Loading...
REVIEWED-BLD2023-0474+WSEC+4.4.2023_8.11.41_PM+3463510BLD2023-0474 REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT? simpie mating system size: tnfasnington state ...................................... This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information ADDITION & REMODEL SANCHEZ & McPHILLIPS RESIDENCE O All h • Heat Pm Heating System Tm ype. a er Systes ° p RECEIVED To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Apr 18 2023 Instructions Design Temperature Difference (AT) 46 Edmonds NDS AT = Indoor (70 degrees) - Outdoor Design Temp CITY E DEVELOPMENT SERVICES DEPARTMENT A' -f Buildina Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) Average Ceiling Height Instructions Average Ceiling Height (ft) Glazing and Doors Instructions U-0.28 Skylights Instructions Insulation Attic Instructions R-49 Single Rafter or Joist Vaulted Ceilings Instructions R-38 Vented Above Grade Walls (see Figure 1) Instructions R-21 Intermediate 262 Conditioned Volume 8.5 2,227 U-Factor X Area = UA 0.280 65 18.20 U-Factor X Area = UA 0.50 10 5.00 U-Factor X Area = UA 0.026 0� Floors Instructions R-38 Below Grade Walls (See Figure 1) Instructions No Below Grade Walls in this project. Slab Below Grade (see Figure 1) Instructions No Slab Below Grade in this project. � molk— Slab on Grade (see Figure 1) Instructions No Slab on Grade in this project. Location of Ducts Instructions Conditioned Space Figure 1. Above Grade U-Factor X Area 0.027 262 U-Factor X Area 0.056 589 U-Factor X Area 0.025 262 U-Factor X Area 0.028 0� F-Factor X Length 0.303 0� F-Factor X Length Sum of UA UA 7.07 UA 32.98 UA 6.55 UA Duct Leakage Coefficient 1.00 UA UA 69.81 Envelope Heat Load 3,211 Btu/Hour Sum of UA x AT Air Leakage Heat Load 1,106 Btu/Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 4,318 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 4,318 Btu / Hour Ducts in unconditioned space: sum of buildinq heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 5,397 Btu / Hour Buildinq and duct heat loss x 1.40 for forced air furnace Buildinq and duct heat loss x 1.25 for heat pump (07101113)