REVIEWED BLD2024-0316+Energy1+3.7.2024_3.43.53_PM+4112138BLD2024-0316 RECEIVED Simple Heating System Size: Washington State Mar 08 2024 This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA ci OF EDMONDS Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling IoEr PMENT SERVICES Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information MACHUGA ADDITION TO EXISTING HOUSE JEN & STEVEN MACHUGA 21227 96th Ave. W., Edmonds, WA 98020 Heating System Type: o All Other systems • Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) Seattle: Sea-Tac AP AT = Indoor (70 degrees) - Outdoor Design Temp A' ^F Buildina Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) Average Ceiling Height Instructions Average Ceiling Height (ft) Glazing and Doors Instructions u-o.za • Skylights Instructions Insulation Attic Instructions R-49 Single Rafter or Joist Vaulted Ceilings Instructions No Vaulted Ceilings in this project. Above Grade Walls (see Figure 1) Instructions R-21 Intermediate Floors Instructions R- 1a Below Grade Walls (See Figure 1) Instructions No Below Grade Walls in this project. Slab Below Grade (see Figure 1) Instructions No Slab Below Grade in this project. � molk— Slab on Grade (see Figure 1) Instructions No Slab on Grade in this project. Location of Ducts Instructions Conditioned Space Figure 1. Above Grade 1,281 9.0 U-Factor 0.280 Conditioned Volume 11,529 X Area = UA 411 115.08 U-Factor X Area = UA 0.50 12 6.00 U-Factor X Area = UA 0.026 1,319 34.29 U-Factor X Area UA U-Factor X Area UA 0.056 1,506 84.34 U-Factor X Area UA 0.025 1,319 32.98 U-Factor X Area UA 0.028 0� F-Factor X Length UA 0.303 0� --- F-Factor X Length UA Duct Leakage Coefficient 1.00 Sum of UA 46 REVIEWED BY CITY OF EDMONDS 272.69 Envelope Heat Load 12,544 Btu / Hour Sum of UA x AT Air Leakage Heat Load 5,728 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 18,271 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 18,271 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 22,839 Btu / Hour Buildinq and duct heat loss x 1.40 for forced air furnace Buildinq and duct heat loss x 1.25 for heat pump (07101113)