SEE REV1 REVIEWED RESUB1 BLD2023-0908+Energy_Calculations+10.6.2023_3.07.14_PM+3827075MINIY X$00I16:1 Simple heating System Size: wasnington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Prnipct Kean Addition WalIsand Weeds, Inc. 10533 243rd PI SW 10016 Edmonds Way#C229 Edmonds WA98020 Edmonds WA98020 Heating System Type: O All other systems `Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) Ed m o n d s Ell OT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 695 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.0 5,560 Glazing and Doors U-Factor X Area = UA Instructions U-0.30 - J 0.300 216 64.80 Skylights U-Factor X Area = UA Instructions 0.50 12 6.00 Insulation Attic U-Factor X Area = UA Instructions R-49 Ell 0.026 636 16.54 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions OR-49 Advanced 0.020 59 1.18 Above Grade Walls (see Figure1) U-Factor X Area UA Instructions ` a R-21 Intermediate - J 0.056 1,048 58.69 Floors U-Factor X Area UA Instructions R-30 F1 0.029 695 20.16 Below Grade Walls (see Figurel) U-Factor X Area UA Instructioi No Below Grade Walls in t - j 0.028 0 Slab Below Grade (see Figure 1) F-Factor X Length UA Instructions Select conditioning � No selection --- Slab on Grade (see Figure1) F-Factor X Length UA Instructions R-10 Fully Insulated 0.360 F 44 15.84 Location of Ducts Instructions Duct Leakage Coefficient Conditioned S ace R 1.00 Sum of UA 183.20 Figure 1. Above Grade 46 Envelope Heat Load 8,427 Btu / Hour Sum ofUAxAT Air Leakage Heat Load 2,762 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 11,189 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 11,189 Btu/Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of buildinq heat loss x 1 Maximum Heat Equipment Output 13,987 Btu / Hour Buildina and duct heat loss x 1.40 for forced air furnace Buildina and duct heat loss x 1.25 for heat oumo RESUB Oct 08 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT (07101113)