APPOVED PLN BLD RESUB2 BLD2024-0343+Architectural_Plan+6.18.2024_12.44.32_PM+43297011 . CODE -INTERNATIONAL EXISTING BUILDING CODE (IEBC) 20 18 EDITION. UNIFORM PLUMBING CODE (UPC) 2018 EDITION. INTERNATIONAL FIRE CODE (IFC) 2018 EDITION. 2020 NATIONAL ELECT. CODE (NEC) * STATE AMENDMENTS. 2. CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. 3. DO NOT SCALE THESE DRAWINGS FOR CRITICAL DIMENSIONS. ALL DIMENSIONS TO FACE OF STUDS AND FACE OF CONCRETE UNLESS OTHERWISE NOTED. 4. REPORT ERRORS AND / OR OMISSIONS TO THE DESIGNER IMMEDIATELY. 4-71 _LIFT 3 5. DO NOT VARY OR MODIFY THE WORK SHOWN, EXCEPT ON WRITTEN INSTRUCTION OF THE DESIGNER. ALL WORK SHALL CONFORM TO ALL LOCAL AND STATE BUILDING CODES AND ORDINANCES AND BE ENFORCED BY THE CONTRACTORS AT ALL TIMES. G. GENERAL CONTRACTOR SHALL PROVIDE PEDESTRIAN PROTECTION BARRICADES AND / OR CANOPIES AS REQUIRED BY THE LOCAL AUTHORITIES OR AS NECESSARY FOR PEDESTRIAN SAFETY. 7. DURING CONSTRUCTION CONTRACTORS SHALL PROVIDE AND MAINTAIN FIRE EXTINGUISHERS AS REQUIRED BY THE LOCAL FIRE DEPARTMENT FIELD INSPECTOR. 8. CONTRACTOR TO BE RESPONSIBLE FOR FLK. PATCHING, LEVELING * PREPARATION OF FLOOR FINISHES. 9. MAINTAIN A MINIMUM OF G" BETWEEN FINISH GRADE AND UNTREATED FRAMING MATERIALS. 10. FINISH GRADE SHALL SLOPE AWAY FROM BUILDING TOWARD DRAINAGE FACILITIES. 1 1. SLOPE ALL DECKS, WALKS AND PATIOS 1/47FT. MIN. AWAY FROM BUILDINGS. r 12. ALL LUMBER MUST BEAR AN APPROVED GRADING STAMP. w 13. ALL WOOD IN CONTACT WITH EARTH OR CONCRETE SHALL BE PRESSURE TREATED. 14. ALL EXPOSED EXTERIOR METAL SHALL BE PAINTED, GALVANIZED OR NONFERROUS. 15. ALL GLASS IN HAZARDOUS AREAS AND ALL GLASS WITHIN 1 8" OF FLOOR OR A DOOR OPENING SHALL BE APPROVED SAFETY GLASS. r I G. INTERIOR WALL AND CEILING FINISH FLAME SPREAD RATINGS SHALL CONFORM TO THE IRC.LU 17. TOILET ROOM WALLS TO BE FINISHED WITH MOISTURE RESISTANT MATERIALS TO A MIN. HEIGHT OF 70'' ABOVE LU FLOOR. FLOOR AND WALLS SHALL HAVE SMOOTH NON ABSORBENT SURFACES. o 18. ANY/ ALL NEW DUCT WORK SHALL BE CONSTRUCTED, ERECTED AND TESTED IN ACCORDANCE WITH THE MOST RESTRICTIVE LOCAL REGULATIONS AND PROCEDURES DETAILED IN ASHRAE HANDBOOK OF CIO FUNDAMENTALS OR THE APPLICABLE STANDARDS ADOPTED BY THE SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION. 19. MECHANICAL VENTILATION WILL BE A MINIMUM OF I 10 CFM FOR ALL FANS 20. EXHAUST DUCTS SHALL BE INSTALLED IN 2G GA. METAL DUCTS VENTED TO AN EXTERIOR TERMINAL WITH APPROVED BACK DRAFT DAMPER (K-4 INSUL.) 2 1. TOILET ROOMS TO INSTALL MECHANICAL VENTILATION CAPABLE OF PROVIDING 50 CFM AT 25 W.G. 22. THE DESIGNER DOES NOT ASSUME LIABILITY FOR UNSUITABLE SOIL CONDITIONS. THE OWNER SHALL CONDUCT TESTS TO DETERMINE THE SUITABILITY OF SUBGKADE SOILS FOR LOADS PROPOSED. 23. THE CONTRACTOR ASSUMES ALL KESPONSABILITY FOR VERIFICATION OF BUILDING CODE REQUIREMENTS AND ASSUMES ALL KESPONSABILITY FOR CONSTRUCTION DETAILS ONCE PERMIT IS ISSUED. 2018 Washington State Energy Code - Residential OBTAIN A SEPARATE Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions effective Febmary 1, 2021 - Vem on 11 PLUMBING PERMIT 1 � FROM THE CITY OF 1 ' EDMONDS. These requirements apply to all IRC building types, including detached one- and two-family ' dwellings and multiple single-family dwellings (townhouses). _._.._._.._._.._._.._._.._._.._._.._._.'1 ....................................... Project Information -__. Contoctln ormation f 1 1 OBTAIN ELECTRICAL ' - _-._-- -_ BUTLER RESIDENCE . _-_-_-- __- ---- - - - - - - - - -- -- _. - PERMIT FROM Obin Kearsle , Kearsley Homes Inc_ 731 NOKTH5TREAM LN EDMOND5, WA 98020 kearsle homes.com, 425-478-6380 STATE LABOR & • INDUSTRIES `0 Instructions: This single-family project will use the requirements of the Prescriptive Path below and o ' incorporate the minimum values listed. Based on the size of the structure, the appropriate number of - additional credits are checked as chosen by the permit applicant. 1 rovide all information from the following tables as building permit drawings: Table R402.1- Insulation and GUARDS SHALL NOT HAVE AN OPENING FROM THE WALKINGSURFACE ' TO THE REQUIRED GUARD HEIGHT THAT WILL ALLOW THE PASSAGE OF lLJ A 4"SPHERE IN ACCORDANCE WITH 2O21 IRC R312.1.3. z Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 406.3 - Energy Credits. -"-"-"-"-"...... ...... ...... ...... ......-"-"-"-"1 a/ .___.... .- _-_.........._--...._.._ ... ..__...- .. __. __._. _.. ... ...... ........... ... _........ ...._...._...... ....... ..... _._,.. ._..... ....__--___.-- - - - - WHERE ADDITIONS OR ALTERATIONS REQUIRE A PERMIT 1 Q__ TO BE ISSUED INTERCONNECTED SMOKE ALARM AND CO O l 'Authorized Representative Date _ ._ _ _ _ f37�� /2024 DETECTORS THROUGHOUT THE DWELLING IS REQUIRED. • , REFER TO 2021 IRC R314 AND 315 FOR MORE 1 INFORMATION 1 1 _..... - Climate Zones Table All R402.1.1 ; - - - - - I R-Y-aIMe a 3 U-Factor -_._-:-.....__. 1 1 HARDWARE & FASTENERS IN CONTACT WITH PRESERVATIVE -TREATED 1 WOOD SHALL BE OF HOT -DIPPED ZINC GALVANIZED STEEL STAINLESS 1 STEEL, SILICON BRONZE OR COPPER. IN THE ABSENCE OF F Fe-nestration U-Factor b n/a 0�30 1 MANUFACTURER'S RECOMMENDATIONS A MINIMUM OF ASTM A 653 TYPE G185 ZINC -COATED GALVANIZED STEEL, OR EQUIVALENT, SHALL BE USED. _ IRC R317 3.1 IBC 2304.10 51 1 1 i Skylight U-Factor n/a 0.50 �_.._.._ _.._.._.._._.._.._ _.._.._.._ _.._.._.._.._.._... Glazed Fenestration SHGC b.e n/a n/a - - - - ---- - -- - --- - ...... Ceiling e 49 0.026 Wood Frame Wall 9-h 21 int 0.056 Floor 30 0.029 Below Grade Wall `•h 10/15/21 int + TB i 0.042 _ Slab', R-Value & Depth 10, 2 ft n/a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity that is less %ROPER 85.g9, 1 6' BL/RtiNGTON NORTHER N RIGHT OF WqY N OONTOURLINES -------- co 26' - 0'1 20' LO � o EXISTING CONCRETE PATIO , 04 co _Q a ° 25 S�BACK LINE d a NEW ROOF OVERHANG ON - FUPPER LOOK 1 9'-2"X2'-39 22 ,' `.. a '°. '- , , _ "'EX 5QF • _ d � ° ISTING ROOF � T OVERHANG OF LOWER FLOOR 19' - 2" 60'-101ra -- -------------- a - a ° - _----------- - -1 r- °d-- ° r 9'- 6 1/2"1� N I Q w > 0 N = N O z_ LXLI 24' EXISTING ROOF 2'- 0" 10' " - 1 OVERHANG 12' - 1" I -NE ION STING AIN UFF FLOOR O F FLOOR O SIDE ARE LL -NE COVERE DEC z I W 2ND FL R o w l. OUTSIDE WALL z C TIN HOU 73 db I 7-77 °- ROOF OVERIIANG __77 ° - It`d ° • �d°• � z - v a _ d f a '1-^ a I -d� X 4- a J ° I 20 a° d. c(3 tu do ';° d EXISTING CONCRETE DRIVEWAY . ° _ - .� GARAGE co d° d - -`a °,d •..P a, ° d� � n a. " d ` Q a -- ° - SETgPGK�tNE _ 1 °_ I 9- a• d: a _ - q ° ° . °d ° ° I" a _ I I, as d a 28'------- ° d 8 -- °,d . q ro d° a rn POWER d _ - _ _ 4 "qd -�= ° DN PROPERTY LINE +/- 3G. It WATER METER a P�OP�1I y Of Edmonds Building Department NORTH5TREAM LN, DEAD END CUL-DU-SAC a 'than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix p Table A101.4 shall not be less than the R-value specified in the table.I T I LAN N __.___.._ -'__-- ALL WORK SUBJ 'T b The fenestration U factor column excludes skylights _ -- - - -_ _..- .._.._. _ _ . TO FIELD '10/15/21 +5TB" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on INSPECTION FOWALE: 1 " = 20'-0" the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at CODE COMPLIANCE c the interior of the basement wall. "10/15/21 +5TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB" means R-5 thermal break between floor slab and basement wall. --_-__ __..- _ _-__-_-__--- - ___ -_ _ __- _ _--- _.. . d R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1. 2018 ENERGY CODE INFORMATION ENERGY CREDITS KEQD, PER For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth K-40G. 2 e extends over the to late of the exterior wall -- -- P P_ _ -. _ _-- _.___.----__-- -- ___-- - -__-_------_-----_..__ - ___-- _------.-__. _------_--___-------- ----....------- - ____. R40G.3 A RESIDENTIAL BUILDING SHALL COMPLY WITH SUFFICIENT R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter OPTIONS FROM TABLE R40G.2 SO AS TO ACHIEVE THE FOLLOWING f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall M UM BER CKED ADD NS L THA EQ _ _meet the requirements for thermal barriers protecting foam plastics. ___ -. -_ __ _ _ TO 50 SQUA FEET 1 .5 CR DITS For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for 2 -HEATING OPTIONS, FUEL NORMALIZATION DESCRIPTIONS, HEAT g climate zone 5 of ICC 400. _ _ - PUMP, 1.0 Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard 3. - H I EN AC PT OPT h iframing 16 inches on center, 78% of the wall cavity insulated and headers insulated with a minimum of R-10 -DUCTLESS MINI -SPLIT HEAT PUMP SYSTEM, ZONAL CONTROL: IN insulation. HOMES WHERE THE PRIMARY SPACE HEATING SYSTEM IS ZONAL ELECTRIC HEATING, A DUCTLESS MINI -SPLIT HEAT PUMP SYSTEM WITH A MINIMUM HSPF OF 10.0 SHALL BE INSTALLED AND PROVIDE HEATING TO THE LARGEST ZONE OF THE HOUSING UNIT. TOTAL: 1.5 CREDITS Dr1RWOptl,n P09et to D Z Work ADDITION AND DECK Address 731 NORTHSTREAM LANE Owner BUTLER Approved Date 06/27/2024 ------------------------- Building Official Permit Numbest,,,, BL Q2024-0343 a� s ® �a o� 0 1 90th PIS"' PSTJS Cherry St Cherry St Cherry St .z" v' 2 3 v a O s P f 0 z Somerset Ln Z Northstream Ln Z a' Q aet Dr Puget Way m i a 0 Cascadia Foodshed Financing Project Q am f 0 Q�2 0 F oo�a P 3� je C�daY Q o\�F Portofino Restaurant & Bar ® DI®pic View Den Italian • SS Q 0 3 Qo all,3 Forest Dell Dr Excelsior PI PlgetD BUTLER RESIDENCE PROPERTY ADDRESS: 731 NOKTHSTKEAM LN EDMONDS, WA 98020 PARCEL # : 0053250000900 PROJECT DESCRIPTION: NEW ADDITION TO THE UPPERFLOOK AND NEW PROPOSED UPPER FLOOR DECK PROJECT TEAM LEGAL DESCRPTION : NOKTHSTREAM LANE BLK 000 D-00 -LOT 9 SUBJ OWNER ESE PUD I - WEST COAST TELE ARCHIE LINDA BUTLER 73 I NORTHSTREAM LN LOT 51ZE:.2G ACRES, 1132G SQFT EDMONDS, WA 96020 ZONING: RS- 12 ARCHITECTUAL DRAWINGS KEARSLEY HOMES INC. ROBIN KEARSLEY GG3 1 NORMA BEACH RD. EDMONDS, WA 9602G 425-478-G380 R@KEARSLEYHOMES.COM STRUCTUUAL ENGINEER CJK ENGINEERING CLEMNS ROSWELL 425-2G9-5204 INFO@CJRENG.COM FLOOR AREAS: EXISTING HEATED SPACE: MAIN FLOOR = 2,728 SQFT UPPER FLOOR = 534 SQFT TOTAL EXISTING = 3,2G2 SQFT NEW ADDITION TO HEATED SPACE UPPER FLOOR = 278 SQFT TOTAL EXISTING + NEW = 3,540 SQFT EXISTING UNHEATED SPACE: GARAGE = 707 SQFT NEW ADDITION TO UNHEATED SPACE: UPPER FLOOR DECK = 202 SQFT TOTAL EXISTING + NEW = 909 SQFT INSULATION VALUES PER EFFICIENT BLDG. ENVELOPE I A GLAZING U-0.28 SKYLIGHT U-0.35 CEILING (VAULT D) K-38 CEILING (FLAT) R-49 EXTERIOR WALL K-2 1 FLOOR R-38 SLAB ON GRADE R- 10 PERMIETER SLAB SLAB BELOW GRADE K- 10 PERIMETER * SLAB K-VALUES ARE MINIMUMS, U-FACTORS ARE MAXIMUMS REPLACE TWO EXISTING FOOTINGS CUT= .7 YARDS FILL = .7 YARDS SHEET INDEX A 1.0 - SITE PLAN TITLE SHEET A I . I - SWPPP A2.0 - EXISTING FLOOR PLANS A3.0 - PROPOSED MAIN FLOOR PLAN A3. 1 - PROPOSED UPPER FLOOR PLAN A3.2 - FOUNDATION PLAN A3.3 - FRAM I NG PLAN A3.4 -ROOF PLAN A4.0 - CROSS SECTION A5.0 - NORTH * SOUTH ELEVATION A5. 1 - EAST WEST ELEVATIONS LAND USE CODE: I I 1 SINGLE FAMILY RESIDENCE - DETACHED S-T-R: 27-03-1 3-SW STRUCTURAL DESIGN CRITERIA 2016 IRC, IMC, UPC.20 1 7 NEC, W5EC-K-201 7 DESIGN CRITERIA FOR EDMONDS Min. Roof Snow Load 25 psf (non -reducible) Ground Snow Load 25 psf (non -reducible) Seismic Design Category D1(Residential) / Category D (Commercial) Wind Speed 85 mph (Basic). 110mph (Ultimate) Wind Exposure B,C & D (varies with location contact plan review staff) Winter Design Temp 27 degrees F (-3 degree C) Mean Annual Temp 50 degrees F (10 degree C) DEAD LOADS FLOOR= 12 PSF ROOF= 15 PSF EXT. WALL= 12 PSF INT. WALL= 10 PSF FLOOR LIVE LOAD= 40 PSF DECK LIVE LOAD= GO PSF EXISTING LOT COVERAGE FOOTPRINT OF HOUSE t HOU5E t GARAGE TOTAL GARAGE 2,973 5QFT 2,973 5QFT 2,973 5QFT = I I ,32G SQFT = 2G% ADDITIONAL NEW LOT COVERAGE FOOTPRINT OF HOUSE UPPER FLOOR 3 1 5QFT = 1 3 1 51 1 ,32G 5QFT = .2% TOTAL LOT COVERAGE = 31004 5QFT3 2G.2% EXISTING IMPERVIOU5 ARFA5 LOT COVERAGE 21973 5QFT ROOF OVERHANG 55 1 5QFT REAR CONCRETE PATIO G47 5QFT FRONT DRIVEWAY 2,257 5QFT NORTH GRAVEL WALKWAY 407 5QFT `SOUTH GRAVEL WALKWAY 205 5QFT TOTAL 71040 5QFT ADDITIONAL NEW I MPERVIOU5 ARFA5 NEW SECOND FLOOR AREA 39 5QFT TOTAL 39 5QFT TOTAL IMPERVIOUS AREA= 7,079 5QFT EXI5TING HARD5CAPE ARFA 75040 50FT = I I 332G 50F" = G2% ADDITIONAL NEW HARD5CAPE AREA 39 5QFT = I I ,32G 5QFT = .3% TOTAL HARDSCAPE AREA = G2.3% z 0 ►--� U Q °o>, O U� z �1 00 cli en Q r" ^w I --I 0 CV lJ U z > L1J 6 21 C) z O o LU w CZ z J Q W rV J C o m z Q J L1J LU LU LLJ J RESUB Jun 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DRAWN BY: DATE: RK 5/20/23 REVISED BY: DATE: RK 1112GI23 REVISED BY: I DATE: REVISED BY:1 DATE: I AI .0 a - E O Z 1 . CODE -INTERNATIONAL EX515TING BUILDING CODE (IEBC) 2018 EDITION. UNIFORM PLUMBING CODE (UPC) 2018 EDITION. INTERNATIONAL FIRE CODE (IFC) 2018 EDITION. 2020 NATIONAL ELECT. CODE (NEC) * STATE AMENDMENTS. 2. CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. 3. DO NOT SCALE THESE DRAWINGS FOR CRITICAL DIMENSIONS. ALL DIMENSIONS TO FACE OF STUDS AND FACE OF CONCRETE UNLE55 OTHERWISE NOTED. 4. REPORT ERRORS AND / OR OMISSIONS TO THE DESIGNER IMMEDIATELY. 5. DO NOT VARY OR MODIFY THE WORK SHOWN, EXCEPT ON WRITTEN INSTRUCTION OF THE DESIGNER. ALL WORK SHALL CONFORM TO ALL LOCAL AND STATE BUILDING CODES AND ORDINANCES AND BE ENFORCED BY THE CONTRACTORS AT ALL TIMES. G. GENERAL CONTRACTOR SHALL PROVIDE PEDESTRIAN PROTECTION BARRICADES AND / OR CANOPIES A5 REQUIRED BY THE LOCAL AUTHORITIES OR A5 NECESSARY FOR PEDESTRIAN SAFETY. 7. DURING CONSTRUCTION CONTRACTORS SHALL PROVIDE AND MAINTAIN FIRE EXTINGUISHERS A5 REQUIRED BY THE LOCAL FIRE DEPARTMENT FIELD I N5PECTOK. 8. CONTRACTOR TO BE RESPONSIBLE FOR FLK. PATCHING, LEVELING * PREPARATION OF FLOOR FINISHES. 9. MAINTAIN A MINIMUM OF G" BETWEEN FINISH GRADE AND UNTREATED FRAMING MATERIALS. 10. FIN15H GRADE SHALL SLOPE AWAY FROM BUILDING TOWARD DRAINAGE FACILITIES. 1 1. SLOPE ALL DECKS, WALKS AND PATIOS 1/4"/FT. MIN. AWAY FROM BUILDINGS. 12. ALL LUMBER MUST BEAR AN APPROVED GRADING STAMP. 13. ALL WOOD IN CONTACT WITH EARTH OR CONCRETE SHALL BE PRESSURE TREATED. 14. ALL EXF05ED EXTERIOR METAL SHALL BE PAINTED, GALVANIZED OR NONFERROUS. 15. ALL GLA55 IN HAZARDOUS AREAS AND ALL GLA55 WITHIN 1 8" OF FLOOR OR A DOOR OPENING SHALL BE APPROVED SAFETY GLASS. I G. INTERIOR WALL AND CEILING FIN15H FLAME 5PREAD RATINGS SHALL CONFORM TO THE IRC. 17. TOILET ROOM WALLS TO BE FINISHED WITH MOISTURE RESISTANT MATERIALS TO A MIN. HEIGHT OF 70" ABOVE FLOOR. FLOOR AND WALLS SHALL HAVE SMOOTH NON ABSORBENT SURFACES. 18. ANY/ ALL NEW DUCT WORK SHALL BE CONSTRUCTED, ERECTED AND TESTED IN ACCORDANCE WITH THE M05T RESTRICTIVE LOCAL REGULATIONS AND PROCEDURES DETAILED IN A5HKAE HANDBOOK OF FUNDAMENTALS OR THE APPLICABLE STANDARDS ADOPTED BY THE SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION. 19. MECHANICAL VENTILATION WILL BE A MINIMUM OF I 10 CFM FOR ALL FANS 20. EXHAUST DUCTS SHALL BE INSTALLED IN 2G GA. METAL DUCTS VENTED TO AN EXTERIOR TERMINAL WITH APPROVED BACK DRAFT DAMPER (R-4 IN5UL.) 2 1. TOILET ROOMS TO INSTALL MECHANICAL VENTILATION CAPABLE OF PROVIDING 50 CFM AT 25 W.G. 22. THE DESIGNER DOES NOT ASSUME LIABILITY FOR UNSUITABLE 501L CONDITIONS. THE OWNER SHALL CONDUCT TESTS TO DETERMINE THE SUITABILITY OF 5UBGKADE SOILS FOR LOADS PROPOSED. 23. THE CONTRACTOR ASSUMES ALL KE5PON5ABILITY FOR VERIFICATION OF BUILDING CODE REQUIREMENTS AND ASSUMES ALL RE5PON5ABILITY FOR CONSTRUCTION DETAILS ONCE PERMIT 15 ISSUED. 5WPPP ELEMENT 1: PRESERVE VEGETATION/MARK CLEARING LIMITS LAND D15TUKBING ACTIVITIES FOR DEVELOPMENT ARE ALLOWED ONLY IF CONDUCTED PURSUANT TO A 5WPPP THAT ESTABLISHES THE PERMITTED AREAS OF LAND D15TURBING ACTIVITY. WHEN ESTABLISHING THESE LAND D15TURBING ACTIVITY AREAS, CONSIDERATION SHALL BE GIVEN TO MINIMIZING THE REMOVAL OF EXISTING TREES AND MINIMIZING DISTURBANCE AND COMPACTION OF NATIVE SOILS, EXCEPT A5 NEEDED FOR BUILDING PURPOSES. THE DUFF LAYER, NATIVE TOP SOIL, AND NATURAL VEGETATION SHALL BE RETAINED IN AN UNDISTURBED STATE TO THE MAXIMUM DEGREE PRACTICABLE. -BMP C 1 01 : PRESERVING NATURAL VEGETATION -BMP C 1 04: STAKE AND WIRE FENCE -BMP C233: 51LT FENCE 5WPPP ELEMENT 2: ESTABLISH CONSTRUCTION ACCESS CONSTRUCTION VEHICLE INGRESS AND EGRE55 SHALL BE LIMITED TO ONE ROUTE, WHEN POSSIBLE. -EXISTING ENTRANCE TO PROPERTY 15 THE ONLY ONE THAT WILL BE USED FOR CONSTRUCTION VEHICLES. 5WPPP ELEMENT 4: INSTALL SEDIMENT CONTROLS IF THERE 15 RUNOFF FROM THE CONSTRUCTION SITE, SEDIMENT SHALL BE REMOVED FROM THE RUNOFF. -A 51LT FENCE AND/OR A STRAW BALE BARRIER WILL BE INSTALLED AROUND AREAS OF THE NEW FOUNDATIONS -BMP C230: STRAW BALE BARRIER -BMP C233: 51LT FENCE 5WPPP ELEMENT 5: STABILIZE SOILS THE APPLICANT SHALL STABILIZE ALL EXPOSED AND UNWORKED SOILS THROUGH THE APPLICATION OF BMP5 PURSUANT TO VOLUME II, CHAPTER 4 OF TH15 MANUAL. -SOILS ARE ALREADY 5TA15ALIZED DUE TO THE EXISTING FOUNDATION BEING CONSTRUCTED 5WPPP ELEMENT G: PROTECT SLOPES CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH CHAPTER 30.G3B 5CC AND IN A MANNER THAT WILL MINIMIZE ER05ION AND COMPLY WITH THE COUNTY'5 APPLICABLE CRITICAL AREA REGULATIONS. CUT AND FILL SLOPES SHALL BE PROTECTED FROM EROSIVE AND CONCENTRATED FLOWS UNTIL PERMANENT COVER AND DRAINAGE CONVEYANCE SYSTEMS ARE IN PLACE. -NO STEEP SLOPES ON PROPERTY 5WPPP ELEMENT 7: PROTECT PERMANENT DRAIN INLETS ALL PERMANENT STORM DRAIN INLETS REQUIRE PROTECTION FROM SEDIMENT AND 51LT-LADEN WATER. -BMP C220: STORM DRAIN INLET PROTECTION 5WPPP ELEMENT 8: STABILIZE CHANNELS AND OUTLETS TEMPORARY AND PERMANENT CONVEYANCE SYSTEMS AND THEIR OUTLETS SHALL BE PROTECTED AND STABILIZED TO PREVENT EROSION DURING AND AFTER CONSTRUCTION. -FOUNDATION WORKTO BE COMPLETED IN JULY OR AUGUST OF 2022 5WPPP ELEMENT 9: CONTROL POLLUTANTS THE 5WPPP SHALL SHOW HOW ALL POLLUTANTS, INCLUDING WASTE MATERIALS AND DEMOLITION DEBRIS, SHALL BE HANDLED AND DISPOSED OF IN A MANNER THAT DOES NOT CONTAMINATE 5TORMWATER. -BMP C 15 1: CONCRETE HANDLING -BMP C 1 52: 5AWCUTTING AND SURFACING POLLUTION PREVENTION -BMP C 1 53: MATERIAL STORAGE, DELIVERY, AND CONTAINMENT 5WPPP ELEMENT 1 1: MAINTAIN BEST MANAGEMENT PRACTICES 5WPPP ELEMENT I I ESTABLISHES REQUIREMENTS REGARDING THE MAINTENANCE OF BMP5. THE 5WPPP SHALL PROVIDE FOR INSPECTION AND MAINTENANCE OF THE CONSTRUCTED BMP5. THE APPLICANT SHALL MAINTAIN 13MP5 AND COMPLY WITH THEIR REMOVAL AT THE END OF THE PROJECT. -BMP C 1 50: MATERIALS ON HAND 5WPPP ELEMENT 1 2: MANAGE THE PROJECT THE 5WPPP NARRATIVE SHALL DESCRIBE HOW THE PROJECT 51TE SHALL BE MANAGED FOR 501L EROSION AND SEDIMENTATION CONTROL THROUGHOUT THE LIFE OF THE PROJECT. -BMP C 1 50: MATERIALS ON HAND 5WPPP ELEMENT 1 3: PROTECT ON-51TE 5TORMWATER MANAGEMENT BMP5 FOR RUNOFF FROM ROOFS AND OTHER HARD SURFACES ON-51TE 5TORMWATER MANAGEMENT BMP5 USED FOR RUNOFF FROM ROOFS AND OTHER HARD SURFACES INCLUDE: FULL DISPERSION, ROOF DOWNSPOUT FULL INFILTRATION OR D15PEK51ON SYSTEMS, PERFORATED 5TUB0UT CONNECTION5, RAIN GARDENS, BIORETENTION SYSTEMS, PERMEABLE PAVEMENT, 5HEETFLOW DISPERSION, AND CONCENTRATED FLOW DISPERSION. -BMP C233: SILT FENCE -BMP C234: VEGETATED STRIP GENERAL CONSTRUCTION 5TORMWATER POLLUTION PREVETION PLAN (5WPPP) 1() Preserve Vegetation/Cover Soils. A) Preserve as much native vegetation as possible. Be sure to observe clearing and grading limits, and comply with all city vegetation preservation and stream/wetland setback requirements. Time the clearing so it occurs no sooner than necessary for subsequent construction activities. B) Provide temporary vegetation/cover as needed. Examples of this include: temporary seeding/ hydroseeding; mulch, such as hay straw, or wood fiber; mats/blankets, such as jute mat excelsior; woven straw blanket; or netting; plastic sheeting with anchors. C) Provide permanent vegetation cover as soon as earthwork is complete (seeding or hydroseeding or sodding. H) Control Runoff During Construction: Reduce runoff velocities. Techniques include: vegetating exposed soils and ditches; riprap; check dams including straw bales, rocks, pea gravel bags, and sand bags; terracing or contouring the site; and filter fabric fencing. III) Install and Maintain Sediment Controls. A) Install sediment controls such as: 1) lower cost (non -engineered), filter fabric fence, check dams, rock berms, sediment traps, and catch basins and drain filters. 2) moderate cost (engineered), intercepting ditches, cut-off trenches, level spreader, and gradient terracing/contouring. 3) Higher cost (engineered), siltation/sedimentation pond, grass -lined swale or constructed wetland. B) Maintain sediment controls by frequent inspection of control facilities to make sure they are working properly (trapping sediment on - site, with water leaving site clear), and removing collected sediment as needed from sediment traps. IV) Keep Fresh Concrete Mortar out of Storm Drains and Streams. A) Use designated wash -out areas. B) Take care when building concrete aggregate driveways making sure to wash out the fines to the side, not down the driveway. If the driveway is sloped, place straw bales at the bottom or divert flow to a safe sediment basin. C) Never wash fresh concrete mortar into the storm drain or a stream. V) Keep Business and Work Areas Clean and Maintain Catch Basins. Examples include: picking up litter, sweeping surfaces which drain to storm drain, using a tarp to cover the ground when sanding to catch chips, cleaning up all wastes at the work site, maintaining construction equipment to fix any oil leaks, installing and maintaining an oil/water separator, covering all stock piled materials, and cleaning catch basins. VI) Cover Containers and Materials. A) Cover all potentially polluting materials such as dumpsters, waste container drums, tanks, boxes, chemicals, paints. solvents, stockpiles of lumber, other building material, metal products, top soil, and landscaping materials. B) Cover adequately by developing good storage areas that keep materials covered so pollutants can't wash away during rain or snow. VH)Prepare For and Clean Up Spills. A) There are three overall practices to minimize pollution from spills: 1) Handle materials carefully to avoid spills and leaks, 2) Prepare a clean up plan, and 3) Immediately clean up any spills. When preparing a clean up plan make sure to: a) Establish who to notify in the event of a spill, b) Provide specific clean up instructions, c) Assign a person to be in charge of clean up, and d) Prepare spill containment and clean up kits which are easy to reach and use. Remember to clean up spills immediately, and observe clean up plans and safety requirements. If there isn't a plan, take the following steps: 1) Stop or isolate the source of the spill, 2) If there's a chance the spill could enter the storm drain or sewer, close drain inlet and divert any incoming water. 3) Cover the spill with absorbent material(s) that can be easily swept or picked up such as kitty litter, sawdust, or vermiculite (make sure that materials used for hazardous waste clean up are treated as hazardous waste for disposal), and 4) Report spills to City of Edmonds Engineering Division, Hydraulics Engineer at 425- 771-0220: or for large spills, contact Department of Ecology at 425-649-7000. VIII)Dispose of Wastes Properly. Proper waste disposal depends on both the properties and the amount of the waste. To dispose of waste: 1) Identify if it is hazardous, 2) Estimate the amount in pounds, 3) Determine the disposal method, and 4) If necessary, contact a hazardous waste service. This is a very broad subject and if you have any questions about waste disposal contact the City of Edmonds Recycling Coordinator at 425-771-0235; or the Snohomish County Household Hazardous Waste Disposal Station at 425-388-6050. IX) Minimize Waste. Wastes can be minimized through good housekeeping, separating different wastes, substituting non -hazardous materials in the place of hazardous ones, and maintaining products and construction equipment. Reducing wastes reduces potential sources of pollutants to the drainage system and also preserves natural resources. The following are a few ideas: 1) Use solvents more than once, 2) Buy the least toxic products available, 3) Buy only what you need and use only what is needed, 4) Purchase products that last longer (better quality), and 5) See if others can use your waste (use the services of the Industrial Materials Exchange 206-296- 4899), for more information contact the City of Edmonds Recycling Coordinator at 425-771-0235. X) Recycle Unwanted Materials. Unwanted materials produced at Construction sites can often be recycled, at less cost than conventional disposal methods. The City has recycling guides available regarding construction, demolition, and land clearing (CDL) activities. The recycling guide lists sites that accept CDL materials, and outlines how to se -up worksite recycling. Other ways to make recycling work are: 1) Purchase recycled products, 2) Separate wastes, 3) Avoid phenol, 4) Keep receipts, and 5) Recycle what you can. XI) Preserve/Enhance Streams, Wetlands, and Adjacent Vegetation. Protect streams and wetlands, remember, stream and wetland protection is required by City of Edmonds Codes. Contact City of Edmonds, Planning Division at 425-771-0220 for more information. XII)Educate Employees and Customers. Participate in workshops, courses, and knowledge transfer. Conduct annual water quality training sessions for all employees. Include water quality training in new -employee orientations and in written procedures. Make sure customers are aware of BMPs, and explain BMPs to peer businesses. Remember, water quality is the responsibility of everyone. 4-7 1 -LIFT 3 w 0 z 0 LU w U z 0 U Lol 5 0 �t UJ z ILI W 0 pROPE R�LlNE 85.g,9, BURLINGTON NORTHER N R/GNT OF wAY -STOCKPILE DIRT FROM EXCAVATION OF TWO FOOTINGS. -COVER WITH 6 MIL N - " V15QUEEN WITHIN 24HR5 OF M EXCAVATION io -AS PER BMP C 123 CONTOUR LINES -------------------- 26' - 0" - 20 -- e 0 EXISTING CONCRETE PATIOS A' CM S�BqcK /NE' 4 NEW ROOF OVERHANG ON ad _ ° d UPPER FLOOR 19'-2"X2'=39 22' -- ' - b �' ° °EXISTING ROOF SQFT OVERHANG OF ° d LOWER FLOOR 19' - 2" 60' - 10" � -- ---------------- r----------- - o d EXISTING ROOF OVERHANG 19'-9" -NEW EXTENSION ON UPPERFLOOP, OF ROOF AREA. -NEW COVERED DECK AREA EXISTING HOUSE, 731 18'-9" 2'-0" 10'-l" 12'-1" EXISTING MAIN FLOOR OUTSIDE WALL NEW 2ND FLOOR J I I o zD 0 1 OUTSIDE WALL 0 1 o O1 ,. m °i- 1 ' � Q I I � I Q N 1 I 1 N W I > 1 � � i U z d �^----- _• I I C)-----------------7' - ROOF OVER ANG ?°° I 1 z I I X lu as ° N I I z I I 26' m �d, a• _ a•,I I v m o a EXISTING CONCRETE DRIVEWAY . °° " °M _ a ,� GARAGE ° d ° d 25 5�56PG� UNE I 1 12' a a °22' - 4 2b' ° d • ° `EXISTING CONCRETE a` ° - • d :DRIVEWAY TO BE USED°_'_� POWER ------ AS CONSTRUCTION d a" - ° 'ENTRANCE' - DIN AS PER BMP C 105 d PROPERTY LINE +/- 36. IWATER METER UN� +I- A-7 1 2 F '?t :N NORTHSTREAM UN, DEAD END CUL-DU-SAC z O i-� U Q O CAIzQ� Z M W Ib r- N W Q O CV W 0 U z � L1J C) o r- O V J C) 11J w r/ z ^ / J L.L Q LU LLJ J L O c� z Q J LL1 � I- W 5WPPP PLAN N W SCALE: 1 " = 20'-0" -ALL EXISTING DOWNSPOUT LOCATIONS TO REMAIN BEST MANAGEMENT PRACTICES: W BMP C 1 01 - PRESERVE EXISTING VEGETATION HOUSE BMP C 12 1 - MULCHING, FILL IN DISTURBED AREAS W/ AMENDED SOILS MULCH roof COO C BMP T 10 I -TREE PROTECTION, NOT APPLICABLE downspout C BMP C233 -SILT FENCE, NOT APPLICABLE serves up BMP C 123 - STOCK PILE MAAGEMENT, EXCAVATED MATERIAL COVERED to 700 s.f. �OOCC W/ PLASTIC SHEETHING, .7 CUBIC YARDS FROM EXCAVATION OF NEW of roof ADO C FOOTINGS 50' min. BMP C 105 - MANAGEMENT OF VEHICLE TRACKING OF SEDIMENT, USE RESUB vegetated OOC 000C EXISTING CONCRETE DRIVEWAY Jun 18 2024 flow path �O= BMP C220 - INLET PROTECTION, NOT APPLICABLE - STREET INLET IS CITY OF EDMONDS HIGHER THAN FLOOR LEVEL OF EXISTING HOUSE BY APPROX. 8' SERVI DEVELOPMENT CES DEC DEPARTMENT splash block "',- - downspout extension NTS splash block TYPICAL DOWNSPOUT 5PLA5HBLOCK D15PEK51ON NTS DRAWN BY: DATE: RK 5/20/23 REVISED BY: DATE: RK 1112GI23 REVISED BY: I DATE: REVISED BY: I DATE: I AI.I 1Q'_91, 9R'_1n„ 14'_-'V' GENERAL NOTE_ - GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL EXI5TING AND NEW UTILITIES AND 51TE CONDITIONS BEFORE AND DURING GON5TRUCTION. INFORM ARCHITECT/DE5I6NER OF VARIATION5 BETWEEN CONTRACT DOGUMENT5 AND EXI5TING CONDITION5. - DO NOT 50ALE DRAWIN65; VERIFY ALL DIMEN51ON5 ON THE JOB. - DIMEN51ON5 ARE TO FACE OF FOUNDATION WALL5 AND FACE OF ROUGH FRAMING, UNLE55 NOTED OTHERWI5E. - FLOOR -TO -FLOOR DIMEN51ON5 FROM TOP OF 5UBFLOOR TO TOP PLATE5, UNLE55 NOTED OTHERWI5E. - PROVIDE 50LID BLOCKING BEHIND ALL WALL HUNG FIXTURES AND ACCE55ORIE5. - PROVIDE 2" 5TRIP VENT5 @ ALL CANTILEVERED AREAS. - OPENIN65 SHALL BE CAULKED, SEALED, OR WEATHER5TRIPPED. - 5EAL TEAR5 AND JOINT5 IN INSULATION WITH TAPE. - 5HOWER FLOW CONTROL LIMITED TO 2.5 GPM. - M015TURE CONTROL TO BE PROVIDED PER WA5HINGTON STATE ENERGY CODE. - 5ERVICE WATER PIPES IN UNHEATED 5PACE5 5HALL BE IN5ULATED PER WA5HINGTON STATE ENERGY CODE. - MINIMUM 6 MIL VI50UEEN GROUND COVER REQUIRED IN CRAWL 5PAGE, LAPPED 12" AT JOINTS. - PROVIDE FIRE BLOCKING, DRAFT5TOP5 AND FIRE5TOP5 PER THE INTERNATIONAL RE51DENTIAL CODE - ALL NAILIN6/FA5TENER5 PER INTERNATIONAL RE51DENTIAL CODE - PROVIDE APPROVED 5ECUR17Y AND LOGKING DEVIGE5 AT NEW DOORS AND WINDOWS PER IRG - VERIFY SMOKE DETEGTOR5 IN5TALLED PER IRG - PROVIDE OUT5IDE AIR 5OURCE WITH MINIMUM 4 50UARE INCH VENTILATION INLETS FOR EACH HABITABLE ROOM. GENERAL NOTES: I. CONTRACTOR SHALL VERIFY ALL NOTES, DIMEN51ON5 d CONDITION5 PRIOR TO CONSTRUCTION 2. ® INDICATE5 POINT LOAD SUPPORTED BY 5TRUGT P05T TO FND 3. ALL FOOTING5 TO BEAR ON UND15TURBED 501L 4. ALL WOOD IN CONTACT WITH CON-. TO BE PRESSURE TREATED 5. SOFFIT, VENT, d IN5ULATE CANTILEVERED AREA5 b. IN5TALL HOLD DOWN5 PER 5TRUGTURAL 1. STEP FOUNDATION PER 51TE CONDITIONS 8. 2,000 P.5.F. ASSUMED 501L BEARING CAPACITY 5HALL BE VERIFIED IN FIELD Q. ALL CONSTRUCTION TO COMPLY THE 2018 IRG AND ALL 5TATE AND LOCAL CODE5 10. LOCATE HOLD DOWN ANGHOR5 TO COORDINATE WITH 5HEARWALL END MEMBERS ABV II. ALL DIMENSIONS ARE FRAMING TO FRAMING AND BA5ED ON ACTUAL MATERIAL THIGKNE55 12. VERIFY ALL GUTTER AND DOWNSPOUT LOGATION5 ON 51TE AT TIME OF CONSTRUCTION 13. DOOR HEADER5 ® 6-8"" AFF UNO 14. WINDOW HEADER5 ® b'-8" AFF UNO 15. TRU55E5 PER MANUFACTURER 5PECIFICATION5 lb. WINDOW a DOOR HEADER5 TO BE bX8 DF#2 ® 5PAN5 b'-O" OR I F55 I'l. EXTERIOR WALL5 TO BE 2Xb 5TUD5 ® Ib" O.G., U.N.O. 15. PROVIDE FIRE BLOCKING ® ALL PLUMBING PENETRATIONS 19. IN5TALL 51MP50N GONG. TO WOOD HOLDOWNS 1 1/2" FROM CORNER5 S WINDOW ROUGH OPENING5 U.N.O., 5EE MANUFACTURER'S 5PEG5 20. 5MOKE/GO DETEGTOR5 5HALL BE IIOV INTERCONNECTED W/ BATTERY BACKUP, INSTALLED ON EACH FLOOR 4 IN ALL BEDROOM5 b IN EACH LOCATION WHERE THERE 15 A CEILING CHANGE GREATER THAN 24" z 0 � o Cif O c� 4.1 (� U O 3 O Q 3 U C� N w Q ry z Q ry W D- CL- U z R UB JunIJ8'12024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DRAWN BY: DATE: RK 5/20/2. REVISED BY: I DATE: RK I I I /2G/23 REVISED BY: I DATE: REVISED BY: I DATE: A2.0 BUILDING CODE NOTES ANCHORAGE OF APPLIANCES - APPLIACNES DESIGNED TO BE FIXED IN POSITION SHALL AP BE SECURELY FASTENED IN PLACE. SUPPORTS FOR APPLIANCES SHALL BE DESIGNED AND Ed CONSTRUCTED TO SUSTAIN VERTICICAL AND HORIZONTAL LOADS WITHIN THE STRESS LIMITATIONS SPECIFIED IN THE BUILDING CODE. IRC SECTION M 1307.2 EGRESS - ONE WINDOW OR DOOR IN THE BASEMENT AND IN EACH BEDROOM MUST MEET THESE REQUIEMENTS; -5.7 SOFT MIN. NET CLEAR OPEN AREA. 44" MAX EG SILL HEIGHT -20" MIN. CLEAR OPEN WIDTH, 24" MIN. CLEAR OPEN HEIGHT, IRC R31 0. GARAGE - FROM THE RESIDENCE AND ATTICS NOT LESS THAN 112" GYPSUM BOARD OR EQUIVALENT APPLIED TO THE GARAGE SIDE. STRUCTURES SUPPORTING FLOOR/CEILING ASSEMBLIES USED FOR SEPARATION REQUIRED BY THIS SECTION, NOT LESS THAN I /2" GYPSUM BOARD OR EQUIVALENT PER TABLE R302.G. GARAGE CEILINGS - FROM HABITABLE ROOMS ABOVE GARAGE NOT LESS THAN 5/6" TYPE GC X GYPSUM BOARD EQUIVALENT PER TABLE K302.G. GARAGE DOOR- 1-3/6" THICK (MIN.) SOLID CORE OR 20 MIN. FIRE RATED DOOR GD REQUIRED BETWEEN GARAGE AND DEWELLING W/ 20 MIN SELF -CLOSING OR AUTOMATIC - CLOSING DEVICE PER IRC 302.5. 1. HAND/GUARD RAIL - HAND RAILS SHALL BE PROVIDED ON NOT LESS THAN ONE SIDE OF EACH FLIGHT OF STAIRS W/ 4 OR MORE RISERS. AT 34"-38" ABOVE TREAD NOSING AND HR HANDRAIL GRASPING DIMENSION TO BE I 1/4"-2" MAX 4" OPENING BETWEEN INTERMEDIATE RAILS, PER IRC 3 1 1 .7.8 � IRC 3 1 1 .7.8. 1 � IRC R3 1 1.7.8.5 EXHAUST FANS - KITCHENS, BATHRROMS, LAUNDRY ROOMS MUST BE VENTED EF MECHANICALLY. ALL EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING, PER IRC M 1507.3 � M 1508. (FOR THIS PROJECT, ALL EXHAUST FANS TO BE I 10 CFM MIN.) UNLESS OTHERWISE NOTED, ALL VENTING THROUGH ROOF ROOF VENTILATION - UNVENTED ROOF ASSEMBLY PER R80G.5 ALL ATTIC SPACE TO BE RV WITHIN THERMAL ENVELOPE. AIR IMPERMEABLE INSULATION TO BE GLASS II VAPOR RETARDER OR HAVE CLASS II VAPOR RETARDER COATING IN CONACT WITH INSULATION. ASSEMBLY TO COMPLY WITH R80G.5. 1 * R80G.5.4. El R3 INSULATION - INSULATE ALL HOT 4� COLD WATER PIPES IN UNCONDITIONED AREAS WITH R-3 INSULATION. STAIRS - MIN. WIDTH = 30", MAX. 7 3/4" RISE, MIN. 10" RUN, MIN. 08" HEAD ROOM, PER IRC R3 1 1.7. SMOKE ALARMS AND CARBON MONOXIDE ALARMS - MUST BE POWERED BY CSD INERCONNECTED BUILDING WIRING AND HAVE BATTERY BACK-UP IN NEW CONSTRUCTION AND ADDTIONS. SD * CO ALARMS REQUIRED IN SLEEPING ROOMS, OUTSIDE BEDROOMS AND ON OTHER FLOORS, INCLUDING BASEMENTS. ANY ALARM MUST BE CLEARLY AUDIBLE IN ALL BEDROOMS, PER IRC R3 14.2.2, R3 14.3 $ R3 14.5. SAFETY GLASS - GLAZING IN OR ADJACENT TO DOORS (24"), GLAZING LESS THAN 18" F5SG FROM THE FLOOR, GLAZING ADJACENT TO STAIRS AND STAIR LANDINGS, GLAZING OF AN G INDIVIUDAL PANE LARGER THAN 95QFT, GLAZING IS MORE THAN 3G" ABOVE THE FLOOR, GLAZING ONE OR MORE WALKING SURFACES ARE W/IN 30 MEASURED HORIZONTALLY AND IN A STRAIGHT LINE PER IRC R308.4.3 WHOLE HOUSE VENTILATION - EACH DWELLING UNIT SHALL BE EQUIPPED WITH A WHOLE WHMV HOUSE VENITLATION SYSTEM WHICH SHALL BE CAPABLE OF PROVIDING THE VOLUME OF OUTDOOR AIR SPECIFIED IN TABLE M 1506.2. INTERMITTENTLY OPERATED, WHOLE HOUSE SYSTEMS SHALL HAVE THE CAPABILITY FOR CONTINUOUS OPERATION AND SHALL HAVE A MANUAL CONTROL AND AN AUTOMATIC CONTROL AND SHALL BE SIZED ACCORDINGLY PER IRC CHAPTER 15, M 1 507.3, M 1508.2 M 1508.3. FG FG - FIXED GLASS NOTE: ALL EXT. HEADERS ARE TO BE INSULATED TO K- 10 (MIN.) ALL DIMENSIONS ARE WALL STUD FACE UNLE55 NOTED OTHERWISE ALL INTERIOR WALLS TO BE 2X4 DIMENSION LUMBER W/ 1/2" GWB EA. 51DE, U.N.O. PLUMBING WALLS TO BE 2XG ROOF SYSTEM (UN -VENTED) STANDING SEAM METAL ROOFING OVER 1 5# FELT ROOFING PAPER OVER METAL FLA5HING5 OVER 1/2" PLYWOOD CDX SHEATHING OVER ROOF FRAMING PER STRUCTURAL PLANS WITH 3" CLOSED CELL, SPRAYED -IN INSULATION (K- 1 95) WITH 8.5" GATT INSULATION (K-30) OVER 5/8" GWB (AT INTERIOR SPACE) OR CLEAR OK `B' GRADE DF T*G SHEATHING @ O.H.'5 EXTERIOR WALL SYSTEM CEDAR I X8 LAP 51DING OVER M051TURE BARRIER; 30 LB. BUILDING PAPER, OVER STRUCTURAL SHEATHING, OVER 2XG STUDS @ I G" 0. C. WITH 2" FOAM INSULATION (K- 1 3) OVER FIBERGLASS BIB INSULATION K- 13 (R-2G AT HEATED SPACES OVER %2" GWB) UPPER FLOOR FRAMING FINISH FLOORING OVER 3/4" T*G PLYWOOD OVER FLOOR JOISTS PER STRUCTURAL PLANS W/ R-38 BATT INSULATION OVER 5/8" GWB MAIN FLOOR SYSTEM 4" CONCRETE SLAB WITH K- 10 RIGID INSULATION, CONT. (AT HEATED SPACES) OVER GMIL. VAPOR BARRIER GARAGE FLOOR SYSTEM 4" CONCRETE SLAB W/ #3 REBAR @ 24" O.C. EACH WAY OVER G MIL POLY VAPOR BARRIER OVER 4" COMPACTED GRANULAR FILL REFER TO STRUCTURAL SHEETS FOR BEAM SIZES AND 5TRUCTURAL DETAIL5 -ANY DISCREPANCIES BETWEEN STRUCTURAL SHEETS AND ARCHITECTURAL SHEETS, STRUCTURAL SHEETS SHALL GOVERN. WA5HINGTON STATE ENERGY CODE REQUIREMENTS: 1. ALL 51NK5 SHALL BE EQUIPPED WITH HOT WATER FLOW CONTROL DEVICES LIMITING FLOW TO 0.5 GPM, WHEN ENERGY CREDIT 5A SELECTED. 2. EXTERIOR JOINTS AROUND WINDOWS, DOORS, WALL, AND ROOF PENETRATIONS SHALL BE SEALED, CAULKED, GA5KETED OR WEATHER-STRIPPED TO LIMIT AIR LEAKAGE. 3. VAPOR BARRIERS WITH A MINIMUM 1.0 PERM RATING SHALL BE INSTALLED ON THE WARM 51DE OF INSULATED COMPONENTS. 4. CONTROLLED INDOOR MECHANICAL VENTILATION SYSTEMS WITH FRESH AIR SUPPLY SHALL BE INSTALLED IN ALL HABITABLE ROOMS. 5. HVAC SYSTEMS SHALL BE 51ZED NO GREATER THAN 150 % OF THE HEATING AND COOLING DE51GN LOADS. MIN. OUTDOOR AIR QUANTITIES SHALL BE PROVIDED PER W5EC. G. WHERE PRIMARY HEATING SYSTEM 15 FORCED AIR FURNACE, A PROGRAMMABLE THERMOSTAT SHALL BE INSTALLED CAPABLE OF, AT MINIMUM, A 5-2 PROGRAMMABLE SCHEDULE * BE CAPABLE OF AT LEAST 2 SETBACK PERIODS PER DAY, PER R403. 1 . 1 7. A MINIMUM OF 90% OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH -EFFICACY LAM P5 . 19'-2" EXISTING CONCRETE PATIO AREA 26'-0" 45' - 6 1 /2" — NEW UPPER FLOOR ROOF OVERHANG r----------------------------------------------�---- ----� EXISTING ROOF OVERHANG 3'-91/2" 3'-10" 4'-0" 3'-10" 3'-9— — — — — — — — — — — — — — — i EXISTING BEAM AND POSTS SUPPORTING EXISTING ROOF 8'-7" 8'-9" 8'-7" ol ol -LIGHT GRAY LINES REPRESENT 26' - o" NEW DECK ABOVE MAIN FLOOR. -DEPTH OF SECOND FLOOR DECK=7'-9', 202 SQFT OF NEW SPACE -NEW 2ND FLOOR HEATED LIVING SPACE IN ADDITION TO EXISTING _ I, SECOND FLOOR AREA. -279 SQFT OF NEW AREA N TV ROOM -LIGHT GRAY AREA 15 EXISTING 2 N D FLOOR FOOTPRINT ABOVE MAIN FLOOR. -534 SQFT OF EXISTING SPACE FIREPLACE M 9'-0" LIVING ROOM N 5' - 6 1 /2" ti I 5'-6" FRIDGE DOUBLE 0 r KITCHEN D/W M/W ISLAND L �II t--------------------- I ENTRY 5'-7" � 10'-2" N O 7'-1" DINING ROOM STORAGE 4'-4" _ OFFICE 12'-0" N 1 4'-3" r 3'-9" 3'-11" 3'-91/2" 3'-11" 3'-91/2" i401 8 8 I I L---- _---------- _-------- __--------- _-------- __________ _____� I 19'-2" EXISTING MAIN ELOOK WITH NEW SECOND ELOOK OUTLINE * NEW SECOND ELOOK KOOE OVERHANG SCALE: 1 /4" = 1 ' 0" NOTES: -ALL EXT. HEADERS ARE TO BE INSULATED TO K- 10 (MIN.) -ALL DIMENSIONS ARE WALL STUD FACE UNLE55 NOTED OTHERWISE -ALL INTERIOR WALLS TO BE 2X4 DIMEN51ON LUMBER W/ 1/2" GWB EA. SIDE, U.N.O. -PLUMBING WALLS TO BE 2XG 0 M no O 3'-4" w Q zo UP 3'-0" 3'-5" WH ol 1'-6" FURNACEol i9 0 0 0 3'-4" ol Al 5'-3" co NOTE: NEW IMPERVIOUS AREA, 19'-2"X2'=39 SQFT 14'-3" 3'-91/2" 3'-91/2" 3'-4" MASTER BEDROOM 3'-2" 1'-51 0 0 MASTER MASTER CLOSET BATH POWDER aOSET 10' - 10" BEDROOM # 2 GARAGE 14'-3" I I I 21' - 5" I00, I �---------------------------------------------------------------J cl z 0 � o C) 3 O Q 3 U M W 00 � N W Q O CV O W U @ z L1J o Q z o W `LJ W cz z ^ / J L.L Q W ry �' cn L O m U J z n� L� 0 0 J z Q C) W 0 0-- 0 R6U B Jun 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DRAWN BY: DATE: RK 5/20/23 REVISED BY: DATE: RK 1 /2G/23 REVISED BY: DATE: REVISED BY: DATE: A3.0 BUILDING CODE NOTES ANCHORAGE OF APPLIANCES - APPLIACNE5 DESIGNED TO BE FIXED IN POSITION SHALL AP BE SECURELY FASTENED IN PLACE. SUPPORTS FOR APPLIANCES SHALL BE DESIGNED AN Ed CONSTRUCTED TO SUSTAIN VERTICICAL AND HORIZONTAL LOADS WITHIN THE STRESS LIMITATIONS SPECIFIED IN THE BUILDING CODE. IRC SECTION M 1307.2 EGRESS - ONE WINDOW OR DOOR IN THE BASEMENT AND IN EACH BEDROOM MUST MEET THESE REQUIEMENTS; -5.7 SQFT MIN. NET CLEAR OPEN AREA. 44" MAX EG SILL HEIGHT -20 MIN. CLEAR OPEN WIDTH, 24 MIN. CLEAR OPEN HEIGHT, IRC R3 10. GARAGE - FROM THE RESIDENCE AND ATTICS NOT LESS THAN 112" GYPSUM BOARD OR EQUIVALENT APPLIED TO THE GARAGE SIDE. STRUCTURES SUPPORTING FLOOR/CEILING ASSEMBLIES USED FOR SEPARATION REQUIRED BY THIS SECTION, NOT LESS THAN 112" GYPSUM BOARD OR EQUIVALENT PER TABLE R302.G. GARAGE CEILINGS - FROM HABITABLE ROOMS ABOVE GARAGE NOT LESS THAN 5/8" TYPE GC X GYPSUM BOARD EQUIVALENT PER TABLE K302.G. GARAGE DOOR- 1 -3/8" THICK (MIN.) SOLID CORE OK 20 MIN. FIRE RATED DOOR GD REQUIRED BETWEEN GARAGE AND DEWELLING W/ 20 MIN SELF -CLOSING OR AUTOMATIC - CLOSING DEVICE PER IRC 302.5. 1. � niilllldllRlllllliiin�.� �i�IIIIIIIIIMIIGillllllllllllllllplw. dIItlIIIIIIpIIIIIVI!IIIIVIWI�s'i�l'u '�IIIIIIIIIIbIIIIC91Nlpllf ii01llli '�iIIMII�IIVIIIIIIIINII�IIIM"" -,�nomooiinv,. 20'- 0 1 /2" 4XG POS LAG BOL BOTTOM BEAM TC HAND/GUARD RAIL - HAND RAILS SHALL BE PROVIDED ON NOT LESS THAN ONE SIDE OF EACH FLIGHT OF STAIRS W/ 4 OR MORE RISERS. AT 34"-38" ABOVE TREAD NOSING AND FEATURES HR HANDRAIL GRASPING DIMENSION TO BE 1 1/4"-2" MAX 4" OPENING BETWEEN FR1 Variables speed INVERTER -driven com compressor p p r---- ------------------------------ I INTERMEDIATE RAILS, PER IRC 31 1 .7.6 * IRC 31 1 .7.6. 1 � IRC R3 1 1.7.6.5 • Built-in base pan heater I • Quiet outdoor unit operation as low as 54 dB(A) EXHAUST FANS - KITCHENS, BATHRROMS, LAUNDRY ROOMS MUST BE VENTED High-pressure protection -7 MECHANICALLY. ALL EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING, PER IRC Compressor thermal protection - M 1507.3 * M 1508. (FOR THIS PROJECT, ALL EXHAUST FANS TO BE 110 CFM MIN.) Compressor overcurrent detection UNLESS OTHERWISE NOTED, ALL VENTING THROUGH ROOF Fan motor overheating/voltage protection r • Hyper -heating performance offers 100% heating capacity at 5'F and 90% heating capacity at -13JF ROOF VENTILATION - UNVENTED ROOF ASSEMBLY PER R80G.5 ALL ATTIC SPACE TO BE RV Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life WITHIN THERMAL ENVELOPE. AIR IMPERMEABLE INSULATION TO BE BLA55 II VAPOR Rated for 2.000 hours spraying time perASTM B117 Standard RETARDER OR HAVE CLA55 II VAPOR RETARDER COATING IN CONACT WITH INSULATION. ASSEMBLY TO COMPLY WITH R80G.5. 1 � K80G.5.4. SEER2 19.0// 17251/15.5116.7H14A E E R2' 13.5 /111.751110-01 11.751110.0 ElR3HSPF2 R3 INSULATION - IN5ULATE ALL HOT * COLD WATER PIPES IN UNCONDITIONED AREAS (IV) 10.01/ 925 H 8.518.95 n 7.9 (Non -Ducted // Mix (Low -static) // Ducted WITH K-3 INSULATION. (Low -static) I Mix (High -static) // Ducted COP at 47'F= 4.24 // 4.04 // 3.8 1 3.971/ 3.7 (High -static)) COP at 17'F at Maximum Capacity 2.06 // 1.97 // 1.9 1 1.98// 1.9 COP at 5•F at Maximum Capacity' 1.95 // 1.82 // 1.751 1.85 // 1.75 El STAIRS - MIN. WIDTH = 30", MAX. 7 3/4" RISE, MIN. 10" RUN, MIN. 08" HEAD ROOM, ENERGY STAR" Certified Yes I/ Yes H No I Yes // No PER IRC K3 1 1.7. A A A A A A A A A A A SMOKE ALARMS AND CARBON MONOXIDE ALARMS - MUST BE POWERED BY CSD INERCONNECTED BUILDING WIRING AND HAVE BATTERY BACK-UP IN NEW CONSTRUCTION AND ADDTIONS. SD * CO ALARMS REQUIRED IN SLEEPING ROOMS, OUTSIDE BEDROOMS AND ON OTHER FLOORS, INCLUDING BASEMENTS. ANY ALARM MUST BE CLEARLY AUDIBLE IN ALL BEDROOMS, PER IRC R3 14.2.2, K3 14.3 * R3 14.5. SAFETY GLASS - GLAZING IN OR ADJACENT TO DOORS (24"), GLAZING LESS THAN 1 8" SG FROM THE FLOOR, GLAZING ADJACENT TO STAIRS AND STAIR LANDINGS, GLAZING OF AN F INDIVIUDAL PANE LARGER THAN 95QFT, GLAZING IS MORE THAN 30 ABOVE THE FLOOR, GLAZING ONE OR MORE WALKING SURFACES ARE MIN 30 MEASURED HORIZONTALLY AND IN A STRAIGHT LINE PER IRC R308.4.3 WHOLE HOUSE VENTILATION - EACH DWELLING UNIT SHALL BE EQUIPPED WITH A WHOLE WHMV HOUSE VENITLATION SYSTEM WHICH SHALL BE CAPABLE OF PROVIDING THE VOLUME OF OUTDOOR AIR SPECIFIED IN TABLE M 1508.2. INTERMITTENTLY OPERATED, WHOLE HOUSE SYSTEMS SHALL HAVE THE CAPABILITY FOR CONTINUOUS OPERATION AND SHALL HAVE A MANUAL CONTROL AND AN AUTOMATIC CONTROL AND SHALL BE SIZED ACCORDINGLY PER IRC CHAPTER 15, M 1 507.3, M 1508.2 * M 1508.3. FG FG - FIXED GLASS NOTE: ALL EXT. HEADERS ARE TO BE INSULATED TO K-10 (MIN.) ALL DIMENSIONS AKE WALL STUD FACE UNLESS NOTED OTHERWISE ALL INTERIOR WALLS TO BE 2X4 DIMENSION LUMBER W/ %2" GWB EA. SIDE, U.N.O. PLUMBING WALLS TO BE 2XG ROOF SYSTEM (UN -VENTED) STANDING SEAM METAL ROOFING OVER 1 5# FELT ROOFING PAPER OVER METAL FLASHINGS OVER I/2" PLYWOOD CDX SHEATHING OVER ROOF FRAMING PER STRUCTURAL PLANS WITH 3" CLOSED CELL, SPRAYED -IN INSULATION (K-1 95) WITH 8.5" BATT INSULATION (K-30) OVER 5/8" GWB (AT INTERIOR SPACE) OR CLEAR OR `B' GRADE DF T*G SHEATHING @ O.H.'S EXTERIOR WALL SYSTEM CEDAR I X8 LAP SIDING OVER MOSITUKE BARRIER; 30 LB. BUILDING PAPER, OVER STRUCTURAL SHEATHING, OVER 2XG STUDS @ I G" O.C. WITH 2" FOAM INSULATION (K-13) OVER FIBERGLASS BIB INSULATION K- 13 (R-2G AT HEATED SPACES OVER %2" GWB) UPPER FLOOR FRAMING FINISH FLOORING OVER 3/4" TAG PLYWOOD OVER FLOOR JOISTS PER STRUCTURAL PLANS W/ R-38 BATT INSULATION OVER 5/8" GWB MAIN FLOOK SYSTEM 4" CONCRETE SLAB WITH K-1 0 RIGID INSULATION, CONT. (AT HEATED SPACES) OVER GMIL. VAPOR BARRIER GARAGE FLOOR SYSTEM 4" CONCRETE SLAB W/ #3 REBAR @ 24" O.C. EACH WAY OVER G MIL POLY VAPOR BARRIER OVER 4" COMPACTED GRANULAR FILL WASHINGTON STATE ENERGY CODE REQUIREMENTS: 1. ALL SINKS SHALL BE EQUIPPED WITH HOT WATER FLOW CONTROL DEVICES LIMITING FLOW TO 0.5 GPM, WHEN ENERGY CREDIT 5A SELECTED. 2. EXTERIOR JOINTS AROUND WINDOWS, DOORS, WALL, AND ROOF PENETRATIONS SHALL BE SEALED, CAULKED, GASKETED OR WEATHEK-STRIPPED TO LIMIT AIR LEAKAGE. 3. VAPOR BARRIERS WITH A MINIMUM 1.0 PERM RATING SHALL BE INSTALLED ON THE WARM SIDE OF INSULATED COMPONENTS. 4. CONTROLLED INDOOR MECHANICAL VENTILATION SYSTEMS WITH FKESH AIR SUPPLY SHALL BE INSTALLED IN ALL HABITABLE ROOMS. 5. HVAC SYSTEMS SHALL BE SIZED NO GREATER THAN 150 % OF THE HEATING AND COOLING DESIGN LOADS. MIN. OUTDOOR AIR QUANTITIES SHALL BE PROVIDED PER WSEC. G. WHERE PRIMARY HEATING SYSTEM IS FORCED AIR FURNACE, A PROGRAMMABLE THERMOSTAT SHALL BE INSTALLED CAPABLE OF, AT MINIMUM, A 5-2 PROGRAMMABLE SCHEDULE * BE CAPABLE OF AT LEAST 2 SETBACK PERIODS PER DAY, PER R403. 1 . 1 7. A MINIMUM OF 90% OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH -EFFICACY LAMPS. REFER TO STRUCTURAL SHEETS FOR BEAM SIZES AND STRUCTURAL DETAILS -ANY DISCREPANCIES BETWEEN STRUCTURAL SHEETS AND ARCHITECTURAL SHEETS, t STRUCTURAL SHEETS SHALL GOVERN. FLOOR LINE BELOW mnTF1:, • -ALL EXT. HEADERS ARE TO BE INSULATED TO K- 10 (MIN.) -ALL DIMENSIONS ARE WALL STUD FACE UNLESS NOTED OTHERWISE -ALL INTERIOR WALLS TO BE 2X4 DIMENSION LUMBER W/ l/2" GWB EA. SIDE, U.N.O. -PLUMBING WALLS TO BE 2XG 20'- 1" SCALE: 1 /4'' = 1 ' 0" I , I , I I � I I I � I I I � I I NOTE: I -ALL EXTERIOR WALLS ON NEW UPPER FLOOR LEVEL TO BE PERSCRIPTIVE SHEAR WALLS -ALL EXTERIOR WALLS ON NEW UPPER LEVEL TO BE 2XG STUDS @ I G" O.C. W/ 112" CDX PLYWOOD NAILED @ G" O.C. AT EDGES * 1 2" O.C. IN THE FIELD. -PROVIDE CONTINIOUS BEARING FROM ALL ENDS OF BEAMS TO FOUNDATION, FOR CONTINIOUS SUPPORT I , I , I , I I � I I 1R-9" z O H o O 0�8 zQ� z MW00 r- N Q O N O LLJ o U < z LLJ o Q z V J S LL.1 w ry z Cl/ Q LL1 LLJ O cm O O J LL R/ 11 1 D_ D_ D Q LU O O REgUB Jun 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DRAWN BY: DATE: RK 5/20/23 REVISED BY: I DATE: RK I I1/2G/23 REVISED BY: I DATE: REVISED BY: I DATE: 22' - 4" A3. 1 26'-0" -91 5IMP50N CBGG GALVANIZED POST BASE TO SUPPORT GXG POST 1'-0" 12" SAUNA TUBE 51MP50N CBGG POST BASE BRACKET G d -GRADE 12" x 12" CONCRETE 71 ° b COLUMN W/ (4) #4 VERTICAL REBAR 30" X 30" X 12" CONCRETE FOOTING W/ ,• - - ° cd ° ,-d d' a _a a - b ° (3) #4 REBAR EACH WAY 0'-6" 1'-6" 1 0'-6" TYPICAL NEW POST FOOTING, 2 REQUIRED SCALE: 1 112'' = 1 1 0" fOU N DATI ON PLAN SCALE: 114'' = 1 ' 0" 0 FA EXISTING CONCRETE PATIO TO REMAIN THE SAME, 2G'X25' 0 in N -EXISTING G"XG" POST, TYP. -REPLACE EXISTING FOOTINGS WITH 3'X3'X 12" CONCRETE FOOTING -PROVIDE (5) #4 REBAR EACH WAY -USE CBGXG 51MP50N POST BRACKET -BOTTOM OF FOOTING 1 8" BELOW TOP OF CONCRETE r— — — — — — — — — — — — 1 i 1 1 NJ 1 i 1 1 J EXISTING MAIN FLOOR TO REMAIN THE SAME 0 0 N -8"X 1 5" CONCRETE FOOTING TO SUPPORT UPPER FLOOR ADDITION -VERIFY EXISTING FOOTITING SIZE W z F--I U Q 0 U� 8 Z z MW00 -- N Q RESUB Jun 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DRAWN BY: DATE: RK 5/20/23 REVISED BY: DATE: RK I1/2G/23 REVISED BY: I DATE: REVISED BY: I DATE: I A3.2 25' - 11 " 4X 12 BEAM JOIST HANGER SCALE: 1 1 /2'' = 1 ' 0" 0) 19'-2" T v T 0 REFER TO STRUCTURAL o SHEETS FOR BEAM SIZES M AND STRUCTURAL DETAILS -ANY DISCREPANCIES BETWEEN STRUCTURAL SHEETS AND ARCHITECTURAL M SHEETS, STRUCTURAL SHEETS SHALL GOVERN. E IAA M I N G PLAN SCALE: 1 /4'' = I ' 0" WAWA EXISTING BEAM * POSTS TO REMAIN SISTER NEW 2X 10 FLOOR JOISTS @ I G" O.C. TO EX15TING FLOOR JOISTS FOR NEW DECK II EXISTING HEADER TO REMAI I 15'-2" NEW 2X 10 RIM J015T EX15TING HEADER TO REMAI EX15TING 2X 10 FLOOR JOISTS @ I G" O.C. PROPOSED NEW UPPER FLOOR OUT5IDE WALL LINE PROVIDE 50LID BLOCKING BETWEEN EXISTING * NEW FLOOR JOISTS OVER EX15TING LOWER WALL/HEADER EX15TING UPPER FLOOR OUT5IDE WALL LINE 11'-3" EXISTING 2X 10 FLOOR JOISTS @ I G" O.C. EX15TING BEAM TO REMAIN EX15TING BEAM TO REMAIN EX15TING HEADER TO REMAIN --- -- -- --- -- -- — -- ------ -- ------ -- -- ------ — ---- - - - - -T I-■ 3'-0" 3'-4" UP EX15TING HE�DER5 TO REMAIN ...6. 1 . EX15TING BEPM TO REMAIN 14'-3" —SISTER NEW 2X I 0 FLOOR JOISTS @ I G" O.C. TO EX15TING FLOOR JOISTS FOR NEW UPPER FLOOR 2' OVER HANG —PROVIDE (2) 51MF50N 5D 3" SCREWS @ I G" O.C. TO CONNECT THE NEW 8' LONG FLOOR JOISTS. 0 0 2 z 0 � o U Q 0 .� U� 8 Z z MW00 W r� O CV O LLJ o U < z W o Q z O V J C) W w li W W/ O cm RESUB Jun 18 2024 CV GARAGE CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT °' DRAWN BY: DATE: RK 5/20/23 REVISED BY: DATE: RK I1/2G/23 REVISED BY: DATE: REVISED BY: I DATE: I 21'-5" � A3.3 GUI 0 Mr- IAL Vr-NI SIKII'S 2'-6" TYFICAL IAAETER OVERHANG SCALE 1 1 /2" = I ' 0" 5/8" CDX PLYWOOD W/ ROOF CLIPS @ EDGES ROOF OUTRIGGERS SCALE: 1 1 /2'' = 1 ' 0" 2X CEDAR BLOCK 5/6" CDX PLYWOOD W/ ROOF CLIPS AT JOINTS OF PLYWOOD I XG CEDAR FASCIA 2X 12 CEDAR FASCIA 2 I /2" X 8' CONTINOU5 METAL VENT STRIP LOWER ISO O E DETAIL SCALE: 1 1 /2" = 1 ' 0" EDAR 2X 12 RAFTERS @ 24" O.C. 1 /2" X 5 1 /2" TtG WOOD SOFFIT REFER TO STRUCTURAL SHEETS FOR BEAM SIZES AND STRUCTURAL DETAILS -ANY DISCREPANCIES BETWEEN STRUCTURAL SHEETS AND ARCHITECTURAL SHEETS, STRUCTURAL SHEETS SHALL GOVERN. VENT SPACE F P SC M w N z 0 � o U Q 0 .� U� 8 Z z MW00 -- N W Q O CV O W o U < z lW o Q z _ O o W w ry z LL Q W I— _ O cm RESUB Jun 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DRAWN BY: DATE: RK 5/20/23 REVISED BY: DATE: RK I1/2G/23 REVISED BY: I DATE: REVISED BY: I DATE: A3.4 Max Height Allowed, 25' 24'-2" z 0 � o U Q 0 .� U� '�8 Z z MW00 w Q -3" OF CLOSED CELL RIGID FOAM INSULATION W/ FIBERGLASS BATTS. -NO VENTILATION REQUIRED PROVIDE FIBERGLASS 4' - 0" T - 9" 16' - 0" 2' - 0" INSULATION IN ALL OVERHANGS, NO VENTING 51/8"XI 2" GILD HEADER 18' 6" Height REQUIRED Restriction 171-811 1 /4" / 1 2" ROOF SLOPE Inside peak of roof - 11/2"X4" FRAMING ANCORED TO i� /ice \ 15' - 11" c\j O TOP OF BEAM W/ 2 1 /2" GALVANIZED W CARRIAGE BOLTS, (CARRIAGE HEAD �� / PROPOSED UPPER FLOOR \ \ ( Q TO FACE DOWN). / `J -PROVIDE (2) 51MP50N A35 STRONG PROPOSED UPPER z TIES @ EACH RAFTER TO FRAMING FLOOR DECK 7 PLATE - /j 00 I EXISTING SLOPED ROOF iv 17 PROPOSED NEW EXTERIOR ti C) N WALL FOR SECOND FLOOR a, °c_' .v, U--, W BEDROOM ` // / I I 12'-0" x w FACE MOUNTED 3' HIGH RAILING W/ // w p RAILING UPRIGHTS @ 3 1 5/ 1 G" MAX Q OPENING NEW SGD, PROVIDE SAFETY GLASS EXISTING OUTSIDE WALLS OF SECOND FLOOR � W _ z t Upper Floor bo PROPOSED NEW EXTERIOR WALL FOR SECOND FLOOR, MAIN ROOM ih bo 8' - 81v LLJ LL O ° 0 2'-0" Y CD z W m o PROVIDE URATHANE WATERPROOF - ao COATING OVER i o DECK, SLOPE 1 /8"/ 1 ' ' 1 00 EXISTING KITCHEN / DINING ROOM i� HALLWAY EXISTING OFFICE TO REMAIN THE SAME EXISTING GARAGE TO REMAIN THE SAME L/ Main Floor 0 0'-011 L el EXISTING CRAWL SPACE UNDER MAIN FLOOR 7Ground A-� go -01-1011 NEW FOOTING, SEE FOUNDATION PLAN ON SHEET A3.2. TWO REQUIRED CROSS SECTION Of PROPOSED ROOF REMODEL FOR A COVERED PATIO AREA SCALE: 3/8'' = 1 ' 0" Pu5T BLOCKING PER LAGS - �- - 4 t� �-- FAST A M rjU N T BRACKET TYPICAL DECK SOFT IT STRUCTURAL DETAIL TO MEET LATERAL SUPPORT REQU I REM ENTS FOR DECK RAILING NTS z 0 U LL n n 0 R/ U RESUB Jun 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DRAWN BY: DATE: RK 5/20/23 REVISED BY: DATE: RK 8/5/23 REVISED BY: DATE: RK 8/7/23 REVISED BY: DATE: RK 11/2G/23 A4.0 NORTH ELEVATION SCALE: 1 /4" = I '-0" SOUTH ELEVATION SCALE: 1 /4" = I '-0" ROOF SYSTEM (UN -VENTED) STANDING SEAM METAL ROOFING OVER 1 5# FELT ROOFING PAPER OVER METAL FLA5HING5 OVER i/2" PLYWOOD CDX SHEATHING OVER ROOF FRAMING PER STRUCTURAL PLANS WITH 3" CL05ED CELL, SPRAYED -IN INSULATION (R- 1 95) WITH 8.5" BATT INSULATION (R-30) OVER 5/6" GWB (AT INTERIOR SPACE) OR CLEAR OR `B' GRADE DF T*G SHEATHING @ 0.H.'5 EXTERIOR WALL SYSTEM CEDAR I X8 LAP 51DING OVER M051TURE BARRIER; 30 LB. BUILDING PAPER, OVER STRUCTURAL SHEATHING, OVER 2XG STUDS @ I G" O.0 WITH 2" FOAM INSULATION (R- 1 3) OVER FIBERGLASS BIB INSULATION R- 13 (R-2G AT HEATED SPACES OVER i/2" GWB) Max Height Allowed, 25 24' - 2" 18' 6" Height Restriction 17, - 8" Inside peak of roof 15- 11" Upper Floor 8' - 811 Main Floor o'-o" 18' 6" Height Restriction 17'-8" nside peak of roof 15' - 11" V z O � o O ¢ � 3 O Q 3 U zQm c Z M W 00 N W Q C W J z 0 Q Upper Floor LLl 8'-8" W Main Floor � 0'-0" V Z O z UPPER FLOOR FRAMING FINISH FLOORING OVER 3/4" T*G PLYWOOD OVER FLOOR JOISTS PER STRUCTURAL PLANS W/ R-38 BATT INSULATION OVER 5/6" GWB MAIN FLOOR SYSTEM 4" CONCRETE SLAB WITH R-10 RIGID INSULATION, CONT. (AT HEATED SPACES) OVER GMIL. VAPOR BARRIER GARAGE FLOOR SYSTEM 4" CONCRETE SLAB W/ #3 REBAR @ 24" O.C. EACH WAY OVER G MIL POLY VAPOR BARRIER OVER 4" COMPACTED GRANULAR FILL RESUB Jun 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DRAWN BY: DATE: RK 5/20/23 REVISED BY: DATE: RK 8/5/23 REVISED BY: DATE: KK 8/7/23 REVISED BY: DATE: RK 1112GI23 A5.0 EAST ELEVATION SCALE: 1 /4" = 1 '-0'I CID \ EO WEST ELEVATION SCALE: 1 /4'' = 1 '-0" ROOF SYSTEM (UN -VENTED) STANDING SEAM METAL ROOFING OVER 1 5# FELT ROOFING PAPER OVER METAL FLASH I NGS OVER %2" PLYWOOD CDX SHEATHING OVER ROOF FRAMING PER STRUCTURAL PLANS WITH 3" CLOSED CELL, SPRAYED -IN INSULATION (R- 1 95) WITH 8.5" BATT INSULATION (R-30) OVER 5/8" GW5 (AT INTERIOR SPACE) OR CLEAR OR `B' GRADE DF T*G SHEATHING @ O.H.'5 EXTERIOR WALL SYSTEM CEDAR I X8 LAP SIDING OVER M051TUKE BARRIER; 30 LB. BUILDING PAPER, OVER STRUCTURAL SHEATHING, OVER 2XG STUDS @ I G" O.0 WITH 2" FOAM INSULATION (R-1 3) OVER FIBERGLASS BIB INSULATION R- 13 (R-2G AT HEATED SPACES OVER i/2" GW5) 18' 6" Height Restriction 17'-8" Inside peak of roof 15' - 11" Upper Floor 8'-8„ Main Floor o'-o° 18' 6" Height Restriction � 17'-8" � Inside peak of roof n 15' - 11" Upper Floor 8' - 811 Main Floor 0'-0" Ground Level -0' - 1 o" �I UPPER FLOOR FRAM I NG FINISH FLOORING OVER 3/4" TAG PLYWOOD OVER FLOOR JOISTS PER STRUCTURAL PLANS W/ R-38 BATT INSULATION OVER 5/8" GWB MAIN FLOOR SYSTEM 4" CONCRETE SLAB WITH R-10 RIGID INSULATION, CONT. (AT HEATED SPACES) OVER GMIL. VAPOR BARRIER GARAGE FLOOR SYSTEM 4" CONCRETE SLAB W/ #3 REBAR @ 24" O.C. EACH WAY OVER G MIL POLY VAPOR BARRIER OVER 4" COMPACTED GRANULAR FILL z 0 � o v Q H U � O ¢ � 3 O Q 3 U Z M W 00 N w Q C W J M RESUB Jun 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DRAWN BY: DATE: RK 5/20/23 REVISED BY: DATE: RK 8/5/23 REVISED BY: DATE: KK 8/7/23 REVISED BY: DATE: RK 1112GI23 A5. I