REV1 REVIEWED BLD RESUB1 BLD2021-0811+Structural_Calculations+9.11.2024_1.56.25_PM+4494364E
E S G D E S I G N Eli Grassley, P.E.
REVISION L ..............................................�
REVIEWED
RESU B BLD2021-0811 BY
Sep 11 2024 CITY OF EDMONDS
CITY OF EDMONDS
DEVELOPMENTSERVICES
DEPARTMENTMENT = BUILDING DEPARTMENT :
...............................................
5TRUCTURAL CALCULATION5
FOR
EDMONDS HOMES -UNIT 3
Edmonds, AA
PREPARED BY:
ESG Of51GN, PLLG
July Z4, ZOZ4
ENGINEERED • STRUCTURES • GLOBAL • DESIGN
7-24 2024
%R 4IS1 ::
AL E
ESG Design, PLLC - 12540 202nd PL SE, Issaquah, WA 98027 1 engineer@esg-design.com 1 206-660-2044
ESGDESIGN
GRAVITY DESIGN
Eli Grassley, P.E.
ENGINEERED • STRUCTURES • GLOBAL • DESIGN I Edmonds — Lot 3
t
MIN
(2)2x6
(2)2
MIN
ESGDESIGN
ROOF FRAMING 5Ct1EME
Eli Grassley, P.E.
HF#2 P05T
IMMER 5TUD
RIMMER STUD
{NF#2 P05T
ENGINEERED STRUCTURES GLOBAL DESIGN Edmonds — Lot 3
a FORTE W GB MEMBER REPORT
Unit 3 Roof, Roof Rafter
1 piece(s) 11 7/8" THO 360 @ 24" OC
PASSED
+ +
G 0
r
IL �
l
1
21
C
9
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
864 @ 2 1/2"
1731 (3.50")
Passed (50%)
1.15
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
841 @ 3 1/2"
1961
Passed (43%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
4486 @ 10' 9 1/2"
7107
Passed (63%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.593 @ W 9 1/2"
1.062
Passed (L/430)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.950 @ 10' 9 1/2"
1.416
Passed (L/268)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Beveled Plate - HF
3.50"
3.50"
1.75"
325
540
864
Blocking
2 - Beveled Plate - HF
3.50"
3.50"
1.75"
325
540
864
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
4' 4" o/c
Bottom Edge (Lu)
21' 8" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
-Maximum allowable bracing intervals based on applied load.
-Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions.
Vertical Load
Location
Spacing
Dead
(0.90)
Snow
(1.15)
Comments
1 - Uniform (PSF)
0 to 21' 7"
24"
15.0
25.0
Roof Load
Member Length : 21' 8 7/8"
System : Roof
Member Type : Joist
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Member Pitch : 1/12
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/21/2024 8:59:52 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
a FORTE W GB MEMBER REPORT
Unit 3 Roof, Beam BI
1 piece(s) 3 1/2" x 10 1/2" 24F-V4 DF Glulam
PASSED
10'
C
i
r
0
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
4492 @ 2"
5206 (3.50")
Passed (86%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
3502 @ 1' 2"
7466
Passed (47%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
11149 @ 5' 3 1/2"
14792
Passed (75%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.215 @ 5' 3 1/2"
0.512
Passed (L/573)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.347 @ 5' 3 1/2"
0.683
Passed (L/355)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: ILL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 10' 3".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Stud wall - SPF
3.50"
3.50"
3.02"
1714
2778
4492
Blocking
2 - Stud wall - SPF
3.50"
3.50"
3.02"
1714
2778
4492
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
10' 7" o/c
Bottom Edge (Lu)
10' 7" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary
(0.90)
(1.15)
Comments
Width
0 - Self Weight (PLF)
0 to 10' 7"
N/A
8.9
1 - Uniform (PSF)
0 to 10' 7" (Front)
21'
15.0
25.0
Roof
• Side loads are assumed to not induce cross -grain tension.
Member Length : 10' 7"
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Member Pitch : 0/12
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/21/2024 9:01:35 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
.I FORTE W E B MEMBER REPORT
Unit 3 Roof, Beam B1 Exterior wall post
3 piece(s) 2 x 6 HF No.2
PASSED
Drawing is Conceptual
Wall Height: 8' Member Height: 7' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
20
50
Passed (41%)
Compression (Ibs)
4492
11716
Passed (38%)
1.15
1.0 D + 1.0 S
Plate Bearing (Ibs)
4492
10519
Passed (43%)
--
1.0 D + 1.0 S
Lateral Reaction (Ibs)
58
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
51
3960
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
111 @ mid -span
3315
Passed (3%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.03 @ mid -span
0.76
Passed (L/2993)
1.0 D + 0.45 W + 0.75 L + 0.75 S
Bending/Compression
0.32
1
Passed (32%)
1.15
1.0 D + 1.0 S
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• The column stability factor (Kf = 0.6) applied to this design assumes nailed built-up columns per NDS section 15.3.3. For Weyerhaeuser ELP products refer to
the U.S. Wall Guide for multiple -member connection requirements.
Supports
Type
Material
Top
Dbl 2X
Spruce -Pine -Fir
Base
2X
Spruce -Pine -Fir
Max Unbraced Length Comments
177 1/2"
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type : Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Load
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
1 - Point (lb)
N/A
1714
2778
Beam BI
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.5
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33% Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/21/2024 11:28:25 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
ESG Design
www.esg-design.com
BeamChek v2023 licensed to: Markiian Trembach Reg # 5508-68673
Edmonds x4 - Lot 3 Roof Beam B2
Prepared by: MT Date: 6/21/24
Selection W 12x 19 50 ksi Wide Flange Steel Lateral Support: Lc = 3.6 ft max.
Conditions Actual Size is 4 x 12-1/8 in.
Min Bearing Length R1= 0.8 in. R2= 0.8 in. (1.0) DL Defl= 0.38 in Recom Camber= 0.57 in
Data
Attributes
Critical
Status
Ratio
Values
Adiustments
Beam Span
20.9 ft
Reaction 1 LL
5486 # Reaction 2 LL 5486 #
Beam Wt per ft
19.0 #
Reaction 1 TL
8977 # Reaction 2 TL 8977 #
Bm Wt Included
397 #
Maximum V
8977 #
Max Moment
46902 '#
Max V (Reduced)
N/A
TL Max Defl
L / 240
TL Actual Defl
L / 257
LL Max Defl
L / 360
LL Actual Defl
L / 420
Section (in3)
Shear (in2)
TL Defl (in)
LL Defl
21.30
2.86
0.98
0.60
17.06
0.45
1.05
0.70
OK
OK
OK
OK
80%
16%
93%
86%
Fb (psi)
Fv (psi) E (psi x mil)
Ref. Value Fy
Adjusted Values
50000
33000
50000 29.0
20000 29.0
YP Factor, Lc
0.66
0.40
Loads Uniform LL: 525 Uniform TL: 840 = A
Uniform Load A
0
R1 = 8977 R2 = 8977
SPAN = 20.9 FT
Uniform and partial uniform loads are Ibs per lineal ft.
.I FORTE W E B MEMBER REPORT
Unit 3 Roof, Beams BI-B2 post
1 piece(s) 5 1/4" x 5 1/4" 1.8E Parallam@ PSL
PASSED
Drawing is Conceptual
Wall Height: 8' Member Height: 7' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
17
50
Passed (35%)
Compression (Ibs)
13026
55383
Passed (24%)
1.15
1.0 D + 1.0 S
Plate Bearing (Ibs)
13026
17227
Passed (76%)
--
1.0 D + 1.0 S
Lateral Reaction (Ibs)
58
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
52
6762
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
111 @ mid -span
8812
Passed (1%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.05 @ mid -span
0.76
Passed (L/1703)
1.0 D + 1.0 S
Bending/Compression
0.23
1
Passed (23%)
1.15
1.0 D + 1.0 S
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• Bearing shall be on a metal plate or strap, or on other equivalently durable, rigid, homogeneous material with sufficient stiffness to distribute applied load.
• This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation.
Supports
Type
Material
Top
Dbl 2X
Douglas Fir -Larch
Base
2X
Douglas Fir -Larch
Max Unbraced Length Comments
7' 7 1/2"
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type : Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Loads
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
1 - Point (lb)
N/A
1714
2778
Beam BI
2 - Point (lb)
N/A
3336
5198
Beam B2
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.5
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/21/2024 10:12:29 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
ESG Design
www.esg-design.com
BeamChek v2023 licensed to: Markiian Trembach Reg # 5508-68673
Edmonds x4 - Lot 3 Roof Beam B3
Prepared by: MT Date: 6/21/24
Selection W 12x 14 50 ksi Wide Flange Steel Lateral Support: Lc = 2.5 ft max.
Conditions Actual Size is 4 x 11-7/8 in.
Min Bearing Length R1= 0.7 in. R2= 0.7 in. (1.0) DL Defl= 0.28 in Recom Camber= 0.42 in
Data
Attributes
Critical
Status
Ratio
Values
Adiustments
Beam Span
17.66 ft
Reaction 1 LL
4636 # Reaction 2 LL 4636 #
Beam Wt per ft
14.0 #
Reaction 1 TL
7541 # Reaction 2 TL 7541 #
Bm Wt Included
247 #
Maximum V
7541 #
Max Moment
33293 '#
Max V (Reduced)
N/A
TL Max Defl
L / 240
TL Actual Defl
L / 292
LL Max Defl
L / 360
LL Actual Defl
L / 475
Section (in3)
Shear (in2)
TL Defl (in)
LL Defl
14.90
2.38
0.73
0.45
12.11
0.38
0.88
0.59
OK
OK
OK
OK
81%
16%
82%
76%
Fb (psi)
Fv (psi) E (psi x mil)
Ref. Value Fy
Adjusted Values
50000
33000
50000 29.0
20000 29.0
YP Factor, Lc
0.66
0.40
Loads Uniform LL: 525 Uniform TL: 840 = A
Uniform Load A
R1 = 7541 R2 = 7541
SPAN = 17.66 FT
Uniform and partial uniform loads are Ibs per lineal ft.
.I FORTE W E B MEMBER REPORT
Unit 3 Roof, Beams B2-B3 post
1 piece(s) 5 1/4" x 5 1/4" 1.8E Parallam@ PSL
PASSED
Drawing is Conceptual
Wall Height: 8' Member Height: 7' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
17
50
Passed (35%)
Compression (Ibs)
15870
55383
Passed (29%)
1.15
1.0 D + 1.0 S
Plate Bearing (Ibs)
15870
17227
Passed (92%)
--
1.0 D + 1.0 S
Lateral Reaction (Ibs)
58
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
52
6762
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
111 @ mid -span
8812
Passed (1%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.07 @ mid -span
0.76
Passed (L/1398)
1.0 D + 1.0 S
Bending/Compression
0.31
1
Passed (31%)
1.15
1.0 D + 1.0 S
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• Bearing shall be on a metal plate or strap, or on other equivalently durable, rigid, homogeneous material with sufficient stiffness to distribute applied load.
• This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation.
Supports
Type
Material
Top
Dbl 2X
Douglas Fir -Larch
Base
2X
Douglas Fir -Larch
Max Unbraced Length Comments
7' 7 1/2"
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type : Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Loads
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
1 - Point (lb)
N/A
3039
4791
Beam B2
2 - Point (lb)
N/A
3151
4889
Beam B3
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.5
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 7:30:23 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
.I FORTE W E B MEMBER REPORT
Unit 3 Roof, Beam B3 Exterior wall post
3 piece(s) 2 x 6 HF No.2
PASSED
Drawing is Conceptual
Wall Height: 8' Member Height: 7' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
20
50
Passed (41%)
Compression (Ibs)
7830
11716
Passed (67%)
1.15
1.0 D + 1.0 S
Plate Bearing (Ibs)
7830
15469
Passed (51%)
1.0 D + 1.0 S
Lateral Reaction (Ibs)
58
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
51
3960
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
111 @ mid -span
3315
Passed (3%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.05 @ mid -span
0.76
Passed (L/1915)
1.0 D + 0.45 W + 0.75 L + 0.75 S
Bending/Compression
0.79
1
Passed (79%)
1.15
1.0 D + 1.0 S
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• The column stability factor (Kf = 0.6) applied to this design assumes nailed built-up columns per NDS section 15.3.3. For Weyerhaeuser ELP products refer to
the U.S. Wall Guide for multiple -member connection requirements.
Supports
Type
Material
Top
Dbl 2X
Douglas Fir -Larch
Base
2X
Douglas Fir -Larch
Max Unbraced Length Comments
177 1/2"
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type : Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Dead
Snow
Vertical Load
Tributary Width
■
(0.90)
(1.15)
Comments
1 - Point (lb)
N/A
3039
4791
Beam B3
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.5
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33% Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/21/2024 10:15:18 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
aFORTEWEB'
MEMBER REPORT
Unit 3 Roof, Max HDR span
2 piece(s) 1 3/4" x 7 1/4" 2.0E Microllam@ LVL
PASSED
0
I.
1❑
6''
❑2
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1870 @ 0
3806 (1.50")
Passed (49%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1558 @ 8 3/4"
5544
Passed (28%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
4090 @ 4' 4 1/2"
8182
Passed (50%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.167 @ 4' 4 1/2"
0.292
Passed (L/628)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.272 @ 4' 4 1/2"
0.313
Passed (L/386)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (5/16").
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Trimmer - SPF
1.50"
1.50"
1.50"
721
1148
1870
None
2 - Trimmer - SPF
1.50"
1.50"
1.50"
721
1148
1870
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
8' 9" o/c
Bottom Edge (Lu)
8' 9" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location
Tributary
(0.90)
(1.15)
Comments
Width
0 - Self Weight (PLF)
0 to 8' 9"
N/A
7.4
1 - Uniform (PSF)
0 to 8' 9"
10' 6"
15.0
25.0
Roof
0
Member Length : 8' 9"
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/21/2024 10:17:23 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
aFORTEWEB'
MEMBER REPORT
Unit 3 Roof, HDR HI
2 piece(s) 1 3/4" x 9 1/4" 2.0E Microllam@ LVL
PASSED
0
I.
El
9 3
E
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2040 @ 0
3806 (1.50")
Passed (54%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1655 @ 10 3/4"
7074
Passed (23%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
4845 @ 4' 9"
12884
Passed (38%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.115 @ 4' 9"
0.317
Passed (L/994)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.188 @ 4' 9"
0.475
Passed (L/607)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Trimmer - SPF
1.50"
1.50"
1.50"
793
1247
2040
None
2 - Trimmer - SPF
1.50"
1.50"
1.50"
793
1247
2040
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
9' 6" o/c
Bottom Edge (Lu)
9' 6" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location
Tributary
(0.90)
(1.15)
Comments
Width
0 - Self Weight (PLF)
0 to 9' 6"
N/A
9.4
1 - Uniform (PSF)
0 to 9' 6"
10' 6"
15.0
25.0
Roof
0
Member Length : 9' 6"
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/21/2024 11:59:12 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
aFORTEWEB'
MEMBER REPORT
Unit 3 Roof, Corner HDR
1 piece(s) 4 x 10 HF No.2
PASSED
0
1❑
❑2
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
276 @ 0
2126 (1.50")
Passed (13%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
197 @ 10 3/4"
3723
Passed (5%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
431 @ 3' 1 1/2"
4879
Passed (9%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.006 @ 3' 1 1/2"
0.208
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.010 @ 3' 1 1/2"
0.313
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories IF
Total
Available
Required
Dead
Snow
Factored
1 - Trimmer - SPF
1.50"
1.50"
1.50"
119
156
276
None
2 - Trimmer - SPF
1.50"
1.50"
1.50"
119
156
276
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
6' 3" o/c
Bottom Edge (Lu)
6' 3" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location
Tributary
(0.90)
(1.15)
Comments
Width
0 - Self Weight (PLF)
0 to 6' 3"
N/A
8.2
1 - Uniform (PSF)
0 to 6' 3"
2'
15.0
25.0
Roof
0
Member Length : 63"
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
iocument-library.
fhe product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/21/2024 10:20:41 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
.I FORTE W E B MEMBER REPORT
Unit 3 Roof, Corner Post
1 piece(s) 4 x 4 HF No.2
PASSED
Wall Height: 8' Member Height: 7' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
26
50
Passed (52%)
Compression (Ibs)
1062
6372
Passed (17%)
1.15
1.0 D + 1.0 S
Plate Bearing (Ibs)
1062
5206
Passed (20%)
--
1.0 D + 1.0 S
Lateral Reaction (Ibs)
58
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
54
1960
Passed (3%)
1.60
1.0 D + 0.6 W
Lateral Moment (ft-Ibs)
111 @ mid -span
1215
Passed (9%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.07 @ mid -span
0.76
Passed (L/1355)
1.0 D + 0.6 W
Bending/Compression
0.17
1
Passed (17%)
1.60
1.0 D + 0.6 W
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation.
Supports
Type
Material
Top
Dbl 2X
Spruce -Pine -Fir
Base
2X
Spruce -Pine -Fir
Drawing is Conceptual I Max Unbraced Length Comments
177 112"
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type: Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Loads
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
1 - Point (lb)
N/A
787
-
HDR 1
2 - Point (lb)
N/A
119
156
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.5
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/21/2024 10:22:09 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
ESGDESIGN
UPPER FLOOR FRAMING SCHEME
QG HF#2 F
6x6 HF#2 F0
(3)2x6 I
TR MMER 5
MIN. 4x6 HF#:
Eli Grassley, P.E.
F#2
5TUD5
D
HF#2
!ER 5TUD5
ix6 HF#2 P05T
D w/
HANK
J
ENGINEERED STRUCTURES GLOBAL DESIGN Edmonds — Lot 3
a FO RT E W E B MEMBER REPORT PASSED
Unit 3 Upper Floor, Upper Floor Joists
1 piece(s) 11 7/8" TJI@ 360 @ 12" OC
Overall Length. 21' 9"
21' 2"
a
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
592 @ 2 1/2"
1202 (2.25")
Passed (49%)
1.00
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
582 @ 3 1/2"
1705
Passed (34%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
3129 @ 10' 10 1/2"
6180
Passed (51%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.428 @ 10' 10 1/2"
0.711
Passed (L/598)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.588 @ 10' 10 1/2"
1.067
Passed (L/435)
1.0 D + 1.0 L (All Spans)
TJ-Pro"" Rating
37
35
Passed
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser EdgeTM Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-ProT" Rating include: None.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Factored
1 - Stud wall - SPF
3.50"
2.25"
1.75"
163
435
598
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.75"
163
435
598
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
54" o/c
Bottom Edge (Lu)
21' 7" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
-Maximum allowable bracing intervals based on applied load.
Vertical Load
Location
Spacing
Dead
(0.90)
Floor Live
(1.00)
Comments
1 - Uniform (PSF)
0 to 21' 9"
12"
15.0
40.0
Floor
Member Length : 21' 6 1/2"
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 5:44:28 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
ESG Design
www.esg-design.com
BeamChek v2023 licensed to: Markiian Trembach Reg # 5508-68673
Edmonds x4 - Lot 3 Beam B4
Prepared by: MT Date: 6/21/24
Selection W 12x 30 50 ksi Wide Flange Steel Lateral Support: Lc = 5.8 ft max.
Conditions Actual Size is 6-1/2 x 12-3/8 in.
Min Bearing Length R1= 0.9 in. R2= 0.9 in. (1.0) DL Defl= 0.25 in Recom Camber= 0.37 in
Data
Attributes
Critical
Status
Ratio
Values
Adiustments
Beam Span
17.66 ft
Reaction 1 LL
10651 # Reaction 2 LL 12159 #
Beam Wt per ft
30.0 #
Reaction 1 TL
15745 # Reaction 2 TL 18208 #
Bm Wt Included
530 #
Maximum V
18208 #
Max Moment
99964 '#
Max V (Reduced)
N/A
TL Max Defl
L / 240
TL Actual Defl
L / 289
LL Max Defl
L / 360
LL Actual Defl
L / 437
Section (in3)
Shear (in2)
TL Defl (in)
LL Defl
38.60
3.21
0.73
0.48
36.35
0.91
0.88
0.59
OK
OK
OK
OK
94%
28%
83%
82%
Fb (psi)
Fv (psi) E (psi x mil)
Ref. Value Fy 50000
Adjusted Values 33000
50000 29.0
20000 29.0
YP Factor, Lc
At Point Loads:
B = 0.9
0.66 0.40
Provide these minimum bearing lengths in inches or provide web stiffeners.
Loads Uniform LL: 840 Uniform TL: 1155 = A
Point LL Point TL Distance
7976 B = 13026 10.5
Uniform Load A
Pt loads:
0
R1 = 15745 R2 = 18208
SPAN = 17.66 FT
Uniform and partial uniform loads are Ibs per lineal ft.
.I FORTE W E B MEMBER REPORT
Unit 3 Upper Floor, Beam B4 Exterior wall post
1 piece(s) 5 1/4" x 5 1/4" 1.8E Parallam@ PSL
PASSED
Drawing is Conceptual
Wall Height: 9' Member Height: 8' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
18
50
Passed (37%)
Compression (Ibs)
14062
52037
Passed (27%)
1.15
1.0 D + 0.75 L + 0.75 S
Plate Bearing (Ibs)
14062
17227
Passed (82%)
1.0 D + 0.75 L + 0.75 S
Lateral Reaction (Ibs)
65
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
58
6762
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
140 @ mid -span
8812
Passed (2%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.08 @ mid -span
0.86
Passed (L/1244)
1.0 D + 0.45 W + 0.75 L + 0.75 S
Bending/Compression
0.28
1
Passed (28%)
1.15
1.0 D + 0.75 L + 0.75 S
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• Bearing shall be on a metal plate or strap, or on other equivalently durable, rigid, homogeneous material with sufficient stiffness to distribute applied load.
• This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation.
Supports
Type
Material
Top
Dbl 2X
Douglas Fir -Larch
Base
2X
Douglas Fir -Larch
Max Unbraced Length Comments
8'
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type : Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
1 - Point (lb)
N/A
1714
-
2778
Beam B1
2 - Point (lb)
N/A
3940
6160
2272
Beam B4
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.1
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/21/2024 11:49:20 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
aFORTEWEB'
MEMBER REPORT
Unit 3 Upper Floor, Beam B5
2 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam@ LVL
PASSED
0
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3818 @ 2"
5206 (3.50")
Passed (73%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
3098 @ 1' 3 3/8"
7897
Passed (39%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
12336 @ 6' 9 1/2"
17848
Passed (69%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.308 @ 6' 9 1/2"
0.442
Passed (L/516)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.433 @ 6' 9 1/2"
0.663
Passed (L/367)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Factored
1 - Stud wall - SPF
3.50"
3.50"
2.57"
1101
2717
3818
Blocking
2 - Stud wall - SPF
3.50"
3.50"
2.57"
1101
2717
3818
Blocking
• 131001(ing Naneis are assumea to carry no ioaas appnea airecay aoove tnem ana the ruu ioaa is appuea to me memoer Deing aesignea.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
10' 11" o/c
Bottom Edge (Lu)
13' 7" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary
Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
0 to 13' 7"
N/A
12.1
1 - Uniform (PSF)
0 to 13' 7" (Front)
10'
15.0
40.0
Floor
• aiae ioaas are assumea to not inauce cross -grain tension.
0
Member Length : 13' 7"
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/21/2024 11:26:05 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
.I FORTE W E B MEMBER REPORT
Unit 3 Upper Floor, Beams B4-B5 Post
1 piece(s) 5 1/4" x 5 1/4" 1.8E Parallam@ PSL
PASSED
Drawing is Conceptual
Wall Height: 9' Member Height: 8' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
18
50
Passed (37%)
Compression (Ibs)
16091
49437
Passed (33%)
1.00
1.0 D + 1.0 L
Plate Bearing (Ibs)
16091
17227
Passed (93%)
1.0 D + 1.0 L
Lateral Reaction (Ibs)
65
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
58
6762
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
140 @ mid -span
8812
Passed (2%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.09 @ mid -span
0.86
Passed (L/1135)
1.0 D + 0.45 W + 0.75 L + 0.75 S
Bending/Compression
0.39
1
Passed (39%)
1.00
1.0 D + 1.0 L
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• Bearing shall be on a metal plate or strap, or on other equivalently durable, rigid, homogeneous material with sufficient stiffness to distribute applied load.
• This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation.
Supports
Type
Material
Top
Dbl 2X
Douglas Fir -Larch
Base
2X
Douglas Fir -Larch
Max Unbraced Length Comments
8'
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type : Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
1 - Point (lb)
N/A
6112
6161
2272
Beam B4
2 - Point (lb)
N/A
1101
2717
-
Beam 5
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.1
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/21/2024 11:49:32 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
.I FORTE W E B MEMBER REPORT
Unit 3 Upper Floor, B5 Post
3 piece(s) 2 x 6 HF No.2
PASSED
Drawing is Conceptual
Wall Height: 9' Member Height: 8' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
21
50
Passed (43%)
Compression (Ibs)
3818
10533
Passed (36%)
1.00
1.0 D + 1.0 L
Plate Bearing (Ibs)
3818
15469
Passed (25%)
1.0 D + 1.0 L
Lateral Reaction (Ibs)
65
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
58
3960
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
140 @ mid -span
3314
Passed (4%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.04 @ mid -span
0.86
Passed (L/2835)
1.0 D + 0.45 W + 0.75 L + 0.75 S
Bending/Compression
0.30
1
Passed (30%)
1.00
1.0 D + 1.0 L
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• The column stability factor (Kf = 0.6) applied to this design assumes nailed built-up columns per NDS section 15.3.3. For Weyerhaeuser ELP products refer to
the U.S. Wall Guide for multiple -member connection requirements.
Supports
Type
Material
Top
Dbl 2X
Douglas Fir -Larch
Base
2X
Douglas Fir -Larch
Max Unbraced Length Comments
8'
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type : Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Load
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
1 - Point (lb)
N/A
1101
2717
Beam 5
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.1
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33% Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/21/2024 11:50:22 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
aFORTEWEB'
MEMBER REPORT
Unit 3 Upper Floor, HDR H2
2 piece(s) 1 3/4" x 9 1/4" 2.0E Microllam@ LVL
PASSED
0
I.
Fil
9'
9
E
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2657 @ 1 1/2"
7613 (3.00")
Passed (35%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
2086 @ 1' 1/4"
6151
Passed (34%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
5983 @ 4' 9"
11204
Passed (53%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.158 @ 4' 9"
0.308
Passed (L/703)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.221 @ 4' 9"
0.463
Passed (L/503)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Factored
1 - Trimmer - SPF
3.00"
3.00"
1.50"
757
1900
2657
None
2 - Trimmer - SPF
3.00"
3.00"
1.50"
757
1900
2657
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
9' 6" o/c
Bottom Edge (Lu)
9' 6" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location
Tributary
(0.90)
(1.00)
Comments
Width
0 - Self Weight (PLF)
0 to 9' 6"
N/A
9.4
1 - Uniform (PSF)
0 to 9' 6"
10'
15.0
40.0
Floor
0
Member Length : 9' 6"
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/21/2024 11:59:23 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
.I FORTE W E B MEMBER REPORT
Unit 3 Upper Floor, H2 Post
1 piece(s) 4 x 6 HF NO.2
PASSED
Drawing is Conceptual
Wall Height: 9' Member Height: 8' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
27
50
Passed (55%)
Compression (Ibs)
3910
9143
Passed (43%)
1.15
1.0 D + 0.75 L + 0.75 S
Plate Bearing (Ibs)
3910
8181
Passed (48%)
1.0 D + 0.75 L + 0.75 S
Lateral Reaction (Ibs)
65
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
58
3080
Passed (2%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
140 @ mid -span
2558
Passed (5%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.05 @ mid -span
0.86
Passed (L/1894)
1.0 D + 0.45 W + 0.75 L + 0.75 S
Bending/Compression
0.39
1
Passed (39%)
1.15
1.0 D + 0.75 L + 0.75 S
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
Supports
Type
Material
Top
Dbl 2X
Spruce -Pine -Fir
Base
2X
Spruce -Pine -Fir
Max Unbraced Length Comments
8'
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type: Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
1 - Point (lb)
N/A
793
-
1247
HI Post
2 - Point (lb)
N/A
757
1900
-
H2
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.1
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 5:32:18 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
aFORTEWEB'
MEMBER REPORT
Unit 3 Upper Floor, HDR H3
2 piece(s) 1 3/4" x 9 1/4" 2.0E Microllam@ LVL
PASSED
0
I.
0
9
E
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3812 @ 1 1/2"
7613 (3.00")
Passed (50%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
2614 @ 1' 1/4"
6151
Passed (42%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
6887 @ 4' 3"
11204
Passed (61%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.125 @ 4' 3"
0.275
Passed (L/793)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.230 @ 4' 3"
0.412
Passed (L/431)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Factored
1 - Trimmer - SPF
3.00"
3.00"
1.50"
1740
1700
1062
3812
None
2 - Trimmer - SPF
3.00"
3.00"
1.50"
1740
1700
1062
3812
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
8' 6" o/c
Bottom Edge (Lu)
8' 6" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary
Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.1s)
Comments
0 - Self Weight (PLF)
0 to 8' 6"
N/A
9.4
1 - Uniform (PSF)
0 to 8' 6"
10'
15.0
40.0
Floor
2 - Uniform (PLF)
0 to 8' 6"
N/A
100.0
Upper Floor Wall
3 - Uniform (PSF)
0 to 8' 6"
10'
15.0
25.0
Roof
0
Member Length : 8' 6"
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
iocument-library.
fhe product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 12:05:07 AM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
ESG Design
www.esg-design.com
BeamChek v2023 licensed to: Markiian Trembach Reg # 5508-68673
Edmonds x4 - Lot 3 Garage HDR H4
Prepared by: MT Date: 8/05/24
Selection W 14x 30 50 ksi Wide Flange Steel Lateral Support: Lc = 6 ft max.
Conditions Actual Size is 6-3/4 x 13-7/8 in.
Min Bearing Length R1= 0.9 in. R2= 0.9 in. (1.0) DL Defl= 0.13 in Recom Camber= 0.20 in
Data
Attributes
Critical
Status
Ratio
Values
Adiustments
Beam Span
18.0 ft
Reaction 1 LL
6444 # Reaction 2 LL 6444 #
Beam Wt per ft
30.0 #
Reaction 1 TL
10575 # Reaction 2 TL 10575 #
Bm Wt Included
540 #
Maximum V
10575 #
Max Moment
47588 '#
Max V (Reduced)
N/A
TL Max Defl
L / 240
TL Actual Defl
L / 641
LL Max Defl
L / 360
LL Actual Defl
L / >1000
Section (in3)
Shear (in2)
TL Defl (in)
LL Defl
42.00
3.74
0.34
0.20
17.30
0.53
0.90
0.60
OK
OK
OK
OK
41%
14%
37%
34%
Fb (psi)
Fv (psi) E (psi x mil)
Ref. Value Fy
Adjusted Values
50000
33000
50000 29.0
20000 29.0
YP Factor, Lc
0.66
0.40
Loads Uniform LL: 440 Uniform TL: 605 = A
Par Unif LL Par Unif TL Start End
1 H = 100 0 18.0
275 1 = 440 0 18.0
I
H
Uniform Load A
0
R1 = 10575 R2 = 10575
SPAN = 18 FT
Uniform and partial uniform loads are Ibs per lineal ft.
.I FORTE W E B MEMBER REPORT
Unit 3 Upper Floor, H4 Post
1 piece(s) 6 x 6 HF No.2
PASSED
Wall Height: 8' Member Height: 7' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
17
50
Passed (33%)
Compression (Ibs)
8290
15175
Passed (55%)
1.00
1.0 D + 1.0 L
Plate Bearing (Ibs)
9181
12856
Passed (71%)
--
1.0 D + 0.75 L + 0.75 S
Lateral Reaction (Ibs)
58
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
51
4517
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
111 @ mid -span
2126
Passed (5%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.06 @ mid -span
0.76
Passed (L/1496)
1.0 D + 0.45 W + 0.75 L + 0.75 S
Bending/Compression
0.95
1
Passed (95%)
1.00
1.0 D + 1.0 L
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation.
Supports
Type
Material
Top
Dbl 2X
Spruce -Pine -Fir
Base
2X
Spruce -Pine -Fir
Drawing is Conceptual I Max Unbraced Length Comments
177 112"
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type: Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Load
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
1 - Point (lb)
N/A
4220
4070
2544
HDR load
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.5
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 12:15:53 AM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
aFORTEWEB'
MEMBER REPORT
Unit 3 Upper Floor, HDR H5
2 piece(s) 1 3/4" x 7 1/4" 2.0E Microllam@ LVL
PASSED
0
Overall Length. 3' 2"
PM 9
2 S
Fil
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1840 @ 1 1/2"
7613 (3.00")
Passed (24%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
848 @ 10 1/4"
4821
Passed (18%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
1236 @ 1' 7"
7115
Passed (17%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.010 @ 1' 7"
0.097
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.014 @ 1' 7"
0.146
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Factored
1 - Trimmer - SPF
3.00"
3.00"
1.50"
510
1330
1840
None
2 - Trimmer - SPF
3.00"
3.00"
1.50"
510
1330
1840
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
3' 2" o/c
Bottom Edge (Lu)
3' 2" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location
Tributary
(0.90)
(1.00)
Comments
Width
0 - Self Weight (PLF)
0 to 3' 2"
N/A
7.4
1 - Uniform (PSF)
0 to 3' 2"
21'
15.0
40.0
Floor
0
Member Length : 3' 2"
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 5:28:12 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
ESGDESIGN
MAIN FLOOR FRAMING SCHEME
P.T. 11W CDX T&G ATTACHED W/
HDG 16d RING OR SCREW SHANK
NAILS @ 4/12 PATTERN. 4' CONC.
TOPPING SLAB (HOLD TOP OF
JOISTS 434DOWN FROM FLOOR
FRAMING, TYP @ GARAGE)
a-o d
M a J e
24"x24"PAD
MIN. 10"-WIDE THICKENED '
UNDER POST
SIAB AT BEARING WALL
BEAM 87 �
3
z3
DROPPED)
a
O
(3)2xG 705T
N N 11
24g4kkk24'MM PM
,d
EACH END p N
N
Uf�DER.P05T
MIN. 20'-WIDE FOOTING NT
'A/ AT IERIOR BEARING WALL
OF
0
�O
N
\
"'S55
a
42142' PAD
7UNDER
' POST
5-1/4"x5-1/4" 1.8E P5L F45T
UNDER I ABOVE
/MIN. 0" 1DETHICKINED
/ 5B AT BEARING
1A
Tppl
WALL
,
•
-
UNDER POST
.•� _ _ _ _ _ _ _ _ _ _ _ BEARING WALL
" LF+2
6xG HF#2 P05T
,J
`2•
566-@-16'bz
N I I -7/8' TJI360 @ 2'oc
-
DBL 1Y"x11 "20E LVL p.
O
11-7161 TJ13W @12'—
_
p
� V
m N
1.8E P5L P05T
—
'`-
1Da 11W LSL RIM'
11/" TJI-230 @
16"o.c.
�'
'
48"x48" PAD
LL
O�
C3
�Y Oa
Z. N
1 1-7/8" TJ13G0 @ 12'oc a
MIN. 20'-WIDE FOOTING
AT INTERIOR BFEIMNG WALL
s\ 1Yq''X11U" LSL RIM (TYP U.N.O.)
`MIN. 12'-WIDE FOOTING
AT SOUTH EXTERIOR WALL
21'-2' 19'-7
Eli Grassley, P.E.
HDR
DEL. 1Ya'x7%' 2.0E LVL
MIN. 4x611F#2 P05T
r
K
24k24_PAD�--i
24'x24' PAD
UNDER PO5T
24 x24"x12' FTG. 2 6'
#4 BAR EA. WA
HOLD 2" ABOVE BOTT M
FTG (TYP @ DECK) l
OK
J
P/T 4.4 NF#2
KNEE BRACE AT P05T
TOTAL OF (2)
P.T. 2x8 HF#2 LEDGER ATTACH TO
STRUCTURE w/ HDG %'x4'h' SIDS
SCREWS*49 .FS:A6�o�^P AT 5'(3 ER BAY
(3)2x6 NF#2 FOR 16' JOISTS)
TRIMMER STUDS ABU6Z BASE W/ P.T.
6x6 DF#2 POST (TYP
@ DECK)
L T
/ \
MIN. 4x6 H112 105T
DEL. 1N"x7Y." 2.0E LVL CD &G ATTACHED w/
MDR 12d RI OR SCREW SHANK
NAILS 4/12 PATTERN
ENGINEERED STRUCTURES GLOBAL DESIGN Edmonds — Lot 3
a FO RT E W E B MEMBER REPORT PASSED
Unit 3 Main Floor, Main Floor Joists
1 piece(s) 11 7/8" THO 360 @ 12" OC
Overall Length. 21' 9"
21' 2"
a
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
592 @ 2 1/2"
1202 (2.25")
Passed (49%)
1.00
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
582 @ 3 1/2"
1705
Passed (34%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
3129 @ 10' 10 1/2"
6180
Passed (51%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.428 @ 10' 10 1/2"
0.711
Passed (L/598)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.588 @ 10' 10 1/2"
1.067
Passed (L/435)
1.0 D + 1.0 L (All Spans)
TJ-Pro"" Rating
37
35
Passed
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser EdgeTM Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-ProT" Rating include: None.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Factored
1 - Stud wall - SPF
3.50"
2.25"
1.75"
163
435
598
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.75"
163
435
598
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
54" o/c
Bottom Edge (Lu)
21' 7" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
-Maximum allowable bracing intervals based on applied load.
Vertical Load
Location
Spacing
Dead
(0.90)
Floor Live
(1.00)
Comments
1 - Uniform (PSF)
0 to 21' 9"
12"
15.0
40.0
Floor
Member Length : 21' 6 1/2"
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 5:44:28 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
a FO RT E W E B MEMBER REPORT PASSED
Unit 3 Main Floor, Garage Floor Joists
1 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam@ LVL @ 16" OC
I,_1, 3,
C
0
0
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
556 @ 10' 9 1/2"
1969 (1.50")
Passed (28%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
450 @ 9' 9 5/8"
3948
Passed (11%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
1447 @ 5' 7"
9281
Passed (16%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.038 @ 5' 7"
0.347
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.060 @ 5' 7"
0.521
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
TJ-Pro"" Rating
65
35
Passed
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A 4% increase in the moment capacity has been added to account for repetitive member usage.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser EdgeTM Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-ProTM Rating include: None.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Factored
1 - Stud wall - HF
5.50"
4.25"
1.50"
223
372
596
1 1/4" Rim Board
2 - Hanger on 11 7/8" GLB beam
5.50"
Hanger'
1.50"
227
378
604
See note'
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• ' See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
10' 8" o/c
Bottom Edge (Lu)
10' 8" o/c
-Maximum allowable bracing intervals based on applied load.
Member Length : 10' 8 1/4"
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
2 - Face Mount Hanger
IUS1.81/9.5
2.00"
N/A
8-10dx1.5
2-10dx1.5
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Vertical Load
Location (Side)
Spacing
Dead
(0.90)
Floor Live
(1.00)
Comments
1 - Uniform (PSF)
0 to IVY
16"
30.0
50.0
Floor Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/18/2024 9:14:40 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
a FORTE W GB MEMBER REPORT
Unit 3 Main Floor, Beam B6
2 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam@ LVL
PASSED
Overcall Length 13' 9"
r
r
0
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
4198 @ 2"
5206 (3.50")
Passed (81%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
4513 @ 12' 3 5/8"
7897
Passed (57%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
14987 @ 7' 5 5/8"
17848
Passed (84%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.380 @ 6' 11 5/16"
0.442
Passed (L/418)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.532 @ 6' 11 1/4"
0.663
Passed (L/299)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Factored
1 - Stud wall - SPF
3.50"
3.50"
2.82"
1205
2994
4198
Blocking
2 - Stud wall - SPF
5.50"
5.50"
4.07"
1712
4340
6052
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
T 5" o/c
Bottom Edge (Lu)
13' 9" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary
Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
0 to 13' 9"
N/A
12.1
1 - Uniform (PSF)
0 to 13' 9" (Front)
10'
15.0
40.0
Floor
2 - Uniform (PSF)
9' 4" to 13' 6" (Front)
11'
15.0
40.0
Floor
• Side loads are assumed to not induce cross -grain tension.
Member Length : 13' 9"
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 5:54:22 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
.I FORTE W E B MEMBER REPORT
Unit 3 Main Floor, Beam B6 North Post
1 piece(s) 6 x 6 HF No.2
PASSED
Wall Height: 8' Member Height: 7' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
17
50
Passed (33%)
Compression (Ibs)
8017
15175
Passed (53%)
1.00
1.0 D + 1.0 L
Plate Bearing (Ibs)
8017
20268
Passed (40%)
--
1.0 D + 1.0 L
Lateral Reaction (Ibs)
58
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
51
4517
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
111 @ mid -span
2126
Passed (5%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.05 @ mid -span
0.76
Passed (L/1945)
1.0 D + 1.0 L
Bending/Compression
0.90
1
Passed (90%)
1.00
1.0 D + 1.0 L
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation.
Supports
Type
Material
Top
Dbl 2X
TimberStrand@ LSL
Base
2X
TimberStrand@ LSL
Drawing is Conceptual I Max Unbraced Length Comments
177 112"
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type: Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
1 - Point (lb)
N/A
1101
2717
Beam 5
2 - Point (lb)
N/A
1205
2994
Beam B6
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.5
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 7:26:21 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
.I FORTE W E B MEMBER REPORT
Unit 3 Main Floor, Beam B6 South Post
1 piece(s) 5 1/4" x 7" 1.8E Parallam@ PSL
PASSED
Wall Height: 8' Member Height: 7' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
17
50
Passed (35%)
Compression (Ibs)
20290
69460
Passed (29%)
1.00
1.0 D + 1.0 L
Plate Bearing (Ibs)
20290
22969
Passed (88%)
1.0 D + 1.0 L
Lateral Reaction (Ibs)
58
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
49
9016
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
111 @ mid -span
15024
Passed (1%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.05 @ mid -span
0.76
Passed (L/1944)
1.0 D + 1.0 L
Bending/Compression
0.32
1
Passed (32%)
1.00
1.0 D + 1.0 L
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• Bearing shall be on a metal plate or strap, or on other equivalently durable, rigid, homogeneous material with sufficient stiffness to distribute applied load.
Supports
Type
Material
Top
Dbl 2X
Douglas Fir -Larch
Base
2X
Douglas Fir -Larch
Drawing is Conceptual I Max Unbraced Length Comments
177 112"
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type: Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
1 - Point (lb)
N/A
6112
6161
2272
Beam B4
2 - Point (lb)
N/A
1101
2717
-
Beam 5
3 - Point (lb)
N/A
1205
2994
-
Beam B6
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.5
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 7:24:43 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
aFORTEWEB'
MEMBER REPORT
Unit 3 Main Floor, Beam B7
2 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam@ LVL
PASSED
0
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
4721 @ 2"
5206 (3.50")
Passed (91%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
3578 @ 1' 3 3/8"
7897
Passed (45%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
11716 @ 5' 3 1/2"
17848
Passed (66%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.160 @ 5' 3 1/2"
0.342
Passed (L/769)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.259 @ 5' 3 1/2"
0.512
Passed (L/474)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Factored
1 - Stud wall - SPF
3.50"
3.50"
3.17"
1810
2910
4721
Blocking
2 - Stud wall - SPF
3.50"
3.50"
3.17"
1810
2910
4721
Blocking
• 131001(ing Naneis are assumea to carry no ioaas appnea airecay aoove tnem ana the ruu ioaa is appuea to me memoer Deing aesignea.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
10' 7" o/c
Bottom Edge (Lu)
10' 7" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary
Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
0 to 10' 7"
N/A
12.1
1 - Uniform (PSF)
0 to 10' 7" (Front)
11'
30.0
50.0
Garage floor
• aiae ioaas are assumea to not inauce cross -grain tension.
0
Member Length : 10' 7"
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 6:15:11 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds 0 Units
Page 1 / 1
.I FORTE W E B MEMBER REPORT
Unit 3 Main Floor, Beam B7 Post
3 piece(s) 2 x 6 HF No.2
PASSED
Drawing is Conceptual
Wall Height: 8' Member Height: 7' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
20
50
Passed (41%)
Compression (Ibs)
4720
11304
Passed (42%)
1.00
1.0 D + 1.0 L
Plate Bearing (Ibs)
4720
10519
Passed (45%)
--
1.0 D + 1.0 L
Lateral Reaction (Ibs)
58
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
51
3960
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
111 @ mid -span
3315
Passed (3%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.03 @ mid -span
0.76
Passed (L/2881)
1.0 D + 0.45 W + 0.75 L + 0.75 S
Bending/Compression
0.38
1
Passed (38%)
1.00
1.0 D + 1.0 L
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• The column stability factor (Kf = 0.6) applied to this design assumes nailed built-up columns per NDS section 15.3.3. For Weyerhaeuser ELP products refer to
the U.S. Wall Guide for multiple -member connection requirements.
Supports
Type
Material
Top
Dbl 2X
Spruce -Pine -Fir
Base
2X
Spruce -Pine -Fir
Max Unbraced Length Comments
177 1/2"
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type : Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Load
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
1 - Point (lb)
N/A
1810
2910
Beam
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.5
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33% Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 6:20:19 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
aFORTEWEB'
MEMBER REPORT
Unit 3 Main Floor, Deck Beam B8
1 piece(s) 6 x 10 HF No.2
PASSED
2"
0
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1624 @ 2"
7796 (3.50")
Passed (21%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
1103 @ 1' 1"
4877
Passed (23%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
2477 @ 3' 4 1/2"
4654
Passed (53%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.034 @ 3' 4 1/2"
0.214
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.042 @ T 4 1/2"
0.321
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Lumber grading provisions must be extended over the length of the member per NDS 4.2.5.5.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Factored
1 - Stud wall - SPF
3.50"
3.50"
1.50"
308
1316
1624
Blocking
2 - Stud wall - SPF
3.50"
3.50"
1.50"
308
1316
1624
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the Lull load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
6' 9" o/c
Bottom Edge (Lu)
6' 9" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary
(0.90)
(1.00)
Comments
Width
0 - Self Weight (PLF)
0 to 6' 9"
N/A
13.2
1 - Uniform (PSF)
0 to 6' 9" (Front)
6' 6"
12.0
60.0
Deck
• side loads are assumed to not induce cross -grain tension.
0
Member Length : 6' 9"
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeusercom/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 6:46:00 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
a FO RT E W E B MEMBER REPORT PASSED
Unit 3 Main Floor, Deck Joists
1 piece(s) 2 x 8 HF No.2 @ 16" OC
2'
0
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
606 @ 7' 11 1/4"
2126 (3.50")
Passed (28%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
328 @ 7' 2 1/4"
1088
Passed (30%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
699 @ 4' 1/4"
1284
Passed (54%)
1.00
1.0 D + 1.0 L (Alt Spans)
Live Load Defl. (in)
0.104 @ 4' 7/8"
0.193
Passed (L/894)
1.0 D + 1.0 L (Alt Spans)
Total Load Defl. (in)
0.121 @ 4' 11/16"
0.386
Passed (L/769)
1.0 D + 1.0 L (Alt Spans)
TJ-Pro"" Rating
N/A
N/A
N/A
N/A
• Deflection criteria: LL (L/480) and TL (L/240).
• Overhang deflection criteria: LL (2L/480) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A 15% increase in the moment capacity has been added to account for repetitive member usage.
• Applicable calculations are based on NDS.
• No composite action between deck and joist was considered in analysis.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Factored
1 - Stud wall - SPF
3.50"
2.25"
1.50"
60
326/-15
386
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
3.50"
1.50"
101
505
606
Blocking
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing Bracing Intervals
Comments
Top Edge (Lu) 10' o/c
Bottom Edge (Lu) 10' o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Load
Location (Side)
Spacing
Dead
(0.90)
Floor Live
(1.00)
Comments
1 - Uniform (PSF)
0 to 10' 1"
16"
12.0
60.0
Deck
Notes
Member Length : 9' 11 3/4"
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 6:43:51 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
aFORTEWEB'
MEMBER REPORT
Unit 3 Main Floor, Header H6
2 piece(s) 1 3/4" x 7 1/4" 2.0E Microllam@ LVL
PASSED
0
I.
El
2
E
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2993 @ 0
3806 (1.50")
Passed (79%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
1304 @ 8 3/4"
4821
Passed (27%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
1933 @ 1' 3 1/2"
7115
Passed (27%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.014 @ 1' 3 1/2"
0.086
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.019 @ 1' 3 1/2"
0.129
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Factored
1 - Trimmer - SPF
1.50"
1.50"
1.50"
823
2170
2993
None
2 - Trimmer - SPF
1.50"
1.50"
1.50"
823
2170
2993
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
2' 7" o/c
Bottom Edge (Lu)
2' 7" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location
Tributary
(0.90)
(1.00)
Comments
Width
0 - Self Weight (PLF)
0 to 2' 7"
N/A
7.4
1 - Uniform (PSF)
0 to 2' 7"
21'
15.0
40.0
Upper Floor
2 - Uniform (PSF)
0 to 2' 7"
21'
15.0
40.0
Main Floor
0
Member Length : 2' 7"
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
iocument-library.
fhe product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 6:50:39 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
.I FORTE W E B MEMBER REPORT
Unit 3 Main Floor, H7 Post
1 piece(s) 4 x 6 HF No.2
PASSED
Drawing is Conceptual
Wall Height: 8' Member Height: 7' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
26
50
Passed (52%)
Compression (Ibs)
6107
9799
Passed (62%)
1.00
1.0 D + 1.0 L
Plate Bearing (Ibs)
6107
8181
Passed (75%)
1.0 D + 1.0 L
Lateral Reaction (Ibs)
58
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
51
3080
Passed (2%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
111 @ mid -span
2561
Passed (4%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.06 @ mid -span
0.76
Passed (L/1599)
1.0 D + 0.45 W + 0.75 L + 0.75 S
Bending/Compression
0.78
1
Passed (78%)
1.00
1.0 D + 1.0 L
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
Supports
Type
Material
Top
Dbl 2X
Spruce -Pine -Fir
Base
2X
Spruce -Pine -Fir
Max Unbraced Length Comments
177 1/2"
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type: Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
1 - Point (lb)
N/A
793
-
1247
HI Post
2 - Point (lb)
N/A
757
1900
-
H2
3 - Point (lb)
N/A
757
1900
-
H7
Lateral Load
Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF)
Full Length
1'
25.5
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 6:54:57 PM UTC
AForteWEB 0.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
aFORTEWEB'
MEMBER REPORT
Unit 3 Main Floor, HDR H8
2 piece(s) 1 3/4" x 9 1/4" 2.0E Microllam@ LVL
PASSED
0
I.
0
9
E
Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.).
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3602 @ 1 1/2"
7613 (3.00")
Passed (47%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
2737 @ 1' 1/4"
6151
Passed (44%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
7210 @ 4' 3"
11204
Passed (64%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.164 @ 4' 3"
0.275
Passed (L/604)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.217 @ 4' 3"
0.412
Passed (L/456)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Factored
1 - Trimmer - SPF
3.00"
3.00"
1.50"
882
2720
3602
None
2 - Trimmer - SPF
3.00"
3.00"
1.50"
882
2720
3602
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
8' 6" o/c
Bottom Edge (Lu)
8' 6" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location
Tributary
(0.90)
(1.00)
Comments
Width
0 - Self Weight (PLF)
0 to 8' 6"
N/A
9.4
--
1 - Uniform (PSF)
0 to 8' 6"
10'
15.0
40.0
Floor
2 - Uniform (PSF)
0 to 8' 6"
4'
12.0
60.0
Deck
0
Member Length : 8' 6"
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2021
Design Methodology : ASD
Weyerhaeuser Notes
Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
iocument-library.
fhe product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 6:58:53 PM UTC
ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units
Page 1 / 1
.I FORTE W E B MEMBER REPORT
Unit 3 Main Floor, H8 Post
3 piece(s) 2 x 6 HF No.2
PASSED
Drawing is Conceptual
Wall Height: 8' Member Height: 7' 7 1/2"
Tributary Width: 1'
Design Results
Actual
Allowed
Result
LDF
Load: Combination
Slenderness
20
50
Passed (41%)
Compression (Ibs)
7042
11304
Passed (62%)
1.00
1.0 D + 1.0 L
Plate Bearing (Ibs)
7042
10519
Passed (67%)
1.0 D + 1.0 L
Lateral Reaction (Ibs)
58
1.60
1.0 D + 0.6 W
Lateral Shear (Ibs)
51
3960
Passed (1%)
1.60
1.0 D + 0.6 W
Lateral Moment(ft-Ibs)
111 @ mid -span
3315
Passed (3%)
1.60
1.0 D + 0.6 W
Total Deflection (in)
0.05 @ mid -span
0.76
Passed (L/1891)
1.0 D + 0.45 W + 0.75 L + 0.75 S
Bending/Compression
0.73
1
Passed (73%)
1.00
1.0 D + 1.0 L
• Lateral deflection criteria: Wind (L/120)
• Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
• Applicable calculations are based on NDS.
• The column stability factor (Kf = 0.6) applied to this design assumes nailed built-up columns per NDS section 15.3.3. For Weyerhaeuser ELP products refer to
the U.S. Wall Guide for multiple -member connection requirements.
Supports
Type
Material
Top
Dbl 2X
Spruce -Pine -Fir
Base
2X
Spruce -Pine -Fir
Max Unbraced Length Comments
177 1/2"
Lateral Connections
Supports
Connector
Type/Model
Quantity
Connector Nailing
Top
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
Base
Nails
8d (0.113" x 2 1/2") (Toe)
2
N/A
System : Wall
Member Type : Column
Building Code : IBC 2021
Design Methodology : ASD
• Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Livell� Snow
(1.00) (1.15)
Comments
1 - Point (lb)
N/A
1740
1700 1062
H3 Load
2 - Point (lb)
N/A
882
2720
H8 Load
Lateral Load= Location
Tributary Width
Wind
(1.60)
Comments
1 - Uniform (PSF) Full Length
1'
25.5
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33% Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Wind Zone (4), GCpi
(+/- 0.18), Effective Wind Area determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/
document -library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mark Trembach
ESGD
(701) 660-9422
mark.esgd@outlook.com
6/22/2024 7:09:37 PM UTC
AForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2
Weyerhaeuser File Name: Edmonds x4 Units