REVIEWED BLD2023-0460+HEATING +4.12.2023_5.09.10_PM+3480124BLD2023-0460 Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. REVIEWED BY CITY OF EDMONDS Protect Information ilontact Information Erika and Trevor Hill IHeidiHelgeson/H2D Architecture+ Design 931 Carol Way 23020 Edmonds Way, #113 Edmonds, WA 98020 1 Edmonds, WA 98020 Heating System Type: O All Other Systems OO Heat Pump RECEIVED To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) Edmonds AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 3,213 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 7.9 25,379 Glazing and Doors U-Factor X Area = UA Instructions U-0.30 . 0.300 J 749 224.79 Skylights U-Factor X Area = UA Instructions 0.50 54 27.00 Insulation Attic U-Factor X Area = UA Instructions R-49 I 0.026 1 2,320 60.33 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions 6 R-38 vented I 0.027 739 19.95 Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions 0.056 2,063 115.51 L R-21 Intermediate Floors U-Factor X Area UA Instructions 0.029 519 15.04 R-30 � Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions Select R-value I No selection J 400 Slab Below Grade (see Figure 1) F-Factor X Length UA Instructions No Slab Below Grade in this project. � 0.000 --- Slab on Grade (see Figure n F-Factor X Length UA Instructions No Slab on Grad e in this project. � --- Location of Ducts Instructions Duct Leakage Coefficient Conditioned Space I 1.00 Sum of UA 462.62 Figure 1. Above Grade Apr 14 2023 46 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Envelope Heat Load 21,280 Btu / Hour Sum of UA x AT Air Leakage Heat Load 12,608 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 33,889 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 33,889 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 42,361 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump (07/01/13)