APPROVED BLD BLD2023-1461+STRUCTURAL PLANS+11.8.2023_3.12.54_PM+3889877STRUCTURAL NOTES CODE ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC) AS AMENDED BY THE LOCAL JURISDICTION. SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. DESIGN LOADS LIVE LOADS: RESIDENTIAL 40 PSF SNOW 25 PSF EARTHQUAKE LOADS: SITE CLASS D SHORT PERIOD SPECTRAL RESPONSE (SDS) 1.056 ONE SECOND SPECTRAL RESPONSE (Spy) 0.572 OCCUPANCY CATEGORY ll SEISMIC IMPORTANCE FACTOR (IE) 1.00 SEISMIC DESIGN CATEGORY D BASIC SEISMIC FORCE -RESISTING -SYSTEM WOOD S.W. RESPONSE MODIFICATION FACTOR, (R) 6.5 SEISMIC RESPONSE COEFFICIENT (CS) 0.162 WIND LOADS: ULT. BASIC WIND SPEED (3 SECOND GUST) 100 MPH EXPOSURE B KZT 1.00 SPECIAL INSPECTION SPECIAL INSPECTION SHALL BE PERFORMED PER CHAPTER 17 OF THE IBC ONLY WHERE REQUIRED BY THE LOCAL JURISDICTION FOR THE FOLLOWING ITEMS: • SOILS (SECTION/TABLE 1705.6) • CONCRETE (SECTION/TABLE1705.3) • WOOD (SECTION 1705.5) REFER TO IBC SECTION 1705.10 AND 1705.11 FOR ADDITIONAL INSPECTION REQUIREMENTS FOR THE STRUCTURAL COMPONENTS OF THE LATERAL FORCE RESISTING SYSTEM. ALL INSPECTIONS SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE OWNER. THE ARCHITECT, ENGINEER, AND BUILDING OFFICIAL SHALL BE FURNISHED WITH COPIES OF ALL INSPECTION REPORTS. IF ANY INSPECTION FAILS TO MEET THE REQUIREMENTS OF THE CONTRACT DOCUMENTS, IT SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE DESIGN TEAM. STRUCTURAL OBSERVATION STRUCTURAL OBSERVATION SHALL BE PERFORMED PER CHAPTER 17 OF THE IBC ONLY WHERE REQUIRED BY THE LOCAL JURISDITION. STRUCTURAL OBSERVATION DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY FOR ANY SPECIAL INSPECTIONS REQUIRED. NOTIFY THE ENGINEER A MINIMUM OF ONE WEEK PRIOR TO THE OBSERVATION. FOUNDATIONS: THE FOLLOWING SOIL DESIGN PARAMETERS HAVE BEEN ASSUMED. IF EXCAVATION SHOWS THAT SOIL CONDITIONS DO NOT MATCH THE LISTED DESIGN VALUES, A GEOTECHNICAL ENGINEER SHALL BE RETAINED TO EVALUATE THE SOIL CONDITIONS. NOTIFY THE ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. • 1,500 PSF (ALLOWABLE BEARING PRESSURE) • 35 PCF+ SURCHARGE (ACTIVE LATERAL PRESSURE) • 200 PCF (PASSIVE PRESSURE) • 0.35 (COEFFICIENT OF FRICTION) FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR COMPACTED STRUCTURAL FILL AS REQUIRED BY THE GEOTECHNICAL ENGINEER. FOOTINGS SHALL BE PLACED AT A MINIMUM OF THE FROST DEPTH REQUIRED BY THE LOCAL JURISDICTION. FOOTING ELEVATIONS SHOWN IN THE DRAWINGS REPRESENT MINIMUM DEPTHS AND ARE FOR BIDDING ONLY. FINAL FOUNDATION ELEVATIONS ARE SUBJECT TO SITE CONDITIONS AND SHALL BE ESTABLISHED BY THE CONTRACTOR. FOOTINGS SHALL BE CENTERED BENEATH THE STRUCTURE ABOVE, UNLESS DIMENSIONED OTHERWISE. THE CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING EXCAVATION, PILE INSTALLATION, AND ANY OTHER CONSTRUCTION EARTHWORK. NOTIFY THE UNDERGROUND UTILITIES LOCATION SERVICE AT LEAST 1 WEEK PRIOR TO CONSTRUCTION AND INDEPENDENTLY VERIFY ALL UTILITIES WHICH MAY BE AFFECTED BY THIS PROJECT. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL DAMAGE DAMAGE TO UNDERGROUND UTILITIES RESULTING FROM THEIR WORK. IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MAXIMUM PARTICLE DIAMETER OF THREE INCHES AND NO MORE THAN 10% FINES (PASSING THE #200 SIEVE). FILL AND BACKFILL MATERIAL SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE INCHES IN LOOSE THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITYAS DETERMINED BYASTM D1557. BACKFILL BEHIND ALL RETAINING WALLS WITH WELL -DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. PROVIDE WATER PROOFING SYSTEM AT EXTERIOR FACE OFALL FOUNDATION WALLS EXPOSED TO EARTH PER ARCHITECTURAL SPECIFICATIONS. CONCRETE ALL CONCRETE WORK SHALL BE PERFORMED IN ACCORDANCE WITH ACI 301 "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE" AND ACI 318, "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE". THE CONCRETE SHALL HAVE A UNIT WEIGHT OF APPROXIMATELY 150 PCF CONCRETE STRENGTHS AT 28 DAYS (fc) AND MIX CRITERIA SHALL BE AS FOLLOWS: • SLAB -ON -GRADE: f'c = 2,500 PSI 0.55 WIC RATIO • FOUNDATION & WALLS: f'c = 2,500 PSI 0.55 WIC RATIO A CONCRETE MIX DESIGN SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL IF REQUIRED IN THE SUBMITTAL SPECIFICATIONS. THE MIX DESIGN SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH ACI REQUIREMENTS. ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR -ENTRAINED IN ACCORDANCE WITH ACI TABLE 4.2.1 FOR MODERATE EXPOSURE CONDITION. REINFORCING STEEL REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615 GRADE 60. REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. WELDED WIRE REINFORCING SHALL CONFORM TO ASTM A185. PROVIDE WELDED WIRE FABRIC IN SHEETS WITH 12" LAPS AT SIDES AND ENDS. REINFORCING STEEL SHALL BE DETAILED TO INCLUDE HOOKS AND BENDS IN ACCORDANCE WITH ACI SP-66 AND ACI 318. DEVELOPMENT LENGTHS AND LAP SPLICES SHALL BE PER THE SCHEDULE. MECHANICAL SPLICING OF REINFORCING BARS, IF REQUIRED, SHALL BE BYAN ICBO APPROVED SYSTEM, AND SHALL DEVELOP 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR. ALL SPLICE DEVICES SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET -SETTING ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS APPROVED BY THE ENGINEER. REFER TO ACI FOR PLACING TOLERANCES AND OTHER REINFORCING STEEL REQUIREMENTS. DEVELOPMENT LENGTH AND LAP SPLICE REINFORCING DEVELOPMENT LENGTHS AND LAP SPLICES SHALL BE AS FOLLOWS. ALL LENGTHS ARE IN INCHES BASED ON GRADE 60 REINFORCING. CONSULT ENGINEER FOR OTHER GRADES OF STEEL. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12" OF CONCRETE CAST BELOW THE BAR. f'c = 2500 PSI f'c = 3000 PSI BAR SIZE DEVELOPMENT LENGTH LAP SPLICE DEVELOPMENT LENGTH LAP SPLICE TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS #3 23 18 30 23 22 17 28 22 #4 31 24 41 31 29 22 37 29 #5 39 30 51 39 36 28 47 36 47 36 61 __F#6 47 43 33 56 43 CONCRETE GENERAL NOTES WALL AND COLUMN VERTICAL BARS SHALL START FROM THE TOP OF FOOTING. HORIZONTAL BARS SHALL START A DISTANCE OF 1/2 THE NORMAL BAR SPACING FROM TOP OF FOOTING AND/OR TOP OF FRAMED SLABS. THERE SHALL BE AN ADDITIONAL HORIZONTAL BAR AT A MAXIMUM OF 3" FROM EVERY TOP OF WALL AND BOTTOM OF FRAMED SLABS. PROVIDE CORNER BARS TO MATCH AND LAP ALL HORIZONTAL REINFORCING ON EACH SIDE OF THE CORNER PER SCHEDULE OR BEND ONE SIDE OF HORIZONTAL AROUND CORNER TO PROVIDE LAP SPLICE PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS ON GRADE TO BREAK UP EACH SLAB INTO RECTANGULAR AREAS OF NOT MORE THAN 400 SQUARE FEET. AREAS SHALL BE AS SQUARE AS PRACTICAL AND HAVE NO ACUTE ANGLES. JOINT LOCATIONS SHALL BE APPROVED BY THE ARCHITECT PRIOR TO PLACEMENT. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED BEYOND JOINT UNLESS NOTED OTHERWISE IN PLAN. SEE ARCHITECTURAL DRAWINGS AND MECHANICAL DRAWINGS FOR EXACT SIZE AND LOCATION OF OPENINGS IN CONCRETE WALLS, FLOORS, AND ROOF. UNLESS INDICATED OTHERWISE, REINFORCE AROUND OPENINGS GREATER THAN 12" IN ANY DIRECTION WITH (1) #5 EACH SIDE AND (1) #5 x 4'-0" DIAGONAL AT EACH CORNER. EXTEND BARS 2'-0" BEYOND EDGE OF OPENING. IF 2'-0" IS UNAVAILABLE, EXTEND AS FAR AS POSSIBLE AND HOOK. HOOK ALL REINFORCING INTERRUPTED BY OPENINGS. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, STRIPS, TEXTURE, AND OTHER FINISH DETAILS AT EXPOSED CONCRETE SURFACES. PROVIDE 3/41, CHAMFER AT ALL CORNERS LINO. STRUCTURAL STEEL ALL STRUCTURAL STEEL WORK SHALL BE PERFORMED IN ACCORDANCE WITH AISC "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" AND AWS D 1.1 "STRUCTURAL WELDING CODE - STEEL ". STEEL SHALL BE FABRICATED AND ERECTED WITHIN THE TOLERANCES DEFINED BY AISC. STRUCTURAL STEEL MATERIALS SHALL BE AS FOLLOWS: • SHAPES SHALL CONFORM TO ASTM A992, Fy = 50 KSI. PLATES ANGLES AND RODS SHALL CONFORM TO ASTM A36 Fy - 36 KSI. • STRUCTURAL TUBING SHALL CONFORM TO ASTM A500 GRADE B, Fy = 46 KSI. • STRUCTURAL PIPE SHALL CONFORM TO ASTM A53 GRADE B, Fy = 35 KSI. • BOLTS SHALL CONFORM TO ASTM A325-N (USE 5/870 MINIMUM UNO) • ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 GRADE 36, Fy = 36 KSI. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS IN ACCORDANCE WITH AWS AND WABO REQUIREMENTS. USE 70 KSI LOW HYDROGEN ELECTRODES APPROPRIATE FOR THE MATERIALS BEING WELDED. IF NOT SPECIFIED, MINIMUM WELD SIZE SHALL BE PER AWS D1.1. WELDING OF REINFORCING BARS SHALL NOT BE PERMITTED UNLESS SPECIFICALLY CALLED OUT ON DRAWINGS. ALL STEEL EXPOSED TO WEATHER SHALL BE FABRICATED IN ACCORDANCE WITH ASTM A385 AND HOT DIP GALVANIZED IN ACCORDANCE WITH ASTM A123. FASTENERS AND HARDWARE SHALL BE HOT DIP GALVANIZED IN ACCORDANCE WITH ASTM A153. ALL DAMAGED GALVANIZED COATINGS SHALL BE REPAIRED IN ACCORDANCE WITH ASTM A780 WITH AN APPLIED COATING THICKNESS DETERMINED BY THE ENGINEER. WOOD FRAMING ALL WOOD FRAMING SHALL BE PERFORMED IN ACCORDANCE WITH IBC CHAPTER 23, ANSI/AWC "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION", AND AITC "TIMBER CONSTRUCTION MANUAL". SAWN LUMBER SHALL BE IDENTIFIED BY THE GRADE MARK OF AN AGENCYAPPROVED BYAN ACCREDITATION BODY COMPLIANT WITH DOC PS 20. ALL GRADES SPECIFIED IN THE STRUCTURAL DRAWINGS ARE MINIMUM STANDARDS AND SHALL BE AS FOLLOWS: • STUDS, PLATES, AND BLOCKING HEM -FIR STUD GRADE MINIMUM CONCRETE COVER ON REINFORCING STEEL SHALL BE AS FOLLOWS: 0 JOISTS DOUG-FIR #2 • 4x OR SMALLER BEAMS AND HEADERS DOUG-FIR #2 • CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH. 3" 0 6x OR LARGER BEAMS AND HEADERS DOUG-FIR #1 • CONCRETE EXPOSED TO EARTH AND WEATHER: • POSTS AND TIMBERS DOUG-FIR #2 #6 BARS AND LARGER 2" #5 BARS AND SMALLER 1 1/2" WOOD FRAMING SHALL BE KILN -DRIED TO A MAXIMUM MOISTURE CONTENT OF 19%. ALL WOOD IN CONCRETE NOT EXPOSED TO • EARTH OR WEATHER: CONTACT WITH CONCRETE OR MASONRY, OR EXPOSED TO EARTH OR WEATHER SHALL BE PRESSURE SLABS, WALLS, AND JOISTS 3/4" TREATED IN ACCORDANCE WITH AWPA STANDARD U1 AND M4 FOR THE SPECIES, PRODUCT, BEAM/COLUMN TIES AND STIRRUPS 1 1/2" PRESERVATIVE, AND END USE REQUIRED. GLUED LAMINATED TIMBER SHALL BE MANUFACTURED AND IDENTIFIED IN CONFORMANCE WITH ANSI/AITC A 190.1 AND ASTM D3737. UNLESS OTHERWISE SPECIFIED, ALL GLUED LAMINATED TIMBERS SHALL BE DOUGLAS FIR SPECIES. SINGLE SPAN BEAMS SHALL BE COMBINATION 24F-V4 AND MULTI -SPAN BEAMS OR BEAMS THAT CANTILEVER SHALL BE COMBINATION 24F-V8. ALL EXPOSED GLULAMS SHALL HAVE AN ADDITIONAL TENSION LAMINATION SUBSTITUTED FOR A CORE LAMINATION ON THE TENSION SIDE OF UNBALANCED 24F-V4 BEAMS AND ON BOTH SIDES OF BALANCED 24F-V8 BEAMS. STRUCTURAL WOOD PANEL SHEATHING USED ON WALLS, FLOORS, OR ROOFS SHALL CONFORM TO THEIR SPECIFIC REQUIREMENTS IN DOC PS 1, DOC PS 2, OR ANSI/APA PRP 210. PLYWOOD SHALL BE GRADE C-D WITH EXTERIOR GLUE. REFER TO IBC SECTIONS 2303.1.4, 2304.6, AND 2304.7 FOR ADDITIONAL COMPLIANCE REQUIREMENTS. PRE -MANUFACTURED JOISTS, BEAMS, AND TRUSSES PRE -MANUFACTURED JOISTS, BEAMS, AND TRUSSES SHALL BE SIZED, SPACED, AND DETAILED TO MATCH THE LOADING AND DIMENSIONAL REQUIREMENTS INDICATED ON THE STRUCTURAL DRAWINGS. TRUSSES SHALL COMPLY WITH IBC 2303.4, I -JOISTS SHALL COMPLY WITH IBC 2303.1.2, AND COMPOSITE BEAMS SHALL COMPLY WITH 2303.1.9. THE MANUFACTURER'S DESIGNER IS RESPONSIBLE FOR CODE COMPLIANCE AND SHALL PROVIDE SHOP DRAWING AND CALCULATION SUBMITTALS AS SPECIFIED. ENGINEER AND BUILDING OFFICIAL APPROVAL IS REQUIRED PRIOR TO FABRICATION OF PRE -MANUFACTURED COMPONENTS. REFER TO THE DESIGN LOADS FOR BASIC STRUCTURAL LOADING REQUIREMENTS. REFER TO THE ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR ADDITIONAL LOADING AND OPENING REQUIREMENTS NOT SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS. DEFLECTIONS SHALL NOT EXCEED L/480 FOR LIVE LOADS OR L/360 FOR TOTAL LOADS UNLESS APPROVED IN WRITING BY THE ENGINEER. ALL TRUSSES WITH A DEPTH EQUAL TO OR GREATER THAN 24" SHALL BE DESIGNED FOR A BOTTOM CHORD LIVE LOAD OF 10PSF, NOT APPLIED CONCURRENT WITH THE TOP CHORD LIVE LOAD. PROVIDE TEMPORARY BRACING UNTIL SHEATHING AND PERMANENT BRACING IS INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. THE MANUFACTURER SHALL PROVIDE ALL SPECIALTY ITEMS REQUIRED FOR A COMPLETE INSTALLATION OF THE SYSTEM (INCLUDING BUT NOT LIMITED TO FULL DEPTH BRIDGING, BLOCKING, WEB STIFFENERS, AND PRODUCT SPECIFIC CONNECTORS. NAILS, SCREWS, BOLTS, AND CONNECTORS REFER TO THE PLANS, NOTES, SCHEDULES, AND DETAILS FOR ALL NAILING REQUIREMENTS. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1. ALL NAILS SHALL CONFORM TO THE STANDARD DIMENSIONS OF COMMON NAILS AS DEFINED BY THE NDS AND SHALL MEET THE FOLLOWING MINIMUM GUIDELINES: • 8d = 0.131 "0 x 2 1/2" • 10d = 0.14870 X 3" • 16d=0.162"0x31/2" 10d BOX NAILS (0.128"0 x 3) MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.14870 x 3 1/4'), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THE DRAWINGS. OTHER NAILS MAY BE SUBSTITUTED ONLY WITH THE ENGINEER'S APPROVAL PRIOR TO START OF CONSTRUCTION. ALL LAG SCREWS AND BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE STANDARD CUT WASHERS UNDER THE HEADS AND NUTS OF ALL LAG SCREWS AND BOLTS BEARING ON WOOD. LEAD HOLES FOR BOLTS SHALL BE PROVIDED AND SHALL BE A MINIMUM OF 1/321, AND A MAXIMUM OF 1/16" LARGER THAN THE BOLT DIAMETER. LEAD HOLES FOR LAG SCREW SHANK AND THREADS SHALL BE PER NDS 12.1.4.2. ALL WOOD CONNECTORS SHALL BE SIMPSON STRONG -TIE OR ENGINEER APPROVED EQUIVALENT. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS USING THEIR SPECIFIED NUMBER AND SIZE OF FASTENERS. IF STRAPS CONNECT TWO MEMBERS, PLACE 1/2 OF THE NAILS, SCREWS, OR BOLTS INTO EACH MEMBER. ALL NAILS, SCREWS, BOLTS, AND METAL CONNECTORS IN CONTACT WITH PRESSURE TREATED OR FIRE RETARDANT TREATED WOOD SHALL BE HOT DIP GALVANIZED IN ACCORDANCE WITH ASTM A153. WOOD FRAMING GENERAL NOTES SILL PLATES BEARING ON CONCRETE FOUNDATIONS SHALL BE PRESSURE TREATED AND SHALL ATTACH TO THE CONCRETE WITH 1/2"0 ANCHOR BOLTS EMBEDDED 7" MINIMUM. PLACE ANCHORS AT 4'-0" OC MAXIMUM FOR SHEAR WALLS AND AT 6'-0" OC FOR BEARING AND PARTITION WALLS. USE A MINIMUM OF (2) ANCHOR BOLTS PER SILL PLATE AND PLACE ONE WITHIN 12" OF EACH END OF EACH PIECE. REFER TO THE SHEAR WALL SCHEDULE FOR MORE STRINGENT ANCHORAGE SIZE AND SPACING REQUIREMENTS. CONTRACTOR SHALL INSTALL 3 GAUGE PLATE WASHERS BENEATH EACH NUT AT EACH ANCHOR BOLT IN A SHEAR WALL THAT EXTEND TO WITHIN 1/2" OF SHEATHED EDGE. ALL SHEAR AND/OR BEARING WALLS SHALL BE FRAMED WITH 2x STUDS @a 16" OC. REFER TO PLAN NOTES FOR TYPICAL HEADER SIZES NOT SPECIFICALLY CALLED OUT. ALL HEADERS SHALL BE SUPPORTED BYA MINIMUM OF (1) CRIPPLE AND (1) FULL HEIGHT STUD. COLUMNS BELOW FLUSH FRAMED MULTIPLE JOIST BEAMS SHALL BE EQUAL IN WIDTH TO THE BEAM. ALL COLUMNS NOT CALLED OUT SHALL BE (2) STUDS. BEAMS SHALL HAVE FULL BEARING ON COLUMNS AND POSITIVE CONNECTION SHALL BE PROVIDED. PROVIDE SOLID BLOCKING BETWEEN JOISTS AND RAFTERS AT ALL SUPPORTS, AT 8'-0" OC MAXIMUM SPACING BETWEEN SUPPORTS, AND BENEATH PARTITIONS PERPENDICULAR TO THE DIRECTION OF FRAMING. INSTALL DOUBLE JOISTS UNDER PARTITIONS EXTENDING ONE HALF OR MORE OF THE JOIST SPAN. MINIMUM NAILING REQUIREMENTS SHALL BE PER IBC TABLE 2304.10.1. THE USE OF NAIL GUNS IS APPROVED IF NAILING INTO THE DIAPHRAGMS IS FLUSH WITH FACE OF SHEATHING. NAIL PENETRATIONS GREATER THAN 1/16" ARE NOT ACCEPTABLE. NOTCHES AND HOLES IN WALL STUDS ARE ALLOWED WITHIN THE PARAMETERS OF IBC SECTIONS 2308.5.9 AND 2308.5.10. NOTCHES AND HOLES IN JOISTS AND RAFTERS ARE ALLOWED WITHIN THE PARAMETERS OF IBC SECTIONS 2308.4.2 AND 2308.7.4. VERTICAL SHRINKAGE WILL OCCUR AND ACCUMULATE AT EACH LEVEL FROM THE WOOD DRYING OVER TIME. THIS IS ESTIMATED TO BE APPROXIMATELY 0.15" PER FLOOR AND ASSUMES THE WOOD HAS AN INITIAL MOISTURE CONTENT OF 19% OR LESS. ADDITIONAL SHRINKAGE WILL OCCUR IF THE MOISTURE CONTENT IS HIGHER. THE CONTRACTOR SHALL ALLOW FOR THIS MOVEMENT IN THEIR INSTALLATION OF ALL VERTICAL ASSEMBLIES INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, MECHANICAL, AND ARCHITECTURAL SYSTEMS. GENERAL NOTES STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THEARCHITECTURAL, CIVIL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. REFER TO THE ARCHITECTURAL DRAWINGS FOR ELEVATIONS, SLOPES, NON -BEARING WALLS, STAIRS, CURBS, DRAINS, RAILINGS, WATERPROOFING, FINISHES, ETC. REFER TO THE ARCHITECTURAL, CIVIL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF PIPES, VENTS, DUCTS, AND OTHER OPENINGS NOT SPECIFICALLY INDICATED ON THE STRUCTURAL DRAWINGS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND FIELD CONDITIONS FOR COMPATIBILITY WITH THE PLANS, SPECIFICATIONS, AND REFERENCED STANDARDS BEFORE PROCEEDING WITH ANY WORK. THE MOST STRINGENT REQUIREMENT SHALL GOVERN ANY CONFLICT UNLESS APPROVED IN WRITING OTHERWISE. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN TEAM BEFORE PROCEEDING. CONTRACTOR SHALL BE RESPONSIBLE FOR STRENGTH AND STABILITY OF ANY PARTLY COMPLETED STRUCTURE. CONTRACTOR IS SOLELY RESPONSIBLE FOR JOB SITE SAFETY AND SHALL PROVIDE TEMPORARY SHORING AND SUPPORT AS REQUIRED UNTIL THE STRUCTURE HAS BEEN COMPLETED. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE DESIGN TEAM FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES ON SHOP DRAWINGS DO NOT SATISFY THIS REQUIREMENT. REVIEW OF ALTERNATE SYSTEMS MAY BE AN ADDITIONAL SERVICE BY THE ENGINEER. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE DESIGN TEAM. APPROVED PLANS MUST BE ON JOB SITE LEGEND DEFINITION SYMBOL DEFINITION SYMBOL DIRECTION OF NATIVE SOIL III=III=III=III= FRAMING EXTENT OF lift GRANULAR FILL FRAMING COLUMNS STRUCTURAL STEEL COLUMN BEARING ON BEAM P RATED SHEATHING G� BEAM CONTINUOUS SHEAR WALL SWX OVER SUPPORT (SEE SCHEDULE) COLUMN MARK G� CONCRETE WALL (SEE SCHEDULE) / BEARING STUD FOOTING MARK O WALL (SEE SCHEDULE) NON -BEARING HOLDOWN MARK STUD WALL (SEE SCHEDULE) BEARING STUD HANGER MARK X O SHEAR WALL (SEE SCHEDULE) NON -BEARING FLAG NOTE STUD SHEAR WALL (SEE PLAN NOTES) CMU WALL STEEL MOMENT FRAME CONN. ABBREVIATIONS (A) AB ALT ABOVE ANCHOR BOLT ALTERNATE GLB GLUE -LAMINATED BEAM HORIZ HORIZONTAL KP KING POST ARCH ARCHITECT KSI KIPS PER SQUARE INCH (B) BELOW L ANGLE BD BAR DIAMETER MECH MECHANICAL BLKG BLOCKING MF MOMENT FRAME BM BEAM MTL METAL NS NEAR SIDE OC ON CENTER BOT BOTTOM BRNG BEARING BTWN BETWEEN OPP OPPOSITE CJP COMPLETE JOINT PENETRATION PL PLATE CLR CLEAR PLCS PLACES CMU CONCRETE MASONRY UNIT PSI POUNDS PER SQUARE INCH COL COLUMN PSF POUNDS PER SQUARE FOOT P/T POST TENSIONED PT PRESSURE TREATED CONC CONCRETE CONN CONNECTION CONT CONTINUOUS REINF REINFORCING COORD COORDINATE REQ'D REQUIRED DBL DOUBLE SCHED SCHEDULE DET DETAIL DIAMETER DIMENSION DIRECTION SIM SIMILAR DIA SOG SLAB ON GRADE STD STANDARD STIFF STIFFENER DIM DIR EA EACH STL STEEL ELEV ELEVATION SYMM SYMMETRICAL ES EACH SIDE SW SHEARWALL EX EXISTING EXP EXPANSION FLR FLOOR TOC TOP OF CONCRETE TOS TOW TOP OF STEEL TOP OF WALL FDN FOUNDATION TYP TYPICAL FTG FOOTING UNO UNLESS NOTED OTHERWISE FS FAR SIDE GC GENERAL CONTRACTOR VERT VERTICAL WF WIDE FLANGE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE The following documentation shall be available on site for the building inspector: ■ NE] COE APPROVED ARCHITECTURAL PLAN SET ] COE APPROVED STRUCTURAL PLAN SET [:]COE REVIEWED CALCULATION PACKET ' ❑ ENERGY CREDIT WORKSHEET ■ ❑ SITE PLAN ; ❑ CIVIL PLAN ■❑ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ■ a� A V W 0 LU c ^ N � Z 0 Q ( W OBLD2023- O V RECEI' Nov 22 I� (J Uj CITY OF EDM DEVELOPMENTS DEPARTME O CL O A� pF WASk Tsai s SIGNAL 01l 26/ 23 REV. DATE DESCRIPTION 0 07126123 PERMIT SUBMITTAL PROJECT NO.: 23043.01 DESIGNED BY: LFM DRAWN BY: LFM CHECKED BY: CAB SHEET TITLE: STRUCTURAL NOTES SHEET NO.: 1461 VED 023 )NDS RVICES NT FOUNDATION PLAN NOTES: NO FOUNDATION MODIFICATIONS WITHIN THE BASEMENT. HOLDOWN SCHEDULE CHORD ANCHOR CAPACITY MARK TYPE SIZE STUD NAILS OR BOLTS BOLT (LB) (NOTE 3) (NOTE 2) 1 DTT2Z (1) 2x (8) 1/4"x 1 1/2" SDS 1/2'0 1800# NOTES. 1. REFER TO THE LATEST SIMPSON STRONG -TIE CATALOG FOR ADDITIONAL INSTALLATION REQUIREMENTS. 2. ANCHOR BOLTS SHALL EXTEND INTO FOOTING OR FOUNDATION WALL PER DETAIL 6/S3.1. USE PABX-12 ANCHORS AT INTERIOR FOOTINGS AND PABX-30 ANCHORS EXTENDING THRU THE STEM AT EXTERIOR FOOTINGS. INCREASE FOOTING DEPTHS AS REQUIRED FOR ANCHORAGE. 3. AT ALL HOLDOWN CHORDS, PROVIDE PANEL EDGE NAILING PER SHEAR WALL SCHED. SHEAR WALL SCHEDULE RIM JOIST SILL PLATE SILL PLATE FOUNDATI MIN FRAMING NAILING SHEAR APA-RATED OR BLOCK NAILING TO ANCHOR BOLT TO ON SILL TYPE AT ADJOINING AT PANEL CAPACITY SHEATHING CONN TO RIM/BLKG SLAB OR PLATE PANEL EDGES EDGES (PLF) TOP PLATE BELOW FOUNDATION SIZE SW6 15/32" 2x STUD 0.131 '0 x 2 1/2" LTP4 OR A35 0.131 "0 x 3 1/4" 5/8"0 AB @a 5'-8" OC OR 2x 242 ONE SIDE AND BLKG @ 6" OC �a 26" OC 6.5" OC 1/2"0 AB 1? 3'-10" OC NOTES. 1. REFER TO THE SHEAR WALL DETAIL IN THE TYPICAL WOOD FRAMING DETAILS. 2. THE VALUES IN THIS TABLE ARE BASED ON HF GRADE STUDS AND HF GRADE PLATES & RIM/BLOCKING. 3. NAILS AT ADJOINING PANEL EDGES SHALL BE STAGGERED EACH SIDE OF THE COMMON JOINT. 4. INTERMEDIATE FRAMING TO BE WITH 2x MINIMUM MEMBERS. FIELD NAILING 12" OC MAXIMUM. 5. AT ALL SILL PLATE ANCHOR BOLTS IN 2x6 WALLS, INSTALL 3 GA x 3" x 4 1/2" PLATE WASHERS WITH THE EDGE OF PLATE WASHER WITHIN 1/2" OF SHEATHED EDGE. FOR 2x4 STUD WALLS, INSTALL 3 GA. x 3" x 3" PLATE WASHERS. 6. PROVIDE A MINIMUM OF 7" EMBEDMENT FOR AB INTO FOUNDATION OR STEM WALL. 7. 7/16" SHEATHING MAY BE USED IN PLACE OF 15/32" SHEATHING PROVIDED ALL STUDS ARE SPACED 16" OC OR PANELS ARE APPLIED WITH LONG DIMENSION ACROSS STUDS. FOUNDATION PLAN SCALE: 3/16" = 1 '-0" EXISTING BASEMENT WALL CD Z c' W W Z W o --%w00% c �• I.. j V W 0 ca Lu 0 N Z � Q O Q W OBLD2023- O RECE[ Nov 22 I� U Lli CITY OF EDM DEVELOPMENT: DEPARTME O O AWA � 40785 �sIONAL 07l26123 REV. DATE DESCRIPTION 0 07126123 PERMIT SUBMITTAL PROJECT NO.: 23043.01 DESIGNED BY: LFM DRAWN BY: LFM CHECKED BY: CAB SHEET TITLE: FOUNDATION PLAN 1461 VED '023 DNDS -ERVICES NT SHEET NO.: S2.1 FOUNDATION PLAN NOTES: 1. PLACE ALL REINFORCING STEEL, ANCHOR BOLTS, AND HOLDOWNS PER THE STRUCTURAL NOTES AND SCHEDULES ON THE S1 SHEETS AND THE FOUNDATION DETAILS ON THE S3 SHEETS. REFER TO THE FRAMING PLANS FOR LOCATION OF SHEAR WALLS. 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, WALL LOCATIONS, UTILITY PLACEMENT, AND CONCRETE ROUGH OPENINGS WITH THE ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION AND NOTIFY ALL PARTIES OF ANY DISCREPANCIES. 3. EXTERIOR FOOTINGS SHALL BEAR ON FIRM NATIVE SOIL OR COMPACTED STRUCTURAL FILL A MINIMUM OF 1'-6" BELOW GRADE. REFER TO THE STRUCTURAL NOTES FOR ADDITIONAL SUBGRADE PREPARATION REQUIREMENTS AND FOR CONDITIONS REQUIRING STRUCTURAL FILL. 4. TYPICAL SLAB ON GRADE SHALL BE A MINIMUM OF 4" THICK w/ 6x6 - W1.4xW1.4 WELDED WIRE FABRIC REINFORCING. PROVIDE 2" MINIMUM CLEARANCE FROM WWF TO BOTTOM OF SLAB. CRAWL SPACE RAT SLAB MAYBE REDUCED TO 2" THICKNESS. REFER TO ARCHITECTURAL DRAWINGS. SLABS SHALL BE PLACED OVER A 10 MIL VAPOR BARRIER ATOP RIGID INSULATION PER ARCH OVER 4" OF SUITABLE DRAINING SUBGRADE MATERIAL. 5. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING FINAL FOOTING ELEVATIONS BASED ON FIELD CONDITIONS & FOR COORDINATING TOW & TOF ELEV W/ARCH DRAWINGS. 6. CONTROL JOINTS ARE REQUIRED IN THE SLAB ON GRADE. REFER TO THE TYPICAL SLAB ON GRADE DETAILS FOR CONSTRUCTION REQUIREMENTS. ALL JOINT LOCATIONS SHALL BE APPROVED BY THE ENGINEER AND ARCHITECT PRIOR TO PLACING CONCRETE. (3) 2x 10, TYF 7. ALL CONTINUOUS FOOTING REINFORCING SHALL BE PLACED THRU SPREAD FOOTINGS IF APPLICABLE. PROVIDE CORNER, HOOKED, OR BENT BARS MATCHING FOOTING REINFORCING AT ALL INTERSECTIONS AND CHANGES IN FOOTING DIRECTION. 8. REFER TO ARCHITECTURAL DRAWINGS FOR VENT LOCATIONS. FLOOR FRAMING PLAN NOTES. 1. REFER TO THE STRUCTURAL NOTES AND SCHEDULES ON THE S1 SHEETS AND TO THE TYPICAL WOOD FRAMING DETAILS ON THE S4 SHEETS FOR FRAMING REQUIREMENTS NOT SPECIFICALLY SHOWN ON THE FLOOR FRAMING PLAN OR IN THESE PLAN NOTES. 2. FLOOR SHEATHING SHALL BE 314" MINIMUM THICKNESS WITH A 40120 SPAN RATING. ATTACH TO FRAMING BELOW WITH 10d NAILS SPACED AT 6" OC AT ALL DIAPHRAGM BOUNDARIES, PANEL EDGES, SHEAR WALLS, AND COLLECTOR ELEMENTS INDICATED ON PLANS. NAILING AT INTERMEDIATE FRAMING SHALL BE 10d NAILS SPACED AT 12" OC. REFER TO TYPICAL FRAMING DETAILS FOR SHEATHING LAYOUT. PROVIDE ADHESIVE ATOP EACH JOIST AS SPECIFIED BY THE ARCHITECT BEFORE INSTALLING SHEATHING. FLOOR SHEATHING IS UNBLOCKED UNO ON PLAN 3. WALL STUD FRAMING SHALL BE AS FOLLOWS: 2x6 HF STUD Ca 16" OC FOR EXTERIOR WALLS AND INTERIOR 6" BEARING WALLS. 2x4 HF STUD Ca 16" OC FOR INTERIOR 4" BEARING WALLS. 2x4 OR 2x6 HF STUDS Ca 16" OC FOR INTERIOR NON -BEARING WALLS REFER TO ARCHITECTURAL DRAWING FOR DETERMINATION OF WALL TYPE. ALL SILL AND TOP PLATES SHALL BE HF STUD GRADE. 4. ALL COLUMNS, TRIMMER STUDS, AND BEARING WALLS SHALL BE CONTINUED DOWN TO THE FOUNDATION UNLESS SUPPORTED BYA BEAM BELOW. SOLID BLOCKING SHALL BE PROVIDED WITHIN JOIST SPACES AT THESE LOCATIONS. PROVIDE (2) STUDS MINIMUM AT FLUSH BEAMS UNO. 5. MULTIPLE PLY BEAMS SHALL BE FASTENED TOGETHER WITH (2) ROWS OF 10d @a 12" OC. PROVIDE 2" MINIMUM EDGE DISTANCE TOP & BOTTOM AND ALTERNATE NAILING ON EACH FACE OF BEAM. 6. PROVIDE CS16 STRAP AT LOCATIONS WHERE COLUMN OR BEAM CUTS DOUBLE TOP PLATE. EXTEND STRAP 12" BEYOND THE CUT EACH DIRECTION WITH (10) 10d EA SIDE. 7. REFER TO DESIGN LOADS ON S-1 FOR ADDITIONAL LOAD AND SUBMITTAL REQUIREMENTS. CONTRACTOR SHALL PROVIDE ALL TEMPORARY & SAFETY BRACING & BLOCKING AS REQ'D BY THE MANUFACTURER. 8. CONVENTIONALLY FRAME STAIRS PER TYPICAL DETAILS OR PER ARCH. FLOOR FRAMING PLAN SCALE: 3/16" = 1 '-0" CD Z c' W W Z W o --%w00% c �• I.. j a� C a V W 0 Lu 0 N Z Q � W OBLD2023- O RECEI' Nov 22 I� U Lli CITY OF EDM DEVELOPMENT: DEPARTME a O AWA � 40785 �sIONAL 07l26123 REV. DATE DESCRIPTION 0 07126123 PERMIT SUBMITTAL PROJECT NO.: 23043.01 DESIGNED BY: LFM DRAWN BY: LFM CHECKED BY: CAB SHEET TITLE: FLOOR FRAMING PLAN 1461 VED '023 DNDS -ERVICES NT SHEET NO.: S2.2 ROOF FRAMING PLAN NOTES: 1. REFER TO THE STRUCTURAL NOTES AND SCHEDULES ON THE S1 SHEETS AND TO THE TYPICAL WOOD FRAMING DETAILS ON THE S4 SHEETS FOR FRAMING REQUIREMENTS NOT SPECIFICALLY SHOWN ON THE ROOF FRAMING PLAN OR IN THESE PLAN NOTES. 2. PLYWOOD ROOF SHEATHING SHALL BE 112" MINIMUM WITH A 32116 SPAN RATING. ATTACH TO FRAMING BELOW WITH 8d NAILS SPACED AT 6" OC AT ALL DIAPHRAGM BOUNDARIES, PANEL EDGES, SHEAR WALLS, AND COLLECTOR ELEMENTS INDICATED ON PLANS. NAILING AT INTERMEDIATE FRAMING SHALL BE SAME SIZE NAILS SPACED AT 12" OC. REFER TO TYPICAL FRAMING DETAILS FOR SHEATHING LAYOUT. ROOF SHEATHING IS UNBLOCKED LINO ON PLAN. 3. TYPICAL HEADERS FOR EXTERIOR AND BEARING WALL LOCATIONS SHALL BE 4x6 DF#2 FOR SPANS LESS THAN 4' SUPPORTED BYA MINIMUM OF (1) JACK STUD AND (1) 2x KING STUD. FOR SPANS UP TO 6, USE 4x10 DF#2 SUPPORTED BY (2) JACK STUDS AND (1) KING STUD. ALL JACK AND KING STUDS SHALL MATCH WIDTH OF WALL FRAMING. 4. WALL STUD FRAMING SHALL BE AS FOLLOWS: • 2x6 HF STUD C 16" OC FOR EXTERIOR WALLS AND INTERIOR 6" BEARING WALLS. • 2x4 HF STUD 0 16" OC FOR INTERIOR 4" BEARING WALLS. • 2x4 OR 2x6 HF STUDS 0 16" OC FOR INTERIOR NON -BEARING WALLS REFER TO ARCHITECTURAL DRAWINGS FOR DETERMINATION OF WALL TYPE. ALL SILL AND TOP PLATES SHALL BE HF STUD GRADE. 5. ALL COLUMNS, TRIMMER STUDS, AND BEARING WALLS SHALL BE CONTINUED DOWN TO THE FOUNDATION UNLESS SUPPORTED BYA BEAM BELOW. SOLID BLOCKING SHALL BE PROVIDED WITHIN JOIST SPACES AT THESE LOCATIONS. PROVIDE (2) STUDS MINIMUM AT FLUSH BEAMS UNO. 6. MULTIPLE PLY BEAMS SHALL BE FASTENED TOGETHER WITH (2) ROWS OF 10d 0 12" OC. PROVIDE 2" MINIMUM EDGE DISTANCE TOP & BOTTOM AND ALTERNATE NAILING ON EACH FACE OF BEAM. 7. PROVIDE CS16 STRAP AT LOCATIONS WHERE COLUMN OR BEAM CUTS DOUBLE TOP PLATE. EXTEND STRAP 12" BEYOND THE CUT EACH DIRECTION WITH (10) 10d EA SIDE. 8. ROOF TRUSSES SHALL BE PRE-ENGINEERED BY OTHERS AND SPACED AT 24" OC UNO. REFER TO DESIGN LOADS ON S1 FOR ADDITIONAL LOAD AND SUBMITTAL REQUIREMENTS. CONTRACTOR SHALL PROVIDE ALL TEMPORARY & SAFETY BRACING & BLOCKING AS REQ'D BY THE MANUFACTURER. 9. ATTACH EACH END OF EVERY OTHER ROOF TRUSS TO THE EXTERIOR WALL TOP PLATE BELOW WITH A SIMPSON H1 CLIP OR SD WC15600 TRUSS SCREW. i ROOF FRAMING PLAN SCALE: 3/16" = 1 '-0" OPENING W/ 2x6 DF#2 AND LUS24 EA END 'S IMED, TYP EXIST COLUMN 4x 12 DF#2 HEADER PE) NOTES, TYP PLAN NOTE, TYP CD Z c' W W Z W o --%w00% c �• I.. j C a V W 0 Lu 0 N � Z Q O � W OBLD2023- O RECEI' Nov 22 I� U Lli CITY OF EDM DEVELOPMENT: DEPARTME a O AWA � 40785 �sIONAL 07l26123 REV. DATE DESCRIPTION 0 07126123 PERMIT SUBMITTAL PROJECT NO.: 23043.01 DESIGNED BY: LFM DRAWN BY: LFM CHECKED BY: CAB SHEET TITLE: ROOF FRAMING PLAN 1461 VED '023 DNDS -ERVICES NT SHEET NO.: S2.3 CORNER BARS WITH LAP EA. LAP SPLICE-41 SIDE MAYBE SUBSTITUTED FOR 900 HOOKED BARS STD 900 HOOK TYP UNO ALTERNATE HOOK FOR SINGLE LAYER ADD VERT AT WALL END FOR SINGLE LAYER • STD 180-HOOK AT WALL ENDS ADD (2) VERT AT WALL END FOR (2) LAYERS • ADDED VERT CORNER, END, AND WALL INTERSECTION BARS SHALL MATCH SIZE OF WALL REINFORCING NOTE: REFER TO STRUCTURAL NOTES, PLANS, AND DETAILS FOR REINF. ALL BARS SHALL BE CONTINUOUS OR SPLICED PER STRUCT NOTES W U J cl- CL Q W U CL CL Q CORNER BARS TO MATCH SIZE AND SPACING OF HORIZ WALL REINF U • CIO _ Q PLACE VERT REINF OUTSIDE UNO LAP SPLICE TYPICAL CONCRETE WALL REINFORCING DETAIL SCALE: NTS ADD (1) #5 IN WALL. EXTEND 2'-0" X-0" MIN BEYOND EA SIDE OF EA STEP =11 III=III- j3" CLR TYP D D12 Ilk LAP SPLICE TYP O III=III= � M ~ _ BENT Z BARS TO MATCH =III & LAP FOOTING REINF UNDISTURBED EARTH OR COMPACTED FILL PER STRUCTURAL NOTES TYPICAL FOOTING STEP SCALE: 112" = 1 '-O" STUD FRAMING PER PLAN OR " NOTES. SHEATHING & NAILING, PER SW SCHEDULE PANEL EDGE NAILING PER SW SCHED TYP Ca ALL SILL PLATES CONT 2x RIM BOARD TO MATCH DEPTH & GRADE OF JOIST FRAMING I PT SILL PL W/ANCHOR BOLT SIZE AND SPACING PER STRUCTURAL I NOTES, PLANS, OR SW SCHED • FINISHED GRADE SLOPED AWAY FROM BLDG PER ARCHCIO T i • IN AREAS WITH EXPOSED CONC FLOORS, EDGE SLAB WITH 118" MAX RADIUS AND FILL JOINT WITH SEALANT 518"0 x 2'-O" SMOOTH SLIP DOWEL BARS AT 12" OC, TYP UNO. GREASE 112 OF BAR X X a CONC SLAB ON GRADE PER PLAN OR NOTES REINF SHALL NOT PASS THRU JOINT CONSTRUCTION JOINT SAWCUT JOINT. IN AREAS WITH CONC SLAB ON GRADE EXPOSED CONC FLOORS FILL JOINT PER PLAN OR NOTES WITH SEALANT. IN LIEU OF SAWCUT JOINTS CONTRACTOR MAY USE PREMOLDED JOINT STRIP. X X X X X X NOTE: 1. CONTROL OR CONSTRUCTION JOINTS ARE REQUIRED TO BREAK UP EACH SLAB INTO RECTANGULAR AREAS OF LESS THAN 400 SQUARE FEET. AREAS SHALL BE AS SQUARE AS PRACTICAL WITH NO ACUTE ANGLES. ALL JOINTS SHALL BE APPROVED BY THE ARCHITECT PRIOR TO PLACEMENT. 2. PLACE SLAB ON GRADE ON VAPOR BARRIER OVER SUITABLE COMPACTED SUBGRADE MATERIAL. REFER TO PLAN NOTES. 3. REFER TO ARCHITECTURAL DRAWINGS OR FOUNDATION PLAN FOR LOCATION OF JOINTS IF BAR REINF USED, PROVIDE CONC SLAB ON GRADE Z' BARS W/ LAP SPLICE PER PER PLAN OR NOTES STRUCTURAL NOTES SLAB STEP PER PLAN- X X . X a f -a xz, X—X 1 CONTROL/CONTRACTION JOINT SLAB STEP DTYPICAL SLAB ON GRADE DETAILS 2 SCALE: 1"= 1'-0" WALL FRAMING, SHEATHING, PROVIDE BLOCK OUT AT SILL PLATE, AND ANCHOR DOOR OPENINGS WHERE BOLTS PER STRUCTURAL REQD. NOTES, PLANS, AND 4"0 PERFORATED PVC PIPE WITH SCHEDULES SLAB ON GRADE AND PERFORATIONS DOWNWARD SUBGRADE PER AND 6" OF 1 " MINUS GRAVEL ALL FOUNDATION PLAN AROUND. WRAP IN NON -WOVEN FINISHED GRADE GEOTEXTILE FABRIC. SLOPE TO SLOPED AWAY FROM 7—J DRAIN 118" PER 1 '-O" MIN. OR PER BLDG PER ARCH k I CIVIL DRAWINGS AS APPLICABLE. I • I — X X X cfl w I OO Oc 000 O Oc O° O� O° oco O ° ° ° o o°� o°°� O°ro O°o O ao O z o op • I —III —III —_III —I 11= °� 00 op c° O O °O0°O °°O O 00 00 o O O ° o0 o #4 (a 16" OC HORIZ W/ (2) 0 O o OO o o W� o OO O 0 OO o CONT AT TOW 00 ° ° O O ° 0 J O° O o 0 ° ° #4 Ca 18" OC VERT AT C �000 0 0 ov o0 °OO 0 ° 00 0 °0 / IIIIII—III_ J 0 LINE OF MAX EXCAVATION.cr /� 1 IF SOIL IS OVER 1 FOOTING DRAIN / 6" "' U EXCAVATED, REPLACE / WITH LEAN MIX CONCRETE. PER TYP DETAIL MIN FIRM BEARING SOIL SIZE & REINF ALT HOOKAS OR COMPACTED PER PLAN & SCHED SHOWN STRUCTURAL FILL TYPICAL FOOTING DRAIN TYPICAL STEM WALL DETAIL SILL PLATE NAILING PER SW SCHED FULL DEPTH BLKG AT ALL COLUMNS & HOLDOWN CHORDS 2x JOIST PER PLAN WITH (3) 8d TOE NAILS TO SILL PL TYP. FLOOR SHEATHING & NAILING PER PLAN NOTES Z� OW SIMPSON A35 EVERY Q Q OTHER JOISTLL uj ¢ U O o Lu cc_ FTG DRAIN PER `= TYPICAL DETAIL W/ (2) CONT AT TOW cc m cc Z �_ OO °° O O O° #4 CC 18" OC VERT W 00 0 O � °O 00 • o °Ooo o ,c ° O o0 °0 Q • III- I_ Q CL _ cr / 6„ z cc M U / / SIZE AND REINF ol ALT HOOKAS PER PLAN SHOWN BEARING FOUNDATION AT CRAWLSPACE O SCALE: 1 " = 1 '-O" SCALE: 1 " = P-O" CONT 2x RIM BOARD TO MATCH DEPTH & GRADE OF JOIST FRAMING SCALE: 1 " = P-O" 1Od Ca 4" OC EA BLOCK (3) 1Od END NAILS EA END EA BLOCK 2x BLKG C& 4'-O" TO z Q •� • MATCH DEPTH & GRADE OF JOIST FRAMING co N • SIMPSON A35 EACH i I BLOCK NOTE: REFER TO BEARING O Op°° 0 O FOUNDATION AT CRAWLSPACE DETAIL FOR INFORMATION NOT o 0000 0 0 • SPECIFICALLY CALLED OUT. 00 p E)o0o0O o o OODDpoOOO • --,•- Ili,�l O 0 oO 0 0 NON -BEARING FOUNDATION AT CRAWLSPACE SCALE: 1"= 1'-O" #4 CONT NOSING BAR FINISHED GRADE OR PAVING SLOPED AWAY FROM BLDG PER ARCH TRENCH EXCAVATION PARALLEL TO FTG SLEEVES TO V-6"ol CLEAR PIPE I" W U NO PIPES MIN ALL SIDES Lu ALLOWED IN j� U) Lu THIS REGION. LOWER FTGS AS REQD TOF PIPE BOF 2/ /' II I I I I 1p LOWER BOF AS REQD PIPE TRENCH EXCAVATION PARALLEL 6" MIN TO FOOTING IS NOT ALLOWED TYP BELOW THIS LINE. STEP FTG AS REQUIRED FOR THIS CONDITION l� PI CA o FULL HT OF HOLDOWN STUDS P N A T FO UNDA TION/WALL S WHERE CONCRE WA WI1�FA HT > 3'-0" EXISTS, MAY EXTEND 24"MIN INTO WALL W/ SHEAR WALL PER PLAN AND SCHED DBL NUT & WASHER AS SHOWN. SSTB ANCHOR BOLTS MAYBE SUBSTITUTED AS ALLOWED IN THE HOLDOWN SCHEDULE. COUNTERSINK ADDITIONAL END STUD WHERE REQD THREADED ROD AS REQD FOR HOLDOWN W/ DBL NUT AND WASHER AT BASE. EXTEND ROD TO BOT OF FTG, UNO ON HOLDOWN SCHED TOP OF FTG HOLDOWN PER PLAN AND SCHED ADD (2) #4 x 4' AT TOP OF INTERIOR FOOTINGS AT HOLDOWN LOCATIONS WITHOUT A STEM WALL. REMAINING FTG REINFORCING NOT SHOWN FOR CLARITY. HOLDOWN DETAIL SCALE: NTS #4 0 18" O.C. EXTEND BAR 12" INTO SLAB O° °� o� obo o� SLAB ON GRADE AND SUBGRADE PER FOUNDATION PLAN. SLOPE SLAB PER ARCH PLAN III=III • X_ X_ X X— X LAN _ o o 1 '-O" MIN BELOW SLAB. 0 -I I I I I oQo°° oQo°o 0 EXTEND TO FTG WHERE — — — — REQD BY PLAN NOTE OR I I I I„III„III„III„III; TO FROST DEPTH WHERE REQD BYJURISDICTION _ I i (2) #4 CONT UNO ON PLANS FOOTING (WHERE APPLICABLE) I I 1 '-0"MIN UNLESS ON ---------------------- FTG, THEN O'-8" MIN. THICKENED SLAB EDGE SCALE: 1"= 1'-O" SCALE: 1"= 1'-O" " 1*4 1 LLJ A 3 3 Lij V Lu Quj p L Q N Z c) (NO Q Q (b W OBLD2023- O RECEI' Nov 22 I� () Lu CITY OF EDM DEVELOPMENTE DEPARTME O cc a O A. pF 1PAS$ OSS` L 5'�y� ONAL 01l26123 REV. DATE DESCRIPTION 0 07126123 PERMIT SUBMITTAL PROJECT NO.: 23043.01 DESIGNED BY: LFM DRAWN BY. LFM CHECKED BY CAB SHEET TITLE: FOUNDATION DETAILS SHEET NO.: S3.1 1461 VED 023 )NDS RVICES NIT HEADER WITH CRIPPLE STUDS PER PLAN (WHERE APPLICABLE) FULL -HEIGHT HOLDOWN CHORD PER SCHEDULE. PROVIDE PANEL EDGE NAILING. PT SILL PLATE W/ANCHOR BOLTS PER SHEAR WALL SCHEDULE. PROVIDE SIMPSON BP PL WASHERS WITHIN 1/2" OF SHEATHING. PROVIDE PANEL EDGE NAILING INTO SILL PL. CONCRETE STEM OR FTG NOTES: 1. REFER TO STRUCTURAL NOTES FOR ADDITIONAL INFORMATION. --------n---- ------n-------n-------n-------ri----- I.I I•I I'I I'I I'I I I II II II II II II II II II II II II II II II II II STAGGER NAILS ON EA I I I I I I I I SIDE OF PANEL JOINT I I I I I I I I I WHERE REQUIRED ON I'I I'I I'I I•I I SHEAR WALL SCHED I I I I I I I I I I FRAMING AT ADJOINING I I I I I I I I I PANEL EDGES PER I I • I I• I I I• I' I SHEAR WALL SCHED i• I / •} I I II II j•{ II II II II jl II I.I I I j• •I I.I I.I I•I I•I I•I II II I I II II II II I I I I •I I I .J L------ I I I I II II j •I II � II II I. I I I, I I.I I I I•I I•I II II I I II I'I II II II II I.I II II II II II II I• I II II II II II II I I II II II II II II I.I II II II II I. I.I I, I I.I I I I•I I•I II II I I II I'I II II II II I.I II II II II II II I• I II II II II II II I I II II II II II I.I II II II II I.I I, I I.I I I I•I I•I II I I II I'I II II II I.I II II II II € II I• I II II II II II I I II II II II € II I.I II II II II I.I I, I I.I I I I•I I•I € I II I'I II II II I II II II _1L------LL------- L ql AB SIZE AND SPACING PER PLAN AND SHEAR WALL SCHEDULE, TYP TYPICAL SHEAR WALL DETAIL SCALE:3/4"= 1'-0" BEAM PE AND SC/­ SIMPSON L A35 EACH COL PER PL SCI, LV II BEAM WIDTH, UNO PARALLEL TO STUD WALL JOIST FRAMING PLAN & SCHEDI STUD WALL FRAMING PER PLAN & NOTES COL P TYPICAL FLUSH BEAM SUPPORT DETAILS SCALE: 1"= 1'-0" II II I II II II II II II II II II 1L--4- _1L------- II II I( RIM BOARD OR BLOCKING BEAM WIDTH, UNO PERPENDICULAR TO STUD WALL III III III III III III II I I' I III III I� PANEL EDGE NAILING PER SHEAR WALL SCHEDULE. PROVIDE EDGE NAILING Caj HOLDOWN CHORDS SHEATHING PER SHEAR WALL SCHEDULE W/ FIELD NAILING Caj 12" OC HOLDOWN CHORD PER SCHEDULE. REFER TO TYPICAL BUILT-UP COLUMN DETAIL ADDITIONAL END STUD IF REQUIRED TO PROVIDE COUNTERSINK FOR HOLDOWN BOLTS HOLDOWN ANCHOR PER SCHEDULE SIMPSON CNW COUPLER NUT W/ SIZE TO MATCH HOLDOWN ANCHORAGE PROVIDE SOLID BLKG EQUAL TO WIDTH OF HOLDOWN CHORD ABOVE CONIC STEM WALL & FTG LENGTH OF NOTCH SHALL NOT EXCEED 1/3RD THE O JOIST DEPTH O T PRE -DRILL HOLE AT CORNERS OF NOTCHES. DO NOT OVERCUT NOTCH AT END OF JOISTS SHALL NOT EXCEED 1/4 THE JOIST DEPTH. DO NOT NOTCH WHERE PRACTICABLE. MAX HOLE 0 SHALL NOT EXCEED 40 % THE STUD DEPTH (I.E. 2 1/4" FOR 2x6, 1 1/4" FOR 2x4). MINIMIZE HOLE DIAMETER WHERE POSSIBLE. x W 0 x NOTCH DEP OR HOLE O 1/4 OF STUD WIDTH MAX z N T 5/8" MIN CLR I-O EDGE NOTES: 1. PANELS SHALL BE 4' x 8' EXCEPT AT BOUNDARIES AND CHANGES IN FRAMING WHERE THE MINIMUM PANEL DIMENSION SHALL BE 24". 2. NAILING SHALL BE PER PLAN AND NOTES. MINIMUM NAIL SPACING IS 6" O.C. AT PANEL EDGES AND 12" O. C. AT INTERMEDIATE FRAMING, UNO. FRAMING AND SPACING PER PLAN (SHEATHING NOT SHOWN FOR CLARITYAT FRAMING) CONT. PANEL EDGES. PROVIDE 2x OR 3x BLKG TIGHT TO FRAMING WHEN SPECIFIED. 4' x 8' SHEATHING PANEL, TYP. STAGGER PANELS 4' PERP. TO FRAMING TYPICAL FLOOR/ ROOF SHEATHING DETAIL SCALE:NTS 0.131"0x3"NAILS Cd) 12" OC 2 1/4" END STAGGERED FACE NAILING TYPICAL DISTANCE, TYP FULL LENGTH OF DBL TOP PLATE TOP CHORD 3" OC SPLICE SPACING BOTTOM (2) ROWS OF (6) 0.131 "O x 3"NAILS CHORD Cd 3" OC EA SIDE OF SPLICE SPLICE PROVIDE CONT TOP PLATES WHERE LENGTH IS 12' OR LESS 6'-0" MIN BETWEEN SPLICES. SPLICES OCCUR AT � OF VERT STUDS TYPICAL TOP PLATE SPLICE DETAIL SCALEI"= 1'-0" MAX HOLE O SHALL NOT EXCEED 1/3 THE JOIST DEPTH (I.E. 3" FOR 2x10, 3.75" FOR 2x 12). MINIMIZE HOLE DIAMETER WHERE POSSIBLE. ccO J m U �s ?O N 2x JOISTS PER PLAN OR SCHEDULE. REFER TO MFR RECOMMENDATIONS FOR I -JOIST HOLES AND NOTCHES. NOTE: 1. NOTCHES ARE NOT PERMITTED IN THE MIDDLE 1/3 OF THE JOIST SPAN. 2. NOTCHES ARE NOT PERMITTED ON THE BOTTOM (TENSION FACE) OF JOISTS WHERE THE WIDTH IS 4x OR GREATER. ALLOWABLE HOLES & NOTCHES SCALE: 1 " = 1 '-0" PANEL EDGE NAILING PER SHEAR WALL SCHEDULE W U N Z CO 0 ADJACENT NAILS IN A ROW ARE TO BE DRIVEN FROM OPPOSITE SIDES, TYP (3) STUDS MAX TO BE USED FOR BUILT-UP COLUMNS UNO ON PLANS 8" OC MAX SPACING BETWEEN ADJACENT NAILS IN A ROW STAGGER NAILS EA SIDE OF STUD WITH 1 1/2" EDGE DISTANCE. PROVIDE 0.148" x 3" NAILS FOR (2) STUDS & 0.207" x 4 1/2" NAILS FOR (3) STUDS. PROVIDE (1) ROW OF STAGGERED NAILING FOR 2x4 STUDS. PROVIDE (2) ROWS FOR 2x6 STUDS. TYPICAL BUILT-UP STUD COLUMN DETAIL SCALE. SIMPSON A35 AT EXT DBL TOP PLATE WALLS WITH SPANS PER TYP DETAIL GREATER THAN 6' (6) 0.131 "0 x 3" NAILS EA END TYPICAL WALL STUDS / I I till � AND NOTES PER PLAN PER PLAN OR NOTES J TYP BUILT-UP STUD NAILING (1) FULL HT STUD UNO ON PLANS CRIPPLE STUDS PER PLAN, OR COL/HOLDOWN SCHEDULES. NOTES, OR COL SCHED TYPICAL HEADER DETAIL SCALE: 1 " = 1 '-0" NAILING PER BUILT-UP STUD DETAIL PANEL EDGE NAILING PER SW SCHEDULE WALL FRAMING, SHEATHING, AND NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP A. CORNER INTERSECTION B. 'T' INTERSECTION PANEL EDGE NAILING PER SHEAR WALL SCHEDULE NAILING PER BUILT-UP STUD DETAIL WALL FRAMING, SHEATHING, AND NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP TYPICAL SHEAR WALL INTERSECTION DETAIL SCALE: 1 " = 1 '-0" Z F�1 W W c\I Z W o --%w00% i � c �• I.. j a� C 3 3 V W O ca ul Q 0 N Z Q � W OBLD2023- O RECEI' Nov 22 U � CITY OF EDM DEVELOPMENT DEPARTME O p A ' & pF �PASk 4078 0 ` ORAL 5F'l �ti ONAL 0�l 26/ 23 REV. DATE DESCRIPTION 0 07126123 PERMIT SUBMITTAL PROJECT NO.: 23043.01 DESIGNED BY: LFM DRAWN BY: LFM CHECKED BY: CAB SHEET TITLE: WOOD FRAMING DETAILS 1461 VED 023 )NDS RVICES NT SHEET NO.: S4.1 DIAPHRAGM BOUNDARY 2x4 BLKG W/ SILL PLATE ROOF SHEATHING & NAILING PER PLAN NOTES. NAILING PER PLAN NOTES. NAILING OR FRAMING PROVIDE 8d @a 6" OC MIN. CLIP PER SW SCHED FULL DEPTH BLKG RIPPED TO MATCH SLOPE OF ROOF. TRUSS MFR TO PROVIDE TRUSS BLOCKING IF DEPTH AT WALL GREATER THAN 2x12 FRAMING. SILL PLATE NAILING PER i SW SCHED PRE-MFR ROOF TRUSS PANEL EDGE NAILING PER PER PLAN WITH (3) 10d 10d 8" OC, TYP TOE NAILS TO TOP SW SCHED TYP AT DBL PLATE. ROOF TOP PLATE SHEATHING & NAILING EXISTING FRAMING PER PLAN. PER PLAN NOTES. STUD FRAMING PER PLAN 2x4 CONTINOUS NAILER (a 24" OC OR NOTES. SHEATHING & SIMPSON TIE AT EACH W/ (2) 16d INTO EA TRUSS NAILING PER SW SCHED END OF TRUSS PER PLAN NOTES TRUSS BEARING WALL DETAIL SCALE: 1"= 1'-0" NOTE: 1. POSTS MAY BE INS7 EITHER SIDE OF RIN 2. REFER TO TYPICAL ( ELEVATION FOR AD INFORMATION NOT SPECIFICALLY CALL 3. REFER TO BOTH PAI PERPENDICULAR C( FOR INFORMATION. POST Ca) RIM PARALLEL TO JOIST TYPICAL GUARD SECTIONS SCALE: 1"= 1'-0" 4x4 GUARD POST PER TYPICAL GUARD ELEVATION. DO NOT NOTCH. RIM JOIST PER FRAMING PLAN DECK FRAMING PER PLAN 1800 LB TENSION STRAP EA SIDE OF BLKG 2x BLKG @a EA POST. ADD (3) 10d RING SHANK NAILS EA SIDE 2x CONT BLKG TO MATCH DEPTH OF TOP CHORD �a RIDGE PRE-MFR TRUSS OVER FRAMING 24" OC TRUSS OVERFRAMING DETAIL SCALE: 1 " = 1 '-0" EDGE BEAM PER FRAMING PLAN DECK FRAMING PER PLAN 1800 LB TENSION STRAP 0 JOIST. IF POST BTWN JOISTS, PROVIDE (1) STRAP �a EA ADJACENT JOIST POST Ca RIM PERPENDICULAR TO JOIST (2) 1 /2"O w/ WASHL..., ... TYPICAL GUARD ELEVATION SCALE: 1 " = 1 '-0" NOTE: 1. REFER TO ARCH DWGS & IBC FOR DIMENSIONAL TOLERANCES OF STAIRS & LANDINGS. 2. PROVIDE GUARD AND HANDRAILS AS REQUIRED PER IBC. 3. MAXIMUM STRINGER SPAN IS 8'-0". PROVIDE INTERMEDIATE SUPPORT WHERE SPANS EXCEED THIS. FRAMING PER PLAN 2x 12 NOTCHED STRINGER w/2x6 REINFORCEMENT p ° 2x BLKG EA STRINGER AT LANDINGS. ADD (3) 10d NAILS EA SIDE 2x6 TOP RAIL. ATTACH TO EA POST w/ (3) #12 x 3" SCREWS OR (3) 16d RING SHANK NAILS 2x4 TOP & BOT. ATTACH TO POST w/ (2) 8d RING SHANK NAILS OR (2) #8 x 2 1 /2" OR LONGER SCREWS NOTE: REFER TO TYPICAL GUARD SECTIONS FOR INFORMATION NOT CALLED OUT. 2x2 BALUSTER TYP 4x4 POST, TYP. DO NOT NOTCH CEDAR DECKING UNO BY OWNER RIM JOIST PER FRAMING PLAN TREAD & RISER PER ARCH. USE 2x12 NOTCHED STRINGER TREADS PER ARCH. 1 1/8" PLYWOOD TREAD UNO. W/2x6 REINFORCEMENT USE 1 1/8" PLYWOOD & 8' MAX SPAN TREAD UNO. 2x BLKG TIGHT TO STRINGERS PT 2x THRUST PLATE TIGHT TO 16" OC MAX UNO ON PLANS SIMPSON LSSU210-2 EA STRINGER STRINGER W/ (3) 10d TYP EA SIDE OF MID -SPAN BEAM EA STUD AT WALLS. WHERE APPLICABLE STRINGER 0 BEAM OR LANDING TYPICAL STAIR DETAILS SCALE: 1"= 1'-0" STRINGER SECTION STRINGERS. PROVIDE (2) HILTI X-DNI FASTENERS EA BLOCK w/ 2" MIN EMBED INTO FTG. Z � J coU STRINGER 0 LOWER LANDING 2x 12 NOTCHED STRINGER @a 16" OC MAX SPACING W/ 8' MAX SPAN. DO NOT OVERCUT TREAD OR RISER NOTCHES 2x6 SISTERED TO SIDE OF 2x 12 W/ (2) ROWS OF 10d NAILS STAGGERED 0 6" OC AS SHOWN FTG PER PLAN :6 c a) °` A 3 Q) a) uj V uj Q W 00 Q N Z O I�I11 11 W OBLD2023- O RECEI Nov 22 F• () Lu CITY OF EDM DEVELOPMENT: DEPARTME 0 z CL O A. OF WAS$ Hai sti �~ �sIWAL 01l2612� REV. DATE DESCRIPTION 0 07126123 PERMIT SUBMITTAL PROJECT NO.: 23043.01 DESIGNED BY: LFM DRAWN BY. LFM CHECKED BY: CAB SHEET TITLE: ROOF FRAMING DETAILS 1461 023 DNDS ERVICES NT SHEET NO.: S4.2