Loading...
REV1 REVIEWED BLD BLD2022-1035+Structural_Plan+9.5.2024_2.56.28_PM+4483140RB Engineers, Inc. 1312 2ND ST. KIRKLAND, WA. 98033 PH: (425) 822-3009 FAX: (425) 822-2679 CELL: (425) 351-2085 EMAIL: rbe1992Ai!mail.com -]me YlkTIYxmI11i9 ............................................... y REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT] .............................................. e JOB: IRON VISTA PROJECT #:24-9396 BY: R.B. / MJT DATE: 09/05/2024 PAGE GI OF 109 STRUCTURAL COMPUTATIONS FOR 19128 94TH AVE. W. EDMONDS WA BASIS FOR DESIGN: CODE: INTERNATIONAL BUILDING CODE (2021 EDITION) WIND: 110 MPH, EXPOSURE "C" Kzt = 1.40 SEISMIC: Ss = 1.60, S1 = 0.57 (SITE CLASS D) ROOF SNOW: 25 PSF ALLOWABLE SOIL BEARING PRESSURE: 2000 PSF PER SOILS REPORT INDEX TO COMPUTATIONS: GENERAL GI — G3 LATERAL L 1 — L21 BEAMS B 1 — B42 FOOTING F1 — F7 RET. WALL R1 — R36 RB ENGINEERS, INC. IS NOT RESPONSIBLE FOR THE SITE, SOILS, WEATHER PROOFING, TRUSSES AND/OR EXISTING CONDITIONS. REVISION Sep 06 2024 DEVELOPMENT SERVICES DEPARTMENT EXPIRES FEB 2025 RB Engineers, Inc. 12733 Holmes Point Drive NE Kirkh Phone: (425) 822-3009 Email: rbel992@gmail.com ct: ron ista y:t: ff ate:ct: Lateral I Page: G2/ LOADING CRITERIA FOR HIGH ROOF AND/OR CEILING - Main Roof Area - Canopy or Mansard Roof - Ceiling Only - Other Item Material Load PSF Roofing Composition 2.2 Sheathing or Deckin, 5 DX 1.5 Insulation 2.8 Ceiling 5 WB 2.6 Fixtures 1.0 Framing Truss 2.3 Misc. 0.6 Misc./Photovoltaic 4.0 TOTAL DEAD LOAD = 17 PSF Sprinkler (Only If A>4000 sq t 2 LIVE LOADS - Snow Load - 25 psf - non reducible - Ceiling Only - 10 psf - Increase in Fb and Fv of 15% allowed for duration of load RIB Engineers, Inc. 1312 2nd St Kirkland, WA Phone: (425) 822-3009 Email: rbel992@gmail.com Pro ect: Iron Vista y: Client: ate: 5/29/2024 Subject: Lateral Page: LOADING CRITERIA FOR FLOOR/ LOW ROOF Item Material Load PSF Floor Covering Carpet and Pad 3.0 Floor Sheathing T&G CDX 2.3 ei mg WB 2.2 Fixtures 1.0 Framing TH's 3.0 Misc I2.5 TOTAL DEAD LOAD = 14 PSF Sprinkler (Only If A>4000sq t 2 LIVE LOADS - Residential - 40 psf (reducible) - Office - 50 psf (reducible) - Assembly - 100 psf (non -reducible) - Corridors and Exits - 100 psf (reducible) - Storage - 125 psf (non -reducible) - Deck - 60 psf (non -reducible) SHEAR WALL KEY PLAN Ll/ 11— IF,GENERAL NOTES r NN EIN N,X NIT I F\�il TI xEx�ms KITCHEN E—.I11AAE1N—N1 "IN IDI- JE-- IF,I.-N'F 1"1 I-1KL-lFTNl—o 1 F —2I1F1F 1— I INNFL �IUI—­NI�NNl 'Il , _V UHN�—Al—.—IN wE TRU-- 11111E STAIRS-IRC R311F NI. D.114 FEI..NlI Exo'xExos o"aFIN 11. M- .'FT�=N '. .V— ­ �N` NN FI , LlM COFFEE BARDTL ­'=N'l—lG1-10 PREP. KT EIL1_1L111-111 STAIRWAY ILLUMINATION R203.7 ��'F%UHTII.0 " I�HA ATFT.1p I N� THIRD FLR CABINET PLANS 57 CABINET PULLS x-- NL" HIM BATHROOM NOTE 7===o.`F`plZlD �Tol`.E 01 x 1 NFT_ IN—N xrowxxroxrmx '4'IA AO �IT� Z 20-1 EMERGENCYESCAPE RCR310 21 11xin 0 NA 'L, ZE 1. —DISN IOaus@BmGUAR - RCR312 _ F , Al—T) WfIll T& 'IMAL ' A"N " T, tp ­20— B5 'L COVER a) Im 111N.El IE A ED PORC N.T 1 -1 .1 IN N-1 sr eN Tr- "W GREAT ROOM DINING AREA 10 AN GARAGE SEPARATION m II4ID uxn �T PUM' mEx ND R T�=­_­ —N A-1 JNT111rRM — EEN SB — xAVLET—�'�A'. -DLP..�'--P.Wl ELECTRICAL LEG'VA X3 END �PINTA N—L N�I�IM N=M 7 — — — Y5 IVFN Mf�� D)NN Y F- RA V` N'T F-INVINT KITCHEN TIF—E-L y 1 �IN.I'IN IN Y2 FOYER oE� 1-1 F u-j Z DEnL 2LOP LM_ IF I ng ww' OPEIG —D PREP 141 —DE— Lu UNI �E�-Wj tau —E E=11.= I. FIR Il Irl I— L TFF 01 ­N� M OF IwsI 1. NI.T'A.NDIN.H. ENTRY 10.1 p "F, 72 I—E U.1 N.N—N mr47 — IV3, HIGH EFFICIENCYLIGHTING JMFNEZ� II s 2 CAR GARAGE c Ub WALK-IN IRCN11M CD mi ImoDEN IN ..NN 1-1. ALL Fl IN-1— A-1 LIN. —SWILL FE LEIOR Y4TummsxSEES PAGES FOR ALL VEREDIDINaw 16^P IIA'L'L.N. WALK IN HOLOOOWNINFORMATION NG IF TOP ENTRYFLOOR Pic THIRD FLOOR PLAN To R 11LIMN 111111111Al— II F.IR 1. N.T 1-1 21'US I—NN HOME TO BE EQUIPPED WITH 13D FIRE X4 an ET.ioixsoumaoBuxrs APPROVED EPI ON FOR CONSTRUCTION 1. OF EDMONDS SHEAR WALL KEY PLAN L2/ HIINFAPIt I.PHA­ GENERAL NOTES 141,1 M�INN. 'V.' I N.6HI 'I L BEDROOM #2 REno P_ IN IN P EN 1E 2 0 Il NPOPIED N, TIP IRC MA wCxrtR BATH #2 01tsvum/ IM N CRAWL SPACE ACCESS EN MNUMV =.=r LI NE,1,� '11M. A C�j _E PlYDEP.­ NFININN 11 -11. 11 — I A,1I F.� IGHl, " ­E­ PON wiowAo �I5 M N' , CCCP­ NI STAIRS-IF." IN V. EE 41 .EN-- BATH #2 fIAUNDRV MASTER BATH E WALK-IN CL05ET A I(NIa.Ru)LL NI�CINNT­'FIO.CN HIA,AF.,I,lN�CMClFCA,'LUI­ N, E 1�l2l I�.F1N WSl­T=. CLOSET CABINET DTL .AlT&YBEDROOM#3 ENC-El C­.I TT.= •NNNI NPNTCF8l,­REl SECOND FLR CABINET PLANS _,_lA-..1 Al MECH AM 72 CABINETPULL5 ­EI 1 D=O�_=14,P.=EANTL A .I 1N , ARM "7`AM­F.,-_CNN,=1N11,0IFFo`PX5 ­NIIPE xER HIM STAIRWAY ILLUMINATION R203.7 = PID-PIN A, FAALLIO UFT, N_,,CNNC_ DROP CL'G t& DUCTING DETAIL A.D.T,1.1�DNNCI �C AT�FCI .I miiaAT E'rINALY" NI'WVELIN T ... . OR Ell 1 11 1 14-9 BATHROOM NOTES FjN. iv OP —IN A' LELD E NC A NITOOI&I 6&INFI ,Z I�r 1,1P IN" 2 IN I I I _EFFNI �.F L I, Sm FW7. 4?5�,, PNP. 7. PIC ,,F ,,N FW7. h Be PIC EMERGENCY ESCAPE IRC R310 CD m OF NO I � ENAOCI =l. N= "I ..... NO '"M I` TFN FILIPEPLI - PIPE �Z CIIIINNN.1 ".' =X'& sa 5TUDYAREA 4� MASTER BEDROOM ---- GUARDS IRCR312 1UPONE'N.I. �A ' """" GI RITIANII _PN SE N.RNPPN.E ='I.CP NI ,L,PER'. 'ON N "I I Bi .1ATll.P­ NI IAT�% -.1 IL . OT ILL�El - - - - - - - - - - - - - - - US tq BEDROOM #2 BEDROOM #3 N _1 PPL Y6MOINIPHADURT MASTER BATH PRIEE-N INNll.."I y9_1°wGw .I �A, mxwE IN � A =`D­ ECDI PI P, I X n113, j ­U' MOT) PAGE P)P WOP CI G LCOCIONS ARDNONI I LwEms' TI A ON Yl 0 INTERIOR FURNACE WATER HEATER GC 2111 IRINT11 NNI 11-1-PAN-1 P. WALKIN NY.L., LCT CN NOF. %ALNL!ll'l==%Z'=X `UN'T`Pl2`LV Y7 EN IN 1pll ­­ELIPRIA C OF E�== 11,1L PI.ED " ZD P, C., IN N-FEEAR-1111 xEwaCw -N, TH #2 SI N �PI lI DD 11 ,E Ul­ �A= ie pp IO-CAINCCNC1 IN-U.N..­111. m PFC­ CTF.PlP­ eM LADNER �l 1 ELECTRICAL LEGEND Y ,A,LK-,N I. -.1PEOARNIERR 1211 1 u_j I N A. ILC T DRDP 74 7__ ITFRACEE IEF, ICF_ NO 1E. I L_u ECTE I R ECTE I R -I., F- ME CICIIE IN ­D. l= TER HEACER, R­ Ul." FELIP, 7t- -P I- NI RPI `D7 I I�IEI," 1.11A.11 IAN PIC T. EP 0 T JNRO­ < 34F6 TEM PC --- 1,,PT,,= 0 U1% PAII C. N. UNVENTED NP.' EEP A CRAWL SPACE OFFNICE-1-11- A GH EFFICIENCY L GHTNG RCN1IN&WSECRF44 SECOND FLOOR PLAN ­N­ ­­�r NIMPI HOME TO BE EQUIPPED WITH 13D FIRE SPRINKLER SYSTEM APPROVED FOR 'NSPRU ON CITY OF E'DONDS F71 m. 5 SHEAR WALL KEY PLAN L3/ GENERAL NOTES SITTING RM GUEST BEDROOM NIN.ZiN."AI'l�'IXE NLAlN0TRNN­­WHIRE­­ NA LIAR1.11D I. _Y —F—GSHER A= " p ALLH-.NS _.. 9 DEER F-ING %ELF IN11- IDDIRR ED FLNI STAIRS- IRC R311 WINE CELLARINDRAN11 I —,—G E .1E AIDNEIAND1111IM-1=21, '.N All • (2) FWING NAND—<umNAN N F..I. BATH #3 II II aN.— To 3luwPLBNT. -..DFRN.I L, ZNT� Nxw DETAIL FIRST FLR CABINET PLANS D.—N 11F Y, I 1 48 CABINET PULLS ICAR Y, I LI �I.WIMNDEN—N-1-0 I_ WET BAR DTL D.EN.NlND= Eens- ­,IID� FFIFN.4� oi� 2DA""""To LONINUDUll—Ul ATAIII-NI E "'DD STAIRWAY ILLUMINATION I T'FA UFFl — =D, N1111 1— 1 11 X7BATHROOM NOTE 111— 01 ­LNE LEN ­­ DIT_ AID I—. Cn EMERGENCYESCAPE IRCR310 3 'IR I N " 1. RAD N, 0 —.IINNI —..-1 ILDIF ELECTRICAL LEGEND E, G Jrf 1 EN I=MIFR�UEl.IlNlN­ N DRY, ID ALL.LENGTHRUILRINDEEN .1u WIE A 41- _�rl T ­—T Y12 "e_"';ATH#3 w�NsoxacPITE -NI-RDIRLDRINIII ' " L NVAIEDARIIRIII��'� LffILEID1 1 1 �, ? N, NE.1,1.11 IAN cm6) N T� m 111MIT11ATI GAMEROOM Y15 GUEST BEDROOM UNT01U11I 'L yl i SITTING RM wxuro EAT (".A.. 'NIIN"P'll NAAET 'E EZ) low �..Tomsl_ =.I��NRNDIA.LLERIN.NII A, IN 3K RK —IE-1—N.11—N ILI r 'E Y13� —Y16 L HIGH EFFICIENCYLGHTUNG YE, IFE, IRCN1104&WSECR� R 11 1_ �7­7'1 wnrsNus BUIURINS IVLINEN. 0PAGE V I STORAGE IF USW4 %UWI'­=�E .R m IND I.Dl AEA Lu ------------- fF2 "N' _J1 S,CE I EATL �'A Lu i L X8 iI SEES PAGES FOR ALL L------------------ FIRST FLOOR PLAN ADALEM 11 HOME TO BE EQUIPPED WITH 13D FIRE SPRINKLER SYSTEM APPROVED FOR CONSTRUCTION RU CITY OF EDMONDS F71 Diagrams Case B Notation L4/ a 10% of least horizontal dimension or 0.4 h, whichever is smaller, but not less than either 4% of least horizontal dimension or 3 ft (0.9 m). EXCEPTION: For buildings with 0 = 0 to 7° and a least horizontal dimension greater than 300 ft (90 m), dimension a shall be limited to a maximum of 0.8 h. h Mean roof height, in ft (m), except that eave height shall be used for roof angles < 10°. 0 Angle of plane of roof from horizontal, in degrees. Notes 1. Pressures shown are applied to the horizontal and vertical projections, for Exposure B, at h = 30 ft (h = 9.1 m). Adjust to other exposures and heights with adjustment factor X. 2. The load patterns shown shall be applied to each comer of the building in turn as the reference corner (See Fig. 28.3-1). 3. For Case B, use 0 = 00. 4. Load cases 1 and 2 must be checked for 25' < 0 < 45°. Load case 2 at 25' is provided only for interpolation between 25' and 30°. 5. Plus and minus signs signify pressures acting toward and away from the projected surfaces, respectively. 6. For roof slopes other than those shown, linear interpolation is permitted. 7. The total horizontal load shall not be less than that determined by assuming p, = 0 in Zones B and D. 8. Where Zone E or G falls on a roof overhang on the windward side of the building, use EoH and GoH for the pressure on the horizontal projection of the overhang. Overhangs on the leeward and side edges shall have the basic zone pressure applied. 9. Unit conversions for tables: Adjustment Factor for Building Height and Exposure, X Mean roof height (it) a Exposure c D 15 1.00 1.21 1.47 20 1.00 1.29 1.55 25 1.00 1.35 1.61 30 1.00 1.40 1.66 35 1.05 1.45 1.70 40 1.09 1.49 1.74 45 1.12 1.53 1.78 50 1.16 1.56 1.81 55 1.19 1.59 1.84 60 1.22 1.62 1.87 Note: Unit conversions for tables: 1.0 ft = 0.3048 m; 1.0 Ib/ftz = 0.0479 kN/m2; 1 mph =1.6 km/h FIGURE 28.5-1 Main Wind Force Resisting System, Part 2 [h < 60 ft (h < 18.3 m)]: Design Wind Pressures for Enclosed Buildings -Walls and Roofs I - continues 316 STANDARD ASCE/SEI 7-16 Simplified Design Wind Pressure, Ps3p (psi) for Exposure B at h = 30 It (h = 9.1 m) Basic Wind Speed (mph) Roo( Angle (degrees) Load Case Zones Horizontal Pressures Vertical Pressures Overhangs A B C D E F G H EoH GoH 105 0 to 5° 1 17.5 -9.1 11.6 -5.4 -21.0 -11.9 -14.6 -9.2 -29.4 -23.0 10, 1 19.7 --8.2 13.1 -4.8 -21.0 -12.8 -14.6 -9.9 -29.4 -23.0 15° 1 22.0 -7.3 14.6 -4.1 -21.0 -13.7 -14.6 -10.5 -29.4 -23.0 20° 1 24.2 -6.4 16.1 -3.5 -21.0 -14.6 -14.6 -11.1 -29.4 -23.0 25° 1 2 21.9 - 3.5 - 15.9 - 3.6 - -9.7 -3.7 -13.3 -7.2 -7.1 -1.0 -10.7 -4.6 -18.2 - -15.5 - 30 to 45 1 2 19.7 19.7 13.4 13.4 15.6 15.6 10.8 10.8 1.5 7.6 -11.9 -5.9 0.5 6.6 -10.3 -4.2 -6.9 -6.9 -7.9 -7.9 110 1 19.2 -1 1 .7 -23.1 -13.1 -16.0 -10.1 -32.3 -25.3 10° 1 21.6 -9.0 14.4 -5.2 -23.1 -14.1 -16.0 -10.8 1 -32.3 -25.3 15° 1 24.1 -8.0 16.0 -4.6 -23.1 -15.1 -16.0 -11.5 -32.3 -25.3 20° 1 26.6 -7.0 17.7 -3.9 -23.1 -16.0 -16.0 -12.2 -32.3 -25.3 25° 1 2 24.1 - 3.9 - 17.4 - 4.0 - -10.7 -4.1 -14.6 -7.9 -7.7 -1.1 -11.7 -5.1 -19.9 - -17.0 - 30 to 45 1 2 21.6 21.6 14.8 14.8 17.2 17.2 11.8 11.8 1.7 8.3 -13.1 -6.5 0.6 7.2 -11.3 -4.6 -7.6 -7.6 -8.7 -8.7 115 0 to 5° 1 21.0 -10.9 13.9 -6.5 -25.2 -14.3 -17.5 -11.1 -35.3 -27.6 10° 1 23.7 -9.8 15.7 -5.7 -25.2 -15.4 -17.5 -11.8 -35.3 -27.6 15° 1 26.3 -8.7 17.5 -5.0 -25.2 -16.5 -17.5 -12.6 -35.3 -27.6 20° 1 29.0 -7.7 19.4 -4.2 -25.2 -17.5 -17.5 -13.3 -35.3 -27.6 25° 1 2 26.3 - 4.2 - 19.1 - 4.3 - -11.7 -4.4 -15.9 -8.7 -8.5 -1.2 -12.8 -5.5 -21.8 - -18.5 - 30 to 45 1 2 23.6 23.6 16.1 16.1 18.8 18.8 12.9 12.9 1.8 9.1 -14.3 -7.1 0.6 7.9 -12.3 -5.0 -8.3 -8.3 -9.5 -9.5 120 0 to 5° 1 22.8 -11.9 15.1 -7.0 -27.4 -15.6 -19.1 -12.1 -38.4 -30.1 10° 1 25.8 -10.7 17.1 -6.2 -27.4 -16.8 -19.1 -12.9 -38.4 -30.1 15° 1 28.7 -9.5 19.1 -5.4 -27.4 -17.9 -19.1 -13.7 -38.4 -30.1 20° 1 31.6 -8.3 21.1 -4.6 -27.4 -19.1 -19.1 -14.5 -38.4 -30.1 25° 1 2 28.6 - 4.6 - 20.7 - 4.7 - -12.7 -4.8 -17.3 -9.4 -9.2 -1.3 -13.9 -6.0 -23.7 - -20.2 - 30 to 45 1 2 25.7 25.7 17.6 17.6 20.4 20.4 14.0 14.0 2.0 9.9 -15.6 -7.7 0.7 8.6 -13.4 -5.5 -9.0 -9.0 -10.3 -10.3 125 0 to 5° 1 24.8 -12.9 16.4 -7.6 -29.8 -16.9 -20.7 -13.1 -41.7 -32.6 10° 1 27.9 -11.6 18.6 -6.7 -29.8 -18.2 -20.7 -14.0 -41.7 -32.6 15° 1 31.1 -10.3 20.7 -5.9 -29.8 -19.5 -20.7 -14.8 -41.7 -32.6 20° 1 34.3 -9.1 22.9 -5.0 -29.8 -20.7 -20.7 -15.7 -41.7 -32.6 25° 1 2 31.1 - 5.0 - 22.5 - 5.1 - -13.8 -5.2 -18.8 -10.2 -10.0 -1.4 -15.1 -6.6 -25.7 - -21.9 - L-1 30 to 45 1 2 27.9 27.9 19.1 19.1 22.2 22.2 15.2 15.2 2.1 10.7 -16.9 -8.3 0.7 9.3 -14.5 -6.0 -9.8 -9.8 -11.2 -11.2 L5/ FIGURE 28.5-1 (Continued). Main Wind Force Resisting System, Part 2 [h < 60 ft (h < 18.3 m)]: Design Wind Pressures for Enclosed Buildings -Walls and Roofs continues 318 STANDARD ASCE/SEI 7-16 RB Engineers, Inc. 1312 2nd St Kirkland, WA Phone: (425) 822-3009 E '1 b @ E Fw Roof = 19.2x(8/2x(5.5+5.75)+8x7.25) + 12.7x(4.5/2x(5.75+6)+20x7.25) 4.15 4.15 x 1.4 Kzt x 1.4 x 0.6 = 4.88 kip Y. Fw Upper = 19.2x(8/2x(7.75+11)+8x 11) + 12.7x(24.5x 11) _ 6.56 6.56x 1.4Kztx 1.4x0.6= 7.71 kip Y. Fw Main = 19.2x(8x9.25) + 12.7x(l/2x(24.5x9.25)) _ 2.86 2.86x 1.4Kztx 1.4x0.6= 3.36 kip Roof Min =[(103+171)xl6+(0)x8)]xl.4xl.4x0.6 = kip Upper Min =[(163+270)xl6+(0)x8)]xl.4xl.4x0.6 = 8.15 kip Main Min =[(74+113)xl6+(0)x8)]xl.4xl.4x0.6 = 3.52 kip Y - Y Direction Y. Fw Roof = 19.2x(13.5x6.25+13.5x6.25) + 12.7x(40.75x6.25) _ 6.48 6.48 x 1.4 Kzt x 1.4 x 0.6 = E Fw Upper = 19.2x(13.5x11+13.5x11) + 12.7x(40.75x11) _ 11.39 11.39x 1.4Kztx 1.4x0.6= E Fw Main = 19.2x(13.5x9.25+13.5x9.25) + 12.7x(40.75x9.25) _ 7.62 kip 13.40 kip 9.59 9.59x 1.4Kztx 1.4x0.6= 11.28 kip Roof Min =[(169+255)x16+(0)x8)]x1.4x1.4x0.6 = Upper Min =[(297+448)x16+(0)x8)]x1.4x1.4x0.6 = 7.98 kip 14.02 kip Main Min =[(250+377)x16+(0)x8)]x1.4x1.4x0.6 = 1 1.80 kip RB Engineers, Inc. 1312 2nd St Kirkland, WA Phone: (425) 822-3009 Email: rbel992@gmail.com Site Class "D" (Table 1 L4.2) Project: Iron Vista By: RB/MJT Client: Date: 5 29 2024 Subject: Lateral Page: L8/ QUAKE FORCES (ASCE 7-16) Ss = Critical Values per Latest SEAOC website; 1.6 S 1 = Critical Values per Latest SEAOC website; 0.57 Fa =per Table 11.4-1 1 Fv = per Table 11.4-2 1.8 Sms = Fa * Ss = 1.0 (1.6) 1.6 (11.4-1) Sml = Fv * S1 = 1.8 (0.57) 1.03 (11.4-2) Sds = 2/3 * Sms = 2/3 (1.60) 1.07 (11.4-3), Seismic Design Category "D", Table 11.6-1 Shc = 2/3 * Sml = 2/3 (1.03) 0.68 (11.4-4); Seismic Design Category D, Table 11.6-2 SEISMIC RESPONSE COEFFICIENT: Use Section (12.8.1.1) ASCE 7-16 Except as Noted To = 0.2 (Shc/Sds)=0.2(0.68/1.07) 0.13 Section 11.4.6 Ts = Shc /Sds=(0.68/1.07) 0.64 Section 11.4.6 Ct 0.02 Hn (Bldg. height-ft)) 35.00 Tstruc = Ct * (Hn)^3/4 = 0.02(35^.75) 0.29 Table 12.8-2 Where To < Tstruc < Ts; Sa = Sds 1.07 Section 11.4.6, item 2 R 6.5 ASCE 7-16 Table 12.2-1, item 15 Ie 1 Section 11.5.1, Table 1.5-1 and 1.5-2) Cs = Sds /(R/I) = 1.07 / (6.5/1) = 0.16 (12.8-2) Cs 0.16 RB Engineers, Inc. 1312 2nd St Kirkland, WA Phone: (425) 822-3009 Email: rbe1992@gmail.com Project: Iron Vista By: RB/MJT lent: ate: u ect: Lateral Page: L9/ LATERAL QUAKE FORCES Cs: 0.16 p: 1.0 Roof Area: 2994 feet ` Roof Dead Load: 17 psf Upper Area: 2495 feet ` Floor Dead Load: 14 psf Main Area: 1698 feet ` Wall Dead Load: 10 psf ASCE 7-16 Using Allowable Stress Design, 2.4.5 Basic Combination option 10: 0.6 D + 0.7 Eh-0.7E ASCE 7-16 Table 12.2-1: Overstrength factor, = 2.5 DEAD LOAD OF STRUCTURE Roof Weight = 2994 x (17+10/2) _ = 65.87 kip Upper Weight = 2495 x (14+10) _ = 59.88 kip Main Weight = 1698 x (14+10) _ = 40.75 kip 166.50 kip Vbase = Cs x E Weight = 0.16 x 166.50 = 26.64 kip Vasd = Vbase x 0.7 x p = 18.65 kip LATERAL FORCES WEIGHT HEIGHT WEIGHT x HEIGHT Roof: 65.87 kip 30.75 Feet 2025.44 Upper: 5 9.8 8 kip 18.5 Feet 1107.78 Main: 40.75 kip 9 Feet 366.77 3499.99 Fq Roof. 24.24 x (2025.44/3499.99) _ = 10.79 kip Fq Upper: 24.24 x (1107.78/3499.99) _ = 5.90 kip Fq Main: 24.24 x (366.77/3499.99) _ = 1.95 kip Therefore wind Roverns at Main in Y-Y direction, quake governs all else. ro ect: Iron Vista y: Client: ate: 5/29/2024 u ect: Lateral age: RIB Engineers, Inc. 1312 2nd St Kirkland, WA Phone: (425) 822-3009 Email: rbel992@gmail.com WIND FORCES ON SHEAR WALLS Shearwalls in X — X Direction Fw X — X @ Roof: 5.16 kips 5.16 k / 40.5 ft = 127 #/Ft V @ X 1 = (5.16/40.5)(12/2) = 0.76 = 102 # 7.5' Ft V @ X 2 = (5.16/40.5)(12/2+12/2) = 1.53 < 3.35 kip LRP capacity LRP = 2x24"x8' = 2xl6751b = 3.35 kip LRP capacity V @ X 3 = (5.16/40.5)(12/2+12/2) = 1.53 = 100 # 5.5'++9..75 Ft V @ X 4 = (5.16/40.5)(12/2+4.5) = 1.34 < 3.35 kip LRP capacity W- x 4"x8' = 2xl6751b = 3.35 kip LRP capacity Fw X — X @ Upper: 8.15 kips 8.15 k / 28 ft = 291 #/Ft V @ X 5 = (8.15/28)(24/2) 5.02 = 156 # SW-4 + 0.76 4'+3.75'+ITS'+8'+6.5' Ft + 1.53x(12/24) _ (1.25-0.125x(9/3.75))x350 #/Ft = 333 #/Ft capacity per sect. 4.3.3 ANSI/AF+PA SDPWS 2021 V @ X 6 = (8.15/28)(24/2+4) 6.95 = 121 # �+ 1.53x(12/24) 13.25�5=+34' Ft +1.53= Fw X — X @ Main: 3.52 kips V @ X 7 = (3.52/24)(20.5/2) W®- + 5.02 = V @ X 8 = (3.52/24)(20.5/2+3.5) W®- + 6.95 = 2.87 k / 24 ft = 147 #/Ft 6.52 = 216 # 13.75+T5+-5+6.5' Ft 8.96 = 280 # 32' Ft y: RIB Engineers, Inc. ro ect: Iron Vista Shearwalls in Y — Y Direction Fw Y — Y @ Roof: 7.98 kips 7.98 k / 67.75 ft = 118 V @ Y 1 = (7.98/67.5)(23/2) = 1.36 = 57 #/Ft Ft V @ Y 2 = (7.98/67.5)(23/2+5+7/2) = 2.36 — 112 # 11.5� SW- Ft V @ Y 3 = (7.98/67.5)(7/2+10/2) = 1.00 — 126 # 8' Ft V @ Y 4 = (7.98/67.5)(17/2+22.5/2) = 1.91 — 201 # 9' Ft V @ Y 5 = (7.98/67.5)(22.5/2) = 1.33 — 44 # 16.25'+14' Ft Fw Y — Y @ Upper: 14.02 kips 14.02 k / 67.75 ft = 207 #/Ft V @ Y 6 = (14.02/67.75)(13/2) 2.70 = 150 # �+ 1.36 = 18' Ft V @ Y 7 = (14.02/67.75)(13/2+10/2) = 2.38 = 433 # �' Ft V @ Y 8 = (14.02/67.75)(10/2+29/2) 6.36 = 318 # �+ 2.36 = 12 + + Ft V @ Y 9 = (14.02/67.75)(29/2+15.5/2) = 4.58 = 339 # 5 + . 5' Ft (1.25-0.125x(9/4.25))x350 #/Ft = 345 #/Ft capacity per sect. 4.3.3 ANSI/AF+PA SDPWS 2021 V @ Y 10 (14.02/67.75)(15.5/2) 2.93 — 138 # �+ 1.33 = .5'+6.75' Ft L12/ Fw Y — Y @ Main: 11.80 kips 11.80 k / 67.75 ft = 174 #/Ft V @ Y 11 (11.80/67.75)(13/2) 3.84 = 160 # �+ 2.70 = 24' Ft V @ Y 12 (11.80/67.75)(13/2+10/2) 4.38 = 365 # �+ 2.38 = 12' Ft V @ Y 13 (11.80/67.75)(10/2+8/2) 7.93 = 634 # �+ 6.36 = 11' Ft V @ Y 14 (11.80/67.75)(8/2+22.5/2) = 2.66 = 443 # 6' Ft V @ Y 15 (11.80/67.75)(22.5/2+14.25/2) 7.78 — 622 # �+ 4.58 = 12.5' Ft V @ Y 16 (11.80/67.75)(14.25/2) 4.17 — 327 # �+ 2.93 = 12.75' Ft ro ect: on Vista y: lent: ate: 5/29/2024 Subject: Lateral age: RIB Engineers, Inc. 1312 2nd St Kirkland, WA Phone: (425) 822-3009 Email: rbe1992@gmail.com QUAKE FORCES ON SHEAR WALLS Shearwalls in X — X Direction Fw X — X @ Roof. 10.79 kips 10.79 k / 40.5 ft = 266 #/Ft V @ X 1 = (10.79/40.5)(12/2) = 1.60 = 213 # 7•5' Ft V @ X 2 = (10.79/40.5)(12/2+12/2) = 3.20 < 3.35 kip LRP capacity LRP = 2x24"x8' = 2x16751b = 3.35 kip LRP capacity V @ X 3 = (10.79/40.5)(12/2+12/2) = 3.20 = 210 # W®- 5.5'++9..75 Ft V @ X 4 = (10.79/40.5)(12/2+4.5) = 2.80 < 3.35 kip LRP capacity W- x 4"x8' = 2x16751b = 3.35 kip LRP capacity Fw X — X @ Upper: 5.90 kips 5.90 k / 28 ft = 211 #/Ft V @ X 5 = (5.90/28)(24/2) 5.73 = 178 # SW-4 + 1.60 4'+3.75'+ITS'+8'+6.5' Ft + 3.20x(12/24) _ (1.25-0.125x(9/3.75))x350 #/Ft = 333 #/Ft capacity per sect. 4.3.3 ANSI/AF+PA SDPWS 2021 V @ X 6 = (5.90/28)(24/2+4) 8.17 = 142 # �+ 3.20x(12/24) 13.25 +Tl 7+34' Ft + 3.20 = Fw X — X @ Main: 1.95 kips V @ X 7 = (1.95/24)(20.5/2) �+ 5.73 = V @ X 8 = (1.95/24)(20.5/2+3.5) W®- + 8.17 = 1.95 k / 24 ft = 81 #/Ft 6.56 = 217 # 13.75 +T5 +6.5' Ft 9.29 = 290 # 32' Ft RIB Engineers, Inc. ro ect: on Vista Shearwalls in Y — Y Direction Fw Y — Y @ Roof. 10.79 kips 10.79 k / 67.5 ft = 159 V @ Y 1 = (10.79/67.5)(23/2) = 1.84 = 77 #/Ft Ft V @ Y 2 = (10.79/67.5)(23/2+5+7/2) = 3.19 = 152 # SW- .5 +�8.5 Ft V @ Y 3 = (10.79/67.5)(7/2+10/2) = 1.36 = 170 # t Ft V @ Y 4 = (10.79/67.5)(17/2+22.5/2) = 2.59 = 272 # W®- 9' Ft V @ Y 5 = (10.79/67.5)(22.5/2) = 1.80 = 59 # 16.25'+14' Ft Fw Y — Y @ Upper: 5.90 kips 5.90 k / 67.75 ft = 87 #/Ft V @ Y 6 = (5.90/67.75)(13/2) 2.40 — 134 # �+ 1.84 = 18' Ft V @ Y 7 = (5.90/67.75)(13/2+10/2) = 1.00 — 182 # 5•5' Ft V @ Y 8 = (5.90/67.75)(10/2+29/2) 4.87 = 244 # �+ 3.19 = + +7 Ft V @ Y 9 = (5.90/67.75)(29/2+15.5/2) = 1.93 = 143 # W®- t .255'++.25' Ft (1.25-0.125x(9/4.25))x350 #/Ft = 345 #/Ft capacity per sect. 4.3.3 ANSI/AF+PA SDPWS 2021 V @ Y 10 (5.90/67.75)(15.5/2) 2.47 = 116 # �+ 2.34 = 4.5'+6.75' Ft L 15/ Fw Y — Y @ Main: 1.95 kips 2.54 k / 67.75 ft = 29 #/Ft V @ Y 11 (1.95/67.75)(13/2) 2.59 = 108 # �+ 2.40 = 24' Ft V @ Y 12 (1.95/67.75)(13/2+10/2) 1.33 = 111 # �+ 1.00 = 12' Ft V @ Y 13 (1.95/67.75)(10/2+8/2) 5.13 = 446 # W-3 + 4.87 = III Ft V @ Y 14 (1.95/67.75)(8/2+22.5/2) = 0.44 = 73 # 6' Ft V @ Y 15 (1.95/67.75)(22.5/2+14.25/2) 2.46 = 197 # �+ 1.93 = 12.5' Ft V @ Y 16 (1.95/67.75)(14.25/2) 2.68 = 210 # �+ 2.47 = 12.75' Ft RB Enl4ineers, Inc. rojec : iron Vista BY: ien : Date: Subject: a era age: L16 CHECK OVERTURNING FOR: X 3 (Quake) L = 5.5 ft TLRF = 5 ft (conservative) P = 210 1 lb/ft P x L 5.5x210 1.16 kip MoT= 1.16x 10.3 11.90 kip -ft S ds= 1.07 From Cs Calculations Ev = .7(0.2*S_ds)= 0.15 MR = [(0.16+0.20)x0.5x5.5+0.14x5.5] _ 1.75 kip - ft H= F=MoT-MR/L=®5 kip Positive # : Hold down required Negative # : No Hold down Required Therefore use (1)CS16 hold downs at each end Padj = D .7Ev D D -.7Ev 0.3 1 0.04 0.14 L = 5.5' Ev q RB Enl4ineers, Inc. rojec : iron Vista BY: ien : Date: Subject: a era age: L17/ CHECK OVERTURNING FOR: X 5 (Quake) L = .75 ft TLRF = 5 ft (conservative) P = 178 1 lb/ft P x L 3.75X178 0.67 kip Padj = MoT = 0.67 x 9 6.01 kip - ft S ds= 1.07 From Cs Calculations Ev = .7(0.2*S_ds)= 0.15 MR =[(0.11+0.12)x0.5x3.75+0.27x3.75] _ 1.45 kip - ft H= F=MoT-MR/L= j 1-, -2 27 kip Positive # : Hold down required Negative # : No Hold down Required Therefore use (I)CS 16 or STHD14 hold downs at each end D .7Ev D D -.7Ev 0.6 1 0.09 0.27 L=3.75' ♦1 Ev El RB Enl4ineers, Inc. rojec : iron Vista BY: ien : Date: Subject: a era age: L18 CHECK OVERTURNING FOR: X 7 (Quake) L = 5 ft TLRF = 5 ft (conservative) P = 217 1 lb/ft PxL= 5x 17 1.09 kip MoT = 1.09 x 9 9.77 kip - ft S ds= 1.07 From Cs Calculations Ev = .7(0.2*S_ds)= 0.15 MR = [(0.15+0.16)x0.5x5+0.4lx5] _ 2.80 kip - ft H= F=MoT-MR/L= kip Positive # : Hold down required Negative # : No Hold down Required Therefore use STHD14 hold downs at each end Padj = D .7Ev D D -.7Ev 0.9 0.13 0.41 L=5' Ev q RB Enl4ineers, Inc. rojec : iron Vista BY: ien : Date: Subject: a era age: L19/ CHECK OVERTURNING FOR: Y 4 (Quake) L ft TLRF = 5 ft (conservative) P = 272 lb/ft P x L 9x272 2.45 kip Padj = MoT = 2.45 x 10.3 25.21 kip - ft S ds= 1.07 From Cs Calculations Ev = .7(0.2*S_ds)= 0.15 MR = [(0.26+0.33)x0.5x9+0.14x9] _ 3.91 kip - ft H F=MoT-MR/L= 0kip Positive # : Hold down required Negative # : No Hold down Required Therefore use QCS 16 hold downs at each end D .7Ev D D -.7Ev L=9' ♦I Ev El RB Enl4ineers, Inc. rojec : iron Vista BY: ien : Date: Subject: a era age: L20/ CHECK OVERTURNING FOR: Y 5 (Quake) L = 7 ft TLRF = 5 ft (conservative) P = 244 lb/ft P x L 7x244 1.71 kip Padj = MoT= 1.71 x9 15.37 kip -ft S ds= 1.07 From Cs Calculations Ev = .7(0.2*S_ds)= 0.15 MR = [(0.21+0.23)x0.5x7+0.27x7] _ 3.41 kip - ft H= F=MoT-MR/L= 0kip Positive # : Hold down required Negative # : No Hold down Required Therefore use (I)CS 16 or STHD14 hold downs at each end D .7Ev D D -.7Ev 0.6 1 0.09 0.27 L=7' ♦I Ev El RB Enl4ineers, Inc. rojec : iron Vista BY: ien : Date: Subject: a era age: L21/21 CHECK OVERTURNING FOR: Y 13 (Wind) L ft TLRF = 5 ft (conservative) P = 634 lb/ft P x L 10.75 x 982 6.97 kip Padj = MoT = 10.56 x 9 62.77 kip - ft S ds= 1.07 From Cs Calculations Ev = .7(0.2*S_ds)= 0.15 MR =[(0.31+0.35)x0.5x10.75+0.41x10.75] _ 8.20 kip - ft H= F=MoT-MR/L= 4.96 kip Positive # : Hold down required Negative # : No Hold down Required Therefore use HTT5 hold downs at each end D .7Ev D D -.7Ev L = 10.75' I Ev El B 1 /42 BEAM KEY PLAN GENERAL NOTESIN � r J 33 _c ROOF TRUSSES - IRC 1801.10 u�sNvl i. J UNVENTED ATTIC SPACE-IRCRRO6 FSSXYL IDN BM #7 START TRUSS L.O. R,.mPoIxT 24"O.C. THIS CORNER BM #5 _ N 3m BM #4 > 3 24 1. /ANG FT —17L 11 II II II = II II II II = II II II II II II II II II II II II II II II II II II II II II II II II II BM #6 1-1-LL IL � Ll_ `-LIJL s Ll oxil 1-1w 1 BM #1 R ,. � xwxnx Eox , ,I—LIIGI o — 'R,.,. wx x Eox BM #3 __ _ __==1'I__ _— II , __—.REw_ ilk _g NG , NEIENoy E wl l Frtxs@ze• o a s —war aI"Ai u�a OH, .c aurtuu 141,1 x 1 o wDE SFHANG ON BW a � I � I� II��II III _ _-_�IfIEWSTIIE-_ Lu Ur �,:.79Q I Lu .Z II�� II II II II II II II II =14 A E ;III -� II ° II , II II II II II III II II I II II II II e II II II II 'll I - ______ __ III II_ II II�=11 IIII II II II II II II II II III II II II II II II II II ^I = BM #2 14 _ �_ _ — SEE S PAGES FOR ALL rza uv a Exx. — — I � II II II II II II II II �I STRUCTURE, SHEARWALL& � HOLDDOWN INFORMATION JLL JL 1-j ROOF FRAMING PLAN LOWER ROOFS rz��naoiwu�x � Ss 34 APPROVED FOR DONGTRUCIION CDY OF EOMONOS F71 8.2 B2/42 BEAM KEY PLAN GENERAL NOTESIN � r J 33 _c J START TRUSS L.O. 24"O.C. THIS CORNER N 3m RV IN i3 sus BM #8 s— LL— § w J N ExEasr�aEwr3e W C� d § Q § O J SEE S PAGES FOR ALL STRUCTURE, SHEARWALL& HOLDDOWN INFORMATION THIRD FLOOR FRAMING PLAN APPROVED FOR MICRON C110N Cm OF EDMON05 F71 Ex�w�EoxianE� _� � Y II II II II II II II II Ila II II II � G 'i�'� II II III � II II I II � III, II II II li li li I EdE I�_ll 11 11 11 11 l „ II II II �� II II II II h=11 g�ll �� II „II���II II II II II II II II II I'I II II 1 II II II II II II II hl " Ilos_II II II II _JI—II— II II II II II III II I u G �3 Aa ,I „ „ I, „ I II II II II � III II Ilcll „ II II II II II III �4m� I; + U -II Illls __�- „�+,��,I>CIII ll—truer-IT—D II I II II II II II II II II I II I II II II II II II II II II II II II II II II i II II II II II I�„JI II II II II II II II II II NII—III II�� � ���_ - H� III II �II Illµ) � lTl I�� �_�,—� N II II II II II II � , a III 3/ .�� III II II � ��h4ro ��x:� NMo � _ II � II II " II II II SX�tltu(talW:°fu[° II ,,,m II� II I II II II� II II II II II II II I II II II II II II II I VnrtsiolMEPIORHu°xuNFSElsiaaun s1EMVlnLL " ixauiourennneovs uvwcAwss °aluFwnv _______________ `- '� aooFolulxixax 1 s_ B3/42 BEAM KEY PLAN BM #12 START TRUSS L.O. 24"O.C. THIS CORNER I a I I L--------------------------- I I I � L GENERAL NOTES J 3 E _ "E"��.wEo�o�oEo�wurM�:anow��wau da BM #10 SEES PAGES FOR ALL STRUCTURE, SHEARWALL BI HOLDDOWNINFORMATION SECOND FLOOR FRAMING PLAN -9. - APPROVED FOR DMOND UC11oN Cm OF EC NMR W J a to W d Q J Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: B4/42 Printed: 18 JUN 2024, 2:15PM Steel Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM#1 CODE REFERENCES Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method Allowable Strength Design Fy : Steel Yield : 50.0 ksi Beam Bracing : Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending 1610) L(0.2875) D(0.3220) I L(0.5750) W 12x22 Span = 27.50 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0140, L = 0.0250 ksf, Extent = 0.0 - > 23.50 ft, Tributary Width = 11.50 ft Point Load : D = 0.3220, L = 0.5750 k @ 23.50 ft, (PL from Rafters) DESIGN SUMMARY Maximum Bending Stress Ratio = 0.580 : 1 Maximum Shear Stress Ratio = 0.096 : 1 Section used for this span W12x22 Section used for this span W12x22 Ma: Applied 42.397 k-ft Va : Applied 6.167 k Mn / Omega: Allowable 73.104 k-ft Vn/Omega : Allowable 63.960 k Load Combination +D+L Load Combination +D+L Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.821 in Ratio = 401 > 360 Span: 1 : L Only Max Upward Transient Deflection 0 in Ratio = 0 <360 n/a Max Downward Total Deflection 1.281 in Ratio = 258 > 240. Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio = 0 <240.0 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stresses mammary of Moment Va ues Summary of Shear Values Seqment Lenqth Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega D Only Dsgn. L = 27.50 ft 1 0.208 0.035 15.22 +D+L Dsgn. L = 27.50 ft 1 0.580 0.096 42.40 +D+0.750L Dsgn. L = 27.50 ft 1 0.487 0.081 35.60 +0.60D Dsgn. L = 27.50 ft 1 0.125 0.021 9.13 Overall Maximum Deflections 15.22 122.08 73.10 1.001.00 42.40 122.08 73.10 1.001.00 35.60 122.08 73.10 1.001.00 9.13 122.08 73.10 1.001.00 Load Combination Span Max. "" Defl Location in Span Load Combination +D+L 1 1.2806 13.750 Vertical Reactions Support notation : Far left is #' Load Combination Support 1 Support 2 Max Upward from all Load Conditions 6.167 5.270 Max Upward from Load Combinations 6.167 5.270 Max Upward from Load Cases 3.953 3.378 D Only 2.214 1.892 2.21 95.94 63.96 6.17 95.94 63.96 5.18 95.94 63.96 1.33 95.94 63.96 Max. "+" Defl Location in Span 0.0000 0.000 Values in KIPS Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: B5/42 Printed. 18 JUN 2024, 2:15PM Steel Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM#1 Vertical Reactions Support notation : Far left is # Values in KIPS Load Combination Support 1 Support 2 +D+L 6.167 5.270 +D+0.750L 5.179 4.425 +0.60D 1.328 1.135 L Only 3.953 3.378 Steel Section Properties : W12x22 Depth = 12.300 in I xx Web Thick = 0.260 in S xx Flange Width = 4.030 in R xx = Flange Thick = 0.425 in Zx = Area = 6.480 inA2 1 yy = Weight = 22.000 plf S yy = Kdesign = 0.725 in R yy = K1 = 0.625 in Zy = rts = 1.040 in Ycg = 6.150 in 156.00 in^4 J = 0.293 in^4 25.40 inA3 Cw = 164.00 inA6 4.910 in 29.300 inA3 4.660 in^4 2.310 inA3 Wno = 12.000 inA2 0.848 in Sw = 5.120 inA4 3.660 inA3 Qf = 4.760 in^3 Qw = 14.400 inA3 t61 SA2 819 WIN 119 1642 19111 Ul3 N.61 Nk Xance fl 1 DOoll I+D+61447S611466D Kirkland, WA 98034 Steel Beam LIC# : KW-06015928, Build:20.23.08.30 DESCRIPTION: 13M#1 F Y v r Project Title: Engineer: Project ID: Project Descr: RB Engineers, Inc. B6/42 Printed: 18 JUN 2024, 2:15PM Project File: Iron Vista.ec6 (c) ENERCALC INC 1983-2023 iFl 542 B11 1092 1361 16A2 1911 2692 2461 D�1ice(R) 1 DOoll I+D+61+D+D,1911+6,6DD 59 S21 134 11141 BIN 69S 1i162 21d9 t396 wance(R) 1 Holl I+D+6I047S61 I+6661) 110lf Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: B7/42 Printed: 21 AUG 2024, 11:11AM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM#2 CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Fb + 2,900.0 psi E : Modulus of Elasticity Load Combination IBC 2021 Fb - 2,900.0 psi Ebend- xx 2,000.Oksi Fc - Prll 2,900.0 psi Eminbend - xx 1,016.54ksi Wood Species iLevel Truss Joist Fc - Perp 750.0 psi Wood Grade Parallam PSL 2.0E Fv 290.0 psi Ft 2,025.0 psi Density 45.070 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(2.6) L(3.8) D(0.102� L(0.15) 7x14 Span = 22.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0170, L = 0.0250 ksf, Tributary Width = 6.0 ft Point Load : D = 2.60, L = 3.80 k @ 11.0 ft DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.929. 1 Maximum Shear Stress Ratio = 0.300 : 1 Section used for this span 7x14 Section used for this span 7x14 fb: Actual = 2,647.31 psi fv: Actual = 87.07 psi F'b = 2,850.80psi F'v = 290.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 11.000ft Location of maximum on span = 20.876ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.706 in Ratio = 373 >=360 Span: 1 : L Only Max Upward Transient Deflection 0 in Ratio = 0 <360 n/a Max Downward Total Deflection 1.188 in Ratio = 222 -180 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio = 0 <180 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress atios Moment as ue� -Shear Values Segment Length Span # M V CD CM Ct CLx CIF Cfu C i C r M fb F'b V fv F'v D Only 0.0 0.00 0.0 0.0 Length = 22.0 ft 1 0.419 0.135 0.90 1.00 1.00 1.00 0.983 1.00 1.00 1.00 20.47 1,074.3 2,565.7 2.31 35.3 261.0 +D+L 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 22.0 ft 1 0.929 0.300 1.00 1.00 1.00 1.00 0.983 1.00 1.00 1.00 50.45 2,647.3 2,850.8 5.69 87.1 290.0 +D+0.750L 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 22.0 ft 1 0.633 0.205 1.25 1.00 1.00 1.00 0.983 1.00 1.00 1.00 42.95 2,254.1 3,563.5 4.84 74.1 362.5 +0.60D 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 22.0 ft 1 0.141 0.046 1.60 1.00 1.00 1.00 0.983 1.00 1.00 1.00 12.28 644.6 4,561.3 1.38 21.2 464.0 Project Title: B8/42 Engineer: Kirkland, WA 98034 Project ID: Project Descr: Printed: 21 AUG 2024, 11:11AM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM#2 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L 1 1.1878 11.080 0.0000 0.000 Maximum Deflections for Load Combinations Load Combination Span Max. Downward Defl Location in Span Max. Upward Defl Location in Span D Only 1 0.4819 in 11.080 ft 0.0000 in 0.000 ft +D+L 1 1.1878 in 11.080 ft 0.0000 in 0.000 ft +D+0.750L 1 1.0114 in 11.080 ft 0.0000 in 0.000 ft +0.60D 1 0.2892 in 11.080 ft 0.0000 in 0.000 ft L Only 1 0.7059 in 11.080 ft 0.0000 in 0.000 ft Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Max Upward from all Load Conditions 5.972 5.972 Max Upward from Load Combinations 5.972 5.972 Max Upward from Load Cases 3.550 3.550 D Only 2.422 2.422 +D+L 5.972 5.972 +D+0.750L 5.085 5.085 +0.60D 1.453 1.453 L Only 3.550 3.550 1H 426 6A2 639 11A 1233 15A9 1726 1943 2LH Distara(R) 1)011� I+D+1 I4+6.7S611+6.66D Kirkland, WA 98034 Wood Beam LIC# : KW-06015928, Build:20.23.08.30 DESCRIPTION: BM#2 6 MEhO •3 5 Project Title: Engineer: Project ID: Project Descr: RB Engineers, Inc. B9/42 Printed: 21 AUG 2024, 11 A 1AM Project File: Iron Vista.ec6 (c) ENERCALC INC 1983-2023 2M 426 6,42 8199 111?6 1233 ism OM 11,43 21160 DISW (R) 1 1)01ff I+D+11+D+115011+6.66D 209 6A2 8199 NA 12,93 19A3 LIN DISWO(ft) 1 D0111 I+D+11+D+111M 1+6,661) 1 tNil Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: B 10/42 Printed: 18 JUN 2024, 2:49PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM#3 CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Fb + 2,900.0 psi E : Modulus of Elasticity Load Combination IBC 2021 Fb - 2,900.0 psi Ebend- xx 2,000.Oksi Fc - Prll 2,900.0 psi Eminbend - xx 1,016.54ksi Wood Species iLevel Truss Joist Fc - Perp 750.0 psi Wood Grade Parallam PSL 2.0E Fv 290.0 psi Ft 2,025.0 psi Density 45.070 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0.5) L(0.8) D(0.187) L(0.275) VASMA«11 Span = 23.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0170, L = 0.0250 ksf, Extent = 0.0 -->> 19.0 ft, Tributary Width = 11.0 ft Point Load : D = 0.50, L = 0.80 k @ 19.0 ft DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.566: 1 Maximum Shear Stress Ratio = 0.257 : 1 Section used for this span 7.0 X 14.0 Section used for this span 7.0 X 14.0 fb: Actual = 1,642.89psi fv: Actual = 74.61 psi F'b = 2,903.37psi F'v = 290.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 11.668ft Location of maximum on span = 0.000ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.560 in Ratio = 492 > 360 Span: 1 : L Only Max Upward Transient Deflection 0 in Ratio = 0 <360 n/a Max Downward Total Deflection 0.939 in Ratio = 294 >=180 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio = 0 <180 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V CD CM Ct CLx CIF Cfu C i C r M fb F'b V fv F'v D Only 0.0 0.00 0.0 0.0 Length = 23.0 ft 1 0.253 0.115 0.90 1.00 1.00 1.00 1.001 1.00 1.00 1.00 12.62 662.2 2,613.0 1.97 30.1 261.0 +D+L 1.00 1.00 1.00 1.001 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 23.0 ft 1 0.566 0.257 1.00 1.00 1.00 1.00 1.001 1.00 1.00 1.00 31.31 1,642.9 2,903.4 4.87 74.6 290.0 +D+0.750L 1.00 1.00 1.00 1.001 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 23.0 ft 1 0.385 0.175 1.25 1.00 1.00 1.00 1.001 1.00 1.00 1.00 26.63 1,397.7 3,629.2 4.15 63.5 362.5 +0.60D 1.00 1.00 1.00 1.001 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 23.0 ft 1 0.086 0.039 1.60 1.00 1.00 1.00 1.001 1.00 1.00 1.00 7.57 397.3 4,645.4 1.18 18.1 464.0 Project Title: B 11 /42 Engineer: Kirkland, WA 98034 Project ID: Project Descr: Printed. 18 JUN 2024, 2:49PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM#3 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L 1 0.9385 11.584 0.0000 0.000 Maximum Deflections for Load Combinations Load Combination Span Max. Downward Defl Location in Span Max. Upward Defl Location in Span D Only 1 0.3781 in 11.584 ft 0.0000 in 0.000 ft +D+L 1 0.9385 in 11.584 ft 0.0000 in 0.000 ft +D+0.750L 1 0.7984 in 11.584 ft 0.0000 in 0.000 ft +0.60D 1 0.2268 in 11.584 ft 0.0000 in 0.000 ft L Only 1 0.5605 in 11.584 ft 0.0000 in 0.000 ft Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Max Upward from all Load Conditions 5.378 4.700 Max Upward from Load Combinations 5.378 4.700 Max Upward from Load Cases 3.206 2.819 D Only 2.172 1.881 +D+L 5.378 4.700 +D+0.750L 4.577 3.995 +0.60D 1.303 1.128 L Only 3.206 2.819 612 IN 1113 1331 IM S 131 219 Distara(R) I )01111 Oft I441S011+0100 Kirkland, WA 98034 Wood Beam LIC# : KW-06015928, Build:20.23.08.30 DESCRIPTION: BM#3 Project Title: Engineer: Project ID: Project Descr: RB Engineers, Inc. B 12/42 Printed. 18 JUN 2024, 2:49PM Project File: Iron Vista.ec6 (c) ENERCALC INC 1983-2023 23 446 612 8111 1118 1351 1316 1806 111 ::Pd DIsW (ft) 1 1)01ff I+D+11+D+05011+010D 2I8 445 612 M 1128 1351 2031 2268 Dista�e(ft) 1 D011t I+D+114+01M 14601) 110o11 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: B 13/42 Printed: 20 AUG 2024, 1:48PM Steel Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM#3 CODE REFERENCES Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method Allowable Strength Design Fy : Steel Yield : 50.0 ksi Beam Bracing : Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending b D(0.50) L(0.80) D(0.1870) L(02750) W 12x22 Span = 23.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0170, L = 0.0250 ksf, Extent = 0.0 - > 19.0 ft, Tributary Width = 11.0 ft Point Load : D = 0.50, L = 0.80 k @ 19.0 ft DESIGN SUMMARY Maximum Bending Stress Ratio = 0.428 : 1 Maximum Shear Stress Ratio = 0.084 : 1 Section used for this span W12x22 Section used for this span W12x22 Ma: Applied 31.306 k-ft Va : Applied 5.378 k Mn / Omega: Allowable 73.104 k-ft Vn/Omega : Allowable 63.960 k Load Combination +D+L Load Combination +D+L Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.396 in Ratio = 696 > 360 Span: 1 : L Only Max Upward Transient Deflection 0 in Ratio = 0 <360 n/a Max Downward Total Deflection 0.663 in Ratio = 416 > 180 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio = 0 <180 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stresses Summary of Moment Va ues Su-mmary of Shear Values Seqment Lenqth Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega D Only Dsgn. L = 23.00 ft 1 0.173 0.034 12.62 +D+L Dsgn. L = 23.00 ft 1 0.428 0.084 31.31 +D+0.750L Dsgn. L = 23.00 ft 1 0.364 0.072 26.63 +0.60D Dsgn. L = 23.00 ft 1 0.104 0.020 7.57 Overall Maximum Deflections 12.62 122.08 73.10 1.001.00 31.31 122.08 73.10 1.001.00 26.63 122.08 73.10 1.001.00 7.57 122.08 73.10 1.001.00 Load Combination Span Max. "" Defl Location in Span Load Combination +D+L 1 0.6633 11.566 Vertical Reactions Support notation : Far left is #' Load Combination Support 1 Support 2 Max Upward from all Load Conditions 5.378 4.700 Max Upward from Load Combinations 5.378 4.700 Max Upward from Load Cases 3.206 2.819 D Only 2.172 1.881 2.17 95.94 63.96 5.38 95.94 63.96 4.58 95.94 63.96 1.30 95.94 63.96 Max. "+" Defl Location in Span 0.0000 0.000 Values in KIPS Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: B 14/42 Printed: 20 AUG 2024, 1:48PM Steel Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM#3 Vertical Reactions Support notation : Far left is # Values in KIPS Load Combination Support 1 Support 2 +D+L 5.378 4.700 +D+0.750L 4.577 3.995 +0.60D 1.303 1.128 L Only 3.206 2.819 Steel Section Properties : W12x22 Depth = 12.300 in I xx Web Thick = 0.260 in S xx Flange Width = 4.030 in R xx = Flange Thick = 0.425 in Zx = Area = 6.480 inA2 1 yy = Weight = 22.000 plf S yy = Kdesign = 0.725 in R yy = K1 = 0.625 in Zy = rts = 1.040 in Ycg = 6.150 in 156.00 in^4 J = 0.293 in^4 25.40 inA3 Cw = 164.00 inA6 4.910 in 29.300 inA3 4.660 in^4 2.310 inA3 Wno = 12.000 inA2 0.848 in Sw = 5.120 inA4 3.660 inA3 Qf = 4.760 in^3 Qw = 14.400 inA3 113 453 64 1.0 11,43 1311 16183 1833 1663 tM3 wanca(R) 1 DOoll I+D+11+D+D,191145,6DD Kirkland, WA 98034 Steel Beam LIC# : KW-06015928, Build:20.23.08.30 DESCRIPTION: BM#3 Project Title: Engineer: Project ID: Project Descr: RB Engineers, Inc. B 15/42 Printed: 20 AUG 2024, 1:48PM Project File: Iron Vista.ec6 (c) ENERCALC INC 1983-2023 493 64 9,13 11,43 Rn 16'03 I633 163 wance(R) 1 DOoll I+D+I I0+0101140.601) 2,11 440 6164 IN 11,11 1334 159 INN NN wance(R) 1 Holl I+D+I I047S0114651)110lf Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: B 16/42 Printed: 20 AUG 2024, 1:59PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #4 CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Fb + 2900 psi E : Modulus of Elasticity Load Combination IBC 2021 Fb - 2900 psi Ebend- xx 2000 ksi Fc - Prll 2900 psi Eminbend - xx 1016.535 ksi Wood Species Level Truss Joist Fc - Perp 750 psi Wood Grade Parallam PSL 2.0E Fv 290 psi Ft 2025 psi Density 45.07 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(1.45) L(2.7) D(0.068) L(0.1) v 5.25x14.0 Span = 22.50 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0170, L = 0.0250 ksf, Tributary Width = 4.0 ft Point Load : D = 1.450, L = 2.70 k @ 11.50 ft DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.833 1 Maximum Shear Stress Ratio = 0.269 : 1 Section used for this span 5.25x14.0 Section used for this span 5.25x14.0 fb: Actual = 2,375.58psi fv: Actual = 77.92 psi F'b = 2,850.80psi F'v = 290.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 11.496ft Location of maximum on span = 21.350ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.705 in Ratio = 383 >=360 Span: 1 : L Only Max Upward Transient Deflection 0 in Ratio = 0 <360 n/a Max Downward Total Deflection 1.118 in Ratio = 241 > 240 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio = 0 <240 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress atios Moment as ue� Shear Values Segment Length Span # M V CD CM Ct CLx CIF Cfu C i C r M fb F'b V fv F'v D Only 0.0 0.00 0.0 0.0 Length = 22.50 ft 1 0.340 0.112 0.90 1.00 1.00 1.00 0.983 1.00 1.00 1.00 12.45 871.2 2,565.7 1.43 29.1 261.0 +D+L 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 22.50 ft 1 0.833 0.269 1.00 1.00 1.00 1.00 0.983 1.00 1.00 1.00 33.95 2,375.6 2,850.8 3.82 77.9 290.0 +D+0.750L 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 22.50 ft 1 0.561 0.181 1.25 1.00 1.00 1.00 0.983 1.00 1.00 1.00 28.58 1,999.5 3,563.5 3.22 65.7 362.5 +0.60D 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 22.50 ft 1 0.115 0.038 1.60 1.00 1.00 1.00 0.983 1.00 1.00 1.00 7.47 522.7 4,561.3 0.86 17.5 464.0 Project Title: B 17/42 Engineer: Kirkland, WA 98034 Project ID: Project Descr: Printed: 20 AUG 2024, 1:59PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #4 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L 1 1.1180 11.332 0.0000 0.000 Maximum Deflections for Load Combinations Load Combination Span Max. Downward Defl Location in Span Max. Upward Defl Location in Span D Only 1 0.4131 in 11.332 ft 0.0000 in 0.000 ft +D+L 1 1.1180 in 11.332 ft 0.0000 in 0.000 ft +D+0.750L 1 0.9418 in 11.332 ft 0.0000 in 0.000 ft +0.60D 1 0.2479 in 11.332 ft 0.0000 in 0.000 ft L Only 1 0.7049 in 11.332 ft 0.0000 in 0.000 ft Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Max Upward from all Load Conditions 3.919 4.011 Max Upward from Load Combinations 3.919 4.011 Max Upward from Load Cases 2.445 2.505 D Only 1.474 1.506 +D+L 3.919 4.011 +D+0.750L 3.308 3.385 +0.60D 0.884 0.904 L Only 2.445 2.505 2,14 435 651 1171 11A 1322 15A4 1115 11,11 21H Distara(R) I )0111104 I4+0.1% 1+010D Kirkland, WA 98034 Wood Beam LIC# : KW-06015928, Build:20.23.08.30 DESCRIPTION: BM #4 Project Title: Engineer: Project ID: Project Descr: RB Engineers, Inc. B 18/42 Printed: 20 AUG 2024, 1:59PM Project File: Iron Vista.ec6 (c) ENERCALC INC 1983-2023 M4 435 6,51 8A IIAB IM 6A4 11.66 19V 22,89 DIsW (ft) 1 1)01ff I+D+11+D+050114601) 2114 4,35 6,61 119 ILA 1322 SA 66 9 ' Dista�e(ft) 1 D0111 I+D+114+01M 14661) 110o11 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: B 19/42 Printed: 18 JUN 2024, 2:57PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #5 CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Fb + 2900 psi E : Modulus of Elasticity Load Combination IBC 2021 Fb - 2900 psi Ebend- xx 2000 ksi Fc - Prll 2900 psi Eminbend - xx 1016.535 ksi Wood Species iLevel Truss Joist Fc - Perp 750 psi Wood Grade Parallam PSL 2.0E Fv 290 psi Ft 2025 psi Density 45.07 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(2.3) L(3.4) D(0 068) L(0.1) 5.25x14.0 Span = 16.750 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0170, L = 0.0250 ksf, Tributary Width = 4.0 ft Point Load : D = 2.30, L = 3.40 k @ 8.0 ft DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.72a 1 Maximum Shear Stress Ratio = 0.295 : 1 Section used for this span 5.25x14.0 Section used for this span 5.25x14.0 fb: Actual = 2,076.67psi fv: Actual = 85.50 psi F'b = 2,850.80psi F'v = 290.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 8.008ft Location of maximum on span = 0.000ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.314 in Ratio = 639 >=360 Span: 1 : L Only Max Upward Transient Deflection 0 in Ratio = 0 <360 n/a Max Downward Total Deflection 0.527 in Ratio = 381 > 240 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio = 0 <240 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress atios Moment as ue� Shear Values Segment Length Span # M V CD CM Ct CLx CIF Cfu C i C r M fb F'b V fv F'v D Only 0.0 0.00 0.0 0.0 Length = 16.750 ft 1 0.327 0.132 0.90 1.00 1.00 1.00 0.983 1.00 1.00 1.00 11.98 838.5 2,565.7 1.69 34.5 261.0 +D+L 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 16.750 ft 1 0.728 0.295 1.00 1.00 1.00 1.00 0.983 1.00 1.00 1.00 29.68 2,076.7 2,850.8 4.19 85.5 290.0 +D+0.750L 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 16.750 ft 1 0.496 0.201 1.25 1.00 1.00 1.00 0.983 1.00 1.00 1.00 25.26 1,767.1 3,563.5 3.57 72.8 362.5 +0.60D 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 16.750 ft 1 0.110 0.045 1.60 1.00 1.00 1.00 0.983 1.00 1.00 1.00 7.19 503.1 4,561.3 1.02 20.7 464.0 Project Title: B20/42 Engineer: Kirkland, WA 98034 Project ID: Project Descr: Printed. 18 JUN 2024, 2:57PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #5 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L 1 0.5274 8.314 0.0000 0.000 Maximum Deflections for Load Combinations Load Combination Span Max. Downward Defl Location in Span Max. Upward Defl Location in Span D Only 1 0.2130 in 8.314 ft 0.0000 in 0.000 ft +D+L 1 0.5274 in 8.314 ft 0.0000 in 0.000 ft +D+0.750L 1 0.4488 in 8.314 ft 0.0000 in 0.000 ft +0.60D 1 0.1278 in 8.314 ft 0.0000 in 0.000 ft L Only 1 0.3144 in 8.314 ft 0.0000 in 0.000 ft Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Max Upward from all Load Conditions 4.385 4.129 Max Upward from Load Combinations 4.385 4.129 Max Upward from Load Cases 2.614 2.461 D Only 1.771 1.668 +D+L 4.385 4.129 +D+0.750L 3.731 3.514 +0.60D 1.063 1.001 L Only 2.614 2.461 1.9 324 4H 654 8119 1114 11,41 13.14 1419 1644 Dislara t) 1 D9l111 Oft 1441S111+6.66D Kirkland, WA 98034 Wood Beam LIC# : KW-06015928, Build:20.23.08.30 DESCRIPTION: BM #5 Project Title: Engineer: Project ID: Project Descr: RB Engineers, Inc. 45 2,3 MMER.. ;, -U tz-z •42 B21 /42 Printed. 18 JUN 2024, 2:57PM Project File: Iron Vista.ec6 (c) ENERCALC INC 1983-2023 669 324 489 8S4 Bd9 9M 11,41 0,14 14,11 1844 Dista�ce(ft) 1 1)01ff I+D+114+051114601) 169 324 489 0 8I9 9b4 IIA9 1314 :4 Dista�e(ft) 1 D0111 I+D+114+01M 14661) 110o11 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: B22/42 Printed: 20 AUG 2024, 2:OOPM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #6 CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Fb + 2900 psi Load Combination IBC 2021 Fb - 2900 psi Fc - Prll 2900 psi Wood Species iLevel Truss Joist Fc - Perp 750 psi Wood Grade Parallam PSL 2.0E Fv 290 psi Ft 2025 psi Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0.15) L(0.4) liififfliIIIIlI(Ill 5.25x14.0 Span = 11.50 ft E : Modulus of Elasticity Ebend- xx 2000 ksi Eminbend - xx 1016.535 ksi Density 45.07 pcf Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0170, L = 0.0250 ksf, Extent = 0.0 -->> 8.0 ft, Tributary Width = 7.0 ft Point Load : D = 0.150, L = 0.40 k @ 8.0 ft DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.121: 1 Maximum Shear Stress Ratio = 0.096 : 1 Section used for this span 5.25x14.0 Section used for this span 5.25x14.0 fb: Actual = 344.43psi fv: Actual = 27.92 psi F'b = 2,850.80psi F'v = 290.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 5.792ft Location of maximum on span = 0.000ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.030 in Ratio = 4573 > 360 Span: 1 : L Only Max Upward Transient Deflection 0 in Ratio = 0 <360 n/a Max Downward Total Deflection 0.048 in Ratio = 2847 >=240 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio = 0 <240 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V CD CM Ct CLx CIF Cfu C i C r M fb F'b V fv F'v D Only 0.0 0.00 0.0 0.0 Length = 11.50 ft 1 0.051 0.042 0.90 1.00 1.00 1.00 0.983 1.00 1.00 1.00 1.87 130.6 2,565.7 0.53 10.9 261.0 +D+L 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 11.50 ft 1 0.121 0.096 1.00 1.00 1.00 1.00 0.983 1.00 1.00 1.00 4.92 344.4 2,850.8 1.37 27.9 290.0 +D+0.750L 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 11.50 ft 1 0.082 0.065 1.25 1.00 1.00 1.00 0.983 1.00 1.00 1.00 4.16 290.9 3,563.5 1.16 23.7 362.5 +0.60D 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 11.50 ft 1 0.017 0.014 1.60 1.00 1.00 1.00 0.983 1.00 1.00 1.00 1.12 78.4 4,561.3 0.32 6.5 464.0 Project Title: B23/42 Engineer: Kirkland, WA 98034 Project ID: Project Descr: Printed: 20 AUG 2024, 2:OOPM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #6 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L 1 0.0485 5.750 0.0000 0.000 Maximum Deflections for Load Combinations Load Combination Span Max. Downward Defl Location in Span Max. Upward Defl Location in Span D Only 1 0.0183 in 5.708 ft 0.0000 in 0.000 ft +D+L 1 0.0485 in 5.750 ft 0.0000 in 0.000 ft +D+0.750L 1 0.0409 in 5.750 ft 0.0000 in 0.000 ft +0.60D 1 0.0110 in 5.708 ft 0.0000 in 0.000 ft L Only 1 0.0302 in 5.792 ft 0.0000 in 0.000 ft Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Max Upward from all Load Conditions 1.701 1.201 Max Upward from Load Combinations 1.701 1.201 Max Upward from Load Cases 1.035 0.765 D Only 0.667 0.435 +D+L 1.701 1.201 +D+0.750L 1.443 1.009 +0.60D 0.400 0.261 L Only 1.035 0.765 L09 336 4101 SIR 6J6 14 1102 10116 11,21 Distaace(R) 1 D9lI11+D+11441S011+0101) Kirkland, WA 98034 Wood Beam LIC# : KW-06015928, Build:20.23.08.30 DESCRIPTION: BM #6 ME HP. - M Project Title: Engineer: Project ID: Project Descr: RB Engineers, Inc. B24/42 Printed: 20 AUG 2024, 2:OOPM Project File: Iron Vista.ec6 (c) ENERCALC INC 1983-2023 1A9 t22 336 4141 SIR 6A 710 902 10.16 111n Distaece(R) 1 1)01ff I+D+I 1+D+05011+01CD I'M M 336 W 6l62 6A Distaece(R) 1 D0111 I+D+i I+D+01M 14601) 1 i0o11 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: B25/42 Printed: 19 JUN 2024, 12:39PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #7 CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Fb + 2,400.0 psi Load Combination IBC 2021 Fb - 1,850.0 psi Fc - Prll 1,650.0 psi Wood Species DF/DF Fc - Perp 650.0 psi Wood Grade 24F-V4 Fv 265.0 psi Ft 1,100.0 psi Beam Bracing Beam is Fully Braced against lateral -torsional buckling 0 3.5x9 Span =9.Oft E : Modulus of Elasticity Ebend-xx 1,800.Oksi Eminbend - xx 950.Oksi Ebend-yy 1,600.Oksi Eminbend - yy 850.Oksi Density 31.210 pcf D(0.4) L(0.75) Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0170, L = 0.0250 ksf, Extent = 0.0 -->> 7.0 ft, Tributary Width = 11.0 ft Point Load : D = 0.40, L = 0.750 k @ 7.0 ft DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.570. 1 Maximum Shear Stress Ratio = 0.387 :1 Section used for this span 3.5x9 Section used for this span 3.5x9 fb: Actual = 1,369.15psi fv: Actual = 102.48 psi F'b = 2,400.00 psi F'v = 265.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 4.828ft Location of maximum on span = 7.029ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.127 in Ratio = 852 > 360 Span: 1 : L Only Max Upward Transient Deflection 0 in Ratio = 0 <360 n/a Max Downward Total Deflection 0.208 in Ratio = 518 >=240 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio = 0 <240 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V CD CM Ct CLx Cv Cfu C i C r M fb F'b V fv F'v D Only 0.0 0.00 0.0 0.0 Length = 9.0 ft 1 0.248 0.164 0.90 1.00 1.00 1.00 1.000 1.00 1.00 1.00 2.11 536.5 2,160.0 0.82 39.1 238.5 +D+L 1.00 1.00 1.00 1.000 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 9.0 ft 1 0.570 0.387 1.00 1.00 1.00 1.00 1.000 1.00 1.00 1.00 5.39 1,369.2 2,400.0 2.15 102.5 265.0 +D+0.750L 1.00 1.00 1.00 1.000 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 9.0 ft 1 0.387 0.262 1.25 1.00 1.00 1.00 1.000 1.00 1.00 1.00 4.57 1,161.0 3,000.0 1.82 86.6 331.3 +0.60D 1.00 1.00 1.00 1.000 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 9.0 ft 1 0.084 0.055 1.60 1.00 1.00 1.00 1.000 1.00 1.00 1.00 1.27 321.9 3,840.0 0.49 23.4 424.0 Project Title: B26/42 Engineer: Kirkland, WA 98034 Project ID: Project Descr: Printed: 19 JUN 2024, 12:39PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #7 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L 1 0.2081 4.599 0.0000 0.000 Maximum Deflections for Load Combinations Load Combination Span Max. Downward Defl Location in Span Max. Upward Defl Location in Span D Only 1 0.0814 in 4.566 ft 0.0000 in 0.000 ft +D+L 1 0.2081 in 4.599 ft 0.0000 in 0.000 ft +D+0.750L 1 0.1765 in 4.599 ft 0.0000 in 0.000 ft +0.60D 1 0.0489 in 4.566 ft 0.0000 in 0.000 ft L Only 1 0.1267 in 4.599 ft 0.0000 in 0.000 ft Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Max Upward from all Load Conditions 2.232 2.152 Max Upward from Load Combinations 2.232 2.152 Max Upward from Load Cases 1.343 1.332 D Only 0.889 0.820 +D+L 2.232 2.152 +D+0.750L 1.896 1.819 +0.60D 0.533 0.492 L Only 1.343 1.332 082 111 299 3A9 430 932 8A6 696 189 6,10 Dislara t) 1 D9l111+D+11441S11 1+0.601) Kirkland, WA 98034 Wood Beam LIC# : KW-06015928, Build:20.23.08.30 DESCRIPTION: BM #7 23 ld MM...;: •l�l d3 Project Title: Engineer: Project ID: Project Descr: RB Engineers, Inc. B27/42 Printed: 19 JUN 2024, 12:39PM Project File: Iron Vista.ec6 (c) ENERCALC INC 1983-2023 Ille 111 231 M 434 6t2 lix 636 M6 8J0 DlsWU (R) 1 1)01ff I+D+I 14+05011+0•60D 8I86 1,74 M 3111 08 Q1 6118 136 1I96 im Distaece(k) 1DO,f I+D+iI+D+D•liblI+D,6DDIiOoly Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: B28/42 Printed: 19 JUN 2024, 12:40PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #8 CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Fb + 2,325.0 psi E : Modulus of Elasticity Load Combination IBC 2021 Fb - 2,325.0 psi Ebend- xx 1,550.Oksi Fc - Prll 2,050.0 psi Eminbend - xx 787.82 ksi Wood Species Level Truss Joist Fc - Perp 800.0 psi Wood Grade TimberStrand LSL 1.55E Fv 310.0 psi Ft 1,070.0psi Density 45.010pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling 3.5x 11.875 Span = 8.250 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0140, L = 0.040 ksf, Tributary Width = 14.0 ft DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.403 1 Maximum Shear Stress Ratio = 0.278 : 1 Section used for this span 3.5x11.875 Section used for this span 3.5x11.875 fb: Actual = 938.29psi fv: Actual = 86.26 psi F'b = 2,327.24psi F'v = 310.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 4.125ft Location of maximum on span = 0.000ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.078 in Ratio = 1276 > 480 Span: 1 : L Only Max Upward Transient Deflection 0 in Ratio = 0 <480 n/a Max Downward Total Deflection 0.105 in Ratio = 945> 240 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio = 0 <240 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V CD CM Ct CLx CIF Cfu C i C r M fb F'b V fv F'v D Only 0.0 0.00 0.0 0.0 Length = 8.250 ft 1 0.116 0.080 0.90 1.00 1.00 1.00 1.001 1.00 1.00 1.00 1.67 243.3 2,094.5 0.62 22.4 279.0 +D+L 1.00 1.00 1.00 1.001 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 8.250 ft 1 0.403 0.278 1.00 1.00 1.00 1.00 1.001 1.00 1.00 1.00 6.43 938.3 2,327.2 2.39 86.3 310.0 +D+0.750L 1.00 1.00 1.00 1.001 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 8.250 ft 1 0.263 0.181 1.25 1.00 1.00 1.00 1.001 1.00 1.00 1.00 5.24 764.5 2,909.1 1.95 70.3 387.5 +0.60D 1.00 1.00 1.00 1.001 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 8.250 ft 1 0.039 0.027 1.60 1.00 1.00 1.00 1.001 1.00 1.00 1.00 1.00 146.0 3,723.6 0.37 13.4 496.0 Project Title: B29/42 Engineer: Kirkland, WA 98034 Project ID: Project Descr: Printed: 19 JUN 2024, 12:40PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #8 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L 1 0.1047 4.155 0.0000 0.000 Maximum Deflections for Load Combinations Load Combination Span Max. Downward Defl Location in Span Max. Upward Defl Location in Span D Only 1 0.0271 in 4.155 ft 0.0000 in 0.000 ft +D+L 1 0.1047 in 4.155 ft 0.0000 in 0.000 ft +D+0.750L 1 0.0853 in 4.155 ft 0.0000 in 0.000 ft +0.60D 1 0.0163 in 4.155 ft 0.0000 in 0.000 ft L Only 1 0.0776 in 4.155 ft 0.0000 in 0.000 ft Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Max Upward from all Load Conditions 3.119 3.119 Max Upward from Load Combinations 3.119 3.119 Max Upward from Load Cases 2.310 2.310 D Only 0.809 0.809 +D+L 3.119 3.119 +D+0.750L 2.541 2.541 +0.60D 0.485 0.485 L Only 2.310 2.310 0,15 1.9 N1 35 331 4113 551 630 710 IN Distance (ft) 1 D9l111+D+11441S111+ HAD Kirkland, WA 98034 Wood Beam LIC# : KW-06015928, Build:20.23.08.30 DESCRIPTION: BM #8 32 MEh19ER.- •32 MEMEER- Project Title: Engineer: Project ID: Project Descr: RB Engineers, Inc. B30/42 Printed: 19 JUN 2024, 12:40PM Project File: Iron Vista.ec6 (c) ENERCALC INC 1983-2023 0,J6 Ml 33 397 4.) 6A 120 1.98 DISW (R) 1 1)01ff I+D+I 14+050114601) 016 1.0 MI 322 4m 4S DISWO(R) 1 1)011t I+D+I I+D+616611466D 110oll 6t6 6,41 129 U Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: B31 /42 Printed: 19 JUN 2024, 12:48PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #9 CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Load Combination IBC 2021 Wood Species iLevel Truss Joist Wood Grade MicroLam LVL 2.0 E Beam Bracing : Beam is Fully Braced against lateral -torsional buckling ISM, Fb + 2600 psi E : Modulus of Elasticity Fb - 2600 psi Ebend- xx 2000 ksi Fc - Prll 2510 psi Eminbend - xx 1016.535 ksi Fc - Perp 750 psi Fv 285 psi Ft 1555 psi Density 42.01 pcf L(3.4) D(1.8) L(2.6) L 0.32 5.25x14.0 Span = 11.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0140, L = 0.040 ksf, Tributary Width = 8.0 ft Point Load : D = 2.30, L = 3.40 k @ 5.50 ft Point Load : D = 1.80, L = 2.60 k @ 8.0 ft DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.789 1 Maximum Shear Stress Ratio = 0.567 : 1 Section used for this span 5.25x14.0 Section used for this span 5.25x14.0 fb: Actual = 2,015.79psi fv: Actual = 161.69 psi F'b = 2,555.89psi F'v = 285.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 5.500ft Location of maximum on span = 9.836ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.151 in Ratio = 874 > 480 Span: 1 : L Only Max Upward Transient Deflection 0 in Ratio = 0 <480 n/a Max Downward Total Deflection 0.239 in Ratio = 551 >=240 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio = 0 <240 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V CD CM Ct CLx CIF Cfu C i C r M fb F'b V fv F'v D Only 0.0 0.00 0.0 0.0 Length = 11.0 ft 1 0.326 0.234 0.90 1.00 1.00 1.00 0.983 1.00 1.00 1.00 10.72 750.0 2,300.3 2.94 60.1 256.5 +D+L 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 11.0 ft 1 0.789 0.567 1.00 1.00 1.00 1.00 0.983 1.00 1.00 1.00 28.81 2,015.8 2,555.9 7.92 161.7 285.0 +D+0.750L 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 11.0 ft 1 0.532 0.383 1.25 1.00 1.00 1.00 0.983 1.00 1.00 1.00 24.29 1,699.3 3,194.9 6.68 136.3 356.3 +0.60D 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 11.0 ft 1 0.110 0.079 1.60 1.00 1.00 1.00 0.983 1.00 1.00 1.00 6.43 450.0 4,089.4 1.77 36.1 456.0 Project Title: B32/42 Engineer: Kirkland, WA 98034 Project ID: Project Descr: Printed: 19 JUN 2024, 12:48PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #9 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L 1 0.2393 5.661 0.0000 0.000 Maximum Deflections for Load Combinations Load Combination Span Max. Downward Defl Location in Span Max. Upward Defl Location in Span D Only 1 0.0883 in 5.701 ft 0.0000 in 0.000 ft +D+L 1 0.2393 in 5.661 ft 0.0000 in 0.000 ft +D+0.750L 1 0.2015 in 5.661 ft 0.0000 in 0.000 ft +0.60D 1 0.0530 in 5.701 ft 0.0000 in 0.000 ft L Only 1 0.1509 in 5.661 ft 0.0000 in 0.000 ft Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Max Upward from all Load Conditions 6.426 8.426 Max Upward from Load Combinations 6.426 8.426 Max Upward from Load Cases 4.169 5.351 D Only 2.257 3.075 +D+L 6.426 8.426 +D+0.750L 5.384 7.088 +0.60D 1.354 1.845 L Only 4.169 5.351 IN 2.13 321 Q SIN 6,46 is (E Ud IM Distance (ft) 1 D9l111+D+11441S011+0101) Kirkland, WA 98034 Wood Beam LIC# : KW-06015928, Build:20.23.08.30 DESCRIPTION: BM #9 MEMBER•••:; I .S •9 Project Title: Engineer: Project ID: Project Descr: RB Engineers, Inc. B33/42 Printed: 19 JUN 2024, 12:48PM Project File: Iron Vista.ec6 (c) ENERCALC INC 1983-2023 104 2I3 321 41 SIR 6A6 1d6 143 U2 NA Distaece(ft) 1 1)01ff I+D+11+D+05011+0,60D 104 2I3 3d1 430 636 646 1�6 ! 912 1060 Dista�e(ft) 1 D01I1 I+D+1 I+D+0dM I460D I IOoll Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: B34/42 Printed: 20 AUG 2024, 2:36PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #10 CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Fb + 1700 psi E : Modulus of Elasticity Load Combination IBC 2021 Fb - 1700 psi Ebend- xx 1300 ksi Fc - Prll 1400 psi Eminbend - xx 660.75ksi Wood Species Level Truss Joist Fc - Perp 680 psi Wood Grade TimberStrand LSL 1.3E - Beam/Col Fv 400 psi Ft 1075 psi Density 45.01 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling 3.5x 1 1.875 Span =6.0ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0140, L = 0.040 ksf, Tributary Width = 24.0 ft DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.500. 1 Maximum Shear Stress Ratio = 0.236 : 1 Section used for this span 3.5x11.875 Section used for this span 3.5x11.875 fb: Actual = 850.78psi fv: Actual = 94.23 psi F'b = 1,701.98 psi F'v = 400.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 3.000ft Location of maximum on span = 0.000ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.044 in Ratio = 1623 > 480 Span: 1 : L Only Max Upward Transient Deflection 0 in Ratio = 0 <480 n/a Max Downward Total Deflection 0.060 in Ratio = 1202 > 240 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio = 0 <240 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V CD CM Ct CLx CIF Cfu C i C r M fb F'b V fv F'v D Only 0.0 0.00 0.0 0.0 Length = 6.0 ft 1 0.144 0.068 0.90 1.00 1.00 1.00 1.001 1.00 1.00 1.00 1.51 220.6 1,531.8 0.68 24.4 360.0 +D+L 1.00 1.00 1.00 1.001 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 6.0 ft 1 0.500 0.236 1.00 1.00 1.00 1.00 1.001 1.00 1.00 1.00 5.83 850.8 1,702.0 2.61 94.2 400.0 +D+0.750L 1.00 1.00 1.00 1.001 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 6.0 ft 1 0.326 0.154 1.25 1.00 1.00 1.00 1.001 1.00 1.00 1.00 4.75 693.2 2,127.5 2.13 76.8 500.0 +0.60D 1.00 1.00 1.00 1.001 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 6.0 ft 1 0.049 0.023 1.60 1.00 1.00 1.00 1.001 1.00 1.00 1.00 0.91 132.3 2,723.2 0.41 14.7 640.0 Project Title: B35/42 Engineer: Kirkland, WA 98034 Project ID: Project Descr: Printed: 20 AUG 2024, 2:36PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #10 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L 1 0.0599 3.022 0.0000 0.000 Maximum Deflections for Load Combinations Load Combination Span Max. Downward Defl Location in Span Max. Upward Defl Location in Span D Only 1 0.0155 in 3.022 ft 0.0000 in 0.000 ft +D+L 1 0.0599 in 3.022 ft 0.0000 in 0.000 ft +D+0.750L 1 0.0488 in 3.022 ft 0.0000 in 0.000 ft +0.60D 1 0.0093 in 3.022 ft 0.0000 in 0.000 ft L Only 1 0.0443 in 3.022 ft 0.0000 in 0.000 ft Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Max Upward from all Load Conditions 3.888 3.888 Max Upward from Load Combinations 3.888 3.888 Max Upward from Load Cases 2.880 2.880 D Only 1.008 1.008 +D+L 3.888 3.888 +D+0.750L 3.168 3.168 +0.60D 0.605 0.605 L Only 2.880 2.880 1115 1114 14 Nl) 2A 3A8 4A 464 iZ 5,80 Distara(R) I )01111041441S111+0101) Kirkland, WA 98034 Wood Beam LIC# : KW-06015928, Build:20.23.08.30 DESCRIPTION: BM #10 Project Title: Engineer: Project ID: Project Descr: RB Engineers, Inc. B36/42 Printed: 20 AUG 2024, 2:36PM Project File: Iron Vista.ec6 (c) ENERCALC INC 1983-2023 039 1114 Ida MI) 21H 341 4A 4A Q1 SIR DIsW (ft) 1 1)91hy I+D+I 14+050114601) 0166 1112 IM 23 2'82 333 451 4d0 Dista�e(ft) 1 DO�Iy I+D+I I+D+6,1661 I+6,66D 1IO�ly Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: B37/42 Printed: 20 AUG 2024, 2:47PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #11 CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Load Combination IBC 2021 Wood Species DF/DF Wood Grade 24F-V4 Beam Bracing : Beam is Fully Braced against lateral -torsional buckling Fb + 2400 psi E : Modulus of Elasticity Fb - 1850 psi Ebend- xx 1800 ksi Fc - Prll 1650 psi Eminbend - xx 950 ksi Fc - Perp 650 psi Ebend- yy 1600 ksi Fv 265 psi Eminbend - yy 850 ksi Ft 1100 psi Density 31.21 pcf 0 D(0.1 5.5x12 Span = 12.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0140, L = 0.040 ksf, Tributary Width = 12.0 ft Uniform Load : D = 0.0170, L = 0.0250 ksf, Tributary Width = 4.0 ft DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.556: 1 Maximum Shear Stress Ratio = 0.352 : 1 Section used for this span 5.5x12 Section used for this span 5.5x12 fb: Actual = 1,335.27 psi fv: Actual = 93.40 psi F'b = 2,400.00 psi F'v = 265.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 6.000ft Location of maximum on span = 0.000ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.191 in Ratio = 754 >=480 Span: 1 : L Only Max Upward Transient Deflection 0 in Ratio = 0 <480 n/a Max Downward Total Deflection 0.269 in Ratio = 536 > 240 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio = 0 <240 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress atios Moment Values -Shear as u� Segment Length Span # M V CD CM Ct CLx Cv Cfu C i C r M fb F'b V fv F'v D Only 0.0 0.00 0.0 0.0 Length = 12.0 ft 1 0.179 0.113 0.90 1.00 1.00 1.00 1.000 1.00 1.00 1.00 4.25 386.2 2,160.0 1.19 27.0 238.5 +D+L 1.00 1.00 1.00 1.000 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 12.0 ft 1 0.556 0.352 1.00 1.00 1.00 1.00 1.000 1.00 1.00 1.00 14.69 1,335.3 2,400.0 4.11 93.4 265.0 +D+0.750L 1.00 1.00 1.00 1.000 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 12.0 ft 1 0.366 0.232 1.25 1.00 1.00 1.00 1.000 1.00 1.00 1.00 12.08 1,098.0 3,000.0 3.38 76.8 331.3 +0.60D 1.00 1.00 1.00 1.000 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 12.0 ft 1 0.060 0.038 1.60 1.00 1.00 1.00 1.000 1.00 1.00 1.00 2.55 231.7 3,840.0 0.71 16.2 424.0 Project Title: B38/42 Engineer: Kirkland, WA 98034 Project ID: Project Descr: Printed: 20 AUG 2024, 2:47PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #11 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L 1 0.2686 6.044 0.0000 0.000 Maximum Deflections for Load Combinations Load Combination Span Max. Downward Defl Location in Span Max. Upward Defl Location in Span D Only 1 0.0777 in 6.044 ft 0.0000 in 0.000 ft +D+L 1 0.2686 in 6.044 ft 0.0000 in 0.000 ft +D+0.750L 1 0.2209 in 6.044 ft 0.0000 in 0.000 ft +0.60D 1 0.0466 in 6.044 ft 0.0000 in 0.000 ft L Only 1 0.1909 in 6.044 ft 0.0000 in 0.000 ft Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Max Upward from all Load Conditions 4.896 4.896 Max Upward from Load Combinations 4.896 4.896 Max Upward from Load Cases 3.480 3.480 D Only 1.416 1.416 +D+L 4.896 4.896 +D+0.750L 4.026 4.026 +0.60D 0.850 0.850 L Only 3.480 3.480 1.14 21 350 0161 5161 1106 M 942 ll)H 11A Distara(R) 1 D9l111+D+11441S011+0101) Kirkland, WA 98034 Wood Beam LIC# : KW-06015928, Build:20.23.08.30 DESCRIPTION: BM #11 Project Title: Engineer: Project ID: Project Descr: RB Engineers, Inc. B39/42 Printed: 20 AUG 2024, 2:47PM Project File: Iron Vista.ec6 (c) ENERCALC INC 1983-2023 1114 232 3b0 4,61 5I61 7.5 la +A 11A 1118 Dista�ce(ft) 1 1)01ff I+D+I 14+05001+0,60D 1I4 232 390 469 961 1 63 1060 1L18 Dista�e(ft) 1 D011t I+D+i I+D+01M 14601) 11Ooll Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: B40/42 Printed: 20 AUG 2024, 3:10PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #12 CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2021 Material Properties Analysis Method : Allowable Stress Design Load Combination IBC 2021 Wood Species iLevel Truss Joist Wood Grade Parallam PSL 2.0E Beam Bracing : Beam is Fully Braced against lateral -torsional buckling MO.154) Fb + 2,900.0 psi E : Modulus of Elasticity Fb - 2,900.0 psi Ebend- xx 2,000.Oksi Fc - Prll 2,900.0 psi Eminbend - xx 1,016.54ksi Fc - Perp 750.0 psi Fv 290.0 psi Ft 2,025.0 psi Density 45.070 pcf 5.25x14.0 Span = 12.50 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0650, L = 0.050 ksf, Tributary Width = 6.0 ft Uniform Load : D = 0.0650, L = 0.060 ksf, Tributary Width = 6.0 ft Uniform Load : D = 0.0140, L = 0.040 ksf, Tributary Width = 11.0 ft DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.975 1 Maximum Shear Stress Ratio = 0.731 : 1 Section used for this span 5.25x14.0 Section used for this span 5.25x14.0 fb: Actual = 2,779.70psi fv: Actual = 212.10 psi F'b = 2,850.80psi F'v = 290.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 6.250ft Location of maximum on span = 11.359ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.253 in Ratio = 592 > 480 Span: 1 : L Only Max Upward Transient Deflection 0 in Ratio = 0 <480 n/a Max Downward Total Deflection 0.468 in Ratio = 320 >=240 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio = 0 <240 n/a Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V CD CM Ct CLx CIF Cfu C i C r M fb F'b V fv F'v D Only 0.0 0.00 0.0 0.0 Length = 12.50 ft 1 0.497 0.373 0.90 1.00 1.00 1.00 0.983 1.00 1.00 1.00 18.24 1,276.4 2,565.7 4.77 97.4 261.0 +D+L 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 12.50 ft 1 0.975 0.731 1.00 1.00 1.00 1.00 0.983 1.00 1.00 1.00 39.73 2,779.7 2,850.8 10.39 212.1 290.0 +D+0.750L 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 12.50 ft 1 0.675 0.506 1.25 1.00 1.00 1.00 0.983 1.00 1.00 1.00 34.36 2,403.9 3,563.5 8.99 183.4 362.5 +0.60D 1.00 1.00 1.00 0.983 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 12.50 ft 1 0.168 0.126 1.60 1.00 1.00 1.00 0.983 1.00 1.00 1.00 10.95 765.9 4,561.3 2.86 58.4 464.0 Project Title: B41 /42 Engineer: Kirkland, WA 98034 Project ID: Project Descr: Printed: 20 AUG 2024, 3:10PM Wood Beam Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: BM #12 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L 1 0.4681 6.296 0.0000 0.000 Maximum Deflections for Load Combinations Load Combination Span Max. Downward Defl Location in Span Max. Upward Defl Location in Span D Only 1 0.2149 in 6.296 ft 0.0000 in 0.000 ft +D+L 1 0.4681 in 6.296 ft 0.0000 in 0.000 ft +D+0.750L 1 0.4048 in 6.296 ft 0.0000 in 0.000 ft +0.60D 1 0.1290 in 6.296 ft 0.0000 in 0.000 ft L Only 1 0.2531 in 6.296 ft 0.0000 in 0.000 ft Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Max Upward from all Load Conditions 12.713 12.713 Max Upward from Load Combinations 12.713 12.713 Max Upward from Load Cases 6.875 6.875 D Only 5.838 5.838 +D+L 12.713 12.713 +D+0.750L 10.994 10.994 +0.60D 3.503 3.503 L Only 6.875 6.875 :19 365 48 6111 7,34 8'R 11104 1221 Distara(R) 1 D9l111+D+11441S011+0101) Kirkland, WA 98034 Wood Beam LIC# : KW-06015928, Build:20.23.08.30 DESCRIPTION: BM #12 MEIIPEP IAR I •0�48 Project Title: Engineer: Project ID: Project Descr: RB Engineers, Inc. B42/42 Printed: 20 AUG 2024, 3:10PM Project File: Iron Vista.ec6 (c) ENERCALC INC 1983-2023 1,19 ?42 365 4,88 6111 7.34 is 1604 1227 DiSW(R) 1 1)01ff I+D+I 14+05001+0101) I'll 2R 3.9 01 6'11 134 DISWO(ft) 1 D011t I+D+i I+D+01M 14601) 1 i0o11 Bbi !'. 11,04 1221 F1/7 FOOTING KEY PLAN GENERAL NOTES IR.1 PART El O MTI� III I.R PRRINDT-1. IFF SLAEPON GRADE INSULATION NDIRT,­­ w. F_ PR P. . 1.1 .11111 IN..Tl PRI I IRIRI I M CRAWL SPAC E AOCESS - I RIC I ­RWA­lNNRF70EElI" RIN IMI Al" DREN "AL­ N'_,,__R,R== M UINVENTED CRAWL SPACE DR, F - - - - - - =�I=­.AAUT�o'=T'V VTRaENEDWNG@ s[w F #1 F #2 1& 1, N,,, 'RM, 'CUMUOIUI� %=LGIFA�M YRU NN NEl IRERMEIIN' PER 50 ­E FEET REWIRED, I U.P. 0 Ell FTIP" i I InHD11 = a I JL�� L11-DI -DRP ID14 TE F TOISTEm 1% RE T�g,, 11 � —­14 MPSTEI III llill ni D D 1 3 Of c E7- 1W �A TTIPSTEM: I.El .,D I- )"ITIDII TlIlTz3zsEl: ­��=I�D PAR . TD' P — - - - - - - %lD -IF LA ZIP - - - -it - - - m1D11 dill /A/KU—.� 7 A, CRAWLS _. R PACE R- KAR. LU N -J' 11F.MIREPED L \,TH - - - - - V Lu API 1.PPI.IIFRl DD, ------------ t - - - - - - - - - - - - - - 1� 34R iL -------------------------- SEES PAGES FOR ALL HOLDDOWN INFORMATION ILL ----- -- --------- FIRSTFLO RFOUNDATON FOUNDATION PLAN APPROVED FOR C NETRURI Cm OF EDMONDS F71 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: F2/7 Printed: 21 AUG 2024, 11:02AM General Footing Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: F #1 Code References Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used : IBC 2021 General Information Material Properties Soil Design Values fc : Concrete 28 day strength = 2.50 ksi Allowable Soil Bearing = 2.0 ksf fy : Rebar Yield = 37.0 ksi Soil Density = 110.0 pcf Ec : Concrete Elastic Modulus = 3,122.0 ksi Increase Bearing By Footing Weight = No Concrete Density = 145.0 pcf Soil Passive Resistance (for Sliding) = 250.0 pcf Values Flexure = 0.90 Soil/Concrete Friction Coeff. = 0.30 Shear = 0.750 Increases based on footing Depth Analysis Settings Footing base depth below soil surface = ft Min Steel % Bending Reinf. = Allow press. increase per foot of depth = ksf Min Allow % Temp Reinf. = 0.00180 when footing base is below = ft Min. Overturning Safety Factor = 1.0 : 1 Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension Add Ftg Wt for Soil Pressure Yes Allowable pressure increase per foot of depth Use ftg wt for stability, moments & shears Yes = ksf Add Pedestal Wt for Soil Pressure No when max. length or width is greater than = ft Use Pedestal wt for stability, mom & shear No Dimensions Width parallel to X-X Axis = 4.0 ft Length parallel to Z-Z Axis = 4.0 ft Footing Thickness = 12.0 in Pedestal dimensions... px : parallel to X-X Axis pz : parallel to Z-Z Axis =_ Height Rebar Centerline to Edge of Concrete... at Bottom of footing = Reinforcing Bars parallel to X-X Axis Number of Bars Reinforcing Bar Size = # Bars parallel to Z-Z Axis Number of Bars = Reinforcing Bar Size = # Bandwidth Distribution Check (ACI 15.4.4.2) Direction Requiring Closer Separation # Bars required within zone # Bars required on each side of zone Applied Loads P : Column Load OB : Overburden M-xx M-zZ V-x V-z D 10.60 X 3.0 in 6 4 6 4 6-#4Bars X-X Section Looking to +Z n/a n/a n/a Lr L S 13.40 Z X V N_ 21 N O 6-#4Bars M Z-Z Section Looking to +X W E H k ksf k-ft k-ft k k Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: F3/7 Printed: 21 AUG 2024, 11:02AM General Footing Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: F #1 DESIGN SUMMARY - . • Min. Ratio Item Applied Capacity Governing Load Combination PASS 0.8225 Soil Bearing 1.645 ksf 2.0 ksf +D+L about Z-Z axis PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding PASS n/a Uplift 0.0 k 0.0 k No Uplift PASS 0.5840 Z Flexure (+X) 4.270 k-ft/ft 7.311 k-ft/ft +1.20D+1.60L PASS 0.5840 Z Flexure (-X) 4.270 k-ft/ft 7.311 k-ft/ft +1.20D+1.60L PASS 0.5840 X Flexure (+Z) 4.270 k-ft/ft 7.311 k-ft/ft +1.20D+1.60L PASS 0.5840 X Flexure (-Z) 4.270 k-ft/ft 7.311 k-ft/ft +1.20D+1.60L PASS 0.3268 1-way Shear (+X) 24.513 psi 75.0 psi +1.20D+1.60L PASS 0.3268 1-way Shear (-X) 24.513 psi 75.0 psi +1.20D+1.60L PASS 0.3268 1-way Shear (+Z) 24.513 psi 75.0 psi +1.20D+1.60L PASS 0.3268 1-way Shear (-Z) 24.513 psi 75.0 psi +1.20D+1.60L PASS 0.6801 2-way Punching 102.016 psi 150.0 psi +1.20D+1.60L Detailed Results Soil Bearing Rotation Axis & Xecc Zecc Actual Soil Bearing Stress @ Location Actual / Allow Load Combination... Gross Allowable (in) Bottom, -Z Top, +Z Left, -X Right, +X Ratio X-X, D Only 2.0 n/a 0.0 0.8075 0.8075 n/a n/a 0.404 X-X, +D+L 2.0 n/a 0.0 1.645 1.645 n/a n/a 0.823 X-X, +D+0.750L 2.0 n/a 0.0 1.436 1.436 n/a n/a 0.718 X-X, +0.60D 2.0 n/a 0.0 0.4845 0.4845 n/a n/a 0.242 Z-Z, D Only 2.0 0.0 n/a n/a n/a 0.8075 0.8075 0.404 Z-Z, +D+L 2.0 0.0 n/a n/a n/a 1.645 1.645 0.823 Z-Z, +D+0.750L 2.0 0.0 n/a n/a n/a 1.436 1.436 0.718 Z-Z, +0.60D 2.0 0.0 n/a n/a n/a 0.4845 0.4845 0.242 Overturning Stability Rotation Axis & Load Combination... Overturning Moment Resisting Moment Stability Ratio Status Footing Has NO Overturning Sliding Stability All units k Force Application Axis Load Combination... Sliding Force Resisting Force Stability Ratio Status Footing Has NO Sliding Footing Flexure Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status k-ft Surface in^2 in^2 in^2 k-ft X-X, +1.40D 1.855 +Z Bottom 0.2592 AsMin 0.30 7.311 OK X-X, +1.40D 1.855 -Z Bottom 0.2592 AsMin 0.30 7.311 OK X-X, +1.20D+1.60L 4.270 +Z Bottom 0.2592 AsMin 0.30 7.311 OK X-X, +1.20D+1.60L 4.270 -Z Bottom 0.2592 AsMin 0.30 7.311 OK X-X, +1.20D+0.50L 2.428 +Z Bottom 0.2592 AsMin 0.30 7.311 OK X-X, +1.20D+0.50L 2.428 -Z Bottom 0.2592 AsMin 0.30 7.311 OK X-X, +1.20D 1.590 +Z Bottom 0.2592 AsMin 0.30 7.311 OK X-X, +1.20D 1.590 -Z Bottom 0.2592 AsMin 0.30 7.311 OK X-X, +0.90D 1.193 +Z Bottom 0.2592 AsMin 0.30 7.311 OK X-X, +0.90D 1.193 -Z Bottom 0.2592 AsMin 0.30 7.311 OK Z-Z, +1.40D 1.855 -X Bottom 0.2592 AsMin 0.30 7.311 OK Z-Z, +1.40D 1.855 +X Bottom 0.2592 AsMin 0.30 7.311 OK Z-Z, +1.20D+1.60L 4.270 -X Bottom 0.2592 AsMin 0.30 7.311 OK Z-Z, +1.20D+1.60L 4.270 +X Bottom 0.2592 AsMin 0.30 7.311 OK Z-Z, +1.20D+0.50L 2.428 -X Bottom 0.2592 AsMin 0.30 7.311 OK Z-Z, +1.20D+0.50L 2.428 +X Bottom 0.2592 AsMin 0.30 7.311 OK Z-Z, +1.20D 1.590 -X Bottom 0.2592 AsMin 0.30 7.311 OK Kirkland, WA 98034 Project Title: F4/7 Engineer: Project ID: Project Descr: Printed: 21 AUG 2024, 11:02AM General Footing i = Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: F #1 Footing Flexure Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status k-ft Surface in^2 in^2 in^2 k-ft Z-Z, +1.201D 1.590 +X Bottom 0.2592 AsMin 0.30 7.311 OK Z-Z, +0.90D 1.193 -X Bottom 0.2592 AsMin 0.30 7.311 OK Z-Z, +0.90D 1.193 +X Bottom 0.2592 AsMin 0.30 7.311 OK One Way Shear Load Combination... Vu @ -X Vu @ +X Vu @ -Z Vu @ +Z Vu:Max Phi Vn Vu / Phi*Vn Status +1.40D 10.65 psi 10.65 psi 10.65 psi 10.65 psi 10.65 psi 75.00 psi 0.14 OK +1.20D+1.60L 24.51 psi 24.51 psi 24.51 psi 24.51 psi 24.51 psi 75.00 psi 0.33 OK +1.20D+0.50L 13.94 psi 13.94 psi 13.94 psi 13.94 psi 13.94 psi 75.00 psi 0.19 OK +1.20D 9.13 psi 9.13 psi 9.13 psi 9.13 psi 9.13 psi 75.00 psi 0.12 OK +0.90D 6.85 psi 6.85 psi 6.85 psi 6.85 psi 6.85 psi 75.00 psi 0.09 OK Two -Way "Punching" Shear All units k Load Combination... Vu Phi*Vn Vu / Phi*Vn Status +1.40D 44.32 psi 150.00psi 0.2955 OK +1.20D+1.60L 102.02 psi 150.00psi 0.6801 OK +1.20D+0.50L 58.00 psi 150.00psi 0.3866 OK +1.20D 37.99 psi 150.00psi 0.2532 OK +0.90D 28.49 psi 150.00psi 0.1899 OK Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: F5/7 Printed: 21 AUG 2024, 11:05AM General Footing Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: F #2 Code References Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used : IBC 2021 General Information Material Properties Soil Design Values fc : Concrete 28 day strength = 2.50 ksi Allowable Soil Bearing = 2.0 ksf fy : Rebar Yield = 37.0 ksi Soil Density = 110.0 pcf Ec : Concrete Elastic Modulus = 3,122.0 ksi Increase Bearing By Footing Weight = No Concrete Density = 145.0 pcf Soil Passive Resistance (for Sliding) = 250.0 pcf Values Flexure = 0.90 Soil/Concrete Friction Coeff. = 0.30 Shear = 0.750 Increases based on footing Depth Analysis Settings Footing base depth below soil surface = ft Min Steel % Bending Reinf. = Allow press. increase per foot of depth = ksf Min Allow % Temp Reinf. = 0.00180 when footing base is below = ft Min. Overturning Safety Factor = 1.0 : 1 Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension Add Ftg Wt for Soil Pressure Yes Allowable pressure increase per foot of depth Use ftg wt for stability, moments & shears Yes = ksf Add Pedestal Wt for Soil Pressure No when max. length or width is greater than = ft Use Pedestal wt for stability, mom & shear No Dimensions Width parallel to X-X Axis = 3.0 ft Length parallel to Z-Z Axis = 3.0 ft Footing Thickness = 12.0 in Pedestal dimensions... X px : parallel to X-X Axis = in q pz : parallel to Z-Z Axis =_ in Height in Rebar Centerline to Edge of Concrete... at Bottom of footing = 3.0 in Reinforcing Bars parallel to X-X Axis Number of Bars Reinforcing Bar Size = # Bars parallel to Z-Z Axis Number of Bars = Reinforcing Bar Size = # Bandwidth Distribution Check (ACI 15.4.4.2) Direction Requiring Closer Separation # Bars required within zone # Bars required on each side of zone Applied Loads P : Column Load OB : Overburden M-xx M-zz V-x V-z D 5.80 4.0 4 Z 4 4 4-#4Bars 4-#4Bars Q M ih X-X Section Looking to +Z Z-Z Section Looking to +X n/a n/a n/a Lr L S W E H 6.70 k ksf k-ft k-ft k k Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: F6/7 Printed: 21 AUG 2024, 11:05AM General Footing Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: F #2 DESIGN SUMMARY - . • Min. Ratio Item Applied Capacity Governing Load Combination PASS 0.7670 Soil Bearing 1.534 ksf 2.0 ksf +D+L about Z-Z axis PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding PASS n/a Uplift 0.0 k 0.0 k No Uplift PASS 0.3391 Z Flexure (+X) 2.210 k-ft/ft 6.517 k-ft/ft +1.20D+1.60L PASS 0.3391 Z Flexure (-X) 2.210 k-ft/ft 6.517 k-ft/ft +1.20D+1.60L PASS 0.3391 X Flexure (+Z) 2.210 k-ft/ft 6.517 k-ft/ft +1.20D+1.60L PASS 0.3391 X Flexure (-Z) 2.210 k-ft/ft 6.517 k-ft/ft +1.20D+1.60L PASS 0.1819 1-way Shear (+X) 13.642 psi 75.0 psi +1.20D+1.60L PASS 0.1819 1-way Shear (-X) 13.642 psi 75.0 psi +1.20D+1.60L PASS 0.1819 1-way Shear (+Z) 13.642 psi 75.0 psi +1.20D+1.60L PASS 0.1819 1-way Shear (-Z) 13.642 psi 75.0 psi +1.20D+1.60L PASS 0.3410 2-way Punching 51.157 psi 150.0 psi +1.20D+1.60L Detailed Results Soil Bearing Rotation Axis & Xecc Zecc Actual Soil Bearing Stress @ Location Actual / Allow Load Combination... Gross Allowable (in) Bottom, -Z Top, +Z Left, -X Right, +X Ratio X-X, D Only 2.0 n/a 0.0 0.7894 0.7894 n/a n/a 0.395 X-X, +D+L 2.0 n/a 0.0 1.534 1.534 n/a n/a 0.767 X-X, +D+0.750L 2.0 n/a 0.0 1.348 1.348 n/a n/a 0.674 X-X, +0.60D 2.0 n/a 0.0 0.4737 0.4737 n/a n/a 0.237 Z-Z, D Only 2.0 0.0 n/a n/a n/a 0.7894 0.7894 0.395 Z-Z, +D+L 2.0 0.0 n/a n/a n/a 1.534 1.534 0.767 Z-Z, +D+0.750L 2.0 0.0 n/a n/a n/a 1.348 1.348 0.674 Z-Z, +0.60D 2.0 0.0 n/a n/a n/a 0.4737 0.4737 0.237 Overturning Stability Rotation Axis & Load Combination... Overturning Moment Resisting Moment Stability Ratio Status Footing Has NO Overturning Sliding Stability All units k Force Application Axis Load Combination... Sliding Force Resisting Force Stability Ratio Status Footing Has NO Sliding Footing Flexure Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status k-ft Surface in^2 in^2 in^2 k-ft X-X, +1.40D 1.015 +Z Bottom 0.2592 AsMin 0.2667 6.517 OK X-X, +1.40D 1.015 -Z Bottom 0.2592 AsMin 0.2667 6.517 OK X-X, +1.20D+1.60L 2.210 +Z Bottom 0.2592 AsMin 0.2667 6.517 OK X-X, +1.20D+1.60L 2.210 -Z Bottom 0.2592 AsMin 0.2667 6.517 OK X-X, +1.20D+0.50L 1.289 +Z Bottom 0.2592 AsMin 0.2667 6.517 OK X-X, +1.20D+0.50L 1.289 -Z Bottom 0.2592 AsMin 0.2667 6.517 OK X-X, +1.20D 0.870 +Z Bottom 0.2592 AsMin 0.2667 6.517 OK X-X, +1.20D 0.870 -Z Bottom 0.2592 AsMin 0.2667 6.517 OK X-X, +0.90D 0.6525 +Z Bottom 0.2592 AsMin 0.2667 6.517 OK X-X, +0.90D 0.6525 -Z Bottom 0.2592 AsMin 0.2667 6.517 OK Z-Z, +1.40D 1.015 -X Bottom 0.2592 AsMin 0.2667 6.517 OK Z-Z, +1.40D 1.015 +X Bottom 0.2592 AsMin 0.2667 6.517 OK Z-Z, +1.20D+1.60L 2.210 -X Bottom 0.2592 AsMin 0.2667 6.517 OK Z-Z, +1.20D+1.60L 2.210 +X Bottom 0.2592 AsMin 0.2667 6.517 OK Z-Z, +1.20D+0.50L 1.289 -X Bottom 0.2592 AsMin 0.2667 6.517 OK Z-Z, +1.20D+0.50L 1.289 +X Bottom 0.2592 AsMin 0.2667 6.517 OK Z-Z, +1.20D 0.870 -X Bottom 0.2592 AsMin 0.2667 6.517 OK Kirkland, WA 98034 Project Title: F7/7 Engineer: Project ID: Project Descr: Printed: 21 AUG 2024, 11:05AM General Footing i = Project File: Iron Vista.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: F #2 Footing Flexure Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status k-ft Surface in^2 in^2 in^2 k-ft Z-Z, +1.201D 0.870 +X Bottom 0.2592 AsMin 0.2667 6.517 OK Z-Z, +0.90D 0.6525 -X Bottom 0.2592 AsMin 0.2667 6.517 OK Z-Z, +0.90D 0.6525 +X Bottom 0.2592 AsMin 0.2667 6.517 OK One Way Shear Load Combination... Vu @ -X Vu @ +X Vu @ -Z Vu @ +Z Vu:Max Phi Vn Vu / Phi*Vn Status +1.40D 6.27 psi 6.27 psi 6.27 psi 6.27 psi 6.27 psi 75.00 psi 0.08 OK +1.20D+1.60L 13.64 psi 13.64 psi 13.64 psi 13.64 psi 13.64 psi 75.00 psi 0.18 OK +1.20D+0.50L 7.96 psi 7.96 psi 7.96 psi 7.96 psi 7.96 psi 75.00 psi 0.11 OK +1.20D 5.37 psi 5.37 psi 5.37 psi 5.37 psi 5.37 psi 75.00 psi 0.07 OK +0.90D 4.03 psi 4.03 psi 4.03 psi 4.03 psi 4.03 psi 75.00 psi 0.05 OK Two -Way "Punching" Shear All units k Load Combination... Vu Phi*Vn Vu / Phi*Vn Status +1.40D 23.50 psi 150.00psi 0.1566 OK +1.20D+1.60L 51.16 psi 150.00psi 0.341 OK +1.20D+0.50L 29.83 psi 150.00psi 0.1989 OK +1.20D 20.14 psi 150.00psi 0.1343 OK +0.90D 15.10 psi 150.00psi 0.1007 OK Kirkland, WA 98033 Project Title: Engineer: Project ID: Project Descr: R 1 /36 Printed: 9 OCT 2023, 10:19AM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RIB Engineers, Inc. (c) ENERCALC INC 1983-2023 (2)#4's CONT. TOP #4's @ 10" HORIZ. "b" BARS (GR.40 OR-- 60) FULL HT. VERT. CONTACT LAP SPLICE TYP. "L" PER SCHEDULE 2'-6" 3'-6" #4x "C" BARS x Q 24" O.C. 8 \ PER SCHEDULE 6 THIS DOWEL MAY BE " CONC. SLAB -,DRILLED & EPDXIED 4 4" W.W.M. INTO FOOTING. ._J (6x6-10x10) "_J #4 @ 12" O.C. g (T&B) AS SHOWN) FINISH GRADE (CONTRACTOR VERIFY) FREE DRAINING GRAVEL BACK FILL PER SOIL ENGINEER TO MINIMUM OF 12" OF FINISHED GRADE. 2x4 CONT. KEY \ SPRAYED ON DAMP/WATER PROOFING �X DRAINBOARD FROM TOP OF FOOTING TO FINISH GRADE TYP. PER SOILS 6" HOOK ENGINEER. UNYIELDING SOIL 4" DIA. PVC PERF. PIPE COMPACT SOIL W IN WASHED GRAVEL TO DAYLIGHT PER SOILS ENGINEER. "a" BARS d "L" DOWELS "L" SHAPED RETAINING WALL RETAINING WALL NOTES: 1. 2,000 PSF SOIL BEARING, 0.4 CO. OF FRICTION (ASSUMED) 2. 35 PCF EQUIV. FLUID PRESSURE, 250 PCF PASSIVE PRESSURE.(ASSUMED) 3. 2,500 PSI CONCRETE. 4. GRADE 40 OR 60 REINF. 5. CONTRACTOR SHALL VERIFY ALL EXISTING & FINISH GRADES PRIOR TO CONSTRUCTION. 6. REINFORCING SHALL BE INSPECTED POURING CONCRETE. 7. BUILDING INSPECTOR/SOILS ENGINEER TO INSPECT & APPROVE SOILS BELOW FOOTING PRIOR TO CONSTRUCTION OF FOOTINGS. 8. THIS DESIGN SHALL NOT BE CONSTRUCTED ON SILT OR CLAY BEARING SOILS, OR WITH SILT OR CLAY BACKFILL BEHIND WALLS. 9. CONTRACTOR SHALL COMPLY WITH ALL O.S.H.A. & W.I.S.H.A. HEALTH & SAFETY STANDARDS. 10. BACKFILL SHOULD BE PLACED WITH EXTREME CARE TO AVOID EXCESSIVE HORIZONTAL LOADS ON THE WALL. THIS REQUIREMENT SHOULD TAKE PRECEDENCE OVER COMPLETE ADHERENCE TO THE COMPACTION CRITERIA. IMPORTANT NOTES: 1. CONTRACTOR MAY BACKFILL "H"/3 MAX. BEHIND WALLS PRIOR TO PLACEMENT OF SLAB ON GRADE. 2. CONTRACTOR MAY NOT FULLY BACKFILL BEHIND WALL UNTIL REINF. SLAB IS IN PLACE & CURED. RETAINING WALL SCHEDULE 'H' wv.rr. 'W' 5' 2-0' #4@9' #4@9' #4@9' 3'-G' 8' 8' 7' 3-0' #4@8' #4@8' #4@8' 4-0' 8' 10' 9' 4-0' #5@12' #5212' #5@12' 4'-6' 8' 10' 11' 5-0' #5@10' #5@10' #5@10' 5-0' 8' 10' 13' 6'-0' #5@8' #5@8' #5@8' 5'-6' 11 10" Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R2/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L Shape Ret Wall 5' to bottom of Ftg W/ Slab Code Reference: Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Soil Data Retained Height = 4.00 ft Allow Soil Bearing = 2,000.0 psf Wall height above soil = 0.50 ft Equivalent Fluid Pressure Method Active Heel Pressure - 35.0 psf/ft Slope Behind Wall = 0.00 Height of Soil over Toe = 4.00 in = Water table above Passive Pressure = 250.0 psf/ft bottom of footing = 0.0 ft Soil Density, Heel = 120.00 pcf Soil Density, Toe = 120.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 0.00 in Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem __ 0.0 psf (Service Level) Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall = 0.0 ft Poisson's Ratio = 0.350 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R3/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L Shape Ret Wall F to bottom of Ftg W/ Slab Design Summary Stem Construction Bottom Stem OK Design Height Above Ftg ft = 0.00 Wall Stability Ratios Wall Material Above "Ht" = Concrete Overturning = 2.06 OK Design Method = SD Slab Resists All Sliding ! Thickness = 8.00 Global Stability = 2.53 Rebar Size = # 4 Rebar Spacing = 9.00 Total Bearing Load = 1,013 Ibs Rebar Placed at = Edge ...resultant ecc. = 0.40 in Design Data Eccentricity within middle third fb/FB + fa/Fa = 0.077 Soil Pressure @ Toe = 443 psf OK Total Force @ Section Soil Pressure @ Heel = 361 psf OK Service Level Ibs = Allowable = 2,000 psf Strength Level Ibs = 280.0 Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 620 psf Service Level ft-#= ACI Factored @ Heel = 506 psf Strength Level ft-# = 373.3 Footing Shear @ Toe = 2.5 psi OK Moment..... Allowable = 4,832.2 Footing Shear @ Heel = 1.8 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = Sliding Calcs Strength Level psi = 3.7 Lateral Sliding Force = 437.5 Ibs Shear..... Allowable psi = 45.8 Anet (Masonry) in2 = Wall Weight psf= 100.0 Rebar Depth 'd' in = 6.25 Masonry Data Vertical component of active lateral soil pressure IS f'm psi = considered in the calculation of soil bearing pressures. Fs psi = Solid Grouting = Load Factors Modular Ratio 'n' _ Building Code Equiv. Solid Thick. _ Dead Load 1.000 Masonry Block Type = Live Load 1.000 Masonry Design Method = ASD Earth, H 1.000 Concrete Data Wind, W 1.000 f'c psi= 2,500.0 Seismic, E 1.000 Fy psi = 40,000.0 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R4/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L Shape Ret Wall 5' to bottom of Ftg W/ Slab Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) : 0.021 in2/ft 0.0018bh : 0.0018(12)(8) : 0.1728 in2/ft Horizontal Reinforcing Options One layer of : Two layers of Required Area : 0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area : 0.2667 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area : 1.27 in2/ft #6@ 27.50 in #6@ 55.00 in Footing Data Footing Design Results Toe Width = 1.33 ft Toe Heel Heel Width = 0.67 Factored Pressure = 620 506 psf Total Footing Width = 2.00 Mu': Upward = 526 0 ft-# Footing Thickness = 12.00 in Mu': Downward = 168 0 ft-# Mu: Design = 358 OK 0 ft-# OK Key Width = 0.00 in phiMn = 6,834 OK - Flush Key Depth = 0.00 in Actual 1-Way Shear = 2.51 1.85 psi Key Distance from Toe = 0.00 ft Allow 1-Way Shear = 75.00 75.00 psi f'c = 2,500 psi Fy = 40,000 psi Toe Reinforcing = # 4 @ 9.00 in Footing Concrete Density = 150.00 pcf Heel Reinforcing = Flush heel condition. No reinforcing required. Min. As % = 0.0018 Key Reinforcing = None Spec'd Cover @ Top 2.00 @ Btm = 3.00 in Footing Torsion, Tu = 0.00 ft-Ibs Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: #4@ 9.25 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.77 in, #8@ 36.57 in, #9@ 46.29 in, #10@ 58.79 in Heel: Flush heel condition. No reinforcing required. Key: No key defined Min footing T&S reinf Area 0.52 in2 Min footing T&S reinf Area per foot 0.26 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R5/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L Shape Ret Wall 5' to bottom of Ftg W/ Slab Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Item Ibs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 437.5 1.67 Total = 437.5 O.T.M. = Resisting/Overturning Ratio = 2.06 Vertical Loads used for Soil Pressure = 1,013.4 Ibs .....RESISTING..... Force Distance Moment Ibs ft ft-# 729.2 Soil Over HL (ab. water tbl) 0.0 2.00 0.0 Soil Over HL (bel. water tbl) 2.00 0.0 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem = Soil Over Toe = 53.2 0.67 35.4 Surcharge Over Toe = Stem Weight(s) = 450.0 1.66 748.5 Earth @ Stem Transitions= 729.2 Footing Weight = 299.5 1.00 299.0 Key Weight = Vert. Component = 210.7 2.00 420.7 Total = 1,013.4 Ibs R.M.= 1,503.6 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Tor) of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.028 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R6/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L Shape Ret Wall F to bottom of Ftg W/ Slab Rebar Lap & Embedment Lengths Information Stem Design Segment: Bottom Stem Design Height: 0.00 ft above top of footing Lap Splice length for #4 bar specified in this stem design segment (25.4.2.4a) = 15.60 in Development length for #4 bar specified in this stem design segment = 12.00 in Hooked embedment length into footing for #4 bar specified in this stem design segment = 0.00 in As Provided = 0.2667 in2/ft As Required = 0.1728 in2/ft Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. DESCRIPTION: L Shape Ret Wall 5' to bottom of Ftg W/ Slab Ell 8" w/ #4 @ 9" #4@9in @ Toe #4@9" @ Heel R7/36 Printed: 14 MAY 2024, 5:03PM Project File: L-Shaped Retaining Wall 2000 psf.ec6 3" (c) ENERCALC INC 1983-2023 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. DESCRIPTION: L Shape Ret Wall 5' to bottom of Ftg W/ Slab Re n c') _Q- N � Cl) 438# R8/36 Printed: 14 MAY 2024, 5:03PM Project File: L-Shaped Retaining Wall 2000 psf.ec6 (c) ENERCALC INC 1983-2023 ■ Lateral earth pressure due to the soil BELOW water table Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R9/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall T to bottom of Ftg W/ slab Code Reference: Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height - 6.00 ft Wall height above soil = 0.50 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 4.00 in Water table above bottom of footing = 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Soil Data Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 250.0 psf/ft Soil Density, Heel = 120.00 pcf Soil Density, Toe = 120.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem __ 0.0 psf (Service Level) Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall = 0.0 ft Poisson's Ratio = 0.350 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R10/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall T to bottom of Ftg W/ slab Design Summary Stem Construction Design Height Above Ftg Wall Stability Ratios Wall Material Above "Ht" Overturning = 1.93 OK Design Method Slab Resists All Sliding ! Thickness Global Stability = 1.99 Rebar Size Rebar Spacing Total Bearing Load = 1,677 Ibs Rebar Placed at ...resultant ecc. = 0.31 in Design Data Eccentricity within middle third fb/FB + fa/Fa Soil Pressure @ Toe = 443 psf OK Total Force @ Section Soil Pressure @ Heel = 400 psf OK Service Level Allowable = 2,000 psf Strength Level Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 620 psf Service Level ACI Factored @ Heel = 560 psf Strength Level Footing Shear @ Toe = 5.9 psi OK Moment..... Allowable Footing Shear @ Heel = 6.2 psi OK Allowable = 75.0 psi Shear.. ual Service ce Level l Sliding Calcs Strength Level Lateral Sliding Force = 857.5 Ibs Shear..... Allowable Anet (Masonry) Wall Weight Rebar Depth 'd' Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors Building Code Dead Load 1.000 Live Load 1.000 Earth, H 1.000 Wind, W 1.000 Seismic, E 1.000 Masonry Data f'm Fs Solid Grouting Modular Ratio 'n' Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data f'c Fy Bottom Stem OK ft = 0.00 = Concrete SD 6.00 # 4 8.00 Edge 0.348 Ibs = Ibs = 630.0 ft-# _ ft-# = 1,260.0 3,612.6 psi = psi = 12.4 psi = 54.2 in2 = psf = 75.0 in = 4.25 psi = psi = ASD psi = 2,500.0 psi = 40,000.0 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R11 /36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall T to bottom of Ftg W/ slab Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) : 0.1068 in2/ft 0.0018bh : 0.0018(12)(6) : 0.1296 in2/ft Horizontal Reinforcing Options One layer of : Two layers of Required Area : 0.1296 in2/ft #4@ 16.67 in #4@ 33.33 in Provided Area : 0.3 in2/ft #5@ 25.83 in #5@ 51.67 in Maximum Area : 0.8636 in2/ft #6@ 36.67 in #6@ 73.33 in Footing Data Footing Design Results Toe Width = 2.17 ft Toe Heel Heel Width = 0.83 Factored Pressure = 620 560 psf Total Footing Width = 3.00 Mu': Upward = 1,420 0 ft-# Footing Thickness = 12.00 in Mu': Downward = 446 186 ft-# Mu: Design = 975 OK 186 ft-# OK Key Width = 0.00 in phiMn = 7,663 8,563ft-# Key Depth = 0.00 in Actual 1-Way Shear = 5.94 6.16 psi Key Distance from Toe = 0.00 ft Allow 1-Way Shear = 75.00 75.00 psi f'c = 2,500 psi Fy = 40,000 psi Toe Reinforcing = # 4 @ 8.00 in Footing Concrete Density = 150.00 pcf Heel Reinforcing = # 4 @ 8.00 in Min. As % = 0.0018 Key Reinforcing = None Spec'd Cover @ Top 2.00 @ Btm = 3.00 in Footing Torsion, Tu = 0.00 ft-Ibs Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: #4@ 9.25 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.77 in, #8@ 36.57 in, #9@ 46.29 in, #10@ 58.79 in Heel: #4@ 9.25 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.77 in, #8@ 36.57 in, #9@ 46.29 in, #10@ 58.79 in Key: No key defined Min footing T&S reinf Area 0.78 in2 Min footing T&S reinf Area per foot 0.26 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R12/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall T to bottom of Ftg W/ slab Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# HL Act Pres (ab water tbl) 857.5 2.33 2,000.8 Soil Over HL (ab. water tbl) 239.8 2.83 679.1 HL Act Pres (be water tbl) Soil Over HL (bel. water tbl) 2.83 679.1 Hydrostatic Force Water Table Buoyant Force = Sloped Soil Over Heel = Surcharge over Heel = Surcharge Over Heel = Surcharge Over Toe = Adjacent Footing Load = Adjacent Footing Load = Axial Dead Load on Stem = Added Lateral Load = ' Axial Live Load on Stem = Load @ Stem Above Soil = Soil Over Toe = 86.6 1.08 93.8 = Surcharge Over Toe = Stem Weight(s) = 487.5 2.42 1,177.8 Earth @ Stem Transitions= Total = 857.5 O.T.M. = 2,000.8 Footing Weight = 449.9 1.50 674.6 Key Weight = Resisting/Overturning Ratio = 1.93 Vert. Component = 412.9 3.00 1,238.4 Vertical Loads used for Soil Pressure = 1,676.7 Ibs Total = 1,676.7 Ibs R.M.= 3,863.7 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Tor) of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.027 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R13/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall T to bottom of Ftg W/ slab Rebar Lap & Embedment Lengths Information Stem Design Segment: Bottom Stem Design Height: 0.00 ft above top of footing Lap Splice length for #4 bar specified in this stem design segment (25.4.2.4a) = 15.60 in Development length for #4 bar specified in this stem design segment = 12.00 in Hooked embedment length into footing for #4 bar specified in this stem design segment = 0.00 in As Provided = 0.3000 in2/ft As Required = 0.1424 in2/ft Kirkland, WA 98034 Project Title: R14/36 Engineer: Project ID: Project Descr: Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 pst.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 7' to bottom of Ftg W/ slab 4.. 6" w/ #4 @ 8" #4@8in @ Toe #4@8" @ Heel 3" 1.5" 6•-6„ Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R15/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 pst.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 7' to bottom of Ftg W/ slab Re: in Cn v v CR rn N 0') � M 858# ■ Lateral earth pressure due to the soil BELOW water table Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R16/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 9' to bottom of Ftg W/ Slab Code Reference: Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height - 8.00 ft Wall height above soil = 0.50 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 4.00 in Water table above bottom of footing = 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Soil Data Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 250.0 psf/ft Soil Density, Heel = 120.00 pcf Soil Density, Toe = 120.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem __ 0.0 psf (Service Level) Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall = 0.0 ft Poisson's Ratio = 0.400 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R17/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 9' to bottom of Ftg W/ Slab Design Summary Stem Construction Bottom Stem OK Design Height Above Ftg ft = 0.00 Wall Stability Ratios Wall Material Above "Ht" = Concrete Overturning = 1.81 OK Design Method = SD Slab Resists All Sliding ! Thickness = 8.00 Global Stability = 1.52 Rebar Size = # 5 Rebar Spacing = 12.00 Total Bearing Load = 2,418 Ibs Rebar Placed at = Edge ...resultant ecc. = 0.01 in Design Data Eccentricity within middle third fb/FB + fa/Fa = 0.540 Soil Pressure @ Toe = 435 psf OK Total Force @ Section Soil Pressure @ Heel = 434 psf OK Service Level Ibs = Allowable = 2,000 psf Strength Level Ibs= 1,120.0 Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 609 psf Service Level ft-#= ACI Factored @ Heel = 607 psf Strength Level ft-# = 2,986.7 Footing Shear @ Toe = 10.1 psi OK Moment..... Allowable = 5,527.6 Footing Shear @ Heel = 7.6 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = Sliding Calcs Strength Level psi = 15.1 Lateral Sliding Force = 1,417.5 Ibs Shear..... Allowable psi= 48.3 Anet (Masonry) in2 = Wall Weight psf= 100.0 Rebar Depth 'd' in = 6.19 Masonry Data Vertical component of active lateral soil pressure IS f'm psi = considered in the calculation of soil bearing pressures. Fs psi = Solid Grouting = Load Factors Modular Ratio 'n' _ Building Code Equiv. Solid Thick. _ Dead Load 1.000 Masonry Block Type = Live Load 1.000 Masonry Design Method = ASD Earth, H 1.000 Concrete Data Wind, W 1.000 f'c psi= 2,500.0 Seismic, E 1.000 Fy psi = 40,000.0 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R18/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 9' to bottom of Ftg W/ Slab Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) : 0.1696 in2/ft 0.0018bh : 0.0018(12)(8) : 0.1728 in2/ft Horizontal Reinforcing Options One layer of : Two layers of Required Area : 0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area : 0.31 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area : 1.2573 in2/ft #6@ 27.50 in #6@ 55.00 in Footing Data Footing Design Results Toe Width = 3.16 ft Toe Heel Heel Width = 0.83 Factored Pressure = 609 607 psf Total Footing Width = 3.99 Mu': Upward = 3,039 0 ft-# Footing Thickness = 12.00 in Mu': Downward = 949 129 ft-# Mu: Design = 2,091 OK 129 ft-# OK Key Width = 0.00 in phiMn = 7,853 8,783ft-# Key Depth = 0.00 in Actual 1-Way Shear = 10.06 7.61 psi Key Distance from Toe = 0.00 ft Allow 1-Way Shear = 75.00 75.00 psi f'c = 2,500 psi Fy = 40,000 psi Toe Reinforcing = # 5 @ 12.00 in Footing Concrete Density = 150.00 pcf Heel Reinforcing = # 5 @ 12.00 in Min. As % = 0.0018 Key Reinforcing = None Spec'd Cover @ Top 2.00 @ Btm = 3.00 in Footing Torsion, Tu = 0.00 ft-Ibs Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: #4@ 9.25 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.77 in, #8@ 36.57 in, #9@ 46.29 in, #10@ 58.79 in Heel: #4@ 9.25 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.77 in, #8@ 36.57 in, #9@ 46.29 in, #10@ 58.79 in Key: No key defined Min footing T&S reinf Area 1.03 in2 Min footing T&S reinf Area per foot 0.26 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R19/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 9' to bottom of Ftg W/ Slab Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Item Ibs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 1,417.5 3.00 4,252.5 Total = 1,417.5 O.T.M. = 4,252.5 Resisting/Overturning Ratio = 1.81 Vertical Loads used for Soil Pressure = 2,417.6 Ibs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. .....RESISTING..... Force Distance Moment Ibs ft ft-# Soil Over HL (ab. water tbl) 159.7 3.91 624.3 Soil Over HL (bel. water tbl) 3.91 624.3 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem = Soil Over Toe = 126.4 1.58 199.7 Surcharge Over Toe = Stem Weight(s) = 850.0 3.49 2,969.3 Earth @ Stem Transitions= Footing Weight = 599.0 2.00 1,195.8 Key Weight = Vert. Component = 682.6 3.99 2,725.6 Total = 2,417.6 Ibs R.M.= 7,714.8 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Tor) of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.026 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R20/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 9' to bottom of Ftg W/ Slab Rebar Lap & Embedment Lengths Information Stem Design Segment: Bottom Stem Design Height: 0.00 ft above top of footing Lap Splice length for #5 bar specified in this stem design segment (25.4.2.4a) = 15.60 in Development length for #5 bar specified in this stem design segment = 12.00 in Hooked embedment length into footing for #5 bar specified in this stem design segment = 0.00 in As Provided = 0.3100 in2/ft As Required = 0.2262 in2/ft Kirkland, WA 98034 Project Title: R21 /36 Engineer: Project ID: Project Descr: Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 pst.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 9' to bottom of Ftg W/ Slab @ Toe #5@ 12" @ Heel 3" 1.5" 8'-6„ Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. DESCRIPTION: L shape Ret wall 9' to bottom of Ftg W/ Slab Res 1418# R22/36 Printed: 14 MAY 2024, 5:03PM Project File: L-Shaped Retaining Wall 2000 psf.ec6 (c) ENERCALC INC 1983-2023 Cn 0 n - r` ti w L6 Cl) v � ■ Lateral earth pressure due to the soil BELOW water table Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R23/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 11' to bottom of Ftg W/ Slab Code Reference: Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height - 10.00 ft Wall height above soil = 0.50 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 4.00 in Water table above bottom of footing = 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf NOT Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 NOT Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Soil Data Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 250.0 psf/ft Soil Density, Heel = 120.00 pcf Soil Density, Toe = 120.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load ...Height to Top ...Height to Bottom Load Type 0.0 #/ft 0.00 ft 0.00 ft Wind (W) (Service Level) Wind on Exposed Stem __ 0.0 psf (Service Level) Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall = 0.0 ft Poisson's Ratio = 0.400 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R24/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 11' to bottom of Ftg W/ Slab Design Summary Stem Construction Bottom Stem OK Design Height Above Ftg ft = 0.00 Wall Stability Ratios Wall Material Above "Ht" = Concrete Overturning = 1.68 OK Design Method = SD Slab Resists All Sliding ! Thickness = 8.00 Global Stability = 1.18 Rebar Size = # 5 Rebar Spacing = 10.00 Total Bearing Load = 3,185 Ibs Rebar Placed at = Edge ...resultant ecc. = 0.91 in Design Data Eccentricity within middle third fb/FB + fa/Fa = 0.886 Soil Pressure @ Toe = 473 psf OK Total Force @ Section Soil Pressure @ Heel = 394 psf OK Service Level Ibs = Allowable = 2,000 psf Strength Level Ibs= 1,750.0 Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 662 psf Service Level ft-#= ACI Factored @ Heel = 552 psf Strength Level ft-# = 5,833.3 Footing Shear @ Toe = 14.7 psi OK Moment..... Allowable = 6,578.7 Footing Shear @ Heel = 10.9 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = Sliding Calcs Strength Level psi = 23.6 Lateral Sliding Force = 2,117.5 Ibs Shear..... Allowable psi= 51.3 Anet (Masonry) in2 = Wall Weight psf= 100.0 Rebar Depth 'd' in = 6.19 Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors Building Code Dead Load 1.000 Live Load 1.000 Earth, H 1.000 Wind, W 1.000 Seismic, E 1.000 Masonry Data f'm Fs Solid Grouting Modular Ratio 'n' Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data f'c Fy psi = psi = ASD psi = 2,500.0 psi = 40,000.0 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R25/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 11' to bottom of Ftg W/ Slab Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) : 0.3313 in2/ft 0.0018bh : 0.0018(12)(8) : 0.1728 in2/ft Horizontal Reinforcing Options One layer of : Two layers of Required Area : 0.3313 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area : 0.372 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area : 1.2573 in2/ft #6@ 27.50 in #6@ 55.00 in Footing Data Footing Design Results Toe Width = 4.16 ft Toe Heel Heel Width = 0.83 Factored Pressure = 662 552 psf Total Footing Width = 4.99 Mu': Upward = 5,465 0 ft-# Footing Thickness = 12.00 in Mu': Downward = 1,644 188 ft-# Mu: Design = 3,821 OK 188 ft-# OK Key Width = 0.00 in phiMn = 9,370 10,486ft-# Key Depth = 0.00 in Actual 1-Way Shear = 14.69 10.91 psi Key Distance from Toe = 0.00 ft Allow 1-Way Shear = 75.00 75.00 psi f'c = 2,500 psi Fy = 40,000 psi Toe Reinforcing = # 5 @ 10.00 in Footing Concrete Density = 150.00 pcf Heel Reinforcing = # 5 @ 10.00 in Min. As % = 0.0018 Key Reinforcing = None Spec'd Cover @ Top 2.00 @ Btm = 3.00 in Footing Torsion, Tu = 0.00 ft-Ibs Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: #4@ 9.25 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.77 in, #8@ 36.57 in, #9@ 46.29 in, #10@ 58.79 in Heel: #4@ 9.25 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.77 in, #8@ 36.57 in, #9@ 46.29 in, #10@ 58.79 in Key: No key defined Min footing T&S reinf Area 1.29 in2 Min footing T&S reinf Area per foot 0.26 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R26/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 1 V to bottom of Ftg W/ Slab Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Item Ibs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 2,117.5 3.67 7,764.2 Total = 2,117.5 O.T.M. = 7,764.2 Resisting/Overturning Ratio = 1.68 Vertical Loads used for Soil Pressure = 3,184.6 Ibs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. .....RESISTING..... Force Distance Moment Ibs ft ft-# Soil Over HL (ab. water tbl) 199.6 4.91 980.0 Soil Over HL (bel. water tbl) 4.91 980.0 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem = Soil Over Toe = 166.4 2.08 346.1 Surcharge Over Toe = Stem Weight(s) = 1,050.0 4.49 4,718.0 Earth @ Stem Transitions= Footing Weight = 749.0 2.50 1,869.8 Key Weight = Vert. Component = 1,019.7 4.99 5,091.2 Total = 3,184.6 Ibs R.M.= 13,005.1 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Tor) of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.028 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R27/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 1 V to bottom of Ftg W/ Slab Rebar Lap & Embedment Lengths Information Stem Design Segment: Bottom Stem Design Height: 0.00 ft above top of footing Lap Splice length for #5 bar specified in this stem design segment (25.4.2.4a) = 15.60 in Development length for #5 bar specified in this stem design segment = 12.00 in Hooked embedment length into footing for #5 bar specified in this stem design segment = 0.00 in As Provided = 0.3720 in2/ft As Required = 0.3713 in2/ft Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. DESCRIPTION: L shape Ret wall 1 V to bottom of Ftg W/ Slab 4" @ Toe #5@ 10" @ Heel R28/36 Printed: 14 MAY 2024, 5:03PM Project File: L-Shaped Retaining Wall 2000 psf.ec6 (c) ENERCALC INC 1983-2023 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. DESCRIPTION: L shape Ret wall 1 V to bottom of Ftg W/ Slab Res 2118# R29/36 Printed: 14 MAY 2024, 5:03PM Project File: L-Shaped Retaining Wall 2000 psf.ec6 (c) ENERCALC INC 1983-2023 M Cfl O Cl) M 0 Lateral earth pressure due to the soil BELOW water table Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R30/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 13' to bottom of Ftg W/ slab Code Reference: Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height - 12.00 ft Wall height above soil = 0.50 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 4.00 in Water table above bottom of footing = 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Soil Data Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 250.0 psf/ft Soil Density, Heel = 120.00 pcf Soil Density, Toe = 120.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem __ 0.0 psf (Service Level) Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall = 0.0 ft Poisson's Ratio = 0.400 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R31 /36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 13' to bottom of Ftg W/ slab Design Summary Stem Construction Bottom Stem OK Design Height Above Ftg ft = 0.00 Wall Stability Ratios Wall Material Above "Ht" = Concrete Overturning = 1.60 OK Design Method = SD Slab Resists All Sliding ! Thickness = 10.00 Global Stability = 124.67 Rebar Size = # 5 Rebar Spacing = 8.00 Total Bearing Load = 4,092 Ibs Rebar Placed at = Edge ...resultant ecc. = 1.51 in Design Data Eccentricity within middle third fb/FB + fa/Fa = 0.923 Soil Pressure @ Toe = 501 psf OK Total Force @ Section Soil Pressure @ Heel = 389 psf OK Service Level Ibs = Allowable = 2,000 psf Strength Level Ibs = 2,520.0 Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 702 psf Service Level ft-#= ACI Factored @ Heel = 545 psf Strength Level ft-# = 10,080.0 Footing Shear @ Toe = 19.8 psi OK Moment..... Allowable = 10,911.3 Footing Shear @ Heel = 0.0 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = Sliding Calcs Strength Level psi = 25.6 Lateral Sliding Force = 2,957.5 Ibs Shear..... Allowable psi = 50.4 Anet (Masonry) in2 = Wall Weight psf= 125.0 Rebar Depth 'd' in = 8.19 Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors Building Code Dead Load 1.000 Live Load 1.000 Earth, H 1.000 Wind, W 1.000 Seismic, E 1.000 Masonry Data f'm Fs Solid Grouting Modular Ratio 'n' Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data f'c Fy psi = psi = ASD psi = 2,500.0 psi = 40,000.0 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R32/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 13' to bottom of Ftg W/ slab Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) : 0.427 in2/ft 0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options One layer of : Two layers of Required Area : 0.427 in2/ft #4@ 10.00 in #4@ 20.00 in Provided Area : 0.465 in2/ft #5@ 15.50 in #5@ 31.00 in Maximum Area : 1.6637 in2/ft #6@ 22.00 in #6@ 44.00 in Footing Data Footing Design Results Toe Width = 5.16 ft Toe Heel Heel Width = 0.83 Factored Pressure = 702 545 psf Total Footing Width = 5.99 Mu': Upward = 8,741 0 ft-# Footing Thickness = 12.00 in Mu': Downward = 2,529 0 ft-# Mu: Design = 6,211 OK 0 ft-# OK Key Width = 0.00 in phiMn = 11,610 OK - Flush Key Depth = 0.00 in Actual 1-Way Shear = 19.79 0.00 psi Key Distance from Toe = 0.00 ft Allow 1-Way Shear = 75.00 0.00 psi f'c = 2,500 psi Fy = 40,000 psi Toe Reinforcing = # 5 @ 8.00 in Footing Concrete Density = 150.00 pcf Heel Reinforcing = Flush heel condition. No reinforcing required. Min. As % = 0.0018 Key Reinforcing = None Spec'd Cover @ Top 2.00 @ Btm = 3.00 in Footing Torsion, Tu = 0.00 ft-Ibs Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: #4@ 7.11 in, #5@ 11.02 in, #6@ 15.64 in, #7@ 21.33 in, #8@ 28.09 in, #9@ 35.56 in, #10@ 45.16 in Heel: Flush heel condition. No reinforcing required. Key: No key defined Min footing T&S reinf Area 1.55 in2 Min footing T&S reinf Area per foot 0.26 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R33/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 13' to bottom of Ftg W/ slab Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Item Ibs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 2,957.5 4.33 12,815.8 Total = 2,957.5 O.T.M. = 12,815.8 Resisting/Overturning Ratio = 1.60 Vertical Loads used for Soil Pressure = 4,092.1 Ibs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. .....RESISTING..... Force Distance Moment Ibs ft ft-# Soil Over HL (ab. water tbl) 0.0 5.99 0.0 Soil Over HL (bel. water tbl) 5.99 0.0 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem = Soil Over Toe = 206.4 2.58 532.5 Surcharge Over Toe = Stem Weight(s) = 1,562.5 5.58 8,713.5 Earth @ Stem Transitions= Footing Weight = 899.0 3.00 2,694.0 Key Weight = Vert. Component = 1,424.2 5.99 8,535.6 Total = 4,092.1 Ibs R.M.= 20,475.6 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Tor) of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.029 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: R34/36 Printed: 14 MAY 2024, 5:03PM Cantilevered Retaining Wall Project File: L-Shaped Retaining Wall 2000 psf.ec6 LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. (c) ENERCALC INC 1983-2023 DESCRIPTION: L shape Ret wall 13' to bottom of Ftg W/ slab Rebar Lap & Embedment Lengths Information Stem Design Segment: Bottom Stem Design Height: 0.00 ft above top of footing Lap Splice length for #5 bar specified in this stem design segment (25.4.2.4a) = 15.60 in Development length for #5 bar specified in this stem design segment = 12.00 in Hooked embedment length into footing for #5 bar specified in this stem design segment = 0.00 in As Provided = 0.4650 in2/ft As Required = 0.4913 in2/ft Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. DESCRIPTION: L shape Ret wall 13' to bottom of Ftg W/ slab R35/36 Printed: 14 MAY 2024, 5:03PM Project File: L-Shaped Retaining Wall 2000 psf.ec6 @ Toe 5'-2" 10" #5@6" 6'-0" @ Heel 3" (c) ENERCALC INC 1983-2023 Kirkland, WA 98034 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06015928, Build:20.23.08.30 RB Engineers, Inc. DESCRIPTION: L shape Ret wall 13' to bottom of Ftg W/ slab 2958# R36/36 Printed: 14 MAY 2024, 5:03PM Project File: L-Shaped Retaining Wall 2000 psf.ec6 (c) ENERCALC INC 1983-2023 C Q Q w CD M 0 Lateral earth pressure due to the soil BELOW water table