REVIEWED BLD2021-0811+Energy_Calculations+6.14.2021_1.34.37_AM+2246972simple cleating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information Quantum Homes, Lot 3 Dante Palmaffy 7901 24oth St SW 12925 47th Dr SE, Everett, WA 98208 Edmonds, WA 425-345-2530 Heating systeln I Vve, _*' All other Systems 0 Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperaturs Instructions - Design Temperature Difference (AT) Edmonds aT = Indoor (70 degrees) - Outdoor Design Temp Area of Iiu001mg Conditioned Floor Area Conditioned Floor Area (sq ft) 5.359 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.8 47,159 Glazing and Doors U-Factor X Area = UA inshrtrrtiorrs ;.. _..... __.. = u-o.zs ' 0.280 1.084 303.52 ISVYUIVN !W Skylights Y` U-Factor X Area = UA Instructions 0.50 © --- Insulation Attic U-Factor X Area = UA instrurticsw� 0.026 0 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA No selection F 2.000 Above Grade Walls (see Ffpure 1) U-Factor X Area UA o No selection F 27900 Floors U-Factor X Area UA Instructions ,r; 0.025 408 10.15 Below Grade Walls (see Figure t) U-Factor X Area UA t R-value �- In'Strvrrtians Select w No selection Slab Below Grade (see Figure 1) 13sttuc;t:orls F-Factor X Length 1,954 UA 592.06 R-10 Fully insulated A-0.303 Slab on Grade (see Figure t) F-Factor X Length UA u� Select R-value - � -c-- NO S210C110n Location of Ducts Instructions -. -- _. - " Duct Leakage Coefficient Conditioned Space Re 1.00 Sum of UA 905.73 Figure 1. Above G d I 46 Envelope Heat Load 41.664 Btu / Hour Sum of UA x \T Air Leakage Heat Load 23,429 Btu / Hour Volume x 0.6 x 1T x 0.018 Building Design Heat Load 65,092 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 65.092 Btu / Hour Ducts in unconditioned space. sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 91,129 Btu / Hour Buildino and duct heat loss x 1.40 for forced air furnace Buildino and duct heat loss x 1.25 for heat pump (07101113)