REVIEWED RESUB2 BLD2023-0501+Structural_Calculations+12.3.2023_4.15.49_PM+3930528Structural Calculations Cover Sheet BLD2023-0501
Project Number: 2022.151 Date: November 17, 2023
Project Name: Lane Residence Architect: Michael Schoffner
Structural Design For: Structural design for a remodel of an existing residence.
Construction Type: Conventional wood framing with conventional concrete
foundation.
CODES �� A S. APO
2018 International Building Code (IBC)°F Wh�ti�
2018 NDS
ASCE 7-16
LOADS c<`S, c�/RAL ENS' U
S/ONA%_
Dead Loads As required
Roof snow Load 25 psf
Floor Load 40 psf
Wind 110 mph, Exposure B, Per ASCE 7-16 Section 28, Kzt = 1.53
Seismic Per ASCE 7-16 Section 12
Peak Ground Accelerations (PGA) based on USGS Hazards Program (by address).
PGA 1 sec = .453 PGA .2 sec = 1.306 %V = .134 * DL
Material Design Values
RESUB
IZMIL' W1910491
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
2-
..........
REVIEWED
BY
CITY OF EDMONDS
BUILDING DEPARTMENT?
Soils (assumed) Minimum 1,500 psf allowed bearing (subject to field verification)
Concrete fc=2,500 psi; 5-1/2 sack mix, or alternate mix pre -approved by bldg. dept.
Reinforcing Grade 60; Fy=60,000 psi minimum
Sawn Lumber Joists, Rafters: Hem -Fir #2 and better
Beams, Posts: DF-L #2
Studs & Plates: Hem -Fir Standard
Glu-Lam Beams 24F-V4 for simple span beams, 24F-V8 for cantilevered beams
Parallam Beams 2.2E PSL, Fb=2,900 psi, Fv=290 psi, E=2.2* 10^6 psi (minimum)
Microllam Beams 1.9E LVL, Fb=2,600 psi, Fv=285 psi, E=1.9* 10^6 psi (minimum)
Structural Steel ASTM A36, Fy=36 ksi Plates, ASTM A992, Fy=50ski Wide Flanges,
ASTMA500, Fy=46 ksi Tubes
Anchor Bolts ASTM A325 hold down bolts, F 1554 Anchor Bolts, A307 other bolts
CONSULTING STRUCTURAL ENGINEERING SERVICES, INC.
6311 - 17th Avenue NE, Seattle WA 98115 (206) 527-1288 email john@cses-engineering.com
Structural Engineering Consulting and Design
John S. Apolis, P.E. CSES, Inc. Job number: 2022.151
Project: Lane Residence Date: 8-Feb-23
Architect: Michael Schoffner Pate number: R2
BEAM DESIGN (Uniform Load+Concentrated Load)
2018 International Building Code (IBC) 2018 NDS
Beam Description: Roof Joist
Fully Supported: Snow Load: � Wind Load:
Repetitive Member: 1 P.T. Lumber: Wet Use:
Geometry and Loads:
Span: 6.5 ft ributary Width: 2 ft P Location: 3.833 ft
Add'l uniform DL: DL unit load: 15 psf Concentrated DL:
Add'l uniform LL: LL unit load: 40 psf Concentrated LL:
Add'l uniform SL: SL unit load: 25 psf Concentrated SL:
Add'l uniform WL: WL unit load: Concentrated WL:
DL Reaction 1:
98 lbs
DL Reaction 2:
98 lbs Note: Design automatically uses
LL Reaction 1:
260 lbs
LL Reaction 2:
260 lbs ASD load combinations
SL Reaction 1:
163 lbs
SL Reaction 2:
163 lbs
WL Reaction 1:
0 lbs
WL Reaction 2:
0 lbs
Total Reaction 1:
414 lbs
Total Reaction 2:
414 lbs
Material Properties:
E
1.3 msi
E'
1.3 msi
Fb
850 psi
Fb'
1461 psi
Fv
150 psi
Fv'
173 psi
Fc perp
405 psi
Fc perp'
405 psi
Emin
0.47 msi
Emin'
0.47 msi
Deflection analysis:
For total load:
Allowed deflection criteria,
span/ 240
For LL only:
Allowed deflection criteria,
span/ 360
Max. allowed total defl:
0.33 in
Max LL defl:
0.22 in
Total defl. * I:
4.94 inA4
Required 1:
15.21 in^4
LL defl. * I:
4.02 inA4
Required 1:
18.54 in^4
Actual deflections:
TOTAL:
0.24 in
0.19 in
Force analysis:
Max. moment: 673 ft-lb Max Shear: 414 lbs
Selected Member (1) H F #2 1.5 x 5.511
Member properties:
Provided:
Required:
Moment of inertia:
20.8 in^4
18.54 in^4
Section Modulus:
7.56 in^3
5.53 in^3
Section Area:
8.25 in^2
3.6 in 2
Bearing Area:
1.02 in^2
Minimum bearing dimensions:
1.5 in x
0.68 in
John S. Apolis, P.E. CSES, Inc. Job number: 2022.151
Project: Lane Residence Date: 8-Feb-23
Architect: Michael Schoffner Page number: R3
BEAM DESIGN (Uniform Load+Concentrated Load)
2018 International Building Code (IBC) 2018 NDS
Beam Description: Roof End Rafter / Skylight Rafter
Fully Supported: Snow Load: � Wind Load:
Repetitive Member: 1 P.T. Lumber: Wet Use:
Geometry and Loads:
Span: 6.5 ft ributary Width: 3.5 ft P Location: 3.833 ft
Add'l uniform DL: DL unit load: 15 psf Concentrated DL:
Add'l uniform LL: LL unit load: 40 psf Concentrated LL:
Add'l uniform SL: SL unit load: 25 psf Concentrated SL:
Add'l uniform WL: WL unit load: Concentrated WL:
DL Reaction 1:
171 lbs
DL Reaction 2:
171 lbs Note: Design automatically uses
LL Reaction 1:
455 lbs
LL Reaction 2:
455 lbs ASD load combinations
SL Reaction 1:
284 lbs
SL Reaction 2:
284 lbs
WL Reaction 1:
0 lbs
WL Reaction 2:
0 lbs
Total Reaction 1:
725 lbs
Total Reaction 2:
725 lbs
Material Properties:
E
1.3 msi
E'
1.3 msi
Fb
850 psi
Fb'
1461 psi
Fv
150 psi
Fv'
173 psi
Fc perp
405 psi
Fc perp'
405 psi
Emin
0.47 msi
Emin'
0.47 msi
Deflection analysis:
For total load:
Allowed deflection criteria,
span/ 240
For LL only:
Allowed deflection criteria,
span/ 360
Max. allowed total defl:
0.33 in
Max LL defl:
0.22 in
Total defl. * I:
8.65 inA4
Required 1:
26.62 in^4
LL defl. * I:
7.03 inA4
Required 1:
32.44 in^4
Actual deflections:
TOTAL:
0.21 in
0.17 in
Force analysis:
Max. moment: 1178 ft-lb Max Shear: 725 lbs
Selected Member (2) H F #2 1.5 x 5.5
Member properties:
Provided:
Required:
Moment of inertia:
41.59 in^4
32.44 in^4
Section Modulus:
15.13 in^3
9.68 in^3
Section Area:
16.5 in^2
6.31 in 2
Bearing Area:
1.79 in^2
Minimum bearing dimensions:
3. in x
0.6 in
John S. Apolis, P.E. CSES, Inc. Job number: 2022.151
Project: Lane Date: 17-Nov-23
Architect: Page number: R4
BEAM DESIGN (Uniform Load+Concentrated Load)
2018 International Building Code (IBC) 2018 NDS
Beam Description: West window headers
Fully Supported: Snow Load: 1 Wind Load:
Repetitive Member: P.T. Lumber: Wet Use:
Geometry and Loads:
Span: 12.5 ft Tributary Width: 2 ft P Location: 12.5 ft
Add'l uniform DL: DL unit load: 15 psf Concentrated DL:
Add'l uniform LL: LL unit load: Concentrated LL:
Add'l uniform SL: SL unit load: 25 psf Concentrated SL:
Add'l uniform WL: WL unit load: Concentrated WL:
DL Reaction 1:
188 lbs
DL Reaction 2:
188 lbs
Note: Design automatically uses
LL Reaction 1:
0 lbs
LL Reaction 2:
0 lbs
ASD load combinations
SL Reaction 1:
313 lbs
SL Reaction 2:
313 lbs
WL Reaction 1:
0 lbs
WL Reaction 2:
0 lbs
Total Reaction 1:
500 lbs
Total Reaction 2:
500 lbs
Material Properties:
E
1.6 msi
E'
1.6 msi
Fb
900 psi
Fb'
1346 psi
Fv
180 psi
Fv'
207 psi
Fc perp
625 psi
Fc perp'
625 psi
Emin
0.58 msi
Emin'
0.58 msi
Deflection analysis:
For total load: Allowed deflection criteria, span/
240
For LL only: Allowed deflection criteria, span/
360
Max. allowed total defl:
0.63 in
Max LL defl:
0.42 in
Total defl. * I:
27.47 in^4
Required I:
43.95 in^4
LL defl. * 1:
17.17 in^4
Required 1:
41.2 in^4
Actual deflections:
TOTAL:
0.25 in
0.15 in
Force analysis:
Max. moment: 1563 ft-lb
Max Shear: 500 lbs
Selected Member: (1) DF #2 3.5 x 7.25
Member properties:
Provided:
Required:
Moment of inertia:
111.15 in^4
43.95 in^4
Section Modulus:
30.66 in^3
13.94 in^3
Section Area:
25.38 in^2
3.62 in^2
Bearing Area:
0.8 in^2
Minimum bearing dimensions:
3.5 in x
0.23 in
.IFORTEWEB
Roof, R12: Existing North GLB
1 piece(s) 5 1/2" x 9" 24F-V4 DF Glulam
PASSED
I
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
7201 @ 3' 5"
12513 (3.50")
Passed (58%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
7189 @ 2' 6 1/2"
10057
Passed (71%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
6594 @ 2' 6"
17078
Passed (39%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.009 @ 1' 10 7/16"
0.108
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.016 @ 1' 10 7/16"
0.162
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 3' 3".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Column - DF
3.50"
3.50"
1.50"
1152
1690
2842
Blocking
2 - Column - DF
3.50"
3.50"
2.01"
2899
4302
7201
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
T 7" o/c
Bottom Edge (Lu)
3' 7" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 3' 7"
N/A
12.0
Linked from: R9:
1 - Point (lb)
2' 6" (Top)
N/A
2751
4161
North Purlin
Backspan Beam,
Support 1
Linked from: Rll:
2 - Point (lb)
2' 6" (Top)
N/A
1257
1831
Middle Purlin
Backspan Beam,
Support 2
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Weyerhaeuser
Job Notes
William Nocka
CSES
(978) 503-9935
llwnocka@gmail.com
R12
.I FO RT E W E B MEMBER REPORT
Roof, R13: Existing South GLB
1 piece(s) 5 1/2" x 9" 24F-V4 DF Glulam
PASSED
Overall Length: S' 7'
I
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1857 @ 2"
12513 (3.50")
Passed (15%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1845 @ 1' 1/2"
10057
Passed (18%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
4752 @ 2' 9"
17078
Passed (28%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.018 @ 2' 9 7/16"
0.175
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.031 @ 2' 9 7/16"
0.262
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 5' 3".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on Nos.
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Column - DF
3.50"
3.50"
1.50"
774
1083
1857
Blocking
2 - Column - DF
3.50"
3.50"
1.50"
751
1049
1800
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
5' 7" o/c
Bottom Edge (Lu)
5' 7" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 5' 7"
N/A
12.0
Linked from: Rll:
1 - Point (lb)
2' 9" (Top)
N/A
1458
2132
Middle Purlin
Backspan Beam,
Support 1
Notes
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Weyerhaeuser
Job Notes
William Nocka
CSES
(978) 503-9935
llwnocka@gmail.com
R13
John S. Apolis, P.E. CSES, Inc. Job number: 2022.151
Project: Lane Residence Date: 8-Feb-23
Architect: Michael Schoffner Page number: R14
Post Design (Combined Axial and Moment Loading)
2018 International Building Code (IBC) 2018 NDS
Post Description: Existing South GLB Support Posts
Snow Load: 1 Wind Load:
Repetitive Member: P.T. Lumber:
Geometry and loads:
Height
8 ft
w(d)
0 plf M(d)
Axial Load
5797 lbs
w(b)
0 plf M(b) 0 ft-lbs
Le(d)
8 ft
Le(b)
8 ft
Material Properties:
Fbl
850 psi
Fb(d)'
977.5 psi
Fb2
850 psi
Fb(b)'
977.5 psi
Fc
1300 psi
Fc'
355.15 psi
E
1.3 msi
E'
1.3 msi
Emin
0.47 msi
Emin'
0.47 msi
Selected Member: HF #2 3 x 5.5
b d
Member properties: Variables:
Section Modulus (d): 15.1 in" 3 Rb(d) 3.09
Section Modulus (b): 8.3 inA3 Rb(b) 7.66
Section Area: 16.5 inA2 c 0.8
Member stresses: Provided
Required
FcE(d) 1268 psi >
fc
351 psi
OK
FcE(b) 377 psi >
fc
351 psi
OK
FbE 9614 psi >
fb(d)
0 psi
OK
FbE 9614 psi >
fb(b)
0 psi
OK
Bending and Axial Compression Check:
NDS 2018 EQ 3.9-3 0.98
<
1.0
OK
John S. Apolis, P.E. CSES, Inc. Job number: 2022.151
Project: Lane Residence Date: 8-Feb-23
Architect: Michael Schoffner Page number: R15
Post Design (Combined Axial and Moment Loading)
2018 International Building Code (IBC) 2018 NDS
Post Description: Existing North GLB Support Posts
Snow Load: 1 Wind Load:
Repetitive Member: P.T. Lumber:
Geometry and loads:
Height
8 ft
w(d)
0 plf M(d)
Axial Load
8005 lbs
w(b)
0 plf M(b) 0 ft-lbs
Le(d)
8 ft
Le(b)
8 ft
Material Properties:
Fbl
675 psi
Fb(d)'
776.25 psi
Fb2
675 psi
Fb(b)'
776.25 psi
Fc
1300 psi
Fc'
716.83 psi
E
1.3 msi
E'
1.3 msi
Emin
0.47 msi
Emin'
0.47 msi
Selected Member: HF #2 4.5 x 5.5
b d
Member properties: Variables:
Section Modulus (d): 22.7 in" 3 Rb(d) 3.78
Section Modulus (b): 18.6 inA3 Rb(b) 5.11
Section Area: 24.8 inA2 c 0.8
Member stresses: Provided
Required
FcE(d) 1268 psi >
fc
323 psi
OK
FcE(b) 849 psi >
fc
323 psi
OK
FbE 21631 psi >
fb(d)
0 psi
OK
FbE 21631 psi >
fb(b)
0 psi
OK
Bending and Axial Compression Check:
NDS 2018 EQ 3.9-3 0.20
<
1.0
OK
.IFORTEWEB
Roof, R16: New South Cantilever Beam
1 piece(s) 4 x 10 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2451 @ 4' 1 3/4"
5206 (3.50")
Passed (47%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1195 @ 5' 3/4"
4468
Passed (27%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
2215 @ 9' 7 5/16"
5166
Passed (43%)
1.15
1.0 D + 1.0 S (Alt Spans)
Live Load Defl. (in)
0.063 @ 9' 2 1/16"
0.323
Passed (L/999+)
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.093 @ 9' 3 3/16"
0.484
Passed (L/999+)
1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
$ Available Required
Loads to Supports (Ibs)
Accessories
Dead
Snow
Factored
1 - Stud wall - SPF 3.50"
3.50"
1.65"
970
1482
2451
Blocking
2 - Stud wall - SPF 3.50"
3.50"
1.50"
405
685
1090
Blocking
• 1:51OcKmg vaneis are assumes io carry no ioaas appuea Direcoy aoove mem ano me Tuu ioaa is appuea co cne memoer Demg Designeo.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
14' o/c
Bottom Edge (Lu)
14' o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 14'
N/A
8.2
--
1 - Uniform (PSF)
0 to 14' (Top)
6'
15.0
25.0
Default Load
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Member Pitch : 0/12
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Weyerhaeuser
Job Notes
William Nocka
CSES
(978) 503-9935
llwnocka@gmail.com
R16
.IFORTEWEB
Roof, R17: South Roof Joists
1 piece(s) 2 x 6 HF No.2 @ 24" OC
PASSED
6.51 '
i
a a
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Member Length : 4' 3 7/8"
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
277 @ 1' 7 3/4"
2418 (3.50")
Passed (11%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
92 @ 2' 2 5/16"
949
Passed (10%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
-114 @ 1' 7 3/4"
921
Passed (12%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.008 @ 0
0.200
Passed (2L/999+)
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.014 @ 0
0.250
Passed (2L/999+)
1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Overhang deflection criteria: LL (0.2") and TL (2L/180).
• Left cantilever length exceeds 1/3 member length or 1/2 back span length. Additional bracing should be considered.
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A 15% increase in the moment capacity has been added to account for repetitive member usage.
• Applicable calculations are based on Nos.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Beveled Plate - SPF
3.50"
3.50"
1.50"
112
165
277
Blocking
2 - Beveled Plate - SPF
3.50"
3.50"
1.50"
10
34/-12
44/-2
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
4' 1" o/c
Bottom Edge (Lu)
4' 1" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Load
Location (Side)
Spacing
Dead
(0.90)
Snow
(1.15)
Comments
1 - Uniform (PSF)
0 to 3' 7"
24"
15.0
25.0
Default Load
System : Roof
Member Type : Joist
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Member Pitch : 6.5/12
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Weyerhaeuser
Job Notes
William Nocka
CSES
(978) 503-9935
llwnocka@gmail.com
R17
.IFORTEWEB
PASSED
0
12
2.47 1
Roof, R18: South East Hip Beam
1 piece(s) 2 x 6 HF No.2
Sloped Length: 10' 1 5/16'
r
2' 9 15/16" �. 7' 7/8"
Ll I a
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
358 @ 2' 11 11/16"
2171 (3.50")
Passed (17%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
214 @ 9' 1 15/16"
949
Passed (23%)
1.15
1.0 D + 1.0 S (Alt Spans)
Moment (Ft-Ibs)
351 @ 7' 1"
801
Passed (44%)
1.15
1.0 D + 1.0 S (Alt Spans)
Live Load Defl. (in)
0.070 @ 6' 6 3/4"
0.230
Passed (L/999+)
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
1 0.101 @ 6' 7 1/4"
0.345
Passed (L/819)
1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on Nos.
Bearing Length
Supports Available Required
Loads to Supports (Ibs)
Accessories
Dead
Snow
Factored
1 - Beveled Plate - SPF 3.50"
3.50"
1.50"
141
218
358
Blocking
2 - Beveled Plate - SPF 3.50"
3.50"
1.50"
107
203
310
Blocking
• 1:5100Kmg vaneis are assumes io carry no ioaas appuea airecoy aoove mem ano me Tuu ioaa is appuea co me memoer oemg oesigneo.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
10' 1" o/c
Bottom Edge (Lu)
10' 1" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 9' 10 13/16"
N/A
2.1
1 - Tapered (PLF)
0 to 2' 9 15/16"
N/A
0.0 to 43.3
0.0 to 70.7
Generated from
Roof Geometry
2 - Tapered (PLF)
2' 9 15/16" to 9' 10 13/16"
N/A
0.0 to 45.4
0.0 to 88.4
Generated from
Roof Geometry
Member Length : 10' 2 7/16"
System : Roof
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Member Pitch : 2.47/12
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
William Nocka
CSES
(978) 503-9935
llwnocka@gmail.com
A
Weyerhaeuser
R18
.IFORTEWEB
Roof, R19: East Roof Joists
1 piece(s) 2 x 6 HF No.2 @ 24" OC
PASSED
- +
0
1�
3.5
- i b
1
u o
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Member Length : 8' 3/8"
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
423 @ 2' 1 3/4"
2215 (3.50")
Passed (19%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
201 @ 2' 8 3/4"
949
Passed (21%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
217 @ 5' 13/16"
921
Passed (24%)
1.15
1.0 D + 1.0 S (Alt Spans)
Live Load Defl. (in)
0.027 @ 4' 10 1/4"
0.182
Passed (L/999+)
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.040 @ 4' 10 3/4"
0.272
Passed (L/999+)
1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A 15% increase in the moment capacity has been added to account for repetitive member usage.
• Applicable calculations are based on Nos.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
now
Factored
1 - Beveled Plate - SPF
3.50"
3.50"
1.50"
163
260
423
Blocking
2 - Beveled Plate - SPF
3.50"
3.50"
1 1.50"
74
130
205
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
7' 11" o/c
Bottom Edge (Lu)
7' 11" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Load
Location (Side)
Spacing
Dead
(0.90)
Snow
(1.15)
Comments
1 - Uniform (PSF)
0 to 7' 7"
24"
15.0
25.0
Default Load
System : Roof
Member Type : Joist
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Member Pitch : 3.5/12
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Weyerhaeuser
Job Notes
William Nocka
CSES
(978) 503-9935
llwnocka@gmail.com
R19
.IFORTEWEB
Roof, R20: South East Drop Beam
1 piece(s) 4 x 10 DF No.2
PASSED
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1408 @ 11' 10"
5206 (3.50")
Passed (27%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1159 @ 1' 3/4"
4468
Passed (26%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
3993 @ 6'
5166
Passed (77%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.147 @ 6'
0.583
Passed (L/954)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.265 @ 6'
0.778
Passed (L/529)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on Nos.
Bearing Length
Supports Available Required
Loads to Supports (Ibs)
Accessories
Dead
Roof Live
Snow
Factored
1 - Column - SPF 3.50"
3.50"
1.50"
769
120
998
1767
Blocking
2 - Stud wall - SPF 3.50"
3.50"
1.50"
628
120
780
1 1408
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
12' o/c
Bottom Edge (Lu)
12' o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Roof Live
Snow
Vertical Loads '
Location (Side)
Tributary Width
(0.90)
(non -snow: 1.00)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 12'
N/A
8.2
1 - Uniform (PSF)
0 to 12' (Front)
1'
15.0
20.0
-
Default Load
Linked from: R18:
2 - Point (lb)
0 (Top)
N/A
141
-
218
South East Hip
Beam, Support 1
Linked from: R19:
3 - Uniform (PLF)
0 to 12' (Top)
N/A
81.5
130.0
East Roof Joists,
Support 1
Notes
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Member Pitch : 0/12
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Weyerhaeuser
Job Notes
William Nocka
CSES
(978) 503-9935
llwnocka@gmail.com
R20
John S. Apolis, P.E. CSES, Inc. Job number: 2022.151
Project: Lane Residence Date: 8-Feb-23
Architect: Michael Schoffner Page number: R21
Post Design (Combined Axial and Moment Loading)
2018 International Building Code (IBC) 2018 NDS
Post Description: South East Deck Post
Snow Load: 1 Wind Load:
Repetitive Member: P.T. Lumber: 1
Geometry and loads:
Height
8 ft
w(d)
0 plf M(d)
Axial Load
2000 lbs
w(b)
0 plf M(b) 0 ft-lbs
Le(d)
8 ft
Le(b)
8 ft
Material Properties:
Fbl
900 psi
Fb(d)'
1035 psi
Fb2
900 psi
Fb(b)'
1035 psi
Fc
1350 psi
Fc'
568.13 psi
E
1.6 msi
E'
1.6 msi
Emin
0.58 msi
Emin'
0.58 msi
Selected Member: DF #2 3.5 x 3.5
b d
Member properties: Variables:
Section Modulus (d): 7.1 in^3 Rb(d) 5.24
Section Modulus (b): 7.1 in^3 Rb(b) 5.24
Section Area: 12.3 in^2 c 0.8
Member stresses: Provided
Required
FcE(d) 634 psi >
fc
163 psi
OK
FcE(b) 634 psi >
fc
163 psi
OK
FbE 25375 psi >
fb(d)
0 psi
OK
FbE 25375 psi >
fb(b)
0 psi
OK
Bending and Axial Compression Check:
NDS 2018 EQ 3.9-3 0.08
<
1.0
OK
.IFORTEWEB
Roof, R22: New French Door Header
2 piece(s) 2 x 8 HF No.2
PASSED
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
C
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
626 @ 0
1823 (1.50")
Passed (34%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
506 @ 8 3/4"
2501
Passed (20%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
922 @ 2'
2569
Passed (36%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.022 @ 2' 6 15/16"
0.131
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.035 @ 2' 6 15/16"
0.262
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/480) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports FF
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Trimmer - HF
1.50"
1.50"
1.50"
238
388
626
None
2 - Trimmer - HF
1.50"
1.50"
1 1.50"
213
340
553
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
5' 3" o/c
Bottom Edge (Lu)
5' 3" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 5' 3"
N/A
5.5
--
1 - Uniform (PSF)
0 to 5' 3"
4'
15.0
25.0
Default Load
Linked from: R18:
2 - Point (lb)
2'
N/A
107
203
South East Hip
Beam, Support 2
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Weyerhaeuser
Job Notes
William Nocka
CSES
(978) 503-9935
llwnocka@gmail.com
R22
John S. Apolis, P.E. CSES, Inc. Job number: 2022.151
Project: Lane Date: 17-Nov-23
Architect: Page number: R23
BEAM DESIGN (Uniform Load+Concentrated Load)
2018 International Building Code (IBC) 2018 NDS
Beam Description: South Support of R10
Fully Supported: Snow Load: 1 Wind Load:
Repetitive Member: P.T. Lumber: Wet Use:
Geometry and Loads:
Span: 8.75 ft Tributary Width: 20 ft P Location: 6 ft
Add'l uniform DL: DL unit load: 15 psf Concentrated DL: 2662 lbs
Add'l uniform LL: LL unit load: Concentrated LL:
Add'l uniform SL: SL unit load: 25 psf Concentrated SL: 3836 lbs
Add'l uniform WL: WL unit load: Concentrated WL:
DL Reaction 1:
3138 lbs
DL Reaction 2:
2149 lbs
Note: Design automatically uses
LL Reaction 1:
0 lbs
LL Reaction 2:
0 lbs
ASD load combinations
SL Reaction 1:
4818 lbs
SL Reaction 2:
3393 lbs
WL Reaction 1:
0 lbs
WL Reaction 2:
0 lbs
Total Reaction 1:
7956 lbs
Total Reaction 2:
5542 lbs
Material Properties:
E
2 msi
E'
2 msi
Fb
2900 psi
Fb'
3433 psi
Fv
290 psi
Fv'
334 psi
Fc perp
625 psi
Fc perp'
625 psi
Emin
0.914 msi
Emin'
0.914 msi
Deflection analysis:
For total
load: Allowed deflection criteria, span/
240
For LL
only: Allowed deflection criteria, span/
360
Max. allowed total defl:
0.44 in
Max LL defl:
0.29 in
Total defl. * I:
117.63 inA4
Required I:
268.88 inA4
LL defl. * 1:
71.27 inA4
Required 1:
244.36 inA4
Actual deflections:
TOTAL:
0.34 in
0.21 in
Force analysis:
Max. moment: 18853 ft-lb
Max Shear: 7956 lbs
Selected Member: (1) PSL 5.25 x 9.25
Member properties:
Provided:
Required:
Moment of inertia:
346.26 inA4
268.88 inA4
Section Modulus:
74.87 in^3
65.91 inA3
Section Area:
48.56 in^2
35.78 in^2
Bearing Area:
12.73 inA2
Minimum bearing dimensions:
5.25 in x
2.42 in
John S. Apolis, P.E. CSES, Inc. Job number: 2022.151
Project: Lane Date: 17-Nov-23
Architect: Page number: R24
BEAM DESIGN (Uniform Load+Concentrated Load)
2018 International Building Code (IBC) 2018 NDS
Beam Description: North and South Headers @ New Truss Roof
Fully Supported: Snow Load: 1 Wind Load:
Repetitive Member: P.T. Lumber: Wet Use:
Geometry and Loads:
Span: 4.5 ft Tributary Width: 20 ft P Location: 4.5 ft
Add'l uniform DL: DL unit load: 15 psf Concentrated DL:
Add'l uniform LL: LL unit load: Concentrated LL:
Add'l uniform SL: SL unit load: 25 psf Concentrated SL:
Add'l uniform WL: WL unit load: Concentrated WL:
DL Reaction 1:
675 lbs
DL Reaction 2:
675 lbs
Note: Design automatically uses
LL Reaction 1:
0 lbs
LL Reaction 2:
0 lbs
ASD load combinations
SL Reaction 1:
1125 lbs
SL Reaction 2:
1125 lbs
WL Reaction 1:
0 lbs
WL Reaction 2:
0 lbs
Total Reaction 1:
1800 lbs
Total Reaction 2:
1800 lbs
Material Properties:
E
1.3 msi
E'
1.3 msi
Fb
850 psi
Fb'
1173 psi
Fv
150 psi
Fv'
173 psi
Fc perp
405 psi
Fc perp'
405 psi
Emin
0.47 msi
Emin'
0.47 msi
Deflection analysis:
For total load: Allowed deflection criteria, span/
240
For LL only: Allowed deflection criteria, span/
360
Max. allowed total defl:
0.23 in
Max LL defl:
0.15 in
Total defl. * I:
5.68 inA4
Required I:
25.23 in^4
LL defl. * 1:
3.55 inA4
Required I:
23.66 inA4
Actual deflections:
TOTAL:
0.06 in
0.04 in
Force analysis:
Max. moment: 2025 ft-lb
Max Shear: 1800 lbs
Selected Member: (2) H F #2 1.5 x 7.25
Member properties:
Provided:
Required:
Moment of inertia:
95.27 in^4
25.23 in^4
Section Modulus:
26.28 in^3
20.72 inA3
Section Area:
21.75 in^2
15.65 in^2
Bearing Area:
4.44 inA2
Minimum bearing dimensions:
3. in x
1.48 in
John S. Apolis, P.E. CSES, Inc. Job number: 2022.151
Project: Lane Residence Date: 8-Feb-23
Architect: Michael Schoffner Page number: R25
Post Design (Combined Axial and Moment Loading)
2018 International Building Code (IBC) 2018 NDS
Post Description: Beam R23 Supports
Snow Load: 1 Wind Load:
Repetitive Member: P.T. Lumber:
Geometry and loads:
Height
8 ft
w(d)
0 plf M(d)
Axial Load
5387 lbs
w(b)
0 plf M(b) 0 ft-lbs
Le(d)
8 ft
Le(b)
8 ft
Material Properties:
Fbl
900 psi
Fb(d)'
1035 psi
Fb2
900 psi
Fb(b)'
1035 psi
Fc
1350 psi
Fc'
568.13 psi
E
1.6 msi
E'
1.6 msi
Emin
0.58 msi
Emin'
0.58 msi
Selected Member: DF #2 3.5 x 5.5
b d
Member properties: Variables:
Section Modulus (d): 17.6 in^3 Rb(d) 3.33
Section Modulus (b): 11.2 in^3 Rb(b) 6.57
Section Area: 19.3 in^2 c 0.8
Member stresses: Provided
Required
FcE(d) 1565 psi >
fc
280 psi
OK
FcE(b) 634 psi >
fc
280 psi
OK
FbE 16148 psi >
fb(d)
0 psi
OK
FbE 16148 psi >
fb(b)
0 psi
OK
Bending and Axial Compression Check:
NDS 2018 EQ 3.9-3 0.24
<
1.0
OK
.IFORTEWEB
PASSED
Roof, R26: Replacement Hip @ South Roof
1 piece(s) 4 x 10 DF No.2
Sloped Length: 10 67/16
r
4.6
5' 7 7/8 3' 10 11/16"
❑1 20
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Member Length : 10' 61/4"
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2482 @ 5' 9 5/8"
5576 (3.50")
Passed (45%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1136 @ 6' 8"
4468
Passed (25%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
-2792 @ 5' 9 5/8"
5166
Passed (54%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.128 @ 0
0.621
Passed (2L/999+)
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.214 @ 0
0.829
Passed (2L/696)
1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Overhang deflection criteria: LL (2L/240) and TL (2L/180).
• Left cantilever length exceeds 1/3 member length or 1/2 back span length. Additional bracing should be considered.
• Allowed moment does not reflect the adjustment for the beam stability factor.
• -228 Ibs uplift at support located at 9' 6 9/16". Strapping or other restraint may be required.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Beveled Plate - SPF
3.50"
3.50"
1.56"
1030
1452
2482
Blocking
2 - Hanger on 9 1/4" SPF beam
3.50"
Hangers
1.50"
-12
221/-216
209/-228
See note '
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
10' 3" o/c
Bottom Edge (Lu)
10' 3" o/c
-Maximum allowable bracing intervals based on applied load.
System : Roof
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Member Pitch : 4.6/12
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
2 - Face Mount Hanger
LSSR41OZ
1.88"
N/A
22-16dx2.5
18-16dx2.5
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 9' 6 9/16"
N/A
8.2
1 - Tapered (PLF)
0 to T 7 7/8"
N/A
5.0 to 49.0
17.0 to 74.0
Joists Below
2 - Tapered (PLF)
5' 7 7/8" to 9' 6 9/16"
N/A
113.0 to 143.0
188.0 to 238.0
Generated from
Roof Geometry
3 - Tapered (PSF)
0 to 9' 10 1/16"
T to 0
15.0
25.0
ForteWEB Software Operator
Weyerhaeuser
Job Notes
William Nocka
CSES
(978) 503-9935
llwnocka@gmail.com
R26
.IFORTEWEB
Roof, R27: Header Below R26
1 piece(s) 4 x 8 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2150 @ 0
3281 (1.50")
Passed (66%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1145 @ 8 3/4"
3502
Passed (33%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
1064 @ 6"
3438
Passed (31%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.004 @ 1' 3 3/8"
0.092
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.006 @ 1' 3 7/16"
0.138
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Trimmer - HF
1.50"
1.50"
1.50"
893
1257
2150
None
2 - Trimmer - HF
1.50"
1.50"
1 1.50"
237
333
570
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
2' 9" o/c
Bottom Edge (Lu)
2' 9" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 2' 9"
N/A
6.4
1 - Uniform (PSF)
0 to 2' 9"
2'
15.0
25.0
Default Load
Linked from: R26:
2 - Point (lb)
6"
N/A
1030
1452
Replacement Hip @
South Roof,
Support 1
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Weyerhaeuser
Job Notes
William Nocka
CSES
(978) 503-9935
llwnocka@gmail.com
R27
John S. Apolis, P.E. CSES, Inc. Job number: 2022.151
Project: Lane Residence Date: 8-Feb-23
Architect: Michael Schoffner Page number: M1
Post Design (Combined Axial and Moment Loading)
2018 International Building Code (IBC) 2018 NDS
Post Description: Post Either Side of West Door Header
Snow Load: 1 Wind Load:
Repetitive Member: P.T. Lumber:
Geometry and loads:
Height
8 ft
w(d)
0 plf M(d)
Axial Load
3984 lbs
w(b)
0 plf M(b) 0 ft-lbs
Le(d)
8 ft
Le(b)
0.5 ft
Material Properties:
Fbl
850 psi
Fb(d)'
977.5 psi
Fb2
850 psi
Fb(b)'
977.5 psi
Fc
1300 psi
Fc'
944.28 psi
E
1.3 msi
E'
1.3 msi
Emin
0.47 msi
Emin'
0.47 msi
Selected Member: HF #2 3 x 5.5
b d
Member properties: Variables:
Section Modulus (d): 15.1 in" 3 Rb(d) 3.09
Section Modulus (b): 8.3 inA3 Rb(b) 1.91
Section Area: 16.5 inA2 c 0.8
Member stresses: Provided
Required
FcE(d) 1268 psi >
fc
241 psi
OK
FcE(b) 96585 psi >
fc
241 psi
OK
FbE 59240 psi >
fb(d)
0 psi
OK
FbE 59240 psi >
fb(b)
0 psi
OK
Bending and Axial Compression Check:
NDS 2018 EQ 3.9-3 0.07
<
1.0
OK
John S. Apolis, P.E. CSES, Inc. Job number: 2022.151
Project: Lane Residence Date: 8-Feb-23
Architect: Michael Schoffner Pate number: NV12
BEAM DESIGN (Uniform Load+Concentrated Load)
2018 International Building Code (IBC) 2018 NDS
Beam Description: South West Existing Header
Fully Supported: � Snow Load: � Wind Load:
Repetitive Member: P.T. Lumber: Wet Use:
Geometry and Loads:
Span: 13 ft Tributary Width: 9 ft P Location: 3.833 ft
Add'l uniform DL: 106 lbs/ft DL unit load: 12 psf Concentrated DL:
Add'l uniform LL: 210 lbs/ft LL unit load: 40 psf Concentrated LL:
Add'l uniform SL: SL unit load: Concentrated SL:
Add'l uniform WL: WL unit load: Concentrated WL:
DL Reaction 1:
1391 lbs
DL Reaction 2:
1391 lbs Note: Design automatically uses
LL Reaction 1:
3705 lbs
LL Reaction 2:
3705 lbs ASD load combinations
SL Reaction 1:
0 lbs
SL Reaction 2:
0 lbs
WL Reaction 1:
0 lbs
WL Reaction 2:
0 lbs
Total Reaction 1:
5096 lbs
Total Reaction 2:
5096 lbs
Material Properties:
E
1.8 msi
E'
1.8 msi
Fb
2400 psi
Fb'
2760 psi
Fv
265 psi
Fv'
305 psi
Fc perp
650 psi
Fc perp'
650 psi
Emin
0.95 msi
Emin'
0.95 msi
Deflection analysis:
For total load: Allowed deflection criteria,
span/ 240
For LL only:
Allowed deflection criteria,
span/ 480
Max. allowed total defl:
0.65 in
Max LL defl:
0.33 in
Total defl. * I:
279.9 inA4
Required 1:
430.61 in^4
LL defl. * I:
203.5 inA4
Required 1:
626.15 in^4
Actual deflections:
TOTAL:
0.71 in
0.52 in
Force analysis:
Max. moment: 16562 ft-lb Max Shear: 5096 lbs
Selected Member (1) GLB 5.5 x 9.5
Member properties:
Provided:
Required:
Moment of inertia:
392.96 in^4
626.15 in^4
Section Modulus:
82.73 in^3
72.01 in^3
Section Area:
52.25 in^2
25.08 in^2
Bearing Area:
7.84 in^2
Minimum bearing dimensions:
5.5 in x
1.43 in
.IFORTEWEB
Main Floor, MI Existing North Floor Flush Beam
1 piece(s) 5 1/2" x 16 1/2" 24F-V4 DF Glulam
PASSED
I�
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
17
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
4145 @ 16' 1"
12251 (5.50")
Passed (34%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
3885 @ 14' 7"
18437
Passed (21%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Pos Moment (Ft-Ibs)
11148 @ 12'
49409
Passed (23%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.066 @ 8' 11 7/16"
0.394
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.137 @ 8' 9 11/16"
0.788
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/480) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 0.99 that was calculated using length L = 15' 9".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports *
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Factored
1 -Stud wall - HF
5.50"
4.00"
1.50"
1141
769
304
1946
1 1/2" Rim Board
2 - Stud wall - HF
5.50"
5.50"
1.86"
2067
1385
1386
4145
Blocking
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
164" o/c
Bottom Edge (Lu)
164" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
1 1/2" to 165"
N/A
22.1
1 - Uniform (PSF)
0 to 16' 5" (Front)
1' 3 15/16"
12.0
40.0
Default Load
2 - Point (lb)
12' (Front)
N/A
384
1280
3 - Uniform (PSF)
0 to 16' 5" (Front)
8'
8.0
-
4 - Point (lb)
13' 3" (Top)
N/A
1152
1690
Linked from: R12:
Existing North GLB,
Support 1
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Weyerhaeuser
Job Notes
William Nocka
CSES
(978) 503-9935
llwnocka@gmail.com
M3
.IFORTEWEB
Main Floor, M4: Existing South Floor Flush Beam
1 piece(s) 5 1/2" x 16 1/2" 24F-V4 DF Glulam
PASSED
I�
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
17
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3411 @ 16' 1"
12251 (5.50")
Passed (28%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
2832 @ 14' 7"
16033
Passed (18%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
10641 @ 12'
49409
Passed (22%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.060 @ 8' 10 7/8"
0.394
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.126 @ 8' 9 1/16"
0.788
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/480) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 0.99 that was calculated using length L = 15' 9".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on Nos.
Supports *
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Factored
1 -Stud wall - HF
5.50"
4.00"
1.50"
1098
769
229
1867
1 1/2" Rim Board
2 - Stud wall - HF
5.50"
5.50"
1.53"
1732
1385
854
3411
Blocking
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
164" o/c
Bottom Edge (Lu)
164" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
1 1/2" to 165"
N/A
22.1
1 - Uniform (PSF)
0 to 16' 5" (Front)
1' 3 15/16"
12.0
40.0
Default Load
2 - Point (lb)
12' (Front)
N/A
384
1280
3 - Uniform (PSF)
0 to 16' 5" (Front)
8'
8.0
-
4 - Point (lb)
12' 9" (Top)
N/A
774
1083
Linked from: R13:
Existing South GLB,
Support 1
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Weyerhaeuser
Job Notes
William Nocka
CSES
(978) 503-9935
llwnocka@gmail.com
AU
John S. Apolis, P.E. CSES, Inc. Job number: 2022.151
Project: Lane Residence Date: 8-Feb-23
Architect: Michael Schoffner Page number: M5
Post Design (Combined Axial and Moment Loading)
2018 International Building Code (IBC) 2018 NDS
Post Description: Post @ East End of Existing North Flush Beam
Snow Load: 1 Wind Load:
Repetitive Member: P.T. Lumber:
Geometry and loads:
Height
8 ft
w(d)
0 plf M(d)
Axial Load
11892 lbs
w(b)
0 plf M(b) 0 ft-lbs
Le(d)
8 ft
Le(b)
8 ft
Material Properties:
Fbl
675 psi
Fb(d)'
776.25 psi
Fb2
675 psi
Fb(b)'
776.25 psi
Fc
1300 psi
Fc'
716.83 psi
E
1.3 msi
E'
1.3 msi
Emin
0.47 msi
Emin'
0.47 msi
Selected Member: HF #2 4.5 x 5.5
b d
Member properties: Variables:
Section Modulus (d): 22.7 in" 3 Rb(d) 3.78
Section Modulus (b): 18.6 inA3 Rb(b) 5.11
Section Area: 24.8 inA2 c 0.8
Member stresses: Provided
Required
FcE(d) 1268 psi >
fc
480 psi
OK
FcE(b) 849 psi >
fc
480 psi
OK
FbE 21631 psi >
fb(d)
0 psi
OK
FbE 21631 psi >
fb(b)
0 psi
OK
Bending and Axial Compression Check:
NDS 2018 EQ 3.9-3 0.45
<
1.0
OK
John S. Apolis, P.E. CSES, Inc. Job number: 2022.151
Project: Lane Residence Date: 8-Feb-23
Architect: Michael Schoffner Page number: M6
Post Design (Combined Axial and Moment Loading)
2018 International Building Code (IBC) 2018 NDS
Post Description: Post in Crawl Space, Worst Case
Snow Load: 1 Wind Load:
Repetitive Member: P.T. Lumber:
Geometry and loads:
Height
4 ft
w(d)
0 plf M(d)
Axial Load
11892 lbs
w(b)
0 plf M(b) 0 ft-lbs
Le(d)
4 ft
Le(b)
4 ft
Material Properties:
Fbl
900 psi
Fb(d)'
1035 psi
Fb2
900 psi
Fb(b)'
1035 psi
Fc
1350 psi
Fc'
1287 psi
E
1.6 msi
E'
1.6 msi
Emin
0.58 msi
Emin'
0.58 msi
Selected Member: DF #2 3.5 x 3.5
b d
Member properties: Variables:
Section Modulus (d): 7.1 in" 3 Rb(d) 3.70
Section Modulus (b): 7.1 in" 3 Rb(b) 3.70
Section Area: 12.3 inA2 c 0.8
Member stresses: Provided
Required
FcE(d) 2535 psi >
fc
971 psi
OK
FcE(b) 2535 psi >
fc
971 psi
OK
FbE 50750 psi >
fb(d)
0 psi
OK
FbE 50750 psi >
fb(b)
0 psi
OK
Bending and Axial Compression Check:
NDS 2018 EQ 3.9-3 0.57
<
1.0
OK
aFORTEWEB'
Main Floor, M7: Header Below New Sliders
3 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam@ LVL
PASSED
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
C
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
4326 @ 0
5709 (1.50")
Passed (76%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
3386 @ 1' 1 3/8"
11845
Passed (29%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
11087 @ 5' 1 1/2"
26772
Passed (41%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.116 @ 5' 1 1/2"
0.171
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.164 @ 5' 1 1/2"
0.512
Passed (L/752)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/720) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Factored
1 - Trimmer - HF
1.50"
1.50"
1.50"
1251
3075
256
4326
None
2 - Trimmer - H F
1.50"
1.50"
1.50"
1251
3075
256
4326
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
10' 3" o/c
Bottom Edge (Lu)
10' 3" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 10' 3"
N/A
18.2
1 - Uniform (PSF)
0 to 10' 3"
4'
12.0
60.0
Default Load
2 - Uniform (PLF)
0 to 10' 3"
N/A
40.0
-
-
3 - Uniform (PSF)
0 to 10' 3"
2'
15.0
25.0
4 - Uniform (PSF)
0 to 10' 3"
9'
12.0
40.0
1 -
rhaeuser Notes
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Weyerhaeuser
Job Notes
William Nocka
CSES
(978) 503-9935
llwnocka@gmail.com
M7
aFORTEWEB'
Main Floor, M8: Header Below New Middle Door
1 piece(s) 6 x 10 DF No.2
PASSED
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
C
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2623 @ 0
5156 (1.50")
Passed (51%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
1853 @ 11"
5922
Passed (31%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
4098 @ 3' 1 1/2"
6032
Passed (68%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.040 @ 3' 1 1/2"
0.104
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.056 @ 3' 1 1/2"
0.313
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/720) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Lumber grading provisions must be extended over the length of the member per NDS 4.2.5.5.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Factored
1 - Trimmer - HF
1.50"
1.50"
1.50"
748
1875
156
2623
None
2 - Trimmer - HF
1.50"
1.50"
1.50"
748
1875
156
2623
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
6' 3" o/c
Bottom Edge (Lu)
6' 3" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF) 0 to 6' 3"
N/A
13.2
1 - Uniform (PSF) 0 to 6' 3"
4'
12.0
60.0
Default Load
2 - Uniform (PLF) 0 to 6' 3"
N/A
40.0
-
3 -Uniform (PSF) 0 to 6' 3"
2'
15.0
25.0
4 - Uniform (PSF) 0 to 6' 3"
9'
12.0
40.0
1 -
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser Notes RP 0 0
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Weyerhaeuser
Job Notes
William Nocka
CSES
(978) 503-9935
llwnocka@gmail.com
•
. . . . . . .. . . . ........
.. ........ ......... . . . . . . . .......... . ..... . ........ ....... ................ ......... S ........ I ................. ................. .... .............
.... ............... .................................. .... . ........ ........
...........
........ ..... . ..... .... ... ........
.................. ......................... ..... .......
CA 6
u... ....... .......... !/ tA.L1) ..... .......... ... .... ................. ........
. ............... ........... ................
. . . .. . .. ........ ........ ........ ........ ....... ........
.. ......... ........ ........ ........ ........ ...... ..... .... ..... ............................ ; .......
............... ........ S ....... .....
.... . ...... ............... . ........... ......... ................. ....... .......
........... ...............
..... ...... ........
•
............... .... .. .. .... .... .. ..... ........ ......................... . ................. ........ ....... ...... ....... .. ....... .................. .......
............. .... .. ......................................... ........ ................. ....... ........ ....... ........ ........
. . . ........ ............. ... ........ ........ ........ ........ .........
........ . .......... ... . .. .............. ....... ....... ........ ........
.................. ........ .. ..... ........ .... .......... . .. . . ...... ........ ........ ........ ........ ........ ........
................................... .. ....... ...... ... ................ .. ........ ........ ........ ....... . . ..... ........
..... ........ ................. ....... ........ . ..... ........ ........ ........ ........ ....... ................. ..... ........ I .... .. ........
.............. ............. ................. ................. ........ ...... ........ ........ ....... ........ .................
.......................... ........ . ......
................. ................ .............. ................... . ..... ........ ....... ....... ........ ........ i ...... i ....... 4 ................................... ........ ........ ........ ... ....... ....... ........ ........
............. ................. ........ ........ ........ ...... ........
.... . ... ....... .. ........ ... .......
.. ........ 1 4 ........ ........ ........ .......
. ............ ............. .... .
CONSULTING STRUCTURAL ENGINEERING SERVICES
Residential and Commercial Structural Design
6311 17th Avenue NE, Seattle, WA 98115
Phone: (206)527-1288 Email: john(!,)csL-s-eiigiiit-L-riiig.coni
...........
.. . ........
....Y.......... .. .............
. ..... . .. . .. . ......
........... V.
Project No. Z=*Z -151 — Date I — 14, —23
Project Name "PC
Comments
Revision
Page L-42k1
John S. Apolis, P.E. CSES, Inc. Job number: 2022.151
Project: Lane Residence Date: 8-Feb-23
Architect: Michael Schoffner Page number: L1
Lateral Loads Design per ASCE 7-16, Wind: Section 28 Seismic: Section 12
(Simplified Envelope Procedure Part 2) 2015 & 2018 International Building Code (IBC)
WIND LOADS 110 mph Basic Wind Speed 2018 NDS
Ps = lambda * Kzt * Ps(30) * 0.6 Exposure B Roof Slope: 1.00 :12 = 4.8
Least Horizontal Dimension, feet: 56 Mean Roof Ht, feet: 25 (degrees)
lambda =
1.00
a =
5.6
ft, 2a =
11.2
ft
Iw =
1.00
KzT =
1.53
Tabulated
Calc'd
Min
(Per section 28.6.4
Wind
DesiEn
Design
minimum tabulated wind
Tabulated Ps(30):
Zone
Pressure
Pressure
Pressure
pressure is 16 PSF for
(Refer to ASCE 7-16, Figure 28.6-1)
(*lambda*KzT*0.6)
zonesA,C, and 8 PSF for
(horizontal)
A
19.2
psf
17.6
17.6
zones B, D)
"
B
-10.0
psf
-9.2
9.2
"
C
12.7
psf
11.7
14.7
it
D
-5.9
psf
-5.4
7.3
(vertical)
E
-23.1
psf
-21.2
it
F
-13.1
psf
-12.0
it
G
-16.0
psf
-14.7
"
H
-10.1
psf
-9.3
(uplift on overhangs)
E(oh)
-32.3
psf
-29.7
it
G(oh)
-25.3
psf
-23.2
(Equivalent Lateral Force Procedure, Section 12.8)
SEISMIC LOADS Ie 1.0 R = 6.5
ASCE 7-16, Table 12.2.1
Seismic Parameters Group I Site Class: D
per ASCE 7-16) PGA (.2 sec) 1.3060 Fa = 1.00
ASCE 7-16 Table 11.4-1
PGA (1 sec) 0.4530 Fv = 1.60
ASCE 7-16 Table 11.4-2
Seismic Design Categories per ASCE 7-16 Tables 11.6-1,11.6-2
Based on Sds: D Based on Shc:
D
PGA's based on peak ground accelerations per latest USGS Hazards Program
(based on lat/lon).
Ss = 1.3060 Sms = Fa * Ss =
1.31 Equation 11.4-1
S1 = 0.4530 Sml = Fv * S1 =
0.72 Equation 11.4-2
Equations 11.4-3, 11.4-4 Sds = 2/3 * Sms = 0.87 Shc = 2/3 * Sml = 0.48
Equation 12.14-11 Cs (%V) = (Sds / (R/1) ) = 0.134 Building period < 0.5 s per IBC eq 12.8-7
Base Shear = %V * W * 0.7 = 4.22 psf, uniformly distributed over floor area
(0.7 reduction factor per ASCE 7-16, Section 2.4.1, Eq (seismic vertical distribution per IBC eqs 12.8-11 & 12)
Roof DL Wall DL (Psf) Story Height Lateral
Base = top of foundation(psf) dist. over floor area Above Base (ft) Load s
Roof 15 6 20 2.69
Upper Floor 12 12 10 1.53
0.00
Total Seismic DL: 45 Sum 4.22
L-APE7ZAL- PeM.-f tJ - F_�F t_M4E�_-L
u cw 5H� 2 w14u. L 3x(2.s'), k
J'wz
pX_ =
4 x 41x ru'{sr—t- Z.s�x (1.2�xg2�tq �c'� Xj4•�t2�ic4'x -43f,-P
L . = •2S' + 7- "4 Z.S'4
t_
.... .......................... ..
.._....._ ....... .......
I%Sz0- + 8 X--o /x 1,15 4 ,r.
.. 2 _
�.� - .. .......
DEAD -*kD
.
..:.......�.............. ..............
. . . . . . . . . .
1
€ '• VG
CONSULTING STRUCTURAL ENGINEERING SERVICES
Residential and Commercial Structural Design
6311 17th Avenue NE, Seattle, WA 98115
Phone: (206)527-1288 Email: johnovses-engineering.com
Project No. 'ZO2Z• V Date 1 Z3
Project Name LANE
Comments
Revision
Page i�2