Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED ENG STM PLN RESUB2 BLD2022-0561+Civil_Plan+2.21.2023_4.06.14_PM+3381049
ABBREVIATIONS: ASPH ASPHALT CB CATCH BASIN CL CLASS C7) CLR CLEAR CO CLEAN OUT COMM COMMUNICATION CONIC CONCRETE to 0 5 to 20 CONN CONNECT CMP CORRUGATED METAL PIPE CPEP CORRUGATED POLYETHYLENE PIPE (DOUBLE WALL, SMOOTH INTERIOR) DI DUCTILE IRON 1 inch = 10 ft. DWY DRIVEWAY EOA EDGE OF ASPH ELEV ELEVATION EXST EXISTING FH FIRE HYDRANT FG FINISHED GRADE INV INVERT IE INVERT ELEVATION LEGAL DESCRIPTION IRR IRRIGATION THE WEST 75 FEET OF THE NORTH HALF OF LF LINEAL FEET LOT 2 IN BLOCK 9 OF HANBURY'S SOUND VIEW MB MAILBOX TRACTS AS PER PLAT RECORDED IN VOLUME 7 MON MONUMENT OF PLATS, PAGE 20, RECORDS OF SNOHOMISH COUNTY AUDITOR. NIC NOT IN CONTRACT SITUATE IN THE CITY OF EDMONDS, COUNTY OF NTS NOT TO SCALE SNOHOMISH, STATE OF WASHINGTON. NO NUMBER OHP OVERHEAD POWER VERTICAL DATUM PVMT PAVEMENT ASSUMED P POWERPP POWER POLE SITE BENCH MARK PVC POLYVINYL CHLORIDE GINNIE IN GRAVEL PARKING STRIP R/C REBAR & CAP APPROX 17' EAST OF NW PROPERTY RCP REINFORCED CONIC PIPE CORNER REM REMOVE RET RETAINING ELEVATION: 500' RPM RAISED PAVEMENT MARKER ROW RIGHT-OF-WAY SD STORM DRAIN SF SQUARE FEET SVC SERVICE SS SANITARY SEWER SSS SANITARY SIDE SEWER ST STREET TE TOP ELEVATION TYP TYPICAL W WATER MAIN WM WATER METER POWER: PUD NO. 1 OF SNOHOMISH COUNTY PO BOX 1107 EVERETT, WA 98206-1107 425-670-3216 NATURAL GAS: PUGET SOUND ENERGY 355 110TH AVE NE BELLEVUE, WA 98004 425- 456- 2511 (NOT AVAILABLE TO SITE) WATER & SEWER: I NTE RN ET: XFINITY, ZIPLY FIBER, VIASAT, & HUGHES NET CONTACT: RESEARCH ON LINE SURVEYOR: OWYHEE CONSULTING, LLC 18520 23RD DR SE BOTHELL, WA 98012 206-713-6939 ARBORIST: OLYMPIC VIEW TREE FROG, LLC 8128 228TH ST SW ANDY CROSSETT EDMONDS, WA 98026 PO BOX 307 425- 774- 7769 DU VALL, WA 98019 206-310-8254 PHONE: MULITIPLE PROVIDERS CONTACT: RESEARCH ON LIN SPECIAL NOTES: 1. COVER ALL STOCKPILES WITH PLASTIC SHEETING. 2. FOR ALL CATCH BASINS DRAINING TO INFILTRATION FACILITIES, SEAL GRATES AND PLUG OUTLETS UNTIL SITE IS STABILIZED. 3. WHEELED VEHICLES SHALL NOT TRAVEL OVER INFILTRATION TRENCHES. LIMIT DISTURBANCE IN THOSE AREAS BY ALL EQUIPMENT. 4. MAINTAIN SUPPLIES OF PLASTIC COVERING, SILT FENCE, STRAW MULCH AND OTHER MATERIALS ON SITE TO BE USED AS REQUIRED DURING CONSTRUCTION. 5. TOTAL DISTURBED AREA IS 7,500 SQUARE FEET. 6. FILTER SOCKS WILL BE ADDED TO ANY CATCH BASINS DOWNSTREAM FROM THE CONSTRUCTION SITE. 7. USE ONE OF THE FOLLOWING MATERIALS AS GROUND COVER OVER AREAS TO BE USED FOR PARKING: a. 6-INCH DEPTH OF 2" TO 4" CRUSHED ROCK, GRAVEL BASE OR CRUSHED SURFACING BASE COURSE. b. IF THE AREA IS NOT TO BE USED FOR PERMANENT VEHICLE ACCESS OR PARKING, USE A 6-INCH DEPTH OF HOG FUEL. 8. ALL DISTURBED AREAS TO BE COMPOST AMENDED PER 2014 SWMMWW BMP T5.13. 9. INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO APPROVED PLANS, CITY OF EDMONDS STANDARD DETAILS, AND ALL OTHER MEASURES THAT MAY BE REQUIRED DURING CONSTRUCTION. INDEX TO TESC DETAILS: SILT FENCE: DETAIL ER-900, SHT 3 CONSTRUCTION ENTRANCE: DETAIL ER-901, SHT 3 CB FILTER: DETAIL ER-902, SHT 3 �D CB FILTERS = WM SD PP_ SD SD GAS GAS - 498.80 11 CONC WALK 0 m U z Q w m to w m m 00 0� Oz rnz 0 Oz (Dw -t[Y- 00 O `Y OHP GAS OHP WMc\ SD SD - I � GASGAS GAS GAS: OHH WM GAS GAS CB 3 c� 238TH ST S\�0 3 o O 40 � 3 Cl � V) N89'48'58"E - ; 500.65 • - - - - • 501.56 - 525.09' 499 � 3 C) ' £ 3 4499.36 499.70 5���/� EOA 509.28 EOA 501.13 GRAVEL INV 12" RCP 3 /`. IE 498.7'_ 499.21 / / /' , Wes- W-e� W W W�� W W W W W W` W � OPEN \61TCH EXST 2"SD D 3.94% D VEL ^ SD �- S /D--------I / •- ���-, r SITE BENCH. / IU �� GAVEL GINNIE ASSUMED ----� 2 / 500 WATER ELEV 500' �> > F METER / / b FND 1/2" R/C 0 501.6775.00' • 500.76 y SET 1/2" R/C ZENOVIC LS 280711 ° PAINT I 8/13/20 ° MARK GAS `,5Q0� I x GTC LS 30444 8/13/20 500.13 I I 501.30 EIS • 500 �' • 500.71 ° _1x STOCKPILE AREA / COVER WITHIN 24 USE EXST DWY AS / • 500.22 \ HOURS CONSTRUCTION ACCESS. ADD 0 0 I QUARRY SPALLS PER DETAIL / I I 30" CEDAR = ER-901, AS NECESSARY TO / I I 501.20 I PREVENT TRACKING I ° I a SIDEWALK I 50 .08 I - 771 II I 5 0.73 • 1 16- - - - o I x I I h 1c:GAS I I • 500.20j I METER ° 0 0� EXST H` " I I x 0 0 SILT FENCE & \ I LD Q CLEARING LIMIT I \ SILT FENCE & � ry \ PROPOSED HOUSE I CLEARING LIMIT 0 Lij 0 I �\4 9.84 - .J x 14, 499.6,3 \ I I I 500 22 ( / • • 5 0 35 x Y 0 I \ \ _ _-50050Q 0� = \ \ l I z F _ I REMOVE EXST SSS. SEE����= SEPARATE DEMO PLAN \\ `�sss CD \ J "/ EXPANSION TO 6"SSS -�� • 498.87 498.76 I I • \ � 499 7� - - I / I ° � � PROPOSED SD, TYP ` 499.74 CAP EXST SEWER DURING - - _J SEAL DURING CONSTR CONSTRUCTION WITH A ° STRONGBACK FERNCO WITH ° A SDR35 STUB AND CAP 1 I j X 498.40 11 (MATCH SIZE OF EXISTING). 36" CEDAR ° I MARK CAP LOCATION WITH �- - - - - A 2x4, PAINTED WHITE WITH \ _ _ THE DEPTH OF THE PIPE / X 498_ _ + WRITTEN ON IT. • 4\. ° -------------Q / 49 7 x °X\ ----------Q , o z ]z o z I O z J ,r z X Q 00 o �,Cn tE z MQ • 497.29 I 0 � INSTALL ORANGE BARRIER I g 0 o FENCING AROUND ALL 497,60 • INFILTRATION SYSTEMS 0 0 DURING CONSTRUCTION. I/ 0 0 9_4 9-z"2 8 o x / x \ 498.201- • \ I I 26 FIR i I° o o • 497� o x 496.90 75.00' FND 1/2" R/C 0.00 -X �r-- - - - - iG�-X- if X\ C.00r� MEYRING LS 2621\ N89°49'04"E FND 1/2" R/C 8/13/20 \ WSI LS 16916 00463300900102 8/13/20 COMPLIES WITH APPLICABLE KOREAN UNITED PRESBYTERIAN CHURCH CITY STORM CODE OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE -a 02/27/2023 S W Y41 SEC 31 onn iy nvuae i,nodiIII iy a'! re m ' Fy Family Pancakeca House Edmond_ � CreoitCo:�ceois p 'rn<<ou,•v<i„<�� , 0 TWP 27N RGE 4E 6 23et 238thStSW 238thStSW 8422238thSSW- Edmonds, WA 98026 �2n gate GaryAyers-State nso:nv�F', -�e�- - \ f64 Farm Insurance Agent Q "''ITravelodge by Wyndham United Presb}4eria CTT�'j _ ©Seattle North/Edmonds Church of Seattle 1J 1 1 L_ s s * 111 Edmon�s Way i•'�e=.-��•i©� STFRANCIS Automotive Vision Joyland Preschool and Childcare m vGreat Kids Academy T, O f 240d, St SWdOtfi St SW 4 z40th St SW 2401h St SW /Q 9Panther Road Classics C ar dealer Caravan Outfitter -Rentals Careful Movers \ sW Edmonds Gateway\' 2415191 Apartments ` I Burlington � 9Baby Depot Jeffs Auto Detailing v 242nd St SW 242nd St SW 242nd St SW 242nd St SW Coraz6n D Mexico rSmIn ieelry te - -- 2 -- - IE Volkswagen Scotts Ba~s'Grill /04� J. . 41 9 Certified Pre -Owned 3y'' f ©'' ,w �O g Campbell Nissan VICINITY MAP CONSTRUCTION SEQUENCE NOTES 1. PRECONSTRUCTION MEETINGS SHALL BE REQUESTED VIA ; MYBU I LD I N G PE RM IT AND EMAILED AT ENGINEERINGPERMITS &EDMONDSWA.GOV. TWO DAY (48 HR) NOTICE IS REQUIRED. 2. REVIEW TEMPORARY EROSION AND SEDIMENT CONTROL NOTES. 3. CALL FOR UTILITY LOCATES. 4. INSTALL TESC MEASURES AND MAINTAIN DUST CONTROL WHILE PREVENTING DISTURBANCE OF ANY AREAS OF VEGETATION OUTSIDE THE CONSTRUCTION ZONE. 5. HAVE EROSION CONTROL MEASURES INSPECTED BY CITY OF EDMONDS ENGINEERING INSPECTOR. ALL TEMPORARY SEDIMENTATION AND EROSION CONTROL MEASURES MUST BE IN PLACE AND INSPECTED PRIOR TO ANY CONSTRUCTION OR SITE CLEARING. EROSION AND SEDIMENTATION CONTROL PRACTICES AND/OR DEVICES SHALL BE MAINTAINED UNTIL PERMANENT VEGETATION IS ESTABLISHED. 6. DEMOLISH EXISTING STRUCTURES 7. ROUGH GRADE SITE AS REQUIRED TO INSTALL DRAINAGE FEATURES. 8. CLEAR, GRUB & ROUGH GRADE SITE. COMPOST AMEND AND REVEGETATE DISTURBED AREAS NOT SUBJECT TO ADDITIONAL SURFACE DISTURBANCE IMMEDIATELY AFTER ROUGH GRADING. OTHER EXPOSED AREAS SHALL BE STABILIZED PER EROSION CONTROL NOTES BELOW 9. INSTALL INFILTRATION TRENCH. EXCAVATION OF INFILTRATION AREAS SHALL NOT BE ALLOWED DURING WET OR SATURATED CONDITIONS. THE BMP SHALL NOT BE MADE OPERATIONAL UNTIL ALL EROSION -CAUSING PROJECT IMPROVEMENTS ARE COMPLETED AND ALL EXPOSED GROUND SURFACES ARE STABILIZED. 10. INSTALL UTILITIES AND OTHER SITE IMPROVEM3ENTS, INCLUDING FRONTAGE IMPROVEMENTS. 11. STABILIZE AND COMPOST AMEND ALL EXPOSED SOILS PRIOR TO REVEGETATION OF ENTIRE SITE. 12. ESTABLISH LANDSCAPING AND PERMANENT VEGETATION. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED UPON FINAL SITE STABILIZATION AND APPROVAL BY CITY INSPECTOR. APPROVED BY PLANNING Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. SHEET INDEX: 1 *********** COVER SHEET & TESC PLAN 2 *********** GRADING & DRAINAGE PLAN 3 *********** DETAILS 4 *********** NOTES & W-S DETAILS BLD2022-0561 RESUB 2/21 /2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE:------3/28/2023 ---------------- BY: ------------------------------------ CITY ENGINEERING DIVISION Mar 07 2023 Know what's below. C111 before you dig. PARCEL NO: 00463300900200 zL,4 SW Y4, SEC 31, TWP 27N, RGE 4E ,IN►> 10 05 10 20 RESTORATION LIMITS TO BE DETERMINED BY CITY ENGINEERING INSPECTOR Utility patches shall be combined and full width or half width overlay will be required depending on the extent of disturbance. Where utility patches fall entirely within one travel lane, the overlay shall extend to the centerline of roadway. Where utility patches extend into both travel lanes then a full width overlay is required. WM WM ` SD I JI INFILTRATION TRENCH DATA OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY (ALL 4' WIDE) UTILITIES MAY REQUIRE A SEPERATE PERMIT. TRENCH LENGTH PIPE NO. INVERT 1Q 26' 497,15 Q2 48' 496.8 Q3 47' 496.60 CB / SPECIAL NOTES / CB CONC \BALK 1. INFILTRATION SYSTEM OVERFLOW IS TO CB#0-2. SET OVERFLOW /SD PIPE EXTENDING TO THAT CB PER PLAN. INVERT OF 11 Y4* TEE / SHALL BE SET HIGHER THAN THE TEE AT THE CONNECTION TO THE / ROOF DRAIN SYSTEM, AS SHOWN ON THIS PLAN. 2. PERMEABLE DRIVEWAY SURFACES SHALL NOT EXCEED 6% (PER CB CITY OF EDMONDS AND DOE REQUIREMENTS) AND SHALL MEET TYPE RIM-41 CB MANUFACTURER'S SPECIFICATIONS. 95.33 12" RCP IE-491.68 3, OVWSD WILL REMOVE EXISTING WM AND SERVICE AND INSTALL NEW 1-INCH WM & SERVICE AT OWNER'S EXPENSE. BACK OF WM SHALL BE ON THE PROPERTY LINE. OWNER SHALL INSTALL 1.5" TYPE K MAY BE REUSED IF COPPER SERVICE WITH A TRACER WIRE FROM WM TO HOUSE. SEPARATION 4. PROVIDE A MINIMUM OF 3 FEET HORIZONTAL SEPARATION BETWEEN REQUIREMENTS CAN BEACHIEVE THE WATER AND DRY UTILITIES (POWER, GAS, ETC.) AND 10 FEET BETWEEN WATER AND SEWER. PROVIDE 5 FEET HORIZONTAL 4" ROOF DRAIN SEPARATION TO CITY MAIN LINES. PROVIDE 1 FOOT VERTICAL TO SEPARATION BETWEEN DRY UTILITIES AND SEWER, WATER, AND CB#0-2 STORM. �1.8' 5. UNDERGROUND WIRING REQUIREMENTS OF ECDC 18.05 SHALL BE FOLLOWED. ALL UTILITY SERVICES SHALL BE INSTALLED UNDERGROUND. 11 1 /4* BEND 6, TYPE 1 CB SHALL PROVIDE 1.5' MINIMUM BETWEEN OUTLET INVERT IE=498.6 AND BOTTOM OF STRUCTURE. 4" TEE IE=498.33 10 7. PERFORATED PVC PIPE SHALL MEET THE REQUIREMENTS OF ASTM D 2729. SOLID WALL PIPE IN PRIVATE PROPERTY SHALL BE PVC MEETING ASTM D 1784, MINIMUM WALL THICKNESS 0.120 INCHES AND IN THE ROW SHALL BE 0.150 INCHES. WHERE PIPE MATERIAL IS NOT SPECIFIED - ACCEPTABLE TIGHTLINE MATERIAL: SDR 35 SCH 40 INFILTRATION TRENCH SIZING N-12 F810 HANCOR SOIL TYPE: LOAMY SAND ROOF AREA: 3224 SF REQ'D 2' WIDE TRENCH: 75LF/1000SF, OR 150SF/1000SF TOTAL 2' WIDE TRENCH AREA REQUIRED: 150(3224/1000)=484SF TOTAL 4' WIDE TRENCH LENGTH REQUIRED: (484/4)=121 LF TRENCH LENGTH PROVIDED: 121 LF INF INFILTRATION PIT TP TEST PIT IMPERVIOUS AREAS CHART PROJECT SITE CATEGORY: CATEGORY 1 DISCHARGE LOCATION: FULLY INFILTRATED. OVERFLOW SHEET FLOWS OFF OF THE SITE AND THEN DRAINS THROUGH THE "EDMONDS WAY" WATERSHED. TYPE OF AREA SQUARE FOOTAGE STORMWATER FACILITY LAWN & LANDSCAPE 6911 SF COMPOSTING PER T5.13 ROOFS 3224 SF INFILTRATION TRENCH HARD SURFACE 1119 SF PERMEABLE CONC PVMT FINAL LOCATION OF UNDERGROUND UTILITIES TO BE DETERMINED UNDER SEPARATE PERMIT/PLANS WITH RESPECTIVE UTILITY COMPANIES. - -PP ------ - - - P OHP - P - - m WM __- P ,'I -I CB OHP- GAS GAS WM 3 GAS CB 3 OVWSD SEW 1 3 UNDERGROUND POWER & MAIN IS LOCHWITHIN 238T1 ��COMM &GAS 1F EXST SVC I NOT USED (COMMON TRENCSW.CONTRA H) 3 CONT SI u� �u N89'48'58"E - - 500.65 • - - - - • 501.56 FOR LOCATIP _ _ UTILITIES. 525.09' 4999� MATCH EXST GRADE 3 z" TYPE 1 CB#0-1 O NOW OSLOPE ( ) NEW DWY PER STD TE=499.51 DETAIL TR-546 3 IE=496.30*(12") SEE SPECIAL NOTE 3 8� 0 500.68(EXST) 501.13 IE=496.80(6) STD DETAIL W-1A SHT 4 *VERIFY PRIOR TO �,,J 499.70 �' EOA 509.28 EOA CONSTR ............ ......... . o ....... /.............. .......... .......... G� INV 12" RCP /.......... o E 498 Z'- ............. .................. w_WI w w. w . ......w .. CONC WALK EXST 2"SD @ 3.94% �, ; 6 w �' OPENITCH ✓ 1VEL SD SD SD S D......... i - ....... l t . i 5 0`8... . .. 9 RESHAPE SLOPE � ... RESHAPE i SITE BENCH. ++ / 0 G V AT 2H: 1 V GINNIE ASSUMED----�-� 1OLF 6 SD 27'.. ELEV 500' 1 ` �� i 0 1.0% � WATER ro ` 00.75 METER FND 1 2" R C _ • JU I. / T .. :_ ; : _ G� - - - - / / 75.00' 'D .. 500..76 .. ZENOVIC LS 280711 � ° �) PAINT .• � ,- ,� � . ' I SET 1/2" R/C g /1 3 /20 I M ARK GAS 500.5 0�. : - j I X GTC LS 30444 8/13/20 ,E) CB#0-2(TYPE 1) I i 00.13 �.,5 TE=501.22 I • 500.89 P 501;,30 PERMEABLE SURFACING IE=497.07(ALL 4) l (ALL UNROOFED IE=496.90(6") - 4" SD. CONN IMPERVIOUS SURFACES). SEE DETAIL. GRADE TO USE EXST GAS / FTG DRAINS DRAIN AS SHOWN. IF ADEQUATE • 500.22 IE=497.31 " PER PSE STDs I I 30" CEDAR \ 21 LF 4 SD @ 7.29% I I 0. 50.0:55.5 01;. z . SEE SPECIAL 0 NOTE#1I - IE- SURFACE FLOW 498.44c ° 500.4 PATH, TYP I EXST 1 I a f I I 5 0 7-- / III / r 01 0 CONNECTION TO OLYMPIC VIEW WATER AN I Gas Y - 501.0 EST/ I SEWER DISTRICT (OVWSD) SEWER MAIN. I • 500.20� METER 1 / -_ - / APPROVAL BY OVWSD REQUIRED. ISSUANC OF ° THIS PERMIT DOES NOT CONSTITUTE PERMISSION TO WORK ON ANY PROPERTY GARAGE X I FF: 501.0 OTHER THAN THAT OWNED BY THE SUBJEC 5005 �\ i ,ST F / i I PROPERTY OWNER. DOWNSPOUT, TYP / I � � 1 ---- IV -- -----� I 4"SD @ 1.0% MIN I 1 \,0 499.8� O U S E IIE=498. 1 \ 401 .6 OT TP 1 \ FF: 501.0 I I I 4"SD @ I500.22(� I I 1.0% MIN i 1 • • i I • 5 (� 5 X z 50 0 -0-2- - o 1 1 - -500- cP o \� \ I I w X o � s� I I Q ----------------- I I I CO TO EXST 6" SSS. Q I X 1 496.27 SURFACE RUNOFF PRE AND 1 / / �� 1 1500.1 ( I 499.5 IE=497.41 I POST DEVELOPMENT), TYP / 499.3 EXST. / 499.50 SSS IE=496.61 CO EXPANSION TO 6"SSS 61 o I i ° d. 49.8:8 .. .:7. / I 4 E �497.67 I PORCH 6"PVC, ASTM 3034, ° ROOF ° SDR 35 @ 2% MIN. COs ° ° � ° CB#1(TYPE 1) 499.74 • 498.5 I <;/ SHALL BE 6" PER STD EX T i 499.2 TE=498.9 _ DETAILS 3, SHT 4 °--:- IE=497.28 SURFACE RUNOFF. Q1 • 498 4C 3% MIN WITHIN 10 i 36" CEDAR C----CO FEET OF HOUSE I O-----� I STEP DOWN \\ SEE DETAIL �2 �I \ CO • 49�. ;�2\ ------ SD SD S�J SD SD - GAS GAS GAS GAS - GAS GAS GAS= i i i Cl � i EXST GRAVEL TO REMAIN. 238TH ST S\► REMOVE BALANCE OF o0 GRAVEL IN ROW & REPLACE WITH GRASS. D MATCH TRENCH PIPE DIA. STEP DOWN DETAIL NTS pR1TF Rod OAFRry FAW MKIICurn nownr 'ILTRATION TRENCH E DETAIL q ARO 'OR qTF �Fo 0 BY c rygSN ITF ROB OpFRry DRIVEWAY APPROACH (WITHOUT CUR O SAWCUT EDGE o 55 Uj Fr 0 EXISTING ASPHALT a_ Of STREET VARIES \ 2" HMA 2O 2"-5/8" MINUS CSTC COMPACTED SUBGRADE O SECTION A -A RESUB 2/21 /2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT NOTES: Ol SAWCUT AND USE TACK COAT BETWEEN ROAD TO DRIVEWAY APPROACH JOINT. SEAL JOINT WITH AR4000 SEALER. O DRIVEWAY APPROACH TO BE 2" HMA CLASS 1 /2" PG 58H-22. O SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DENSITY. O 10' EDGE RADIUS. O HMA SHALL BE PLACED FROM EDGE OF EXISTING STREET, A MINIMUM DISTANCE OF 20-FT OR TO PROPERTY LINE, WHICHEVER IS GREATER. `St. IB' - CITY OF EDMONDS PUBLIC WORKS DEPARTMENT I \ \ _4 .97 7 X CO ALL RESTORATION WORK IN THE 238TH 6.3'J 7•7' I ST ROW SHALL BE DONE BY THE Q CONTRACTOR AND NOT THE CITY OF I X z EDMONDS. CO --------- ------- ,CO I o _ o z OBSERVATION U' Cl WELL, TYP o o _ - � z • 497.29 • 497.41 I o I � INE 497.60 • I o O I I/ 9_49�28 X I 498.20�' • 1 I 26„ FIR i I I 0 • 497�_ X 496. • �� I s 75.00, 41 z _ _ FIND 1/2" R/C � �`X +" � Cov� FINDMEYING1/2 LS 2621\ N89°49'04"E FIND 1/2" R/C 8/13/20 \ NATURAL DISPERSED RUNOFF WSI LS 16916 / PATTERN TO REMAIN 8/13/20 ENGINEERING DIVISION APPROVED AS NOTED 03/28/2023 DRIVEWAY APPROACH TYPE VI APPROVED BY: R. ENGLISH Know what's below. Call before you dig. REVISION DATE JUNE 2021 STANDARD DETAIL TR-546 Z. G , D , 5�,4 4r was u 18 2�9 5- �AL�'1V6' D SITE DEVELOPMENT SERVICES 3011 RAVEN CREST BELLINGHAM, WA 98226 (425) 481-9687 DAVESDS49@GMAIL.COM 2" x 2" WOOD/STEEL FILTER FABRIC SECURED TO 2" x 2" 14 GA WIRE FABRIC EQUAL 0 I N NATIVE BACKFILL MATERIAL FILTER FABRIC MATERIAL IN CONTINOUS ROLLS USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO WIRE 2" x 2" WOOD/STEEL POSTS -\ WIRE MESH FENCE TO SUPPORT FILTER �I FABRIC co BURY BOTTOM OF FILTER N MATERIAL 8" TO 12" 6' MAX NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER EROSION CONTROL THROUGHOUT PROJECT. 2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION ACTIVITY. CITY OF EDMONDS PUBLIC WORKS DEPARTMENT CITY OF EDMONDS PUBLIC WORKS DEPARTMENT CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN REVISION DATE FILTER FABRIC FENCE JANUARY 2018 FILTRATION SYSTEMS STANDARD DETAIL APPROVED BY: R. ENGLISH E R- 9 0 0 CATCH BASIN GRATE FILTER SOCK WITH OVER FLOW HOLES (TYP) CATCH BASIN NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN THIS APPLICATION AT ALL TIMES DURING CONSTRUCTION PERIOD. 2. ANY SEDIMENT IN CATCH BASIN INSERT SHALL BE REMOVED WHEN INSERT IS ONE-THIRD FULL. 3. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN. TEMPORARY SEDIMENT TRAP FOR CATCH BASINS APPROVED BY: R. ENGLISH REVISION DATE JANUARY 2018 STANDARD D ETAI L ER-902 _LS A TH IN DE FULL WIDTH GRESS/EGRESS DETAIL NOTES: O THE MINIMUM LENGTH SHALL BE EXTENDED AS NECESSARY TO ENSURE MATERIAL IS NOT TRACKED OFF SITE AND/OR INTO THE PUBLIC RIGHT-OF-WAY. (� ATB DRIVEWAY RAMP AND/OR SITE ACCESS ROAD 15' WIDE MIN. SEE TABLE BELOW FOR REQUIRED LENGTH. NOTES: 1. SURFACE WATER - ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCES SHALL BE PIPED ACROSS THE ENTRANCE. IF PIPING IS IMPRACTICAL, A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMITTED. 2. MAINTENANCE - THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL QUARRY SPALLS AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY MUST BE REMOVED IMMEDIATELY. 3. WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO LEAVING THE SITE. WHEN WASHING IS USED, IT SHALL BE DONE ON AN AREA STABILIZED WITH QUARRY SPALLS AND WHICH DRAINS INTO AN APPROVED SEDIMENT TRAPPING DEVICE. 4. INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN. PROJECT SIZE MIN LENGTH OF (FEET) QUARRY SPALLS* < 1/4 ACRE 30 < 1 ACRE 50 < 3 ACRE 100 > 3 ACRE 100 :J * PROVIDE ATB OR ASPHALT TRANSITION WHERE FRONTAGE ROAD IS AN ARTERIAL. LENGTH TO BE DETERMINED BY CITY INSPECTOR. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN REVISION DATE CITY OF EDMONDS STABILIZED CONSTRUCTION JANUARY 2018 PUBLIC WORKS ENTRANCE STANDARD DEPARTMENT DETAIL FS t . 18APPROVED BY: R. ENGLISH ER - 9 01 4" (MIN) 6" (MIN) 6" (MIN) 1' (MIN) ABOVE SEASONAL HIGH GROUNDWATER TABLE OR HYDRAULICALLY RESTRICTIVE LAYER °°°°°°°°°°°°°°°°°°° - PERVIOUS CONCRETE, SEE NOTE 1 0000000000000000000 PERMEABLE BALLAST, SEE NOTES 2 & 3 RUNOFF TREATMENT LAYER (IF REQUIRED PER EDMONDS STORMWATER CODE), SEE NOTE 4 SUBGRADE, SEE NOTE 5 GENERAL NOTES: 1. REFER TO THE 2017 CITY OF EDMONDS STORMWATER ADDENDUM FOR SETBACK (CHECKLIST 11) AND INFEASIBILITY REQUIREMENTS. 2. THE MINIMUM THICKNESS SHOWN ABOVE MAY NOT BE SUFFICIENT FOR ALL APPLICATIONS. A PROJECT SPECIFIC PAVEMENT DESIGN SHALL BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON IN CIVIL ENGINEERING TO: 2.1. SUPPORT THE ANTICIPATED LOADING (E.G. PAVEMENT DESIGN LIFE, INITIAL AND TERMINAL SERVICEABILITY, RELIABILITY, ETC.) AND 2.2. TO SATISFY THE HYDROLOGIC REQUIREMENTS OF THE CITY OF EDMONDS STORMWATER CODE (I.E., CODE MAY WARRANT A THICKER PAVEMENT SECTION THAN THE MINIMUM STRUCTURAL SECTION REQUIRED). 3. FOR SUBGRADE SLOPES 3% OR GREATER, SUBSURFACE CHECK DAMS OR OTHER METHODS TO PROMOTE SUBSURFACE PONDING ARE REQUIRED. 4. GEOTEXTILE SHALL NOT BE USED IN PAVEMENT SECTION UNLESS REQUIRED BY GEOTECHNICAL ENGINEER. IF REQUIRED, GEOTEXTILE SHALL CONFORM TO WSDOT 9.33.2(1) GEOTEXTILE FOR SEPARATION, WOVEN TYPE. 5.^T REFER TO WSDOT LOCAL AGENCY GSPs DIVISIONS 2-9 FOR APWA GSPs. 1. PERVIOUS CONCRETE SHALL CONFORM TO REQUIREMENTS OF APWA GSP 5-06SA. SURFACE SLOPE SHALL BE BETWEEN 0.5% AND 10%. 2. PERMEABLE BALLAST SHALL CONFORM TO THE REQUIREMENTS OF APWA GSP 4-04.2(9-03.9(2)).OPT1. 3. PAVEMENT BASE SHALL BE INSTALLED PER APWA GSP 4-04.3(5) SHAPING AND COMPACTION. 4. RUNOFF TREATMENT LAYER SHALL MEET THE REQUIREMENTS OF 2017 CITY OF EDMONDS STORMWATER ADDENDUM. 5. PREPARE AND PROTECT SUBGRADE PER APWA GSP 2-06.3(3) SUBGRADE FOR PERMEABLE PAVEMENTS. `St. 18`3v CITY OF EDMONDS PUBLIC WORKS DEPARTMENT TYPICAL PERVIOUS CONCRETE PAVEMENT APPROVED BY: R. ENGLISH REVISION DATE DECEMBER 2017 STANDARD DETAIL SD-622 RESUB 2/21 /2023 CITY OF EDMONDS DEVgTy FENCES VICES DEPARTMENT Control pedestrian and vehicle traffic around temporary hazards. �C 7� �CA''- °'••••`•". •.`-•'���-• -;- • Recommended for construction sites, parking lots or y111, qµ- n., a..v._._, �•e�,�sssr �".'yo a .: T. -.,�w .. .. ' warehouses. son iNW, ab014 low S40�a!!lO�l�ire�e� ��aa�o..�......:::� ::: .._ ,,���► ++�•��.„�,'_..,,,,... '..; •Easy to install and remove. Rolls up for easy �+ W490040pi�s�•�.•���',a,o:�e'° .. transport. . ap d,e�s�W0�� ��,,VwPdo40 ww�:'- ; . r ". Heavy Duty Fences - 50% stronger for windy, snowy .� 19_�.P �! a� r'i► ; 5• tee?.`^ p� oar_ p+t�•��� - winter conditions. • L�lvv •, -,.M •• ,r (p;?.." f , »,; • Fence Posts - Sturdy painted steel for in -ground use. •0 Heavy duty posts withstand strong winds. Sold _�; "� �_�,? �• .� '. separately. SAFETY FENCES Orange Green Black Yellow UNDERDRAIN PIPE w Z� JZI W M Of N 5' o(MIN) a_ - - INFILTRATION TRENCH EXTENTS 6" Ae' (MIN) DIA. OBSERVATION WELLS SPACED 25' APART (MAX), 1 WELL (MIN) PER TRENCH MODEL DESCRIPTI NO. S-14713 Standal S-22226 Heavy D S-24123 Standal S-24124 I Heavy D, ON SIZE H x L THICKNESS (MIL) WEIGHT PRICE EACH ADD TO CART 1 3 1 12+ d $42 $41 $40 Specify Color 10 11 4 x 100' I l Jty 20 13 50 49 48 J Specify Color 10 26 135 Specify Color d 140 138 6 x 100' sty 20 31 155 153 150 Speci Color GREEN STEEL POSTS FOR SAFETY FENCE MODEL PRICE EACH wn.>> ADD TO NO DESCRIPTION SIZE FOR USE WITH �� CART 3 12 24+ H-4637 Standard 3 $13 $12 $11 � ADD H-9484 Heavy Duty Heavy Duty 6' 8' 4' Tall Fence 8 14 13 12 [3---IF ADD & Tall Fence 10 16 15 14 3� FADD H-9310 ORANGE BARRIER FENCE INSTALL GRATE FOR OVERFLOW TYPE 1 OR 1-LJCATCH - I D BASIN W/ SO4&-E PER GUTTER CITY STANDARD DETAIL SD-303 OR SD-304 ----� --� 4 5' (MIN) ' z 10' (MIN) in � t PROPERTY LINE/EASEMENT OF - - -PLAN Ro NTS V�jROOF DOWNSPOUT ENGINEERING DIVISION APPROVED AS NOTED 03/28/2023 CLEANOUT 12" BUILDING 12" =1 =1J1==111-111=1ll = I 1=1LI- - 1L= MIN Z. 1-:3 : 4" (MIN) PVC DRAIN D .......................................... 6" (MIN) PIPE PER WSDOT 4 WAS LEVEL J SPEC. 9-05.1(5), 12" (MIN) MAINTAIN POSITIVE 6" U SLOPE X (MIN) PERFORATED PVC REMOVABLE PUSH -ON PVC TEE UNDERDRAIN PIPE PER WSDOT PVC DRAIN PIPE SPEC. 9-05.2(6), LAID LEVEL R 182 100' (MAX) FGISIER� PROFILE GENERAL NOTES: Slol`AL�� PLASTIC BOX NTS MARKED "DRAIN" 1. REFER TO THE 2017 CITY OF EDMONDS TEST PLUG STORMWATER ADDENDUM FOR SETBACK II=III I II 6" (MIN) (CHECKLIST 13) AND INFEASIBILITY REQUIREMENTS. D -IT_I- I I -III -I OBSERVATION II -III II -III 1T(= ,BACKFIELD 2. MIN COVER DEPTHS ASSUME NO VEHICULAR , WELL, SEE NOTE 3 LOADING. DESIGNER TO SPECIFY COVER DEPTHS IF VEHICULAR TRAFFIC ANTICIPATED. SITE DEVELOPMENT SERVIC WASHED DRAIN O Know what's below. 3011 RAVEN CREST ROCK, SEE Z BELLINGHAM, WA 9822 NOTE 2 �� � N OTES: Call before you dig. (425) 481-9687 GEOTEXTILE, �D N Z 00 DAVESDS49@GMAIL.CO C= O = 1. PLACE GEOTEXTILE FABRIC ALONG WALLS AND TOP SEE NOTE 1 0O QO�` OF WASHED ROCK. GEOTEXTILE SHALL CONFORM TO U WSDOT1' (MIN) SEP RATION, NON -WOVEN TYPEEXTILE FOR -2' (MIN) ABOVE SEASONAL 2. WASHED DRAIN ROCK SHALL CONFORM TO WSDOT UNCOMPACTED NATIVE - 2/17/23 REVISED PER CITY COMMENTS - HIGH SPEC. 9-03.12(5), GRAVEL BACKFILL FOR DRYWELLS. MATERIAL, SCARIFY 3" - GROUNDWATER (MIN) TABLE OR 3. OBSERVATION WELL SHALL CONFORM TO WSDOT 10/10/22 REVISED PER CITY COMMENTS SECTION q HYDRAULICALLY SPEC. 9-05.2(6), PERFORATED PVC UNDERDRAIN NTS RESTRICTIVEPIPE. SHARMA RFSTDFNC IF `St. 1sL3" REVISION DATE CITY OF EDMONDS TYPICAL DOWNSPOUT APRIL 2021 INFILTRATION TRENCH PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH S D - 63 6 D. E. F. G. NOTES: 1. REFER TO OVWSD APPROVED MATERIALS LIST FOR MATERIALS TO BE USED. 2. PROVIDE BLOCK OUT FOR METER BOXES IN DRIVEWAYS. PREAPPROVAL REQUIRED. SEE DWG W-14 METER TO BE SUPPLIED AND INSTALLED BY DISTRICT. METER AND SETTER TO BE CENTERED VERTICALLY & HORIZONTALLY IN BOX. CONNECT TO PRIVATE SERVICE. DESCRIP11OO1 SERVICE SADDLE 1" CORPORATION STOP 1" COPPER TUBING COPPER METER SETTER METER BOX COMP. x COUPLING (HORIZONTAL OR VERTICAL INLET) INSTALL BURIED METALLIC MARKER TAPE. TAPE SHOULD READ "CAUTION BURIED WATER BELOW". CARLTON INDUSTRIES INC., BLACKBURN MFG. CO. OR EQUAL. OLYMPIC VIEW WATER & SEWER DISTRICT REVISIONS STANDARD DETAIL WATER METER AND I -INCH SERVICE C❑NNECTI❑N DETAIL DATE SCALE DWG NO. 11 /29 /21 N TS W-1 A Lv Z H J BUILDING BUILDING I w CLEANOUT NOT I o TO EXCEED 3FT FROM CLEANOUT WITH 451 FOUNDATION „BEND AND CAP GENERAL CLEANOUL:� NOT TO EXCEED 100' BETWEEN CLEANOUTS j 12" ASPHALT SURFACE _ 6" RISER 12" PVC SLEEVE PVC CAP. REMOVE GASKET PRIOR TO INSTALLATION. TYPICAL CLEANOUT UNDER ASPHALT 110LYMPIC VIEW Z Lv w V) CLEANOUT (WYE W/ CAP & LAMPHOLE COVER) 12" LAMPHOLE COVER Lua TO MATCH EXISTING o Z GRADE Uf -I a -i 12" PVC SLEEVE 6" RISER 6" WYE AND 45' BEND -6" DISTRICT STUB 4" OR 6" SIDE SEWER CLEANOUT DETAIL AT PROPERTY LINE & BUILDING LAMPHOLE COVER ° ao°o° NOTE: SIDE SEWER JOINTS SHALL BE GASKETED OLYMPIC VIEW WATER & SEWER DISTRICT REVISIONS STANDARD DETAIL SEWER CLEANOUT DETAIL DATE SCALE DWG NO. 11 /18/21 NTS S-3 TREE PROTECTION NOTES Prior to development activity or initiating tree removal on the site, vegetated areas, individual trees and soil to be preserved in accordance with ECDC 23.10.060(B) shall be protected from potentially damaging activities pursuant to the following standards: A. Preconstruction Meeting Required. Prior to the commencement of any permitted clearing and grading activity, a preconstruction meeting shall be held on site with the permittee and appropriate city staff. The project site shall be marked in the field as follows: 1. The extent of clearing and grading to occur; 2. Delineation and protection of any critical areas and critical area buffers with clearing limit fencing; 3. Flagging of trees to be removed and tags on trees to be retained; and 4. Property lines. B. Placing Materials Near Trees. No person may conduct any activity within the protected area of any tree designated to remain, including, but not limited to, operating or parking equipment, placing solvents, storing building material or stockpiling any materials, or dumping concrete washout or other chemicals. During construction, no person shall attach any object to any tree designated for protection. C. Protective Barrier. Before development, land clearing, grading, filling or any land alteration, the applicant shall: 1. Erect and maintain readily visible temporary protective tree fencing along the limits of disturbance which completely surrounds the protected area of all retained trees, groups of trees, vegetation and native soil. Tree protective fencing shall be a minimum height of three feet, visible and of durable construction; orange polyethylene laminar fencing is acceptable. 2. Install highly visible signs spaced no further than 15 feet apart along the entirety of the protective tree fencing. Said sign must be approved by the director and shall state, at a minimum, "Tree and Soil Protection Area, Entrance Prohibited," and provide the city phone number for code enforcement to report violations. 3. Prohibit excavation or compaction of soil or other potentially damaging activities within the barriers; provided, that the director may allow such activities approved by a qualified professional and under the supervision of a qualified professional retained and paid for by the applicant. 4. Maintain the protective barriers in place for the duration of the project until the director authorizes their removal. 5. Ensure that any approved landscaping done in the protected zone subsequent to the removal of the barriers shall be accomplished with machinery from outside the protected zone or by hand. 6. Limit the time period that the critical root zone is covered by mulch, plywood, steel plates or similar materials, or by light soils, to protect the tree's critical root zone. 7. In addition to the above, the director may require the following: a. If equipment is authorized to operate within the protected zone, the soil and critical root zone of a tree must be covered with mulch to a depth of at least six inches or with plywood, steel plates or similar material in order to protect roots and soil from damage caused by heavy equipment. b. Minimize root damage by hand -excavating a two -foot -deep trench, at edge of critical root zone, to cleanly sever the roots of trees to be retained. Never rip or shred roots with heavy equipment. c. Corrective pruning performed on protected trees in order to avoid damage from machinery or building activity. d. Maintenance of trees throughout construction period by watering and fertilizing. D. Grade. 1. The grade shall not be elevated or reduced within the critical root zone of trees to be preserved without the director's authorization based on recommendations from a qualified professional. The director may allow coverage of up to one-half of the area of the tree's critical root zone with light soils (no clay) to the minimum depth necessary to carry out grading or landscaping plans, if it will not imperil the survival of the tree. Aeration devices may be required to ensure the tree's survival. 2. If the grade adjacent to a preserved tree is raised such that it could slough or erode into the tree's critical root zone, it shall be permanently stabilized to prevent soil erosion and suffocation of the roots. 3. The applicant shall not install an impervious surface within the critical root zone of any tree to be retained without the authorization of the director. The director may require specific construction methods and/or use of aeration devices to ensure the tree's survival and to minimize the potential for root -induced damage to the impervious surface. 4. To the greatest extent practical, utility trenches shall be located outside of the critical root zone of trees to be retained. The director may require that utilities be tunneled under the roots of trees to be retained if the director determines that trenching would significantly reduce the chances of the tree's survival. 5. Trees and other vegetation to be retained shall be protected from erosion and sedimentation. Clearing operations shall be conducted so as to expose the smallest practical area of soil to erosion for the least possible time. To control erosion, it is encouraged that shrubs, ground cover and stumps be maintained on the individual lots, where feasible. 6. The director may approve the use of alternative tree protection techniques if those techniques provide an equal or greater degree of protection than the techniques listed in this subsection. TREE PROTECTION NOTES, CONT'D E. Directional Felling. Directional felling of trees shall be used to avoid damage to trees designated for retention. F. Additional Requirements. The director may require additional tree protection measures that are consistent with accepted urban forestry industry practices. [Ord. 4227 § 1 (Att. A), 2021; Ord. 4�IES U B (Att. A), 2021; Ord. 4218 § 1 (Att. A), 2021]. 2/21 /2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GENERAL NOTES 1. ALL MATERIALS AND WORK SHOWN ON THESE PLANS SHALL CONFORM TO THE CITY OF EDMONDS STANDARD PLANS AND DETAILS, THE FOLLOWING SPECIFICATIONS AND CODES, AND ALL OTHER APPLICABLE LOCAL MUNICIPAL, STATE, AND FEDERAL CODES, RULES AND REGULATIONS: - CURRENT INTERNATIONAL BUILDING CODE (IBC) - 2022 WSDOT/APWA STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION - WASHINGTON STATE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN (CURRENT EDITION) 2. STANDARD PLAN AND TYPE NUMBERS INDICATED ON THESE DRAWINGS REFER TO CITY OF EDMONDS STANDARD DETAILS, UNLESS NOTED OTHERWISE 3. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOBSITE WHENEVER CONSTRUCTION IS IN PROGRESS. 4. DEVIATIONS FROM THESE PLANS MUST BE APPROVED BY THE ENGINEER OF RECORD AND THE LOCAL GOVERNING AUTHORITY. 5. CONTRACTOR SHALL RECORD ALL APPROVED DEVIATIONS FROM THESE PLANS ON A SET OF "AS -BUILT" DRAWINGS AND SHALL SUMMARIZE ALL AS - BUILT CONDITIONS ON ONE SET OF REPRODUCIBLE DRAWINGS FOR SUBMITTAL TO THE OWNER PRIOR PROJECT COMPLETION AND ACCEPTANCE. A SET OF AS -BUILT DRAWINGS SHALL BE SUBMITTED TO THE CITY OF EDMONDS PRIOR TO FINAL APPROVAL OF THE BUILDING OCCUPANCY/FINAL PROJECT APPROVAL. 6. ELEVATIONS SHOWN ARE IN FEET. SEE SURVEY FOR BENCHMARK INFORMATION. 7. THE LOCATIONS OF EXISTING UTILITIES AND SITE FEATURES SHOWN HEREON HAVE BEEN FURNISHED BY OTHERS BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND PROTECT ANY OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. CONTRACTOR SHALL VERIFY LOCATION, DEPTH, SIZE, TYPE AND CONDITION OF EXISTING UTILITY LINES AT CONNECTION OR CROSSING POINTS BEFORE TRENCHING FOR NEW UTILITIES. ENGINEER ASSUMES NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF THE EXISTING UTILITIES AND SITE FEATURES PRESENTED ON THESE DRAWINGS. ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF CONFLICTS THAT ARISE. 8. CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING CONSTRUCTION AND SHALL CONTACT THE UNDERGROUND UTILITIES LOCATION SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. 9. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE PROJECT SITE BEFORE STARTING WORK AND SHALL NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES. 10. PIPE LENGTHS WHERE SHOWN ARE APPROXIMATE AND MAY CHANGE DUE TO FIELD CONDITIONS. 11. CONTRACTOR SHALL OBTAIN A COPY OF THE GEOTECHNICAL REPORT (WHERE APPLICABLE) AND SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE CONTENTS THEREOF. ALL SITE WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH THE RECOMMENDATIONS OF THIS REPORT. 12. STRUCTURAL FILL MATERIAL AND PLACEMENT SHALL CONFORM TO THE RECOMMENDATIONS OF THE PROJECT GEOTECHNICAL REPORT. 13. SUBGRADE SOILS IN ALL AREAS WHERE RAIN GARDENS, INFILTRATION OR PERVIOUS PAVEMENT IS TO BE PLACED SHALL BE DELINEATED AND PROTECTED AT ALL TIMES FROM COMPACTIVE ACTIVITIES (i.e. HEAVY EQUIPMENT, STOCKPILING). 14. MANHOLES, CATCH BASINS, UTILITIES AND PAVEMENT SHALL BEAR ON MEDIUM DENSE TO VERY DENSE NATIVE SOIL OR COMPACTED STRUCTURAL FILL. IF SOIL IS DISTURBED, SOFT, LOOSE, WET OR IF ORGANIC MATERIAL IS PRESENT AT SUBGRADE ELEVATION, REMOVE AND REPLACE WITH COMPACTED STRUCTURAL FILL PER GEOTECHNICAL REPORT. 15. SEE SURVEY AND ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND LOCATIONS OF BUILDINGS, LANDSCAPED AREAS AND OTHER PROPOSED OR EXISTING SITE FEATURES. 16. SEE ARCHITECTURAL DRAWINGS FOR PERIMETER FOUNDATION DRAINS. FOUNDATION DRAINS SHALL BE INDEPENDENT OF OTHER SITE DRAIN LINES AND SHALL BE TIGHTLINED TO THE STORM DRAIN SYSTEM WHERE INDICATED ON THE PLANS. 17. ALL REQUIRED STORMWATER FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO INSTALLATION OF ANY PAVEMENT UNLESS OTHERWISE APPROVED BY THE ENGINEER. 18. ALL ROOF DRAINS, PERIMETER FOUNDATION DRAINS, CATCH BASINS AND OTHER EXTERNAL DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS NOTED OTHERWISE. 19. ALL FOOTING DRAINS SERVING BUILDINGS, WALLS, ROCKERIES, ETC. SHALL CONNECT OUTFALL AS SHOWN ON THE ENGINEER'S DRAWINGS. GENERAL NOTES, CONT'D 20. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR INSTALLATION OF ALL SITE IMPROVEMENTS INDICATED ON THESE DRAWINGS. 21. A SEPARATE IRRIGATION PERMIT MUST BE OBTAINED FROM THE CITY PUBLIC WORKS DEPARTMENT. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, PROVIDE TO THE CITY WATER QUALITY TECHNICIAN, A COPY OF THE BACKFLOW TEST REPORT. TEST REPORTS CAN BE FAXED TO 425-744-6057 OR EMAILED TO JEFF.KOBLYK9EDMONDSWA.GOV. BACKFLOW TESTING SHALL BE COMPLETED BY THE OWNER ANNUALLY THEREAFTER. 22. AS A MINIMUM REQUIREMENT, ALL DISTURBED AREAS ON AND OFF SITE SHALL BE RETURNED TO THE EQUIVALENT OF THEIR PRECONSTRUCTION CONDITION IN ACCORDANCE WITH APPROPRIATE REQUIREMENTS AND STANDARDS. 23. ALL DISTURBED SOIL AREAS SHALL BE COMPOST AMENDED AND SEEDED OR STABILIZED BY OTHER ACCEPTABLE METHODS FOR THE PREVENTION OF ON - SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. SEE EROSION CONTROL PLANS FOR SPECIFIC GRADING AND EROSION CONTROL REQUIREMENTS. 24. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS CLEAN AT ALL TIMES BY SWEEPING. WASHING OF THESE STREETS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL. 25. THIS PROJECT IS NOT A BALANCED EARTHWORK PROJECT. BOTH EXPORT AND IMPORT OF SOIL AND ROCK MATERIALS ARE REQUIRED. 26. SLOPE OF FINISHED GRADE SHALL BE CONSTANT BETWEEN FINISHED CONTOURS OR SPOT ELEVATIONS SHOWN. 27. FINISHED GRADE SHALL SLOPE AWAY FROM BUILDING WALLS AT MINIMUM 5% SLOPE FOR A MINIMUM DISTANCE OF 10 FEET. 28. CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL INSTALL AND MAINTAIN SHORING AND BRACING AS NECESSARY TO PROTECT WORKERS, EXISTING BUILDINGS, STREETS, WALKWAYS, UTILITIES AND OTHER EXISTING AND PROPOSED IMPROVEMENTS AND EXCAVATIONS AGAINST LOSS OF GROUND OR CAVING EMBANKMENTS. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR REMOVAL OF SHORING AND BRACING, AS REQUIRED. 29. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY AND FOLLOW CITY PROCEDURES FOR ALL WATER SERVICE INTERRUPTIONS, HYDRANT SHUTOFFS, STREET CLOSURES OR OTHER ACCESS RESTRICTIONS. CONTRACTOR SHALL NOT RELOCATE OR ELIMINATE ANY HYDRANTS WITHOUT FIRST OBTAINING WRITTEN APPROVAL FROM THE FIRE MARSHAL. 30. COORDINATE AND ARRANGE FOR ALL UTILITY CONNECTIONS, UTILITY RELOCATIONS AND/OR SERVICE INTERRUPTIONS WITH THE AFFECTED OWNERS AND APPROPRIATE UTILITY COMPANIES. CONNECTIONS TO EXISTING UTILITIES SHALL BE MADE ONLY WITH ADVANCE WRITTEN APPROVAL OF THE AUTHORITIES GOVERNING SAID UTILITIES. 31. ALL UTILITIES SHALL BE PLACED UNDERGROUND. 32. EXISTING UTILITY LINES IN SERVICE WHICH ARE DAMAGED DUE TO CONSTRUCTION WORK SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE AND INSPECTED AND ACCEPTED BY CITY OF EDMONDS AND OWNER'S REPRESENTATIVE PRIOR TO BACKFILLING. 33. NEW UTILITY LOCATIONS ARE GENERALLY SHOWN BY DIMENSION, WHERE NO DIMENSIONS ARE INDICATED, LOCATIONS MAY BE SCALED FROM DRAWINGS. FIELD ADJUSTMENTS SHALL BE APPROVED BY OWNER'S REPRESENTATIVE AND CITY. 34. FIELD STAKE ALL UTILITY STUBS AT THE PROPERTY LINE. 35. TRENCH BACKFILL OF UTILITIES LOCATED WITHIN THE CITY RIGHT-OF-WAY SHALL BE COMPACTED TO 95%. COMPACTION TEST REPORTS SHALL BE PROVIDED TO THE CITY PRIOR TO PAVING. 36. WHERE NEW PIPE CLEARS AN EXISTING OR NEW UTILITY BY 6" OR LESS, PLACE PO vE-ruvr E44E Dr A QTIC= F-9 A r AS A CUSHION BETWEEN THE UTILITIES. ETHAFOAM 200 37. SEE MECHANICAL DRAWINGS (WHERE APPLICABLE) FOR CONTINUATION OF SITE UTILITIES WITHIN THE BUILDING. 38. SEE ELECTRICAL DRAWINGS (WHERE APPLICABLE) FOR EXTERIOR ELECTRICAL WORK. 39. SEE LANDSCAPE DRAWINGS (WHERE APPLICABLE) FOR SITE IRRIGATION SYSTEM. 40. PIPE MATERIAL AND SIGNAGE SUBMITTALS SHALL BE PROVIDED TO CITY ENGINEERING DIVISION FOR APPROVAL PRIOR TO INSTALLATION. 41. CATCH BASIN DEPTHS OF 5 FEET OR MORE FROM PIPE INVERT TO TOP OF GRATE SHALL BE TYPE II. Know what's b@IOW. Call before you dig. ENGINEERING DIVISION APPROVED AS NOTED 03/28/2023