Loading...
REV1 REVIEWED BLD2023-0908+Energy_Calculations+2.6.2024_9.35.35_AM+4041889BLD2023-0908 REVISION Simple Heating System Size: Washington State Feb 06 2024 This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and CITY OF EDMONDS ACCA Manuals J and S. This tool will calculate heating loads only. ACCA for sizing cooling systems should be used to determine E ELOPMENT SERVICES procedures DEPARTMENT cooling loads. ................................................ REVIEWED Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each BY section, some values will be calculated for If do not see the selection need in the drop -down down options, lease contact the WSU TY i CIDING you. you you y y y p p p � BUILDING DEPARTMENT: DEPARTEDMONDMENT: Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance Project Information Contact Information Kean Addition WalIsand Weeds, Inc. 10533 243rd PI SW 110016 Edmonds Way#C229 Edmonds WA98020 I lEdmondsWA98020 Heating System Type: 0 All other systems 0 Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) Ed m o n d s Ell OT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 636 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.0 5,088 Glazing and Doors U-Factor X Area = UA Instructions U-0.30 - J 0.300 112 33.60 Skylights U-Factor X Area = UA Instructions 0.50 ® 4.00 Insulation Attic U-Factor X Area = UA Instructions R-49 Ell 0.026 636 16.54 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions Select R-Value No selection Above Grade Walls (see Figure1) U-Factor X Area UA Instructions ` a R-21 Intermediate - J 0.056 996 55.78 Floors U-Factor X Area UA Instructions R-30 F1 0.029 636 18.44 Below Grade Walls (see Figurel) U-Factor X Area UA Instructioi No Below Grade Walls in t - j 0.028 0 Slab Below Grade (see Figure 1) F-Factor X Length UA Instructions Select conditioning � No selection --- Slab on Grade (see Figure1) F-Factor X Length UA Instructions R-10 Fully Insulated 0.360 F 44 15.84 Location of Ducts Instructions Duct Leakage Coefficient Conditioned S ace R 1.00 Sum of UA 144.20 Fiaure 1. Above Grade 46 Envelope Heat Load 6,633 Btu / Hour Sum ofUAxAT Air Leakage Heat Load 2,528 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 9,161 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 9,161 Btu / Hour Ducts in unconditioned space: sum of buildina heat loss x 1.10 Ducts in conditioned space: sum of buildinq heat loss x 1 Maximum Heat Equipment Output 11,451 Btu / Hour Buildina and duct heat loss x 1.40 for forced air furnace Buildina and duct heat loss x 1.25 for heat oumo (07101113)