REV1 APPROVED BLD2024-0321+Architectural_Plan+7.5.2024_10.51.21_AM+4359696F-1
A1515KEVIATION5
AB
ANCHOR BOLT
HT
HEIGHT
AGGR
AGGREGATE
HVAC
HEATING, VENTILATION
ALT
ALTERNATE
� AIR CONDITIONING
APPROX
APPROXIMATE
ID
INSIDE DIAMETER
ARCH
ARCHITECTURAL
INSUL
INSULATION
BD
BOARD
INT
INTERIOR
BLDG
BUILDING
JNT
JOINT
BILK
BLOCK
JST
JOIST
BLKG
BLOCKING
LFA
LOAD FROM ABOVE
BM
BEAM
MAX
MAXIMUM
DOT
BOTTOM
MFR
MANUFACTURER
BTWN
BETWEEN
MIN
MINIMUM
CJ
CONTROL JOINT
MISC
MISCELLANEOUS
CLR
CLEAR
MO
MASONRY OPENING
CMU
CONCRETE MASONRY
MTL
METAL
UNIT
NO
NUMBER
COL
COLUMN
NTS
NOT TO SCALE
CONC
CONCRETE
OC
ON CENTER
CONN
CONNECTION
OD
OUTSIDE DIAMETER
CONSTR
CONSTRUCTION
OH
OVERHEAD
CONT
CONTINUOUS
OPG
OPENING
DEG
DEGREE
OPP
OPPOSITE
DET
DETAIL
PCT
PRE -CAST
DTL
DETAIL
PL
PROPERTY LINE
DIAG
DIAGONAL
PLYWD
PLYWOOD
DIA
DIAMETER
PLY
PLYWOOD
0
DIAMETER
KID
ROOF DRAIN
DN
DOWN
RE:
REFER TO ...
DWG
DRAWING
REINF
REINFORCED
(E)
EXISTING
READ
REQUIRED
EA
EACH
KM
ROOM
EJ
EXPANSION JOINT
RO
ROUGH OPENING
EIFS
EXTERIOR INSULATION
SCHED
SCHEDULE
* FINISH SYSTEM
SECT
SECTION
EL
ELEVATION
SF
SQUARE FOOT
ELEV
ELEVATION
SHT
SHEET
EQUIP
EQUIPMENT
SIM
SIMILAR
EW
EACH WAY
SPEC
SPECIFICATION
EXF
EXPANSION
SQ
SQUARE
EXT
EXTERIOR
SS
STAINLESS STEEL
FD
FLOOR DRAIN
STAGG
STAGGERED
FDN
FOUNDATION
STD
STANDARD
FF
FINISH FLOOR
STIFF
STIFFENER
FIN
FINISH
STL
STEEL
FLR
FLOOR
STRUC
STRUCTURAL
FND
FOUNDATION
TR
TREAD
FOB
FACE OF BRICK
TSB
TOP * BOTTOM
FOC
FACE OF CONCRETE
TAG
TONGUE * GROOVE
FS
FULL SIZE
THK
THICK
FT
FOOT OR FEET
T/
TOP OF
FTG
FOOTING
TYP
TYPICAL
FUPIP,
FURRING
LINO
UNLESS NOTED
GA
GAUGE
OTHERWISE
GALV
GALVANIZED
VER
VERIFY
GR
GRADE
VERT
VERTICAL
GYP
GYPSUM
W/
WITH
GYP BD
GYPSUM BOARD
W/O
WITHOUT
GWB
GYPSUM WALL BOARD
(L
CENTERLINE
PLATE
Parcel Garage Conversion
8918 218th St SW, Edmonds, WA 98026
DI50RIMER: THESE GENERAL NOTES ARE NOT NECESSARILY PROJECT
SPECIFIC, AND SOME NOTES MAY NOT APPLY TO EACH PROJECT.
ALL WORK IS TO COMPLY WITH THE LATEST ADOPTED VERSION OF THE
INTERNATIONAL RESIDENTIAL CODE (IRC) AND/OR ANY APPLICABLE COUNTY OR
LOCAL JURISDICTION. (IBC, IMC, WSEC, UPC)
THE CONTRACTOR IS RESPONSIBLE TO CHECK THE PLANS AND IS TO NOTIFY
THE DESIGNER OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF
CONSTRUCTION. OWNER/CONTRACTOK SHALL VERIFY WITH LOCAL BLDG. DEFT
WHICH CLIMATE ZONE THE PROJECT WILL BE BUILT IN.
WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
DO NOT SCALE THE DRAWINGS.
THIS PLAN IS DESIGNED TO MEET THE CURRENTLY ADOPTED WASHINGTON
STATE ENERGY CODE (2018).
INFILTRATION: THE SEALING METHODS BETWEEN DISSIMILAR MATERIALS SHALL
ALLOW FOR DIFFERENTIAL EXPANSION AND CONTRACTION. THE FOLLOWING
SHALL BE CAULKED, GASKETED, WEATHERSTKIFPED, OR OTHERWISE SEALED
WITH AN AIR BARRIER MATERIAL, SUITABLE FILM, OR SOLID MATERIAL.
• ALL JOINTS, SEAMS, AND PENETRATIONS
• SITE BUILT WINDOWS, DOORS, AND SKYLIGHTS
• OPENINGS BETWEEN WINDOW AND DOOR ASSEMBLIES AND THEIR
RESPECTIVE JAMBS AND FRAMING
• UTILITY PENETRATIONS
• DROPPED CEILINGS OR CHASES ADJACENT TO THE THERMAL ENVELOPE
• KNEE WALLS
• WALLS AND CEILINGS SEPARATING THE GARAGE FROM CONDITIONED SPACES
• BEHIND TUBS AND SHOWERS ON EXTERIOR WALLS
• COMMON WALLS BETWEEN DWELLING UNITS
• OTHER SOURCES OF INFILTRATION
GLAZING f- EGRESS:
DOOR/WINDOW TAG:
5GG8 = WIDTH FEET/INCHES X OPENING HEIGHT FEET/INCHES
EXAMPLE: 5GG8 IS 5'-G" WIDE x 0-8" TALL
BASEMENTS AND EVERY SLEEPING ROOM TO HAVE MIN. WINDOW OPENING OF
5.7 SQ. FT. WITH A MIN. WIDTH OF 20" AND A SILL HEIGHT NOT MORE THAN
44" ABOVE FIN. FLR.
WINDOWS SHALL HAVE TEMPERED GLAZING IF ANY SINGLE PANE OF GLASS
LARGER THAN 9 SQUARE FEET, IF WITHIN 24" OF ANY DOOR (REGARDLESS OF
WALL PLANE), IF THE BOTTOM EDGE IS LESS THAN 1 8" ABOVE THE FINISHED
FLOOR FLOOR OR WALKING, OR IS LOCATED WITHIN 3G" FROM A WALKING
SURFACE.
ALL EXTERIOR WINDOWS ARE TO BE DOUBLE GLAZED AND ALL EXTERIOR
DOORS ARE TO BE SOLID CORE WEATHERSTRIPPING. PROVIDE 1/2" DEAD BOLT
LOCKS ON ALL EXTERIOR DOORS AND LOCKING DEVICES ON ALL DOORS AND
WINDOWS WITHIN 10' (VERTICAL) OF GRADE. PROVIDE PEEPHOLE 54-GG"
ABOVE FIN. FLR. ON EXTERIOR ENTRY DOORS.
GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS,
STEAM ROOMS, BATHTUBS, * SHOWERS, AND IN ANY PART OF A BUILDING
WALL ENCLOSING THESE COMPARTMENTS, WHERE BOTTOM EDGE OF GLAZING
IS LESS THAN GO" MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING
SURFACE, TO BE TEMPERED GLAZING.
ALARMS t ELECTRICAL:
SMOKE DETECTORS SHALL BE INSTALLED IN EA. SLEEPING ROOM, OUTSIDE
THE IMMEDIATE VICINITY OF EACH SLEEPING AREA, AND ON EACH STORY OF
THE DWELLING. ALL DETECTORS SHALL BE HARDWIRED INTO BUILDING POWER
SUPPLY W/BATTERY BACKUP AND BE INTERCONNECTED SUCH THAT THE
ACTUATION OF ONE ALARM WILL ACTUATE ALL THE ALARMS AND WILL BE
AUDIBLE IN ALL SLEEPING AREAS OVER BACKGROUND NOISE LEVELS WITH ALL
INTERVENING DOORS CLOSED.
ELECTRICAL RECEPTACLES IN BATHROOMS, KITCHENS, EXTERIOR LOCATIONS,
ALL EXPOSED INSULATION IS TO HAVE A FLAME SPREAD RATING NOT TO AND GARAGES SHALL BE G.F.I. OR G.F.I.C. PER NATIONAL ELECTRICAL CODE
EXCEED 25. A SMOKE -DEVELOPED INDEX NOT TO EXCEED 450, WHEN TESTED (N.E.C.) REQUIREMENTS.
IN ACCORDANCE WITH ASTM E 64, AND CRITICAL RADIANT FLUX NOT LESS
THAN 0. 12 WATTS PER SQUARE CENTIMETER. WHOLE HOUSE VENTILATION TO BE MET PER IRC SECTION M 1 505.4.3 * IRC
TABLE M 1 505.4.3(I ): DWELLING AREA < 1 ,500; BEDROOMS 0- 1; RATE
INSULATE ALL ACCESS DOORS/HATCHES TO CRAWLSPACES AND ATTICS TO THE REQUIREMENT 30 CFM.
EQUIVALENT RATING OF THE WALL, FLOOR, OR CEILING THROUGH WHICH THEY
PENETRATE. VENTILATION NOTES:
ROOF (VAULTED CEILING)
R-38
ROOF (FLAT CEILING)
R-49
EXTERIOR WALLS
R-2 1
INSULATION
UNDERFLOOR INSULATION
R-30
WALLS BELOW GRADE (INTERIOR)
K-2 1
WALLS BELOW GRADE (EXTERIOR)
R-1 0
SLAB EDGES @ HEATED AREAS
R-1 0
AIR DUCT (AT UNHEATED AREA)
R-8
MAXIMUM GLAZING AREA
NO LIMIT
GLAZING U-FACTOR (VERTICAL)
U=0.30
GLAZING U-FACTOR (OVERHEAD)
U=0.50
LAZING/
DOORS/ELEC
DOOR U-FACTOR
(DOORS W/MORE THAN 50% GLAZING
SHALL BE CONSIDERED A WINDOW)
U=0.20
FURNACE PERFORMANCE
60% EFF.
RECESSED LIGHTING FIXTURES
IC RATED
3.4
DUCTLESS SPLIT SYSTEM, ZONAL
0.5
CONTROL. MIN HSPF OF 10
CREDITS
4
ELECTRIC RESISTANCE WITH DUCTLESS
1.5
HEAT PUMP
CREDITS
TOTAL CREDITS:
2.0 CREDITS
PROVIDE POSITIVE VENTILATION AT EACH END OF RAFTER SPACE AT VAULTED
CEILING AREAS, AND INSULATION BAFFLES AT SAVE VENTS BETWEEN RAFTERS.
RAFTER VENTILATION IS ALSO REQUIRED AT BLOCKING LOCATIONS ABOVE THE
PLATE.
PROVIDE I SQ. FT. OF ROOF VENTILATION FOR EVERY 150 SQ. FT. OF LIVING
AREA.
PROVIDE I SQ. FT. OF CRAWL SPACE VENTILATION FOR EVERY 150 SQ. FT. OF
LIVING AREA.
JOISTS * TRUSSES:
ROOF AND FLOOR JOIST LOCATIONS ARE SCHEMATICALLY SHOWN ON THE
PLANS. IT IS NOT THE INTENT OF THE STRUCTURAL PLANS TO GRAPHICALLY
LOCATE ALL FRAMING MEMBERS. THE CONTRACTOR IS RESPONSIBLE FOR
SPACING FRAMING MEMBERS AS NOTED ON THE PLANS AND GENERATING
MEMBER LAYOUT FOR SHOP DRAWINGS AND QUANTITY TAKEOFFS.
THE TRUSS AND JOIST MANUFACTURER SHALL VERIFY BEARING COMPATIBILITY
(CRUSHING) WITH THE PLATE MATERIAL. TYPICALLY, COMPOSITE BEAMS SHALL
BE FULLY BEARING ON 2x_ WALLS. I.E. BREAK RIM OR BLOCKING TO ALLOW
FULL BEARING OVER PLATES.
SHEATHING:
DIRECTION OF ALL OSB SHEETS PERPENDICULAR TO JOIST DIRECTION.
EXPOSED FRAMING SHALL BE PRESSURE TREATED (PT) VERTICAL
HORIZONTAL FRAMING AT WATERPROOFED WALKWAYS AND PRIVATE DECKS.
ALL EXPOSED BEAM HANGERS SHALL BE POST HOT -DIPPED GALVANIZED AND
HAVE CONCEALED FLANGES.
PROVIDE WALL BLOCKING FOR ALL WALL MOUNTED EQUIPMENT (SUCH AS
TOWEL BARS, GRAB BARS, TOILET PAPER HOLDERS, DOOR STOPS, ETC.)
ALL CONNECTORS ARE TO BE 51MF50N STRONG TIE PRODUCTS , UNLESS
NOTED OTHERWISE.
HANDGRIP SECTION NOTES:
TYPE I - CIRCULAR
OUTSIDE DIAMETER BETWEEN 1 1/4" AND 2"
TYPE I - NON -CIRCULAR
PERIMETER DIMENSION BETWEEN 4" AND G 1/4"
CROSS SECTION DIMENSION MAX. 2 1/4"
EDGES SHALL HAVE RADIUS MIN. 0.0 1 "
TYPE 2 - PERIMETER GREATER THAN G 1/4"
GRASPABLE FINGER RECESS AREA BOTH SIDES OF PROFILE
TO BEGIN WIN 3/4" MEASURED VERTICALLY FROM THE TALLEST PART OF THE
PROFILE
TO ACHIEVE A DEPTH MIN. 5/ 1 G" WIN 7/8" BELOW THE WIDEST PART OF THE
PROFILE
TO CONTINUE MIN. 3/8" TO A LEVEL MIN. 1 3/4" BELOW THE TALLEST PART OF
THE PROFILE
WIDTH OF THE HANDRAIL ABOVE THE RECESS BETWEEN 1 1/4" AND 2 3/4"
EDGES SHALL HAVE RADIUS MIN. 0.01"
SYMBOL LEGEND
X BUILDING DETAIL #
# SECTION SHEET #
REFERENCE
# DETAIL DETAIL #
# REFERENCE SHEET #
SHEET INDEX
5HEET
5HEET CONTENTS
C5
COVER SHEET
AO.0
ENERGY CALCULATIONS
AO. I
51TE PLAN
A I .0
A5-13UILT BUILDING ELEVATIONS
A I . I
PROP05ED BUILDING ELEVATIONS
A2.0
A5-BU I LT FLOOR PLAN
A2. I
PROPOSED FLOOR PLAN
A3.0
OVERALL ROOF PLAN
A3. I
DETAILS * SCHEDULES
51 . 1
STRUCTURAL NOTES
51.2
TYPICAL NOTES if DETAILS
51.3
TYPICAL NOTES * DETAILS
52.1
FOUNDATION PLAN
52.2
ROOF FRAMING PLAN
53.1
FIRST LEVEL SHEAR PLAN
54.1
FOUNDATION DETAILS
54.2
ROOF FRAMING DETAILS
TOTAL NUMBER OF SHEETS
17
PROJECT LOCATION
Z 0
Q> Bell St a
4
60� -IiAaln.St
� aple way s
= Maple St w 'Yost Park
N Alder St
I I
,nut St Walnut St �'/�a/7
Cedar St a
v
e St Spruce St
PO
�,3ggdl�
NI 214th PI SW ry u wtlotn way
iSt� I 3 2150St SW
Pine St t 216th St SW 216th St SW
217th St SW c 217t St SW:E l l
3 �
't g Dropped pin
L �
I Place Middle
g j SO-1
g I 208th St SW
g I
S
< 210th St
< g i
� r
-—F-2,2thstsw—
Edmonds Woodwayl If
High School I
215th St SW
D
216th St SW f
Swedish 216th St
Medical
Cemer
Edmonds
218th St SW
I
/
—
=22ahStsW----
--� _
—-zxanstsw-; — --
Westgate
I
`p
Elementary
Scholl
7
�0
I
D o
,o
222nd St SW
222nd St SW I
Birch St
-Z
w
> a
se
w
�
>
=224th 1
a 224th St SW v
224th St rn
224th Stl SW
St SW
N
r
N>
�C
w
D
>
>
a
'Sth St SW
I
F
D
226th St SW
Fmm�,vxll
°�
Esperalnce
s}S PIS`N '
9=2MthStSWa —, �2 hStSW--- .StSw— 22M
�I a
/ OLYMPIC
HILLS
DRAFTING C�
DESIGN, LLC
Olympic Hills
Drafting &
Design, LLC
Seattle, NA
301.255.1841
N
w o
N
to
w
01- ,4
O
VICINITY
MAP
nnL
�lJ
-�'
>
O
M
PROJECT INFORMATION
�
p
�
`�
�
CLIENT:
Tylee * James Pardi
U
s
Q
CONTACT:
tayleerobin5on@gmail.com
51TE
89 18 2 18th St 5W
ADDRE55:
Edmonds, WA 98026
CV
O
0
PARCEL #:
(�
U
QD
m
E
FLOOR AREAS:
_
CO
-
1 5t FLOOR:
(E)20G7 5Q FT, (N) 246G 5Q FT
—�
LLJ
GARAGE:
(E)718 5Q FT, (N) 299 5Q 5T
L
TOTAL:
2785 5Q FT (NO CHANGE TO BUILDING FOOTPRINT)
D_
LOT SIZE: 13,OG8 5Q FT
ZONING:
R5-8
MIN LOT AREA
8,000 5Q FT
UNITS PER ACRE
5.5
MIN. LOT WIDTH
70 FT
STREET 5ET13ACK
25 FT
SIDE SETBACK
7.5 FT
REAR SETBACK
15 FT
MAX. HEIGHT
25 FT
MAX. LOT
35%
COVERAGE
Proiect Description:
The project 15 an existing 1-story residence. Addition con5i5t5 of using 4 19 5c(
ft of an existing 7 1 8 5,5[ ft of the attached two car garage into livable space. The
the remaining space will be utilized for one -car garage.
DISCLAIMER:
CONTRACTOR IS TO VERIFY ALL SITE CONDITIONS AND ADAPT DESIGN PLANS AS
NECESSARY. ANY RESPONSIBILITY OF OLYMPIC HILLS DRAFTING * DESIGN, LLC FOR ANY
DAMAGES RELATING TO THE ACCURACY AND INTEGRITY OF THESE PLANS SHALL BE
LIMITED TO THE AMOUNT OF FEE CHARGED. IF ANY DISCREPANCY BETWEEN THESE PLANS
AND THE SITE CONDITIONS DIFFERS, IT IS RECOMMENDED THAT WORK BE STOPPED AND
THE DESIGNER BE CONSULTED.
THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION
OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR
TO CONSTRUCTION BY CALLING THE UNDERGROUND LOCATE LINE AT 1 -800-424-5555 A
MINIMUM OF 48 HRS. PRIOR TO ANY EXCAVATION.
CALL BEFOKE YOU DIG
(600) 424-5555
Drawn: NAB
Designed: NAB
Scale: AS SHOWN
Date: 7/5/2024
Job Number:
24-006
Sheet Number:
CS
1 of 9
F-1
8918 218TH ST SW, EDMONDS, WA 98026
(E) WATER METER
(E) SEPTIC
422 \
(E) DS TO (E)
TIGHTLINE
(E) ROCKERY
TO REMAIN
GRADE VARIES
(E) DS TO (E)
TIGHTLINE c,
u7
(E) CONCRETE PATIO —
133 SF
424' 426'
218TH ST SW
-- 78' ----- —
,� 428'
LO a
° (E) CONCRETE PATIO &
WALKWAYS
789 SF
E DS TO E TIGHTLINE
(E)RESIDENCE w w
2067 SF
� (N) DDITI N �
SE
b (E) TTAC ED A
2 o9 SQ FT
11.0 .:
M
In
°
422' 424' 426'428'430'
SITE PLAN
0
a
PARCEL NO: 00380300100500 A
(N)ADDITION TO CONVERT
� EXISTING GARAGE
�— (E)COVERED PORCH
48 SF
GRAVEL PATHWAY &WALKWAY
� 227 SF
� (E) DS TO (E) TIGHTLINE
I 430'
(RASH CAN ENCLOSURE
� 64 SF
(E) DS TO (E) TIGHTLINE
� (E) CONCRETE PATIO
� 36 SF
(E) STONE PAVERS
432'
V(E)PROPERTY LINE FENCE
I
I
I
I
PROPERTY DESCRIPTION
SECTION 30 TOWNSHIP 27 RANGE 04 QUARTER NW
AURORA HEIGHTS DIVISION #3
SP 260(8-81)
DRAINAGE
PLANS UNCHANGED FROM EXISTING CONDITION
(E) DS TO TIGHTLINE SYSTEM
CALL BEFORE YOU DIG
(800) 424-5555
SITE PLAN DISCLAIMER:
DO NOT SCALE.
SITE CONTOUR INFO PROVIDED BY CITY OF
EDMONDS.
NOT INTENDED TO BE USED IN PLACE OF A
SURVEY.
THIS PLAN WAS CREATED FROM SATELLITE
IMAGERY AND IS TO BE USED FOR
REPRESENTATION ONLY.
ALL CONTOURS AND BUILDINGS SHOWN ARE
REPRESENTATIVE ONLY AND NO
STRUCTURES OR PAVED AREAS SHALL BE
CONSTRUCTED BASED SOLELY ON THIS PLAN.
CONTRACTOR TO VERIFY ALL DIMENSIONS
ON SITE.
/ OLYMPIC
HILLS
DRAFTING
DESIGN LLC
Olympic Hills
Drafting &
Design, LLC
Seattle, NA
301.255.1841
N
LU
CD
LO
ti
(10
z
0
w
z
�
w
a
>
U)
W
w
0
O
L
(S)
6�
Q
-�
CV75
a�
CO
w
75
D—
PROJECT INFORMATION
EXISTING COVERAGE:
EXISTING RESIDENCE FOOTPRINT: 2067
EXISTING ATTACHED GARAGE: 718
EXISTING COVERED PATIO: 48
EXISTING CONCRETE PATIO: 169
EXISTING DRIVEWAY & WALKWAY: 789
EXISTING GRAVEL WALKWAY: 227
TRASHCAN ENCLOSURE: 64
TOTAL EXISTING: 4082
Drawn: NAB
Designed: NAB
Scale: AS SHOWN
Date: 7/5/2024
PROPOSED NEW COVERAGE:
ADDITION: 419
EXISTING ATTACHED GARAGE: —419
TOTAL NEW: 0
LOT AREA: 0.3 ACRE OR 13068 SF
TOTAL IMPERVIOUS AREA: 4082 SO FT (32.2%
1" = 15' ON 24x36 1" = 30' ON 11x17 1
Job Number:
24-006
Sheet Number:
A0.1
3 of 9
F-1
/ OLYMPIC
HILLS
DRAFTING
DESIGN, LLC
Olympic Hills
Drafting &
Design, LLC
Seattle, NA
301.255.1841
N
W O
N
LO
FASCIA W/
LINE GUTTER z
0
TOP Of GARAGE WALL = MATCH (E)LU
z �
0 w
LAP SIDING
> U)
� a
w
Q I- �
CORNER TRIM
<=LOOP, = 0'-0"
EA5T A5—BUILT ELEVATION
31b"=11-011
O_ O
> (�
O
c6
SLOPE TO BE VERI PI ED
LL O ct�
�
�
EXISTING DECORATIVE VENT
N EI ELD (E) ASPHALT ROOEI NG
U
Q
U
(E)CH I M N EY TO DE REMOVED
N
CD C6
75
p
—N 6�
E
4: 12
(E) FASCIA W/
_I 2 12_
3 3
Q—
K—LINE GUTTER
_I 2
Q
TOP OF GARAGE WALL = MATC
(E) LAP
(E) P.1
(E) CORI\
FLOOR = C.
SOUTH A5—BUILT ELEVATION
3/6"=1 '-0"
AS -BUILT NOTES
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING
AND TEMPORARY BEARING WALL PLACEMENT AND
CONSTRUCTION.
CONTRACTOR IS TO VERIFY DIMENSIONS OF ALL
REMOVED WALLS AND SLABS IN THE FIELD.
ALL EXISTING INTERIOR WALLS ARE OBSERVED TO
BE 2x4 CONSTRUCTION.
ALL EXISTING EXTERIOR WALLS ARE OBSERVED TO
BE 2x4 CONSTRUCTION.
Drawn: NAB
Designed: NAB
Scale: AS SHOWN
Date: 7/5/2024
Job Number:
24-006
Sheet Number:
A1.0
4 of 9
F-1
(E) FASCIA W/
K-LINE GUTTER
TOP Of GARAGE WALL = MATC
(E) LAP
(E) P.I
(E) CORf
FLOOR = C. ..
;TOR,
► FASCIA W/
LINE GUTTER
TOP Of GARAGE WALL = MATCH (E)
A/I N DOW H DR = G'-8"
'--ADJU5T A5 NEEDED FOR]
=NING TRIM, MATCH STRUCTURAL HDR
OR PROVIDE 5/4x4
M
/ OLYMPIC
HILLS
DRAFTING
DESIGN, LLC
Olympic Hills
Drafting &
Design, LLC
Seattle, NA
301.255.1841
CORNER TRIM z
0
LAP 51DINGLn
w
W
FLOOR = O'-O"
z �
PA5T PROP05ED ELEVATION
SOUTH PROP05ED ELEVATION
3/8"=1 '-0"
w
Q I- �
ELEVATION
ALL EFFORT TO INSURE THE ACCURACY OF THESE
NOTES
PROVIDE CONTINUOUS GUTTERS AND
DRAWINGS HAS BEEN TAKEN. HOWEVER,
DOWNSPOUTS AT ALL EAVES TYPICAL. LOCATE PER
CONTRACTOR IS TO VERIFY ALL NOTES, MATERIALS,
OWNER OR CIVIL.
DIMENSIONS AND CONDITIONS IN THE FIELD.
AS -BUILT NOTES
PLUMBING AND VENTILATION PENETRATIONS ARE
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING
NOT SHOWN AND ARE TO BE LOCATED BY THE
AND TEMPORARY BEARING WALL PLACEMENT AND
AND TEMPORARY BEARING WALL PLACEMENT AND
CONTRACTOR AND TO CONFORM TO IRC SECTION
O
CONSTRUCTION.
CONSTRUCTION.
P3102.
—
O
CONTRACTOR IS TO VERIFY DIMENSIONS OF ALL
ALL EXTERIOR JOINTS AND PENETRATIONS ARE TO
ALL LIGHT BLOCKS ON FACADE ARE TO BE FURRED
C6
REMOVED WALLS AND SLABS IN THE FIELD.
BE CAULKED.
OUR AN ADDITION I" FROM SIDING.
nn>
ALL EXISTING INTERIOR WALLS ARE OBSERVED TO
PROVIDE SHEET METAL FLASHING AND
GUTTERS ARE TO LAP UNDER DRIP EDGE AT GABLE
>�
0
BE 2x4 CONSTRUCTION.
COUNTERFLASHING AT ALL ROOF PENETRATIONS,
ENDS.
co
CHIMNEYS, AND SKYLIGHTS.
ALL EXISTING EXTERIOR WALLS AKE OBSERVEDn TO
ALL TRIM WORK IS TO BE INSTALLED PRIOR TO
' \
n
BE 2x4 CONSTRUCTION.
EXTERIOR BUILDING WRAP TO BE CONTINUOUS
SIDING MATERIALS. BUTT SIDING TO TRIM WORK
v
S
Q
E
WHERE POSSIBLE. LAP ALL HORIZONTAL SEAMS G"
AND CAULK.
n \
�_
MIN AND ALL VERTICAL SEAMS G"- 1 2" TAPE ALL
BUILDING WRAP SEAMS AND TAPE BUILDING WRAP
OLYMPIC HILLS DRAFTING * DESIGN TAKES NO
N
TO FOUNDATION BELOW SILL PLATE.
RESPONSIBILITY FOR WATER INTRUSION
�,(�
�
75
PROTECTION. CONTRACTOR IS TO PROVIDE
HOLD ALL SIDING MATERIAL I" OFF OF ROOF AND
ADEQUATE FLASHING, CAULKING, AND SEALING.
Q
8" MIN OFF OF FINISHED GRADE.
7)
E
CO
-�—�
O
�
GARAGE HEADER HEIGHT
TO MATCH EXISTING, HDR
0
n--
SIZE PER STRUCTURAL
(L
Drawn: NAB
Designed: NAB
Scale: AS SHOWN
Date: 7/5/2024
Job Number:
24-006
Sheet Number:
AL I
5 of 9
F-1
c
I
29'-8 5/ 1 G"
N
2362 23G2 2362 2362 2362 23G2 23G2
2362 23G2 2362
2362
2362
N
�
N
O
\
Ln
L
—_
SOLARIUM
291- 1 " X 91-8"
Ln
29G2
31OG2
31OG2 31OG2
29G2
w
v
31125
31125
0
1859
47GO 8OG8
G730
G730
C9
-_
— — —
— —
— — — — — — — — — — — — — — —
— — — — — — — — — — — — — — — — ® — —
— — — — — — — —
— — —
— — —
—
—
Qq
Ln—
BEDROOMLn
_
O
1 5'-5" X 91- 1 0"
O
N
N
O
�
5D
2GG8
N
"'
LIVING
N
37'-5" X 22'-G"
I
I
p
C\j
HAI I
WAY
®
o
8'-0" X
1 7'-3"
00 BATHROOM
GO 5D
U 91-2" X 71-8"
N
D
U
F
LL
o -
MATER BATHROOM
9'-2" X9'-2"
30G8 21015
O
mo
X
co
I I
p
m
IN
INFILL (E) DOOR TO GARAGE—"'
ARAGE
2GG8
2GG8
5D
EP
HD Fir-
I
(E) CHIMNEY TO BE REMOVED
BY OWNER
MASTER
BEDROOM
o
m
IA—
17'-8"
X 1 1 '-3"
No
N
N
L
LU
J
N
GARAGE
D
27'-3" X 25'-8"
C�
2GG8
WAI K-I N-0
OSET
51 12G
LD
—
9'-4"
X 3'-5"
o I
N
N
WINDOW TO BE REMOVED
I
I
N
m
C?
I
I
m
Ln
I GARAGE DOOR TO BE REMOVED — —
18070
—
— I
12'-3 I /4"
10,
28'-G 7/8"
10,
57-9 7/8"
AS -BUILT FLOOR PLAN
1 /4"=1 '-0"
AS -BUILT NOTES
CONTRACTOR 15 RESPONSIBLE FOR ALL SHORING
AND TEMPORARY BEARING WALL PLACEMENT AND
CONSTRUCTION.
CONTRACTOR 15 TO VERIFY DIMENSIONS OF ALL
REMOVED WALLS AND SLABS IN THE FIELD.
ALL EX15TING INTERIOR WALLS ARE OBSERVED TO
BE 2x4 CONSTRUCTION.
ALL EX15TING EXTERIOR WALLS ARE OB5ERVED TO
BE 2x4 CONSTRUCTION.
/ OLYMPIC
HILLS
DRAFTING c�
DESIGN, LLC
Olympic Hills
Drafting &
Design, LLC
Seattle, NA
301.255.1841
N
W O
N
LO
w
01- —1
O
LL—
O
O
(S)
LL-QjC(:)CD
��
73
V
G)
E
/I^
U1
—
o
QLLJ
r(��
�V
D—
Drawn: NAB
Designed: NAB
Scale: AS SHOWN
Date: 7/5/2024
Job Number:
24-006
Sheet Number:
A2.0
6 of 9
F-1
L
29'-8 5/ 1 G"
23G2
N
2362 2362 2362 2362
2362 2362
IF
2362 2362 2362 2362 2362
N
c
N
O
\
It
Ln
—_
SOLARIUM
29'- 1 " X 9'-8"
Ln
29G2
31OG2
31OG2 31OG2
2962
Uj
31125
31125
1859 L
47GO 8OG8
C
G730 G730
-----
4'-5 /4"
8'-7" 5'-G 3/4"
_
Ln
---
-- —�I
I I
Ln-----------------------
,�
BEDROOM
w
_
1 5'-4" X 1 O'A'
N
❑®
III
III
TT
III
5D
I I
III
�
2GG8
=__��----�r==--
_
II
III
II II
II
N
LIVING
1f
II u
=
N
I I
II
37-5" X 22'-6"
HALLWAY
o
8'-0" X►
7'-3"
00 BATHROOM
I
I
co
I I
III
III
G0 5D
9'-2" X 7'-8"
N
II
D
II
27-2 3/8"
III
III
FF==-IF==========17-7
wHLn
_
I I
2 -1 "
3'-9 3/4"
8'-0 1 5/ 1 G" 5-2 1 1 / 1 G"
I
II
II
II
Ln
1' 0 7/8"
I
I
�mr
L—
—
— — — — — — --
28G8
_ 5'-0" X 8 -0"
�
MATER BATHROOM
9'-2"X9'-2"
oo
U
30G8 21015
II
N
=
2020 N LU 0 NLn
I
INFILL 2x4
STUD WALL
=
-'
®
w0
EDP,
10'-0"X 10'-7"
_ ---
Ln
I I 2GG8
=--==JL=�
2GG8X=
EP —I
- CEO
—v wt
2060
_
1 17
o
II
—
INSULATED STEEL
SELF -CLOSING
I II
7' 3'-1 "
3'-G 1 /4"
N
co
GARAGE WARM WALLS TO BE
I I I
MASTER
17'-8"
BEDROOM
X I
co
GOG8 O
rH0=
2xG STUD WALL W/ K-2 I FACED
1 III
La!o
N U
GATT INSULATION OR LATEX
N
_
N
N
PAINT WITH 5/6" TYPE-X GWB,
=
CLOSET
FIRE TAPED, MIN.
I I J
U-jj I
<9
2020 N
N
N
CLOSET -1
Go
(� OF BEARING STUD WALL TO ALIGN
WITH � ROOF PEAK ABOVE, SEE
GOG8 �
U
N
5D
O
TRUCT FOR BEARING WALL
L
r �
//x�
2GG8
-T
---=a
— — —
N
I
51 1 2 G
�p
WALK-IN-0 N-0
OSET
—
'- " '- " N 5D
2GG8
CEILING TO HAVE
1 I9'-4"
X 3'-5"
Ln
CLOSET F—
5/8" TYPE-X GWB,
I I
I I
6?
co
N
N
I
FIRE -TAPED MIN I
b� 7 L
— —
— — — —
20G0
O
30x22 ATTIC ACCESS ABOVE LOCATE
I I
-
PER OWNER/CONTRACTOR
Ln
�,
I
I I Q0
Ln
(N) 3- 1 /2" FLUSH BEAM
PER STRUCTURAL
EG
EI vation
I
10070
—
II
7-9 1 /4"
1 3'-9 1 /4"
14'-0 5/8"
10'-5 1 /2"
27-9 7/8"
10'-3 1 /2"
57-9 7/8"
L-2xG STUDS ATTACHED TO
(E)2x4 STUDS @ I G" O.C. LIVING AREA
W/ K-2 1 FACED BATT 24G9 SQ FT
INSULATION OR LATEX PAINT
PROP05ED FLOOR PLAN
17
/ OLYMPIC
HILLS
DRAFTING c�
DESIGN, LLC
Olympic Hills
Drafting &
Design, LLC
Seattle, NA
301.255.1841
® - NEW WALL
- EXISTING WALL o - - - LU N
SD - SMOKE ALARM PER (PC R3 14 p ti
CO - CARBON MONOXIDE ALARM PER IRC R,315
Hp - HEAT DETECTOR ALARM PER IRC R3 14
- EXHAUST FAN PER IRC TABLE M 1 505.4.4
Ul)
KITCHEN: 100 CFM INTERMITTENT OR 25
O
CFM CONTINUOUS
c~i�
BATH: 50 CFM INTERMITTENT OR 20 CFM
>
CONTINUOUS
LU
W.H.F.: 125 CFM WHOLE HOUSE FAN ON 50%
RUN TIMER
z
z
LU
ALL EFFORT TO INSURE THE ACCURACY OF THESE
O
DRAWINGS HAS BEEN TAKEN. HOWEVER, CONTRACTOR IS
>
U)
TO VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD.
�
a
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING AND >
TEMPORARY BEARING WALL PLACEMENT AND
—EXISTING HEAT PUMP CONSTRUCTION.
WITH HSPF > 10.0
WALL HEIGHT = MATCH EXISTING
ALL NEW WALLS ARE TO BE 2xG STUDS @ I G" O.C. AT
EXTERIOR AND 2x4 STUDS @ I G" O.C. AT INTERIOR.
UNLESS NOTED OTHERWISE BY STRUCTURAL.
ALL WINDOW AND DOOR HEADERS ARE TO BE BY
STRUCTURAL.
All EXTERIOR HEADERS MUST BE 4x SIZES UNI FSS
O
L
(4)
SPECIFIED BY STRUCTURAL.
>
cn
0
ALL WINDOWS WITHIN 1 8" OF FLOOR AND 1 2" OF ANY
DOOR ARE TO HAVE TEMPERED
OO
-N
GLASS.
O
ALL SHOWER AND BATHTUB ENCLOSURES ARE TO BE
U
s
Q
GLAZED W/ SAFETY GLASS.
�1.!
PROVIDE COMBUSTION AIR VENTS W/ SCREENS AND
75
DAMPER FOR FIREPLACES, WOOD STOVES, AND ANY75
APPLIANCE W/ ANY OPEN FLAME.
ALL COMBUSTION APPLIANCES WILL BE VENTED DIRECTLY
r �
V
-7
TO THE EXTERIOR. FURNACE FIREBOX AND TANKLE55 WATER
M
HEATERS SHALL HAVE OUTSIDE COMBUSTION AND ARE
O
W
SUPPLY PURSUANT TO REGIONAL AND LOCAL CODES.
L
EXHAUST ALL VENTS AND FANS DIRECTLY TO OUTSIDE VIA
METAL DUCTS.
D—
ELECTRICAL RECEPTACLES IN BATHROOMS, KITCHENS, AND
GARAGES SHALL BE G.F.I. OR G.F.C.I. PER NATIONAL
ELECTRICAL CODE REQUIREMENTS.
ALL EXTERIOR WALL INTERIOR DRYWALL JOINTS ARE TO BE
MUD AND TAPED AND TO HAVE A CLASS I OK I I VAPOR
BARRIER. ALL DRYWALL EDGES AT WALL BOTTOM AND WALL
TOP ARE TO BE CAULKED BEFORE FINISHING.
Drawn: NAB
ALL ELECTRICAL BOXES ARE TO BE AIR TIGHT 9R TO HAVE
CAULKED/FOAMED WIRE PENETRATIONS AND GASKETED Designed: NAB
COVER PLATES.
ALL LIGHT FIXTURES ARE TO BE RATED ICAT. Scale: AS SHOWN
ALL DRYWALL PENETRATIONS ARE TO BE CAULKED OR Date: 7/5/2024
SPRAY FOAMED CLOSED.
ALL FRAMING MATERIAL THAT IS IN CONTACT WITH
CONCRETE IS TO BE PRESSURE TREATED.
FOR OPENINGS NOT DIMENSIONED, ASSUME 4" RETURN TO
JAMB -SIDE OR CL OF DOOR IS AT CL OF SPACE.
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING
AND TEMPORARY BEARING WALL PLACEMENT AND
CONSTRUCTION.
CONTRACTOR IS TO VERIFY DIMENSIONS OF ALL
REMOVED WALLS AND SLABS IN THE FIELD.
ALL EXISTING INTERIOR WALLS ARE OBSERVED TO
BE 2x4 CONSTRUCTION.
ALL EXISTING EXTERIOR WALLS ARE OBSERVED TO
BE 2x4 CONSTRUCTION.
Job Number:
24-006
Sheet Number:
A2.1
7 of 9
F-1
0
m
L
----------------------------------------
I
II
II
II
m II II
4:12
0
(E)
�AVE VENTS. VERIFY
PROVIDE ADDITIONAL
VENTING AS REQUIRED �.
II
L
/ OLYMPIC
HILLS
DRAFTING c�
DESIGN, LLC
Olympic Hills
Drafting &
Design, LLC
Seattle, NA
301.255.1841
N
W O
N
LO
(10
z
0
w
ry
H
z �
0 w
> U)
w 0
C� a
3: 1 2 (E) GABLE SAVE VENTS. VERIFY
— — — — ---1 ----- -- II
— — — — OR PROVIDE ADDITIONAL
VENTING AS REQUIREDLL
L
II � I III II II � >c�N�
II II I I III � �
Co
IL— -----I— J I I I EXISTING ROOF SLOPES I I O U Q
1 TO BE VERIFIED IN FIELD I I ctJ c6
I I I I III STRUCTURAL INFO NOTE
III VERIFY ALL STRUCTURAL INFORMATION N 5
SISTER 2x RAFTER (E) 2x4 _ I I _ I I III WITH STRUCTURAL PLANS BY OTHERS.
PEP, TROUCDTURAL 24"O.C. > V E
III STRUCTURAL PLANS ARE TO OVERRIDE
III ANY STRUCTURAL INFORMATION ON — co -
a 3: 1 2 I 3: 1 2 D I I III THE ARCHITECTURAL PLANS 0 -� LU
L_____ J�__ I II I'_I
F-------fir--- _ SISTER2xRAFTER ( 2x4_
TOP CHORD TKUS 2x I I I I I ROOF NOTF�
CEILING JOISTS@ 2 O.C.
PER STRUCTURAL I L _ _ _ _ _ _ _ — I ROOF OVERHANGS ARE TO BE UNCHANGED FROM
I r-� — — — — — EXISTING
SKYLIGHT Y I II I 11
OWNER/CONTRAC OR I I CEILING TO HAVE I I I CONTRACTOR
ROOF ING ERIAL IS TO BE PER OWNER OR
LOCATE PER OW R I I I _ _ 5/8" TYPE-X GWB,
— -- i FIRE -TAPED MIN i I _ _ _ _ _ = ROOF STRUCTURE IS TO BE (E) PRE -
MANUFACTURED TRUSSES @ 24" O.C. UNLESS
NOTED OTHERWISE Drawn: NAB
30x22 ATTIC ACCESS, SEE SFf UCT _ I I _ I I_ _ ATTIC SHALL HAVE VENTILATION EQUAL TO I SF
FOR HEADER OVER OPE INS 3- I/2" FL SH BEAM PER 150 SF OF ATTIC SPACE. VENTILATION SHALL Designed: NAB
BE PROTECTED FROM SNOW AND RAIN, AND SHALL
PER STR CTURAL I I I BE COVERED WITH A GALVANIZED WIRE SCREEN. Scale: AS SHOWN
OPENINGS SHALL BE LOCATED TO PROVIDE CROSS-
_ _ _ _ J_ — — _ — _ �� — J I VENTILATION. Date: 7/5/2024
PROVIDE ATTIC ACCESS PANEL WITH A MINIMUM
ROUGH OPENING OF 22N30" WITH A TIGHT FITTING,
SELF -CLOSING DOOR. DOOR MUST BE BACKED W/
(E) GA E EAVE V TS. VERI INSULATION IF LOCATED ABOVE HEATED SPACE.
OR PROVI DITIONAL VERIFY ACCESS LOCATION W/ OWNER.
1 VENTING AS REQUIRED
PROVIDE FULL DEPTH VENTED BLOCKING OVER
EXTERIOR WALLS AT EACH BAY
OVERALL ROOF PLAN
1 /4"=11-0" AS -BUILT NOTFS
CONTRACTOR IS RESPONSIBLE FOR ALL SHORING
AND TEMPORARY BEARING WALL PLACEMENT AND
CONSTRUCTION.
CONTRACTOR IS TO VERIFY DIMENSIONS OF ALL
REMOVED WALLS AND SLABS IN THE FIELD.
Job Number:
ALL EXISTING INTERIOR WALLS ARE OBSERVED TO 2 4 - O O 6
BE 2x4 CONSTRUCTION.
Sheet Number:
ALL EXISTING EXTERIOR WALLS ARE OBSERVED TO A3,0
BE 2x4 CONSTRUCTION.
8 of 9
F-1
DOOR 5GHEDULE
LABEL
aTY
FLOOR
51ZE
R/O
DESCRIPTION
COMMENTS
10010
1
1
10010
122"X87"
GARAGE-OARAGE DOOR CHD05
2668
1
1
2668 L
32"X82 1/2"
2 DR. BIFOLD-LOUVERED
2665
1
1
2665 L IN
32"X82 1/2"
HINGED -DOOR PO4
2665
1
1
2665 R
30"X50"
SHOWER -GLASS SLAB
2868
1
1
2868 L IN
34"X82 1/2"
HINGED -DOOR PO4
2868
1
1
2868 R IN
34"X82 1/2"
HINGED -DOOR PO4
3065
1
1
3065 L IN
35"X82 1/2"
HINGED -DOOR PO4
1
068 IN
"X 1/
ID -D 04
WINDOW 5GHEDULE
LABEL
aTY
FLOOR
SIZE
R/O
DE5GRIPTIOP
4 330
2
11
14030
14TX37
ILEFT 5LIDINC
5 1 HED
NUMBER
LABEL
IaTY
IrLOOk
IDESCRIFTION
601
2020
12
11
IRECT. SKYLIGHT
G02
2060
12
11
IRECT.5KYLIGHT
(E) ROOFING MATERIAL OVER
(E) ROOFING PAPER OVER
(E) ROOF SHEATHING
R-30 BATT INSULATION MIN PACK
FULL NO VOIDS W/ 2" R-1 0 CLOSED
CELL SPRAY FOAM AGAINST ROOF
SHEATHING
SISTER 2x 10 RAFTER TO (E) TRUSS
TOP CHORD PER STRUCTURAL
GUTTER FLASHING
OVER FASCIA
FASCIA
PER PLAN IpVpL
LJ
PROVIDE (N) SILL PER
STRUCTURAL DRAWINGS
AT NEW OPENINGS
(E)SHEATHING * SIDING
REPLACE AS NEEDED
(N) HEADER PER
STRUCTURAL PLAN
(N) OPENING�II \\ \\ I
Oil
--
�'
•
SIDING PER PLAN
WALL SHEATHING
(E) PT 2x4 SILL PLATE--\\
W/ ATTACHMENT
PER STRUCTURAL
(E) SLAB ON GRADE
(SOME LOCS)
L— ——
(1) 1 Od TOENAIL -
EA JOIST TO SLEEPER
raa a
PT SLEEPER @ 48" O.C.
BELOW FLOOR JOIST
ATTACH TO SLAB W/
(1) 1/4" DIA x 2" PINS
@ 48" O.C.
5/8" GWB
VERIFY OR PROVIDE H I
PER STRUCTURAL
(E) DBL TOP PLATES
1/2" GWB
(E) ROOFING MATERIAL OVER
(E) ROOFING PAPER OVER
(E) ROOF SHEATHING
SISTER 2x RAFTER TO (E) TRUE
TOP CHORD PER STRUCTURAL
3/4" T*G FLOOR
SHEATHING
FLUSH BEAM � CEILING
JOISTS PER STRUCTURAL
�—I .5" RIGID K-7.5 INSUL TION
ON VAPOR BARRIER
;ISTING GARAGE SLAB
50'"* - / //-
•
2x2 FURRING ATTACHED TO
(E)2x4 PER STRUCTURAL
K-1 0 RIGID INSULATION
AT HEADER GAP
2x2 FURRING ATTACHED TO
(E)2x4 PER STRUCTURAL
K-2 1 FACED BATT
INSULATION OR
LATEX PAINT
-1 /2" GWB
3/4" T*G
FLOOR SHEATHING
1 .5" RIGID K-7.5 INSULATION
ON VAPOR BARRIER
-'*`�iIII I III IEXISTING CONCRETE
SLAB ON GRADE
=111� L
III_ III
EXISTING FOUNDATION
(E) GARAGE NALL DETAIL
FURRING DETAIL
1 "=1 '-0"
(E) ROOFING MATERIAL OVER-
(E) ROOFING PAPER OVER
(E) ROOF SHEATHING
----- — — — — — — X
FASCIA^I
PE PLAN Ll
I II
(E) PRE -MANUFACTURED
TRUSSES @ 24" O.C.
EXISTING VENTING, VERIFY R-49 GATT
OR PROVIDE AS NEEDED I I I INSULATION
SHEATHING SIDING
REPLACE AS NEEDED
(E) HEADER PER
STRUCTURAL PLAN
(N) SHEATHING, -
REPLACE AS NEEDED
•
SIDING PER PLAN
(N) WALL SHEATHING
2x SILL PLATE
PT 2xG PLATE W/
ATTACHMENT
PER STRUCTURAL
(E) SLAB ON GRADE
(SOME LOCS)
5/8" GWB
VERIFY OR PROVIDE A35
PER STRUCTURAL
(E) DBL TOP PLATES
1/2" GWB
2x2 FURRING ATTACHED TO
(E)2x4 PER STRUCTURAL
W/ K-2 1 FACED BATT
INSULATION OR LATEX PAINT
K-1 0 RIGID INSULATION
AT HEADER GAP
(N) 2xG STUD WALL
PER STRUCTURAL
W/ K-2 1 FACED BATT
INSULATION OR LATEX PAINT
2xG STUD WALL INFILL
W/ K-2 1 FACED BAIT
INSULATTION OR
LATEX PAINT
-1 /2" GWB
3/4" T*G
FLOOR SHEATHING
1 .5" RIGID K-7.5 INSULATION
ON VAPOR BARRIER
I III a
a
=I I EXISTING CONCRETE
III=III I SLAB ON GRADE
c I' EXISTING FOUNDATION
(E) GARAGE V�ALL 2x6 INFILL
AT EXISTING OPENING
1 "=1 '-0"
K-30 BATT INSULATION (MIN) PACK
FULL (NO VOIDS), W/ 2" K-1 0 CLOSED
CELL SPRAY FOAM AGAINST ROOF
SHEATHING
2x4 CRIPPLE STUD
WALL PER STKUCT
30"x22" ATTIC ACCESS
LOC PER OWNER/
CONTRACTOR
\--5/8" TYPE-X GWB, FIRE -TAPED
MIN EXTERIOR FACE OF WALL
(N) BEARING INTERIOR JOGGED
PARTITION NALL G GARAG
E
E
1 "= 1 '-0"
(E) ROOFING MATERIAL OVER
(E) ROOFING PAPER OVER
(E) ROOF SHEATHING
DBL TOP PLATE
-GARAGE WARM WALLS
TO BE 2xG W/ R-2 1
FACED GATT INSULATION
OR LATEX PAINT
1 /2" GWB
(E) ROOFING MATERIAL OVER
(E) ROOFING PAPER OVER
(E) ROOF SHEATHING
SISTER 2x RAFTER TO (E) TKU`_
TOP CHORD PER STRUCTURAL
CONT LEDGER * CEILING
JOISTS PER STRUCTURAL
R-30 GATT INSULATION (MIN) PACK
FULL (NO VOIDS), W/ 2" R-10 CLOSED
CELL SPRAY FOAM AGAINST ROOF
SHEATHING
SISTER 2x (MIN 2x 1 0) RAFTER TO
(E) TRUSS TOP CHORD PER STRUCTURAL
DBL TOP PLATE
*
GARAGE WARM WALLS
TO BE 2xG W/ K-2 1
FACED BATT INSULATION
OR LATEX PAINT
5/8" TYPE-X GWB,
FIRE -TAPED MIN
1/2" GWB
EXTERIOR FACE OF WALL
(N) BEARING INTERIOR
PARTITION NALL
1 "= 1 '-0"
(a� GARAGE
(E) ROOFING MATERIAL OVER
(E) ROOFING PAPER OVER
(E) ROOF SHEATHING
---------------
FASCIA�VI X X
PER PLAN b I I PER PLAN I�
I II I II
(E) PRE -MANUFACTURED I (E) PRE -MANUFACTURED
TRUSSES @ 24" O.C. I I I TRUSSES @ 24" O.C.
EXISTING VENTING, VERIFY I I I EXISTING VENTING, VERIFY
OR PROVIDE AS NEEDED I I I OR PROVIDE AS NEEDED
(E) SHEATHING * SIDING
REPLACE AS NEEDED
(E) HEADER PER
STRUCTURAL PLAN
(N) SHEATHINGS SIDING
I
SIDING PER
WALL S H EAT
(N) PT 2x4 PLAT
ATTACH N
PER STRUCTL
(E) SLAB ON GF
(SOME L(
"=1 '-0"
5/8" TYPE-X GWB,
FIRE -TAPED, MIN
-VERIFY OR PROVIDE A35
PER STRUCTURAL
(E) DBL TOP PLATES
1/2" GWB
-(E) 2x4 STUD WALL
(N) 2x4 STUD WALL
PER STRUCTURAL
(E) SHEATHING * SIDING
REPLACE AS NEEDED
(N) HEADER PER
STRUCTURAL PLAN
(N) OPENING
5/8" TYPE-X GWB,
FIRE -TAPED, MIN
-VERIFY OR PROVIDE A35
PER STRUCTURAL
(E) DBL TOP PLATES
1 /2" GWB
-(E) 2x4 STUD WALL
. - - / . z/-
•
5/8" TYPE-X GWB,
2x4 STUD WALL INFILL FIRE -TAPED MIN
EXTERIOR FACE OF WALL
2xG SILL PLATE
?" GWB
PT 2x PLATE W/ 1 /2"8
AB's PER STRUCTURAL
CUT (E)SLAB TO POUR (N)FOOTING
PER STRUCTURAL CONTINUOUS
FOOTING
EXISTING CONCRETE
a I SLAB ON GRADE
III zi
EXISTING FOUNDATI(
GARAGE WARM WALLS
TO BE 2xG W/ K-2 1
FACED BATT INSULATION
OR LATEX PAINT
-1 /2" GWB
3/4" T*G
FLOOR SHEATHING
1 .5" RIGID R-7.5 INSULATION
ON VAPOR BARRIER
U° °
Iillliil a a a
- - a EXISTING CONCRETE
w • • SLAB ON GRADE
a
PER STRUCTURAL V V
/ OLYMPIC
HILLS
DRAFTING
DESIGN LLC
Olympic Hills
Drafting &
Design, LLC
Seattle, NA
301.255.1841
N
CD
0
ti
z
O
>
w
�
z
O
w
a
w
nn�
�
O
n
S
�
N
75
>
cn
v l
O
Q_��
CV
-�
CO
75
QD
G)
E
—
co
7
U
�
D--
Drawn: NAB
Designed: NAB
1
Scale: AS SHOWN
Date: 7/5/2024
Job Number:
24-006
Sheet Number:
A3.1
9 of 9