APPROVED ENG PLN_RESUB 2-Civil_Plan+7.29.2022_2.52.19_PM+3021928PROJECT STATISTICS 2" x 2" WOOD/STEEL FILTER FABRIC SECURED TO 2" x 2" 14 GA WIRE FABRIC EQUAL NATIVE BACKFILL MATERIAL FILTER FABRIC MATERIAL IN CONTINOUS ROLLS USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO WIRE NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER EROSION CONTROL THROUGHOUT PROJECT. CITY INSPECTION REQUIRED ON 2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION ALL EROSION CONTROL METHODS ACTIVITY. OTHER WORK CAN BEGIN REVISION DATE CITY OF EDMONDS FILTER FABRIC FENCE JANUARY 2018 FILTRATION SYSTEMS PUBLIC WORKS STANDARD DEPARTMENT DETAIL `Sf. 189�j APPROVED BY: R. ENGLISH ER-900 _LS A TH IN DE FULL WIDTH GRESS/EGRESS DETAIL NOTES: 10 THE MINIMUM LENGTH SHALL BE EXTENDED AS NECESSARY TO ENSURE MATERIAL IS NOT TRACKED OFF SITE AND/OR INTO THE PUBLIC RIGHT-OF-WAY. O2 ATB DRIVEWAY RAMP AND/OR SITE ACCESS ROAD 15' WIDE MIN. SEE TABLE BELOW FOR REQUIRED LENGTH. NOTES: 1. SURFACE WATER - ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCES SHALL BE PIPED ACROSS THE ENTRANCE. IF PIPING IS IMPRACTICAL, A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMITTED. 2. MAINTENANCE - THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL QUARRY SPALLS AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY MUST BE REMOVED IMMEDIATELY. 3. WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO LEAVING THE SITE. WHEN WASHING IS USED, IT SHALL BE DONE ON AN AREA STABILIZED WITH QUARRY SPALLS AND WHICH DRAINS INTO AN APPROVED SEDIMENT TRAPPING DEVICE. 4. INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN. PROJECT SIZE MIN LENGTH OF (FEET) QUARRY SPALLS* < 1/4 ACRE 30 < 1 ACRE 50 < 3 ACRE 100 > 3 ACRE 100 ■ PROVIDE ATB OR ASPHALT TRANSITION WHERE FRONTAGE ROAD IS AN ARTERIAL. LENGTH TO BE DETERMINED BY CITY INSPECTOR. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN _ REVISION DATE CITY OF EDMONDS STABILIZED CONSTRUCTION JANUARY 2018 ENTRANCE 7c PUBLIC WORKS STANDARD DEPARTMENT DETAIL 189� APPROVED BY: R. ENGLISH E R — 9 01 FILTER SOCK WITH OVER FLOW HOLES (TYP) .SIN NOTES: CATCH BASIN 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN THIS APPLICATION AT ALL TIMES DURING CONSTRUCTION PERIOD. 2. ANY SEDIMENT IN CATCH BASIN INSERT SHALL BE REMOVED WHEN INSERT IS ONE-THIRD FULL. 3. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN. REVISION DATE TEMPORARY JANUARY 2018 CITY OF EDMONDS SEDIMENT TRAP STANDARD 7 PUBLIC WORKS FOR CATCH BASINS DEPARTMENT DETAIL FS t . 18g�3 E R - 9 02 APPROVED BY: R. ENGLISH 6" CLEA 1221 C S LAMPH WITH 1 / GRIPP R A N D 2' COLLA NEW 1" WATER ................ ......... ..... ................ .......... ..... ................ .......... ..... ................ ................ ................ ................ ................ ................ ......... ...... ................ .......... ...... METER WITH �1,.5" HYDROM AXX SERVICE LINE LIMITS 0AREA OF DISTU BANC EROSION C NTR L�oo FENCE LINE O I 0-) TEMPORARY STOCKPILE LOCATION NOUT WITH w... ....... T IRON ....... .......... _E COVER � 2"HEX BOLTS TWIST PLUG � CONCRET� I O � z I.. CB RIM 385.9\7 I E 382.40 R I E 382.70 V IE 383.10 E FILTER SOCKS ER-902 STORM STUB E 383.70 N 9 ? 0 I TE 397.50 GARDEN WALL pp- -�Q�. nn ICLEANI TREE PROTECTI N I IFENCE �R12') DAT M PO NT NAD 8391 � ESSM RIM 387.08 CONCRETE BLOCK WALL (MAX.30"H) I— �IIII III — COMPACTED GRAVEL II' 4"0 PERFORATED FOOTING DRAIN 8" FOOTING PAD SURROUNDED BY WASHED ROCK LOCATED AT THE TOE OF THE (5/8" MINUS) TYP. WALL BELOW 2-4" QUARRY ROCK BACKFILL. PIPES SHALL DAYLIGHT @ EACH END OF THE WALL WITH III ;III ;III A ROCK PAD BELOW OUTFALLS SITE PLAN K'N 4 NORTH TE 400.00 TE 402.50 /j BE 400.00 I LIMITS OF AREA OF DISTURBANCE EROSION CONTROL �ENGE LINE E i 9T/��SETBACKS � I n R a N to � I L/ I \ 1-r\ I I— IJ 2 0�1 I N-�--►—J \7--/ 1 I IS R I R IN to 4" VC LI I S OF RE� \ OF IS URB NC I I ER SION CO TR�L 7 -- - \ E E o-� �1 � g' \ TR E PR TECION \ SS 4" Dion zoo I* \ RA �ED ) I SIDE \StWtK rcb2� MIN. CLEAf\OUT \ \` SIN TSI�DE EWER °, I �R35 I I I LEGEND PROPOSED HOUSE (S.F.R.) [:E22= COVERED/OPEN DECKS DRIVEWAY, SIDEWALK (CONCRETE) W W W W W GRASS LAWN (HYDROSEEDS) DECORATIVE BUSHES/FLOWERS SIGNIFICANT AT MATURITY TREES EROSION CONTROL FENCE 2 0' 0 2 0' STRUCTURAL FILL SHALL BE PLACED IN MAX. 12" THICK LIFTS WHICH SHALL BE COMPACTED TO @ LIST 95% PERCENT OF THE MODIFIED PROCTOR MAX. DRY DENCITY SITE AREA: 12,076.00 SQ.FT. STRUCTURE: 2,852.00 SQ.FT. (COVERED DECK INCLUDED) MAX. LOT COVERAGE: ALLOWED PROPOSED DRIVEWAY: IMPERVIOUS AREA: 4,226.60 SQ.FT.(35%) 2,852.00 SQ. FT. (24%) 1,311.00 SQ.FT. 3,988.00 SQ.FT. GREENSCAPE: 1,652.00 SQ.FT. MAX. BUILDING HEIGHT: ALLOWED 25'-0" PROPOSED 23'-9" AVERAGE HEIGHT CALCULATION A B D C A 1 396.00' B 423.00' C 416.00' 1 D 395.00' TOTAL A — D DIVIDED BY 4: AVERAGE HEIGHT - 407.5' 1,630.00' 407.5' GARAGE FL. ELV. - 395.0' RIDGE ELEVATION - 432.5' NOTES — CONNECT WATER LINE TO A NEW WATER METER (1 ") — CONNECT SANITARY SEWER TO EXISTING SEWER STUB — CONNECT STORM DRAIN TO EXISTING STUB (VIA CATCH BASIN) — COVER ALL OPEN GROUND AREA WITH BARK/MULCH MIX — SEDIMENT SOCKS SHALL BE INSTALLED IN THE CB NEAR AND ACROSS THE STREET — THERE IS NO SIGNIFICANT TREES ON THE PROJECT SITE — (5) SIGNIFICANT AT MATURITY TREES SHALL BE PLANTED — STOCK PILE SHALL BE COVERED WITHIN 24 HOURS — ALL DISTURBED AREAS TO BE COMPOST AMENDED PER 2014 SWMMWW BMP T.5.13 — INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING APPROVED PLANS, CITY OF EDMONDS STANDARD DETAILS, AND ALL OTHER MEASURES REQUIRED DURING CONSTRUCTION — TRACER WIRE SHALL BE INSTALLED ON THE WATER SERVICE LINE — FINAL RESTORATION SHALL BE COMPLETED BY THE CONTRACTOR NOT THE CITY OF EDMONDS — MINIMUM OF 3' HORIZONTAL SEPARATION AND 1' VERTICAL SEPARATION IS REQUIRED BETWEEN DRY UTILITIES SUCH AS POWER, GAS, PHONE, CABLE, ETC. AND SEWER AND STORM 5' FROM ANY CITY MAIN LINE — IF THE RIM INVERT ELEVATION EXCEEDS 5' THEN A TYPE II MANHOLE WILL BE REQUIRED — MINIMUM2' OF COVER IS REQUIRED FOR ALL PIPES LOCATED UNDER DRIVABLE SURFACES AND 1' UNDER LANDSCAPE AREAS — EXISTING FAILING, DAMAGED OR NON—ADA COMPLIANT FRONTAGE IMPROVEMENTS (SIDEWALK AND CURB RAMP) SHALL BE REMOVED AND REPLACED AS DETERMINED BY THE CITY INSPECTOR DRIVEWAY SLOPE SHALL NOT EXCEED 14% SLOPE — SIDE SEWER WILL BE ANCHORED IF SLOPE IS GREATER THAN 20% SEE LETTER FROM GEOTECH ENGINEER FOR RECOMMENDATION — IF THE EXISTING SEWER LATERAL IS PROPOSED TO BE REUSED THE CITY's PUBLIC WORKS DEPARTMENT WILL NEED TV THE LATERAL TO DETERMINE IF IT IS ACCEPTABLE TO RE —USE. CONTACT CITY OF EDMONDS PUBLIC WORK SEWER DIVISION AT (425) 771-0235 TO SCHEDULE INSPECTION. — STORM DRAIN OVERFLOW SHALL CONNECT TO THE STUB ON THE PRIVATE PROPERTY — TREE PROTECTION FENCE SHALL BE PLACED MINIMUM OF 12 FEET FROM THE FACE OF THE TREE TRUNK THE ASSIGNED CERTIFIED ARBORIST SHALL BE PRESENTED ON SITE DURING THE TREE PROTECTION FENCE INSTALLATION — FOR EXISTING SHARED DRIVEWAY EASEMENT CONDITIONS, REFER TO REC.# AFN 200410085349 — RESTORATION OF UTILITY PATCHES WITH LESS THAN 20' OF SEPARATION SHALL BE COMBINED IN FULL OR HALF WIDTH OVERLAY DEPENDING OF THE EXTENT OF DISTURBANCE. IF UTILITY PATCHES FALL ENTIRELY WITHIN ONE TRAVEL LINE, THE OVERLAY SHALL EXTEND TO THE CENTERLINE OF ROADWAY. IF THE UTILITY PATCHES EXTEND INTO BOTH TRAVEL LINES, THEN THE FULL WIDTH OVERLAY SHALL BE REQUIRED — TREE PROTECTION FENCE SHALL BE PLACED AT 12'-0" MIN FROM THE FACE OF TREE TRUNK 0 CV O CV Lf ) CV E U � I cB O �; oz WN 0 U00 z � Lu ul; � o z u) 0 LJJ � � W Qul W J � J a Q � iLr) N A 1021 GENERAL NOTES 1. ALL MATERIALS AND WORK SHOWN ON THESE PLANS SHALL CONFORM TO THE CITY OF EDMONDS STANDARD PLANS AND DETAILS, THE FOLLOWING SPECIFICATIONS AND CODES, AND ALL OTHER APPLICABLE LOCAL MUNICIPAL, STATE, AND FEDERAL CODES, RULES AND REGULATIONS: - CURRENT INTERNATIONAL BUILDING CODE (IBC) - 2016 WSDOT/APWA STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION - WASHINGTON STATE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN (CURRENT EDITION) 2. STANDARD PLAN AND TYPE NUMBERS INDICATED ON THESE DRAWINGS REFER TO CITY OF EDMONDS STANDARD DETAILS, UNLESS NOTED OTHERWISE 3. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOBSITE WHENEVER CONSTRUCTION IS IN PROGRESS. 4. DEVIATIONS FROM THESE PLANS MUST BE APPROVED BY THE ENGINEER OF RECORD AND THE LOCAL GOVERNING AUTHORITY. 5. CONTRACTOR SHALL RECORD ALL APPROVED DEVIATIONS FROM THESE PLANS ON A SET OF "AS -BUILT" DRAWINGS AND SHALL SUMMARIZE ALL AS - BUILT CONDITIONS ON ONE SET OF REPRODUCIBLE DRAWINGS FOR SUBMITTAL TO THE OWNER PRIOR PROJECT COMPLETION AND ACCEPTANCE. A SET OF AS -BUILT DRAWINGS SHALL BE SUBMITTED TO THE CITY OF EDMONDS PRIOR TO FINAL APPROVAL OF THE BUILDING OCCUPANCY/FINAL PROJECT APPROVAL. 6. ELEVATIONS SHOWN ARE IN FEET. SEE SURVEY FOR BENCHMARK INFORMATION. 7. THE LOCATIONS OF EXISTING UTILITIES AND SITE FEATURES SHOWN HEREON HAVE BEEN FURNISHED BY OTHERS BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND PROTECT ANY OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. CONTRACTOR SHALL VERIFY LOCATION, DEPTH, SIZE, TYPE AND CONDITION OF EXISTING UTILITY LINES AT CONNECTION OR CROSSING POINTS BEFORE TRENCHING FOR NEW UTILITIES. ENGINEER ASSUMES NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF THE EXISTING UTILITIES AND SITE FEATURES PRESENTED ON THESE DRAWINGS. ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF CONFLICTS THAT ARISE. 8. CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING CONSTRUCTION AND SHALL CONTACT THE UNDERGROUND UTILITIES GENERAL NOTES / CONSTRUCTION SEQUENCE M:\ LOCATION SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. 9. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE PROJECT SITE BEFORE STARTING WORK AND SHALL NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES. 10. PIPE LENGTHS WHERE SHOWN ARE APPROXIMATE AND MAY CHANGE DUE TO FIELD CONDITIONS. 11. CONTRACTOR SHALL OBTAIN A COPY OF THE GEOTECHNICAL REPORT (WHERE APPLICABLE) AND SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE CONTENTS THEREOF. ALL SITE WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH THE RECOMMENDATIONS OF THIS REPORT. 12. STRUCTURAL FILL MATERIAL AND PLACEMENT SHALL CONFORM TO THE RECOMMENDATIONS OF THE PROJECT GEOTECHNICAL REPORT. 13. SUBGRADE SOILS IN ALL AREAS WHERE RAIN GARDENS, INFILTRATION OR PERVIOUS PAVEMENT IS TO BE PLACED SHALL BE DELINEATED AND PROTECTED AT ALL TIMES FROM COMPACTIVE ACTIVITIES (i.e. HEAVY EQUIPMENT, STOCKPILING). 14. MANHOLES, CATCH BASINS, UTILITIES AND PAVEMENT SHALL BEAR ON MEDIUM DENSE TO VERY DENSE NATIVE SOIL OR COMPACTED STRUCTURAL FILL. IF SOIL IS DISTURBED, SOFT, LOOSE, WET OR IF ORGANIC MATERIAL IS PRESENT AT SUBGRADE ELEVATION, REMOVE AND REPLACE WITH COMPACTED STRUCTURAL FILL PER GEOTECHNICAL REPORT. 15. SEE SURVEY AND ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND LOCATIONS OF BUILDINGS, LANDSCAPED AREAS AND OTHER PROPOSED OR EXISTING SITE FEATURES. 16. SEE ARCHITECTURAL DRAWINGS FOR PERIMETER FOUNDATION DRAINS. FOUNDATION DRAINS SHALL BE INDEPENDENT OF OTHER SITE DRAIN LINES AND SHALL BE TIGHTLINED TO THE STORM DRAIN SYSTEM WHERE INDICATED ON THE PLANS. 17. ALL REQUIRED STORMWATER FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO INSTALLATION OF ANY PAVEMENT UNLESS OTHERWISE APPROVED BY THE ENGINEER. 18. ALL ROOF DRAINS, PERIMETER FOUNDATION DRAINS, CATCH BASINS AND OTHER EXTERNAL DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS NOTED OTHERWISE. 19. ALL FOOTING DRAINS SERVING BUILDINGS, WALLS, ROCKERIES, ETC. SHALL CONNECT TO THE DRAINAGE SYSTEM DOWNSTREAM OF THE SITE STORMWATER DETENTION SYSTEM. EXISTING UTILITIES SHALL BE MADE ONLY WITH ADVANCE WRITTEN APPROVAL OF THE AUTHORITIES GOVERNING SAID UTILITIES. 31. ALL UTILITIES SHALL BE PLACED UNDERGROUND. 32. EXISTING UTILITY LINES IN SERVICE WHICH ARE DAMAGED DUE TO CONSTRUCTION WORK SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE AND INSPECTED AND ACCEPTED BY CITY OF EDMONDS AND OWNER'S REPRESENTATIVE PRIOR TO BACKFILLING. 33. NEW UTILITY LOCATIONS ARE GENERALLY SHOWN BY DIMENSION, WHERE NO DIMENSIONS ARE INDICATED, LOCATIONS MAY BE SCALED FROM DRAWINGS. FIELD ADJUSTMENTS SHALL BE APPROVED BY OWNER'S REPRESENTATIVE AND CITY. 34. FIELD STAKE ALL UTILITY STUBS AT THE PROPERTY LINE. 35. TRENCH BACKFILL OF UTILITIES LOCATED WITHIN THE CITY RIGHT-OF-WAY SHALL BE COMPACTED TO 95%. COMPACTION TEST REPORTS SHALL BE PROVIDED TO THE CITY PRIOR TO PAVING. 36. WHERE NEW PIPE CLEARS AN EXISTING OR NEW UTILITY BY 6" OR LESS, PLACE POLYETHYLENE PLASTIC FOAM AS A CUSHION BETWEEN THE UTILITIES. 37. SEE MECHANICAL DRAWINGS (WHERE APPLICABLE) FOR CONTINUATION OF SITE UTILITIES WITHIN THE BUILDING. 38. SEE ELECTRICAL DRAWINGS (WHERE APPLICABLE) FOR EXTERIOR ELECTRICAL WORK. 39. SEE LANDSCAPE DRAWINGS (WHERE APPLICABLE) FOR SITE IRRIGATION SYSTEM. 40. PIPE MATERIAL AND SIGNAGE SUBMITTALS SHALL BE PROVIDED TO CITY ENGINEERING DIVISION FOR APPROVAL PRIOR TO INSTALLATION. M__m 20. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR INSTALLATION OF ALL SITE IMPROVEMENTS INDICATED ON THESE DRAWINGS. 21. A SEPARATE IRRIGATION PERMIT MUST BE OBTAINED FROM THE CITY PUBLIC WORKS DEPARTMENT. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, PROVIDE TO THE CITY WATER QUALITY TECHNICIAN, A COPY OF THE BACKFLOW TEST REPORT. TEST REPORTS CAN BE FAXED TO 425-744-6057 OR EMAILED TO JEFF.KOBLYK@EDMONDSWA.GOV. BACKFLOW TESTING SHALL BE COMPLETED BY THE OWNER ANNUALLY THEREAFTER. 22. AS A MINIMUM REQUIREMENT, ALL DISTURBED AREAS ON AND OFF SITE SHALL BE RETURNED TO THE EQUIVALENT OF THEIR PRECONSTRUCTION CONDITION IN ACCORDANCE WITH APPROPRIATE REQUIREMENTS AND STANDARDS. 23. ALL DISTURBED SOIL AREAS SHALL BE COMPOST AMENDED AND SEEDED OR STABILIZED BY OTHER ACCEPTABLE METHODS FOR THE PREVENTION OF ON - SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. SEE EROSION CONTROL PLANS FOR SPECIFIC GRADING AND EROSION CONTROL REQUIREMENTS. 24. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS CLEAN AT ALL TIMES BY SWEEPING. WASHING OF THESE STREETS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL. 25. THIS PROJECT IS NOT A BALANCED EARTHWORK PROJECT. BOTH EXPORT AND IMPORT OF SOIL AND ROCK MATERIALS ARE REQUIRED. 26. SLOPE OF FINISHED GRADE SHALL BE CONSTANT BETWEEN FINISHED CONTOURS OR SPOT ELEVATIONS SHOWN. 27. FINISHED GRADE SHALL SLOPE AWAY FROM BUILDING WALLS AT MINIMUM 5% SLOPE FOR A MINIMUM DISTANCE OF 10 FEET. 28. CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL INSTALL AND MAINTAIN SHORING AND BRACING AS NECESSARY TO PROTECT WORKERS, EXISTING BUILDINGS, STREETS, WALKWAYS, UTILITIES AND OTHER EXISTING AND PROPOSED IMPROVEMENTS AND EXCAVATIONS AGAINST LOSS OF GROUND OR CAVING EMBANKMENTS. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR REMOVAL OF SHORING AND BRACING, AS REQUIRED. 29. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY AND FOLLOW CITY PROCEDURES FOR ALL WATER SERVICE INTERRUPTIONS, HYDRANT SHUTOFFS, STREET CLOSURES OR OTHER ACCESS RESTRICTIONS. CONTRACTOR SHALL NOT RELOCATE OR ELIMINATE ANY HYDRANTS WITHOUT FIRST OBTAINING WRITTEN APPROVAL FROM THE FIRE MARSHAL. 30. COORDINATE AND ARRANGE FOR ALL UTILITY CONNECTIONS, UTILITY RELOCATIONS AND/OR SERVICE INTERRUPTIONS WITH THE AFFECTED OWNERS AND APPROPRIATE UTILITY COMPANIES. CONNECTIONS TO CONSTRUCTION SEQUENCE NOTES 1. SCHEDULE A PRE -CONSTRUCTION MEETING WITH CITY ENGINEERING DIVISION AT 425-771-0220, EXT. 1326. TWO DAY (48 HR) NOTICE IS REQUIRED. 2. REVIEW TEMPORARY EROSION AND SEDIMENT CONTROL NOTES. 3. CALL FOR UTILITY LOCATES. 4. INSTALL TESC MEASURES AND MAINTAIN DUST CONTROL WHILE PREVENTING DISTURBANCE OF ANY AREAS OF VEGETATION OUTSIDE THE CONSTRUCTION ZONE. 5. HAVE EROSION CONTROL MEASURES INSPECTED BY CITY OF EDMONDS ENGINEERING INSPECTOR. ALL TEMPORARY SEDIMENTATION AND EROSION CONTROL MEASURES MUST BE IN PLACE AND INSPECTED PRIOR TO ANY CONSTRUCTION OR SITE CLEARING. EROSION AND SEDIMENTATION CONTROL PRACTICES AND/OR DEVICES SHALL BE MAINTAINED UNTIL PERMANENT VEGETATION IS ESTABLISHED. 6. DEMOLISH EXISTING STRUCTURES 7. ROUGH GRADE SITE AS REQUIRED TO INSTALL DRAINAGE FEATURES. 8. CLEAR, GRUB & ROUGH GRADE SITE. COMPOST AMEND AND REVEGETATE DISTURBED AREAS NOT SUBJECT TO ADDITIONAL SURFACE DISTURBANCE IMMEDIATELY AFTER ROUGH GRADING. OTHER EXPOSED AREAS SHALL BE STABILIZED PER EROSION CONTROL NOTES BELOW 9. INSTALL UTILITIES AND OTHER SITE IMPROVEMENTS, INCLUDING FRONTAGE IMPROVEMENTS. 10. STABILIZE AND COMPOST AMEND ALL EXPOSED SOILS PRIOR TO REVEGETATION OF ENTIRE SITE. 11. ESTABLISH LANDSCAPING AND PERMANENT VEGETATION. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED UPON FINAL SITE STABILIZATION AND APPROVAL BY CITY INSPECTOR. 12. INSTALL INFILTRATION TRENCH. EXCAVATION OF INFILTRATION AREAS SHALL NOT BE ALLOWED DURING WET OR SATURATED CONDITIONS. THE BMP SHALL NOT BE MADE OPERATIONAL UNTIL ALL EROSION -CAUSING PROJECT IMPROVEMENTS ARE COMPLETED AND ALL EXPOSED GROUND SURFACES ARE STABILIZED. 0 cN Q� N O N N O N U cn O E O C6 O p Z UJ 0 U 00 z� 3 Lu ul O _ U! Z LJJ� W Q V) W J > J a W �1 > N CURB RAMP NOTES O REMOVE U�(2-j INSTALL PER NOT SURVEY PROVIDED BY GEODETIC SURVEYING SERmVICES CEM CONC SIDEWALK CEM CONC SIDEWALK CITY OF EDMONDS, 1, 11 STD DETAIL TR531 jj of(I,/' / OGRADE GROUND TO I �i MATCH NEW CB RIM 385. 77 rROTI� it OI SCALE 1// = 10' 0 0 00 r, 0 CV) T IN 0 Iz J ii o 0 � � WATER Flo Flow METER 2 I oo C: B \CD N II 5.97 ��arN - � iit ., 'SEWER STUB i lE 376;3 \EC.2 (4 w-2d 2 0 " 4 6 ' 99 12' FL.1 86.�CEC.2S9 387,3257 EC.2 4 M EC.2 I 87. 5 16" 12" 10' 1299 387�5 BC.0.2 n9 V gBS. EC.2 14 9 9 BC.2 1 MATCH EX DES a - G.2 �C. A�y 14 9 9 .� BC.1 256 3 89 �88:39 � ,G.2 g9 O C 390.4 XEC - 1.97 1p 3 ._ ,E X393.32 394.4a7 -EC.2 PLUC W/PUNCH 0.44 1. 7, oc CONC CASE 4 4 4 d w394�.46. 4 4 Q. 44 W �4 VISITED J A ' 18 / 1 REPLACE 15 FEE OF W LK I EX. SSM H RN 387.08 CALL �811 NO. 9�DATE BEFORE YOU'DIG PREPARED BY REVISIONS LV� Effective Engineering PLC CIVIL ENGINEERS 8627 NE 180th Street, Bothell, WA 98011 0 (206)259-9902 0 admin@effectiveengineeringpUccom ------------ w n SEC 8, T 27 N, R 4 E, W.M. MATCH EX GRAD 385.97 382.40 N 382.70 �A Co SEWER STUB IE 376.3 Q 5' 10' '. 5 2 SCALE, 1�� 5 '388.21 BC.2 <� Q� C �C 9 7S c'WA 56 0l\' LATCH EX 394.47 EC.2 0 C"I r Crl CD Q0 I I APPROVED FOR CONSTRUCTION ICITY OF EDMONDS I � DATE: I I BY CITY ENGINEERING DIVISION PROJECT: VAISVILA RESIDENCE CLIENT: Richard Vaisvila richa rdva isvi Ia@comcast. net PHONE: 425-299-1739 CURB RAMP PLAN 17125 69TH PL W EDMONDS, WA 98026 ""' 7/21 /2022 SCALE 1 " = 10' DWG CURB RAMP IOB#EE22-70 DRAWN BY BPA APPROVED BPA 7/25/2022 SHEET -1-OF 1