COEFFICIENT (CS) 0.126 W = TOTAL SEISMIC DEAD LOAD AS DEFINED PER ASCE 7-16 SECTION 12.7.2. BASE SHEAR (V), V = CSW = SIDSW 23.8 KIPS WIND LOADS: BASIC WIND SPEED (3 SECOND GUST) 100 MPH EXPOSURE C KzT 1.67 SEE PLANS FOR ADDITIONAL DESIGN LOADS. STATEMENT OF SPECIAL INSPECTIONS IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MAXIMUM PARTICLE DIAMETER OF THREE INCHES AND NO MORE THAN 10% FINES (PASSING THE #200 SIEVE). FILL AND BACKFILL MATERIAL SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE (12") INCHES IN LOOSE THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AS DETERMINED BY ASTM TEST METHOD D1557. EXCAVATIONS AND DRAINAGE INSTALLATION SHALL BE OBSERVED BY A SOILS ENGINEER RETAINED BY THE OWNER. IF EXCAVATION SHOWS SOIL CONDITIONS TO BE OTHER THAN THOSE ASSUMED ABOVE NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. CONCRETE ALL CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH CHAPTER 26 OF ACI 318 AND THE AMERICAN CONCRETE INSTITUTE'S SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301). ALL CONCRETE SHALL BE STONE -AGGREGATE CONCRETE HAVING A UNIT WEIGHT OF APPROXIMATELY 150 POUNDS PER CUBIC FOOT. CONCRETE STRENGTHS AT 28 DAYS (fc) AND MIX CRITERIA SHALL BE AS FOLLOWS: MAXIMUM MIN CEMENT TYPE OF CONSTRUCTION f'c* WATER/CEMENT CONTENT PER CUBIC MAXIMUM SHRINKAGE STRAIN RATIO YARD SLABS ON GRADE 3000 PSI 0.55 5 1/2 SACK N/A FOOTINGS 3000 PSI 0.55 5 1/2 SACK N/A WALLS 4000 PSI 0.45 5 1/2 SACK N/A THE MINIMUM AMOUNT OF CEMENT LISTED ABOVE MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH CHAPTER 26 OF ACI 318. MINIMUM LAPS AND EMBEDMENT UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE AS TABULATED BELOW: f'c = 3000 PSI DEVELOPMENT LENGTH LAP SPLICE BAR TENSION COMPRESSION TENSION COMPRESSION SIZE TOP BARS OTHER BARS ALL BARS TOP BARS OTHER BARS ALL BARS #3 22 17 9 28 22 12 #4 29 22 11 37 29 15 #5 36 28 14 47 36 19 #6 43 33 17 56 43 23 #7 63 48 20 81 63 27 #8 72 55 22 93 72 30 fc = 4000 PSI DEVELOPMENT LENGTH LAP SPLICE BAR TENSION COMPRESSION TENSION COMPRESSION SIZE TOP BARS OTHER BARS ALL BARS TOP BARS OTHER BARS ALL BARS #3 19 15 8 24 19 12 #4 25 19 10 33 25 15 #5 31 24 12 41 31 19 #6 37 29 15 49 37 23 #7 54 42 17 71 54 27 #8 62 1 48 19 81 1 62 1 30 NOTE: 1. ALL LENGTHS ARE IN INCHES. 2. ALL LAP SPLICES ARE CLASS B. 3. "TOP BARS" ARE HORIZONTAL REINFORCEMENT PLACED SUCH THAT MORE THAN 12 INCHES OF CONCRETE IS CAST IN THE MEMBER BELOW THE BAR. CONCRETE COVER ON REINFORCING CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" SPECIAL INSPECTIONS ARE REQUIRED AS INDICATED IN THE FOLLOWING TABLE. THE CONTRACTOR SHALL SUBMIT A ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR -ENTRAINED IN ACCORDANCE CONCRETE EXPOSED TO EARTH AND WEATHER: WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF WITH ACI 318 TABLE 19.3.3.1 FOR MODERATE EXPOSURE CLASS F1. #6 BARS AND LARGER 2" WORK IN ACCORDANCE WITH SECTION 1704.4 OF THE IBC. #5 BARS AND SMALLER 1 1/2" CONCRETE CONSTRUCTION - SPECIAL INSPECTION IS REQUIRED IN CONFORMANCE WITH IBC SECTION 1705.3 AND TABLE 1705.3. SPECIAL INSPECTION FOR THE ABOVE SYSTEMS SHALL BE AS INDICATED IN THE SPECIAL INSPECTION TABLE BELOW. STRUCTURAL OBSERVATION OF THE STRUCTURAL SYSTEM BY THE ENGINEER IS NOT REQUIRED. FREQUENCY AND DISTRIBUTION OF REPORTS - INSPECTION REPORTS SHALL BE PROVIDED FOR EACH DAY ON SITE BY SPECIAL INSPECTOR. STRUCTURAL OBSERVATION REPORTS SHALL BE PROVIDED AFTER EACH OBSERVATION. REPORTS SHALL BE DISTRIBUTED TO THE CONTRACTOR, ARCHITECT, ENGINEER AND BUILDING OFFICIAL. SPECIAL INSPECTION OPERATION CONT PERIODIC REMARKS CONCRETE ADHESIVE ANCHORS X IF USED EXPANSION ANCHORS X IF USED NOTE: ALL ITEMS MARKED WITH AN "X" SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17. SPECIAL INSPECTION SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE OWNER. THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL SHALL BE FURNISHED WITH COPIES OF ALL RESULTS. ANY INSPECTION FAILING TO MEET THE PROJECT SPECIFICATIONS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE DESIGN TEAM. SHOP DRAWINGS SHOP DRAWINGS FOR THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION: 1. PREMANUFACTURED WOOD TRUSSES SHOP DRAWINGS SHALL BE REVIEWED, REVISED AS REQUIRED FOR FIELD CONDITIONS, AND DATE STAMPED BY THE CONTRACTOR PRIOR TO REVIEW BY THE ENGINEER. CONTRACTOR SHALL PROVIDE (3) SETS OF SHOP DRAWINGS FOR ENGINEER'S REVIEW. ALLOW TWO WEEKS FOR SHOP DRAWING APPROVAL BY ENGINEER. ENGINEER'S SHOP DRAWING REVIEW IS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT AND CONTRACT DOCUMENTS. MARKINGS OR COMMENTS SHALL NOT BE CONSTRUED AS RELIEVING THE CONTRACTOR FROM COMPLIANCE WITH THE PROJECT PLANS AND SPECIFICATIONS. THE CONTRACTOR REMAINS RESPONSIBLE FOR DETAILS AND ACCURACY, FOR CONFORMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS, FOR SELECTING FABRICATION PROCESSES, FOR TECHNIQUES OF ASSEMBLY, AND FOR PERFORMING THE WORK IN A SAFE MANNER. ENGINEER'S SHOP DRAWING REVIEW OF STRUCTURAL COMPONENTS DESIGNED BY OTHERS IS FOR LOADS IMPOSED ON THE BASIC STRUCTURE. THE COMPONENT DESIGNER IS RESPONSIBLE FOR CODE CONFORMANCE AND ALL CONNECTIONS TO THE BASIC STRUCTURE. SHOP DRAWINGS SHALL INDICATE MAGNITUDE AND DIRECTION OF THE LOADS IMPOSED ON THE BASIC STRUCTURE AND SHALL BE STAMPED & SIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE SAME STATE AS THE PROJECT. FABRICATION SHALL BEGIN ONLY AFTER SHOP DRAWINGS BEARING THE STAMP AND SIGNATURE OF THE PROJECT ARCHITECT, ENGINEER OF RECORD, AND CONTRACTOR HAVE BEEN RECEIVED. DEFERRED APPROVAL ITEMS SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE ARCHITECT OR ENGINEER OF RECORD WHO SHALL REVIEW THEM AND INDICATE THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. DEFERRED SUBMITTALS SHALL BE STAMPED AND SIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE SAME STATE AS THE PROJECT. 1. PREMANUFACTURED WOOD TRUSSES *PROVIDE fc SPECIFIED IN TABLE FOR DURABILITY REQUIREMENTS. 2500 PSI CONCRETE MEETS STRENGTH REQUIREMENTS, THEREFORE SPECIAL INSPECTION IS NOT REQUIRED. CONCRETE GENERAL NOTES VERTICAL BARS SHALL START FROM TOP OF FOOTING. HORIZONTAL BARS SHALL START A DISTANCE OF 1/2 THE NORMAL BAR SPACING FROM TOP OF FOOTING AND TOP OF FRAMED SLABS. IN ADDITION, THERE SHALL BE A HORIZONTAL BAR AT A MAXIMUM OF 3" FROM TOP OF WALL AND BOTTOM OF FRAMED SLABS. PROVIDE CORNER BARS TO MATCH THE HORIZONTAL REINFORCING WITH TENSION LAP SPLICE AT EACH SIDE PER TABLE, OR BEND ONE SIDE OVER TO PROVIDE TENSION LAP. PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS ON GRADE TO BREAK UP SLAB INTO RECTANGULAR AREAS OF NOT MORE THAN 400 SQUARE FEET EACH. AREAS TO BE AS SQUARE AS PRACTICAL AND HAVE NO ACUTE ANGLES. JOINT LOCATIONS TO BE APPROVED BY THE ARCHITECT. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED BEYOND JOINT. SEE ARCHITECTURAL DRAWINGS AND MECHANICAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF OPENINGS IN CONCRETE WALLS, FLOORS AND ROOF. UNLESS INDICATED OTHERWISE, REINFORCE AROUND OPENINGS GREATER THAN 12" IN EITHER DIRECTION WITH (2) #5 EACH SIDE AND (1) #5 x 4'-0" DIAGONAL AT EACH CORNER. EXTEND BARS 2'-0" BEYOND EDGE OF OPENING. IF 2'-0" IS UNAVAILABLE, EXTEND AS FAR AS POSSIBLE AND HOOK. HOOK ALL REINFORCING INTERRUPTED BY OPENINGS. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE AND OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES. PROVIDE 3/4" CHAMFER AT ALL CORNERS EXCEPT AS NOTED. REINFORCING STEEL REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615, AND SHALL BE GRADE 60 (Fy = 60,000 PSI), UNLESS NOTED OTHERWISE. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615 MAY BE WELDED IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D1.4 ARE SUBMITTED. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. PROVIDE WELDED WIRE FABRIC IN SHEETS NOT ROLLS. LAP WELDED WIRE FABRIC 12" AT SIDES AND ENDS. REINFORCING STEEL SHALL BE DETAILED INCLUDING HOOKS AND BENDS IN ACCORDANCE WITH ACI SP-66 AND ACI 318, LATEST EDITIONS. UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE PER SCHEDULE. MECHANICAL SPLICING OF REINFORCING BARS, WHERE INDICATED ON THE DRAWINGS, SHALL BE BY AN ICBO APPROVED SYSTEM, SHALL DEVELOP 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR, AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET -SETTING EMBEDDED ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. REFER TO CHAPTER 25 OF ACI 318 FOR OTHER REINFORCING STEEL REQUIREMENTS. CONCRETE NOT EXPOSED TO EARTH OR WEATHER: SLABS, WALLS AND JOISTS 3/4" COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1 1/2" CONCRETE GENERAL NOTES VERTICAL BARS SHALL START FROM TOP OF FOOTING. HORIZONTAL BARS SHALL START A DISTANCE OF 1/2 THE NORMAL BAR SPACING FROM TOP OF FOOTING AND TOP OF FRAMED SLABS. IN ADDITION, THERE SHALL BE A HORIZONTAL BAR AT A MAXIMUM OF 3" FROM TOP OF WALL AND BOTTOM OF FRAMED SLABS. PROVIDE CORNER BARS TO MATCH THE HORIZONTAL REINFORCING WITH TENSION LAP SPLICE AT EACH SIDE PER TABLE, OR BEND ONE SIDE OVER TO PROVIDE TENSION LAP. PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS ON GRADE TO BREAK UP SLAB INTO RECTANGULAR AREAS OF NOT MORE THAN 400 SQUARE FEET EACH. AREAS TO BE AS SQUARE AS PRACTICAL AND HAVE NO ACUTE ANGLES. JOINT LOCATIONS TO BE APPROVED BY THE ARCHITECT. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED BEYOND JOINT. SEE ARCHITECTURAL DRAWINGS AND MECHANICAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF OPENINGS IN CONCRETE WALLS, FLOORS AND ROOF. UNLESS INDICATED OTHERWISE, REINFORCE AROUND OPENINGS GREATER THAN 12" IN EITHER DIRECTION WITH (2) #5 EACH SIDE AND (1) #5 x 4'-0" DIAGONAL AT EACH CORNER. EXTEND BARS 2'-0" BEYOND EDGE OF OPENING. IF 2'-0" IS UNAVAILABLE, EXTEND AS FAR AS POSSIBLE AND HOOK. HOOK ALL REINFORCING INTERRUPTED BY OPENINGS. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BYTHE STRUCTURAL ENGINEER. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE AND OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES. PROVIDE 3/4" CHAMFER AT ALL CORNERS EXCEPT AS NOTED. LUMBER ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fc (PSI) SLEEPERS DOUG-FIR STUD 700 - LIGHT FRAMING (STUDS) HEM -FIR STUD 675 800 2x JOISTS AND PLANKS HEM -FIR #2 850 - PLATES AND BLOCKING HEM -FIR #2 850 - 6x AND LARGER BEAMS AND STRINGERS DOUG-FIR #2 875 - 4x AND SMALLER BEAMS AND STRINGERS HEM -FIR #2 850 - ALL POSTS AND TIMBERS DOUG-FIR #1 1200 1000 REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1. NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: NAIL SHANK 0 MIN LENGTH 8d COMMON 0.1310 2 1/2" SHANK 10d COMMON 0.1480 3" SHANK 12d COMMON 0.1480 3 1/4" SHANK 16d COMMON 0.1620 3 1/2" SHANK 10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148" 0 x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE SHANK AND THREADED PORTIONS PER NDS 12.1.4.2. CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS, SCREWS, OR BOLTS IN EACH MEMBER. INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. GALVANIZATION UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED ACCORDING TO THE FOLLOWING TABLE: GALVANIZATION UNTREATED WOOD CCA-C SBX ACQ-C ACQ-D CBA-A CA-B OTHER BORATE ACZA OTHER PT WOOD G90 X X X G 185 X X X X X X HDG X X X X X X STT300 X X X X X X X X G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA HDG = HOT DIP GALVANIZED SST300 = TYPE 316L STAINLESS STEEL RATED SHEATHING RATED SHEATHING SHALL BE GRADE C-D INT-APA WITH EXTERIOR GLUE OR OSB SHEATHING WITH EXTERIOR GLUE IN CONFORMANCE WITH IBC STANDARD 2303.1.5. TIMBERSTRAND, MICROLLAM, AND PARALLAM MEMBERS FABRICATED IN CONFORMANCE WITH THE INTERNATIONAL CODE COUNCIL EVALUATION SERVICE (ICC-ES) REPORT NO. ESR-1387 OR CCMC REPORT NO. 12627-R, 08675-R, AND 11161-R. EACH MEMBER SHALL BE IDENTIFIED BY A STAMP INDICATING THE PRODUCT TYPE AND GRADE, ICC-ES OR CCMC REPORT NUMBER, MANUFACTURER'S NAME, PLANT NUMBER AND INDEPENDENT INSPECTION AGENCY'S LOGO. FABRICATOR SHALL BE CERTIFIED. MEMBERS SHALL MEET THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fv (PSI Fc (PSI) BEAMS & POSTS (d < 9 1/2") LSL 1.3E 1,700 425 1,835 RIMS & BEAMS (d >_ 9 1/2") LSL 1.55E 2,325 310 - BEAMS & POSTS LVL 2.0E 2,600 285 2,510 POSTS (d < 9 1/2") PSL 1.8E 2,400 190 2,500 BEAMS (d >_ 9 1/2") PSL 2.0E 2,900 290 - TIMBERSTRAND, MICROLLAM, AND UNTREATED PARALLAM MEMBERS ARE INTENDED FOR DRY -USE APPLICATIONS. UNLESS NOTED OTHERWISE, ENGINEERED WOOD BEAMS EXPOSED TO WEATHER SHALL BE TREATED PER MANUFACTURES RECOMMENDATIONS. GLUE -LAMINATED TIMBER GLUE -LAMINATED TIMBER SHALL BE DOUGLAS FIR, FABRICATED IN CONFORMANCE WITH ANSI/AITC STANDARD A190.1, LATEST EDITION. EACH MEMBER SHALL BEAR AN AITC IDENTIFICATION MARK AND SHALL BE ACCOMPANIED BY AN AITC CERTIFICATE OF CONFORMANCE. FABRICATOR SHALL BE CERTIFIED. MEMBERS SHALL BE OF THE FOLLOWING MINIMUM STANDARDS: SPAN COMBINATION Fb SIMPLE SPAN BEAMS 24F-V4 2400 PSI CANTILEVER OR MULTI -SPAN BEAMS 24F-V8 2400 PSI APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE ' The following documentation shall be available on site for the building inspector: '- x❑ COE APPROVED ARCHITECTURAL PLAN SET - ■ ❑ COE APPROVED STRUCTURAL PLAN SET ■ [:]COE REVIEWED CALCULATION PACKET - ■ ❑ ENERGY CREDIT WORKSHEET - ■ ❑ SITE PLAN ■ ❑ CIVIL PLAN ■ ■ ❑ - ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ■ ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 �1�THI' OF WAS$ iJsL��ti �IONAL i Q H H Z � CIO O m w � F- F- U LLI w w 0 a a N M LLI Q N Ln .H O 05/ 16/ 23 DESIGN: AL DRAWN: JEG CHECK: MTM JOB NO: 22294.10 DATE: 1 2/ 1 4/22 ■ Iy�C�1Py�:j RESUB May 18 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O N LEI o U op Z Cy) LEI o J a V) W = ICY ~ V)Ll 0 � Z La M O (n N :2 p 0 0 SHEET: S1.1 W O Z < LL D U D LL V) w z STRUCTURAL NOTES C G (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) TYPICAL FRAMING NOTES 1. BEARING WALL FRAMING 2x STUDS @ 16" OC FOR ALL SHEAR AND/OR BEARING WALLS UNO. REFER TO FRAMING PLAN NOTES FOR TYPICAL DOOR & WINDOW HEADERS NOT CALLED OUT ON THE PLANS. HEADERS SHALL BE SUPPORTED BY A MINIMUM OF (1) CRIPPLE AND (1) FULL HEIGHT STUD UNO. COLUMNS BELOW FLUSH MULTIPLE JOIST BEAMS SHALL BE EQUAL IN WIDTH TO THE BEAM. ALL COLUMNS NOT CALLED OUT OTHERWISE SHALL BE TWO STUDS. 2. WALL BASE PLATE ON CONCRETE WALL PLATES BEARING ON CONCRETE SHALL BE PRESSURE -TREATED. FOR ALL EXTERIOR AND INTERIOR WALLS, BOLT PLATES OR SILLS TO CONCRETE STEM WALLS OR THICKENED SLAB FOOTINGS WITH 5/8 INCH DIAMETER ANCHOR BOLTS WITH 7 INCH MINIMUM EMBEDMENT. PLACE AT 5-0" OC MAXIMUM FOR SHEAR WALLS, AND AT 6'-0" OC FOR BEARING WALLS AND OTHER PARTITIONS. USE MINIMUM OF TWO ANCHOR BOLTS PER SILL AND PLACE ONE WITHIN 12 INCHES OF END OF PLATES, TYPICAL UNLESS NOTED OR DETAILED OTHERWISE. REFER TO SHEAR WALL SCHEDULE. AT ALL SILL PLATE ANCHOR BOLTS, CONTRACTOR SHALL INSTALL 1/4" x 3" x 3" FLAT PLATE WASHERS. INTERIOR NON-STRUCTURAL WALLS MAY BE ANCHORED TO CONCRETE SLAB -ON -GRADE WITH 1/4" x 3" POWDER ACTUATED FASTENERS WITH 3/4" WASHERS AT 16" OC AND WITHIN 6" OF END OF PLATES. 3. ROOF AND FLOOR FRAMING PROVIDE 1 1/2" FULL DEPTH BLOCKING FOR JOISTS AND RAFTERS AT ALL SUPPORTS AND AT 8'-0" OC MAXIMUM UNO. INTERMEDIATE 8'-0" OC BLOCKING NOT REQ'D IF GWB CEILING IS INSTALLED DIRECTLY TO UNDERSIDE OF FRAMING. INSTALL DOUBLE JOISTS UNDER PARTITIONS EXTENDING ONE HALF OR MORE OF THE JOIST SPAN. PROVIDE TRUSS BLOCKING PANELS FOR ROOF TRUSSES AT SUPPORTS AND SHEAR WALLS, AND WHERE INDICATED ON PLANS AND DETAILS. 4. DIAPHRAGM NAILING ALL SHEAR WALLS, FLOOR AND ROOF DIAPHRAGM NAILINGS SHALL BE AS CALLED OUT ON SCHEDULES OR ON THE PLANS. EXTERIOR WALLS NOT INDICATED AS SHEAR WALLS SHALL BE SHEATHED AND NAILED TO SUPPORTING FRAMING WITH 8d NAILS AT 6" OC AT ALL PANEL EDGES AND 12" OC AT ALL INTERMEDIATE SUPPORTS. THE USE OF NAIL GUNS WILL BE APPROVED IF NAILING INTO THE DIAPHRAGMS CAN BE INSTALLED FLUSH WITH FACE OF SHEATHING. NAIL PENETRATIONS GREATER THAN 1/16" ARE NOT ACCEPTABLE. l.�e\��i�tit/e\ l���r�1�7e1►1�1»e���»►1��:7e��[�7►(.y CUTTING AND/OR NOTCHING OF WOOD STUDS OR PLATES SHALL NOT EXCEED 25% OF THE STUD/PLATE WIDTH IN EXTERIOR AND BEARING WALLS AND SHALL NOT EXCEED 40% OF THE STUD/PLATE WIDTH IN ANY NON -BEARING PARTITIONS. BORED HOLE DIAMETER IS LIMITED TO 40% OF STUD/PLATE WIDTH IN ANY STUD AND MAY BE 60% IN NONBEARING PARTITIONS OR IF STUD IS DOUBLED. MAINTAIN 5/8" MINIMUM EDGE DISTANCE FROM HOLE EDGE. 6. GYPSUM WALLBOARD NAILING ALL GYPSUM WALLBOARD SHALL BE NAILED TO ALL STUDS AND TOP AND BOTTOM PLATES WITH 6d COOLER NAILS OR NO. 13 GAUGE x 1 5/8" @ 7" OC (5d COOLER NAILS FOR 1/2 INCH GYPSUM SHEATHING). TYPICAL UNLESS NOTED OTHERWISE. INSTALLATION OF GWB SHALL BE SUCH THAT JOINTS ARE STAGGERED ON EACH SIDE OF A SINGLE WALL. EXISTING BUILDING CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. GENERAL STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. LEGEND DEFINITION SYMBOL DEFINITION SYMBOL DIRECTION OF FRAMING NATIVE SOIL PPIP,— — — — — EXTENT OF FRAMING GRANULAR FILL STRUCTURAL STEEL COLUMNS P COLUMN BEARING RATED SHEATHING ON BEAM BEAM CONTINUOUS SHEAR WALL OVER SUPPORT (SEE SCHEDULE) SWX COLUMN MARK Cl CONCRETE WALL (SEE SCHEDULE) BEARING STUD FOOTING MARK O WALL (SEE SCHEDULE) NON -BEARING HOLDOWN MARK STUD WALL (SEE SCHEDULE) BEARING STUD HANGER MARK O SHEAR WALL (SEE SCHEDULE) NON -BEARING FLAG NOTE STUD SHEAR WALL (SEE PLAN NOTES) CMU WALL STEEL MOMENT XXXXX A- �V FRAME CONN. ABBREVIATIONS (A) ABOVE ANCHOR BOLT ALTERNATE ARCHITECT BELOW BLOCKING HORIZ HORIZONTAL KING POST KIPS PER SQUARE INCH AB ALT KIP KSI ARCH (B) BLKG MECH MECHANICAL MOMENT FRAME NEAR SIDE MF NS BM BOT BEAM BOTTOM OC ON CENTER OPPOSITE PLATE PLACES POUNDS PER SQUARE INCH POUNDS PER SQUARE FOOT OPP BTWN BETWEEN COMPLETE JOINT PENETRATION PL CJP PLCS CLR CLEAR CONCRETE MASONRY UNIT PSI CMU PSF COL COLUMN P/T POSTTENSIONED CONC CONCRETE PT PRESSURE TREATED CONN CONNECTION REINF REINFORCING CONT CONTINUOUS REQ'D REQUIRED DBL DET DOUBLE DETAIL SCHED SIM SCHEDULE SIMILAR SLAB ON GRADE STANDARD SHEAR WALL TOP OF CONCRETE TOP OF STEEL TOP OF WALL TYPICAL UNLESS NOTED OTHERWISE DIM DIMENSION SOG EA EACH STD ELEV ELEVATION SW EXIST EXISTING TOC EXP FLR EXPANSION TOS FLOOR TOW FDN FTG FOUNDATION FOOTING FAR SIDE FULL HEIGHT GLUE -LAMINATED BEAM TYP LINO FS VFY VERIFY VERIFY IN FIELD VERTICAL FH VIF GLB VERT ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 �AwT8y wOF WAS$ iJ 465 t � �IONAL i J H ~ H � Z � m O m w Of � H H U � � of of Li 1 w w 0 a a N M W Q N Ln r-1 O oll W16/23 DESIGN: AL DRAWN: JEG CHECK: MTM JOB NO: 22294.10 DATE: 1 2/ 1 4/22 RESUB May 18 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ( w F_ 0 N w O Z U 00 z O� J W O Q Q V Of w = ZD vi F_ =moo U z D w M N O :2 0 000 Lli z SHEET: S102 An DRILL & EPDXY N WALL & FTG HOI INTO EXIST STEP FTG W/ SIMPS( EPDXY W/ FOUNDATION PLAN AND MAIN FLOOR FRAMING PLAN SCALE: 1/4" = V-0" - & EPDXY NEW STEM L & FTG HORIZ REBAR EXIST STEM WALL & N/ SIMPSON SET XP ;Y W/ 4" EMBED 4x6 POST ON EXIST 16" x 6" DEEP FTG, TYP - & EPDXY NEW STEM L & FTG HORIZ REBAR EXIST STEM WALL & N/ SIMPSON SET XP ;Y W/ 4" EMBED iF#2 POST ON V-6" i" x 10" THICK FTG 2'-0" 0 2'-0" 4'-0" T FOUNDATION PLAN NOTES: 1. REFERENCE TO SLAB ELEVATION SHOWN ON PLAN AND VERIFY W/ ARCH DRAWINGS. EXTERIOR FOOTINGS SHALL BEAR A MIN OF V-6" BELOW ADJACENT GRADE. 2. FOOTINGS AND SLAB ON GRADE SHALL BEAR ON FIRM NATIVE SOIL OR COMPACTED STRUCTURAL FILL AS SPECIFIED IN THE SOILS REPORT. 3. WHERE SLAB ON GRADE IS INDICATED, SLAB SHALL BE 4" THICK W/ 6x6-W1.4 x W1.4 WELDED WIRE FABRIC REINF. SLAB SHALL BE POURED OVER A 10 MIL VAPOR BARRIER OVER 6" OF 5/8" CRUSHED ROCK. 4. REFER TO PLAN AND "CONCRETE GENERAL NOTES" ON SHEET S1.1 FOR CONTROL JOINT PLACEMENT AND DETAIL 2/S3.1 FOR CONTROL JOINT CONSTRUCTION. 5. REFER TO SHEET S3.1 FOR FOUNDATION DETAILS. 6. PLACE ALL REINFORCEMENT PER THE STRUCTURAL NOTES AND FOUNDATION DETAILS. REFER TO SHEET S1.1 FOR ADDITIONAL CONCRETE DETAILING REQUIREMENTS. 7. FOUNDATION LEVEL HOLDOWNS ARE SHOWN ON ROOF FRAMING PLAN. REFER THE ROOF FRAMING PLAN NOTES ON SHEET S2.2 FOR HOLDOWN TYPES AND ROOF FRAMING PLAN FOR HOLDOWN ANCHOR BOLT LOCATIONS. 8. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, WALL LOCATIONS, AND CONCRETE ROUGH OPENINGS WITH ARCHITECTURAL DRAWINGS AND NOTIFY ALL PARTIES OF ANY DISCREPANCIES. 9. REFER TO DETAIL 3/S3.1 FOR PIPE PENETRATIONS THROUGH CONCRETE WALL OR FOOTINGS. 4 ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 ►' AwTxt; OF WAs 415 t S , �IONAL I J F-- H ~ H � Z � m 0 m w � F- F- U LLI w w 0 a a N M rlj LLI Q N Ln r-1 O oll W16/23 DESIGN: AL DRAWN: JEG CHECK: MTM JOB NO: 22294.10 DATE: 1 2/ 1 4/22 Z Q n V RESUB Z May 18 2023 CITY E DEVELOPMENT SERVICES DEPARTMENT Z � 0 J0 W 0 0-0 C) 00 J LZ Z L.L. J a 0 V) Z Q Q c � 0 0 _ z Z wro (n ono N :2 OZz -� L.L. Q � SHEET: S2ml ROOF FRAMING PLAN SCALE: 1/4" = V-0" 5 54.1 2'-0" 0 2'4" 7116 4'-0" ES TYPICAL ROOF FRAMING PLAN NOTES: 1. WALLS SHOWN ON ROOF FRAMING PLAN ARE WALLS BELOW ROOF FRAMING. 2. BEAMS SHOWN ON ROOF FRAMING PLAN SHALL BE ABOVE DOUBLE TOP PLATE UNLESS USED AS A DOOR OR WINDOW HEADER. TRUSS MFR SHALL DESIGN TRUSSES TO ACCOMMODATE BEAMS ABOVE DOUBLE TOP PLATE. 3. ROOF SHEATHING SHALL BE 7/16" PI 40/20 WITH 8d COMMON NAILS SPACED AT 6" OC AT ALL DIAPHRAGM BOUNDARIES, PANEL EDGES, SHEAR WALLS, COLLECTOR TRUSSES, AND BLOCKING OR TRUSS BLOCKING PANELS INDICATED ON PLANS. NAILING AT INTERMEDIATE FRAMING SHALL BE 8d COMMON NAILS @ 12" OC. REFER TO DETAIL 2/S5.1 FOR SHEATHING LAYOUT AND NAILING. 4. UNLESS NOTED OTHERWISE, HEADERS AT ALL EXTERIOR WALLS SHALL BE 48 HF#2 WHERE MAXIMUM SPAN = 5-5". 5. UNLESS NOTED OTHERWISE, DOOR HEADERS AT INTERIOR BEARING WALLS SHALL BE 4x8 HF#2 WHERE MAXIMUM SPAN = 4'-6", AND 6x8 HF#2 WHERE MAXIMUM SPAN = 5'-0". 6. STUD WALL FRAMING SHALL BE 2x HF STUDS @ 16" OC FOR ALL STUD WALLS SHOWN ON THE PLAN. 7. REFER TO SHEET S5.3 FOR TYPICAL ROOF FRAMING DETAILS. 8. REFER TO DETAIL 3/S5.1 FOR CONSTRUCTION OF MULTIPLE STUD COLUMNS. 9. <�> INDICATES SIMPSON HDU2 HOLDOWN PLACED AT BASE OF SHEAR WALL. REFER TO DETAILS 6 & 7/S3.1. 10. REFER TO THE STRUCTURAL NOTES SHEET FOR COLUMNS SUPPORTING TYPICAL BEARING WALL HEADER BEAMS. 11. ALL DIAPHRAGMS UNBLOCKED UNO. 12. + + HATCHED AREAS INDICATE VALLEY TRUSSES @ 24" OC APPLIED ABOVE PLYWOOD SHEATHING. REFER + + TO TYPICAL OVERFRAMING DETAIL ON S4.1. 13. COLUMNS AND BEARING WALLS SHOWN ON PLAN SHALL BE CONTINUED DOWN TO THE FOUNDATION UNLESS CARRIED BY A BEAM BELOW. 14. HOLDOWNS SHOWN ON ROOF FRAMING PLAN SHALL BE PLACED ON FOUNDATION LEVEL. 15. ROOF TRUSSES SHALL BE PRE-ENGINEERED BY OTHERS AND SPACED AT 24" OC, TYP. 16. ATTACH ALL ROOF TRUSSES TO WALLS BELOW WITH SIMPSON H2.5A HURRICANE TIES. 17. ALIGN (2) STUDS MIN BELOW ENDS OF GIRDER TRUSSES UNO ON PLANS. 18. TRUSSES MARKED "DRAG TRUSS" SHALL BE DESIGNED FOR 242 PLF SERVICE LEVEL AXIAL LOAD. Ai SHEAR WALL SCHEDULE APA-RATED MIN FRAMING AT SHEAR WALL RIM JOIST OR SILL PLATE NAILING TO SILL PLATE ANCHOR FOUNDATION SHEAR TYPE SHEATHING ADJOINING PANEL NAILING BLOCK CONN TO RIM/BLKG BOLT TO SLAB OR SILL PLATE SIZE CAPACITY EDGES (SEE NOTE 5) AT PANEL EDGES TOP PLATE FOUNDATION (PLF) BELOW 15/32" 2x STUD 0.131"0 x 2 1/2" LTP4 OR A35 0.131"0 x 3" @ 5/8"0 AB SW6 ONE SIDE AND BLKG @ 6" OC @ 24" OC 6" OC @ 5'-0" OC 2x 242 15/32" 2x STUD 0.131"0 x 2 1/2" LTP4 OR A35 0.131"0 x 3" @ 5/8"0 AB SW4 ONE SIDE AND BLKG @ 4" OC @ 20" OC 4" OC @ 4'-0" OC 2x 350 15/32" (2) 2x STUD AND 0.131"0 x 2 1/2" LTP4 OR A35 0.131"0 x 3" @ 5/8"0 AB SW3 ONE SIDE 2x FLAT BLKG @ 3" OC @ 15" OC 3" OC @ 3'-0" OC 2x 455 15/32" 3x STUD AND 0.131"0 x 2 1/2" LTP4 OR A35 0.131"o x 3" @ 5/8"0 AB SW2 ONE SIDE 2x FLAT BLKG @ 2" OC @ 12" OC 2.5" OC @ 2'-6" OC 2x 595 15/32" (2) 2x STUD 0.131"0 x 2 1/2" LTP4 OR A35 0.131"0 x 3" @ 5/8"0 AB 2SW4 BOTH SIDES AND BLKG @ 4" OC @ 10" OC 2" OC @ 2'-0" OC 2x 706 15/32" (2) 2x STUD 0.131"0 x 2 1/2" LTP4 OR A35 0.131 x 3" 5/8"0 AB 2SW3 BOTH SIDES AND BLKG @ 3" OC @ 7.5" OC @ 1.5" OC @ V-6" OC 2x 910 15/32" 3x STUD 0.131"0 x 2 1/2" LTP4 OR A35 0.131 x 3" 5/8"0 AB 2SW2 BOTH SIDES AND BLKG @ 2" OC @ 6" OC @ 1.5" OC @ 1'-0" OC 2x 1190 NOTES: 1. REFER TO THE TYPICAL SHEAR WALL DETAIL. 2. THE VALUES IN THIS TABLE ARE APPROPRIATE FOR HF GRADE STUDS AND HF GRADE PLATES & RIM/BLOCKING. 3. NAILS AT ADJOINING PANEL EDGES SHALL BE STAGGERED EACH SIDE OF THE COMMON JOINT. 4. WHERE PANELS ARE APPLIED ON BOTH FACES OF A WALL, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS, OR FRAMING SHALL BE 3x AT ADJOINING PANEL EDGES AND NAILS SHALL BE STAGGERED. 5. WHERE TABLE SPECIFIES (2) 2x FRAMING, CONNECT (2) 2x STUDS AND BLOCKING AS FOLLOWS: SW3 = (2) 0.131" 0 @ 3.5" OC, 2SW4 = 0.131"0 @ 2.5" OC, 2SW3 = (2) 0.131" 0 @ 1.5" OC. 6. NOTE THAT 3x FRAMING MAY BE USED IN LIEU OF (2) 2x FRAMING SPECIFIED IN TABLE. 7. INTERMEDIATE FRAMING TO BE WITH 2x MINIMUM MEMBERS. FIELD NAILING 12" OC MAXIMUM. 8. AT ALL 5/8"0 SILL PLATE ANCHOR BOLTS, INSTALL 1/4" x 3" x 3" PLATE WASHERS. EDGE OF PLATE WASHER SHALL BE WITHIN 1/2" OF SHEATHED EDGE. FOR DOUBLE SIDED SHEAR WALLS, USE WIDER PLATE WASHERS AS REQUIRED TO MEET THIS REQUIREMENT. 9. PROVIDE A MINIMUM OF 7" EMBEDMENT FOR AB INTO FOUNDATION OR STEM WALL. 10. 7/16" SHEATHING MAY BE USED IN PLACE OF 15/32" SHEATHING PROVIDED ALL STUDS ARE SPACED 16" OC OR PANELS ARE APPLIED WITH LONG DIMENSION ACROSS STUDS. 4 ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 �AwT8y wOF 1PAs$ ` �ASL t S �IONAL i J F-- Q H H Z � m O m w � H H U � � LLI w w 0 a a N M LLI Q l0 N Ln rl O oll W16/23 DESIGN: AL DRAWN: JEG CHECK: MTM JOB NO: 22294.10 DATE: 1 2/ 1 4/22 RESUB May 18 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z Q Ld Q 0 Z Z ova LLI = LL V) Lf) 0 CL N Z L.L. Lu M 0 0 0 N :2 Q O 00 � P►� � SHEET: S2m2 CORNER BARS x I Q "A" 1, MAY BE SUBSTITUTED FOR ALL 90° HOOKED BARS — STD 90° HOOK TYP UNO UNO, VERT CORNER BARS SHALL BE SAME SIZE TABULATED FOR MIN WALL REINF FOR THICKER WALL "A" = SPLICE LENGTH SEE NOTES, DETAILS, OR PLANS FOR Q (1) #4 VERT REQ'D REINF. ALL BARS TO BE CONT OR SPLICED PER STRUCTURAL NOTES STD 180° HOOK HORIZ CORNER BARS OF SIZE AND SPACING TO MATCH (2) #4 VERT REINF OF THINNER WALL n ® Q PLACE VERT REINF OUTSIDE EXCEPT AS OTHERWISE NOTED OR SHOWN TYPICAL CONCRETE WALL REINFORCING DETAIL SCALE: NTS 4"0 PERFORATED PVC PIPE PER LOCAL CODES WITH 6" OF 1" MINUS GRAVEL ALL AROUND, WRAPPED IN NON -WOVEN GEOTEXTILE FABRIC. SLOPE TO DRAIN 1/8" PER V-0" MIN. TURN DOWN PERFORATIONS AS SHOWN 0 0°0 o° O °O 00D on O °0 00 0 Coo 0 00 0 00 °00 O O000 0 0 1 LINE OF MAX EXCAVATION. 1 IF SOIL IS OVER EXCAVATED, REPLACE WITH LEAN MIX CONCRETE. FIRM BEARING SOIL OR COMPACTED STRUCTURAL FILL TYPICAL FOOTING DRAIN SCALE: 1" = V-0" NOTE: WHERE CONCRETE WALL WITH HT > 3'4" EXISTS, ROD MAY EXTEND 24" MIN INTO WALL W/ NUT & WASHER AS SHOWN COUNTERSINK ADDITIONAL END STUD AS REQ'D - THREADED ROD AS REQ'D FOR HOLDOWN W/ NUT AND WASHER AT BASE. EXTEND ROD INTO FTG, TYP UNO - TOP OF FTG HOLDOWN DETAIL SCALE: 1" = V-0" e® IN ALL AREAS WITH EXPOSED CONC FLOORS, EDGE SLAB WITH 1/8" MAX RADIUS AND FILL JOINT WITH SEALANT CONC SLAB ON GRADE PROVIDE 5/8" 0 x T-0" SLAB REINF AT CENTER OF SLAB SMOOTH SLIP DOWEL BARS OR AT TOP AND BOT. REINF AT 12" OC, TYP UNO SHALL NOT PASS THRU JOINT X X X X Ns X— I GREASE THIS HALF OF BAR TYPICAL CONSTRUCTION JOINT SAWCUT JOINT - IN ALL AREAS WITH EXPOSED CONC. FLOORS, FILL JOINT WITH SEALANT. IN LIEU OF SAWCUT JOINTS CONTRACTOR MAY USE ZIP CONC SLAB ON GRADE STRIP PLACED WITH SLAB SLAB REINF AT CENTER OF SLAB OR AT TOP AND BOT X X X X X X 7 TYPICAL CONTRACTION JOINT TYPICAL SLAB ON GRADE DETAILS SCALE: 1" = V-0" SHEAR WALL PER PLAN AND SCHED HOLDOWN PER PLAN AND SCHED II II II II IL II II II II II (4) 8d NAILS JOIST PER PLAN 2x BLKG @ 4'-0" MAX NOTE: FOR NOTES AND DETAILS NOT SPECIFICALLY CALLED z ® OUT REFER TO DETAIL 9 �o iD o O°O OOOo 0 00 °o°° 01 00 OO oO 0 --- 0 / / / i CRAWLSPACE SECTION (NON -BEARING' L101 SCALE: 1" = V-0" NOTE: EXTEND THREADED ROD BETWEEN JOISTS INTO STEM WALL BELOW. PROVIDE ROD COUPLER IF REQ'D. THREADED ROD AS REQ'D PER PLAN AND HOLDOWN SCHEDULE. INSTALL W/ HILTI HIT-HY 200 EPDXY EXISTING CONCRETE STEM WALL TOP OF EXISTING FOOTING 2x4 HF BLOCKING W/ 16d NAILS @ 6" OC BEAM PER PLAN AND SCHED COL PER PLAN AND SCHED SLEEVES TO CLEAR PIPE 1" ALL SIDES TOF BOF o x 2 Q 1F� LOWER BOF AS REQ'D PIPE TRENCH EXCAVATION PARALLEL 9 MIN TO FOOTING IS NOT ALLOWED TYP BELOW THIS LINE. STEP FTG AS REQUIRED FOR THIS CONDITION TYPICAL PIPE PENETRATION AT WALLS AND FOOTINGS VO PIPES ALLOWED IN PHIS REGION. LOWER =TGS AS REQ'D SCALE: 1/2" = V-0" SHEAR WALL PER PLAN AND SCHED HOLDOWN PER PLAN AND SCHED II II I I SQUASH BLKG TO IMATCH I HOEDOWN I I CHORD ABOVE II II II - II o II � II u HOLDOWN DETAIL (EXIST FOOTING SCALE: 1" = V-0" 0 8d NAILS @ 6" OC JOIST PER PLAN LAPPED AT BEAM 2x HF BLOCKING W/ 16d NAILS @ 6" OC SIMPSON PC MAX POST CAP PBS STANDOFF POST BASE in • 0 • "i m_j SIZE AND REINF PER PLAN CRAWLSPACE DETAIL SCALE: 1" = V-0" =a w 0 w 0_ NOTE: SILL PLAN D AB DIA RAISE STEM WALL AS REQ'D AT PERIMETER AND SPACING PER AREAS WHERE NEEDED DUE TO SITE GRADES. SHEAR WALL SCHED (2) #5 CONT TOP STUD WALL PER FRAMING PLAN NOTES PROVIDE BLOCK OUT AT DOOR OPENINGS SHEATHING AND NAILING SLAB ON GRADE AND PER PLAN AND SHEAR SUBGRADE PER WALL SCHEDULE z_Q x FOUNDATION PLAN - = #5 @ 15" OC EA WAY PAVING OR FINISHED "' CENTERED IN WALL GRADE PER ARCH DRAWINGS 0 0 ( X X 0 po o°o 00 cf 0 0 ° O oO °° ° °° ° °°°� °o 0 °o 0 0 D 0 0° O oo 00 0 0° D o 00 z 000O O .0 °0 Oo O o 1-1 00 o O° ° O = �� Q o O ° ° 0 w o- 0 0 OO 0 O ® ® — —® w 0 FOOTING DRAIN / PER DETAIL 5 / 6" m u / ALT HOOK SIZE & REINF AS SHOWN PER PLAN TYPICAL STEM WALL DETAIL SCALE: 1" = V-0" EXISTT&G DECKING. CONTRACTOR TO FIELD VERIFY THICKNESS CRAWLSPACE SECTION AT NEW/EXIST SCALE: 1" = V-0" EXIST STUD WALL WHERE OCCURS SHEATHING & NAILING PER PLAN NOTES PT 2x FULL DEPTH LEDGER 5/8"0 x 5" SIMPSON TITEN HD @ 16" OC JOIST PER PLAN EXIST FINISHED GRADE z PROPOSED GRADE IN CRAWLSPACE 9 cz w I AD CDI IrF ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 J U � m kRS TO MATCH pF WAS$l� �0 DOTING /I REINF ti JRBED EARTH OR 46141Z -TED FILL PER SS, I�NAL JRAL NOTES W16/23 T = FTG THICKNESS PER PLAN, SCHED, AND DETAILS TYPICAL STEPPED WALL FOOTING 7 / SCALE: 1/2" = V-0" SHEATHING AND NAILING PER PLAN AND SHEAR WALL SCHED SILL PLATE NAILING PER SHEAR WALL SCHED CONT 2x RIM BOARD LTP4 FRAMING ANCHOR W/ SPACING PER SHEAR WALL SCHED MIA SHEATHING AND NAILING PER FOUNDATION PLAN NOTES JOIST PER PLAN SIMPSON A35 EVERY OTHER JOIST l� IPT SILL PIL W/ ANCHOR x BOLT SIZE ANDS ACTING PER SHEAR WALL - SCHEID FOOTING DRAIN 1O PER TYP DETAIL #5 @ 15" OC z EA WAY 0 0 ° 0°0 00 °0 DOOOn _ o 00 0 0 O ° 0o 0 Imo. O 0 ° ° 00 O00 0 000 _® ' / m U / SIZE AND REINF ALT HOOK PER PLAN AS SHOWN 1 CRAWLSPACE SECTION (BEARING) SCALE: 1" = V-0" PAVING OR GRADE PER ARCH DWGS -� I I- =Q w ow o_ #5 CONT NOSING BAR SLAB ON GRADE AND SUBGRADE PER FOUNDATION PLAN. SLOPE SLAB PER ARCH PLAN x x x x x x— 0 0 0 O 000 °o o 000 °o o O°o X _ oz (1) #5 CONT 10" THICKENED EDGE SLAB V % SCALE: 1" = V-0" J ~ H I_ Z :�i m 0 m I__ w � H H U � � W w w 0 a a N M LLJ N N N Ln .H O Y Q DESIGN: AL DRAWN: JEG CHECK: MTM JOB NO: 22294.10 DATE: 1 2/ 1 4/22 RESUB May 18 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT r n V I J Q 0 ~ N W W O 0 U o0 Cy) w J Z a 0 W cy � 0 _ Z Z wrV)0 D O Lii 00000 SHEET: S3.1 SHEATHING AND NAILING PER ROOF FRAMING PLAN NOTES 2x OUTLOOKER (24" MAX OVERHANG) GABLE END TRUSS SHEATHING AND NAILING TO MATCH SHEAR WALL BELOW SHEATHING AND NAILING PER PLAN AND SHEAR WALL SCHEDULE DIAPHRAGM SHEATHING PER ROOF BOUNDARY NAILING FRAMING PLAN NOTES PER ROOF FRAMING PLAN NOTES TRUSS BLOCKING DESIGNED AND � �( ROOF SHEATHING AND PROVIDED BY TRUSS MFR. DESIGN NAILING PER ROOF BLOCKING FOR 242 PLF IN -PLANE FRAMING PLAN NOTES ROOF SHEATHING AND SHEAR AT SHEAR WALLS ONLY NAILING PER ROOF DIAPHRAGM BOUNDARY 2x4 BLOCKING W/ SILL DIAPHRAGM BOUNDARY FRAMING PLAN NOTES NAILING PER ROOF PLATE NAILING PER NAILING PER ROOF FRAMING PLAN NOTES SHEAR WALL SCHEDULE FRAMING PLAN NOTES 2x4 BLKG W/ SILL PL NAILING PER SHEAR WALL SCHED FULL DEPTH BLOCKING RIPPED TO MATCH SLOPE FULL DEPTH BLKG OF ROOF RIPPED TO MATCH SLOPE OF ROOF SIMPSON A35 FRAMING SILL PLATE NAILING ANCHOR PER SHEAR PER SHEAR WALL WALL SCHEDULE SCHEDULE PRE-ENGINEERED ROOF PRE-ENGINEERED TRUSS PER PLAN SILL PL NAILING PER SCISSOR TRUSS PER PLAN SHEAR WALL SCHED PROVIDE BOUNDARY SIMPSON H2.5A PRE-ENGINEERED SIMPSON H2.5A PROVIDE BOUNDARY BOUNDARY NAILING PER SHEAR WALL SCHEDULE TIE AT EACH TRUSS ROOF TRUSS PER PLAN NAILING AT TOP PLATE PER TIE AT EACH TRUSS NAILING AT TOP PLATE SHEAR WALL SCHEDULE PER SHEAR WALL SIMPSON H2.5A SHEATHING AND SCHEDULE EACH TRUSS NAILING PER PLAN STUD WALL FRAMING STUD WALL FRAMING AND SHEAR WALL PER PLAN NOTES SHEATHING AND NAILING PER PLAN NOTES SHEATHING AND SCHEDULE PER PLAN AND SHEAR NAILING PER PLAN AND WALL SCHEDULE SHEAR WALL SCHEDULE TYPICAL TRUSS SUPPORT DETAIL SCALE: 1" = V-0" DIAPHRAGM BOUNDARY NAILING PER ROOF FRAMING PLAN NOTES A35 CLIP PER SW SCHED (24" OC MAX) A35 EACH LINE OF BLOCKING SIMPSON LSTA15 STRAP EACH SPLICE OPTION A. BLOCKING AND STRAPS TYPICAL GABLE END SECTION SCALE: 1" = V-0" 2x4 BLOCKING FOR (3) TRUSS SPACES @ 4'-0" OC MAX 6d COOLER NAILS @ 6" OC OVER EXTENTS OF BLOCKING (4) 8d NAILS INTO EA BLOCK TYPICAL SCISSOR TRUSS SUPPORT DETAIL SCALE: 1" = V-0" 2x4 BLOCKING EACH BRACE r/ II I (6) 10d 2x4 BLOCKING EACH BRACE PROVIDE (2) 2x4 OR (1) 2x6 DIAGONAL BRACE AT 4'-0" OC NOTE: REFER TO CASE A FOR INFORMATION NOT SPECIFICALLY CALLED OUT OPTION B. BRACING DIAPHRAGM BOUNDARY NAILING PER ROOF FRAMING PLAN NOTES FULL DEPTH BLOCKING RIPPED TO MATCH SLOPE OF ROOF 16d NAILS @ 6" OC TYPICAL TRUSS BLOCKING DETAIL SCALE: 1" = V-0" ROOF SHEATHING AND NAILING PER ROOF FRAMING PLAN NOTES 2x4 BLOCKING W/ SILL PLATE NAILING PER SHEAR WALL SCHEDULE PRE-ENGINEERED ROOF TRUSS PER PLAN SIMPSON H2.5 TIE AT EACH TRUSS DROP BEAM PER PLAN ROOF TRUSS SUPPORTED BY BEAM SCALE: 1" = V-0" CONT 2x4 FLAT BLKG PER DETAIL 1 DIAPHRAGM BOUNDARY NAILING PER ROOF PLAN NOTES 2x FULL DEPTH BLOCKING RIPPED TO MATCH ROOF SLOPE PANEL EDGE NAILING PER SHEAR WALL SCHEDULE SHEATHING AND NAILING PER PLAN AND SHEAR WALL SCHEDULE LOWER ROOF SECTION SCALE: 1" = V-0" 2x HF BLKG AT RIDGE, TYP VALLEY TRUSSES PER ROOF PLAN, TYP 2x4 SLEEPER TYP W/ (2) 0.131"0 x 3 1/2" NAILS EACH TRUSS PRE-ENGINEERED ROOF TRUSSES PER ROOF PLAN TYPICAL OVERFRAMING DETAIL SCALE: 1" = V-0" ROOF SHEATHING AND NAILING PER ROOF PLAN NOTES TRUSSES PER PLAN [.7111II%Y�71�:V#.7:Iq STUD WALL FRAMING PER PLAN DIAPHRAGM BOUNDARY NAILING PER PLAN NOTES 2x4 CONT BLKG HANGER PER TRUSS MFR C G ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 �1MOTHI' � OF 1PAs$ ` SAL _ZONAL H � Z � m O m GIRDER TRUSS F D w PER PLAN 0_ N — H H U � � W w w CONT 2x4 BLKG 0 a a N M rlj Q 1:* QD C) N Ln .� O W16/23 DESIGN: AL DRAWN: JEG CHECK: MTM JOB NO: 22294.10 DATE: 1 2/ 1 4/22 RESUB May 18 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O W p Z O J W Q ova LLI = Lw V) Q 0 N Z L.L. CL w r) O p 0 N :2 p � u, SHEET: s mi C GI HEADER PER PLAN CRIPPLE STUDS PER PLAN; DO NOT CUT AWAY MATERIAL FROM CRIPPLE STUDS FULL -HEIGHT HOLDOWN CHORD AB W/ SIMPSON BP PL WASHER, TYP PT SILL PL PER SHEAR WALL SCHED CONCRETE FOOTING OR P/T SLAB STAGGER NAILS ON EA SIDE OF PANEL JOINT AS REQUIRED PER SHEAR WALL SCHED -r-I------ - - - - - - - - - - - - - - - - - - - - - -------F------rl-1 I.1 I•I I'I I'I I'I I.I 11•I II II II II II II III II II II II II II 11w I II II II II II II III •II II II I II II II II III l i I I I I I •I � I I I I I I I I I '� I•I I I j I I I I I FRAMING AT ADJOINING I I �•I I I I I I I I I I I I I PANEL EDGES PER SHEAR I I I IIII 1.1 I•I I• 1• I'I WALL SCHEID I I I I• I I I I I I I I I I I I I I I II II I.I I II ii ii II III I II II I I II II II II 11•I I•II I 11 I• I I II II II II III �I I�j 1�1 ICI ICI 1�1 I IIII 11 II I' I 11 II II II II IIII I j I I j •I I j ,J L;--— I.I I 1 1 I I I I 1 1 ---- I IIII 11 II I' I 11 II II II II IIII 11 II j •I Ij II II II IIII 11 II I• I 11 II II II IIII 11 II I.I 11 II II II IIII I.1 I•I I I 1.1 ICI ICI ICI IIII 11 II I' I 11 II II II 11 II I •I 11 II II II 11 II I I 11 II II II 11 II I• I 11 II II II II I.I 11 II II II I•I I I 1.1 ICI ICI ICI II I' I 11 II II II II I •I 11 II II II II I I 11 II II II II I• I 11 II II II II I •I A 11 II II II I•I I I 1.1 ICI ICI ICI II I' I 11 II II II 1------L _1L-------LL_------_L II ^— II II I I I I I I I I I I I 11 II II 11 1L_A_1L______I NOTES: 1. REFER TO STRUCTURAL NOTES FOR ADDITIONAL INFORMATION. 2. FOR SHEAR WALLS WHERE NO HOLDOWNS ARE SPECIFIED THE FIRST AB SHALL BE LOCATED NOT MORE THAN 1'-0" AND NOT LESS THAN (7) BOLT DIAMETERS FROM END OF WALL. TYPICAL SHEAR WALL DETAIL SCALE: 3/4" = V-0" AB SIZE AND SPACING I I II PER PLAN AND SHEAR _; WALL SCHEDULE, TYP RIM BOARD OR BLOCKING (t PANEL EDGE NAILING PER SHEAR WALL SCHEDULE, TYP PANEL EDGE NAILING INTO HOLDOWN CHORDS, TYP INTERMEDIATE NAILING @ 12" OC SHEATHING PER PLAN AND SHEAR WALL SCHEDULE HOLDOWN CHORD PER SCHEDULE. REFER TO TYPICAL BUILT-UP COLUMN DETAIL ADDITIONAL END STUD IF REQUIRED TO PROVIDE COUNTERSINK FOR HOLDOWN BOLTS HOLDOWN ANCHORAGE PER PLAN AND SCHEDULE SIMPSON CNW COUPLER 1/2" TO NUT W/ SIZE TO MATCH SHEATHED EDGE HOLDOWN ANCHORAGE PANELEDGE NAILING PER SHEAR WALL SCHED CONTINUE HOLDOWN CHORD TO FOUNDATION CONCRETE STEM WALL CONCRETE FOOTING PLATE WASHER PER SHEAR WALL SCHED SECTION A -A SCALE: 1 1/2" = V-0" NOTE: STAGGER SHEATHING AS SHOWN. INTERMEDIATE FRAMING MEMBERS SHEATHING PANEL, TYP CONTINUOUS PANEL EDGES SUPPORTED PANEL EDGES 2x OR 3x BLOCKING ONLY IF BLOCKED DIAPHRAGM IS SPECIFIED FRAMING MEMBERS W/ SPACING PER PLAN `L DIAPHRAGM BOUNDARY (SHEAR WALL, BEAM, OR DRAG STRUT) TYPICAL FLOOR/ ROOF SHEATHING DETAIL SCALE: NTS 2 1/4" END DISTANCE, TYP (2) ROWS OF (8) 0.131" 0 x 3" NAILS @ 3" OC EA SIDE OF SPLICE AND (2) @ 9" OC ELSEWHERE W/ 1 1/2" EDGE DISTANCE 3" OC \ SPACING TOP CHORD SPLICE AT LOCATIONS WHERE IT IS NOT POSSIBLE BOTTOM TO INSTALL THE SPECIFIED 0.131" 0 CHORD SPLICE NAILS, THE CONTRACTOR SHALL SPLICE INSTALL SIMPSON CS20 STRAPS EA SIDE OF WALL AT SPLICE. INSTALL EA STRAP W/ (12) 10d AT EA END. WHERE BOTH PLATES ARE CUT, INSTALL CS20 STRAPS AT EA PLATE AND EA SIDE OF THE WALL. 6'-0" MIN BETWEEN SPLICES SPLICES TO OCCUR AT CENTER OF VERTICAL STUDS TOP CHORD SPLICE BOTTOM CHORD SPLICE TYPICAL TOP PLATE SPLICE DETAIL SCALE: 1" = V-0" ADJACENT NAILS IN A ROW ARE TO BE DRIVEN FROM OPPOSITE SIDES, TYP FOR 2x4 STUDS, PROVIDE SINGLE ROW OF NAILS STAGGERED EA SIDE WITH 1 1/2" EDGE DISTANCE. FOR 2x6 STUDS, PROVIDE (2) ROWS OF NAILS SPACED AT 2 1/2" W/ 1 1/2" EDGE DISTANCE 9" OC MAX SPACING BETWEEN ADJACENT NAILS IN A ROW 0.131" 0 x 3" NAILS, TYP (5) STUDS MAX TO BE USED FOR BUILT-UP COLUMNS TYPICAL BUILT-UP STUD COLUMN DETAIL SCALE: 1" = V-0" SIMPSON A35 (ONLY REQUIRED AT EXTERIOR HEADERS GREATER THAN 6' SPAN) (6) 0.131"0 x 3" NAILS lWall1e1lt01011L1 NAILING PER TYP BUILT-UP STUD COLUMN DETAIL AT HOLDOWNS: PROVIDE FULL HT HOLDOWN CHORDS PER HD SCHED OTHERWISE: (1) 2x FULL HT TYPICAL HEADER DETAIL SCALE: 1" = V-0" EDGE NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP 0.131"0 x 3" NAILS @ 9" OC (2) ROWS OF 0.131" 0 x 3" NAILS @ 9" OC STUD WALL PER FRAMING PLAN NOTES, TYP SHEATHING (OR GWB) AND NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP A. CORNER INTERSECTION EDGE NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP TYP DOUBLE TOP PLATE BEAM OR HEADER PER PLAN AND NOTES CRIPPLE STUDS PER PLAN AND COLUMN SCHEDULE OR STRUCTURAL NOTES B. 'T' INTERSECTION TYPICAL WALL INTERSECTION DETAIL SCALE: 1" = V-0" 2x6 STUD @ 2x4 CROSS WALL 2x8 STUD @ 2x6 CROSS WALL EDGE NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP 0.131"0 x 3" NAILS @ 9" OC STUD WALL PER FRAMING PLAN NOTES, TYP SHEATHING (OR GWB) AND NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 �Awwly 6v WAS$ iJsL��ti �IONAL i W16/23 N M LLI Q N Ln .H O Y Q DESIGN: AL DRAWN: JEG CHECK: MTM JOB NO: 22294.10 DATE: 1 2/ 1 4/22 RESUB May 18 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT / 1 W 0 0 N C� W U 000 Z Z O) W J o a Q V) Wfy = L0 0 = CL Ifl— N Z 0 w r) 0 O o N :2 0 0 0 z -7 00 W � SHEET: Al S5ml