Loading...
REV1 APPROVED BLD BLD2024-0321+STRUCTURAL PLANS+7.5.2024_10.56.43_AM+4359720ABBREVIATIONS GENERAL A. B. ANCHOR BOLT (E) EXISTING INT. INTERIOR ADD'L ADDITIONAL EA. EACH JST. JOIST ALT. ALTERNATE E.S. EACH SIDE K KIPS (1000 POUNDS) APPRX. APPROXIMATE E.W. EACH WAY MFR. MANUFACTURERED ARCH. ARCHITECTURAL ELEV. ELEVATION (N) NEW MEMBER AT EQ. EQUAL N.S. NEAR SIDE BLDG. BUILDING EXIST. EXISTING N.T.S. NOT TO SCALE BOT. BOTTOM EXT. EXTERIOR O.C. ON CENTER BRG. BEARING FND. FOUNDATION O.H. OVERHANG B/W BETWEEN FLR. FLOOR It PLATE CANT. CANTILEVERED) FRM'G FRAMING QTY, QUANTITY CENTERLINE F.S. FAR SIDE REQ'd REQUIRED CLR. CLEAR FTG. FOOTING SIM. SIMILAR COL. COLUMN GWB GYPSUM WALL BOARD SQR. SQUARE CONT. CONTINUOUS HDR HEADER TPL. TRIPLE DBL. DOUBLE HORIZ. HORIZONTAL TYP. TYPICAL 0, DIA. DIAMETER IBC INTERNATIONAL BUILDING U.N.O. UNLESS NOTED OTHERWISE DIAG. DIAGONAL CODE VERT. VERTICAL W/ WITH CONCRETE AND MASONRY C.I.P. CAST IN PLACE E.J. EXPANSION JOINT P/T POST -TENSIONED C.J. CONTROL JOINT EMBD. EMBEDMENT) REINF. REINFORCEMENT CMU CONCRETE MASONRY UNIT LT. WT. LIGHT WEIGHT STIR. STIRRUP CONC. CONCRETE P/C PRECAST CONCRETE WWF WELDED WIRE FABRIC STEEL B.F. BRACED FRAME HSS HOLLOW STRUCT. SECTION WHS WELDED HEADED STUD GA. GAGE L ANGLE X-STG EXTRA STRONG GALV. GALVANIZED MRF MOMENT RESISTING FRAME XX-STG DOUBLE EXTRA STRONG Wnnn d PENNY (NAILS) HGR HANGER P.T. PRESSURE TREATED) D.F. DOUGLAS FIR LSL LAMINATED STRAND LUMBER SHTG SHEATHING GLB GLUE -LAMINATED BEAM LVL LAMINATED VENEER LUMBER SS SELECT STRUCTURAL H.F. HEM -FIR PSL PARALLEL STRAND LUMBER T&G TONGUE AND GROOVE Digitally signed by Joshua T Mergens DIN CN=Joshua T Mergens, O=Balanced Structural Engineering LLC, Joshua T Mergens SERIALNUMg.ER=-TL20230811310024, L=Olympia, S=Washington, C=US Date: 2024.07.05 10:40:44-07'00' STRUCTURAL NOTES 1.0 GENERAL STRUCTURAL NOTES: THESE STRUCTURAL NOTES SUPPLEMENT THE DRAWINGS. BASIS OF DESIGN IS DRAWINGS PROVIDED BY CLIENT. ANY DISCREPANCY FOUND AMONG THE DRAWINGS, THESE NOTES, AND THE SITE CONDITIONS SHALL BE REPORTED TO THE BALANCED STRUCTURAL ENGINEERING, LLC, WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING. ANY WORK DONE BY THE CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE CONTRACTOR'S OWN RISK. THE CONTRACTOR SHALL VERIFY AND COORDINATE THE DIMENSIONS AMONG ALL DRAWINGS PRIOR TO PROCEEDING WITH ANY WORK OR FABRICATION. THE CONTRACTOR IS RESPONSIBLE FOR ALL BRACING AND SHORING DURING CONSTRUCTION. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND ELEVATIONS. BALANCED STRUCTURAL ENGINEERING, LLC ASSUMES NO RISK FOR WORK PERFORMED ON SITE WHERE CONDITIONS VARY FROM PLAN. WATERPROOFING AND DRAINAGE IS THE RESPONSIBILITY OF THE CONTRACTOR AND IS NOT ADDRESSED IN ITS ENTIRETY IN THESE STRUCTURAL DRAWINGS. 1.1 CODES ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL JURISDICTION AND: THE 2018 INTERNATIONAL BUILDING CODE (IBC), AND 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) AS AMENDED AND ADOPTED BY THE LOCAL JURISDICTION AND THE STATE OF WASHINGTON. 1.2 DESIGN CRITERIA: A. DEAD LOADS ROOF 15 PSF FLOOR 15 PSF EXTERIOR WALL 12 PSF INTERIOR PARTITION 10 PSF CONCRETE 150 PCF B. LIVE LOAD IBC TABLE 1607.1 CONCENTRATED REDUCIBLE ROOF 20 PSF - YES FLOOR (RESIDENTIAL) 40 PSF 300# NO DECK/BALCONIES: 60 PSF 300# NO GUARD RAIL: 50 PLF 200# NO C. SNOW LOADS Pg Pf Is Ce Ct 25 PSF 25 PSF 1.0 1.0 1.1 FLAT ROOF SNOW LOAD, PF = 25 PSF (MIN PER SEAW WHITE PAPER) D. WIND LOADS V (ULT.), MPH V (ASD), MPH RISK CAT. EXPOSURE Kn 100 77 II B 1.0 a. WIND SPEEDS FOR 3-SECOND GUSTS b. SIMPLE DIAPHRAGM BUILDING, ENCLOSED E. SEISMIC LOADS SITE CLASS RISK CAT. SEISMIC IE SS S� Sps Spy Fa Fv CATEGORY D II D 1.0 1.280 0.450 1.024 0.555 1.200 1.850 LIGHT FRAME WOOD SHEAR WALLS R = 6.5 CS = SDS I E/R V=CSW V = 0.165W FOR LOAD FACTOR DESIGN V = 0.115W FOR ALLOWABLE STRESS DESIGN 1.3 SOIL: SOIL CAPACITY IS ASSUMED PER 2018 IBC TABLE 1806.3. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY THAT THE SITE SOILS PROVIDE THE MINIMUM BEARING CAPACITY. 1500 PSF, ASSUMED BEARING CAPACITY, 40 PCF, ACTIVE PRESSURE, 250 PCF, PASSIVE PRESSURE 0.45 COEFFICIENT OF FRICTION. 2.0 CONCRETE & REINFORCING STEEL: A. ALL CONCRETE WORK SHALL BE PER THE 2018 IBC CHAPTER 19 AND ACI 318-14. CONCRETE QUALITY, MIXING AND PLACEMENT SHALL BE PER ACI 318-14. MIXING AND PLACEMENT SHALL BE PER ACI 318-14 AND INSPECTIONS SHALL BE PER 2018 IBC, CHAPTER 19, SECTIONS 03 AND 04. B. CONCRETE SHALL BE IN ACCORDANCE WITH ASTM 150. F'a = 3000 PSI @ 28 DAY (FOR WEATHER PROTECTION) SLUMP = 4" MAXIMUM, 6% AIR ENTRAINED, W/C RATIO = 0.50 MAXIMUM. NO SPECIAL INSPECTION REQUIRED. C. ALL REINFORCING SHALL BE ASTM A615 GRADE 60 EXCEPT AS SHOWN ON THE PLANS. LAP ALL SPLICES A MINIMUM OF 48 BAR DIAMETERS OR 18". LAP HORIZONTAL STEEL AT CORNERS AND INTERSECTIONS IN FOOTINGS AND WALLS WITH CORNER BARS. MINIMUM CONCRETE COVER FOR REINFORCING STEEL: COVER CONDITION 3" CONCRETE CAST AGAINST EARTH 2" CONCRETE CAST AGAINST FORMS BUT EXPOSED TO EARTH 1-1/2" MAIN REINFORCING IN BEAMS 1-1 2 TO TIES IN COLUMNS AND TIED REBAR IN WALLS 2 FOR BARS IN SLABS ON GRADE E1-1 1-1 2 FOR BARS IN SLABS ON FORMS 3.0 CARPENTRY: A. FRAMING LUMBER - ALL LUMBER TO BE AS FOLLOWS UNLESS NOTED OTHERWISE. 2x & 4x BEAMS D.F. #2 OR BETTER U.N.O. 6X POSTS DF #1 OR BETTER U.N.O. 2x MEMBER SHALL BE KILN DRIED AND STORED IN A DRY AREA PRIOR TO INSTALLATION. B. GLUE LAMINATED BEAMS (GLB) GLUED LAMINATED BEAMS SHALL BE PER ANSI A190.1, AMERICAN NATIONAL STANDARDS FOR STRUCTURAL GLUED LAMINATED TIMBER. USE BALANCED GRADE DF 24F-V4, FB=2,400 PSI, FV=240 PSI. FOR CANTILEVERED OR MULTISPAN BEAMS USE DF 24F-V8. C. LAMINATED VENEER LUMBER (LVL� LAMINATED VENEER LUMBER SHALL BE D.F. PER THE REQUIREMENTS OF ASTM D2559 WITH GRAIN PARALLEL TO THE LENGTH OF MEMBER, FB=2,600 PSI, FV=285 PSI, E=2.0 x 106 PSI. D. PARALLEL STRAND LUMBER (PSL)- PARALLEL STRAND LUMBER SHALL BE MANUFACTURED PER THE REQUIREMENTS OF ASTM D2559 WITH GRAIN PARALLEL TO THE LENGTH OF MEMBER, FB=2,900 PSI, FV=290 PSI, E=2.0 x 10' PSI. E. LAMINATED STRAND LUMBER (LSL� LAMINATED STRAND LUMBER SHALL BE MANUFACTURED PER THE REQUIREMENTS OF ASTM D2559 WITH GRAIN PARALLEL TO THE LENGTH OF MEMBER, FB=1,700 PSI, FV=425 PSI, E=1.3 x 10' PSI. F. PLYWOOD/OSB SHEATHING: PLYWOOD SHALL BE NAILED 6" O.C. EDGES AND 12" FIELD WITH 8d'S UNLESS OTHERWISE NOTED. 3.1 PROTECTION AGAINST DECAY AND TERMITES: IBC 2304.11, WOOD USED ABOVE GROUND SHALL BE PRESSURE TREATED IN ACCORDANCE WITH AWPA U1 FOR THE FOLLOWING CONDITIONS: A. JOISTS, GIRDERS AND SUBFLOORS THAT ARE CLOSER THAN 18" TO EXPOSED GROUND IN CRAWL SPACES OR EXCAVATED AREAS LOCATED WITHIN THE PERIMETER OF THE BUILDING FOUNDATION. B. WOOD FRAMING INCLUDING SHEATHING THAT REST ON EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8 INCHES FROM EXPOSED EARTH. C. SLEEPERS, SILLS, LEDGERS, POSTS AND COLUMNS IN DIRECT CONTACT WITH CONCRETE OR MASONRY. ALL FIELD -CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE -TREATED WOOD SHALL BE TREATED, FOR USE CATEGORY UC4A PER AWPA U1-07, IN THE FIELD USING A 9.08% COPPER NAPHTHENATE (CUN) SOLUTION SUCH AS "END CUT SOLUTION" (CUNAPSOL-1) IN ACCORDANCE WITH THE PRODUCT MANUFACTURES DIRECTIONS. 3.2 HARDWARE: w Q 0 O z 0 W . � co W i N C) 0 � II­_00 a E Z U�Q � W 06 L.L 00 N z M 00 0 c ca . _ 00 0 W �/ 0 � L.L A P 5375�_crti /2 �ss`IONAL E��1 07/05/2024 DESIGNED BY: JTM DATE: 3/7/2024 (PROJECT #: 24012 1 ALL CONNECTION HARDWARE SHALL BE SIMPSON "STRONG TIE" OR AN APPROVED EQUAL, UNLESS NOTED OTHERWISE . CONNECTION HARDWARE EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND OR PRESSURE TREATED WOOD SHALL BE GALVANIZED PER ASTM A-123 WITH 1.25 OZ. OF ZINC SPELTER PER SQUARE FOOT OF CONTACT AREA. ANCHOR BOLTS IN PRESSURE -TREATED SILL PLATES SHALL NOT BE GALVANIZED. S1 ■ 3.3 PRE-ENGINEERED TRUSSES: A. TRUSSES ARE TO BE DESIGNED BY OTHERS AND STAMPED AND SEALED BY A LICENSED ENGINEER. TRUSS SHOP SHEET 1 OF DRAWINGS ARE TO BE PROVIDED TO THE ENGINEER OF RECORD FOR REVIEW BEFORE FABRICATION. 4.0 HAZARDOUS MATERIAL: BALANCED STRUCTURAL ENGINEERING ASSUMES NO RISK RELATED TO DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL, OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS OF ANY FORM. SHEET SIZE: 24" x 36" NOTES: 1. MAINTAIN 3/8" MIN EDGE DISTANCE FROM PLYWOOD SHEATHING TO NAILS 2. EDGE NAILING TO BE APPLIED TO EDGES, PROVIDE 2x4 D.F. #2 FL WHERE REQUIRED TO NAIL ALL E 3. PLACE LONG DIRECTION OF PLYW VERTICAL. 4. SEE 1/S1.3 FOR REMAINING 2x TRIMMER NAIL TO KING STUD W/ 10d's TO MATCH SHEAR WALL NAILING PATTERNS (TYP. ADDITIONAL #4X5'-0" CENTERED ON BOLT FOR HOLD DOWNS WITH CAPACITY GREATER THAN 10,000#, SEE TIE -DOWN TYPICAL WALL ELEVATION 3/8" =1 '-0" SHEAR WALL DFQ CrwFnI II D SHEAR WALL KIIAI DDR DI ANC DOWNS AND WHERE DBL. TIE -DOWN TRIMMERS ARE USED LOCATION NOTES: 1. GLUE FLOOR SHEATHING TO JOISTS WITH LIQUID NAILS SUBFLOOR & DECK CONSTRUCTION ADHESIVE OR OTHER APA APPROVED GLUE. 2. WHERE BLOCKING IS REQUIRED, PROVIDE 2X4 D.F. #2 FLAT BLOCKING BELOW SHEATHING @ RIM JOIST/BLOCKING UNSUPPORTED EDGES W/ EDGE NAILING PER PANEL BOUNDARY NAILING DETAIL A PER TABLE 3. NAILS SHALL BE MIN. 3/8" FROM PANEL EDGES s ITS---TI-----IT_ TT----/ TTj\----IT II rl II II FLOOR OR ROOF SHEATHING SEE TABLE ROOF AND FLOOR SHEATHING DETAIL -0" STUD GLUE AND NAIL WITH 10d's @ 8" O.C. WALL SHEATHING COMMON STUDS STUD GLUE AND NAIL WITH 10d's @ 8" O.C. PANEL EDGE NAILING WALL TO WALL STRAP LOCATION :(2) OLD DOWN LOCATION STUDS, GLUE AND NAIL WITH (2) ROWS OF 10d's @ 8" O.C. WALL CONTINUES IN SOME LOCATIONS HOLD DOWN AT INSIDE CORNER INTERMEDIATE FRAMING MEMBERS (FIELD NAILING) SHEAR WALL oro crurnl u r DBL TOP PLATE LAP DETAIL 5/S1.3 G STUD AS REQUIRED SHEAR WALL EGDE LING PATTERNS (TYP.) ROWS 16d's TO MATCH AR WALL EDGE NAILING DOWN PER )R PLAN F. SILL PLATE C STEM WALL FOOTING ER SHEAR WALL SCHEDULE DIAPHRAGM SHEATHING LEVEL SHEATHING EDGE NAIL BOUNDARY FIELD NAIL NAIL ROOF 1/2" PLY OR 7/16" OSB 8d @ 6" 8d @ 6" 8d @ 12" SPAN RATED 1fi O.C. O.C. O.C. FLOOR 3/4" PLY OR OSB SPAN 10d @ 6" 10d @ 6" 10d @ RATED 41 O.C. O.C. 12" O.C. BLOCKING AT UNSUPPORTED PANEL EDGES; NOT REQ'D UNLESS SPECIFICALLY NOTED ON FRAMING PLANS PANEL EDGE NAILING (STAGGER NAILING @ PANEL EDGES) WALL SH ROOF TRUSSES OR FLOOR JOISTS PER PLAN FLAT 2X4 (MIN) BLOCKING @ UNSUPPORTED PANEL EDGES; ONLY WHERE SPECIFIED ROOF OR FLOOR FRAMING MEMBER BLOCKING @ UNSUPPORTED PANEL EDGES �1GE NAILING PER TABLE PLYWOOD OR OSB SHEATHING STUD WITH (2) ROWS 10d's @ 8" O.C. PANEL EDGE NAILING (2) STUDS, GLUE AND NAIL WITH (2) ROWS OF 1Od's @ 8" O.C. `-HOLD DOWN LOCATION WALL TO WALL STRAP HOLD DOWN AT OUTSIDE CORNER STANDARD SHEAR WALL SCHEDULE 2" A.B." A.B. MARK MARKA SHEATHING AND NAILING CAPACITY SPACING SPACING CLIP SPACING U.N.O. U.N.O. U.N.O. 7/16" PLYWOOD OR OSB, BLOCKED, W/ RBC = 16" A 1F 8D NAILS @ 6" O.C. @ PANEL EDGES 260 PLF 48" O.C. 68" O.C. A35 OR LS70 = 30" AND @ 12" O.C. @ FIELD. HGA10KT = 48" (NOTE C) PLYWOOD OR OSB, BLOCKED, W/ RBC = 12" AA7/16" 8D NAILS @ 4" O.C. @ PANEL EDGES 380 PLF 32" O.C. 42" O.C. A35 OR LS70 = 16" AND @ 12" O.C. @ FIELD. HGA10KT = 36" (NOTE C) 7/16" PLYWOOD OR OSB, BLOCKED, W/ RBC = 8" W3 A A 8D NAILS @ 3" O.C. @ PANEL EDGES 490 PLF 25" O.C. 36" O.C. A35 OR LS70 = 16" AND @ 12" O.C. @ FIELD. SEE NOTE B HGA10KT = 30" (NOTE C) 7/16" PLYWOOD OR OSB, BLOCKED, W/ A35 OR LS70 = 12" W4 A A 8D NAILS @ 2" O.C. @ PANEL EDGES AND @ 12" O.C. @ FIELD. SEE NOTE B 640 PLF 19" O.C. 28" O.C. HGA10KT - 22" (NOTE C) 7/16" PLYWOOD OR OSB, BLOCKED, W/ A35 OR LS70 - 8" AZ5 10D NAILS @ 2" O.C. @ PANEL EDGES AND @ 12" O.C. @ FIELD. SEE NOTE B 770 PLF 16" O.C. 23" O.C. HGA10KT = 18" (NOTE C) 7/16" PLYWOOD OR OSB, BLOCKED, W/ (2) A35 = 6" A 6 A ROWS 8D NAILS @ 3" O.C. @ PANEL EDGES AND @ 12" O.C. @FIELD. SEE NOTE B 980 PLF 14" O.C. 20" O.C. HGA10KT = 14" (NOTE C) PLYWOOD OR OSB, BLOCKED, W/ (2) W7 A7/16" ROWS 10D NAILS @ 2" O.C. @ PANEL EDGES 1200 PLF 12" O.C. 17" O.C. HGA10KT = 10" (NOTE C) AND @ 12" O.C. @ FIELD. SEE NOTE B A. "W-F" INDICATES SHEAR WALL WITH OPENINGS. EDGE NAIL SHEATHING BOTH SIDES OF ALL OPENINGS AND ABOVE AND BELOW ALL OPENINGS. PROVIDE HORIZONTAL STRAPS & NAILING AT OPENINGS PER DETAIL 3/S1.3. B. WHERE INDICATED ABOVE, USE 3x SILL PLATES AT FOUNDATION AND USE 3x OR DBL 2x STUDS AT ALL ABUTTING PANEL EDGES. NAILS SHALL BE STAGGERED WHERE NAILS ARE SPACED AT 2" O.C. 3X SILL PLATES CAN BE A COMBINATION OF (1) PRESSURE TREATED 2x SILL DIRECTLY IN CONTACT WITH CONCRETE AND ANOTHER NON -TREATED 2x SILL PLATE NAILED TO THE LOWER PLATE WITH SEE NOTE 6 FOR STITCH NAILING. C. USE 3" SDS TO TOP PLATE WITH HGA10KT. AT TWO SIDED SHEAR WALLS PROVIDE TWICE AS MANY CLIPS SHEAR WALL NOTES CARPENTRY: SEE DETAIL 1 & 3/S1.3 1. WALL STUDS AT SHEAR WALLS SHALL BE D.F. #2 AND BE SPACED NO MORE THAN 16" O.C. 2. ALL WALL SHEATHING SHALL BE 1/2" CDX PLYWOOD, 5/8" T1-11 SIDING, OR 7/16" OSB WITH EXTERIOR EXPOSURE GLUE AND SPAN RATED 24/0 OR BETTER. ALL FREE SHEATHING EDGES SHALL BE BLOCKED WITH 2X4 OR 2X6 FLAT BLOCKING. 3. EXTEND SHEATHING UP TO DOUBLE TOP PLATES AND INSTALL NAILS THROUGH SHEATHING INTO UPPER TOP PLATE. 4. NAILS SHALL BE INSTALLED SO AS TO NOT SPLIT THE FRAMING MEMBERS. 5. MINIMUM NAIL SPACING IN A SINGLE ROW SHALL BE 4 INCHES ON CENTER. USE (2) ROWS IF SPACING LESS THAN 4" O.C.. OPTIONAL TO USE (2) 2x'S IN PLACE OF SINGLE 3x IN SHEAR WALLS W3, W4 AND W5 W/ STITCH NAILING, SEE NOTE 6. 6. STITCH NAILING SHALL BE (2) ROWS OF 10d's SPACED @ 10" O.C. FOR UP TO W3, 8" O.C. FOR W4, & 6" O.C. FOR W5. ANCHOR BOLTS: SEE DETAIL 6/S1.2 STANDARD TIE -DOWN TABLE EPDXIED ANCHORSA'B SIMPSON HOLDOWN CAPACITY (LB.) BOUNDARY ELEMENT TOTAL FASTENERS ANCHOR BOLT DIAMETER ANCHOR EMBEDMENT SIMPSON EPDXY EMBEDMENT LTT20B 1,500 (2) 2X_ (10) 16d 1/2" 8" 3G 8" HTT4 4,455 (2) 2X_ (18) 16d 5/8" 8" 3G 12" HTT5 4,670 (2) 2X_ (26) 16d 5/8" 8" 3G 12" HDU2 3,075 (2) 2X_ (6) 1/4"X3" SDS 5/8" 8" 3G 12" HDU4 4.565 (2) 2X_ (10) 1/4"X3" SDS 5/8" 8" 3G 12" HDU5 5,645 (2) 2X_ (14) 1/4"X3" SDS 5/8" 8" N/A N/A HDU8 7,870 (1) 4X_ (20) 1/4"X3" SDS 7/8" 12 N/A N/A HDU11 9,335 (1) 4X6 (30) 1/4"X3" SDS 1" 12" N/A N/A HDU14 14,445 (1) 6X6 (36) 1/4"X3" SDS 1" 12" N/A N/A HDQ8 9,230 (1) 4X_ (20) 1/4"X3" SDS 7/8" 12 N/A N/A HHDQ11 11,810 (1) 4X6 (24) 1/4"X3" SDS 1" 12" N/A N/A HHDQ14 13,710 (1) 6X6 (30) 1/4"X3" SDS 1" 12" N/A N/A STRAPS: FLOOR TO FLOOR MST37 2,272 2 2X_ 22 16d N A N A N A N A MST48 3,528 2 2X_ 34 16d N A N A N A N A 2 MST48 7,056 1 6X6 68 16d N A N A N A N A MST60 5,237 2 2X_ 46 16d N A N A N A N A 2 MST60 10,474 1 6X6 92 16d N A N/A N/A N A A. EPDXIED ANCHORS ARE TO BE IN A CLEAN HOLE DRILLED 1/8" LARGER THAN THE ANCHOR BOLT DIAMETER. B. THREADED ROD ANCHORS SHALL BE ASTM A307 OR ASTM F1554 U.N.O. ('_��SHEAR-WALL &TIE -DOWN SCHEDULES 1 "=1'-0" NOTE: 1. ALL ANCHORS SHALL BE PER SHEAR WALL 1 UNLESS NOTED OTHERWISE, SEE 3/S1.2 FOR MAXIMUM SPACING AT SHEAR WALLS. 2. CAST -IN PLACE J BOLTS SHALL BE EMBEDDED 7" INTO THE STEM WALL AND PROJECT 3". 3. NOTCH RIM JOIST AT ANCHOR BOLT WHERE REQUIRED. 4. INSTALL STANDARD CUT WASHERS BETWEEN NUT AND BEARING PLATES WHEN SLOTTED BEARING PLATE IS USED. 5. POST INSTALLED EXPANSION ANCHORS SHALL BE INSTALLED WITH A 1 /2" 0 BIT FOR 1 /2"0 ANCHORS AND A 5/8" 0 BIT FOR 5/8" 0 DIAMETER ANCHORS 6. AN ANCHOR BOLT SHALL BE PLACED WITHIN 12" FROM CORNERS, AND 12" FROM THE ENDS OF BOTH SILL PLATES AT SPLICES. MUDSILL CAST -IN PLACE POST INSTALLED ANCHORS THICKNESS 307 J-BOLTWEDGE-ALL SIMPSON HOLE DEPTH „ 1/2" x 10" 1/2" x 6" 1-1 /2 5„ 5/8" x 10" 5/8" x 6" „ 2-1/2" 1/2" x 12" 1 /2" x 6 " 4-1/2" 5/8" x 12" 5/8" x 6 �„ 1/2" x 12" 1/2" x 8" 3" 5-1/2" 5/8" x 12" 5/8" x 8" 21„ 2 ANCHOR BOLT 2" MAX FOR STANDARD CUT WASHER (ONLY IF SHEAR WALL 3V1 .,a- USING SLOTTED BEARING PLATE) AND ABOVE 3"X3"XO.229" STANDARD OR SLOTTED BEARING CLIP I� a SEE FDN. DETAIL ANCHOR BOLTS J co J W cz I Y � U TOP REINFORCING GENERAL NOTES 1. DIMENSIONS SHOWN ARE TO BE FIELD VERIFIED BY THE CONTRACTOR. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF BALANCED STRUCTURAL ENGINEERING, LLC TO REMEDY ANY CONFLICTS. ANY WORK COMPLETED AFTER SUCH DISCOVERY WITHOUT WRITTEN DIRECTION FROM BALANCED STRUCTURAL ENGINEERING, LLC IS AT THE RISK OF THE CONTRACTOR. 2. SEE 6/S1.3 FOR TYPICAL BAR BENDS, SPLICES, AND CORNER REINFORCEMENT. 3. SEE 8/S1.3 FOR STEPPED FOOTINGS IF REQUIRED. 4. REFER TO FRAMING PLANS FOR HOLD DOWN LOCATIONS. CONTRACTOR IS TO COORDINATE HOLD DOWN ANCHOR BOLT LOCATIONS PRIOR TO CONCRETE POUR. 5. TEMPORARY SHORING AND EXCAVATIONS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 6. SEE ARCHITECTURAL PLANS FOR TOP OF WALL HEIGHTS AND PLAN DIMENSIONS. WHERE DIMENSIONS ARE SHOWN ON THE STRUCTURAL PLANS, CONTRACTOR SHALL VERIFY COMPATIBILITY WITH ARCHITECTURAL PLANS. WHERE DISCREPANCY EXISTS, CONTRACTOR SHALL NOTIFY BOTH THE ENGINEER AND ARCHITECT FOR CLARIFICATION. 7. FLOOR/ROOF JOIST AND TRUSS LOCATIONS ARE SCHEMATICALLY SHOWN ON THE PLANS. IT IS NOT THE INTENT OF THE STRUCTURAL PLANS TO GRAPHICALLY LOCATE ALL FRAMING MEMBERS. THE CONTRACTOR SHALL VERIFY THE COMPATIBILITY OF JOIST LAYOUT AND FRAMING W/ MECHANICAL, ELECTRICAL, AND PLUMBING. THE CONTRACTOR IS RESPONSIBLE FOR SPACING FRAMING MEMBERS AS NOTED ON THE PLANS AND GENERATING MEMBER LAYOUT FOR SHOP DRAWINGS AND QUANTITY TAKEOFFS. 8. THE DOUBLE TOP PLATE IS TO BE CONTINUOUS ALONG ALL EXTERIOR WALLS AND AT ALL INTERIOR SHEAR WALLS. TYPICAL WALL TOP PLATE SPLICES SHALL BE PER DETAIL 5/S1.3 TYP. 9. PROVIDE WALL BLOCKING FOR ALL WALL MOUNTED EQUIPMENT (SUCH AS TOWEL BARS, GRAB BARS, TOILET PAPER HOLDERS, DOOR STOPS, ETC.) 10. SIMPSON STRONG TIE PRODUCTS ARE CALLED OUT ON THE DRAWINGS. HOWEVER, SUBSTITUTES MAY BE PRESENTED TO THE FOR FOR APPROVAL. 11. TRUSS MANUFACTURER IS RESPONSIBLE FOR ALL TRUSS MEMBERS INCLUDING MECHANICAL CONNECTIONS OF THE TRUSS MEMBERS, TEMPORARY AND PERMANENT BRACING REQUIREMENTS, AND TRUSS CONNECTIONS TO GIRDER TRUSS. 12. TRUSSES DESIGNATED AS DRAG TRUSSES SHALL BE DESIGNED FOR A UNIFORM LOAD OF 240 POUNDS PER LINEAL FOOT (PLF) OF TRUSS. 13. SEE GENERAL STRUCTURAL NOTES ON S1.1 FOR ADDITIONAL INFORMATION. TYPICAL WALL FRAMING: 1. EXTERIOR WALLS: STUDS SHALL BE 2x6 D.F. #2 AT 16" O.C. WITH DOUBLE 2x6 WALL TOP PLATES U.N.O.. 2. INTERIOR WALLS: STUDS SHALL BE 2x4 D.F. #2 AT 16" O.C. WITH DOUBLE 2x4 WALL TOP PLATES U.N.O.. NAIL SIZE NAMING CONVENTION PENNY WEIGHT DIAMETER (INCHES) LENGTH (INCHES) 8d 0.131 2-1/2 10d 0.148 3 16d 0.148 3-1 /4 3"-8d 0.131 3 10d BOX 0.128 3 16d COMMON 0.165 # # - DETAIL NUMBER SX.X SX.X - SHEET NUMBER TYPICAL SHEAR WALL CALLOUT, W# SEE 3/S1.2 FOR SHEAR SCHEDULE EXTENT OF SHEAR WALL ON SHEAR PLANS OR EXTENT OF BEARING WALL ON FRAMING PLANS HOLD DOWN (HD) CALLOUT. SEE 2/S1.3 FOR WALL TO WALL STRAP TIES, SEE 3/S1.2 FOR HOLD DOWN REQUIREMENTS AT FOUNDATION, SEE �oPO �oPO 4 & 5/S1.2 FOR HOLD DOWNS AT WALL INTERSECTIONS AND WALL CORNERS. *INDICATES HOLD DOWN TO FOUNDATION -INDICATES WALL TO WALL STRAP TYPICAL HANGER SYMBOL POST CAP OR TOP CLIPS Qp5��0P POST BASE OR BASE CLIPS Qo 44 POST SIZE; SPECIES IS D.F. #2 U.N.O. TYPICAL POST CALLOUT SPECIES; D.F. #2 U.N.O. 3-1/2"x5-1/2" GLB r(1)K1(1)T SIZE; NOMINAL SIZES ARE WRITTEN WITHOUT INCH (")MARKERS # OF KING STUDS & TRIMMERS TYPICAL BEAM CALLOUT (1)K/(1)T ON ALL HEADERS U.N.O. BEAM/HEADER DRAG STRUT FLOOR JOIST PRE MFR. TRUSSES ROOF RAFTER STANDRD SYMBOLS & LINE TYPES 1 "=1'-0" � % 1 "=1'-0" � v l 1-1 /2"=1'-0" NTS 2 O 0 a) U w m LLi cn r-i V) -0 r-i cu u m m co CO Ln CO N o c w Q 0 VJ c: J O Q .U) CO Co W > N 0 O (f) rn a 06 U � < N 0) �000000000 �or- Q 06 W Nz O CO 00 O Z V 0 ~ 00 W O U L n w_� ad0"', A P 53755 Off, � �SsjO�1 07/05/2024 DESIGNED BY: JTM DATE: 3/7/2024 PROJECT #: 24012 S102 SHEET 2 OF 8 SHEET SIZE: 24" x 36" MINIMUM FASTENING SCHEDULE ELEMENT/CONNECTION FASTENER OPTIONS LOCATION ROOF 1. BLOCKING BETWEEN CEILING JOISTS, (3) 8d TOENAIL EACH END RAFTERS OR TRUSSES TO TOP PLATE OR (3) 10d BOX OTHER FRAMING BELOW (3) 3"-8d 2. BLOCKING BETWEEN RAFTERS OR TRUSS (2) 8d TOENAIL EACH END NOT AT THE WALL TOP PLATE, TO RAFTER (2) 3"-8d OR TRUSS (3) 3"-8d END NAIL 3. FLAT BLOCKING TO TRUSS AND WEB (3) 3"-8d's @ 6" o.c. FACE NAIL FILLER 4. BLOCKING BETWEEN CEILING JOISTS, (3) 8d TOENAIL EACH JOIST RAFTERS OR TRUSSES TO TOP PLATE OR (3) 10d BOX OTHER FRAMING BELOW (3) 3"-8d 5. CEILING JOISTS TO TOP PLATE (3) 8d TOENAIL EACH JOIST (3) 10d BOX (3) 3"-8d 6. CEILING JOIST NOT ATTACHED TO PARALLEL (4) 10d BOX FACE NAIL RAFTER, LAPS OVER PARTITIONS (NO (4) 3"-8d THRUST) 7. CEILING JOISTS ATTACHED TO PARALLEL (2) 10d FACE NAIL RAFTER (HEEL JOINT) 8. RAFTER OR ROOF TRUSS TO TOP PLATE (3) 10d TOENAIL (3) 16d (3) 10d BOX (4) 3"-8d WALL 9. STUD TO STUD (NOT AT SHEAR WALLS) 10d BOX 16" O.C. FACE NAIL 3" 8d 10. STUD TO STUD AND ABUTTING STUDS AT 10d 12" O.C. FACE NAIL INTERSECTING WALL CORNERS (AT BRACED WALL PANELS) 3"-8d 12" O.C. FACE NAIL 11. BUILT-UP HEADER 16d COMMON 16" O.C. EACH EDGE, FACE NAIL 16d 12" O.C. EACH EDGE, FACE NAIL 12. CONTINUOUS HEADER TO STUD (4) 8d TOENAIL (4) 10d BOX 13. TOP PLATE TO TOP PLATE 16d COMMON 16" O.C. FACE NAIL 10d BOX 12" O.C. FACE NAIL 3"-8d 14. TOP PLATE TO TOP PLATE, AT END JOINTS (8) 16d COMMON EACH SIDE OF END JOINT, FACE 115. (12) 1Od BOX NAIL (MIN 24" LAP SPLICE LENGTH (12) 3"-8d EACH SIDE OF END JOINT) BOTTOM PLATE TO JOIST, RIM JOIST, BAND 16d common 16" O.C. FACE NAIL JOIST OR BLOCKING (NOT AT BRACED WALL PANELS) 16d box 3"xO.131" nails 12" O.C. FACE NAIL 17. BOTTOM PLATE TO JOIST, RIM JOIST, BAND 2-16d common JOIST OR BLOCKING AT BRACED WALL 3-16d box 16" O.C. FACE NAIL PANELS 4-3"x0.131" nails 18. STUD TO TOP OR BOTTOM PLATE (4) gd TOENAIL (4) 10d BOX (4) 3"-8d (2) 16d COMMON END NAIL (3) 10d BOX (3) 3"-8d 19. TOP OR BOTTOM PLATE TO STUD 2-16d common END NAIL 3-1Od box 3-3"x0.131" nails 20. TOP PLATES, LAPS AT CORNERS AND 2-16d common FACE NAIL INTERSECTIONS 3-1Od box 3- 3"xO.131" nails 21 • 1 " BRACE TO EACH STUD AND PLATE 2-8d common FACE NAIL 2-1Od box 2- 3"xO.131" nails 22• 1 "x6" SHEATHING TO EACH BEARING 2-8d common FACE NAIL 2-1Od box 23• 1"X8"AND WIDER SHEATHING TO EACH 3-8d common FACE NAIL BEARING 3-1Od box FLOOR 24. JOIST TO SILL, TOP PLATE, OR GIRDER 3-8d common TOENAIL 3-10d box 3-3"xO.131 " nails 25. RIM JOIST, BAND JOIST, OR BLOCKING TO 8d 6" O.C., TOENAIL TOP PLATE, SILL OR OTHER FRAMING 10d BOX BELOW 3"-8d 26. 1 "x6" SUBFLOOR OR LESS TO EACH JOIST (2) 8d FACE NAIL (2) 10d BOX 27. 2" SUBFLOOR TO JOIST OR GIRDER (2) 16d COMMON FACE NIAL 28. 2" PLANK (2) 16d COMMON EACH BEARING, FACE NAIL 29. BUILT UP GIRDERS AND BEAMS, 2" LUMBER 10d BOX 24" O.C. FACE NAIL AT TOP AND LAYERS 3"-81D BOTTOM STAGGERED ON AND, OPPOSITE SIDES (3) 10d BOX ENDS AND AT EACH SPLICE, (3) 3"-8d FACE NAIL 30. LEDGER STRIP SUPPORTING JOISTS OR (3) 16d COMMON EACH JOIST OR RAFTER, FACE NAIL RAFTERS (4) 10d BOX (3) 3"-8d 31. JOIST TO BAND JOIST OR RIM JOIST (3) 16d COMMON END NAIL 132. (4) 10d BOX (4) 3"-8d BRIDGING OR BLOCKING TO JOISTS, (2) 8d EACH END, TOENAIL RAFTERS, OR TRUSSES (2) 10d BOX (2) 3"-8d NOTES: SEE 1/S1.2 FOR REMAINING CD z z w a 0 CD 0 0 0 0 FLOOR JOISTS TYPICAL TYPICAL WALL ELEVATION 3/8" =1 '-0" JI ILC\I\ IPC\LL LLIVV I I I A HEADER KING STUD TRIMMER STUD SILL A DOOR ROUGH OPENING HEADER WINDOW ROUGH OPENING 11 WALL SHEATHING SHALL BE EDGE NAILED INTO KING STUD COMMON STUD----,,,, FLOOR SHEATHING c=a HEADER o c� z o a_ SILL PLATE PROVIDE SOLID BLOCKING WHERE DOUBLE TRIMMERS, DOUBLE KING STUDS, OR HOLD DOWNS ARE SPECIFIED AND BENEATH POSTS, SIMILAR BETWEEN FLOORS BLOCKING, MAY BE FLAT OR PARALLEL TO SILLS SIMPSON STRAP STRAP CONNECTION DBL TOP PLATE SECTION A NTS CRIPPLE STUDS �SIMPSON CS16 TOP AND BOTTOM OF LARGEST WINDOW OPENING (CS14 WHERE INDICATED ON PLANS), NAIL TO HEADER AND FULL DEPTH 2X BLOCKING, STRAP MAY �BE ON WALL SHEATHING OR INTERIOR FACE COMMON STUDS NAIL COIL STRAP TO SILL AND FLAT 2X4 BLOCKING, STRAP MAY BE ON WALL SHEATHING OR EDGE NAIL SHEATHING TO BLK'G WHERE STRAP IS INSTALLED ON INTERIOR FACE. WALL CRIPPLE TIE -DOWN BOTTOM STUDS PER PLATE PLAN " SHEAR WALL WITH OPENINGS 1 /2" =1 '-0" BEND DIA. 4d d MIN. U.N.O. 180 DEGREE BEND 90 DEGREE BEND 135 DEGREE BEND NOTES: STRAPS TO RUN CONTINUOUS ACROSS ENTIRE SHEAR WALL EXTENT, NAIL WITH 8d's 0 EVERY OTHER HOLE, STAGGERED EDGE NAIL ALL SHEATHING AT ALL LOCATIONS ON SHEAR WALL PER SHEAR WALL CALLOUT. SEE TYPICAL SHEAR WALL ELEVATION FOR ATTACHMENT TO FOUNDATION 6ENp p\P BEND DIA. 1� OFFSET BEND 1 FOUNDATION REINFORCING BAR BENDS BAR BEND DIA. �4 � 1 /2>, #5 2 1/2" #6-#8 6d d = BAR DIAMETER DBL 2x TOP PLA 2x STUDS PER PLAN FULL HEIGHT STUD AT EA. SIDE OF BEAM; ATTACH WITH (4) 10d's BEAM PER PLAN) TRIMMER STUDS PER PLAN CORN EACH ALTEF OPENING SIMPS -# TRIMMERS & # KING FOR S STUDS PER HEADER & BEAM CALLOUTS EACH SIDE OF OPENING CRIPPLE STUD, TYP. ABOVE AND BELOW OPENING DBL E -2x PLATE CONT. BETWEEN TO RI DOOR OPENING OR 16' MIN STRAF P.T. SILL PLATE �CONC STEM WALL AND FOOTING BEAM PER PLAN/- WHERE BEAM BREAKS TOP PLATE; USE SIMPSON MST27 FOR PLATE SPLICE USE BUILT UP STUDS FOR FULL BEARING WITH SHIM AS REQUIRED STRAP PER PLAN WHERE REQUIRED; DBL 2x TOP PLATES MAYBE PLACED ON TOP OF TOP PLATES & BEAM ,( FULL HEIGHT STUD AT END OF BEAM; ATTACH TO BEAM USING (4) 1Od's TYPICAL BEAM POCKET DETAIL 15" MIN. TYP. ALL nnr)klC'CI CIAC1 CMI InrC` NOTES: 1. CORNER BARS ARE SAME SIZE AND SPACING AS HORIZ REINF 2. REINF AT ALL WALL CORNERS, ENDS AND INTERSECTIONS SHALL BE FABRICATED AND PLACED IN ACCORDANCE WITH APPROPRIATE DETAIL SHOWN. 3. WALL DETAILS SHOWN; FTG DETAILS SIMILAR. 4. VARIOUS CONDITIONS SHOWN; CORNER, INTERSECTION, AND WALL END. REINF. AT CORNERS, INTERSECTIONS, & WALL ENDS ON STRAP SEE PLANS BOTTOM PLAT IZE AND LOCATION ---\ zz FLOOR SHEAT TYP RIM JOIE OF STRAP o° '<'------ (LOCKING NEXT b° M JOIST ® I ° FLOOR JOIST LOCATIONS I ° (JOIST MAY DBL TOP P 7::1___WALL SHEATH HING SEE PLAN T BEYOND RIM JOIST. RUN OPP. DIRECTION) LATE ING SEE SHEAR SCHEDULE z O v� FOR MINIMUM STUD VWALL FRAMING REQUIREMENTS SEE PLAN 2 y��L TO WALL STRAP HOLD DOWN 4'-0" LAP MIN. TOP PLATE SPLICE NAILING HOLD DOWN PER ANCHOR PER TIE -DOWN SCHEDULE-\ DBL TOP PLATE FLOOR JOISTS BEYOND, MAY RUN OPP. DIRECTIO THREADED COUPLER- VJ __J O Q (10 W N 0 ' 00 U) CZ U =� Q� ui O4 ca N z O CO 00 O Cu Z V 0 ~ __J -E5 W O L_ L U n 0 2x6 PONY WALL z WITH STUDS ® NAIL SHEATHING TO MATCH T �I� N 16" O.C. SHEAR WALL TYPE ABOVE of dj�G w 24" LAP oLIS TYP L�E:P:� i IC f STEMWALL W/ VERT REINF PER DETAILS 53755 q (NOT SHOWN FOR CLARITY) s10 L�1��� 4 -0 MIN L. TOP OF %\� 07/05/2024 FOOTING DESIGNED BY: JTM x CD p //\ N a, 2 3" CLR STEPPED FOUNDATION FIRM SOIL UNDISTURBED DATE: 3/7/2024 PROJECT #: 24012 FOOTING THICKNESS TYP LONGITUDINAL FIG REINFORCEMENT S103 SHEET 3 OF 8 SHEET SIZE: 24" x 36" HING SEE PLAN T BEYOND RIM JOIST. RUN OPP. DIRECTION) LATE ING SEE SHEAR SCHEDULE z O v� FOR MINIMUM STUD VWALL FRAMING REQUIREMENTS SEE PLAN 2 y��L TO WALL STRAP HOLD DOWN 4'-0" LAP MIN. TOP PLATE SPLICE NAILING HOLD DOWN PER ANCHOR PER TIE -DOWN SCHEDULE-\ DBL TOP PLATE FLOOR JOISTS BEYOND, MAY RUN OPP. DIRECTIO THREADED COUPLER- VJ __J O Q (10 W N 0 ' 00 U) CZ U =� Q� ui O4 ca N z O CO 00 O Cu Z V 0 ~ __J -E5 W O L_ L U n 0 2x6 PONY WALL z WITH STUDS ® NAIL SHEATHING TO MATCH T �I� N 16" O.C. SHEAR WALL TYPE ABOVE of dj�G w 24" LAP oLIS TYP L�E:P:� i IC f STEMWALL W/ VERT REINF PER DETAILS 53755 q (NOT SHOWN FOR CLARITY) s10 L�1��� 4 -0 MIN L. TOP OF %\� 07/05/2024 FOOTING DESIGNED BY: JTM x CD p //\ N a, 2 3" CLR STEPPED FOUNDATION FIRM SOIL UNDISTURBED DATE: 3/7/2024 PROJECT #: 24012 FOOTING THICKNESS TYP LONGITUDINAL FIG REINFORCEMENT S103 SHEET 3 OF 8 SHEET SIZE: 24" x 36" 0 2x6 PONY WALL z WITH STUDS ® NAIL SHEATHING TO MATCH T �I� N 16" O.C. SHEAR WALL TYPE ABOVE of dj�G w 24" LAP oLIS TYP L�E:P:� i IC f STEMWALL W/ VERT REINF PER DETAILS 53755 q (NOT SHOWN FOR CLARITY) s10 L�1��� 4 -0 MIN L. TOP OF %\� 07/05/2024 FOOTING DESIGNED BY: JTM x CD p //\ N a, 2 3" CLR STEPPED FOUNDATION FIRM SOIL UNDISTURBED DATE: 3/7/2024 PROJECT #: 24012 FOOTING THICKNESS TYP LONGITUDINAL FIG REINFORCEMENT S103 SHEET 3 OF 8 SHEET SIZE: 24" x 36" STEMWALL W/ VERT REINF PER DETAILS 53755 q (NOT SHOWN FOR CLARITY) s10 L�1��� 4 -0 MIN L. TOP OF %\� 07/05/2024 FOOTING DESIGNED BY: JTM x CD p //\ N a, 2 3" CLR STEPPED FOUNDATION FIRM SOIL UNDISTURBED DATE: 3/7/2024 PROJECT #: 24012 FOOTING THICKNESS TYP LONGITUDINAL FIG REINFORCEMENT S103 SHEET 3 OF 8 SHEET SIZE: 24" x 36" p 0 0 0 0 0 0 0 0 0 0 0 LJI ------------------------------------jLJI I I I I I I I❑ I I I NO STRUCTURAL WORK TO BE DONE I I I I I I _ ----------J------------------------------------J I FF ❑ a ❑ n I FFF - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I I I ® I I I I I I I I I I I I I I I I I I I I I I I I I In NO STRUCTURAL WORK TO BE I I DONE I 'HI I I I I I I I I Ill n NO STRUCTURAL WORK TO BE DONE r -1 F_ r5 I I I I I I I I I I I 1 Y I c ------------------------------------------�--- - ----- ---+ - — = =- 7- L_ J FOUNDATION PLAN 1 /4" = V-0" (N) 2x6 INFILL STUD WALL L- I I In, I C I n PLAN NOTES: ALL BEAMS ARE 46 U.N.O. ALL HEADERS/BEAMS/COLUMNS SPECIES ARE D.F.#2 U.N.O ALL HARDWARE IS SIMPSON STRONG —TIE. VERIFY SLOPE, SKEW, CONCEALED FLANGE, OR OTHER HARDWARE OPTIONS PRIOR TO ORDERING. SEE S1.1, S1.2, & S1.3 FOR ADDITIONAL NOTES, DETAILS, AND LEGENDS. SEE SHEAR PLANS FOR HOLD DOWN LOCATIONS O Ov a) U w mLucn L/) -0 cu u mC fu cu ro m ra Ln co N — c z 0 w z Q U J F_ LLJ F_ cli �J O N Q 0 z 0 .� c Z C 0 � Q E Z U=� co oc)c Q (� Co N 00 z 0 0 d� co Z D ._ 00 o 0 O LL H n ECG 07/05/2024 DESIGNED BY: JTM DATE: 3/7/2024 PROJECT #: 24012 S201 SHEET 4 OF 8 SHEET SIZE: 24" x 36" m I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I \ SKYLIGHT LOC PER ( OWNER/CONTRACTOR (E) 2x4 STUD WALLS FURRED TO 2x6 Nom Y I � X O Ov a) U w mLucn L/) -0 cu u mC fu cu ro m ra Ln m m N O NO STRUCTURAL WORK TO BE DONE — rF - IV _�F El El ----------------0------ ----L— / \ I I I I I Sim. 1 �1 JI O S4.2 6 O O,o F���o� c�°'f'O \ I F� s \ ROOF FRAMING PLAN 1 /4" = V-0" (N) 2x4 INFILL STUD WALL 11 I I 4x8(2)K/(1)T (N) 2x4 INFILL STUD WALL C C C u n -7 F_ -1 H F NO STRUCTURAL WORK TO BE DONE II C- (N) 2x6 INFILL STUD WALL n u r� j � PLAN NOTES: ALL BEAMS ARE 46 U.N.O. ALL HEADERS/BEAMS/COLUMNS SPECIES ARE D.F.#2 U.N.O ALL HARDWARE IS SIMPSON STRONG -TIE. VERIFY SLOPE, SKEW, CONCEALED FLANGE, OR OTHER HARDWARE OPTIONS PRIOR TO ORDERING. SEE S1.1, S1.2, & S1.3 FOR ADDITIONAL NOTES, DETAILS, AND LEGENDS. SEE SHEAR PLANS FOR HOLD DOWN LOCATIONS Z O � w z Q U J w N w O N Q N 0 O Z c: O Z . co � Q J ' N C/) 00 U cn Q � Z 00 G N Z (� 00 O M LL 2 F— LL ._ 00 0 w 0� O O LLO T At ASS • Ip l� Ste�j P 53755 crti /i �SsjONAL E��1 07/05/2024 DESIGNED BY: JTM DATE: 3/7/2024 PROJECT #: 24012 S202 SHEET 5 OF 8 SHEET SIZE: 24" x 36" 6 NO STRUCTURAL WORK TO BE DONE El El tj I I� I i i - I L FIRST LEVEL SHEAR PLAN 1 /4" = V-0" 0 0 0 EF-1 C C C u n� -1 F_ -1 H F H F1 NO STRUCTURAL WORK TO BE DONE II � II I II II F1 u r� j � PLAN NOTES: ALL BEAMS ARE 46 U.N.O. ALL HEADERS/BEAMS/COLUMNS SPECIES ARE D.F.#2 U.N.O ALL HARDWARE IS SIMPSON STRONG —TIE. VERIFY SLOPE, SKEW, CONCEALED FLANGE, OR OTHER HARDWARE OPTIONS PRIOR TO ORDERING. SEE S1.1, S1.2, & S1.3 FOR ADDITIONAL NOTES, DETAILS, AND LEGENDS. SEE SHEAR PLANS FOR HOLD DOWN LOCATIONS O Ov a) U w mLucn L/) -0 u � mC fu c2 ro M cB m Lnm�N O C w CD Q U J F_ CLJ W N �J O CD O z z c: Q O . U) co ^J 1..� / o vJ 00 (n Lu U I__00 � < a) co_ �U) � 00 06 Ca co N 00 z Qco W i (� � 00 o 1.LLJ ._ w O LL LL T M� �P 5375�_crti �SsjONAL E��1 07/05/2024 DESIGNED BY: JTM DATE: 3/7/2024 PROJECT #: 24012 S301 SHEET 6 OF 8 SHEET SIZE: 24" x 36" 2x2 ATTACHED TO (E)2x4 STUDS W/ #8x3" WOOD SCREWS & 8" O.C. WALL SHEATHING, SEE SHEAR SCHEDULE 2x6 BLOCKING PLATE W/ 16d's TO MATCH SHEAR WALL EDGE NAIL SPACING PANEL EDGE NAILING (E)2x4 PLATE VERIFY AB'S OR PROVIDE (2) ROWS OF "x3" CONCRETE SCREWS @ 12"O.0 FLOOR ASSEMBLY ATTACHMENT PER 6/S4.1 I L `4�: ------ (E)4" CONC SLAB I� (E)FTG I I I I �J L� TYPICAL CONCRETE FOOTING 1 "=1'-0" ,.,— (E)2x6 STUD WALL MILL SHEATHING, ;EE SHEAR SCHEDULE PANEL EDGE NAILING 2x6 STUD WALL INFILL AT (E)GARAGE OPENING WALL SHEATHING, SEE SHEAR SCHEDULE 2x6 SILL PALTE W/ 16d's TO MATCH SHEAR WALL EDGE NAIL SPACING PANEL EDGE NAILING — PT 2x6 W/ (2) ROWS OF Y4" Ox3" CONCRETE SCREWS @ 12"O.C. FLOOR ASSEMBLY ATTACHMENT PER 6/S4.1 1 I �-------- I (E)4" CONC SLAB 1 I I (E)FTG I I I �J L� 01• 1 TYPICAL CONCRETE FOOTING AT 2x6 GARAGE INFILL 1 "=1'-0" PT 2x4 #24"O.C. W/ (2) ROWS OF Y4" Ox3" CONCRETE SCREWS @ 32"O.C. (STAGGERED) PANEL EDGE NAILING 2x4 STUD WALL INFILL AT (E)GARAGE OPENING WALL SHEATHING, SEE SHEAR SCHEDULE PANEL EDGE NAILING PT 2x4 W/ (2) ROWS OF Y"Ox3" CONCRETE SCREWS @ 12"O.C. I I (E)4" CONC SLAB I I I (E)FTG I I I I F_J L-1 TYPICAL CONCRETE FOOTING AT 2x4 GARAGE INFILL 1 "=1'-0" I lXraloral m TalaIN WALL STUC (2) #4's CONT W/ 24" MIN LAP SPLICE FIRM UNDISTURBED OR COMPACTED SUB -GRADE INTERIOR STRIP FOOTING AT EXISTING SLAB 1 "=1'-0" O 0 a) U w mLucn L/) -0 a) u mC fu cu co m ra Ln m m N O C 7J- z N LJ O N Q N 0 O z (E)4" CONC SLAB (E)4" CONC SLAB Q — I� (E)FTG > > o J L� rn 0 fn � -1Q () Q E U = > o Z u6 06 O m C) z 5 Q ca w O 0 . _ 00 0 Z O Z) TYPICAL INTERIOR FTG 6 FLOOR ASSEMBLY ATTACHMENT O "=1'-0" LL 0 �F WA I �P 5 75�_crti �ss`IONAL E��1 07/05/2024 DESIGNED BY: JTM DATE: 3/7/2024 PROJECT #: 24012 S401 SHEET 7 OF 8 SHEET SIZE: 24" x 36" NEW SISTERED RAFTER - SEE PLAN EXISTING MODIFIED TRUSS SEE PLAN EXISTING ROOF SHEATHING SEE PLAN SIMPSON RBC OR LS70 CLIPS @ 72" O.C., PER SHEAR SCHEDULE AT SHEAR WALLS EDGE NAIL SEE PLAN i i 2x FULL DEPTH VENT AS I - NO OVERHANG AT SIM— EDGE NAILING WALL SHEATHING SEE SHEAR SCHEDULE i SIMPSON H2.5 CLIP EA TRUSS i (E) CONT. DBL TOP PLATES �-2x2 ATTACHED TO (E)2x4 STUDS W/ #80" WOOD SCREWS & 8" \ / O.C. X BEAM/HEADER @ SOME LOCATIONS SEE PLAN RAFTER TO 2x4 FURRED WALL CONNECTION 1 "=1'-0" PANEL EDGE NAIL SEE PLAN PANEL EDGE NAILING E)ROOF SHEATHING I I I I (E)RAFTERS I SIMPSON A35 OR HGA10TK CLIPS @ 72" O.C., PER SHEAR SCHEDULE @ I� SHEAR WALLS (E) SIMPSON H2.5 CLIP EA RAFTER X (E) CONT. DBL TOP PLATES (E)2x6 STUD WALL BEAM/HEADER @ SOME LOCATIONS SEE PLAN INTERIOR SHEAR WALL CONNECTION AT SIM: NEW 2X6 CEILING JOISTS, ATTACH TO RAFTER W/ (3) 10d's (E)ROOF SHEATHING (E)ROOF SHEATHING 1 L----- — ��------- L----- — ��-------- XI � O (E)FLAT 2X4 KI vi (E)FLAT 2X4 XI 0 O uw OUTLOOKERS I I OUTLOOKERS I I m w N @ 24" O.C. I I I @ 24" O.C. I I I Ln-0 I I I I I a) u I I I I I C fu I I II m m co m _ I I (E) PRE-MFR TRUSSES I I �—(E) PRE-MFR TRUSSES Ln m I II I II Nod SIMPSON A35 OR HGA10TK I I I SIMPSON A35 OR HGA10TK CLIPS @ 72" O.C., PER CLIPS @ 72" O.C., PER SHEAR SCHEDULE @ I I SHEAR SCHEDULE @ SHEAR WALLS I I I SHEAR WALLS tLI PANEL EDGE NAILING PANEL EDGE NAILING 2x2 ATTACHED TO (E)2x4 STUDS W/ �i NOT USED \ #8x3" WOOD SCREWS & 8" O.C. \ / I 2x4 STUD WALL BEAM/HEADER @SOME X BEAM/HEADER @SOME X I ATTACH TO BE ABOVE LOCATIONS SEE PLAN / \ LOCATIONS SEE PLAN / \I 2x4 STUD WALL z ATTACH TO BE ABOVE cn IN c� z Q U J ROOF GABLE TO 2x6 FURRED WALL ROOF GABLE TO 2X4 WALL 1 "=1'-0" 1 "=1'-0" U 8d's @ 3" O.C. INTO BLOCKING NEW STUD WALL PER PLAN FULL DEPTH 2x BLOCKING AT EVERY OTHER BAY EXISTING ROOF SHEATHING, SEE PLAN NEW 2X6 CEILING JOISTS SIMPSON LUS26 2x6 #2 D.F. LEDGER W/ (2) ROWS 3-5/8" FASTEN MASTER LEDGERLOKS @ 16" O.0 INTO STUDS NEW RAFTERS TO WALL DETAIL 8d's @ 3" O.C. INTO BLOCKING NEW RAFTER PER PLAN -IN NEW BEAM PER PLAN FULL DEPTH 2x BLOCKING AT EVERY OTHER BAY EXISTING ROOF SHEATHING, SEE PLAN SIMPSON H3 CLIP EA. RAFTER SIMPSON LUS26 'NEW 2X6 CEILING JOISTS 2x6 #2 D.F. LEDGER W/ (2) ROWS 3-5/8" FASTEN MASTER LEDGERLOKS @ 16" O.0 INTO STUDS NEW RAFTERS TO WALL OVER BEAM DETAIL 1 "=1'-0" N LJ o N Q N 0 O z VJ c: O J .U) co > O w O 00 a U) Q E V C 0600 , z 5- J � C'4 Q Z W ^W\, Q LL 00 0 W O ILL ^ca LLO 0 I..L ry P 5375�_crti e:k �SsjONAL E��1 07/05/2024 DESIGNED BY: JTM DATE: 3/7/2024 PROJECT #: 24012 S402 SHEET X OF 8 SHEET SIZE: 24" x 36"