Loading...
FIR2022-0096 FIR WC3 APPROVED- Equip specsRECEIVED Sep 12 2022 FIR2022-0096 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SMITH FIRE SYSTEMS, INC. NC22102 ANTHOLOGY OF EDMONDS AUTOMATIC FIRE SPRINKLER SYSTEM EQUIPMENT SUBMITTAL 2120072 ND AVE WEST PLAN REVIEW ACCEPTANCE FOR COMPLIANCE WITH THE APPLICABLE CONSTRUCTION CODES IDENTIFIED BELOW. ❑ BUILDING [-]STRUCTURAL ❑ MECHANICAL ❑ PLUMBING ❑ ELECTRICAL [:]ENERGY ❑ ACCESSIBILITY ® FIRE PLAN REVIEW ACCEPTANCE OF DOCUMENTS DOES NOT AUTHORIZE CONSTRUCTION TO PROCEED IN VIOLATION OF ANY FEDERAL, CTATF nR I nCAL REGULATIONS. BY: _ " DATE:10/19/2022 WEST COAST CODE CONSULTANTS, INC. EDMONDS. WA SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East Tacoma, Washington 98424 (253) 926-1880 FAX (253) 926-2350 CONTR. REG. NO. SMITHFS1360T ANTHOLOGY OF EDMONDS 21200 72ND AVE WEST EDMONDS, WA. EQUIPMENT INDEX NO. MANUFACTURER SIZE MODEL DESCRIPTION 1 WILKINS 4" 350ASTDA 2 VICTAULIC 2999 4" 705 3 ALEUM 2999 6" DGC 4 RELIABLE 4" DDX-LP 5 POTTER ELECTRIC PS10-2A 6 POTTER ELECTRIC PS25-2A 7 RELIABLE --- A2 8 GAST 400 GAL. 5LCA-22- M550NGX 9 AGF 1.2599, 2" 1011 10 AGF 2.5" 8451A 11 ASHCROFT 1/4" 1005P XUL 12 WATTS 1" FBV 13 TYCO 1" DD-1 14 RELIABLE 12 HEAD A-4 15 RELIABLE 4.9K F1-RES 16 RELIABLE 5.6K F1 FR56 17 RELIABLE 5.6K F156 18 RELIABLE 5.6K DH56 19 RELIABLE 5.6K KFR 20 RELIABLE 5.6K F3QR N C22102 DOUBLE DETECTOR CHECK BACKFLOW ASSEMBLY BUTTERFLY VALVE SWING CHECK VALVE DRY PIPE VALVE ALARM PRESSURE SWITCH HIGH/LOW PRESSURE SWITCH AIR MAINTENANCE DEVICE AIR COMPRESSOR TEST AND DRAIN COMMERCIAL RISER PACK WATER GUAGE BALL VALVE DRUM DRIP SPARE HEAD BOX RESIDENTIAL SPRINKLERS QUICK RESPONSE SPRINKLERS STANDARD RESPONSE SPRINKLERS DRY SIDEWALL SPRINKLER CONCEALED SPACE SPRINKLER DRY SPRINKLERS Model 350ASTDA Double Check Detector Assembly Application Designed for installation on water lines in fire protection systems to protect against both backsiphonage and back - pressure of polluted water into the potable water supply. Model 350ASTDA shall provide protection where a potential health hazard does not exist. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance (Horizontal & Vertical) • ASSE® Listed 1048 • AWWA Compliant C510 (with gates only) and C550 • UL® Classified • C-UL® Classified • FM® Approved • CSA® Certified B64.5 • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California • Meets the requirements of NSF/ANSI 61" (0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT) By -Pass Backflow Assembly 3/4" Model 950XLD Materials Main valve body 304L Stainless steel Access covers 304L Stainless steel Internals Stainless steel, 300 Series NORYLTM Fasteners & springs Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM Features Sizes: 21/2", 3", 4", 6", 8", 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged) ANSI B16.1 Class 125 Dimensions & Weights (do not include pkg.) MODEL WEIGHT WITH WITH 350ASTDA WITH OS&Y WITH OS&Y BUTTERFLY BUTTERFLY SIZE GATES (GXF) GATES (GXG) VALVES (GXG) VALVES (FXG) in. I mm lbs. kg lbs. kg lbs. I kg lbs. I kg 21/2 65 126 57 116 53 93 42 103 47 3 80 143 65 131 60 97 44 110 50 4 100 218 99 198 90 101 46 123 56 6 150 352 160 322 147 164 74 194 88 8 200 667 303 613 278 350 159 373 169 10 250 1 885 401 827 375 463 210 521 236 ' HAD FREE Td %1 II~ 0. NSFIANSI 61 (SHOWN WITH OPTIONAL FLANGED END BUTTERFLY VALVES) Options (Suffixes can be combined) ❑ with flanged end OS & Y gate valves (standard) ❑ LM less water meter ❑ RM with remote reading meter ❑ with gallon meter (standard) ❑ CFM with cu ft meter ❑ CMM with cu meter meter ❑ G with grooved end OS&Y gate valves ❑ FG with flanged inlet gate connection and grooved outlet gate connection ❑ PI with Post Indicator Gate Valves ❑ BG with grooved end butterfly valves with integral supervisory switches ❑ BF with flanged end butterfly valves with integral supervisory switches ❑ —509 with AWWA C509 gate valves ❑ RV with By-pass on right hand side Accessories ❑ Repair kit (rubber only) ❑ Thermal expansion tank (Model XT) ❑ OS & Y Gate valve tamper switch (OSY-40) MODEL 350ASTDA with OS&Y option MODEL 350ASTDA with BF option c — D— MODEL DIMENSION (approximate) 350ASTDA A WITH B LESS E E E WITH SIZE A BUTTERFLY GATE C D OS&Y OS&Y BUTTERFLY F VALVES VALVES OPEN CLOSED VALVES in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm 2 1 /2 65 1 31 7/8 810 28 3/4 730 n/a n/a 12 305 7 1 /4 184 17 3/4 451 15 3/8 391 8 1 /4 210 5 127 3 80 32 7/8 835 29 3/8 746 n/a n/a 12 305 7 1 /4 184 20 1 /4 514 17 432 8 1 /4 210 5 127 4 100 34 7/8 886 30 1 /4 768 n/a n/a 12 305 8 203 22 1 /2 572 18 1 /4 464 9 229 5 127 6 150 43 1 /2 1 105 36 1 /2 927 n/a n/a 10 1 /2 267 10 254 30 1 /2 775 24 1 /4 616 10 1 /4 260 6 152 8 200 52 3/4 1340 45 3/4 1162 n/a n/a 15 1 /8 384 11 279 37 940 28 1 /2 724 18 1 /2 470 8 3/8 213 10 250 55 3/4 1416 49 3/4 1264 n/a n/a 15 1 /8 384 12 305 45 5/8 1159 34 3/4 883 18 1 /2 470 8 3/8 213 Zurn Industries, LLC I Wilkins Rev. N 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 Date: 12/19 Document No. BF-350ASTDA In Canada I Zurn Industries Limited Product No. Model 350ASTDA 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 www.zurn.com Page 1 of 2 Flow Characteristics 11 I► �----�--jam■ ORated Flow (established by approval agencies) 50.5 104 ro 4" (100mm) to 69 O J w K 35 U) Cl) w Ix a 0 0 200 400 600 FLOW RATES (GPM) MODEL350ASTDA6" 8" & 10" (STANDARDAND METRIC) FLOW RATES (1/s) 0.0 63.1 126.2 189.3 20 0 a 15 y cA " (150mm) 8" (200mm) 0 10 w y 5 w IL 0 — 0 1000 2000 3000 FLOW RATE (GPM) Typical Installation Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. ZURN WILKINS MODEL350ASTDABG INDOOR VERTICAL INSTALLATION 10" 800 252.4 138 m a Y 104 u) k 69 w 0 D m 35 w 0 0_ 0 4000 Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10ft/sec 15 ft/sec 21/2" 75 112 149 224 3" 115 173 230 346 4" 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 ZURN WILKINS MODEL 350ASTDA OUTDOOR HORIZONTAL INSTALLATION Specifications The Double Check Detector Backflow Prevention Assembly shall be certified to NSF/ANSI 61, ASSE® Listed 1048, and sup- plied with full port gate valves. The main body and access cover shall be 304L Stainless Steel, the seat ring and check valve shall be NoryIT"", the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detec- tor Backflow Prevention Assembly shall be a ZURN WILKINS Model 350ASTDA. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 www.zurn.com Page 2 of 2 Firel-ock® Butterfly Valve ✓ctaulIc® Series 705 with Weatherproof Actuator 10.81 Tfi 1.0 PRODUCT DESCRIPTION • Available Sizes: 2 — 12"/50 — 300 mm • cULus Listed, LPCB Listed, FM and VdS Approved for service up to 300 psi/2068 kPa 120 bar. • Designed for fire protection services only. • Features a weatherproof actuator housing Approved for indoor and outdoor use. • Actuation options: Hand wheel (2 — 12"/50 — 300 mm) • Exclusively for use with pipe and Victaulic products which feature ends formed with the Victaulic Original Groove System (OGS) groove profile (see section 7.0 for Reference Materials). 2.0 CERTIFICATION/LISTINGS C&S <FM Vd$ LPCB gP LISTED G410001 104j/04 NOTES • Refer to Victaulic submittal publication 10.01 for details ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Lpproved Date victaulic.com 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. 1 AtaulEcm virfnnlir rnm 2.1 CERTIFICATION/LISTINGS Approval/Listing Service Pressures Series 705 Butterfly Valve Size cULus FM Vds LPCB 2 50 up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa 21/2 65 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 3 80 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 4 100 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 5 125 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa 139.7 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 6 150 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 8 200 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10 250 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12 300 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 3.0 SPECIFICATIONS — MATERIAL Body: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 End Face, 2 — 6"/50 — 150 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Seal Retainer, 8 — 12"/200 — 300 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Body Coating: Black alkyd enamel Disc: Ductile Iron conforming to ASTM A-536, Grade 65-45-12, with electroless nickel coating conforming to ASTM B-733 Seat: Grade "E" EPDM Stems: 416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge: C36000 brass Bearings: Stainless steel with TFE lining Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: ❑ 2 — 8750 — 200 mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing ❑ 10 — 127250 — 300 mm: Steel worm and cast iron quadrant gear, in a cast iron housing 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 2 ✓ctaiuliic victaulic.com 4.0 DIMENSIONS Series 705 Size Dimensions Actual Outside E to E DIA Nominal Diameter A B C D E F G H J inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm 2 2.375 4.25 2.28 6.41 4.00 4.22 4.50 2.12 60.3 60.3 108.0 57.9 162.8 _ _ 101.6 107.2 114.3 53.8 21/2 2.875 3.77 2.28 7.54 4.00 4.22 4.50 1.77 73 73.0 95.8 57.9 191.5 _ _ 101.6 107.2 114.3 45.0 76.1 mm 3.000 3.77 2.28 7.54 _ _ 4.00 4.22 4.50 1.77 76.1 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3 3.500 3.77 2.53 7.79 4.50 4.22 4.50 1.77 88.9 88.9 95.8 64.3 197.9 _ _ 114.3 107.2 114.3 45.0 108mm 4.250 4.63 2.88 8.81 _ _ 5.50 4.22 4.50 2.20 108.0 117.6 73.2 223.8 139.7 107.2 114.3 55.9 4 4.500 4.63 2.88 8.81 5.50 4.22 4.50 2.20 114.3 114.3 117.6 73.2 223.8 _ _ 139.7 107.2 114.3 55.9 133 mm 5.250 5.88 3.35 10.88 _ _ 6.56 6.19 6.30 2.58 133.0 149.4 85.1 276.4 166.6 157.2 160.0 65.5 139.7mm 5.500 5.88 3.35 10.88 _ _ 6.56 6.19 6.30 2.58 139.7 149.4 85.1 276.4 166.6 157.2 160.0 65.6 5 5.563 5.88 3.35 10.88 6.56 6.19 6.30 2.58 141.3 141.3 149.4 85.1 276.4 _ _ 166.6 157.2 160.0 65.5 159mm 6.250 5.88 3.84 11.38 _ 0.41 7.52 6.19 6.30 2.58 159.0 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 165.1 mm 6.500 5.88 3.84 11.38 _ 0.41 7.52 6.19 6.30 2.58 165.1 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 6 6.625 5.88 3.84 11.38 0.41 7.52 6.19 6.30 1.90 168.3 168.3 149.4 97.5 289.1 _ 10.4 191.0 157.2 160.0 48.3 8 8.625 5.33 5.07 13.53 0.80 1.47 10.00 6.19 8.10 2.33 219.1 219.1 135.4 128.8 343.6 20.3 37.3 254.0 157.2 205.7 59.2 10 10.750 6.40 6.37 15.64 1.41 1.81 12.25 8.10 9.00 273 273.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 228.6 _ 12 12.750 6.50 7.36 16.64 2.30 2.80 14.25 8.10 9.00 323.9 323.9 165.1 186.9 422.7 58A 71.1 362.0 205.7 228.6 _ NOTE • Optional 'h"/15 mm tap available. Contact Victaulic for details. 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com ✓ctaulim victaulic.com 5.0 PERFORMANCE Series 705 The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/meters of straight pipe. Nominal Outside Equivalent Size Diameter mm mm Feet/m inches inches of pipe 2 2.375 6 50 60.3 1.8 6 21/2 2.875 65 73.0 1.8 76.1 mm 3.000 6 76.1 1.8 3 3.500 7 80 88.9 2.1 4 4.500 8 100 114.3 2.4 108 mm 108 mm 8 2.4 5 5.563 12 125 141.3 3.7 133 mm 133 mm 12 3.7 139.7 mm 5.500 12 139.7 3.7 6 6.625 14 150 168.3 4.2 159 mm 159 mm 14 4.3 165.1 mm 6.500 14 165.1 4.2 8 8.625 16 200 219.1 4.9 10 10.750 18 250 273.0 5.5 12 12.750 19 300 323.9 5.8 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com M ✓ctaUIiCr victaulic.com 5.1 PERFORMANCE Series 705 Cv values for flow of water at +600F/+16°C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for Cv values Formulas for Kv values AP = Q2 Where: AP = Q2 C 2 Q= Flow (GPM) K 2 AP = Pressure Drop (psi) Q = Cv x AP Cv = Flow Coefficient Q = K x AP Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches C mm mm 2 2.375 170 50 60.3 21/2 2.875 260 65 73.0 76.1 mm 3.000 260 76.1 3 3.500 440 80 88.9 4 4.500 820 100 114.3 108mm 108mm 820 5 5.563 1200 125 141.3 133 mm 133 mm 1200 139.7mm 5.500 1200 139.7 6 6.625 1800 150 168.3 159 mm 159 mm 1800 165.1 mm 6.500 1800 165.1 8 8.625 3400 200 219.1 10 10.750 5800 250 273.0 12 12.750 9000 300 323.9 Where: Q = Flow W/hr) AP = Pressure Drop (Bar) K = Flow Coefficient Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches K mm mm 2 2.375 147 50 60.3 21/2 2.875 225 65 73.0 76.1 mm 3.000 225 76.1 3 3.500 380 80 88.9 4 4.500 710 100 114.3 108mm 108mm 710 5 5.563 1040 125 141.3 133 mm 133 mm 1040 139.7 mm 5.500 1040 139.7 6 6.625 1560 150 168.3 159 mm 159 mm 1560 165.1 mm 6.500 1560 165.1 8 8.625 2940 200 219.1 10 10.750 5020 250 273.0 12 12.750 300 323.9 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 5 ✓ctaulir virfnnlir rnm 6.0 NOTIFICATIONS A WARNING • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Switch and Wiring 1. The supervisory switch contains two single pole, double throw, pre -wired switches. 2. Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC 3. Switches supervise the valve in the "OPEN" position. 5. One switch has two #18 insulated wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 insulated wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. 6. A #14 insulated ground lead (green) is provided. Switch #1 = S1 For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction S1 Normally Closed: (2) Blue Common: (2) Yellow S2 fNormally Closed: Blue with Orange Stripe Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe UL LISTED JUNCTION BOX CONDUIT h'NPT CONDUIT CONNECTORS P WIRE NUTS FIRE ALARM TO END -OF -LINE RESISTOR, CONTROL PANEL OR NEXT INDICATOR SUPERVISORY CIRCUIT i,l:; NO. COM. SWITCH CONTACT RATING: 10A AT 125 AND ■ S1 250VAC, O.SA AT 125 VDC, 0.25 AT 250 VDC ■ ■ 52 BELL OR VOLTAGE SOURCE HORN Switch 1:2leads per termina Switch 2:1 lead per terminal NOTES • The above diagram shows a connection between the common terminal (yellow — S1 and yellow -with -orange stripe — S2) and the normally closed terminal (blue — S1 and blue -with -orange stripe — S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e.g. brown with orange stripe). • Only S1 (two leads per terminal) may be connected to the fire alarm control panel. • The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 0 ✓ctaulir victaulic.com 7.1 REFERENCE MATERIALS 10.01: Regulatory Approval Reference Guide 29.01: Terms and Conditions/Warranty 1-100: Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end -use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 7 ✓ctaulim Section 4.0 1 Check Valves DGC Swing Check Valve Grooved Technical Features • Connections: Grooved Ends (AWWA C606) • Sizes: 2", 2-1/2", 3", 4", 5", 6", 8", 10", 12" 1265 N. Grove St. Anaheim • CA 92806 • United States T:714-520-0338 F:714-520-0335 E: aleum@aleumusa.com www.aleumUSA.com ALEUM c&S <FM> LISTED APPROVED • Approvals: UL, ULC, and FM • Maximum Working Pressure: 30OPSI (Max. Test Pressure: 600PS1) • Maximum Working Temperature: 250OF (1201C) • Application: Indoor and Outdoor Use • Low pressure -drop, Non -slam performance Parts Components Material Specification 1 Body Ductile Iron,Epoxy Coated A536 65-45-12 2 Clapper Stainless Steel ANSI 304 3 Coil Spring Stainless Steel ANSI 302 4 Nut Stainless Steel ANSI 304 5 Bolt Stainless Steel ANSI 304 6 Washer Stainless Steel ANSI 304 7 Facing Seal Rubber EPDM 8 Seat Ring Stainless Steel ANSI 304 9 Drain Plug Ductile Iron Drain Plug 10 Pin Plug Ductile Iron Pin Plug 11 Bushing AluminumBronze Bushing 12 Hinge Pin Stainless Steel Hinge Pin 13 Hook Steel Hook 14 Oil Ring EPDM 15 Waser ASTM A-307 Dimensions Size Dl D2 D3 L Ll L2 in mm in mm in mm in mm in mm in mm 2" 1.9 49.0 2.2 57.1 2.4 60.3 6.7 170.0 0.6 15.8 0.3 8.7 2-1/2" 2.4 62.2 2.7 69.0 2.9 73.0 7.2 184.0 0.6 15.8 0.3 8.7 3" 2.9 74.0 3.3 84.7 3.5 89.1 7.6 195.0 0.6 15.8 0.3 8.7 4" 3.9 98.0 4.3 109.8 4.5 114.3 8.1 205.0 0.6 15.8 0.3 8.7 5" 5.4 137.0 5.6 141.3 9.8 247.7 0.6 15.8 0.3 8.7 6" 6.1 156.0 6.4 163.7 6.6 168.3 12.6 320.0 0.6 15.8 0.3 8.7 8" 7.9 201.6 8.5 215.8 8.6 218.2 14.6 372.0 0.8 20.1 0.4 10.5 10" 10.6 268.3 10.7 273.0 18.0 457.2 0.8 20.1 0.5 12.7 12" 12.5 318.3 12.8 323.9 21.1 534.9 0.8 20.1 0.5 12.7 21 Bulletin 337 Model DDX-LPCU Dry Pipe Valve System w 2" (50 mil 2'/2" (65 mil 3" (80 mil 76 mm, 4" (100 mil 6" (150 mm),165 mm & 8" (200mm) Features 1. Differential latching clapper -type, lightweight, dependable construc- tion. 2. Low Air Pressurized System, 8 psi -to- 28 psi (0,6 bar -to- 1,9 bar) 3. Reset externally. Cover removal is not required. 4. No priming water requirement 5. Hydrostatic testing with the clapper in the closed position 6. No riser check valve required 7. One Main Drain 8. Drain valve to drain standing water column. 9. Valve latches in open position. No pressure -operated relief valve is re- quired. 10. Nitrogen pressurized system op- tional 11. Grooved or Flanged End Connec- tions. 12. Pressure rating of 250 psi (17,2 bar) or 300 psi (20,7 bar). Listings & Approvals (Only when used with Reliable's Trim Sets.) 1. Listed by Underwriters Laboratories, Inc. and UL certified for Canada (cULus). 2. Certified by Factory Mutual Approvals (FM). 3. NYC MEA 258-93-E 4. LPCB (4" (100MM), 165MM, 6" (150MM) and 8" (200MM) Only) 5. CE 6. VdS SchadenverhOtung GmbH The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 N DDX VALVE CLAPPER IN "OPEN", "CLOSED" REAR VIEW OF MODEL AND "LATCHED" POSITIONS DDX VAL VE TO SYSTEM 4 CLAPPER IN LEVER O OPEN" POSITION PUSH ROD PUSH ROD CHAMBER CLAPPER IN OUTLET "LATCHED" POSITION o ` CLAPPER IN "CLOSED" POSITION PUSH ROD i PUSH ROD CHAMBER INLET ALARM PORT O CHAMBER RESTRICTION TEST PORT DDX EXTERNAL EXTERNAL RESET KNOB RESET KNOB DRAIN PORT 4 FROM 37FGOI SUPPLY PUSH INWARD AND ROTATE KNOB CLOCKWISE TO RESET CLAPPER. DO SO ONLY WHEN PUSH ROD CHAMBER IS VENTED. Fig. 1 General The Reliable Model DDX-LP Dry Pipe Valve is a hydrau- lically operated, differential latching clapper -type valve (see Fig 1.) designed for use as a primary control valve in a low pressure dry pipe valve system. The trim set used with the Model DDX-LP Dry Pipe Valve contains the Reli- able Model LP Dry Valve Actuator releasing device. This Actuator allows the system's air or nitrogen pressure re- quirement to be considerably less than the available water supply pressure (see Table A). The following benefits are a direct result of lower air pressure: 1 In refrigerated area systems, lower air pressure de- creases the possibility of ice plugs, which could im- pede or prevent the flow of water to sprinkler heads in the event of fire. 2 Lower air pressure (volume) will enable smaller ca- pacity, lower cost dehydration equipment when it is required. 3 Lower air or nitrogen pressure can reduce water deliv- ery time when the system actuates, and in some cases, may eliminate the need for an accelerator. 4 Low pressure requirements make the use of dry nitro- gen gas, instead of air, practical even on larger sys- tems. Resulting benefits include a lower -than -air dew point, which minimizes ice plugging of system lines, and enhances "user friendliness" during installation and operation. 5 System maintenance is simplified since priming water is not required and the Dry Pipe Valve can be reset externally without cover removal. This is accomplished by pushing in and turning the external reset knob at the rear of the Dry Pipe Valve (see Fig. 1). This feature pro- vides a significant system -restoration time advantage. The Model DDX-LP Dry Pipe Valve's trim set (see Fig.2) provides all of the necessary equipment for connections to the pushrod chamber's inlet and outlet ports, the 11/4" (30mm) or 2" (50mm) main drain, alarm devices, air sup- ply, water supply and required pressure gauges. This trim set is available in individual parts, in time -saving, segmen- tally assembled kit forms, or fully assembled to the Model DDX-LP Dry Pipe Valve (with or without a control valve). All the sizes of the Model DDX-LP Dry Pipe Valve trim sets may be equipped with the optional Reliable Model B1 Accelerator, trim kit P/N 6516000003, (see Figs. 2 & 3). This device acts as an exhauster which will hasten the op- eration of the Model LDX Dry Valve Actuator and minimize the water delivery time for the entire system. System Operation The Reliable Model DDX-LP Dry Pipe Valve is shown in both closed and open positions in Fig. 1. In the closed position, the supply pressure acts on the underside of the clapper and also on the push rod through the push rod chamber's inlet restriction. The resultant force due to the supply pressure acting on the push rod is multiplied by the mechanical advantage of the lever and is more than sufficient to hold the clapper closed against normal supply pressure surges. When a sprinkler operates, there will be a loss of air or nitrogen pressure in the sprinkler system's piping which will cause the Model LP Dry Valve Actuator to open. The opening of this device allows a releasing discharge of wa- ter from the pushrod chamber's outlet connection. Since the pressure cannot be replenished through the inlet re- striction as rapidly as it is vented, the push rod chamber pressure falls instantaneously. When the push rod cham- ber pressure approaches approximately one-third of the supply pressure, the upward force of the supply pressure acting beneath the clapper overcomes the lever -applied force thereby opening the clapper. Once the clapper has opened, the lever acts as a latch, preventing the clapper from returning to the closed po- sition. Water from the supply flows through the Dry Pipe Valve into the system piping. Water also flows through the Dry Pipe Valve's alarm outlet to the alarm devices. After system shutdown, resetting the Model DDX-LP Dry Pipe Valve is quite simple. Doing so only requires push- ing in and turning the reset knob at the rear of the valve (see Fig. 1). The external reset feature of the Model DDX- LP Dry Pipe Valve provides a means for simple, economi- cal system testing, which is one essential facet of a good maintenance program. The external reset feature does not, however, eliminate another important facet of good maintenance, namely, periodic cleaning and inspection of the internal valve parts. In the event that water builds up inside the valve due to condensate from the air supply system or water left inside from valve system testing, a drain is available for venting. After closing the main supply valve, a small valve over the drain cup can be opened slightly until the water inside the valve body and the main pipe column has drained. The Model B Manual Emergency Station is also included in the Model DDX-LP Dry Pipe Valve trim set. It consists of an aluminum nameplate mechanically attached to a ball valve. The valve handle in its OFF position is guarded against accidental turning to the ON position (and system discharge) by a nylon cable tie provided with each trim kit. The cable tie is inserted after the system has been re- stored for operation. The nylon cable tie is designed to al- low, in case of an emergency, forceful turning of the valve handle to the ON position. As an alternative to the Model B Hydraulic Manual Emergency Station, the Model A Hy- draulic Manual Emergency Pull Box (see Reliable Bulletin 506) is also available and can be provided as an option. Whenever ambient temperature conditions are high, the water temperature in the Model DDX-LP Dry Pipe Valve's pushrod chamber could possibly increase, thereby in- creasing the pressure in the chamber to values exceed- ing the rated pressure of the system. In an indoor installa- tion where standard room temperatures are exceeded, a pressure relief kit may be needed. Pressure relief kit, P/N 6503050001, can be installed into the pushrod chamber's releasing line to limit the pressure to 250 psi (17,2 bar). 3. Hydrostatic Testing of DDX Valves and DDX Systems As required by NFPA 13, fire sprinkler systems with working pressures up to and including 150 psi are to be hydrostatically tested at a water pressure of 200 psi and maintain that pressure without loss for two hours. Fire sprinkler systems with working pressures above 150 psi are required to be hydrostatically tested at 50 psi above the system working pressure and maintain that pressure without loss for two hours. In addition to the hydrostatic tests described above, dry pipe and double interlock pre - action systems require an additional low pressure air test. In some cases, hydrostatic testing (in accordance with the NFPA 13 requirements noted above) will result in pres- sures that exceed the working Pressure of the valve and trim kit for the two-hour test period. The valve and appli- cable trim kit have been tested, approved and listed under these conditions and as such, hydrostatic testing in accor- dance with NFPA 13 is acceptable. In addition, the clap- per can remain in the closed position and the trim kit need not be isolated, as each has been designed to withstand hydrostatic testing as required by NFPA 13. Hydrostatically testing the valve and trim to pres- sures higher than their rating is limited to the hydrostatic test as referenced by NFPA13. It does not address the occurrence(s) of a "water hammer" effect, which can in- deed damage the valve. A "water hammer" in the water supply piping of the valve can create pressures in excess of the rated pressure and should be avoided by all neces- sary means. This condition may be created from improper fire pump settings, underground construction work, or an improper venting of trapped air in the water supply piping_ Technical Data Reliable Model DDX-LP Dry Pipe Valves, with associated trim, sizes 2" (50mm), 21/2" (65mm), 76mm, 3" (80mm), 4" (100mm), 165mm, 6" (150mm) and 8" (200mm) are rated for use at a minimum water supply pressure of 20 psi (1,4 bar) and a maximum water supply pressure of 250 psi (17,2 bar) for 2" (50mm), 21/2" (65mm), 3" (80mm), 76mm and 8" valve sizes and 300 psi (20,7 bar for 4" (100mm), 6" (150mm) and 165mm valve sizes. Water supplied to the inlet of the valve and to the pushrod chamber must be maintained between 40°F (4°C) and 140°F (60°C). The following list of technical bulletins pertains to valves and devices that may be used in this Dry Pipe Valve sys- tem: Deluge/Dry Pipe Valve Reliable 518/519 Mechanical Sprinkler Alarm Reliable 612/613 Pressure Maintenance Device Reliable 254 Nitrogen Regulating Device Reliable 254 Model 131 Accelerator Trim Kit Reliable 323 Hydraulic Emergency Station (Model A) Reliable 506 Low Air Pressure Alarm Switch System Sensor A05-0177 Waterflow Pressure Alarm Switch System Sensor A05-0176 Model DDX-LP Dry Pipe Valve Description 1 Rated working pressure: Valve & System - 250 psi (17.2 bar) for 2" (50mm), 21/2" (65mm), 3" (80mm), 76mm and 8" (200mm) valve sizes or 300 psi (20,7 bar) for 4" (100mm), 6" (150mm) and 165mm valve sizes). 2 Factory tested to a hydrostatic pressure of 500 psi (34,5 bar) for 2" (50mm), 21/2" (65mm), 3" (80mm), 76mm and 8" (200mm) valve sizes or 600 psi (41,4 bar) for 4" (100mm), 6" (150mm) and 165mm valve sizes). (Valve only) 3 End and trim connections: • ANSI/AWWA C606 grooved inlet and outlet Nominal Outlet Groove Groove Outlet Pipe Size Diameter Diameter Width Face to Groove 2" (50 mm) 2.375" 2.250" 11/32" 5/8" 60mm) (57mm) (9.Omm) (16mm 21/2" (65 mm) 2.875" 2.720" 11/32" 5/8" (73mm) I (69mm) (9.Omm) (16mm) 76 mm 3.0001, 2.845" 11/32" 5/8" (76mm) (72mm) (9.Omm) (16mm) 3" (80 mm) 3.500" 3.344" 11/32" 5/8" (89mm) (85mm) (9.Omm) (16mm) 4" (100 mm) 4.500" 4.334" 3/8" 5/8" (114mm) (110mm) (9.5mm) (16mm) 165 mm 6.500" 6.330" 3/8" 5/8" (165mm) (161mm) (9.5mm) (16mm) 6" (150 mm) 6.625" 6.455" 3/8" 5/8" (168mm) (164mm) (9.5mm) (16mm) 8" (200 mm) 8.625" 8.441" 7/16" 3/4" (219mm) (214mm) (11mm) (19mm) Threaded openings Per ANSI B 2.1 Flange Dimensions: Range Nominal Bolt Bolt Flange Number Tom' Pipe larde Hole Outside m kkness of She Diamder Diameter Diameter Bolls ANISEB16.5 4' 7'/Y 3/a' 9' 15/s' 8 Class 150 (100mm) (191mm) (19rm) (229mm) (24mm) IS07005-2 4' 73/� 3/a' 9 15�6' 8 PN16 (100rrm) (18Omm) (19mm) (229mm) (24mm) AIVISEB16.5 6' 91/Y 8" 11" 15/s' 8 Class 150 (15Omm) (241mm) (22rrn) (279mm) (24mm) ISO7005-2 6' 9'/s' / ' 11" 15�s 8 PN16 (150mm) (240rrm) (23mm) (279mm) (24mm) ANISEB16.5 9' 113/d' 7/11 13/z' 1" 8 Class 150 (200mm) (29&rm) (227m) (343rrm) (25.4mm) IS0 7005-2 9' 115 8" 32' 131/z' ill 12 PN16 (200irm) (295mm) (23rm) (343mm) (25.4mm) 4 Valve Exterior's Color: Valve Size Color 2" (50 mm) Black or Red 21/2" (65 mm) Black or Red 76 mm Red 3" (80 mm) Black or Red 4" (100 mm) Black or Red 165 mm Red 6" (150 mm) Black or Red 8" (200 mm) Black or Red 0 FROM AIR OR NITROGEN SUPPLY PRESSURE RELIEF VALVE AIR SIDE MODEL LP DRY VALVE ACTUATOR PUSH —ROD CHAMBER WATER TO p PRESSURE GAUGE SIDE p DRIP VI CUP VENT TO ATMOSPHERE OPTIONAL MODEL Bi ACCELERATOR KIT Rr (PART NUMBER 6516000003) TO — — TO SYSTEM ALARM PRESSURE TO TO C� SWITCH DRIP TO DRAIN TO CUP DRIP NON—SILENCEABLE MODEL DDX-LP DRY PIPE VALVE GDP ALARM PRESSURE SWITCH (REF. NFPA,j72) TO y� MECHANICAL SPRINKLER ° ALARMBAR PUSH ROD CHAMBER Z°psi SUPPLY LINE VA, TUBING Fig. 2 5. 337FGO2 UIRE PT )RY RELIABLE MODEL B 1 ACCELERATOR KIT (P/N 651 6000003 AIR PRESSURE GAUC MODEL B 1 ACCELERATOR NIPPLE, 112" x 2" ELBOW, 112 NOTE: A MINIMUM OF 15 PSI (1,0 BAR) OF SUPERVISORY AIR PRESSURE IS REQUIRED WHEN USING A MODEL B 1 ACCELERATOR. 1 VENT TO ATMOSPHERE NIPPLE, 112" x 2" MODEL DDX-LP Y PIPE VALVE ;YSTEM TRIM NIPPLE, 112" x 3" ?ALL VALVE, 112" SEE BULLETIN 323 FOR DETAILS 337FG03 Fig. 3 MODEL B HYDRAULIC MANUAL EMERGENCY STATION �F �E lqO NYLON TIE STq�wp PLASTIC TUBING 519FG09 TO DRIP CUP Fig. 4 i* 5 Face to face dimensions: Valve Size: End Connection: End to End: 2" (50mm), 21/2" (65mm), 76mm & 3" (80mm) Groove/ Groove 121/2" (318mm) 4" (100mm) Groove/ Groove 14" (356mm) Flange/ Groove 16" (406mm) Flange/ Flange 16" (406mm) 6" (150mm) & 165mm Groove/ Groove 16" (406mm) Flange/ Groove 19" (483mm) Flange/ Flange 19" (483mm) 8" (200mm) Groove/ Groove 193/ " (492mm) Flange/ Flange 211/4" (540mm) 6 Valve Shipping Weight: Valve Size: End Connection: Weight: 2" (50mm), 21/2" (65mm), 76mm & 3" (80mm) Groove/ Groove 34 Ibs (15 kg) 4" (100mm) Groove/ Groove 64 Ibs (29 kg Flange/ Groove 79 Ibs (36 kg) Flange/ Flange 92 Ibs (42 kg) 6" (150mm) & 165mm Groove/ Groove 95 Ibs (43 kg) Flange/ Groove 122 Ibs (56 kg)_ Flange/ Flange 138 Ibs (69 kg) 8" (200mm) Groove/ Groove 148 Ibs (67 kg) Flange/ Flange 197 Ibs (90 kg) 7 Trim Shipping Weight: 2" (50 mm), 4" (100 mm), Trim Configuration 2112" (65 mm), 6" (150 mm), 3" (80 mm) 8" (200 mm) &76mm &165mm Model DDX LP Low Pressure Dry Pipe 46lbs 53lbs Valve (20.9 kg) (24 kg) 8 Friction loss (Expressed in equivalent length of Sched- ule 40 pipe, based on Hazen & Williams formula: Valve Size: Cv C 0Length:CE 12valent 2" 50mm 4.4 ft 1,3 m 3.1 ft 1,0 m 101 21/2" 65mm) 6.0 ft (1,8 m) 4.3 ft (1,3 m) 236 76mm 7.7 ft 2,3 m 5.5 ft 1,7 m 241 3" 80mm 12.6 ft 3,8 m 9.0 ft 2,7 m 254 4" (100mm) 14 ft (4,3 m) 10 ft (3,0 m) 469 165mm 29.4 ft 9,0 m 20.9 ft 6,4 m 886 6" 150mm 29.4 ft 9,0 m 20.9 ft 6,4 m 886 8" 200mm 53.5 ft 16,3 m 38.1 ft 11,6 m 1516 9 Installation position: Vertical System Air or Nitrogen Pressure Requirements The system trim includes gauges to read the pneumat- ic and water pressures of Model LP Dry Valve Actuator. Table A specifies the air or nitrogen pressure level to be applied to the Actuator. Optional Reliable Model A-2 Pres- sure Maintenance Device (see Reliable Bulletins 254) au- tomatically provides a safeguard against pressure leaks in the sprinkler piping, and properly restricts the flow of makeup air. When the optional Model 131 Accelerator is used, a Model A-2 Pressure Maintenance Device and a tank -mounted air compressor are required. Also, when a Model 131 Accelerator is used, to expedite water -delivery time, the pneumatic pressure must not be less than 15 psi (1,0 bar). Whenever multiple dry systems are installed at the same location, each dry system is to have its own Model A-2 Pressure Maintenance Device installed for individual maintenance of air pressure (Refer to the 2007 Edition of NFPA 13, section 7.2.6.5.3). Table A Water Pressure psi bar Pneumatic Pressure to be Pumped into Sprinkler System psi bar Maximum Not Less Than Not More Than 20(1.4) 8(0.6) 10(0.7) 30(2.1) 10(0.7) 14(1.0) 50(3.4) 12(0.8) 16(1.1) 75(5.2) 13(0.9) 17(1.2) 100 (6.9) 15(1.0) 19(1.3) 125(8.6) 16(1.1) 20(1.4) 150 (10.3) 17(1.2) 21(1.4) 175 (12.1) 18(1.2) 22(1.5) 200 (13.8) 19(1.3) 23(1.6) 225 (15.5) 21(1.4) 25(1.7) 250 (17.2) 22(1.5) 26(1.8) 275 (19.0) 23(1.6) 27(1.9) 300 (20.7) 24(1.7) 28(1.9) Note: During system set-up, a higher pneumatic pres- sure may be required in order to properly set the Model LP Dry Valve Actuator. Nitrogen used in refrigerated area systems minimizes a possibility of ice build-up and blockage inside the system piping that could inhibit proper system operation. The cal- culated nitrogen supply in Ibs (kg) to pressurize various system capacities to 10 psi (0,7 bar) at different freezer temperatures is as follows: System Freezer Temperature, °F (°C) Approx. Capacity 20 0 -20 -40 -60 Fill Time Gal. (L) (-6.7) (-18) (-29) (40) (-51) (min*) 250 1.90 1.90 2.00 2.10 2.20 1 (946) (0.86) (0.86) (0.91) (0.95) (1.00) 500 3.64 2.80 4.00 4.20 4.40 2 (1893) (1.65) (1.27) (1.81) (1.91) (2.00) 750 5.50 5.70 6.00 6.30 6.60 3 (2839) (2.49) (2.59) (2.72) (2.86) (2.99) 1000 7.30 7.60 8.00 8.33 8.80 4 (3785) (3.31) (3.45) (3.63) (3.78) (3.99) Note: (1 bar =100 kPa) Consult Reliable Bulletin 338 for more detailed information. * When filled with the Reliable Model A-2 Pressure Maintenance Device having the bypass valve open Patents U.S. Patent Number 6,068,057 for a Dry Pipe Valve Arrangement 7. Ordering Information Specify: • Valve Model & Size Valve Part Numbers Valve Size & End Connection Flange Type Color Reliable Part Number 2" (50mm) Grv/Gry N/A Black 6103022000 Red 6103022001 21/2" (65mm) Grv/Gry N/A Black 6103022500 Red 6103022501 3" (80mm) Grv/Gry N/A Black 6103030000 Red 6103030001 76mm Grv/Gry N/A Red 6103027600 4" (100mm) Grv/Gry N/A Black 6103040026 Red 6103040030 4" (100mm) Flg/Gry ASME Class 150 Black 6103040044 ASME Class 150 Red 6103040046 ISO PN16 Red 6103040048 4" (100mm) Flg/Flg ASME Class 150 Black 6103040045 ASME Class 150 Red 6103040047 ISO PN16 Red 6103040049 6" (168mm) Grv/Gry N/A Black 6103060024 Red 6103060030 6" (168mm) Flg/Gry ASME Class 150 Black 6103060045 ASME Class 150 Red 6103060047 ISO PN16 Red 6103060049 6" (168mm) Flg/Flg ASME Class 150 Black 6103060046 ASME Class 150 Red 6103060048 ISO PN16 Red 6103060050 165mm Grv/Gry N/A Red 6103060028 165mm Flg/Gry ASME Class 150 Red 6103060051 ISO PN16 Red 6103060052 8" (200mm) Grv/Gry N/A Black 6103080001 Red 6103080003 8" (200mm) Flg/Flg ASME Class 150 Black 6103080016 ASME Class 150 Red 6103080018 ISO PN16 Red 6103080020 0 Trim — The trim set is available in individual parts, in time -saving segmentally assembled kit forms, or fully as- sembled to the Model DDX-LP Dry Pipe Valve (with or without a control valve). Trim Part Numbers Trim Configurations Valve Size &End Connection Flange g Type Color Individual Parts ( Model DDX Valve Sold Seperately) Segmentally Assembled (Model DDX Valve Sold Valve old S SeperBlack Full Assembled y to Model DDX Valve w/o Control Valve Full Assembled y to Model DDX Valve w/ Control Valve 2" (50mm) Grv/Gry N/A 6505040503 6505040504 6505020021 6505020020 Red 6505A20021 6505A20020 21/2" (65mm) Grv/Gry N/A Black 6505022521 6505022520 Red 6505A22521 6505A22520 3" (80mm) Grv/Gry N/A Black 6505030021 6505030020 Red 6505A30021 6505A30020 76mm Grv/Gry N/A Red 6505A27621 N/A 4" (100mm) Grv/Gry N/A Black 6505041002 6505041003 6505040221 6505040220 Red 6505A40221 6505A40220 4" (100mm) Flg/Gry ASME Class 150 Black 6505043221 N/A ASME Class 150 Red 6505A43221 ISO PN16 Red 6505A44221 4" (100mm) Flg/Flg ASME Class 150 Black 6505047221 N/A ASME Class 150 Red 6505A47221 ISO PN16 Red 6505A48221 6" (168mm) Grv/Gry N/A Black 6505060221 6505060220 Red 6505A60221 6505A60220 6" (168mm) Flg/Gry ASME Class 150 Black 6505063221 N/A ASME Class 150 Red 6505A63221 ISO PN16 Red 6505A64221 6" (168mm) Flg/Flg ASME Class 150 Black 6505067221 N/A ASME Class 150 Red 6505A67221 ISO PN16 Red 6505A68221 165mm Grv/Gry N/A Red 6505A65221 N/A 165mm Flg/Gry ASME Class 150 Red 6505A66221 N/A ISO PN16 Red 6505A69221 8" (200mm) Grv/Gry N/A Black 6505080221 6505080220 Red 6505A80221 6505A80220 8" (200mm) Flg/Flg ASME Class 150 Black 6505087221 N/A ASME Class 150 Red 6505A87221 ISO PN16 Red 6505A88221 Note: For metric installations, a 2" NPT x R2. ISO 7/1 x Close Nipple (Reliable P/N 98543401) is sold separately as an adapter for the single drain outlet of the trims. a Additional equipment Component Part Mfgr. Description Technical Bulletin OS&Y - Water Supply Control Valve Select Butterfly, - Tamper Switch (Optional) for Model OS&Y2 System Sensor OS&Y Valve B A05-0196 Tamper Switch (Optional) for Model P1 BV2 System Sensor Butterfly Valve A05-0197 Deluge/Dry Valve A Model DDX-LP Reliable 518/519 Dry Pipe Valve System A Refer to Parts in this Bulletin Reliable 337/338 Waterflow Alarm Pressure Model EPS10-2 (DPDT UL, FM) System Sensor Switch B A05-0176 Model EPSA10-2 (DPDT ULC) Low Air Alarm Pressure Model EPS40-2 (DPDT UL, FM) System Sensor Switch B A05-0177 Model EPSA40-2 (DPDT ULC) Mechanical Alarm A Model C Reliable 612/613 (Optional) Manual Emergency Station A Model A Hydraulic (Pilot Line) Type Reliable 506 Sprinklers A Closed Type Reliable 110, 117, 131, 136, etc. Air Compressor C Tank Mounted Gast H-10-0801 Pressure Maintenance A Model A-2 Reliable 254 Device Accelerator Kit* A Model B1 Reliable 323 Nitrogen Regulating Device A Regulator with Optional Low Air Reliable 254 Pressure Switch *If the optional Model B1 Accelerator is used, a tank -mounted air compressor and an A-2 pressure maintenance device must be provided. Additionally the use of a tank -mounted air compressor helps to eliminate on/off compressor cycling that may occur as a result of small leakage in the system piping, as well as due to ambient temperature changes in the system piping. System Equipment Manufacturers (A) The Reliable Automatic Sprinkler Co., Inc. (B) System Sensor (C) Gast Manufacturing Corp. 10. Nominal Installation Dimensions in Inches (mm) Pipe Size A B C D* D** D*** D**** E F G H J K L M N P Q R 2" 8 7 91/2 121/2 211/4 N/A N/A 211/2 25 381/4 6 61/4 41/4 51/2 11 3 41/2 6 91/4 (50 mm) (203) (178) (241) (318) (540) (546) (635) (972) (152) (159) (108) (140) (279) (76) (114) (152) (235) 21/2" (65 mm), 3" (80 mm) & 8 7 91/2 121/2 22 N/A N/A 211/2 25 381/4 6 61/4 41/4 51/2 11 3 41/2 6 91/4 76 mm (203) (178) (241) (318) (559) (546) (635) (972) (152) (159) (108) (140) (279) (76) (114) (152) (235) 4" 71/4 71/2 10 14 241/4 16 16 211/2 25 381/4 71/2 73/4 51/2 81/4 131/2 5 63/4 41/4 113/4 (100 mm) (184) (191) (254) (356) (616) (406) (406) (546) (635) (972) (191) (197) (140) (210) (343) (127) (171) (108) (298) 6" (150 mm) & 71/4 81/2 11 16 271/2 19 19 23 271/2 403/4 8 81/4 51/2 81/4 133/4 43/4 61/2 41/4 12 165 mm (184) (215) (280) (406) (699) (483) (483) (584) (699) (1035) (203) (210) (140) (210) (349) (121) (165) (108) (305) 8" 71/4 91/4 111/2 193/a 30Y4 N/A 211/a 231/a 273/4 41 9 91/451/2 81/414Yz 3Yz 51/a 41/4123/a (200 mm) (184) (235) (292) (492) (768) (540) (591) (705) (1041) (229) (235) (140) (210) (368) (89) (133) (108) (324) D* is total takeout for Fully Assembled to Grv/Gry DDX Valve w/o Control Valve Configurations D** is total takeout for Fully Assembled to Grv/Gry DDX Valve w/ Control Valve Configurations D*** is total takeout for Fully Assembled to Flg/Gry DDX Valve w/o Control Valve Configurations D**** is total takeout for Fully Assembled to Flg/Flg DDX Valve w/o Control Valve Configurations 11. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. 0Recycled Heliabld (800) 431-Sales Offices Paper (800) 848-6051 6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www..eliablesprinkler.com Internet Address EG. Printed in U.S.A. 12/13 P/N 9999970436 CP� POTTER The Symbol of Protection Patent Pending Ordering Information Model Description Stock No. PS10-1 Pressure switch with one set 1340103 SPDT contacts PS 10-2 Pressure switch with two sets 1340104 SPDT contacts Hex Key 5250062 Cover Tamper Switch Kit 0090200 Tamper Cover incorporates tamper resistant fastener that requires a special key for removal. One key is supplied with each device. For optional cover tamper switch kit, order Stock No. 0090200. See bulletin #5401200 PSCTSK. Installation The Potter PS10 Series Pressure Actuated Switches are designed for the detection of a waterflow condition in automatic fire sprinkler systems of particular designs such as wet pipe systems with alarm check valves, dry pipe, preaction, or deluge valves. The PS10 is also suitable to provide a low pressure supervisory signal; adjustable between 4 and 15 psi (0,27 and 1,03 BAR). 1. Apply Teflon tape to the threaded male connection on the device. (Do not use pipe dope) 2. Device should be mounted in the upright position (threaded connection down). 3. Tighten the device using a wrench on the flats on the device. Wiring Instructions 1. Remove the tamper resistant screw with the special key provided. 2. Carefully place a screwdriver on the edge of the knockout and sharply apply a force sufficient to dislodge the knockout plug. See Fig 9 3. Run wires through an approved conduit connector and affix the connector to the device. 4. Connect the wires to the appropriate terminal connections for the service intended. See Figures 2,4,5, and 6. See Fig 7 for two switch, one conduit wiring. Testing The operation of the pressure alarm switch should be tested upon completion of installation and periodically thereafter in accordance with the applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). Wet System Method 1: When using PS10 and control unit with retard - connect PS10 PS10 SERIES PRESSURE SWITCH (UL, cUL, and CSFM Listed, FM and LPC Approved, NYMEA Accepted, CE Marked Pending) Dimensions: 3.78" (9,6cm)W x 3.20" (8,1cm)D x 4.22" (10,7cm)H Conduit Entrance: Two knockouts provided for 1/2" conduit. Individual switch compartments and ground screws suitable for dissimilar voltages. Enclosure: Cover - Die-cast with textured red powdercoat finish, single cover screw and rain lip. Base - Die-cast Pressure Connection: Nylon 1/2" NPT Male Factory Adjustment: 4 - 8 PSI (0,27 - 0,55 BAR) Differential: 2 PSI (0,13 BAR) typical Maximum System Pressure: 300 PSI (20,68 BAR) Switch Contacts: SPDT (Form C) 10.1 Amps at 125/250VAC, 2.0 Amps at 30VDC One SPDT in PS10-1, Two SPDT in PS10-2 Environmental Specifications: NEMA 4/IP55 Rated Enclosure - indoor or outdoor when used with NEMA 4 conduit fittings. Temperature range: -40°F to 140°F (-40°C to 60°C) Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential Occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 into alarm port piping on the input side of retard chamber and electrically connect PS10 to control unit that provides a retard to compensate for surges. Insure that no unsupervised shut-off valves are present between the alarm check valve and PSI 0. Method 2: When using the PS10 for local bell application or with a control that does not provide a retard feature - the PS 10 must be installed on the alarm outlet side of the retard chamber of the sprinkler system. Testing: Accomplished by opening the inspector's end -of -line test valve. Allow time to compensate for system or control retard. Note: Method 2 is not applicable for remote station service use, if there is an unsupervised shut-off valve between the alarm check valve and the PSI 0. Wet System With Excess Pressure Connect PSI into alarm port piping extending from alarm check valve. Retard provisions are not required. Insure that no unsupervised shut-off valves are present between the alarm check valve and the PSI 0. Testing: Accomplished by opening the water by-pass test valve or the inspector's end -of -line test valve. When using end -of -line test, allow time for excess pressure to bleed off. Dry System Connect PS10 into alarm port piping that extends from the intermediate chamber of the alarm check valve. Install on the outlet side of the in -line check valve of the alarm port piping. Insure that no unsupervised shut-off valves are present between the alarm check valve and the PSI 0. Testing: Accomplished by opening the water by-pass test valve. Note: The above tests may also activate any other circuit closer or water motor gongs that are present on the system. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. #5400928 - REV D PAGE 1 OF 3 1/08 CP� POTTER The Symbol of Protection Dimensions Fig. 1 OO 2.87 SCREWS ADJUSTMENT 172.971 KNOB ® 4.22 [107.19] 1/2" NPT 2.48 1.60 162.871 [40.641 3.78 3.20 195.891 [81.281 NOTE: To prevent leakage, apply Teflon tape sealant to male threads only. DWG# 930-1 Typical Sprinkler Applications Fig. 3 WET SYSTEM WITH EXCESS PRESSURE PS10 WATER MOTOR GONG REVS WET 7 SYSTEM ALARM CHECK VALVE WATER OS & Y BY-PASS VALVE VALVE PS10 SERIES PRESSURE SWITCH Switch Clamping Plate Terminal Fig. 2 v �p DWG# 923-3 W &WARNING An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. WET SYSTEM WITHOUT DRY SYSTEM EXCESS PRESSURE PS10 PS10 WATER WATER MOTOR MOTOR L GONG GONG CHECK REVS DRY VALVE REVS WET SYSTEM SYSTEM ALARM ALARM CHECK CHECK RETARD VALVE VALVE NVAI LR WATER OS&Y BY-PASS OS&Y BY-PASS VALVE VALVE VALVE VALVE TWO#923-2AA A CAUTION Closing of any shutoff valves between the alarm check valve and the PS 10 will render the PS 10 inoperative. To comply with NFPA-72 any such valve shall be electrically supervised with a supervisory switch such as Potter Model RBVS. Low Pressure Signal Connection Fig. 4 TO FIRE ALARM PANEL we] DWG WS-1 Waterflow Signal Connection Fig. 5 TO FIRE ALARM PANEL ace 1-1041F Local Bell For Waterflow Connection Fig. 6 NEGATIVE DC OR NEUTRAL A( POSITIVE IN OR HOT AC PRINTED IN USA MFG. #5400928 - REV D 1/08 PAGE 2 OF 3 CP� POTTER The Symbol of Protection One Conduit Wiring Fig. 7 Break out thin section of divider to provide path for wires when wiring both switches from one conduit entrance. WARNIN Fig. 8 Terminal W/ PRESSURE APPLIED C: Common Nc 1: Closed when installed under normal system c pressure. 2: Open when installed NO under normal system pressure. Closes on pressure drop. Use for low pressure supervision. ------------------------------- Terminal W/O PRESSURE APPLIED 1: Open with no pressure "c supplied. Closes upon detection of pressure. ri Use for waterflow indication. 2: Closed with no c pressure applied. •Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. -Shock hazard. Disconnect power source before servicing. Serious injury or death could result. -Read all instructions carefully and understand them before starting installation. Save instructions for future use. Failure to read and understand instructions could result in improper operation of device resulting in serious injury or death. -Risk of explosion. Not for use is hazardous locations. Serious injury or death could result. Engineer/Architect Specifications Pressure Type Waterflow Switch Pressure type waterflow switches; shall be a Model PSI as manufactured by Potter Electric Signal Company, St Louis MO., and shall be installed on the fire sprinkler system as shown and or specified herein. Switches shall be provided with a '/2" NPT male pressure connection and shall be connected to the alarm port outlet of; Wet Pipe Alarm Valves, Dry Pipe Valves, Pre -Action Valves, or Deluge Valves. The pressure switch shall be actuated when the alarm line pressure reaches 4 - 8 PSI (0,27 - 0,55 BAR). Pressure type waterflow switches shall have a maximum service pressure rating of 300 PSI (20,68 BAR) and shall be factory adjusted to operate on a pressure increase of 4 - 8 PSI (0,27 - 0,55 BAR) PS10 SERIES PRESSURE SWITCH Removing Knockouts Fig. 9 •z� -Do not tighten by grasping the switch enclosure. Use wrenching flats on the bushing only. Failure to install properly could damage the switch and cause improper operation resulting in damage to equipment and property. -To seal threads, apply Teflon tape to male threads only. Using joint compounds or cement can obstruct the pressure port inlet and result in improper device operation and damage to equipment. -Do not over tighten the device, standard piping practices apply. Pressure switch shall have one or two form C contacts, switch contact rating 10.1 Amps at 125/250 VAC, 2.0 Amps at 30 VDC. Pressure type waterflow switches shall have two conduit entrances one for each individual switch compartment to facilitate the use of dissimilar voltages for each individual switch. The cover of the pressure type waterflow switch shall be Zinc die-cast with rain lip and shall attach with one tamper resistant screw. The Pressure type waterflow switch shall be suitable for indoor or outdoor service with a NEMA 4/IP55 rating. The pressure type waterflow switch shall be UL Ulc and CSFM listed, FM and LPC approved and NYMEA accepted. PRINTED IN USA MFG. #5400928 - REV D PAGE 3 OF 3 1/08 (E)POTTER PS25 Series h The Symbol of Protection Supervisory Pressure Switch Features • Two switch model. • Independent switch adjustment, no tools needed. • Two conduit / cable entrances. • Separate isolated wiring chambers. • Non -corrosive pressure connection. • Solid metal enclosure. This document contains important information on the installation and operation of PS25 pressure switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. Installation The Potter PS25 Series Supervisory Pressure Actuated Switches are designed primarily to detect an increase and/or decrease from normal system pressure in automatic fire sprinkler systems. Typical applications are: air/nitrogen supervision in dry pipe and pre -action systems, pressure tanks, air supplies, and water supplies. The PS25-2 has two switches. The Low switch is factory set to activate at approximately 18 psi (1,2 BAR) on a decrease in pressure. The High switch is factory set to activate at approximately 28 psi (1,9 BAR) on an increase in pressure. NFPA 72 requires a supervisory signal for both high and low pressure conditions. The PS25 is factory set for a normal air pressure of 23 psi. See section heading Adjustments and Testing if other than factory set point is required. 1. Connect the PS25 to the system side of any shutoff or check valve. 2. Apply Teflon tape to the threaded male connection on the device. (Do not use pipe dope) 3. Device should be mounted in the upright position. (Threaded connection down) 4. Tighten the device using a wrench on the flats on the device. SIGNALING OLPCB c BLOus � FM LISTED Technical Specifications Dimensions 3.78"(9,6cm)Wx3.20"(8,lcm)Dx4.22"(10,7cm)H Typical 1 lb. at 10 PSI (,07 at ,7 BAR) Differential 4 lbs at 60 PSI (,28 at 4,1 BAR) Cover: Die Cast Finish: Red Powder Coat Enclosure Base: Die Cast All parts have corrosion resistant finishes Cover Tamper Cover incorporates tamper resistant fastener that requires a special key for removal. One key is supplied with each device. Factory Adjustment PS25-2 operates on increase at 28 PSI (1,9 BAR) and on decrease at 18 PSI (1,2 BAR) (2) SPDT (Form C) Switches Contact Ratings 10.1 Amps at 125/250 VAC, 2.0 Amps at 30 VDC -40° F to 140°F (-40°C to 60°C) Environmental Limitations NEMA 4/IP66 Rated Enclosure indoor or outdoor when used with NEMA 4 conduit fittings Conduit Entrances Two knockouts for 1/2" conduit provided. Individual switch compartments and ground screw suitable for dissimilar voltages Service Use NFPA 13, 13D, 13R, 72 Pressure Connection Nylon 1/2" NPT male Pressure Range 10-60 PSI (7-4,1 BAR) Maximum System 300 PSI (20,68 BAR) Pressure Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 5401564 - REV A • 06/16 PAGE 1 OF 4 (E)POTTER The Symbol of Protection Wiring Instructions 1. Remove the tamper resistant screw with the special key provided. 2. If it is necessary to remove the sealed knockouts, carefully place a screwdriver on the edge of the knockout and sharply apply a force sufficient to dislodge the knockout plug. See Fig. 9. 3. Run wires through an approved conduit connector and affix the connector to the device. A NEMA-4 rated conduit fitting is required for outdoor use. 4. Connect the wires to the appropriate terminal connections for the service intended. See Figures 2,4,5,6 and 8. Adjustment and Testing NOTE: Testing the PS25 may activate other system connected devices. The operation of the pressure supervisory switch should be tested upon completion of installation and periodically thereafter in accordance with the applicable local, national and NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). The use of a Potter BVL (see product bulletin 5400799 for details) is recommended to facilitate setting and testing of the PS25 pressure switch. When a BVL (bleeder valve) is used, the pressure to the switch can be isolated and bled from the exhaust port on the BVL without affecting the supervisory pressure of the entire system. See Fig. 3. The operation point of the PS25 Pressure Switch can be adjusted to any point between 10 and 60 PSI (0,7 - 4,11 BAR) by turning the adjustment knob(s) clockwise to raise the actuation point and counter clockwise to lower the actuation point. In the case of the PS25-2, both switches operate independent of each other. Each switch may be independently adjusted to actuate at any point across the switch adjustment range. If the pressure needs to be adjusted from the factory settings, adjust the system pressure to the desired trip point. Use an ohmmeter on the appropriate contact (COM and 2 for pressure decrease and COM and 1 for pressure increase). Adjust the knurled knob until the meter changes state. At that point the switch is set for that particular pressure. Final adjustments should be verified with a pressure gauge. The position of the top of the adjustment knob across to the printed scale on the switch bracket can be used to provide an approximate visual reference of the pressure switch setting. Dimensions Fig I 0O SCREWS 2.87 SCR ADJUSTMENT [72.97] 1 KNOB ® 4.22 [107.17.19] 1/2" NPT 2.48 1.60 [62.871 [40.641 3.78 3.20 195.89] [81.281 NOTE: To prevent leakage, apply Teflon tape sealant to male threads only. DWG# 930-1 PS25 Series Supervisory Pressure Switch Switch Terminal Connections Clamping Plate Terminal Fig 2 OW, I AWARNING IM An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. Typical Sprinkler Applications Fig 3 PS25 SUPERVISORY PRESSURE SWITCH AIR LINE SHUT-OFF PS10 VALVE BLEEDER ALARM TEST PRESSURE CHECK VALVE SWITCH VALVE BVL DRY PIPE VALVE NTEST DWG.#924-lA OS&Y VALVE WATER MOTOR GONG � A CAUTION Closing of any shutoff valves between the alarm check valve and the PS25 will render the PS25 inoperative. To comply with IBC, IFC, and NFPA-13, any such valve shall be electrically su- pervised with a supervisory switch such as Potter Model RBVS. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 5401564 - REV A • 06/16 PAGE 2 OF 4 (E)POTTER The Symbol of Protection Typical Electrical Connections Fig 4 TO FIRE ALARM PANEL HIGH AIR LOW AIR WITH NORMAL SYSTEM PRESSURE APPLIED HIGH - TERMINAL 1 WILL CLOSE ON PRESSURE INCREASE. WITH NORMAL SYSTEM PRESSURE APPLIED LOW -TERMINAL 2 CLOSES ON PRESSURE DROP. Low Pressure Signal Connection F;5 DWG# 928-1 High Pressure Signal Connection Fig 6 TO FIRE ALARM PANEL DWG# 928-2 PS25 Series Supervisory Pressure Switch One Conduit Wiring Fig 7 Changing Pressure Fig 8 Low Pressure Switch High Pressure Switch C g C 1 2 C 1 2 Terminal Terminal C: Common 1. Open when installed 1. Closed when installed under normal system under normal system pressure. Closes on Pressure. increase in pressure. Use 2. Open when installed for high air signal. under normal system 2. Closed under normal pressure. Closes on system pressure. pressure drop. Use for low air signal. Removing Knockouts Fig 9 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 5401564 - REV A • 06/16 PAGE 3 OF 4 (E)POTTER The Symbol of Protection Engineer/Architect Specifications Pressure Type Waterflow Switch Pressure type supervisory switches; shall be a Model PS25 as manufactured by Potter Electric Signal Company, St. Louis, MO., and shall be installed on the fire sprinkler system as shown and or specified herein. Switches shall be provided with a 1/2" NPT male pressure connection to be connected into the air supply line on the system side of any shut- off valve. A Model BVL bleeder valve as supplied by Potter Electric Signal Company of St. Louis, MO., or equivalent shall be connected in line with the PS25 to provide a means of testing the operation of the supervisory switch. (See Fig. 3) The switch unit shall contain SPDT (Form C) switch(es). One switch shall be set to operate at 18 psi (1,2 BAR) on a pressure decrease. The second switch shall be set to operate at a 28 psi (2,9 BAR) on a pressure increase. Switch contacts shall be rated at 10.1 Amps at 125/250VAC and 2.0 Amps at 30VDC. The units shall have a maximum pressure rating of 300 PSI (20,68 BAR) and shall be adjustable from 10 to 60 PSI (0,7 to 4,1 BAR). Pressure switches shall have two conduit entrances, one for each individual switch compartment to facilitate the use of dissimilar voltages for each individual switch. The cover of the pressure switch shall be zinc die-cast with rain lip and shall attach with one tamper resistant screw. The pressure switch shall be suitable for indoor or outdoor service with a NEMA-4/IP66 rating. The pressure switch shall be UL, ULC, and CSFM listed, FM and LPC approved and NYMEA accepted. PS25 Series Supervisory Pressure Switch Ordering Information Model Description Stock No. PS25-2 Pressure Switch with two sets SPDT contacts 1340425 Hex Key 5250062 BVL Bleeder Valve 1000018 Optional Cover Tamper Switch Kit 0090200 M AWARNING *Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. -Shock hazard. Disconnect power source before servicing. Serious injury or death could result. -Read all instructions carefully and understand them before starting installation. Save instructions for future use. Failure to read and understand instructions could result in improper operation of device resulting in serious injury or death. -Risk of explosion. Not for use is hazardous locations. Serious injury or death could result. A CAUTION -Do not tighten by grasping the switch enclosure. Use wrenching flats on the bushing only. Failure to install properly could damage the switch and cause improper operation resulting in damage to equipment and property. -To seal threads, apply Teflon tape to male threads only. Using joint compounds or cement can obstruct the pressure port inlet and result in improper device operation and damage to equipment. -Do not over tighten the device, standard piping practices apply. -Do not apply any lubricant to any component of the pressure switch. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com iso sooi:zoos DESIGNING, MANUFACTURING, & DISTRIBUTING QUALITY SYSTEMS 5401564 - REV A 06/16 PAGE 4 of 4 Bulletin 251 Rev. V May 2018 Reliable cULus Listed Models A, A-2, B, & B-1 Automatic Pressure Maintenance Devices FM Approved Product Description Models A/A-2 Pressure Maintenance Device The Model A/A-2 Pressure Maintenance Device (PMD) is de- signed for use where a source of compressed air (plant air sys- tem, tank -mounted compressor with a pressure control, etc.) or nitrogen cylinder (equipped with a regulating device) is available. The regulator in the Model A/A-2 PMD reduces higher pressure air or nitrogen to a level required by a dry pipe valve, dry pilot line, or a deluge valve based preaction system. The Model A/A-2 PMD will maintain a constant pressure in the system regardless of any pressure fluctuations from the compressed air or nitrogen source. Basic functionality of components (refer to Fig. 1): The strainer's function is to prevent any foreign matter that may be present in the air supply, from traveling to the regulator and the check valve, thereby ensuring their normal operation. The check valve's func- tion is to prevent the reverse flow of water resulting from a dry pipe or deluge valve's operation, from reaching the regulator. Two 1/4" valves allow for the servicing (if needed) of the strainer and reg- ulator without having to shut down the sprinkler system. The 1/2" ball valve permits the rapid restoration (quick -fill) of the required system air pressure during commissioning, or after service or op- eration. The 1/2" ball valve must be closed and the 1/4" valves must be open for proper automatic operation. Models 13/13-1 Pressure Maintenance Device The Model B/B-1 Pressure Maintenance Device (PMD) is de- signed for use in conjunction with a tankless air compressor with- out a pressure control switch to maintain the correct air pressure in a dry pipe valve, dry pilot line, or a deluge valve based preaction system. Basic functionality of components (refer to Figure 2): A drop in the sprinkler system's air pressure causes the contacts of the pressure switch to close, thereby activating the air compressor. When the pre -adjusted level of air pressure is restored, the pressure switch's contacts re -open, thereby deactivating the air compressor. The pressure switch is also equipped with an unloader valve that au- tomatically bleeds off the air compressor's outlet pressure each time the contacts of the pressure switch open. This protects the air compressor's motor from overloading during startup. Like the Model A/A-2 PMD, the Model B/B-1 has a strainer for contamina- tion control and a check valve to prevent reverse water flow. The 1/2" ball valve and 1/4" valves are also identical in configuration and function as with the Model A/A-2 PMD. Likewise, the 1/2" ball valve must be closed and the 1/4" valves must be open for proper automatic operation. Model A Pressure Maintenance Device Model A-2 Pressure Maintenance Device ­-N Model B Pressure Maintenance Device Model B-1 Pressure Maintenance Device www.reliablesprinkler.com Outlet Pressure Range: 5 — 100 psi (0,34 — 6,9 bar) Maximum Inlet Pressure: 175 psi (12 bar) Inlet/Outlet Threads: 1/2" NPT (A); 3/4" NPT (A-2) The pressure regulator is factory set to maintain a nominal system air or nitrogen pressure of 23 psi (1,6 bar). In order to change the outlet pressure, loosen the locknut at the top of regulator and turn the adjustment screw clockwise to increase pressure. To decrease the pressure, turn the adjusting screw counter clockwise. The resulting pressure can be determined at the sprinkler system air gauge, or the optional gauge location provided on the device, once the flow or air or nitrogen through the device has ceased. Note: The locknut of the regulator must be tightened after adjusting in order to prevent an accidental change in the pressure setting. Installation Install the pressure maintenance device in the line between the com- pressed air or nitrogen supply and the dry pipe system, preaction system, or dry pilot line detection system. The supply for the Model A/A-2 Pressure Maintenance Device can be a tank -mounted com- pressor (dedicated or plant air), a nitrogen generator with a tank, or bottled nitrogen with a high pressure regulator. Install the Model A/A- 2 as close to the dry pipe valve, deluge valve, or preaction system technical bulletins for additional information. Model A Model A-2 Model A/A-2 Pressure Maintenance Device Note: It is imperative that the entire air or nitrogen supply sys- tem be tested and made leak -free. Leaks in the supply sys- tem will result in excessive compressor operation, depletion of bottled nitrogen, and possible unintended release of the fire protection system. Model A Pressure Maintenance Device P/N 6304001123 (23psi), (All steel pipe fittings are galvanized) Item No. part No. Description oty. 1 96606607 TEE, 1/2" X 1/2" X 1/4" 2 2 96606608 TEE, 1/4" X 1/4" X 1/4" 1 3 98174404 ELL, 1/4" 1 4 98543210 NIPPLE, 112" X 2-1/2" 1 5 98543227 NIPPLE, 1/4" X CLO 6 6 98614403 SQ. HEAD PLUG, 1/4" 1 7 98681630 REGULATOR, 1/4", 5 - 100 PSI 1 8 98727607 STRAINER, 1/4" 1 9 98815201 G.J. UNION, 1/4" 2 10 98840147 CHECK VALVE, 1/4" INLINE POPPET 1 11 98840237 BALL VALVE, 1/4" NPTM X NPTF 2 12 9884011E BALL VALVE, 1/2" NPTM X NPTF 1 Bulletin 251 Rev. V May 2018 Page 2 of 4 www.reliablesprinkler.com Pressure Switch Adjustment Range: 14-60 psi (1,0-4,1 bar) Maximum Inlet Pressure: 175 psi (12 bar) Inlet/Outlet Threads: 1/2" NPT (B); 3/4" NPT (13-1) WARNING: Disconnect power to the Model 13/1113-1 Pressure Maintenance Device prior to opening the pressure switch cover. The pressure switch is factory set to start the compressor at 27 psi (1,9 bar) and stop the compressor at 35 psi (2,4 bar). In order to change the setting, remove the pressure switch's cover and follow the directions contained within the switch. Verify the start and stop pressures at the sprinkler system air gauge, or at the optional gauge location provided on the de- vice. Note: Adjustment of the differential between the start and stop pres- sures of the compressor is not recommended. Electrical Rating: Single Phase: 120 Volts AC; 2 hp 240 Volts AC; 3 hp 600 Volts AC; 5 hp Three Phase: 240 Volts AC; 5 hp 600 Volts AC; 5 hp 115-230 Volts DC; 3 hp Installation Install the pressure maintenance device in the line between the com- pressed air or nitrogen supply and the dry pipe system, preaction system, or dry pilot line detection system. The supply for the Model 13/13-1 Pressure Maintenance Device is a tank -less compressor with- out a pressure switch. Install the Model 13/13-1 as close to the dry pipe valve, deluge valve, or preaction system technical bulletins for additional information. Note: It is imperative that the entire air or nitrogen supply system be tested and made leak -free. Leaks in the supply system will result in excessive compressor operation, depletion of bottled nitrogen, and possible unintended release of the fire protection system. Model B Pressure Maintenance Device 17 11 10 4 7 3 e z 9 *OPTIONAL 7 b PRESSURE 12 GAUGE 13 LOCATION s e 11 13 15 e 15 1 16 6 1 Model 13/13-1 Pressure Maintenance Device Model B/B-1 Pressure Maintenance Device Wiring: Remove the pressure switch's cover and connect the wiring in accordance with the National Electric Code or other appropri- ate standards. The connections should be as shown in Figure 3 for single phase wiring of thermally protected compressor motors. For 3-phase wiring, a listed and/or approved, properly sized magnetic motor starter with appropriate NEMA enclosure must be provided. The wiring of the pressure switch, motor starter, and air compressor must be in accordance with the National Electrical Code, or other appropriate standards. Model B/B-1 PMD Electrical Connections Air Compressor (REF. WIRING DIAGRAM ATTACHED TO AIR COMPRESSOR) Model B Pressure Maintenance Device P/N 6304012100 (All steel pipe fittings are galvanized) Item No. Part No. Description Oty. 1 96606607 TEE, 1/2" X 1/2" X 1/4" 2 2 96606608 TEE, 1/4" X 1/4" X 1/4" 1 3 98048034 BUSHING, 3/8" X 1/4" 1 4 98085630 CONNECTOR, 1/4' TUBING X 1/4" NPT 1 5 98523100 RESTRICTION ORIFICE 1 6 98543223 NIPPLE, 1/2" X 1-1/2" 1 7 98543226 NIPPLE, 1/4" X 1-1/2" 2 8 98543227 NIPPLE, 1/4" X CLO 3 9 98614403 SQ. HEAD PLUG, 1/4" 1 10 98727607 STRAINER, 1/4" 1 11 98728801 PRESSURE SWITCH;14 PSI TO 60 PSI 1 12 98750004 CROSS, 1/4" 1 13 98815201 G.J. UNION, 1/4" 2 14 98840147 CHECK VALVE, 1/4" INLINE POPPET 1 15 98840237 BALL VALVE, 1/4" NPTM X NPTF 2 16 9884011E BALL VALVE, 1/2" NPTM X NPTF 1 17 98768000 COPPER TUBING, 1/4" 181, Bulletin 251 Rev. V May 2018 Page 3 of 4 www.reliablesprinkler.com Maintenance Refer to Figures 1 & 2. 1. Review the latest NFPA 13 and NFPA 25 Standards, any appropriate dry pipe or deluge valve installation bulletins, and the section in this bulletin titled "Installation" to ensure that the pressure maintenance device is installed properly. 2. Make sure that both 1/4" valves are open and that the 1/2" ball valve is closed. 3. Check the gas pressure in the dry pipe, deluge or preac- tion system at the pressure gauge located on those devic- es. See the section titled "Adjustment" if any are required. 4. If maintenance is to be performed on the strainer, regula- tor, or pressure switch of the pressure maintenance device, make sure that both 1/4" valves are closed and that pres- sure has been relieved from the section through the union. These 1/4" valves must be opened again in order to restore proper automatic operation. 5. The strainer should be cleaned periodically to prevent contamination from blocking air flow. This can be done by removing the strainer's cap and wiping or blowing off any collected debris. 6. Make sure the check valve is installed according to the schematic with the arrow on its hexagonal side pointing in the required direction of air flow. 7. If the regulator in the Model A/A-2 Pressure Maintenance Device is constantly leaking at the adjusting screw, the regulator may contain dirt keeping the poppet open and should be cleaned or replaced. 8. Check the inside housing of pressure switch of the Mod- el 13/13-1 Pressure Maintenance Device for dirt or foreign matter and verify that the wiring is fastened securely and is wiring insulation is in good condition. Listings and Approvals • Listed by Underwriters Laboratories, Inc. and Underwriters Laboratories of Canada. (cULus) • FM Approved Guarantee For Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Ordering Information Specify: Model: [A Pressure Maintenance Device] [A-2 Pressure Maintenance Device] [B Pressure Maintenance Device] [13-1 Pressure Maintenance Device] a Bulletin 251 Rev. V ��';��'� Page 4 of 4 May 2018 www.reliablesprinkler.com :r...;: - #:',::'ls:�::4 '- 9c;a<j"i-..: ;•-i"; :5::., S:i - ::'a l�;'!9:: . i,.'RIR}:e .r'.:l'•:' i:' i?,*- fir''•=,•.. .. •a•,•.... ...: ... -,. ... ) .,+ e., ... ..l.. t... u)r} rr .r.. :A,/.J..: �+ir.•, r'l::::-it Y t,•R.,r• . ry,,S 7 , ..4 . Y_ L .r .{ ,.f.., a F,: f• ...:,:. .. ,,. ,.. t t ✓':. "..: , a•.•.,,:.......Ld_. f, ,1 .. t:r;r..s..t r. t_ :�;r :: •:i)ea,l;.......,..:g:+ ar.,_.,:'.;�, : 4. , .�. A My 1 / „i r_,. _ .: ,.:.... ..._., w , f : 5R1• 1. .) _. • ..• - f. - :R � ,J t I -L] w fit ,t •r' •-t RT ' , r.i •5 - l k. Y '. ` i :'1!. ....tt.. r3a F t � n 5. ;: rt: ...; �r _.^. i. :., .5a 1ht,1T l,,}/:;.,'� 4•, t ,' , u`:. Y♦i' :•P: s el- ,. _Y_ a •':. _ •: :i:1.....::, : .L: µl,.,f�t t •r%��'�ti e.:1�i • .�. - '. J. ):.: � •••' a e � •rY• , u L r. J•) V f a r s a :;L•t- 7 Pr 1 t K M•.i... . L . .a. fL ASl�. 1.. ,a 'y •t .� ,r .Y. 4• Z ,i�� r, tsl 'YY ry ei,, Wit' . •r;5�r •.r,r1.r.:i.: . •iµ vn k ., •a t. - .I .a ..:r „.. 7 ., .,. x.i.it ! .....,r.L_e.;: : .-5, ...:z;,.}�a�?`Sm w. .: •, :,. s ,R 0 .f �. • : .:py�•, s;"crmzl: fY+f� +}>;rr sfckvy';y 7 L "S�r�+,�'.n.:zl!,a:t'- .. ,. ... ' �t�yr, 5 ,... r..:e! 'r� P�..-et,;'.;f,<y1f'{�._�.�Fk}tt:.,.±R'...,,.,d• ., : ,s .,C ts_�, :::az• 7' R :,.., .{i,F 1 ,.,.:......,...:x..., �S. L:: �. C?i.,:.w,.3t..,•.±. 9;•.t. _. .t ...: :.:: v,. i.. ,...:i t ,,5.;i: to -a+,. r}.y..:•t$:: ,tCF•: - .:�r: �. rr.'' �, :. ..r,,...: ..:-. .:.. ..... ...... rr;.. ...,:''x. x `? ':.i�z at_. ,.E�i .:rj�i �" i ,...:.iv{''. J-S ' ,.. .lKf7Z R7-aFp. A.Jp ,. a f v.,,.,i: :,L.. .r,,. i.:, ,y .,:,,•u.. ,a-,'+,ir�,rv.}� +Y k,t�:t:, r... a .,. „n,,. l.r,.,.a ..:4': ...: .ar •, ..a ..-[ri<.. � .f Y.:.FN r. .Y.. n:.:,. M}f•y ..i ::}. j' P L - m a Oilless Piston Air Comp Features • Motor -mounted, no belts or pulleys • Oil free air, no lubrication required • Corrosion resistant internal parts • Compact, lightweight and easy to install • Regardless of Cause Warranty Side View Front View ;.'i•''.�.�2. Div. 'c?:�»�:�:.�,�_.�..F_?::1;%,•.. � }sg. .?ft Dimensional Data (in.) Pipe Model Number A B C Size 2LAF-11T M200X 26.00 15.65 20.75 114" NPT 4LCB-11T-M450X 33.00 17.20 26.13 1/4" NPT to �4 -t l :q - o11� -t :lsk�rt� -c a�.v mI 4*On 6LCF-11T M616X 38.00 18.29 28.38 318" NPT Maximum Gallons CFM in System Free To Pump Air To 40 PSI in @ 30 Minutes 40 PSI Motor Data Tank PackageASME coded tank mounted compressors include gauge, pressure switch (minimum switch differential is 10-13 psig), shut-off valve, drain valve, check valve and safety valve. Side View -A Front View Dimensional Data (in.) Pipe Model Number D E F Size 3-1 T= M750X 38.00 1$ (t10: 8LDF-1ITC-M850X 38.00 18.29 28.38 1/2" NPT Tankless Tank -Mounted Packages Packages 150 1.5 114 hp,115-60-1 2LAF-12-M200X 51, 444. AN 111 300 3.1 1/2 hp,1151230-60-1 4LCB-21-M450X 460.: , k ,4 . , = 14: ,� °: '::: _ ;:...SPCA-22-M550X 600 5.9 1 hp, I1' /i 0-60-1 6LCF-1 3 -M616X 5.0.0 7.9 1112 R, f' � s??30=:£?�,- ry.: 1. DE-16-M750X 1000 10.7 2 hp, 1151230; 8LDF-16-M850X 1101220-60/50-1 2LAF-11T M200X (12 4LCB-11T M450X (20 gallon) 51LCA=11 T 1V15s0X (2iFS?E[i) 6LCF-11T-M616X (30 gallon) 7LOE-11 TrNIZS(?X.. (3�'�aTl`ari) 8LDF-I ITC-M850X(30 gallon) ;sors for Dry Sprinkler Systems Air Capacity of A System Capacity of 1 Foot of Pipe (Based on actual internal diameter) Diameter Gallons 112 in. 314 in. .028 1 in. .045:. . 1 1/4 in. .078 1 112 in. 106 2 in. .174 21/2 in. 248 3 in. .383 3 in: 4 in. .660 5 in 1 I40 6 in. 1.501 �6 �ti Tankless/Automatic air compres- sors have inlet filters, a safety valve, pressure switch (minimum switch differential is 10-13 psig on most models) , check valve, tubing and fittings. The 2LAF-12-M200X has 6 psig minimum differential. Motors - All air compressors shown have open motors. Single phase motors have internal thermal protection. Dual voltage motors are shipped pre -wired for the higher voltage. (All tank mounted units, with the exception of the 8LDF series, are wired for 115 volts.) Dimensional Data (in.) Pipe Model Number A B C Size -1AA 3 i![1f O 8�8 °,, x i4" NP ._ > 2LAF 12-M200X 8.38 14.38 10.88 1/4" NPT 4LC B-21-M450X 8.88 14.75 12.00 1/4" NPT 6LCF-13-M616X 9.00 17.5 13.00 1/4" NPT Dimensional Data (in.) Pipe Model Number D E F Size 7L0E6M4 a8:$8Ek ;3 3'1.8"NPT 8LDF-16-M850X 8.70 24.06 1169 1/2" NPT Accessories Part Number Description A4550 - ;check AJ550A Check valve 3/8"NPT female AK289; " RrsprmQROW0, ' AK620 Pressure switch y `minimum``' psig pressure differential) 'E163A AE163B AF564 AF631 AF633 Pressure switch, cut -in pressure 40 psi, cut-out pressure 50 psi PC ,",ur� E� � her �ti� - x 1 k 'L 1: (20 psig t l es r�r� 3}ffer6htia1), Shocklisolation mounts 1/4-20 #hread (both ends) (48 frame) 6-18 thread (both Side View Front View Top View Front View Compressor mounting bracket comes complete with all the hardware and adjustable stainless steel straps for mounting Gast tankless air compressors to all sizes of riser pipes. To order, contact your local sprinkler supply company or your local Gast distributor and ask for Gast part number AK289. Refer to NFPA 13 Chapter 5-2 (Dry Pipe Systems) for limitations and requirements of air supplies UL Fire Protection Listing VDUR 0 UL Air Compressors- Special 'type MP1448(N) (Listed in the Fire Protection Directory) Models 1 LA-M100X„ 2LA-M200X, 3LB-M300X, 4LC-M450X, 5LC-M550X, 6LC-M616X, 7LD-M750X, 8LD-M850X are single -stage, positive -displacement type air pumps with integral motor, both stand alone and tank - mounted. QDFT2 Component -Painting Equipment, Air Compressor, Vacuum Pumps E75450 Compressors Models 1 HA,1 LA, 21-113, 21-6,31-113, 31-13, 4HC, 4LC, 5HC, 5LC followed by any letter A to L incl., followed by two digit numbers 00 to 99 incl., followed by any letter A to Z incl., followed by letter M, followed by three digit numbers 100 to 699 incl., followed by letter X, Y. or Z. Guide No. 22-1-0 Class 3811 Air Compressors LR37697 Piston pumps, stationary, compressor or vacuum Series 1 LA, 2LB, 31-13, 4LC, 5LC,1 HA, 21-113, 31-16, 4HC, 5HC, 5VS, 5VD, 6LD,6HD, 7LD, 7HD,1 VA,1 VS,1 VB, 4VC, 4VS, 575v max. single and three phase, 50l60 Hz, 2hp max. Series followed by suffix numbers and letters to form model designation or (XXXX) replaced in Series to form model designation. Note: Three phase motor models not recognized by UL. For Your GAST Fire Protection Equipment Contact Gast Eastern Sales Office 505 Washington Avenue Carlstadt, NJ 07072 Ph: 201 /933-8484 Fax: 201 /933-5545 Gast Corporate Headquarters Post Office Box 97 2300 M-139 Highway Benton Harbor, Michigan Ph: 616/926-6171 Fax: 616/927-0860 Gast Midwestern Sales Offices 755 North Edgewood Wood Dale, IL 60191 Ph: 630/860-7477 Fax: 630/860-1748 Gast Customer Sales 2550 Meadowbrook Road Benton Harbor, MI. 49022 Ph. 616/926-6171 Fax: 616/925-8288 Gast European Sales Office Beech House Knaves Beech Business Centre Loudwater, High Wycombe Bucks, England HP10 9SD Ph:1628 532600 (00 44 ) Fax: 1628 532470 (00 44 ) Gast Hong Kong Unit 3,19/F Block E Wah Lok Industrial Centre 31-35 Shan Mei Street Fo Tan, N. T. Hong Kong Ph: (852) 26901008 Fax: (852) 2690-1012 MODEL 1011T & V: UnAm D jC)aAm FM 4 • w w USA PATENT AND OTH ❑ -The AGFManufacturing Inc.Model 1011TMatchesAII 7he FeaturesAnd Benefits Of Our Model 1000 And Model 1011 TESTANDRAIN Valves By Providing Both The Test Function And The Express Drain Function,With The Added Features Of An Integral Model 7000 Pressure Relief Valve, Model 7500 Pressure Gauge,and Model 7600 1/4"3-Way Globe Valve. ❑ The Model 1011TIsACompact Single Handle BallValve,Which IncludesA Tamper Resistant Test Orifice, Integral Tamper Resistant Sight Glass,And Is300 PSI Rated. ❑ The Model 1011TCompliesWith The Requirements Of NFPA 13, 13R,& 13D,Which Stipulate A Pressure Relief Valve Be Installed On All Gridded SystemsAnd Downstream OfAII Pressure Reducing Valves. ❑ Designed To Relieve Excess System Pressure Caused By Surges Or Temperature Changes As Well As Solve The Difficult Problem Of Providing The Relief Valve With A Drainage -Piping Outlet. ❑ Available In A Full Range Of Sizes From 3/4"To 2", NPT& BSPTWith All Specifiable Orifice Szes3/8", '/16", 1/2", 17/32", 5/8" (ELO), & 3/4" (ESFR). ❑ The Model 1011TIsShipped Complete With All Necessary Components Including The UUFM Model 7500 300 PSI 31/2" Pressure Gauge And UU FM Model 7600 1/4" 3-Way Globe Valve. ❑ To Expedite stem Testing The Unit Is Shipped Semi -Assembled With The Relief Valve PbrtAnd The Bypass Drain Fbrt Plugged. ❑ The Included UUFM Model 7000 Pressure Relief Valve FeaturesA Rushing Handle And Is Factory Set At 175 PSI, Other Pressure SettingsAre Also Available. Okout our Autocgo re G on TheVisit Inteusrnet at 8/01 MODEL 1011T � 4 MODEL 1011 (UL LISTED/FM APPROVED) BRONZE BALL VALVE MODEL 7000 (UL LISTED/FM APPROVED) PRESSURE RELIEF VALVE FACTORY SET AT 175 PSI WITH OTHER SETTINGS AVAILABLE. MODEL 7500 (UL LISTED/FM APPROVED) PRESSURE GAUGE MODEL 7600 (UL LISTED/FM APPROVED) '/4' 3-WAY GLOBE VALVE t,5� ,2°5 O125 150 175 FRONT VIEW _° AF 2, 5... 250 MODEL 1011 T G`O 3015 F INLET A o � E ® O G 0 o� pOO o7 TEST 7 DRAIN o " Oj � 00 Oo 2 0 G 5 1 (D 0 10 PARTS LIST Model 1011 T QtY. Dwg Ref: Model 1011 TESTANDRAIN Valve 1 1 Model 7000 Pressure Relief Valve 1 2 Model 7500 Pressure Gauge 1 3 Model 7600'id' 3-Way Valve 1 4 'iz' x 14z' NPT Nipple 1 5 1/2" x 1/2" x 114' Tee 1 6 '/d' Nipple & plug 1 7&8 21/2" NPT x Barb 90" Elbows 2 9 1 - N Iobraid Drain Tubing 1 10 2 - 11l,6' Clamps 2 11 SIZE A B C D E 3q. 10'/4' 256 mm 3 /a" 84 mm 8 /4' 119 mm 4 9/16' 114 mm 13 3/s" 334 mm 1 rr 101/4' 256 mm 3 /a' 84 mm 8 /4 119 mm 4 9/16' 114 mm 13 3/s" 334 mm 1 1� rr 10 1/2" 3 5/8" 9" 5 9/16' 14 1/2' 4 263 mm 91 mm 225 mm 139 mm 363 mm rr 1 1)2 /16' 242 mm 8 1/4' 206 min 17 7/a' 447 mm 11 '/z" 288 mm 3 7/8" 97 mm 21 11 1/2" 288 mm 3 7/a' 97 mm 9"/16' 242 mm 8 1/4' 206 mm 17 7/s" 447 mm ORIFICE SIZES AVAILABLE - 3/8, All metric measurements rounded to the nearest whole number. 7/16, 1/2, 17/32, ELO(5/8)', ESFR (3/4)' *Available on 11/4" to 2" size units only. The Model 1011 T answers all of the following ... From the 1999 Edition of NFPA 13 Chapter 5-14.2.4.1 Provisions shall be made to properly drain all parts of the system Chapter 5-15.4.1 Main drain test connections shall be provided at locations that will permit flow tests of water supplies and connections. Chapter 5-15.4.2 An alarm test connection not less than 1" terminating in a smooth bore corrosion resistant orifice, giving a flow equivalent to one sprinkler of a type having the smallest orifice shall be provided to test each waterflow alarm device. Chapter 5-15.4.2(A) If a test connection is terminated into a drain riser you must use an approved sight test connection to view flow. Chapter 5-15.3 A pressure gauge shall be installed at the system main drain, at each main drain associated with a floor control valve, and on the inlet and outlet side of each pressure -reducing valve. Each gauge connection shall be equipped with a shutoff valve and provisions for draining. Chapter 4-1.2 Requires ALL GRIDDED SYSTEMS be provided with a relief valves Chapter 5-14.1.2.3 Requires a relief valve be installed downstream of all pressure -reducing valves. Chapter 5-14.1.2.3 Consideration should be given to piping the discharge from a relief valve. UL LISTING EX4019(N) & EX4533(N) AGF MANUFACTURING INC. 100 Quaker Lane Malvern, PA 19355 USA Telephone: (610) 240-4900 WWWWO Fax: (610) 240-4906 www.testandrain.com MADE IN U.S.A. JOB NAME: ARCHITECT: ENGINEER: CONTRACTOR: Model 8000 RESIDENTIAL RIsll=_RPACK® Pre Assembled Riser for NFPA 13D Systems Assembly includes: bronze riser body w/ imprinted signage, water flow alarm switch w/ retard, 3'/z" pressure gauge, appropriately sized drain valve w/ specific TEST orifice, sight glass option available, non retard flow switch special order W11— 7 AGF Item ID Item Description Item Class Master Carton Minimum Order Oty. Unit 1 " M8000 81001) 1 " M8000 x 3.0k-A Orifice Assembly 1 1 EACH Thread 8101 D 1 " M8000 x 3.7k-B Orifice Assembly 1 1 EACH '� 8102D 1 " M8000 x 4.3k-C Orifice Assembly 1 1 EACH 8103D 1" M8000 x 5.5k-D Orifice Assembly 1 1 EACH 11/4" M8000 811 OD 11/4" M8000 x 3/8" Orifice Assembly 1 1 EACH Thread 8111 D 11/4" M8000 x 7/16" Orifice Assembly 1 1 EACH 8112D 1'/4" M8000 x'/z" Orifice Assembly 1 1 EACH 8113D 11/4" M8000 x'7/32" Orifice Assembly 1 1 EACH 8114D 1'/4" M8000 x 5/8" ELO Orifice Assembly 1 1 EACH 11/2" M8000 8120D 1'h" M8000 (THD) x 3/8" Orifice Assembly 1 1 EACH Thread 8121 D 1'/z" M8000 (THD) x 7/16" Orifice Assembly 1 1 EACH 8122D 1'/z" M8000 (THD) x'/2" Orifice Assembly 1 1 EACH _ 8123D 1'/z" M8000 (THD) x'7/32" Orifice Assembly 1 1 EACH 8124D 11/2" M8000 (THD) x 5/8" ELO Orifice Assembly 1 1 EACH 11/2" M8000 8125D 1'/z" M8000 (THD x GRV) x 3/8" Orifice Assembly 1 1 EACH Thread x Groove 8126D 1'h" M8000 (THD x GRV) x 7/16" Orifice Assembly 1 1 EACH 8127D 1'/z" M8000 (THD x GRV) x'/2" Orifice Assembly 1 1 EACH 8128D 1'/z" M8000 (THD x GRV) x'7/32" Orifice Assembly 1 1 EACH 8129D 11/2" M8000 (THD x GRV) x 5/8" ELO Orifice Assembly 1 1 EACH 11/2" M8000 8130D 1'/z" M8000 (GRV) x 3/8" Orifice Assembly 1 1 EACH Groove 8131 D 1'/z" M8000 (GRV) x 7/16" Orifice Assembly 1 1 EACH 8132D 1'h" M8000 (GRV) x'h" Orifice Assembly 1 1 EACH 8133D 1'/z" M8000 (GRV) x 17/32" Orifice Assembly 1 1 EACH 8134D 1'/z" M8000 (GRV) x 5/8" ELO Orifice Assembly 1 1 EACH 2" M8000 8140D 2" M8000 (THD) x 3/8" Orifice Assembly 1 1 EACH Thread 8141 D 2" M8000 (THD) x 7/16" Orifice Assembly 1 1 EACH 8142D 2" M8000 (THD) x %2" Orifice Assembly 1 1 EACH till— 8143D 2" M8000 (THD) x 1�/32" Orifice Assembly 1 1 EACH 8144D 2" M8000 (THD) x 5/8" ELO Orifice Assembly 1 1 EACH 2" M8000 8145D 2" M8000 (THD x GRV) x 3/8'' Orifice Assembly 1 1 EACH Thread x Groove 8146D 2" M8000 (THD x GRV) x 7/16" Orifice Assembly 1 1 EACH 8147D 2" M8000 (THD x GRV) x'/2" Orifice Assembly 1 1 EACH 8148D 2" M8000 (THD x GRV) x 17/32" Orifice Assembly 1 1 EACH 8149D 2" M8000 (THD x GRV) x 5/8" ELO Orifice Assembly 1 1 EACH 2" M8000 8150D 2" M8000 (GRV) x 3/8" Orifice Assembly 1 1 EACH Groove 8151 D 2" M8000 (GRV) x �/16" Orifice Assembly 1 1 EACH 8152D 2" M8000 (GRV) x'/z" Orifice Assembly 1 1 EACH 8153D 2" M8000 (GRV) x'7/32" Orifice Assembly 1 1 EACH 8154D 2" M8000 (GRV) x 5/8" ELO Orifice Assembly 1 1 EACH Product Information V008.0 15 AF Model 8011 RESIDENTIAL RISERPACK® Pre Assembled Riser for NFPA 13D Systems Requiring Pressure Relief Assembly includes: bronze riser body w/ imprinted signage, water flow alarm switch w/ retard, 31/2" pressure gauge, appropriately sized drain valve w/ specific TEST orifice, pressure relief valve w/ drain trim, sight glass option available, non retard flow switch special order M8011 valves are packaged with a trim kit. The trim kit includes a 175 PSI rated M7000 PRV and drain trim. M7000 valves are also available in PSI ratings of 165, 185, 195, 205, 225, and 250. Note: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. AGF Item ID Item Description Item Class Master Carton Minimum Order Oty. Unit 1" M8011 8200D 1" M8011 x 3.0k-B Orifice Assembly 1 1 EACH Thread 8201 D 1 " M8011 x 3.7k-E Orifice Assembly 1 1 EACH 8202D 1 " M8011 x 4.3k-F Orifice Assembly 1 1 EACH 8203D 1 " M8011 x 5.5k-F Orifice Assembly 1 1 EACH 11/4" M8011 821 OD 1 t/a" M8011 x 3/8" Orifice Assembly 1 1 EACH Thread 8211 D 1 t/a" M8011 x 7/16" Orifice Assembly 1 1 EACH 8212D 11/a" M8011 x'/z" Orifice Assembly 1 1 EACH 8213D 1 t/a" M8011 x 17/32'' Orifice Assembly 1 1 EACH 8214D 1 t/a" M8011 x 5/8" ELO Orifice Assembly 1 1 EACH 11/2" M8011 8220D 11/2" M8011 (THD) x 3/8" Orifice Assembly 1 1 EACH Thread 8221 D 1t/2" M8011 (THD) x 7/16" Orifice Assembly 1 1 EACH 8222D 1 t/z" M8011 (THD) x t/z" Orifice Assembly 1 1 EACH 8223D 11/2" M8011 (THD) x 17/32" Orifice Assembly 1 1 EACH 8224D 11/2" M8011 (THD) x 5/8" ELO Orifice Assembly 1 1 EACH 11/2" M8011 8225D 11/2" M8011 (THD x GRV) x 3/8" Orifice Assembly 1 1 EACH E Thread x 8226D 1t/2" M8011 (THD x GRV) x 7/16" Orifice Assembly 1 1 EACH Groove 8227D 1 t/z" M8011 (THD x GRV) x t/z" Orifice Assembly 1 1 EACH 8228D 11/2" M8011 (THD x GRV) x 17/32" Orifice Assembly 1 1 EACH S& 8229D 11/2" M8011 (THD x GRV) x 5/8" ELO Orifice Assembly 1 1 EACH 11/2" M8011 8230D 11/2'' M8011 (GRV) x 3/8" Orifice Assembly 1 1 EACH 8231 D 11/2'' M8011 (GRV) x 7/16" Orifice Assembly 1 1 EACH &kGroove 8232D 11/2" M8011 (GRV) x 1/2" Orifice Assembly 1 1 EACH 8233D 11/2" M8011 (GRV) x 17/32" Orifice Assembly 1 1 EACH 8234D 11/2" M8011 (GRV) x 5/8" ELO Orifice Assembly 1 1 EACH 2" M8011 8240D 2" M8011 (THD) x 3/8" Orifice Assembly 1 1 EACH Thread 8241 D 2" M8011 (THD) x 7/16" Orifice Assembly 1 1 EACH 8242D 2" M8011 (THD) x 1/2" Orifice Assembly 1 1 EACH 8243D 2" M8011 (THD) x 17/32" Orifice Assembly 1 1 EACH 8244D 2" M8011 (THD) x 5/8" ELO Orifice Assembly 1 1 EACH 16 Product Information V008.0 i AG Item ID Item Description Item Class Master Carton Minimum Order Qty. Unit 2" M8011 8245D 2" M8011 (THD x GRV) x 3/8" Orifice Assembly 1 1 EACH Thread x 8246D 2" M8011 (THD x GRV) x �/16" Orifice Assembly 1 1 EACH Groove 8247D 2" M8011 (THD x GRV) x'/2" Orifice Assembly 1 1 EACH 8248D 2" M8011 (THD x GRV) x 17/32" Orifice Assembly 1 1 EACH 8249D 2" M8011 (THD x GRV) x 5/8" ELO Orifice Assembly 1 1 EACH 2" M8011 8250D 2" M8011 (GRV) x 3/8" Orifice Assembly 1 1 EACH - Groove 8251 D 2" M8011 (GRV) x 7/16" Orifice Assembly 1 1 EACH 8252D 2" M8011 (GRV) x'/z" Orifice Assembly 1 1 EACH 82530 2" M8011 (GRV) x'7/32" Orifice Assembly 1 1 EACH 8254D 2" M8011 (GRV) x 5/8" ELO Orifice Assembly 1 1 EACH Model 8000 RESIDENTIAL RISERPACK° Pre Assembled Riser for NFPA 13R Systems Assembly includes: bronze riser body w/ imprinted signage, water flow alarm switch w/ retard, 3'/2" pressure gauge with'/4" 3-way valve, appropriately sized drain valve w/ specific TEST orifice, sight glass option available, non retard flow switch special order W11— 7 AGF Item ID Item Description Item Class Master Carton Minimum Order Qty. Unit 1'/4" M8000 811 OR 1'/4" M8000 x 3/8" Orifice Assembly 1 1 EACH Thread 8111 R 1'/4" M8000 x 7/16" Orifice Assembly 1 1 EACH 911 8112R 1'/4" M8000 x'/z" Orifice Assembly 1 1 EACH 1 8113R 1'/4" M8000 x 17/32" Orifice Assembly 1 1 EACH 8114R 1'/4" M8000 x 5/8" ELO Orifice Assembly 1 1 EACH 1'/2" M8000 8120R 1'/z" M8000 (THD) x 3/8" Orifice Assembly 1 1 EACH Thread OF,,% 8121 R 1'/z" M8000 (THD) x 7/16" Orifice Assembly 1 1 EACH 8122R 1 %2" M8000 (THD) x %2" Orifice Assembly 1 1 EACH 8123R 1'/z" M8000 (THD) x 17/32" Orifice Assembly 1 1 EACH 8124R 1 %2" M8000 (THD) x 5/8" ELO Orifice Assembly 1 1 EACH 11/2" M8000 8125R 1'/2" M8000 (THD x GRV) x 3/8" Orifice Assembly 1 1 EACH Thread x a- 8126R 1'/2" M8000 (THD x GRV) x �/16" Orifice Assembly 1 1 EACH Groove 8127R 1'/2" M8000 (THD x GRV) x'/2" Orifice Assembly 1 1 EACH 8128R 1'/2" M8000 (THD x GRV) x 17/32" Orifice Assembly 1 1 EACH 8129R 1%2" M8000 (THD x GRV) x 5/8" ELO Orifice Assembly 1 1 EACH 1'/2" M8000 8130R 1'h" M8000 (GRV) x 3/8" Orifice Assembly 1 1 EACH Groove 8131 R 1'/2" M8000 (GRV) x 7/16" Orifice Assembly 1 1 EACH 8132R 1'/2" M8000 (GRV) x'h" Orifice Assembly 1 1 EACH 8133R 1'/2" M8000 (GRV) x 17/32" Orifice Assembly 1 1 EACH + 8134R 1'/2" M8000 (GRV) x 5/8" ELO Orifice Assembly 1 1 EACH 2" M8000 8140R 2" M8000 (THD) x 3/8" Orifice Assembly 1 1 EACH Thread M 8141 R 2" M8000 (THD) x �/16" Orifice Assembly 1 1 EACH 8142R 2" M8000 (THD) x'/2" Orifice Assembly 1 1 EACH 8143R 2" M8000 (THD) x 17/32" Orifice Assembly 1 1 EACH 8144R 2" M8000 (THD) x 5/8" ELO Orifice Assembly 1 1 EACH Product Information V008.0 17 AF AGF Item ID Item Description Item Class Master Carton Minimum Order Oty. Unit 2" M8000 8145R 2" M8000 (THD x GRV) x 3/8" Orifice Assembly 1 1 EACH Thread x 8146R 2" M8000 (THD x GRV) x 7/16" Orifice Assembly 1 1 EACH Groove T• 8147R 2" M8000 (THD x GRV) x 1/2" Orifice Assembly 1 1 EACH 8148R 2" M8000 (THD x GRV) x 17/32" Orifice Assembly 1 1 EACH 8149R 2" M8000 (THD x GRV) x 5/8'' ELO Orifice Assembly 1 1 EACH 2" M8000 815OR 2'' M8000 (GRV) x 3/8" Orifice Assembly 1 1 EACH Groove 8151 R 2" M8000 (GRV) x 7/16" Orifice Assembly 1 1 EACH 8152R 2" M8000 (GRV) x 1/2" Orifice Assembly 1 1 EACH 8153R 2" M8000 (GRV) x 17/32" Orifice Assembly 1 1 EACH 8154R 2" M8000 (GRV) x 5/8" ELO Orifice Assembly 1 1 EACH Model 8011 RESIDENTIAL RISERPACK® Pre Assembled Riser for NFPA 13R Systems Requiring Pressure Relief Assembly includes: bronze riser body w/ imprinted signage, water flow alarm switch w/ retard, 31/2" pressure gauge with 1/a" 3-way valve, appropriately sized drain valve w/ specific TEST orifice, pressure relief valve w/ drain trim, sight glass option available, non retard flow switch special order M8011 valves are packaged with a trim kit. The trim kit includes a 175 PSI rated M7000 PRV and drain trim. M7000 valves are also available in PSI ratings of 165, 185, 195, 205, 225, and 250. Note: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. AGF Item ID Item Description Item Class Master Carton Minimum Order Oty. Unit 11/4" M8011 821 OR 1 t/a" M8011 x 3/8'' Orifice Assembly 1 1 EACH Thread 8211 R 1 t/a" M8011 x 7/16'' Orifice Assembly 1 1 EACH t 8212R 1'/a" M8011 x'/2" Orifice Assembly 1 1 EACH 8213R 1 t/a" M8011 x 17/32" Orifice Assembly 1 1 EACH 8214R 1 t/a" M8011 x 5/8" ELO Orifice Assembly 1 1 EACH NY' M8011 8220R 11/2" M8011 (THD) x 3/8" Orifice Assembly 1 1 EACH Thread 8221 R 11/2" M8011 (THD) x 7/16" Orifice Assembly 1 1 EACH 8222R 11/2" M8011 (THD) x 1/2" Orifice Assembly 1 1 EACH 8223R 11/2" M8011 (THD) x 17/32" Orifice Assembly 1 1 EACH 8224R 11/2" M8011 (THD) x 5/8" ELO Orifice Assembly 1 1 EACH 11/2" M8011 8225R 11/2" M8011 (THD x GRV) x 3/8" Orifice Assembly 1 1 EACH Thread x 8226R 11/2" M8011 (THD x GRV) x 7/16" Orifice Assembly 1 1 EACH Groove I 8227R 11/2" M8011 (THD x GRV) x 1/2" Orifice Assembly 1 1 EACH '8228R 11/2" M8011 (THD x GRV) x 17/32" Orifice Assembly 1 1 EACH 8229R 11/2" M8011 (THD x GRV) x 5/8" ELO Orifice Assembly 1 1 EACH 11/2" M8011 8230R 11/2" M8011 (GRV) x 3/8" Orifice Assembly 1 1 EACH Groove 8231 R 11/2" M8011 (GRV) x 7/16" Orifice Assembly 1 1 EACH 8232R 11/2" M8011 (GRV) x 112" Orifice Assembly 1 1 EACH 8233R 11/2" M8011 (GRV) x 17/32" Orifice Assembly 1 1 EACH G 8234R 11/2" M8011 (GRV) x 5/8" ELO Orifice Assembly 1 1 EACH 18 Product Information V008.0 i AGF Item ID Item Description Item Class Master Carton Minimum Order Qty. Unit 2" M8011 8240R 2" M8011 (THD) x 3/8" Orifice Assembly 1 1 EACH Thread 8241 R 2" M8011 (THD) x 7/16" Orifice Assembly 1 1 EACH 8242R 2" M8011 (THD) x 1/2" Orifice Assembly 1 1 EACH +, 8243R 2" M8011 (THD) x 17/32" Orifice Assembly 1 1 EACH C 8244R 2" M8011 (THD) x 5/8" ELO Orifice Assembly 1 1 EACH 2" M8011 8245R 2" M8011 (THD x GRV) x 3/8" Orifice Assembly 1 1 EACH Thread x 8246R 2" M8011 (THD x GRV) x 7/16" Orifice Assembly 1 1 EACH Groove 8247R 2" M8011 (THD x GRV) x 1/2" Orifice Assembly 1 1 EACH ., 8248R 2" M8011 (THD x GRV) x 17/32" Orifice Assembly 1 1 EACH 8249R 2" M8011 (THD x GRV) x 5/8" ELO Orifice Assembly 1 1 EACH 2" M8011 8250R 2" M8011 (GRV) x 3/8" Orifice Assembly 1 1 EACH Groove { 8251 R 2" M8011 (GRV) x 7/16" Orifice Assembly 1 1 EACH 8252R 2" M8011 (GRV) x 1/2" Orifice Assembly 1 1 EACH ., 8253R 2" M8011 (GRV) x 17/32" Orifice Assembly 1 1 EACH G 8254R 2" M8011 (GRV) x 5/8" ELO Orifice Assembly 1 1 EACH Model 8000 COMMERCIAL RISERPACK® Pre Assembled Riser for NFPA 13 Sectional Floor Control Assembly, Cast Bronze 11/411 - 211 Assembly includes: bronze riser body w/ imprinted signage, water flow alarm switch w/ retard, 31/2" pressure gauge with 1/4" 3-way valve, appropriately sized TESTANDRAIN® valve w/ specific TEST orifice, AGF Item ID Item Description Item Class Master Carton Minimum Order Qty. Unit 11/4" M8000 831 OA 11/4" M8000 x 3/8" Orifice Assembly 1 1 EACH Thread 8311A 11/4" M8000 x 7/16" Orifice Assembly 1 1 EACH 8312A 11/4" M8000 x 1/2" Orifice Assembly 1 1 EACH 8313A 11/4" M8000 x 17/32" Orifice Assembly 1 1 EACH 8314A 11/4" M8000 x 5/8" ELO Orifice Assembly 1 1 EACH 11/21, M8000 8320A 11/2" M8000 (THD) x 3/8" Orifice Assembly 1 1 EACH Thread 8321A 11/2" M8000 (THD) x 7/16" Orifice Assembly 1 1 EACH 8322A 11/2" M8000 (THD) x 1/2" Orifice Assembly 1 1 EACH 8323A 11/2" M8000 (THD) x 17/32" Orifice Assembly 1 1 EACH 8324A 11h" M8000 (THD) x 5/8" ELO Orifice Assembly 1 1 EACH 11/2" M8000 8325A 11/2" M8000 (THD x GRV) x 3/8" Orifice Assembly 1 1 EACH Thread x 8326A 11/2" M8000 (THD x GRV) x 7/16" Orifice Assembly 1 1 EACH Groove 8327A 11/2" M8000 (THD x GRV) x 1/2" Orifice Assembly 1 1 EACH 8328A 11h" M8000 (THD x GRV) x 17/32" Orifice Assembly 1 1 EACH ' 8329A 11/z M8000 (THD x GRV) x 5/6 ELO Orifice Assembly 1 1 EACH 11/2" M8000 8330A 11/2" M8000 (GRV) x 3/8" Orifice Assembly 1 1 EACH Groove r'. 8331A 11h" M8000 (GRV) x 7/16" Orifice Assembly 1 1 EACH 8332A 11/2" M8000 (GRV) x 1/2" Orifice Assembly 1 1 EACH 8333A 11/2" M8000 (GRV) x 17/32" Orifice Assembly 1 1 EACH 8334A 11/2" M8000 (GRV) x 5/8" ELO Orifice Assembly 1 1 EACH Product Information V008.0 19 AF AGF Item ID Item Description Item Class Master Carton Minimum Order Oty. Unit 2" M8000 8340A 2" M8000 (THD) x 3/8" Orifice Assembly 1 1 EACH Thread 8341A 2" M8000 (THD) x 7/16" Orifice Assembly 1 1 EACH 8342A 2" M8000 (THD) x 1/2" Orifice Assembly 1 1 EACH I , 8343A 2" M8000 (THD) x 17/32" Orifice Assembly 1 1 EACH 8344A 2" M8000 (THD) x 5/8" ELO Orifice Assembly 1 1 EACH 2" M8000 8345A 2" M8000 (THD x GRV) x 3/8" Orifice Assembly 1 1 EACH Thread x 8346A 2" M8000 (THD x GRV) x 7/16" Orifice Assembly 1 1 EACH Groove. 8347A 2" M8000 (THD x GRV) x 1/2" Orifice Assembly 1 1 EACH f 8348A 2" M8000 (THD x GRV) x 17/32" Orifice Assembly 1 1 EACH 8349A 2" M8000 (THD x GRV) x 5/8" ELO Orifice Assembly 1 1 EACH 2" M8000 8350A 2" M8000 (GRV) x 3/8" Orifice Assembly 1 1 EACH Groove lq, 8351A 2" M8000 (GRV) x 7/16" Orifice Assembly 1 1 EACH 8352A 2" M8000 (GRV) x 1/2" Orifice Assembly 1 1 EACH 4 4 8353A 2" M8000 (GRV) x 17/32" Orifice Assembly 1 1 EACH 8354A 2" M8000 (GRV) x 5/8" ELO Orifice Assembly 1 1 EACH Model 8011 COMMERCIAL RISERPACK® Pre Assembled Riser for NFPA 13 Sectional Floor Control Assembly Requiring Pressure Relief, Cast Bronze 11/4"- 2" Assembly includes: bronze riser body w/ imprinted signage, water flow alarm switch w/ retard, 31/2" pressure gauge with 3-way valve, appropriately sized TESTANDRAIN® valve w/ specific TEST orifice, pressure relief valve w/ drain trim. M8011 valves are packaged with a trim kit. The trim kit includes a 175 PSI rated M7000 PRV and drain trim. M7000 valves are also available in PSI ratings of 165, 185, 195, 205, 225, and 250. Note: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. AGF Item ID Item Description Item Class Master Carton Minimum Order Oty. Unit 11/4" M8011 8410A 11/4" M8011 (THD) x 3/8" Orifice Assembly 1 1 EACH Thread I 8411A 11/4" M8011 (THD) x 7/16" Orifice Assembly 1 1 EACH 8412A 11/4" M8011 (THD) x 1/2" Orifice Assembly 1 1 EACH u 8413A 11/4" M8011 (THD) x 17/32" Orifice Assembly 1 1 EACH +� 8414A 11/4" M8011 (THD) x 5/8" ELO Orifice Assembly 1 1 EACH 11/2" M8011 8420A 11/2" M8011 (THD) x 3/8" Orifice Assembly 1 1 EACH Thread 8421A 1%2" M8011 (THD) x 7/16" Orifice Assembly 1 1 EACH 8422A 11/2" M8011 (THD) x 1/2" Orifice Assembly 1 1 EACH 8423A 11/2" M8011 (THD) x 17/32" Orifice Assembly 1 1 EACH 8424A 11/2" M8011 (THD) x 5/8" ELO Orifice Assembly 1 1 EACH 11/2" M8011 8425A 11/2" M8011 (THD x GRV) x 3/8" Orifice Assembly 1 1 EACH Thread x 8426A 1%2" M8011 (THD x GRV) x 7/16" Orifice Assembly 1 1 EACH Groove 8427A 11/2" M8011 (THD x GRV) x 1/2" Orifice Assembly 1 1 EACH t" 8428A 1%2" M8011 (THD x GRV) x 17/32" Orifice Assembly 1 1 EACH 8429A 11h" M8011 (THD x GRV) x 5/8" ELO Orifice Assembly 1 1 EACH 20 Product Information V008.0 AGF Item ID Item Description Item Class Master Carton Minimum Order Oty. Unit 11/2" M8011 8430A 1'/2" M8011 (GRV) x 3/8" Orifice Assembly 1 1 EACH Groove 8431A 1'/2" M8011 (GRV) x 7/16" Orifice Assembly 1 1 EACH 8432A 11/2" M8011 (GRV) x 1/2" Orifice Assembly 1 1 EACH 8433A 1'/2" M8011 (GRV) x 17/32" Orifice Assembly 1 1 EACH 8434A 11/2" M8011 (GRV) x 5/8" ELO Orifice Assembly 1 1 EACH 2" M8011 8440A 2" M8011 (THD) x 3/8" Orifice Assembly 1 1 EACH Thread 8441A 2" M8011 (THD) x 7/16" Orifice Assembly 1 1 EACH 8442A 2" M8011 (THD) x 1/2" Orifice Assembly 1 1 EACH IW-1 8443A 2" M8011 (THD) x 17/32" Orifice Assembly 1 1 EACH 8444A 2" M8011 (THD) x 5/8" ELO Orifice Assembly 1 1 EACH 2" M8011 8445A 2" M8011 (THD x GRV) x 3/8'' Orifice Assembly 1 1 EACH Thread x 8446A 2" M8011 (THD x GRV) x 7/1s" Orifice Assembly 1 1 EACH Groove 8447A 2" M8011 (THD x GRV) x 1/2" Orifice Assembly 1 1 EACH 8448A 2" M8011 (THD x GRV) x 17/32" Orifice Assembly 1 1 EACH 8449A 2" M8011 (THD x GRV) x 5/8" ELO Orifice Assembly 1 1 EACH 2" M8011 8450A 2" M8011 (GRV) x 3/8" Orifice Assembly 1 1 EACH Groove 8451 A 2" M8011 (GRV) x 7/16" Orifice Assembly 1 1 EACH 8452A 2" M8011 (GRV) x 1/2" Orifice Assembly 1 1 EACH 8453A 2" M8011 (GRV) x 17/32" Orifice Assembly 1 1 EACH 8454A 2" M8011 (GRV) x 5/8" ELO Orifice Assembly 1 1 EACH Model 8000 COMMERCIAL RISERPACK® Pre Assembled Riser for NFPA 13 Sectional Floor Control Assembly, Fabricated Schedule 40 Steel 21/211- 611 Assembly includes: schedule 40 fabricated steel body w/ 3 mil powder coat red finish and grooved ends, water flow alarm switch w/ retard, 31/2" pressure gauge with 3-way valve, appropriately sized TESTANDRAIN° valve w/ specific TEST orifice. AGF Item ID Item Description Item Master Carton MinimumClass Order Oty. Unit 21/2" M8000 8360A 2'/2" M8000 x 3/8" Orifice Assembly 1 1 EACH (r 8361 A 2%2" M8000 x 7/16" Orifice Assembly 1 1 EACH 8362A 21/2" M8000 x'/2" Orifice Assembly 1 1 EACH ; aY 8363A 21/2" M8000 x 17/32" Orifice Assembly 1 1 EACH ..r 8364A 2'/2" M8000 x 5/8" ELO Orifice Assembly 1 1 EACH 8365A 21/2" M8000 x 3/a" ESFR Orifice Assembly 1 1 EACH 3" M8000 8370A 3" M8000 x 3/8" Orifice Assembly 1 1 EACH �Y 8371A 3" M8000 x 7/16" Orifice Assembly 1 1 EACH 8372A 3" M8000 x 1/2" Orifice Assembly 1 1 EACH (� 8373A 3" M8000 x 17/32" Orifice Assembly 1 1 EACH 8374A 3" M8000 x 5/8" ELO Orifice Assembly 1 1 EACH 8375A 3" M8000 x 3/a" ESFR Orifice Assembly 1 1 EACH Product Information V008.0 21 AF AGF Item ID Item Description Item Master Carton Minimum Order Oty. UnitClass 4" M8000 8380A 4" M8000 x 3/8" Orifice Assembly 1 1 EACH 8381A 4" M8000 x 7/16" Orifice Assembly 1 1 EACH 8382A 4" M8000 x t/2" Orifice Assembly 1 1 EACH 8383A 4" M8000 x 17/32" Orifice Assembly 1 1 EACH 8384A 4" M8000 x 5/8" ELO Orifice Assembly 1 1 EACH Utilizes M2500 Groove x 8385A 4'' M8000 x 3/4" ESFR Orifice Assembly 1 1 EACH GrooveTESTANDRAIN° 8386A 4" M8000 x K25 Orifice Assembly 1 1 EACH 6" M8000 8390A 6" M8000 x 3/8" Orifice Assembly 1 1 EACH 8391A 6" M8000 x 7/16" Orifice Assembly 1 1 EACH 8392A 6" M8000 x t/2" Orifice Assembly 1 1 EACH 8393A 6" M8000 x 17/32" Orifice Assembly 1 1 EACH 8394A 6" M8000 x 5/8" ELO Orifice Assembly 1 1 EACH Utilizes M2500 Groove x 8395A 6'' M8000 x 3/4" ESFR Orifice Assembly 1 1 EACH GrooveTESTANDRAIN® 8396A 6" M8000 x K25 Orifice Assembly 1 1 EACH Model 8011 COMMERCIAL RISERPACK® Pre Assembled Riser for NFPA 13 Sectional Floor Control Assembly Requiring Pressure Relief, Fabricated Schedule 40 Steel 21/2" - 6" Assembly includes: schedule 40 fabricated steel body w/ 3 mil powder coat red finish and grooved ends, water flow alarm switch w/ retard, 31/2" pressure gauge with 3-way valve, appropriately sized TESTANDRAIN° valve w/ specific TEST orifice, pressure relief valve w/ drain trim. M8011 valves are packaged with a trim kit. The trim kit includes a 175 PSI rated M7000 PRV and drain trim. M7000 valves are also available in PSI ratings of 165, 185, 195, 205, 225, and 250. 'Note: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. AGF Item ID Item Description Item Master Carton MinimumClass Order Oty. Unit 21/2" M8011 8460A 2t/z" M8011 x 3/8" Orifice Assembly 1 1 EACH 8461A 2th" M8011 x 7/16" Orifice Assembly 1 1 EACH 8462A 2'/2" M8011 x 1/2" Orifice Assembly 1 1 EACH 8463A 2t/2" M8011 x 17/32" Orifice Assembly 1 1 EACH 8464A 21/2" M8011 x 5/8" ELO Orifice Assembly 1 1 EACH 8465A 2t/2" M8011 x 3/4" ESFR Orifice Assembly 1 1 EACH 3" M8011 8470A 3" M8011 x 3/8" Orifice Assembly 1 1 EACH 8471A 3" M8011 x 7/16" Orifice Assembly 1 1 EACH 8472A 3" M8011 x 1/2" Orifice Assembly 1 1 EACH 8473A 3" M8011 x 17/32" Orifice Assembly 1 1 EACH 8474A 3" M8011 x 5/8" ELO Orifice Assembly 1 1 EACH 8475A 3'' M8011 x 3/" ESFR Orifice Assembly 1 1 EACH 22 Product Information V008.0 AGF Item ID Item Description Item Class Master Carton MinimumUnit Order Oty. 4" M8011 8480A 4" M8011 x 3/8" Orifice Assembly 1 1 EACH 8481A 4" M8011 x 7/16" Orifice Assembly 1 1 EACH 8482A 4" M8011 x 1/2" Orifice Assembly 1 1 EACH L 8483A 4" M8011 x 17/32" Orifice Assembly 1 1 EACH 8484A 4" M8011 x 5/8" ELO Orifice Assembly 1 1 EACH Utilizes M2500 Groove x 8485A 4" M8011 x 3/a" ESFR Orifice Assembly 1 1 EACH GrooveTESTANDRAIN° 8486A 4" M8011 x K25 Orifice Assembly 1 1 EACH 6" M8011 8490A 6" M8011 x 3/8" Orifice Assembly 1 1 EACH 8491A 6" M8011 x 7/16" Orifice Assembly 1 1 EACH 8492A 6" M8011 x 1/2" Orifice Assembly 1 1 EACH i8493A 6" M8011 x 17/32" Orifice Assembly 1 1 EACH 8494A 6" M8011 x 5/8" ELO Orifice Assembly 1 1 EACH Utilizes M2500 Groove x 8495A 6" M8011 x 3/a" ESFR Orifice Assembly 1 1 EACH GrooveTESTANDRAW 8496A 6" M8011 x K25 Orifice Assembly 1 1 EACH Model 6000 and 6100 Center of Tile System Fittings The AGF Center of Tile fittings are designed to provide adjustability in the final piping connection between a water supply line and a wet system fire sprinkler head. This adjustability permits fast and easy placement of the sprinkler head exactly where it needs to go in any type or style of ceiling system or treatment including Drop, Slat, Cloud, Tin and many other innovative architectural designs. By rotating any combination of two 6000 series offset fittings to the desired position, a sprinkler head can be placed at any point within a 12" diameter from the center of the first fitting connection. By rotating any one 6000 series offset fitting to the desired posi- tion, a sprinkler head can be placed at any point on the perimeter of a 6" diameter. Center of Tile fittings are easy to install, and do not require extra hangers, ceiling T-bar brackets, ceiling grids, or special tools. Pre- cise sprinkler head placement can be accomplished in half the normal time with reduction in material cost. 610013 6000B 6000C 6000D 6000E 6000F AGF Item ID Item Description Minimum Order Oty. Unit Models 6000 and 6000B 1 " Female IPS x 1 " Plain End; 2" Length 1 EACH 6100 6000C 1 " Plain End Socket x 1 " Female IPS; 2" Length 1 EACH 6000D 1 " Plain End Socket x 1/2'' Female IPS; 2'' Length x 2" Length 1 EACH 6000E 1 " Female IPS x 1 " Female IPS; 2" Length 1 EACH - 6000F 1 " Female IPS x'/2" Female IPS; 2" Length x 2" Length 1 EACH 610013 1 " Female IPS x 1 " Plain End Elbow 1 EACH Terms and Conditions: All orders must be received by AGF in a written format transmitted to AGF via fax (610-240-4906) or e-mail (orders@testandrain.com). No order will be processed unless prices listed meet current published prices. Freight allowance for domestic shipment is $5,000.00 utilizing AGF shipping vendors. Stipulations of alternate shipping vendors may result in additional surcharges. Minimum order quantities must meet those listed on published Product Information. No returns will be accepted without an AGF Manufacturing Inc. Return Goods Authorization (RGA) number. AGF does not accept customer issued debit memos. Product Information V008.0 23 IOASHCROFT Type 1005P, XUL Fire Protection Sprinkler Service Gauge FEATURES • Underwriters Laboratory listed and Factory Mutual approved • Corrosion -resistant ABS case • Heat -resistant po/ycarbonate push - in window • Patented PowerFlex- movement with polyester segment • True Zero- indication, a unique safety feature Ashcroft° fire protection sprinkler gauges are Underwriters Laboratory listed and Factory Mutual approved for fire protection sprinkler service. The case material on Type 1005P, XUL gauges is ABS. The 0-300 psi pressure range is used on "wet' systems where water is available to the sprinkler heads. The 0-80 retard to 250 psi pressure range is used on dry systems where the lines are filled with air pressure until system activation. The patented PowerFlex'" movement with polyester segment is designed to provide unequalled shock and vibration resistance resulting in superior perform- ance and extended gauge life. True Zero- indication, a standard fea- ture on these gauges, reduces the poten- tial risk of installing a damaged gauge on your equipment. HOW TO ORDER (Typical example) 35 W Dial Size: 31/2"— Movement: Paten Case Type Numb( Case Material: Al Socket Material: Connection Size/1 Listing: UL listed, Range: 0/300 psi PRODUCT SPECIFICATIONS Ashcroft° Model No.: 1005P, XUL Accuracy: ASME B 40.100 Grade B (±3-2-3% of span) Size: Th- Case: ABS (Polycarbonate blend)'/2 Ring: None Window: Polycarbonate, push -in Dial: Black figures on white back- ground Pointer: Black, aluminum Bourdon tube: "C" shaped bronze Movement: Patented PowerFlexrMwith polyester segment Socket: Brass Restrictor: None Connection: A NPT lower Ranges: 0-300 psi (water) 0-80 retard to 250 psi (air) Operating temperature: -40oF to 150°F; -40oC to 65°C UL 393 Listed, UL of Canada Listed and FM approved. Equivalent (single or dual scale) metric scales are available OPTIONAL FEATURES Customized dials Other UL listed ranges on application 1005 P H 02L XUL 300# ISO 9001 All specifications are subject to change without notice. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA REGISTERED FIRM All sales subject to standard terms and conditions. Tel: 203-378-8281 • Fax: 203-385-0408 BULLETIN CSG-3 0 Ashcroft Inc. 2011 07/11 email: info@ashcroft.com • www.ashcroft.com ►ASHCROFT Type 1005P, XUL Fire Protection Sprinkler Service Gauge DIMENSIONS SIZElrYPE A B C D E G 3'/- 1005P, XUL 3.70 1.14 2.72 3.61 0.47 0.56 (94) (29) (69) (92) (11.9) (14.2) ISO 9001 All specifications are subject to change without notice. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA REGISTERED FIRM All sales subject to standard terms and conditions. Tel: 203-378-8281 • Fax: 203-385-0408 BULLETIN CSG-3 0 Ashcroft Inc. 2011 07/11 email: info@ashcroft.com • www.ashcroft.com Job Name . Job Location For Commercial and Industrial Applications Contractor Approval Engineer Contractor's P.O. No. Approval Representative — Series FBV-3C, FBVS-3C 2-Piece, Full Port, Brass Ball Valves Sizes: 1/4" - 4" (8-100mm) Series FBV-30 2-piece, full pat, brass ball valves are used in com- mercial and industrial applications for a hit range of liquids and gases. They feature a bottom -loaded blowout proof stem, virgin PTFE seats, thrust washer, and adjustable stem packing gland stem packing nut, chrome plated brass ball, brass adapter, and steel handle. Features • Certifed to NSF/ANSI standard 61/5 • CSA approved threaded valves only 3" (15 - 80mm) t UL/FM approved lfxeaded valves %' - 2' (15 - 50mm) • UL Listed solder valves'/d' - 2" (15 - 50mm) • Fluorocarbon elastomer stem 0-ring prevents stem leaks • Adjustable stem packing gland • PTFE stem packing seal, thrust washer, and seals • Bottom loaded blowout proof stem • Machined chrome plated braes ball • Valves comply to MSSSP-110 standard Models FBV-3Q'/i -4" (8-100mm) with threaded convections FBVS-3Q'/P-3' (15- 80mm) with solder connections FBV-3C-TH: V,' -1- (15-25mm) tee handle with threaded connec- gons FBVS-3C-TH:1h'-1- (15-25mm) tee handle wN1 solder connections Pressure - Temperature Temperature Flange: 40" to 400`F h40'C In 204"C) Pressure Ratings FBV-3C:'/C -2' (8-50mm) 600psi (41 barn WOG, norsohock 150psi (10.3 bad WSP 2Vi-a-(65-t00mm) 4000 (27.5 bar) WOG. non -snook 125psi (8.6 bat) WSP FBVs3C:'h'- 2" (15-60m m) 600pst (41 bar) WOG, rwnshock 150PSI (10.3 bad W&P 21/2" - 3" (65- 30m r) 400pa (27.5 bar) WOG. non -shock 125psi (8.6 bar) WSP 'This valve Is designed to be soft soldered into lines without disassembly, using a low temperature solder to 420"F (216"C). Higher temperature solders may damage the seat material. NOTE: Apply heat with the game directed AWAY from the center of the valve body. Excessive heat can harm the seats. After soldering, the packing nut may have to be tightened. W Fevsac Fav3o-TH Approvals '/i -3' (8 -80m" FBV-3C Vol-1' (15 - 25mml FBV-BC-TH Oertfied w NSF/ANSI standard 61/8' '/,'-3" (15 -80mm) FBVS3C '/z-1"h5-25mm)FMV G-TH Certified to NSF/ANSI standard 61/8' 'Ocneagc cold water at 73-F (23-0 M2'-2'(15-5(km1)FBV-33 ULIFM approved 4L 'h"-1' (15- 25mm) FBOL-3C-TH mow^ 'h"-2'(15- 50mm) FBVS-30 UL Listed O M<'-1"(15-25mm)FBVS-3GTH 4L Gas Approvals (Threaded Valves Only) 114"-3/e" (8-10111 ASME B16.33, CSA COO 'hpeg, 5psg, (14, 34 kPa) W -40 r to 125-F P-4M W 520Q 2"(15- 50mn) ASME B16.33 CSA e 'h Psig, 5psg, and 125psg (14,34 and 862 Job) ® A(EF to 125-F (-40'C to 52Cq 21/1' -3" (65 -80mm) ASME B16.38, CSA $�W Vx peg, bluest, and 125psig (14,34 and 852 kPa) @ -40"F to 125`E h40O to 52xq Specifications Appeae dvalves shall be 2-piece fW port design constructed of a forged Gass body and end scepter. Seats and stem packing shall bs virgin FIFE. Stan shall be bottom loaded, bhwme proof design with fluo- mcarbon elastomer 0-ring to prevent stem leaks. Valve shall have chrome Plated Gass baR and adjustable padding gland. Threaded valves'/z" -3• (shall be CSA approved to'h, 5, and 125psg (14.34 and 862 kPa), UV FM approved and ceMw to NSF/ANSI standard 61/8. Seder valves to be UL listed and cagfied W NSFANSI standard 61/8. Make sizes'/: -2- (B-SOmm) shad be rated to WOO (41 bar) WOG non -shock and 1501d (10.3 bard WSP. Valve sizes 2'h'- h 65-100mm1 threaded. shad be Regulator Company Sens Wells WxId slwOolae N 0 S. (slanae lags am merit ae aaW e. antl ae pm ImlarelaelMYay Fan"weemoo.c.k gasamNut Wads Ten[2g 5°tri¢ Wa16 reserves lore 4a4mdaleaa moSlypmdW M-sign, mrshudkn, sAaotkalon4 amaEfiakwAR all p'rr 2e ennwAhM NWIM9aMomiAanian to mak9 Flu'M1 eM1anAaaaM motlRll'alYeon Watl5 pN0uN penw5yrc51elequmN/Ski, Boom) solder and be rated to 400psi (27.5 250 (B.6 W WSP. Vave shall he a Watts =RV3C (Breadec) or FBV&-3C (solder). WWATM Materials FBV3C M-B FBI A. Handle Nut Zinc plated carbon steel B. Handle Assembly One plated cannon steel with vinyl insulator C. Packing Nut Brass D. am Packing Virgin P`TE E. 0-ring Fluorocarbon elactomer IFi F. Thrust Washer Virgin PTFE G. Stem Machined Brass H. Tag Cardboard. Mylar waled both sides I. Body Forged Brass J. Sea6 Virgin P-rFE K. Ball Chrome plated brass L. Adapter Forged Brass Dimensions - Weights H' - l C LJ L L1 J, FBV-3C FBVS-3C Temperature - Pressure bar 41.3 e 34.5 Y 27.6 It, 20.7 Y 3 13.0 6.9 3.4 6 Working Temperature 'See applicable note on reverse side for solder end valves with regards to pressure/ temperature rating. r m c ova H M. mn Po A eve h I ran N L mm L1 A mm as 7a 8 1'1.5e 46 3r/a 87 - 'h 12.9 IV, 45 0.4 0.2 36 10 1' a 48 31Aa 87 - 'h 12.9 1% 45 0.4 0.2 'h 15 I'Vs 46 31e 87 314s 87 N 12.9 1,%. 50 2'As 52 0.4 0.2 J 20 2'/ 57 4 101 4 101 s/4 19.2 2M. 59 TFa fib 0.8 0.3 1 25 21h 67 4A 108 4% IN 1 25.5 211 72 3% 83 1.2 0.5 11/1 32 2'i5a 71 4Y4 IN 411, 108 1% 31.9 As 81 VYI. 94 1.8 0.8 Vh 40 Via 80 51/4 131 SMs 135 1Y Suit 3'h 88 4% IN 2.6 1.2 2 50 31h 89 6 153 6 153 2 50.9 4ib 1p5 5sha 135 3.7 1.7 21h fi5 4Yn 104 749 1 W ]i% 188 2'h 63.8 5aAs 134 8'h 16B 7.1 1.2 3 80 4h 114 ] 4 1B] 7yi 19] 1 3 76.3 1 61/js 154 1 7% 185 11.3 4.7 4 1W 53b 136 1 9% 245 1 - 4 101.8 1 Pra 189 177 8.0 FBV-3C-TH and Milli m mm c a nun x h nxn xr mmr w 1 mmr In. mm L1 tt mm fik. 'A 15 114a 39.6 3'A 79.3 31A 79.3 M 129 PYis 50 2Ma 52 0.4 02 4 20 2 50.9 33b 05.7 3% 85.7 1/ My 2%s 59 TVie 60 0.8 0.3 1 25 21A 53.9 3sA a5.7 31A mj 1 25.5 2u/v M 3'A 83 1 .2 0.5 \1WAT M A Watts Water TeCono/ogies Company ESFSV-3C 0935 CE T UBIi 815 Chealnut St.. No. Andover, 6W 01&5-So98, www.walla.com Common; M35 MM, Sanwa Pa. BuIngton. OM. L]L 5117, w .waxscanaaa.ca ® 2009 Wads Close Tyco Fire Products Features and Benefits • Ready to Install • No Power Machine for Repair • Eliminates Searching for Materials • Eliminates Potential Leaks • Eliminates Labor of Fabrication • Classic Look of a Professional Job • Net Weight Only 6.25 lbs. • Overall Length 24" (615 mm) • Turning Radius 2.5" (64 mm) General Description The DD-1 Condensate Drain is a pre -man- ufactured drum drip for installation in Dry - Pipe, Deluge and Pre -Action Automatic Sprinkler Systems. The DD-1 Condensate Drain is made from Electric -Resistance -Welded Carbon and Alloy Steel Mechanical Tubing, ASTM A513. After the machining process is complete, the 1 " male outlets shall have a wall thickness greater than or equal to 0.133 inches and an O.D. of 1.315 inches. Other drains are usually constructed from various parts that must be assembled at the time of installation. There is no comparison in the quality and look of the DD-1 Condensate Drain and it is quick and easy to install. MODEL DD-1 WiliagTM Condensate Drain Technical Data • Volume: 0.1875 gallons • Standard Working Pressure of 175 psi • Valve type and manufacturer may vary • Length: 24" (615 mm) • Turning radius 2.5" (64 mm) • Shipping weight: 6.26 pounds • U.S. Patent number 6,102,066 (Always refer to Technical Data Sheet for complete description of all Listing criteria, design parameters, installation instructions, care and maintenance guidelines, and our Limited Warranty.) Close The WiliagTM Condensate Drain includes: • One condensate barrel • Two 1 " shut off valves (valve manufacturer may vary) • One 1 " plug Contact your local distributor for availability. Model DD-1: Specify: Model DD-1 Condensate Drain P/N 52-380-1-001 Traditional Field Generated Drum -Drip tgL:17 Fire Products Tyco Fire Products Technical Services Ph:800-791-9312 Fax:800-791-5500 Wiliag is a registered trademark of The Wiliag Company. Tyco is a registered trademark of Tyco and/or its affiliates in the United States and/or WN/W, Tyc o - F i re. co m other countries. All other brand names, product names, or trademarks belong to their respective holders. Bulletin 204 Rev. V R liabile Sprinkler Emergency Cabinets • Model A4 Designed to carry an emergency supply of sprinklers and a sprinkler wrench. Made of light weight steel with holes for mounting. These compact cabinets are fin- ished in attractive red enamel and are furnished with knockouts to accommodate either 1/2' or 3/4" sprinkler threads. The Model A4 Cabinets are available in the fol- lowing sizes: • 3 Capacity - For residential sprinklers in NFPA 13D and 13R systems 5" high x 7%6" long x 2X" deep. Locate wrench separately. • 6 Capacity Standard - For y" and X" NPT standard and large orifice sprinklers. 5" high x 14" long x 2%" deep. • 6 Capacity Large - For ESFR, XLO and VELO Sprinklers. 6/" high x 14" long x 3 8" deep. • 12 Capacity Standard - For %" and X" NPT standard and large orifice sprinklers. 5" high x 14" long x 4" deep. • Model A3 Model A3 Cabinets are designed to carry an emergency supply of decorative type sprinklers and an installation wrench. They are able to accommodate 12 Reliable Models G Recessed, G1, G4, G4FR, ZX or Model B Flush Sprinklers, and up to 6 sprinklers with a 1" adjust- able inlet. Installation Data: Size of Cabinet: 161%6" long x 14%" high x 3%6" deep. Size of Mounting Holes: % diameter. Spacing of Mounting Holes: 13%" length - 11" height. Ordering Information When ordering, specify Model (A4 or A3) and cabinet capacity size and type (Standard or Large). Sprinklers and sprinkler wrenches are to be ordered separately. Sprinkler Escutcheons These escutcheons enhance the appearance of instal- lations by covering exposed fittings of automatic sprin- kler systems that are visible beyond finished ceilings and walls. Furnished to accommodate NPT male pipe threads, escutcheons are held firmly in place by the sprinklers. The finishes provided are decorative and in- tended for indoor use. *Sprinkler Emergency Cabinets *Sprinkler Escutcheons Model A4 3 Capacity Residential Model A4 6 Capacity Standard To; ril Ig 1_q 19 Model A4 6 Capacity Large 12 Capacity Standard UD c m N O m 0 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Approvals There are no UL Listings or FM Approvals associated with the Models A, B, and C one piece escutcheons or the Model HB two piece escutcheon. They may be used with any Reliable Sprinkler with the exception of re- cessed sprinklers which are listed together with their re- spective escutcheons. Refer to the appropriate technical bulletins for this information. • Model B - One Piece Available in steel with satin chrome, bright chrome and brass plated and white painted finishes. Inner fingers grip tightly to the sprinkler. Also available for 10mm sprinklers. Diameter: 21/8"; Depth: 1116"; /" NPT. • Model C - One Piece Available in steel with satin chrome, bright chrome and brass plated and white painted finishes. Inner fingers grip tightly to the sprinkler. Also available for 10mm sprinklers Diameter: 2%"; Depth: Y8"; 1/2" NPT. Model HB - Two Piece Telescoping design permits up to 1" adjustment to compensate for variations in the distance that pipe couplings extend below ceilings. Made of steel and available in brass, chrome, satin nickel and off-white finishes. Diameter: 3/"; Depth: 2" Min, 3" Max; 1/2" and 3/4" NPT. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Rill! able (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address ® Recycled Paper Revision lines indicate updated or new data. PG. Printed in U.S.A. 12/07 P/N 9999970035 Bulletin 135 April 2021 Rel ® Model F1 Res Series Glass Bulb Residential Sprinklers cULus Listed Features • cULus Listed Residential Sprinklers • Available in pendent and horizontal sidewall orientations • Decorative finishes available, including recessed escutcheons and conical concealed cover plates Product Description Model F1 Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The F1 Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model F1 Res Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model F1 Res residential sprinklers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA 13D applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this Bulletin. For NFPA 13 applications, Residential Sprinkler Summary Important Note: Model D wrench and Model GFR2 wrench are no longer compatible with this product. Model W2 (non - recessed) and Model W4 (recessed, concealed) are required. fi the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/ min), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model F1 Res Series sprinklers are listed for use in wet systems only. Sprinkler Model Sprinkler Identification Number (SIN) Orientation K-Factor gpm/psi112 (Ipm/bar'/2) Thread Size NPT or ISO7-1 Installation Options Max. Coverage Area ft x ft (m x m) F1 Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x16 (4.9 x 4.9) F1 Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1 Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1 Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1 Res30 CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed 14 x 14 (4.3 x 4.3) F1 Res49 CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed 20 x 20 (6.1 x 6.1) F1 Res58 CCP R3513 Pendent 5.8(84) 112 Conical Concealed 20 x 20 (6.1 x 6.1) F1 Res76 CCP R7618 Pendent 7.6(109) 3/4 Conical Concealed 20 x 20 (6.1 x 6.1) F1 Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20 (4.9 x 6.1) F1 Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20 (4.9 x 6.1) F1 Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20 (4.9 x 6.1) F1 Res 58 HSWX RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26 (4.3 x 7.9) Note: Please note SIN difference between F1 Res58 HSW (R3533) and F1 Res58 HSWX (RA3533). www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or ISO7-1 R1/2 Sensitivity Nominal K-Factor: 3.0 (43 metric) Fast -response Max. Working Pressure: 175 psi (12 bar) Temperature Ratings 155°F(68°C) Material Specifications 175°F (79°C) Thermal Sensor: 3 mm glass bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed" Sealing Assembly: Nickel Alloy with PTFE Sprinkler Wrenches Load Screw: Bronze Alloy Model W2 Deflector: Bronze Alloy Model W4 (Recessed) *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. ii Model F1 Res30 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) DIA. Face of fitting 1-15/16' to finished (49mm) DIA. ceiling 1/2" (13mm) Threads +/- 1/4" (6mm) Wrench Flat 'VH Sealing Assembly 2 1/4" MStll1 FOM 09 Glass Bulb (57mm) I 1-3/4" (44mm) +/- Load Screw 1/4" (6mm) Deflector 1-1/4" (32mm) 2 7/8" (72mm) DIA. Components Dimensions F2 & FV Recessed Escutcheon Installation Model F1 Res30 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems0) Maximum Coverage Area (2) ft. x ft.(m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 8 (30) 7.0 (0.48) 1 to 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3) 10 (38) 11.0 (0.76) 15 x 15 (4.6 x 4.6) 12 (45) 16.0 (1.1) 16 x 16 (4.9 x 4.9) 13 (49) 18.8 (1.3) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliably Page 2 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or IS07-1R1/2 Sensitivity Nominal K-Factor: 4.9 (71 metric) Fast -response Max. Working Pressure: 175 psi (12 bar) Temperature Ratings 155°F (68°C) Material Specifications 175°F (79°C) Thermal Sensor: 3 mm glass -bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy F1 Recessed Button: Copper Alloy F2 Recessed Sealing Assembly: Nickel Alloy with PTFE FV Recessed* Load Screw: Bronze Alloy Sprinkler Wrenches ' Deflector: Bronze Alloy Model W2 Model W4 (Recessed) *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1 Res49 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) 2-1/4" (57mm) DIA. Face of fitting DIA. Face of fitting 1-15/16" to finished 1-15/_ to finished (49mm) DIA. ceiling (49mm) DIA. ceiling 5/8" (16mm) 1/2" (13mm) +/- 3/8" (9mm) +/ 1/4" (6mm) fYJStltI 2-1/4" (57) 1-5/8" (41mm) +/- 1-3/4" (44mm) +/- 3/8" (9mm) 1/4" (6mm) 1-1/4" y I I (32mm) 2-7/8" (72mm) DIA. 2-7/8" (72mm) DIA. Dimensions F1 Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model F1 Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe SystemsM Maximum Coverage Areai2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 13 (49) 7.0 (0.48) 1 to 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9 x 4.9) 13 (49) 7.0 (0.48) 18 x 18 (5.5 x 5.5) 17 (64) 12.0 (0.83) 20 x 20 (6.1 x 6.1) 20 (76) 16.7 (1.15) 12 x 12 (3.7 x 3.7) 15 (57) 9.4 (0.65) 4 to 8 inches (100 to 200 mm) 14 x 14 (4.3 x 4.3) 16 (61) 10.7 (0.74) 16 x 16 (4.9 x 4.9) 17 (64) 12.0 (0.83) 18 x 18 (5.5 x 5.5) 19 (72) 15.0 (1.03) 20 x 20 (6.1 x 6.1) 22 (83) 20.2 (1.39) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliably Page 3 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or ISO7-1 R1/2 Sensitivity Nominal K-Factor: 5.8 (84 metric) Fast -response Max. Working Pressure: 175 psi (12 bar) Temperature Ratings 155°F (68°C) Material Specifications 175°F (79°C) Thermal Sensor: 3 mm glass bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy F1 Recessed Button: Copper Alloy F2 Recessed Sealing Assembly: Nickel Alloy with PTFE FV Recessed* Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model W4 (Recessed) r *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1 Res58 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) 2-1/4" (57mm) DIA. Face of fitting DIA. Face of fitting 1-15/16" to finished 1-15/16" to finished 4 (49mm) DIA. ceiling (49mm) DIA. ceiling 5/8" (1 6mm) 1/2" (13mm) +/ 3/8" (9mm) +/- 1/4" (6mm) fbSV!! 2-1/4" (57) I 1-3/4" (44mm) 1-5/8" (41mm) +/- 1/4" (6mm) 3/8" (9mm) 1-1/4" I (32mm) 2-7/8" (72mm) DIA. 2-7/8" (72mm) DIA. Dimensions F1 Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model F1 Res58 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16 (4.9 x 4.9) 16(61) 7.6(0.52) 1 to 4 inches (25 to 100 mm) 18 x 18 (5.5 x 5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1 x 6.1) 22 (83) 14.4 (1.0) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliably Page 4 of 15 April 2021 www.reliablesprinkler.com Finishes Technical Specifications (See Table N) Style: Pendent and Recessed Pendent Sensitivity Threads: 3/4" NPT or ISO7-1 R3/4 Fast -response Nominal K-Factor: 7.6 (109 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) Material Specifications 175°F (79°C) Thermal Sensor: 3 mm glass bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy F1 Recessed F2 RecessedFV Button: Copper Alloy Recessed* Sealing Assembly: Nickel Alloy with PTFE Sprinkler Wrenches Load Screw: Bronze Alloy Model Deflector: Bronze Alloy Model W4 (Recessed) fi *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1 Res76 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) 2-1/4" (57mm) DIA. Face of fitting DIA. Face of fitting 1-15/16" to finished 1-15/16" to finished (49mm) DIA. ceiling (49mm) DIA. ceiling 5/8" (16mm) 1/2" (13mm) +/- 3/8" (9mm) +/- 1/4" (6mm) 09SVH 09 2-1/4" (57) I 1-3/4" (44mm) 1-5/8" (41mm) +/- 1/4" (6mm) 3/8" (9mm) 1-5/8" I (44mm) 2-7/8" (72mm) DIA. 2-7/8" (72mm) DIA. Dimensions F1 Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model F1 Res76 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area (2) Flow Pressure Deflector to ft. x ft. (m x m) gpm (1/min) psi (bar) Ceiling Distance 18 x 18 (5.5 x 5.5) 21 (80) 7.6 (0.52) 1 to 4 inches (25 to 100 mm) 20 x 20 (6.1 x 6.1) 23 (87) 9.2 (0.63) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliably Page 5 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPT or IS07-1 R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model W4 *Note: Model FP escutcheons and CCP cover plates are not listed for use in positively pressurized ceiling plenums. Model F1 Res30 CCP and FP Recessed Pendent Sprinkler Installation Dimensions 9_R/JQ1- tP,7 --. CCP Recessed Escutcheon Installation 2-5/8" (67mm) DIA. 2-5/16" (59mm)DIA. :ace of fitting to finished ceiling Face of fitting to finished ceiling -1/4" (32mm) 1-1/4" (32mm) / 1/4" (6mm) +/ 1/4" (6mm) 15/16"4mm 1" /4" (6m (24mm) +/- 1/4" (6mm) L3-3/16" (78mm) DIA. FP Recessed Escutcheon Installation Model F1 Res30 CCP Pendent & FP Recessed Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area (2) Flow Pressure Deflector to Ceiling Distance ft. x ft. (m x m) gpm (1/min) psi (bar) 12 x 12 (3.7 x 3.7) 8 (30) 7.0 (0.48) 1/2 to 1 inch (13 to 25 mm) 14 x 14 (4.3 x 4.3) 11 (38) 13.4 (0.92) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Reliably Page 6 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPT or ISO7-1 R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model W4 *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model F1 Res49 CCP & FP Recessed Pendent Sprinkler Installation Dimensions 7_V/R-1 /R7mm1 CCP Recessed Escutcheon Installation 2-5/8" (67mm) DIA. 2-5/16" (59mm)DIA. ace of fitting to finished ceiling i Face of fitting to finished ceiling -1/4" (32mm) 1-1/4" (32mm) /- 1/4" (6mm) o , r, +/- 1/4" (6mm) 15/16"4mm 1" /4" (6m (24mm) +/- 1/4" (6mm) L3-3/16" (78mm) DIA. - FP Recessed Escutcheon Installation Model F1 Res49 CCP Pendent and FP Recessed Pendent Hvdraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 14 x 14 (4.3 x 4.3) 13 (49) 7.0 (0.48) 1/2 to 1 inch (13 to 25 mm) 16 x 16 (4.9 x 4.9) 14 (53) 8.2 (0.57) 18 x 18 (5.5 x 5.5) 18 (68) 13.5 (0.93) 20 x 20 (6.1 x 6.1) 20 (76) 16.7 (1.15) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Reliably Page 7 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPT or IS07-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model W4 *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model F1 Res58 CCP and FP Recessed Pendent Sprinkler Installation Dimensions 2-5/8" (67mm) 2-5/8" (67mm) DIA. I DIA. CCP Recessed Escutcheon Installation 2-5/16" (59mm)DIA. ace of fitting to finished ceiling Face of fitting to finished ceiling -- 1/4" (32mm) 0 1-1/4" (32mm) - 1/4" (6mm) �, T r,,,, T„ +/- 1/4" (6mm) 11" m) (24mm4mm) L \4V +/- 1/4/4"" (6mm) 3-3/16" (78mm) DIA. FP Recessed Escutcheon Installation Model F1 Res58 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria - Minimum Flow and Residual Pressure in Wet Pipe Systems(' Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16 (4.9 x 4.9) 16(61) 7.6(0.52) 112 to 1 inch (13 to 25 mm) 18 x 18 (5.5 x 5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1 x 6.1) 22 (83) 14.4 (1.0) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Reliable Page 8 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Finishes Style: Conical Concealed Pendent and (See Table N) Recessed Pendent Sensitivity Threads: 3/4" NPT or ISO7-1 R3/4 Fast -response Nominal K-Factor: 7.6 (109 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) Recessed Escutcheons/Cover Plates Material Specifications CCP Conical Concealed Plate 135°F (57°C)* Thermal Sensor: 3 mm glass bulb FP Recessed* Sprinkler Frame: Brass Alloy Sprinkler Wrenches Button: Copper Alloy Model W4 Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model F1 Res76 CCP and FP Recessed Pendent Sprinkler Installation Dimensions ace of fitting to finished ceiling -1/4" (32mm) 1- 1/4" (6mm) 15/16" (24mm) CCP Recessed Escutcheon Installation FP Recessed Escutcheon Installation Model F1 Res76 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria -ace of fitting to finished ceiling -1/4" (32mm) /- 1/4" (6mm) 1" (25mm) /- 1/4" (6mm) Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area (2) Flow Pressure Deflector to Ceiling Distance ft. x ft. (m x m) gpm (1/min) psi (bar) 16 x 16 (4.9 x 4.9) 21 (80) 7.6 (0.52) 1 inch 1/2 (13 to o 25 mm) 18 x 18 (5.5 x 5.5) 22 (83) 8.4 (0.58) 20 x 20 (6.1 x 6.1) 25 (95) 10.8 (0.75) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 ReliablE� Page 9 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2" NPT or ISO7-1 R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model W4 (Recessed) �dv I� Model F1 Res44 Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 1-5/8" (41mm) 2-7/16" (62mm) 5/16" (8mm) Dimensions 3/8" (10mm) +/- 1/4" (6mm) 2-1/4" 1-15/16" (57mm) (49mm) - - DIA. DIA. +/- 1/4" (6mm) Top of Deflector Down from _ Ceiling to be Either 4" to 6" (100 to 150 mm) or 6" to 12" (150 to 300 mm) Based on Hydraulic Calculations F2 & FV Recessed Escutcheon Installation Model F1 Res44 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe SystemsM Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 12 (45) 7.5 (0.52) 4 6 inches (100 to 150 mm) t 14 x 14 (4.3 x 4.3) 14 (53) 10.2 (0.70) 15 x 15 (4.6 x 4.6) 15 (57) 11.6 (0.80) 16 x 16 (4.9 x 4.9) 16 (61) 13.3 (0.92) 16 x 18 (4.9 x 5.5) 18(68) 16.8(1.16) 16 x 20 (4.9 x 6.1) 23 (87) 27.4 (1.89) 18 x 18 (5.5 x 5.5) 19 (72) 18.7 (1.29) 12 x 12 (3.7 x 3.7) 14 (53) 10.2 (0.7) 6 to 12 inches (150 to 300 mm) 14 x 14 (4.3 x 4.3) 16(61) 13.2(0.91) 15 x 15 (4.6 x 4.6) 16 (61) 13.2 (0.91) 16 x 16 (4.9 x 4.9) 17 (64) 15.0 (1.03) 16 x 18 (4.9 x 5.5) 20 (76) 20.7 (1.43) 16 x 20 (4.9 x 6.1) 23 (87) 27.4 (1.89) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliably Page 10 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Sidewall Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass -bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) 175°F (79°C) (1) Cover Plates SWC Conical Concealed Plate (2) SWC-2 (Slotted) Conical Concealed Plate(3) Sprinkler Wrenches Model W4 1 SWC SWC-2 1 Note: (1) Not for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating. (2) 135°F SWC Conical Concealed Plate for 155°F (68°C) sprinklers (3) 135°F SWC-2 (Slotted) Conical Concealed Plate for 175°F (79°C) sprinklers Model F1 Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler and Installation Dimensions 1" (25mm) 1" (25mm) +/- 1/4" (6mm) 1/4" (6mm) Face of fitting to finished wall 2-5/16" ------ Top of Deflector Down from Ceiling to be Either 3 5/16" (67mm) (58mm) - - - 4" to 6" (100mm to (84mm) DIA. j DIA. 150mm) or 6" to 12" DIA. 5/161, (150mm to 800mm) (8mm) Based on Hydraulic Calculations 1 5/8" (41 mm) Dimensions SWC & SWC-2 Concealed Cover Plate Installation Model F1 Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems('( Maximum Coverage Area (2) ft. x ft. (m x m) Ordinary Temperature Rating 155°F (68°C) Intermediate Temperature Rating 175°F (79°C) Deflector to Ceiling Distance Flow gpm (I/min) Pressure psi (bar) Flow gpm (I/min) Pressure psi (bar) 12 x 12 (3.7 x 3.7) 13 (49) 8.7 (0.60) 14 (53) 10.2 (0.7) 14 x 14 (4.3 x 4.3) 14 (53) 10.2 (0.7) 14 (53) 10.2 (0.7) 15 x 15 (4.6 x 4.6) 16 (61) 13.2 (0.91) - - - - 4 to 6 inches 16 x 16 (4.9 x 4.9) 17 (64) 15.0 (1.03) -- _ (100 to 150 mm) 16 x 18 (5.5 x 5.5) 19(72) 18.7(1.31) -- -- 16 x 20 (4.9 x 6.1) 23 (87) 27.4 (1.89) - - - - 12 x 12 (3.7 x 3.7) 14 (53) 10.2 (0.7) - - - - 14 x 14 (4.3 x 4.3) 15 (57) 11.7 (0.81) - - - - 15 x 15 (4.6 x 4.6) 17 (64) 15.0 (1.03) - - 6 to 12 inches (150 to 300 mm) 16 x 16 (4.9 x 4.9) 18 (68) 16.8 (1.16) -- -- 16 x 18 (4.9 x 5.5) 20 (76) 20.7 (1.43) -- -- Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliably Page 11 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2" NPT or ISO7-1 R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) 175°F(79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model W4 (Recessed) Model F1 Res58 Residential Horizontal Sidewall Sprinkler Installation Dimensions 2-7/16" (62mm) 5/16" (8mm) Dimensions Face of fitting to finished wall 3/8" (10mm) +/- 1/4" (6mm) 2-1/4" 1-15/16" (57mm) (49mm) DIA. DIA. 1-5/8" (41mm) +/- 1/4" (6mm) F2 & FV Recessed Escutcheon Installation Model F1 Res58 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Top of Deflector Down from Ceiling to be Either 4" to 6" (100 to 150 mm) or 6" to 12" (150 to 300 mm) Based on Hydraulic Calculations Minimum Flow and Residual Pressure in Wet Pipe Systems') Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 16 (61) 7.6 (0.52) 4 to 6 inches (100 to 150 mm) 14 x 14 (4.3 x 4.3) 18 (68) 9.7 (0.66) 15 x 15 (4.6 x 4.6) 19 (72) 10.7 (0.74) 16 x 16 (4.9 x 4.9) 21 (80) 13.2 (0.91) 16 x 18 (5.5 x 5.5) 25 (95) 18.6 (1.28) 16 x 20 (4.9 x 6.1) 29 (110) 25.0 (1.72) 12 x 12 (3.7 x 3.7) 22 (83) 14.4 (1.0) 6 to 12 inches (150 to 300 mm) 14 x 14 (4.3 x 4.3) 22 (83) 14.4 (1.0) 15 x 15 (4.6 x 4.6) 24 (91) 17.1 (1.18) 16 x 16 (4.9 x 4.9) 26 (98) 20.1 (1.39) 16 x 18 (4.9 x 5.5) 31 (117) 28.6 (1.97) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. Please note SIN difference between F1 Res58 HSW (R3533) and F1 Res58 HSWX (RA3533). Bulletin 135 Reliably Page 12 of 15 April 2021 www.reliablesprinkler.com Finishes Technical Specifications (See Table N) Style: Sidewall and Recessed Sidewall Sensitivity Threads: 1/2" NPT or ISO7-1 R1/2 Fast -response Nominal K-Factor: 5.8 (84 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) 175°F (79°C) 4 Material Specifications Recessed Escutcheons , Thermal Sensor: 3 mm glass bulb F2 Recessed ( Sprinkler Frame: Brass Alloy FV Recessed Button: Copper Alloy Sprinkler Wrenches IJ Sealing Assembly: Nickel Alloy with PTFE Model W2 Load Screw: Bronze Alloy Model W4 (Recessed) Deflector: Bronze Alloy Model F1 Res58 HSWX Residential Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 1-7/8" (48mm) 3/8" (10mm) +/ 1/4" (6mm) +/ 1/4" (6mm) 2-7/8" (73mm) 2-1/4" 1-15/16" Top of Deflector Down From (57mm) (49mm) - - -- Ceiling to be Either 4" to 6" DIA. DIA. (100 to 150 mm) or 6" to 12" (150 to 300 mm) Based on 5/16° Hydraulic Calculations (8mm) Dimensions F2 & FV Recessed Escutcheon Installation Model F1Res58 HSWX Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems') Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 18 x 20 (5.5 x 6.1) 30 (114) 26.8 (1.85) 4 to 6 inches (100 to 150 mm) 20 x 20 (6.1 x 6.1) 30 (114) 26.8 (1.85) 16 x 22 (4.9 x 6.7) 33 (125) 32.4 (2.23) 16 x 24 (4.9 x 7.3) 38 (144) 42.9 (2.96) 14 x 26 (4.3 x 7.9) 42 (160) 52.4 (3.63) 18 x 20 (5.5 x 6.1) 35 (133) 36.4 (2.51) 6 to 12 inches (150 to 300 mm) 16 x 22 (4.9 x 6.7) 38 (144) 42.9 (2.96) 16 x 24 (4.9 x 7.3) 42 (160) 52.4 (3.61) 14 x 26 (4.3 x 7.9) 46 (174) 62.9 (4.34) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. Please note SIN difference between F1 Res58 HSW (R3533) and F1 Res58 HSWX (RA3533). Bulletin 135 Reliable Page 13 of 15 April 2021 www.reliablesprinkler.com Finishes Standard Finishes Special Application Finishes Sprinkler<'� F1, F2. FV, FP(3), CCP, SWC (Conical) Sprinkler �'� F1, F2. FV, FP(3), CCP, SWC (Conical) Escutcheons Cover Plates �'� Escutcheons Cover Plates (') Bronze Brass Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Satin Chrome Satin Chrome Satin Chrome White White White Paint Black Black Black Paint Polyester 2> Polyester Polyester (2) Polyester Custom Color Custom Color Custom Color Paint Polyester Polyester Electroless Nickel - - - PTFE (2) - Notes: (1) Paint or any other coating applied over the factory finish will void all approvals and warranties. (2) cULus Listed Corrosion Resistant. (3) The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Installation Models F1 Res sprinklers are to be installed as shown in this bulletin. Model F1, F2, FV, and FP recessed escutcheons are the only recessed escutcheons to be used with Model F1 Res sprinklers. Not all F1 Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutcheon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models F1 Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC-2) sprinklers use only the Model W4 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Installation of F1 Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4" (57 mm) for F1 or F2 recessed escutcheons; or 2-5/8" (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC-2 cover plates. Install F1 Res HSW sprinklers with a ceiling to deflector distance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and "Top" marking must face the ceiling. A 'leak tight" sprinkler joint can be obtained with the following torque: • 1/2" NPT and ISO7-1 R1/2: 8-18 ft-Ibs (11 — 24 N-m) • 3/4" NPT and ISO7-1 R3/4: 14-20 ft-Ibs (19 — 27 N-m) Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Model W2 Model W4 Model W4 Wrench Installation Examole 1P The Model W4 wrench includes two sets of jaws. One set of jaws is equivalent to a Model GFR2 wrench and the other set of jaws is equivalent to a Model W1 wrench. Use the smallest of the two sets of jaws that will fit on the sprinkler's wrench flats. The Model W4 wrench is used in conjunction with the installer's nominal 1/2" square drive ratchet and nominal 5" (125mm) long extension (not provided) as shown in Figure 13. Bulletin 135 April 2021 Page 14 of 15 www.reliablesprinkler.com Maintenance Reliable Model F1 Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non -operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non -operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler • Model (See Table A) • Temperature Rating • Threads (NPT or IS07-1) • Finish (See Table N) Escutcheon or Cover Plate • Model • Finish (See Table N) Sprinkler Wrench • Model W2 (Pendent and HSW) • W4 (Recessed and Concealed) Note: Please note SIN difference between F1 Res58 HSW (R3533) and F1 Res58 HSWX (RA3533). Ln N O 0) M 0) Z d Bulletin 135 ReliablE� Page 15 of 15 April 2021 www.reliablesprinkler.com Bulletin 014 December 2021 Reliable Model F1 FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model F1 FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model F1 FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1 FR42, F1 FRXLH & F1 FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model F1 FR40 Sprinkler Types Standard Spray Pendent Model F1 FR42, F1 FR40, F1 FRXLH & F1 FR28 Recessed Sprinkler Types Standard Spray Pendent Model F1 FR56LL & F1 FR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Con- tent Listing & Approvals The following organizations provide Listings or Approvals for various Model F1 FIR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprinkler. 1. Underwriters Laboratories Inc. and Certified for Cana- da (cULus) in accordance with ANSI/UL199. 2. FM Approvals (FM) 3. Loss Prevention Certification Board (LPCB) 4. VdS Schadenverhutung GmbH (VdS) 5. Underwriters Laboratories Inc. and Underwriters Lab- oratories of Canada Certified for Health Effects to NSF/ ANSI Standard 61 Annex G (ULH) 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) (EC) 7. WaterMark certified. Certificate Number 23347. (WM) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Model F1 FR Series Quick Response Glass Bulb Sprinklers Upright Pendent Conventional Allilsilol Vertical Sidewall 1 Recessed Horizontal Sidewall Horizontal Sidewall Concealed Pendent Recessed Pendent/F1/F2 I& Recessed Pendent/FP El XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 Product Description �W Reliable Model F1 FR series sprinklers are quick -response automatic sprinklers with a glass bulb thermal element. Model,, F1 FIR series sprinklers are Standard Spray sprinklers, with the exception of the Model F1 FR56 Conventional sprinkler which is XLH Recessed an Old-style/Conventional sprinkler. Pendent FP The Model F1 FIR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FIR Series sprinklers to apply water to a fire faster than standard -response sprinklers of the same tem- perature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufac- tured glass capsule. This glass bulb is specially constructed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. Model F1 FIR Series sprinklers provide a wide range of options where quick -response, glass bulb sprinklers are used: • Pendent, recessed pendent, upright, horizontal side - wall, and vertical sidewall deflectors • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) • Flush, recessed, and concealed installations See the Design and Installation Information table in this Bul- letin for information on the approvals and availability of specific Model F1 FIR series sprinkler configurations. Model F1 FIR Recessed Pendent and Recessed Horizontal Sidewall sprinklers are required to be used with Reliable Model F1, F2, or FP recessed escutcheons. See the Recessed Es- cutcheon Data table in this Bulletin for listing and approval infor- mation with each specific Model F1 FIR series sprinkler. Model F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2- inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cover plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.Omm) of cover plate adjustment. See the Design and Installation Infor- mation and Listed and Approved Temperature Ratings tables in this Bulletin for further information on approved cover plate options. Application Model F1 FIR Series sprinklers are intended for use in ac- cordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Having Juris- diction. Care must be exercised that the k-factor, tempera- ture rating, deflector style, and sprinkler type are in accor- dance with the requirements of the applicable design and installation standards. In addition, Model F1 FIR Series sprin- klers must be used in accordance with their listings and ap- provals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or protec- tive caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Re- move the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protec- tor before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Model F1 FIR Series sprinklers must be installed with the Reli- able sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model F1 FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the specific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1 FIR Series Recessed sprinkler. The use of any other recessed escutcheon will void all approvals and negate all warranties. Concealed Sprinklers Model F1 FIR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers have a facto- ry -installed Model CCP cup. A protective cap is installed at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread- off cover plate assembly. The cover plate and sprinkler cup as- semblies are joined using a cover plate skirt with flexible tabs for threaded engagement. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1 FIR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1 FIR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model W4 wrench is used to engage the sprinkler wrenching sur- faces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent dam- age to the sprinkler. Do not wrench any other part of the sprinkler/ cup assembly. Installation is completed by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/ cup assembly other than the Reliable Model CCP with Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not spe- cifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. 2. Technical Data: Sensitivity: Quick -response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height Installation Wrench SIN Listings and Approvals Approval Notes US Metric inches mm inches mm Pendent 2.25 57 W2 RA1411 cULus 2 F1 FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 W4 RA1411 cULus 2 Upright 2.25 57 W2 RA1421 cULus 1,2 F1 FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 W4 RA1418 VdS Pendent 2.25 57 W2 RA1413 cULus 2 F1 FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1 FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 W4 RA1410 cULus, ULH F1 FRXLH Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 (F1 FR42 4.2 60 7/16 10 with Pintle) Upright 2.25 57 W2 RA1423 cULus 1,2 cULus, FM, Pendent 2.25 57 W2 RA1414 LPCB, VdS, EC, 1,2,3,4 WM cULus, FM, Recessed Pendent 2.25 57 W4 RA1414 LPCB, VdS, EC, 1,2,3,4 WM F1 FR56 5.6 80 112 15 Concealed Pendent 2.25 57 W4 RA1414 cULu VdS,EC, WM 5,6 cULus, FM, Upright 2.25 57 W2 RA1425 LPCB, VdS, EC, 1,2,3,4 WM "Conventional (Pendent or Upright)" 2.25 57 W2 RA1475 LPCB, VdS, EC, WM 4 Pendent 2.25 57 W2 RA1415 cULus, ULH 1 Fl FR56LL 5.6 80 112 15 Recessed Pendent 2.25 57 W4 RA1415 cULus, ULH Concealed Pendent 2.25 57 W4 RA1415 cULus, ULH 6 Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 F1FR56 5.6 80 1/2 15 Recessed Horizontal Sidewall 2.63 67 W4 RA1435 cULus, FM 8 F1 FR56 5.6 80 112 15 Vertical Sidewall (Pen- dent or Upright) 2.25 57 W2 RA1485 cULus, FM, LPCB 1,2,3,9 (1) cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3) Available with FM approved Polyester coating in black or white. (4) Available with LPCB and VdS approved Polyester coating. 5> VdS and EC approvals of the F1 FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprinklers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. (6) Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. (7) cULus Listing of the F1 FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the F1 FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (8) cULus Listing and FM Approval of the F1 FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9) The F1 FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the F1 FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100T (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150T (65°C) Max. Ambient Temp. High Temp. Classification 225°F (107°C) Max. Ambient Temp. 135°F (57°C) Temp. R ting 155°F (68°C) Temp. Rating 175°F (79°C) Temp. Rating 200°F (93°C) Temp. Rating 286°F (141°C) Temp - Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1 FR28 Recessed Pendent cULus Upright cULus Pendent VdS F1 FR40 Recessed Pendent VdS Pendent cULus F1 FR42 Recessed Pendent cULus Upright cULus F1 FR42LL Pendent Recessed Pendent cULus, ULH cULus, ULH Pendent cULus F1 FRXLH Recessed Pendent cULus Upright cULus Pendent cULus, FM, LPCB, VdS, EC, WM Recessed Pendent cULus, FM, LPCB, VdS, EC, WM F1FR56 Concealed Pendent cULus, WM cULuNVMS,EC, cULus, WM Upright cULus, FM, LPCB, VdS, EC, WM "Conventional Pendent or Upright)' LPCB, VdS, EC, WM Pendent cULus, ULH F1 FR56LL Recessed Pendent cULus, ULH Concealed Pendent* cULus, ULH Horizontal Sidewall cULus, FM F1 FR56 Recessed Horizontal Sidewall cULus, FM F1 FR56 Vertical Sidewall (Pen- dent or Upright) cULus, FM, LPCB * Model F1 FR56 Concealed Pendent and F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 1350F (57°C) temperature rated cover plate. For In- termediate Temperature Classification sprinklers use a 1650F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Model F1 Model F2 Model FP Deflector/ Model (Fig. 1 & 3) (Fig. 1 & 3) (Fig. 2) SIN Orientation 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 FlFR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC, WM RA1414 EC, WM VdS, EC, WM FlFR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 F1 FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS F7 ESCUTCHEON '7� 3/4T Tl9mm19mm] ADJUSTMENT F2 ESCUTCHEON 1/2'T 72. 7mm] ADJUSTMENT 2 518" DIA. HOLE IN C 2 5/16" DIA. CUf CEILING %2'T 12.7mmj ADJUSTMEN7 2 114" HOLE DIA. [57.2mm] 1 15116" DIA [49.2mm] F- 1--- -1 II II LJ� 2 27/32" DIA. [72.2mm] 1 " X 112" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = 1 "T25.4mm] AT MINIMUM RECESS = 318'T9.5mml F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4'T79mm] j -7 -77--� AT MINIMUM RECESS = 3/8'T9.5mm] F1 ESCUTCHEON AT MAXIMUM RECESS = 7/8'T22.2mm] [3.2mm] AT MINIMUM RECESS = 1-518'T41.3mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8'T28.6mm] AT MINIMUM RECESS = 1-5/8'T41.3mm] Fig. 1 Model F1 FR56, F1 FR56LL, F1 FR42, F1 FR40, F1 FR42LL, F1 FRXLH & F1 FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon ., . �_DUCER FACE OF FITTING TO FACE OF CEILING DIMENSION IT MAXIMUM RECESS = 1-1/2'T38mm] IT MINIMUM RECESS = 1'T25.4mm] RECESS = 9/16'[14.3mm] 2ECESS = 1 'T25. 4mm] 3 DIA. [82.62.6mmJ Fig. 2 Model F1 FR56, F1 FR56LL, F1 FR42, F1 FR40, F1 FR42LL, F1 FRXLH & F1 FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. N N O N FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = 1 'T25.4mm] AT MINIMUM RECESS = 3/8'T9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4'T 19mm] AT MINIMUM RECESS = 3/8'T9.5mm] 2 114 " HOLE DIA. [57.2mm] 1 " X 112" REDUCER I � 'iii� � n� 1 15/16" DIA. )'11'miins' ' _ [49.2mm] lu IN L_uui I TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. 1/8 "" [J.2mm] F1 ESCUTCHEON AT MAXIMUM RECESS = 1 3 8" 34 9 — / [ . mm] AT MINIMUM RECESS = 2-1/16"T52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8'T41.3mm] AT MINIMUM RECESS = 2-1/16'T52.4mm] 2 27/32" DIA. [72.2mm] F7 ESCUTCHEON 3/4'[19mm] ADJUSTMENT F2 ESCUTCHEON 1/2'T 12.7mm] ADJUSTMENT 1 (1) 4 "-12 "" [101.6mm-304.8mm] CEILING TO DEFLECTOR oiarcor RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" — 6" [101.6MM — 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig. 3 Model F1 FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon I" x 112" REDUCING TEE OR ELBOW 2 5116 " DIA — CUP ---- --- +-------- - — - — - — r- 2 518" DIA. �! HOLE IN CEILING 1 112 " MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING j I 112 " MAX. COVER ADJUSTMENT r COVER PLATE / ASSEMBLY 3 5116 " DIA SPRINKLER j CONCEALED, 1 /2" ADJUSTMENT 017FG01A Fig. 4 Model F1 FR56/1`1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate L:l Q 1 " x 112" REDUCING TEE OR ELBOW IIII 2 5/8 " DIA. 2 5/16" DIA ;' HOLE IN CEILING CUP 00 tld 1 112 " MAX. FACE OF FITTING """"� TO FACE OF CEILING DIMENSION CEILING I 5116 " MAX. COVER ADJUSTMENT J� j COVER PLATE ASSEMBLY 3 5/16 DIA. SPRINKLER CONCEALED, 5/16" ADJUSTMENT 017FG02A Fig. 5 - Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16- inch (8.Omm) adjustment - Model CCP cover plate Maintenance The Model F1 FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Finishes (1) (2) Standard Finishes Sprinkler Escutcheon Cover plate Bronze Brass Chrome Chrome Chrome White White Polyester (3)(6)(7) White Special Application Finishes Sprinkler Escutcheon Cover plate Electroless Nickel PTFE(3)(4) Electroless Nickel PTFE Bright Brass Black Polyester (3)(6)(7) Bright Brass Black Bright Brass (1) Black Off White Off White(6)(7) Off White Satin Chrome Satin Chrome Satin Chrome (1) Other finishes and colors may be available on special order. Consult the factory for details. (2) Paint or any other coating applied over the factory finish will void all approvals and warranties. (3) cULus Listed as Corrosion Resistant. (4) FM Approved as Corrosion Resistant for SIN RA1414, RA1425, RA1435, and RA1485. (6) 200"F (93"C) maximum temperature rated sprinkler only. (6) VdS Approved for RA1425, RA1414, RA1418, and RA1475. (1) LPCB Approved for RA1425, RA1414, and RA1475. Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: 1. Sprinkler Model: [F1 FR28][F1 FR40][F1 FR42] [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent] [Uprig ht][Conventional][HorizontaI Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F (68°C)][175°F (79°C)][200°F (93°C)][286°F (141°C)] 5. Sprinkler Finish 6. Escutcheon Model: [F1][F2][FP] 7. Escutcheon Finish (where applicable) 8. Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.Omm) adjustment] 9. Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note: When Model F1 FIR Series Recessed sprinklers are ordered, the sprin- klers and escutcheons are packaged separately. 7. Q J X N Y 0 Y N Y 0 U) 0 0 0 :N U) co w 0 z N N 0 N C Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many pre- cision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address ® Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 12/21 P/N 9999970300 Bulletin 013 Rev. N Model F156 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F156 Recessed Sprinkler Types Pendent/F1 /F2/FP Horizontal Sidewall Model F142, F1XLH & F128 Sprinkler Types Standard Upright Standard Pendent Model F142, F1XLH & F128 Recessed Sprinkler Types Pendent/F1 /F2/FP Approval Organizations 1. Underwriters Laboratories Inc. and certified for Canada (cULus) 2. Factory Mutual Approvals (FM) 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhutung GmbH 5. EC Certificate: 0786-CPD-40237 (RA1314) 0786-CPD-40253 (RA1325) 0786-CPD-40254 (RA1375) UL Listing Category Sprinklers, Automatic & Open (VNIV) Product Description The F156, F142, F1XLH & F128 Series Glass Bulb Sprinkler combines the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. Whether installed on exposed piping or in an office ceil- ing, it is functional and attractive. Beautifully versatile is the description for the Reliable Models F156, F142, F1XLH & F128 Series Recessed glass bulb sprinkler. Recessing the F156, F142, F1XLH & F128 Series enhances its already low profile decorative appearance, and facilitates a rapid and perfect installa- tion. The recessed escutcheon of the Models F156, F142, F1XLH & F128 are highly adjustable. The two piece con- struction makes field installation a very easy and rapid task. This also allows ceiling panels to later be removed without shutting down the fire protection system, thus fa- cilitating maintenance of above ceiling services. Models F1 Series Standard Response Sprinklers Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed Pendent/F1 /F2 Recessed Recessed XLH Upright Horizontal Sidewall Pendent/FP XLH Pendent Pendent F1 /F2 XLH Recessed Pendent FP The F156, F142, F1XLH & F128 Series Automatic Sprin- kler utilizes a 5.0 mm frangible glass bulb. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid phase and in the vapor phase. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. The F156, F142, F1XLH & F128 Series Sprinkler tem- perature rating is identified by the color of the glass bulb capsule as well as frame color where applicable. 0J m 0 w z Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Pin tle (XLH Only Deflector Load Screw Washer Bulb Frame Cup 07JFG04 Model F142, F1XLH Upright Technical data: Thread Max. Min. Temperature Models Nominal K-Factor Response Size Working Working Rating Finish Pressure Pressure F156 5.6 (80 Metric) 12" NPT See See F142 F1XLH 4.2 (60 Metric) Standard (R'h) 175 PSIM 7 PSI "Temperature " Finish Table" Ratings" Table F128 2.8 (40 Metric) Material Data: Frame Deflector Load Screw Pintle Cup Washer Bulb DZR Brass CDA Alloy 22 CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass or or or or coated with PTFE Adhesive Glass CDA Alloy 510 CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape (1) Model F156 upright, pendent, and recessed pendent sprinklers (SIN RA1325 and RA1314) are cULus Listed for 250 psi (17 bar). 2. Model F156, Upright, Pendent & Conventional Sprinklers Model F142, F1 XLH & F128 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench or Model W2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size Nominal K-Factor Sprinkler Height Approval Organization Sprinkler Identification Number SIN US Metric U ri ht Pendent Standard -U ri ht SSU and Dendent Deflectors Marked to Indicate Position 1/2' 15mm (1) 1/2" NPT R'/z 5.6 80 2.25" 57mm 1 2 3 4 5 RA1325(2)(3)(5)(6) RA1314(2)(3)(bus) '/1 " 10mm 1/z" NPT R7/z 4.2 60 2.25" 57mm 1 RA1323(2)(6) RA1313(6) 3/8" 10mm 1/2" NPT 197/2 2.8 40 2.25" 57mm 1 RA1321(2)(6) RA1311(6) Conventional -Install in Upright or Pendent Position 15mm (1) 1/2" NPT R1/25.6 80 1 57mm 1 3 4 5 1 RA1375(5) (1) Refer to Bulletin 024 for Special Response Sprinklers (F1S5-56) (2) cULus Listed corrosion resistant (Polyester coated) sprinkler. (3) Polyester coated FM Approved sprinkler. (4) ----- (5) Polyester coated LPCB & VdS approved sprinkler RA1325, RA1314 & RA1375. (6) Electroless Nickel PTFE Plated - UL listed Corrosion Resistant Upright Pendent Model F156, F1425 F1XLH & F128 Recessed Pendent Sprinklers') Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Conventional Nominal Orifice Thread Size Nominal K-Factor Sprinkler Height Sprinkler Identification Number SIN US Metric 1/2" 15mm 1/2" NPT R1/2 5.6 80 2.25" 57mm RA1314(2) '/16" 10mm 1/2" NPT R1/2 4.2 60 2.25" 57mm RA1313(2) 3/8" 10mm 1/2" NPT R1/2 2.8 40 2.25" 57mm RA1311(2) (1) Refer to escutcheon data table for approvals & dimensions (2) Electroless Nickel PTFE Plated - cULus listed Corrosion Resistant «�2mm] 9M �s�rB" 9M 49.2mm� — i 1 X 1/ " REouccR NRN couAR � — vraEvscNceossKLER AT" TO FACE OF CEILING DIMENSION -� ill MAzruuM REccss = 1 [zs amm] H 6 �7 L AT MINIMUM RECESS = J/B[9.Smm] FZ ESCUTCH FJ/4 [19mm] AT MAXIMUM RECESS = J/4 [19mm] ul F2sculI E F Stl� Ar MrvrmuM REccss = J/B [e.smm] �rcH 1/2[12]mm1 FI ESCUTCHEON AMUSTMENT AT MAXIMUM RECESS ]/B [222mm] [3Tmm] AMINIMUM yRECE55 = 1-5/8T4I-] AT MAXIMUMr RECESS = 1-1/8[28.b 1 MINIMUM RECEss 1-5/a T4I-] 2 ]/J2' [J22mm]M o IJFG0IC RECESSED PENDENT W/F1 OR F2 ESCUTCHEON SPRINKLER NOT FM APPRG✓ED WITH 11 - Model F156, F142, F1XLH & F128 F1 or F2 r— Ir 1" X 1/2" REDUCER DIA. [66. ]mmJ HOLE IN CEILING I I I / 2 5/16" DIA. 158.]m1] CUP L J CEILINC FACE OF FITTING TO FACE OF CEILING DIMENSION Ii\ AT MAXIMUM RECESS = 1-1/2'[38mm] AT MINIMUM RECESS = 1 [254mm] 1j AT MAXIMUM RECESS = 9/16714.3mm] P [50.8mm] J AT MINIMUM RECESS = 1 [25.4mm] ADJUSTMENT 3 1/4" DIA. (826mm] RECESSED PENDENT W/FP ESCUTCHEON osFo2a +SPRINKLER NOT FM APPROVED WITH FP ESCUTCHEON Model F156, F142, F1XLH & F128 FP 3. Model F156 Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench or Model W2 Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy U.S. Patent No. 6,374,920 Sprinkler Type Deflector to Ceiling Distance (Min. - Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4" (102mm) - 12" (305mm) Installation Data: Vertical Sidewall Nominal Orifice Thread Size Nominal K Factor Sprinkler Height g Approval (1) Organizations g Sprinkler Identification US Metric Numbers (SIN) 1/2" (15mm) 112" NPT (R'/2) 5.6 80 2.25' (57mm) 1, 2, 3 RA13850)(2)(3)(4) (1) LPC Approval is pendent only, 57°C through 141 °C ratings. (2)cULus Listed corrosion resistant (Polyester coated) sprinkler. (3) cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. (4) Electroless Nickel PTFE Plated - cULus listed Corrosion Resistant Model F156 Horizontal Sidewall Sprinkler Deflector: HSW F— FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = 1'T25.4mm] AT MINIMUM RECESS = 3/8'T9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4'T79mm] AT MINIMUM RECESS 3/8'T9.5mm1 2 1/4" HOLE DIA. [57.2mm] I" X 1/2" REDUCER — F1 ESCUTCHEON AT MAXIMUM RECESS = 1-3/8'T34.9mm] AT MINIMUM RECESS = 2-1/16 [52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS 1-5/8[41. 3mm] F1/8" AT MINIMUM RECESS = 2-1/16[52.4mm] [3.2mm] 4"-12" ran. a......_ 49.2mmJ L 2 27/32" DIA. CEILING TO [72.2mm] DEFLECTOR TURN COLLAR UNTIL �1 TIGHT AGAINST SPRINKLER WRENCH BOSS. F7 ESCUTCHEON 3/4'T19mm] ADJUSTMENT F2 ESCUTCHEON 112'T12.7mml ADJUSTMENT RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" — 6- [101.6MM — 152.4MM] CEILING TO DEFLECTOR. (7) arm] Horizontal Sidewall Note: For Recessed HSW Sprinklers use installation wrench GFR2. FM and cULus permits use with F1 or F2 escutcheons for "Light Hazard" only. Installation Wrench: Model D Sprinkler Wrench or Model W2 Sprinkler Wrench Installation Data:Horizontal Sidewall Nominal K Factor Sprinkler Height Approval Organizations pp g Sprinkler Nominal Orifice Thread Size Identification US Metric Light Hazard Ordinary Numbers (SIN) Hazard 112" (15mm) 112" NPT (R1/2) 5.6 80 2.63" (67mm) 1,2 1 RA1335'>(2)(3)(4) (1)cULus Listed corrosion resistant (Polyester coated) sprinkler. (2) cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. (3) Polyester coated FM approved sprinkler. (4) Electroless Nickel PTFE Plated - cULus listed Corrosion Resistant Application Model F156, F142, F1XLH, F128 & Model F156, F142, F1XLH & F128 Recessed sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must exercised that the orifice size, temperature rating, deflector style and sprinkler type are in ac- cordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdic- tion Installation. Installation Model F156, F142, F1 XLH & F128 Series sprinklers are standard response sprinklers intended for installation as specified in NFPA 13. They must also be installed with the Model D Sprinkler Wrench or Model W2 Sprinkler Wrench specifically designed by Reliable for use with these sprinklers. The Model F156, F142, F1XLH & F128 Recessed Sprinklers are to be installed with a maximum recess of 3/4 inch (19mm). The Model F1, F2, and FP Escutcheon illustrated are the only recessed escutcheon to be used with the Model F156, F142, F1XLH & F128 Recessed Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model F156, F142, F1XLH & F128 Recessed Sprinklers use the Model GFR2 Sprinkler Wrench. Any other type of Wrench may damage these sprinklers. Note: A leak tight'/2" NPT (R1/2) sprinkler joint can be obtained with a torque of 8 -18 ft-lbs (11- 24 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impair- ment of the sprinklers. Glass bulb sprinklers have orange covers to protect the bulb dur- ing the installation process. REMOVE THIS PROTECTION ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO Wrenches are designed to install sprinklers when covers are in place. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Nominal K-Factor 4. Temperature Rating 5. Sprinkler Finish 6. Thread Type: [1/2" NPT] [ISO 7-1 R1/1 7. Escutcheon Finish (where applicable) Note: When Models F156, F142, F1XLH & F128 Recessed Sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Escutcheon Data (') (1) SIN: RA1335 - cULus and FM permits use with F1 or F2 escutcheons for light hazard only. Maintenance The Model F156, F142, F1XLH & Model F156, F142, F1X- LH & F128 Recessed Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluid. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause im- proper operation or non -operation. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color °C OF Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High0) 141 286 225°F (107°C) Blue Extra High0) 182 360 300°F (149°C) Mauve Ultra High (1)(2) 260 500 1 475°F 246°C Black (1) Not available for recessed Sprinklers. (2) cULus listed for SIN RA1325 and RA1314 only. Maximum Working Pressure 175 psi (12 bar) SIN RA1325 & RA1314 cULus listed for 250 psi (17 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finish(') Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome Polyester Coated (6)(7)(9) White Painted Special Aoolication Finishes Sprinkler Escutcheon Electroless Nickel PTFE(3)(10) Electroless Nickel PTFE Bright Brass(2) Bright Brass Black Plated Black Plated Black Paint)3)(9) Black Paint Off White(3)(9) Off White Chrome Dull Chrome Dull Lead Plated(3)(4)(8) Wax Coated(3)(4)(5)(8) Wax Over Lead(3)(4)(5)(3) (1) Other colors and finishes are available on special order. Consult factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. (2) 200°F (93°C) maximum. (3) UL and ULC listed only. (4)155°F to 200°F (68°C to 93°C) ratings only. (5) 286°F (141 °C) sprinklers may be coated for ambient conditions not exceeding 150°F (66°C). (6) cULus listed "corrosion resistant' applies to SIN Number RA1325 (Upright) RA1323 (upright), RA1321(Upright), RA1335 (HSW), RA1385(VSW) and RA1314 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (') FM Approved finish as "Polyester Coated" applies to SIN number RA1314, RA1335 & RA1325 in standard black or white. (8) FM Approved finish applies only to SIN number RA1335 & RA1385. (9) LPCB and VdS Approved finish applies only to RA1325, RA1314 and RA1375. (10) cULus listed Corrosion Resistant applies to SIN RA1325 ,RA1314 ,RA1323, RA1313 ,RA1321, RA1311, RA1385 and RA1335 5. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled ® (800) 431-1588 Sales Offices Paper iab e () 8-051 Sales Fax (914914) 82929-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 03/17 P/N 9999970299 Bulletin 016 September 2021 Reliable For coverages up to 28 feet wide and 10 feet long'). 250 psi (17,2 bar) rated. Features: 1. Coverage for long and narrow spaces such as hallways, corridors, decks and rooms up to 28 feet wide and 10 feet long (see figure 1). 2. Deflector to ceiling dimensions are: 4" (102mm) min. to 12" (305mm) max. 3. Minimum spacing between sprinklers 16 feet (4.9m).0) 4. White polyester, black plyester, and ENT finish sprinklers are cULus Listed as Corrosion Resistant (not applicable to concealed sprinklers). 5. 5.6 K Factor. 6. Sprinkler is approved for 250 psi (17,2 bar) applications. 8. Quick response performance. 9. '/2" (13mm) adjustment of escutcheon and cover. 10.Concealed cover plate can prevent the sprinkler from being used for unintended purposes. No exposed thermal element with the concealed version. 11.Push-on/thread-off sturdy convenient escutcheon for recessed and cover for concealed. 12. Factory assembled sprinkler & cup, shipped complete with bulb protector for concealed and FP recessed versions. 13.Sprinkler & cup assembly and escutcheon or cover are separately packaged. 14.Available in a variety of plated and painted finishes Approval Organizations • Listed by Underwriters Laboratories Inc. and UL certified for Canada (cULus) Patents US Patent No. 7,841,418 Products Description The Model DH56 are quick response extended coverage sidewall dry sprinklers for use in light hazard applications. The Model DH56 dry sprinkler with SWC cover plate is a concealed sprinkler that uses Reliable's push on/thread off sidewall cover. This sprinkler has the cup factory mounted and is shipped with a bulb protector that protects the 3mm frangible glass bulb during shipping and post installation finishing operations. The DH56 can be combined in the field with the FP Escutcheon to make a recessed dry sprinkler. The SWC cover plate and FP recessed Model DH56 Dry (SIN RA1664) K5.6 (80 metric) Extended Coverage Horizontal Sidewall Sprinkler DH56 HSW DH56 HSW/HB M W i DH56 HSW FP Recessed with SWC cover plate escutcheons have'/2" adjustment. The SWC cover plate is attached with 135 & 165 degree solder. In the event of a fire the rising ambient temperature melts the solder and the cover plate is ejected away by springs exposing the 3mm frangible glass bulb. The use of a 3mm bulb allows quick response which enables the sprinkler to apply water to a fire sooner than standard response sprinklers of the same temperature rating. a Cn CD CD a- N CD Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model DH56 dry sprinklers are intended for use in wet, dry, and preaction systems to protect areas subjected to freezing temperatures and unheated portions inside and outside buildings. See Fig. 8 for guidelines on using dry sprinklers in wet systems. Environments wherein dry sprinklers are employed can be corrosive. For this reason, Model DH56 dry sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax will not interfere with the operation of the sprinkler, and it prevents contaminants from entering the internal portion of the drop nipple. The wax must not be removed. Application The Model DH56 is a horizontal sidewall dry sprinkler intended for installation in light hazard occupancies in accordance with NFPA 13. These sprinklers are designed to provide fire protection in long and narrow spaces such as hallways, corridors, decks and rooms up to 28 feet (8,5m) wide and 10 feet (3m) long. They are rated for 250 psi (17,2 bar) and can be mounted between 4 and 12 inches (102 and 305mm) down from the ceiling. --,,.16' [4.9m] Minimum Spacing 28' [8.5m] Maximum Spacing MODEL DH56 DRY SPRINKLER WALL \ � FLO 4" [100mm] min. From Ceiling 12" [305mm] max. From Ceiling 28' [8.5m] � 8' [2.4m] or 10' [3m] 016FG010 \\// Fig. 1 2. General Installation Instructions Reliable Model DH56 dry sidewall sprinklers may be installed in ductile or malleable cast iron threaded tees, or CPVC tees and adapters upon verification that the sprinkler inlet fitting does not interfere with the interior of the fitting (see Figure 9). DO NOT install Reliable Model DH56 dry sidewall sprinklers into elbows or couplings, welded outlets, mechanical tees, or gasket sealed CPVC fittings. Dry sprinklers connected to wet pipe systems must be installed as indicated in Figure 8 and as required by NFPA 13 with the Exposed Minimum Barrel Length located in a heated area. DH56 HSW Standard Escutcheon To install the DH56 HSW dry sprinkler cut a 21/8" diameter hole in the wall as shown in Fig. 4. Use the Model F3R installation wrench (see Fig. 3) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting'. Apply a PTFE based sealant to the sprinkler threads before installing in the sprinkler. Installation is completed by removing the orange glass bulb -protector and assembling the slip-on escutcheon to the sprinkler's can. DH56 HSW/HB Escutcheon To install the DH56 HSW/HB dry sprinkler cut a 2'/2" diameter hole in the wall as shown in Fig. 5. Use the Model F3R installation wrench (see Fig. 3) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting'. Apply a PTFE based sealant to the sprinkler threads before installing in the sprinkler. Installation is completed by removing the orange glass bulb -protector and assembling the slip-on escutcheon to the sprinkler's can. DH56 HSW FP Recessed Escutcheon To install the DH56 HSW dry sprinkler with the FP Escutcheon as a recessed sprinkler cut a 25/8" diameter hole in the wall as shown in Fig. 6. Temporarily remove the plastic protective cap, and then use the Model XL02 wrench' (see Fig. 2) to tighten the sprinkler until it is secured in the sprinkler fitting. Note: The Model XL02 wrench has a notch in it to accommodate the deflector top. This wrench can only be inserted one way. Care must be taken not to damage the deflector during tightening. Apply a PTFE based sealant to the sprinkler threads before installing in the sprinkler. It is recommended that the sprinkler be protected during plastering and painting operations by reinstalling the plastic protective cap. Installation is completed by removing the protective cap and inserting the push -on escutcheon. Turn clockwise to adjust the escutcheon against the wall. DH56 HSW SWC Concealed Cover Plate To install the DH56 HSW dry sprinkler with the SWC cover plate as a concealed sprinkler, cut a 21/8" diameter hole into the wall as shown in Fig. 7. Temporarily remove the plastic protective cap, and then use the Model XL02 wrench' (see Fig. 2) to tighten the sprinkler until it is secured in the sprinkler fitting. Note: The Model XL02 wrench has a notch in it to accommodate the deflector top. This wrench can only be inserted one way. Care must be taken not to damage the deflector during tightening. Apply a PTFE based sealant to the sprinkler threads before installing in the sprinkler. It is recommended that the sprinkler be protected during plastering and painting operations by reinstalling the plastic protective cap. Installation is completed by removing the protective cap and inserting the cover plate. Cover plate assemblies provide'/2" (13mm) of adjustment. Final adjustment is made by turning the cover plate clockwise until the skirt flange makes full contact with the wall surface. Cover removal requires turning in the counter -clockwise direction. Concealed cover plate assemblies are listed only for use with specific sprinklers. The use of any other concealed wall sprinkler or the use of the SWC cover plate on any sprinkler with which it is not specifically listed will void all guarantees, warranties, listings and approvals. Notes: 1. DH56 and DH56 Recessed Sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling, and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. 2. It is recommended that Reliable dry sprinklers be installed using the wrench referenced in this bulletin. A pipe wrench may also be used to install a dry sprinkler provided that it only engages the steel outer tube (pipe) of the assembly. Note that a pipe wrench will impart a large amount of torque into the final assembly. This torque will need to be matched or exceeded to remove the sprinkler at a later date. 3. Technical Data: K Factor Temperature Maximum Sprinkler Thread Size Rating Ambient Temperature Identification Number (SIN) US Met- Sprinkler SWC ric Cover 155°F 135°F 100°F (68°C) (57°C) (38°C) 175°F 165°F 150°F 5.6 80 1" RA1664 (79°C) (74°C) (66°C) 200°F 165°F 150°F (93°C) (74°C) (66°C) Coverage Area Maximum Coverage Flow Rate Pressure Area Width x Length gpm (L/min) psi (bar) IL ftxft(mxm) 28 x 8 (8,5 x 2,4) 23 (87,1) 16.9 (1,2) 28 x 10 8,5 x 3 28 106 25(1,7) Approval Type: • Quick Response, Extended Coverage. • Approved for installation in accordance with NFPA 13 for light hazard occupancies. Fig. 2 - F313 Wrench Maintenance Model DH56 Quick Response Dry Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in their original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. OMEW=-- I Step 1 10 Step 2 4=*WWj Step 3 Fig. 3 - XLO2 Wrench H Model DH56 Dry Sprinkler with Standard Escutcheon "A" Dim. 2" to 48" 51 mm to 1219mm in 1/4" 6mm increments for 1" connections System Tee /it n-- )i I Sprinkler Can nlet Fitting Ceiling 0 15/32" [12mm] 1 —15/ 1 6"" [53mm] -E 4" [102mm] Min. 12" [305mm] Max. 5/8" [16mm] 3" Dia. [76mm] 2-1 /8" Dia. [54mm] 1 /4" [6mm] Nominal Hole in Wall 11 Protrusion 1-1/4" [32mm] Escutcheon 076STD Adjustment "A" Dimensic Fig. 4 Finish Combinations: Standard Escutcheon Sprinkler Escutcheon(2)(3) Bronze Polished Stainless Steel Bronze Laquered Brass Chrome Polished Stainless Steel White Polyester(') White Polyester(4) Black Polyester(') Black Polyester(4) Custom Color Polyester(') Custom Color Polyester(4) Electroless Nickel PTFE(') Polished Stainless Steel 1 /4" [6mm] utcheon Adjustment Nominal Position of Escutcheon Notes: 1. UL Listed as Corrosion Resistant. 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is 316 stainless steel. 4. Base material may be brass. 5. Model DH56 Dry Sprinkler with HB Escutcheon 'W' Dim. 3-1/2" to 36" 89mm to 914mm in 1/4" 6mm increments for 1" connections Ceiling Escutcheon 4' [102 mm] Min. Sprinkler Can 12" [305 mm] Max. Inlet Fitting 1 —15/1 6"" System Tee [53mm] 5/8" [16 mm] n -+ — -- - — - — -- — 3-1/2„ nT— i [89 mm] Dia. 2 1/2" Dia. [64 mm] 1 —1 >/4 Hole in Wall 1-1/4" [32mm] [32mm] Nominal Projection 1/2" [13 mm] 016HB Escutcheon Adjustment ��:1/2" [13 Nominal Escutcheon Position Escutcheon Adjustment "A" Dimension — Finish Combinations: HB Escutcheon Sprinkler Escutcheon(2)(3) Bronze Chrome Chrome Chrome White Polyester(') White Polyester Black Polyester(') Black Polyester Custom Color Polyester)') Custom Color Polyester Electroless Nickel PTFEO) Stainless Steel Fig. 5 Notes: 1. UL Listed as Corrosion Resistant. 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is cold rolled steel unless noted. A Model DH56 Dry Sprinkler with FP Escutcheon "A" Dim. 3-1/2" to 48" 89mm to1219mm in 1/4" 6mm increments for 1" connections Ceiling Nom Escutcheon [32mm] Sprinkler Cup a 4" [102mm] Min. System Tee 12" [305mm] Max. Inlet Fitting 5/8„ [16mm] na 3 7/32 Dia. 2 5/8" Dia. [67mm] Hole in Wall 1/4" [6mm] Escutcheon Adjustment 1/4" [6mm] Nominal Position 016FP Escutcheon Adjustment of Escutcheon "A" Dimension Finish Combinations: FP Recessed Escutcheon SprinklerM Escutcheon(3)(4) Bronze Brass Chrome Chrome White Polyester(2) White Polyester Black Polyester(2) Black Polyester Custom Color Polyester(2) Custom Color Polyester Electroless Nickel PTFE(2) Stainless Steel Fig. 6 Notes: 1. Cup for FP Recessed is unfinished galvanized steel except electroless nickel PTFE sprinkler uses a stainless steel cup. 2. UL Listed as Corrosion Resistant. 3. Escutcheons do not carry corrosion resistant listings. 4. Base material is cold rolled steel unless noted. 7. Model DH56 Dry Sprinkler with SWC Cover Plate 'W' Dim. 3-1/2" to 48" 89mm W1219mm in 1/4" 6mm increments for 1" connections A 1-9116" [40mm] Sprinkler Cup 4" [102mmJ Min System Tee 12" [305mm] Max �Inlet Fitting 3-7/32" Dio. [82mm] i 2-518" [67mm] Dio. Hole in Wall 114" [6mm] Cover Plate Adjustment 1/4" [6mm] Cover Plate Adjustment Nominal Position o 16Swc of Cover Plate ';4" Dimension Finish Combinations: SWC Concealed Cover Plate SprinklerM Cover Plate(') Bronze White Polyester Chrome Bright Chrome Dull Bright Brass Unfinished Bronze Black Plate Custom Color Fig. 7 Notes: 1. Cup for SWC Concealed is unfinished galvanized steel. 2. Cover plates do not carry corrosion resistant listings. 13 MINIMUM EXPOSED BARREL LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER SYSTEM NOTE: STANDARD DRY PENDENT IS SHOWN, HOWEVER, MINIMUM EXPOSED BARREL LENGTH APPLIES TO ALL STYLES OF DRY SPRINKLERS CONNECTED TO A WET PIPE SYSTEM. WET PIPE AMBIENT TEMPERATURE EXPOSED TO DISCHARGE END OF SPRINKLER*(F EXPOSED BARREL AMBIENT TEMPERATURE 40'F/4'C I 50'F/10'C 60'F/16'C EXPOSED MINIMUM BARREL LENGTH** CE OF FITTING TO TOP OF CEILING)*** IN. (MM) IN. (MM) IN. (MM) 40-F (4'C) 0 0 0 30-F (-1'C) 0 0 0 20'F (-7'C) 4 (100) 0 0 10-F (-12'C) 8 (200) 1 (25) 0 07 (-18'C) 12 (300) 3 (75) 0 -10-F (-23'C) 14 (350) 4 (100) 1 (25) -207 (-29'C) 14 (350) 6 (150) 3 (75) -30-F (-34'C) 16 (400) 8 (200) 4 (100) -40'F (-40'C) 18 (450) 8 (200) 4 (100) -507 (-46'C) 20 (500) 10 (250) 6 (150) -60-F (-51'C) 20 (500) 10 (250) 6 (150) * FOR AMBIENT TEMPERATURES EXPOSED TO THE DISCHARGE END OF THE SPRINKLER THAT OCCUR BETWEEN THE VALUES LISTED, USE THE NEXT COOLER TEMPERATURE. ** THE MINIMUM EXPOSED BARREL LENGTH IS NOT THE SAME AS THE "A" DIMENSION. THE MINIMUM EXPOSED BARREL LENGTH IS BASED ON A PROPERLY SEALED PENETRATION WITH A MAXIMUM WIND VELOCITY ON THE EXPOSED SPRINKLER OF 30 MPH (48 KM/H). LONGER EXPOSED BARREL LENGTHS WILL HELP AVOID FREEZING OF THE WET PIPING WHERE HIGHER WIND VELOCITY IS EXPECTED. * THE MINIMUM EXPOSED BARREL LENGTH IS MEASURED FROM THE FACE OF THE FITTING TO THE INSIDE FACE OF THE INSULATION, WALL, OR CEILING LEADING TO THE COLD SPACE, WHICHEVER IS CLOSEST TO THE FITTING. SYSTEM PIPING MINIMUM EXPOSED BARREL LENGTH DECKTITE FLASHING (SEE ABOVE) RASCO #4003910 (RECOMMENDED) (PROTECTED AREA) \ f -----�- iiu NOTE: TEE MAY BE IN ANY ORIENTATION FOR WET PIPE II11II11IIII ��'�'I�tSYSTEMS. __� L__J IF HUMIDITY AND TEMPERATURE DIFFERENTIAL CAUSES CONDENSATION ON THE EXPOSED DRY SPRINKLER, CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION, FOAM INSULATING TAPE OR EQUIVALENT. MINIMUM (HEATED AREA) SEAL THE CLEARANCE SPACE EXPOSED AROUND THE SPRINKLER TO AVOID BARREL LEAKAGE OF AIR INTO THE PROTECTED LENGTH AREA AND CONSEQUENT FORMATION OF "A' CONDENSATE AROUND THE FRAME, WHICH DIMENSION CLEARANCE COULD INHIBIT OPERATION OR CAUSE HOLE PREMATURE OPERATION. SEE BELOW FOR RECOMMENDED METHODS. INSIDE SURFACE OF INSULATION, WALL, OR _ CEILING THERMAL ESCUTCHEON BARRIER i DISCHARGE END OF SPRINKLER PROTECTED (NON -CONDITIONED) AREA RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS (DRY SPRINKLER WITH STANDARD ESCUTCHEON SHOWN) -------- '_1 rt-----#--- r--1I9----i`u i; =---11�--� ---tLlk-! -f�-Dili- --4-- (HEATED AREA) INSIDE FACE (HEATED AREA) PIPING MINIMUM EXPOSED BARREL LENGTH (SEE ABOVE) DISCHARGE END OF DRY SPRINKLER IN COLD AREA COMDRYDET11 *CAUTION* RELIABLE DRY SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING, ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLER'S INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction; this will damage the sprinkler, the fitting, or both. Short inlet ("PL") versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations. Sprinklers with the short inlet ("PL") should only be installed in CPVC fittings of wet -pipe systems. In all cases, verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal Obstruction No Internal Obstruction � I Female Female Pipe Pipe Thread Thread CPVC Fitting with Internal Obstruction CPVC fitting - No Internal Obstruction l 1 1 Shorter Longer Inlet Inlet Male Male Pipe Pipe Thread Thread � ..7 Dry Sprinkler Dry Sprinkler Short Inlet ("PL") Standard Inlet BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION COMDRYDET12 Fig. 9 10. MATERIAL SPECIFICATIONS ITEM # DESCRIPTION MATERIAL SPECIFICATION 1 FRAME BRASS PER UNS C83600 2 DEFLECTOR BRONZE PER UNS C51000 3 LOAD SCREW BRASS PER UNS C22000 4 SEAT ADAPTOR BRASS ALLOY PER UNS C36000 5 BULB INSERT COPPER ALLOY PER UNS C31400 6 GLASS BULB GLASS W/GLYCERIN SOLUTION 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS C36000 8 OUTER TUBE GALVANIZED STEEL 9 INNER TUBE BRASS ALLOY PER UNS C23000 10 YOKE BRASS ALLOY PER UNS C38000 11 INLET BRASS ALLOY PER UNS C35330 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL PTFE COATED BERYLLIUM NICKEL 14 FLIP DISK BRASS ALLOY PER UNS C54400 15 CAN/ESCUTCHEON PAINTED OR PLATED MILD STEEL, EXCEPT FOR TYPE 316 STAINLESS STEEL FOR SPRINKLERS WITH ENT FINISH (OTHER THAN FP RECESSED) (PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) COMDRYDET13 ,PPEARANCE OF DEFLECTOR MAY VARY DEPENDING ON MODEL Fig. 11 11. Ordering Information Specify: 1. Sprinkler Type (select one): Model DH56 Dry EC HSW Model DH56 Dry EC HSW/HB Model DH56 Dry Recessed EC HSW/FP Model DH56 Dry Concealed EC HSW 2. Sprinkler Temperature Rating. 3. Sprinkler Finish. 4. Cover Plate/Escutcheon Finish. 5. Length: "A" Dimension (face of tee to face of ceiling or wall) in'/4" (6mm) increments. 6. Installation Wrenches: Model XL02 Sprinkler Wrench (Recessed & Concealed) Model F3R Sprinkler Wrench (Standard & HB) Notes: 1. The "A" dimension is based on a nominally gauged pipe thread "make-up" of 0.600" (15mm) per ANSI B2.1 [7'/2 threads approximately]. 2. All platings and paintings are decorative and intended for interior use. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years. Manufactured by Reliable Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address ® Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 09/21 P/N 9999970308 Bulletin 044 March 2022 Reliable Features • cULus Listed for areas of coverage up to 256 square feet • Sprinkler may be installed on the same branch line that supplies sprinklers below ceiling • Nominal K-factor of 5.6 (80 metric) • Fusible link operating element • Quick response 212°F (100°C) fusible link operating element • Standard brass finish Product Description Reliable's Model KFR-CCS Combustible Concealed Space Sprinkler is a quick response, upright, special sprinkler designed to provide protection of specific light hazard combustible and noncombustible concealed spaces requiring sprinkler protection. The KFR-CCS sprinkler is specifically listed for the protection of shallow combustible concealed spaces described in NFPA 13. The Model KFR-CCS Sprinkler utilizes a fast response solder - link fusible element that has demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This feature enables the sprinkler to apply water to a fire much faster than standard response sprinklers of the same temperature rating. Application The Model KFR-CCS sprinkler is specifically listed for use in horizontal combustible concealed spaces with a slope not exceeding 2:12 with combustible wood truss, wood joist construction, or bar joist construction having a combustible upper surface and where the depth of the space is less than 36" (914 mm) from deck to deck, from deck to ceiling, or with double wood joist construction with a maximum of 36" (914 mm) between the top of the bottom joist and the bottom of the upper joist. NFPA 13 permits the use of the Model KFR-CCS sprinkler (a) where the space is less than 12" (305 mm) from deck to deck or deck to ceiling, and/or (b) where a portion of the protected space exceeds 36" (914 mm). Installation Model KFR-CCS Sprinklers are to be installed in the upright position with their frames arms parallel to the pipe (Refer to Figs. 4 through 9). When installing the Model KFR-CCS sprinkler use only the Reliable Model W2 installation wrench. Usage of any other type of installation wrench may damage the sprinkler and will immediately void the manufacture's warranty. Note: A leak tight'/z" NPT (R1/2) sprinkler joint can be obtained with an installation torque of approximately 8 -18 ft-lbs (10.8 — 24.4 N-m). Do not tighten sprinklers over these recommended limits. Doing so may cause leakage and/or premature operation. Model KFR-CCS Combustible Concealed Space Sprinkler Model W2 Wrench Maintenance cULus Listed Model KFR-CCS Sprinklers should be inspected and maintained in accordance with the applicable version of NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using compressed air or by vacuuming, provided equipment does not touch the sprinkler. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Guarantee For Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Ordering Information Specify: Model KFR-CCS Sprinkler www.reliablesprinkler.com Finish Technical Specifications Standard Brass Style: Upright Threads: 112" NPT or IS07-1 R1/2 Temperature Ratings Nominal K-Factor: 5.6 (80 metric) 212°F (100-C) Max. Working Pressure: 175 psi (12 bar) Sensitivity Material Specifications Fast Response Thermal Sensor: Nickel Alloy Sprinkler Frame: Brass Alloy Sprinkler Wrench Button: Copper Alloy Model W2 Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Approvals Deflector: Bronze Alloy cULus Listed Model KFR-CCS Components and Installation Dimensions NH FAS FAE IMENSIONS D Minimum Distance (Spacing) Between Sprinklers 6'(1.83m) Note: This minimum spacing does not apply to any additional sprinklers that are required for protection of CPVC piping that is offset over an obstruction (refer to figures 4 and 5). Maximum Distance (Spacing) Between Sprinklers 14' (4.27 m) for solid wood and composite wood joist construction. For wood truss or bar joist construction, 14' (4.27 m) for concealed spaces that are less than 18" (457 mm) in depth; 16' (4.88 m) for concealed spaces that are 18" (457 mm) or more in depth. Maximum Coverage Area Per Sprinkler 196 ft2 (18.2 m2) for solid wood or composite wood joist construction. For wood truss or bar joist construction, 196 ft2 (18.2 m2) for concealed spaces that are less than 18" (457 mm) in depth; 256 ft2 (23.8 m2) for concealed spaces that are 18" (457 mm) or more in depth. Note: Sprinkler spacing, and therefore coverage area, is determined by the depth of the concealed space. When transitions occur in the concealed space, the sprinklers may immediately be spaced at the largest approved coverage area per the above listings for the concealed space depth (refer to Fig. 2). Obstruction Rules All obstruction criteria per the applicable version of the NFPA 13 apply unless modified by this bulletin (refer to Fig. 3). The KFR-CCS is classified as an Extended Coverage Upright Spray Sprinkler where the maximum coverage area per sprinkler exceeds 225 ft2 (20.9 m2). The KFR-CCS is classified as a Standard Upright Spray Sprinkler where the maximum coverage area per sprinkler is 225 ft2 (20.9 m2) or less. Bulletin 044 Reliably Page 2 of 9 March 2022 www.reliablesprinkler.com Model KFR-CCS Sprinkler Spacing at Change in Concealed Space Depth 7 LESS THAN 18" [457mm] KFR—CCS MAXIMUM SPACING MAXIMUM SPACING 14'X 14[4.3 m X 4.3 m] �/� �- ��� 16'X 16'[4.9 m X 4.9 m] 01f01A 196 SF [18.2 m'] 256 SF [23.8 m'] Note 1: For sloping concealed spaces, break point between sprinkler spacings is the point where the depth of the space equals 18" [457 mm]. 18" [457 mm] OR GREATER Bulletin 044 ReliablEc Page 3 of 9 March 2022 www.reliablesprinkler.com Bulletin 044 ReliablE� Page 4 of 9 March 2022 www.reliablesprinkler.com When used with CPVC piping, the Model KFR-CCS Sprinkler is specifically listed to provide protection of combustible concealed spaces where the construction methods consist of: 1. Wood trusses or wood bar joist (Refer to Fig. 4) 2. Noncombustible insulation -filled solid wood or composite wood joists* (Refer to Fig. 5) *Note: In order to be considered "noncombustible insula- tion -filled, solid wood or composite wood joists" construction, the insulation (including insulation provided with a combustible vapor barrier), must completely fill the pockets between the joists to the bottom of the joists. Insulation installed above the elevation of Model KFR-CCS sprinklers in wood truss, solid wood joist or composite wood joist must be secured into place with metal wire netting. The metal wire netting is intended to hold the insulation in place should the insulation become wet by the operation of Model KFR-CCS Sprinklers in the event of a fire. In order to use the CPVC pipe and fittings, the horizontal runs of pipe must be a maximum of 6 in. (152 mm) above the ceiling or noncombustible ceiling insulation, or 1/3 the depth of concealed space (as measured from the top surface of the ceiling to the bottom of the deck above), whichever is smaller (Refer to Figs. 4 & 5). The CPVC piping can be used to supply the Model KFR-CCS Sprinklers as well as sprinklers installed below the ceiling. Unless modified by this technical data sheet, all guidelines provided by the CPVC pipe and fitting manufacturer must be followed. When using 1 in. (DN25) or larger pipe, a hanger must be located at the truss nearest a sprig for purposes of restraint. If using 3/4 in. (DN19) piping, all sprigs over 12 in. (305 mm) must be laterally braced using methods described in the NFPA standards. Where the CPVC must be offset up and over an obstruction and the pipe exceeds the allowed horizontal positioning requirements specified above as well as shown in Figs. 4 and 5, additional Mod- el KFR-CCS Sprinklers are to be installed to protect the CPVC products. A minimum lateral distance of 18 in. (457 mm) must be maintained between the CPVC pipe and heat pumps, fan motors, and heat lamps. Concealed Space Area The area of the concealed space is not limited; however, for both Figs. 4 and Fig. 5 where CPVC pipe is being utilized, draft -cur- tains or full height walls must be provided at 1,000 ft2 (93 m2) maximum areas. This draft curtain shall be at least 1/3 the depth of the concealed space or 8 in. (203 mm), whichever is greater, and be constructed using a material that will not allow heat to escape through or above the draft curtain. System Type Light hazard, wet pipe system. Minimum Distance Away From Face of Wood Truss or Top Chord of Bar Joist 4.5 in. (114 mm) (Refer to Fig. 3) Deflector Position At or below the bottom of the top chord; 1.5 in. (38 mm) minimum to 4 in. (102mm) maximum below upper deck (or insulation if present) for wood truss construction or wood bar joist construc- tion (Fig. 4). 1.5 in. (38 mm) minimum to 4 in. (102mm) maximum below bottom of insulation for noncombustible insulation -filled solid or composite joist construction (Fig. 5). Hydraulic Design Area Calculate all sprinklers within the draft curtain area, up to the 1,000 ft2 (93 m2) maximum draft curtain area. Note: Additional sprinklers that are required for protection of CPVC piping that is offset over an obstruction do not need to be included in the remote area. Required Density 0.10 gpm/ft2 (4.08 Lpm/m2) Minimum Operating Pressure 7 psi (0.48 bar) Bulletin 044 March 2022 Page 5 of 9 www.reliablesprinkler.com Model KFR-CCS CPVC Pipe CPVC PIPE CONSTRUCTION: WOOD TRUSS OR WOOD BAR JOIST TOP CHORD DEPTH 4" �(100 mm) OR LESS oaaFcaa_os SEE NOTE 1 i SEE NOTE 2 I KFR—CCS SPRINKLERS TO BE I I INSTALLED WITH FRAME ARMS IN —LINE (PARALLEL) WITH PIPE. L — J I PIPE SHALL BE LOCATED A MAXIMUM OF 6" ABOVE THE TOP OF THE CEILING (OR INSULATION), OR A MAXIMUM OF ONE—THIRD (1/3) THE DEPTH OF THE CONCEALED SPACE ABOVE THE TOP OF THE CEILING, WHICHEVER IS SMALLER. Model KFR-CCS CPVC Pipe 044rG04_09 4-1/2" [114mm] MINIMUM FROM CENTERLINE OF SPRINKLER TO FACE OF WOOD TRUSS OR UPPER TOP CHORD OF BAR JOIST DECK MAXIMUM 6" [152mm] ............... .OBSTRUCFION.�.� WHEN OFFSETTING CPVC PIPE OVER OBSTRUCTION, A KFR—CCS SPRINKLER MUST BE INSTALLED DIRECTLY ON THE PIPE OVER THE OBSTRUCTION. Note 1: Deflector at or below bottom of top chord; 1-1/2" (38 mm) minimum to 4" (102 mm) maximum below bottom of roof deck or insulation. Note 2: Distance evaluated as part of cULus Listing: 12" to 36" (305 to 914 mm). NFPA 13 permits the installation of these sprinklers in combustible concealed spaces where (a) the distance from deck to deck or deck to ceiling is less than 12" (305 mm) and/or (b) a portion of the protected area exceeds a depth of 36" (914 mm). UPPER DECK SEE NOTE 3 SEE NOTE 2 CPVC PIPE CONSTRUCTION: NONCOMBUSTIBLE INSULATION —FILLED SOLID WOOD OR COMPOSITE WOOD JOIST NONCOMBUSTIBLE SOLID WOOD COMPOSITE WOOD INSULATION JOISTS JOISTS SEE NOTE 1 J I KFR—CCS SPRINKLERS TO BE INSTALLED WITH FRAME ARMS IN —LINE (PARALLEL) WITH PIPE. ---------- PIPE SHALL BE LOCATED A MAXIMUM OF 6" ABOVE THE TOP OF THE CEILING (OR INSULATION), OR A MAXIMUM OF ONE—THIRD (1/3) THE DEPTH OF THE CONCEALED SPACE ABOVE THE TOP OF THE CEILING, WHICHEVER IS SMALLER. T\\\T\\\� MAXIMUM 6" [152mm] WHEN OFFSETTING CPVC PIPE OVER OBSTRUCTION, A KFR—CCS SPRINKLER MUST BE INSTALLED DIRECTLY ON THE PIPE OVER THE OBSTRUCTION. Note 1: Deflector distance below bottom of joist/insulation to be 1-1/2" to 4" (38 mm to 102 mm). Note 2: Distance evaluated as part of cULus Listing: 6" to 36" (152 to 914 mm). NFPA 13 permits the installation of these sprinklers in combustible concealed spaces where a portion of the protected area exceeds a depth of 36" (914 mm). Note 3: Maximum distance evaluated as part of cULus Listing: 60" (1524 mm). Bulletin 044 ReliablE� Page 6 of 9 March 2022 www.reliablesprinkler.com When used with steel piping, the Model KFR-CCS Sprinkler is specifically listed to provide protection of combustible concealed areas where the construction methods consist of: 1. Wood trusses or wood bar joists (Refer to Fig. 6) 2. Solid wood joist construction where the upper ceiling joists may have a maximum depth of 12 in. (305 mm). (Refer to Fig. 7). 3. Noncombustible insulation -filled, solid wood or composite wood joists* (Refer to Fig. 9) 4. Obstructed wood trusses; top chord more than 4" deep (Refer to Fig. 8). *Note: In order to be considered "noncombustible insulation - filled, solid wood or composite wood joists" construction, the insulation (including insulation provided with a combustible vapor barrier), must completely fill the pockets between the joists to the bottom of the joists. Insulation installed above the elevation of Model KFR-CCS sprinklers in wood truss, solid wood joist or composite wood joist must be secured into place with metal wire netting. The metal wire netting is intended to hold the insulation in place should the insulation become wet by the operation of Model KFR-CCS Sprinklers in the event of a fire. Concealed Space Area The area of the concealed space is not limited; however, for wood truss construction or concealed spaces of noncombustible bar joist construction (Refer to Fig. 6) draft -curtains or full height walls must be provided at 1,000 ft2 (93 m2) areas. The draft curtain shall be at least 1/3 the depth of the concealed space or 8 in. (203 mm), whichever is greater, and be constructed using a material that will not allow heat to escape through or above the draft curtain. For solid wood joist construction (Refer to Fig. 7) and obstructed wood truss construction (Refer to Fig. 8), blocking must be provided in each joist or top chord channel at maximum 32 ft. (9.75 m) intervals. This blocking shall be installed to the full depth of the joist or top chord and be installed so as to not allow heat to escape through or above the blocking. The blocking must be constructed using a noncombustible material or be of the same material as the joist or truss member. Draft curtains must be protrude below the joist a minimum of 6 in. (152 mm) or 1/3 the space, whichever is greatest and run parallel with the joist spaced at 31 ft. (9.45 m) width maximum to limit the area to a maximum of 1,000 ft2 (93 m2). The draft curtain may be constructed of in. (6.4 m) plywood to prevent heat from escaping beyond the area. For noncombustible insulation -filled, solid wood joist or composite wood joist construction (Refer to Fig. 9), the requirement for draft curtains or blocking does not apply. System Type Light hazard, wet or dry pipe system. Deflector Position At or below the bottom of the top chord; 1.5 in. (38 mm) minimum to 4 in. (102mm) maximum below upper deck (or insulation if present) for wood truss construction or wood bar joist construction (Fig. 6). 1.5 in. (38 mm) minimum to 2 in. (51 mm) maximum below the bottom of the top chord for spaces constructed of obstructed wood trusses (Fig. 8). 1.5 in. (38 mm) minimum to 2 in. (51 mm) maximum below the bottom of the upper joist for concealed spaces constructed of exposed solid wood joists (Fig 7). 1.5 in. (38 mm) minimum to 4 in. (102mm) maximum below bottom of insulation for noncombustible insulation -filled solid or composite joist construction (Fig. 9). Minimum Distance Away From Face of Wood Truss or Top Chord of Bar Joist 4.5 in. (114 mm) (Refer to Fig. 4) Hydraulic Design Area For wood truss construction (Fig. 6), solid wood joist construction (Fig. 7), or obstructed wood truss construction (Fig. 8), calculate all sprinklers within the draft curtain area, up to the 1,000 ft2 (93 m2) maximum draft curtain area for both wet and dry pipe systems. For noncombustible insulation -filled solid wood joist or composite wood joist construction (Fig. 9) where draft curtains are not required, calculate per the requirements of NFPA 13. Required Density 0.10 gpm/ft2 (4.08 Lpm/m2) Minimum Operating Pressure 7 psi (0.48 bar) Bulletin 044 March 2022 Page 7 of 9 www.reliablesprinkler.com Model KFR-CCS Steel Pipe STEEL PIPE CONSTRUCTION: WOOD TRUSS OR WOOD BAR JOIST (TOP CHORD 4" OR LESS IN DEPTH) 044vc04_09 FROM FACE OF WOOD TRUSS OR TOP WOOD TRUSS OF CHORD OF BAR JOIST �OR BAR JOIST 4.5' [114mm] MINIMUM DISTANCE UPPER DECK SEE NOTE 2 Model KFR-CCS Steel Pipe C SEE NOTE 2 FOR MAXIMUM DISTANCE SEE NOTE 1 FOR MINIMUM AND MAXIMUM DISTANCE 1 SEE NOTE 1 r KFR—CCS SPRINKLERS TO BE INSTALLED WITH FRAME ARMS IN —LINE (PARALLEL) WITH PIPE. LOCATION OF STEEL PIPE IN CONCEALED SPACE IS NOT RESTRICTED Note 1: Deflector at or below the bottom of the top chord; 1-1/2" (38 mm) to 4" (102 mm) below bottom of roof deck or insulation. Note 2: Distance evaluated as part of cULus Listing: 12" to 36" (305 to 914 mm). NFPA 13 permits the installation of these sprinklers in combustible concealed spaces where (a) the distance from deck to deck or deck to ceiling is less than 12" (305 mm) and/or (b) a portion of the protected area exceeds a depth of 36" (914 mm). STEEL PIPE CONSTRUCTION: SOLID WOOD JOIST 2X FLOOR JOISTS SOLID WOOD 16" [406mm] ON CENTER CEILING FRAMING KFR—CCS SPRINKLER Ir ALL SPRINKLERS TO BE INSTALLED WITH FRAME ARMS IN —LINE WITH THE RUN OF THE PIPE. (PARALLEL) L— — — — — — — — — — J Note 1: Minimum to Maximum Distance evaluated as part of cULus Listing: 6" to 36" (152 to 914 mm). NFPA 13 also permits the installation of these sprinklers in combustible concealed spaces where (1) the distance from deck to deck or deck to ceiling is less than 12" (305 man) or (2) a portion of the protected area exceeds a depth of 36" (914 mm). Note 2: Maximum Distance evaluated as part of cULus Listing: 54" (1372 mm). NFPA 13 also permits the installation of these sprinklers in combustible concealed spaces where (1) the distance from deck to deck or deck to ceiling is less than 12" (305 mm) or (2) a portion of the protected area exceeds a depth of 36" (914 mm). UPPER DECK 12" MAXIMUM [305mm] MINIMUM DISTANCE 1.5" [38mm] MAXIMUM DISTANCE 2" [51mm] CEILING Bulletin 044 Reliable Page 8 of 9 March 2022 www.reliablesprinkler.com Model KFR-CCS Steel Pipe STEEL_ PIPE CONSTRUCTION: OBSTRUCTED WOOD TRUSS OR BAR JOIST (TOP CHORD MORE THAN 4 IN. DEPTH) 044FG04_09 WOOD TRUSS OR BAR JOIST i i SEE NOTE 3 SEE NOTE 2 r KFR—CCS SPRINKLERS TO BE INSTALLED WITH FRAME ARMS INSTALLED (PARALLEL) WITH PIPE. — — — — — — — — — LHH LOCATION OF STEEL PIPE IN CONCEALED SPACE IS NO T RESTRICTED UPPER DECK Note 1: Deflector distance below bottom of joist to be 1-1/2" to 2" (38 mm to 51 mm). Note 2: Distance evaluated as part of cULus Listing: 6" to 36" (152 to 914 mm). NFPA 13 also permits the installation of these sprinklers in combustible concealed spaces where a portion of the protected area exceeds a depth of 36" (914 men). Note 3: Maximum distance evaluated as part of cULus Listing: 60" (1524 mm). Model KFR-CCS Steel Pipe STEEL PIPE CONSTRUCTION: NONCOMBUSTIBLE INSULATION —FILLED SOLID WOOD OR COMPOSITE WOOD JOIST CEILING SEE NOTE 1 044FO04_09 NONCOMBUSTIBLE SOLID WOOD COMPOSITE WOOD UPPER INSULATION JOISTS JOISTS DECK SEE NOTE 3 SEE NOTE 2 SEE NOTE 1 \r KFR—CCS SIPRINKLERSTO BE , LOCATION OF STEEL INSTALLED WITH FRAME ARMS 1 PIPE IN CONCEALED I IN —LINE (PARALLEL) WITH PIPE. I SPACE IS NOT RESTRICTED — CEILING a WA Note 1: Deflector distance below bottom of joist/insulation to be 1-1/2" to 4" (38 mm to 102 mm). 7 O Note 2: Distance evaluated as part of cULus Listing: 6" to 36" (152 to 914 mm). NFPA 13 permits the installation of these sprinklers in combustible concealed spaces where a portion of the protected area exceeds a depth of 36" (914 mm). Note 3: Maximum distance evaluated as part of cULus Listing: 60" (1524 mm). 0') Z d Bulletin 044 Reliable Page 9 of 9 March 2022 www.reliablesprinkler.com Reliable Horizontal (See with Model F3QR56 Dry sprinklers will void all guarantees, warranties, listings and approvals. Inlet fittings are available with 1" NPT, ISO 7-1 R1, 3/4" NPT, or IS07-1 R3/4 threads. Sprinklers with 3/4" NPT and ISO7- 1 R3/4 inlet fittings are intended primarily for replacement of existing 3/4" or IS07-1 R3/4 inlet dry sprinklers, but may also be used in new installations. See the Available Configurations, Listings, and Approvals table in this Bulletin for further information on Model F3QR56 Dry sprinklers. Available Configurations, Listings, and Approvals Sprinkler Sprinkler Escutcheon or Available Listings and Inlet Identification Model Cover Plate Length Approvals(') Threads Number (See Figs. 1-9) (SIN) Standard 2" to 36" Escutcheon (50 to 900 mm) HB Extended Escutcheon cULus, NYC 3/4" NPT or F1 Recessed Escutcheon 3-1/2" to 36" IS07-1 R3/4 (90 to 900 mm) FP Recessed Escutcheon CCP Cover Plate F3QR56 Dry Pendent Standard 2" to 48" R5714 Escutcheon (50 to 1200 mm) HB Extended Escutcheon 1" NPT F1 Recessed cULus, FM, NYC or Escutcheon Escutcheon 3-1/2" to 48" R1 (90 to 1200 mm) FP Recessed Escutcheon CCP Cover Plate Standard 2" to 48" Escutcheon (50 to 1200 mm) HB Extended Escutcheon cULus(2), NYC(2) 3/4" NPT 3-1/2" to 48" or IS07-1 R3/4 F1 Recessed Escutcheon (90 to 1200 mm) FP Recessed F F3QR56 Dry Escutcheon Horizontal Sidewall Standard 2" to 48" cULus(2), R5734 Escutcheon (50 to 1200 mm) FM(3), NYC(2) HB Extended 3-1/2" to 48" Escutcheon (90 to 1200 mm)or 1" NPT 7-1 R1 IS07- F1 Recessed Escutcheon 3-1/2" to 48" cULus(2), FP Recessed (90 to 1200 mm) FM(3)(4), NYC(2) Escutcheon F3QR56 Dry N/A 5" to 48" cULus(2) 1" NPT or R5724 Upright (127 to 1200 mm) IS07-1 R1 0) For available temperature ratings and finishes see the Temperature Ratings and Finishes tables, respectively, in this Bulletin. (2) cULus Listing and NYC for Light Hazard and Ordinary Hazard only. (3) FM Approved for Light Hazard only. (4) Model F3QR56 Dry Horizontal Sidewall with Model F1 or Model FP recessed escutcheon are FM Approved as Standard Response. 2. Listing and Approval Agencies See the Available Configurations, Listings, and Approvals table in this Bulletin for listings and approvals applicable to each available configuration. 1. Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) 2. Certified by FM Approvals (FM) 3. Permitted in New York City based on UL Listing per Local Law 33/2007 (NYC) Technical Data Nominal K-Factor: 5.6 gpm/psi112 (80 L/min/bar'/2) Sprinkler Listing or Approval Deflector to Ceiling Distance Maximum Working Pressure F3QR56 Dry Pendent cULus, NYC See note below 250 psi (17.2 bar) FM See note below 175 psi (12 bar) F3QR56 Dry Horizontal Sidewall cULus, NYC 4" to 6 " 250 psi (17.2 bar) 4" to 12" 175 psi (12 bar) FM See note below 175 psi (12 bar) F3QR56 Dry Upright cULus See note below 175 psi (12 bar) Note: Deflector distance to be in accordance with applicable NFPA, FM, or other agency requirements. Information is provided only when additional clarification is necessary. Temperature Classification Glass Bulb Color Sprinkler Temperature Rating Cover Plate Temperature Rating Maximum Ceil- ing Temperature Listings and Approvals(') Ordinary Orange 135°F(57°C) 135°F (57°C) 100°F (38°C) cULus, FM, NYC Red 155°F(68°C) Intermediate Yellow 175°F (79°C) 165°F (74°C) 150°F (66°C) cULus, NYC Intermediate Green 200°F (93°C) 165°F (74°C) 150°F (66°C) cULus, FM, NYC High Blue 286°F(141°C) None 225°F (107°C) cULus, FM(2), NYC 165°F (74°C) 150°F (66°C) cULus, NYC (') For listed and approved sprinkler, escutcheon, and inlet configurations see the Available Configurations, Listings, and Approvals table in this Bulletin. (2) High temperature classification is FM Approved with Standard and Model HB escutcheons only. Finishes¢ Component Sprinkler Escutcheon') Cover Plate Standard Finishes Bronze Brass(3) White Paint White Polyester (2) White Polyester Chrome Chrome Chrome Special Application Finishes Electroless Nickel PTFE(2) Type 316 Stainless Steel Satin Chrome Black Paint Custom Color Paint Black Plating Black Polyester (2) Black Polyester Custom Color Polyester Customer Color Polyester M Standard and Model HB escutcheons are supplied with both the can and escutcheon finished. Model F1 escutcheons are supplied with both the collar and escutcheon finished. Model FP escutcheons are supplied with the escutcheon finished; the cup is galvanized or stainless steel with no further finish. (2) cULus Listed as a Corrosion Resistant Sprinkler. (3) Brass finish available for standard, Model F1, and Model FP escutcheons only. (4) Dry upright sprinkler available in standard bronze only. 3. Model F301356 Dry Pendent Sprinkler with Standard Escutcheon (SIN R5714) "A" Dim. ?» to 48„ (51mm to 1219mm) in 1/4" (6mm) increments for 1" connections or "A" Dimension [5, HOIE 1-1 /4" [32 mm] Escutcheon Adjustment Nominal Escutcheon Position 1/4" [6 mm] Escutcheon Adjustment 1/4" [6 mi Nominal Protrus1-11 Fig. 1 3" [76 mm] DIA. m Fitting itting ;r Can ,on 15/32" J- [12mm] 8" m] COMDRYDET1 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides 1/4" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. Sprinkler Guard: Model C2 9 Model F301356 Dry Pendent Sprinkler with Model HB Extended Escutcheon (SIN R5714) "A" Dim. 3Y2„ to 48„ (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or "A" Dimension 2-1 /2" [F I Dia. Hole ii 1/2" [13mm Escutcheon Adjus Nome nal Position of Escutcheon 1 /2" [13mm] Escutcheon Adjustment COMDRY1 Fig. 2 tscuicneon Dia. tee tting atcheon iklen Can Note: The sprinkler can protrudes 11/4" when escutcheon is in nominal position. Escutcheon adjustment provides '/2" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. Sprinkler Guard: Model C2 5. Model F301356 Dry Pendent Sprinkler with Model FP Recessed Escutcheon (SIN R5714) "A" Dim. 31h° to 48„ (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or � r ------ ---— _------7^--- — -- I�ti----'T � iliil I I I I�iii q �1 J r I&' L --� System Tee 2-5/8" [67 mm] Dia. "A" Dimension Hole in Ceiling 1/4" [6 mm] Escutcheon Adjustment 1 Ceiling I Inlet Fitting Sprinkler Cup Escutcheon 1 fI 3/4" [19 mm] Nom. Nominal Escutcheon Position 3-7/32" 1/4" [6 mm] Escutcheon Adjustment [82 mm] Dia. COMDRYDET3 Fig. 3 Note: Do not install the Model F3QR56 Dry Pendent sprinkler with the Model FP escutcheon in ceilings which have positive pressure in the space above. 2 Model F3QR56 Dry Pendent Sprinkler with Model CCP Cover Plate (SIN R5714) "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or —IIII31/2" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections W Nominal C( Plate Position 3/16" [5 mm] Cover Plate Adjustment FZ----- sF ---- --- -- I 7 I i i i t I — Ik I Fig. 4 3-5/16" [84 mm] Dia. i Tee ng ,r Cup I CCP 1/2 Plate Assembly T 7/8" 22 mm] J COMDRYDET4 Note: Do not install the Model F3QR56 Dry Pendent sprinkler with the Model CCP cover plate in ceilings which have positive pressure in the space above. 7. Model F3011156 Dry Pendent Sprinkler with Model F1 Recessed Escutcheon (SIN R5714) "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 31/2" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" cornections. "A" Dimension 2-1/4" [57 mm] Dia. Hole in Ceiling 1/4" [6 mm] Escutcheon Adjustment 1 � Nominal Escutcheon Position 1/4" [6 mm] Escutcheon Adjustment Fig. 5 s -1 liii III I L--1�L===J - System Tee Inlet Fitting Collar 1/8" Ceiling �13 mm] ex I Escutcheon 2-27/32" [72 mm] Dia. COMDRYDET5 91 Model 17301356 Dry Horizontal Sidewall Sprinkler with Model HB Escutcheon (SIN R5734) "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 31/2" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections Ceiling LF m � I 4" [102mm] Min. Escutcheon 12" [305mm] Max. Sprinkler Can System Tee 2 3/32" Inlet Fitting [53mm] , 5/8" [16mm] 3-1/2" -- - - - - - - - - - - - - -� [89mm] Escutcheon Dia. 2 1/2" Dia. Hole 4n Wall 1-1/4" 1-1/4" [32mm] Nominal Protrusion [32mm] �-1/2" [13mm] Escutcheon Adjustment COMDRYDET7 1/2" [13mm] Nominal Position Escutcheon of Escutcheon Adjustment "A" Dimension Fig. 7 Note: The sprinkler can protrudes 11/4" when escutcheon is in nominal position. Escutcheon adjustment provides -1/2" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. 10. Model F301156 Dry Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon (SIN R5734) "A" Dim. 31/2' to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 31/2" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections Ceiling Nom. 1-1/4" Escutcheon [32 mm] 4" [102 mm] Min. Sprinkler Cup cULus, NYC: 6" [152 mm] Max. System Tee FM: 12" [305 mm] Max. Inlet Fitting Jvl� 3-7/32" [82 mm] Dia. 2-1/2" [64 mm] Dia. Hole in Wall COMDRYDET8 1/4" [6 mm] Escutcheon Adjustment "A" Dimension • 1/4" [6 mm] Escutcheon Adjustment Nominal Escutcheon Position Note: Do not install the Model F3QR56 Dry Horizontal Sidewall sprinkler with the Model FP escutcheon in walls which are positively pressurized with respect to the protected space. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon (SIN R5734) "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 31h" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections System Tee COMDRYDET9 Escutcheon Collar Inlet Fitting //— 2-1/4" [57 mm] Dia. Hole in Wall 1/4" [6 mm] Escutcheon Adjustment "A" Dimension Fig. 9 Ceiling Nom. 1-3/4" _ 1/8" [44 mm] [3 mm] 4" [102 mm] Min. cULus, NYC: 6" [152 mm] Max. FM: 12" [305 mm] Max. 5/8" [16 mm] 2-27/32" [72 mm] Dia. 1/4" [6 mm] Escutcheon Adjustment Nominal Position of Escutcheon 12. Model 17301156 Dry Upright (SIN 5724) Order Dimensions 5" to 48" (127 mm to 1219 mm) Note: Customer is responsible for determining correct deflector distance below structure above. Order Dimension Inlet Fitting System Tee r - - COMDRYDET10 J L- - - 7Will Ls-----T --ZJ I Fig. 10 13. MINIMUM EXPOSED BARREL LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER SYSTEM NOTE: STANDARD DRY PENDENT IS SHOWN, HOWEVER, MINIMUM EXPOSED BARREL LENGTH APPLIES TO ALL STYLES OF DRY SPRINKLERS CONNECTED TO A WET PIPE SYSTEM. WET PIPE AMBIENT TEMPERATURE EXPOSED TO DISCHARGE END OF SPRINKLER*(F EXPOSED BARREL AMBIENT TEMPERATURE 40'F/4'C 50'F/10'C 60'F/16'C EXPOSED MINIMUM BARREL LENGTH** CE OF FITTING TO TOP OF CEILING)*** IN. (MM) IN. (MM) IN. (MM) 40-F (4'C) 0 0 0 307 (-1'C) 0 0 0 20-F (-7'C) 4 (100) 0 0 10-F (-12'C) 8 (200) 1 (25) 0 07 (-18'C) 12 (300) 3 (75) 0 -10'F (-23'C) 14 (350) 4 (100) 1 (25) -20'F (-29'C) 14 (350) 6 (150) 3 (75) -30-F (-34'C) 16 (400) 8 (200) 4 (100) -40'F (-40'C) 18 (450) 8 (200) 4 (100) -50-F (-46'C) 20 (500) 10 (250) 6 (150) -60-F (-51'C) 20 (500) 10 (250) 6 (150) * FOR AMBIENT TEMPERATURES EXPOSED TO THE DISCHARGE END OF THE SPRINKLER THAT OCCUR BETWEEN THE VALUES LISTED, USE THE NEXT COOLER TEMPERATURE. ** THE MINIMUM EXPOSED BARREL LENGTH IS NOT THE SAME AS THE "A" DIMENSION. THE MINIMUM EXPOSED BARREL LENGTH IS BASED ON A PROPERLY SEALED PENETRATION WITH A MAXIMUM WIND VELOCITY ON THE EXPOSED SPRINKLER OF 30 MPH (48 KM/H). LONGER EXPOSED BARREL LENGTHS WILL HELP AVOID FREEZING OF THE WET PIPING WHERE HIGHER WIND VELOCITY IS EXPECTED. * THE MINIMUM EXPOSED BARREL LENGTH IS MEASURED FROM THE FACE OF THE FITTING TO THE INSIDE FACE OF THE INSULATION, WALL, OR CEILING LEADING TO THE COLD SPACE, WHICHEVER IS CLOSEST TO THE FITTING. WET IF HUMIDITY AND TEMPERATURE DIFFERENTIAL CAUSES CONDENSATION ON THE EXPOSED DRY SPRINKLER, CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION, FOAM INSULATING TAPE OR EQUIVALENT. MINIMUM (HEATED AREA) SEAL THE CLEARANCE SPACE EXPOSED AROUND THE SPRINKLER TO AVOID BARREL LEAKAGE OF AIR INTO THE PROTECTED LENGTH AREA AND CONSEQUENT FORMATION OF "A" CONDENSATE AROUND THE FRAME, WHICH OIMENSION CLEARANCE COULD INHIBIT OPERATION OR CAUSE HOLE PREMATURE OPERATION. SEE BELOW FOR RECOMMENDED METHODS. INSIDE SURFACE OF INSULATION, WALL, OR _ CEILING PROTECTED (NON -CONDITIONED) AREA) RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS (DRY SPRINKLER WITH STANDARD ESCUTCHEON SHOWN) ESCUTCHEON ISCHARGE END OF SPRINKLER WET PIPE (HEATED AREA) (HEATED AREA) MINIMUM MINIMUM EXPOSED EXPOSED BARREL BARREL LENGTH DECKTITE FLASHING (SEE ABOVE) RASCO /j4003910 INSIDE FACE SEAL LENGTH (SEE ABOVE) (RECOMMENDED) � � � .. .... ..... .......... .. .... CLEARANCE HOLE '. .... ..... INSULATED FREEZER, fli OR COOLER STRUCTURE --- ...: OR EXTERIOR FRAMING -... ..... .'.;.. :.:.:.'.'. (PROTECTED AREA) III CIF III -DISCHARGE END OF �``���`J'(J��DRY SPRINKLER N COLD AREA (PROTECTED AREA)W-DISCHARGE END OF DRY SPRINKLER IN COLD AREA COMDRYDETI *CAUTION* RELIABLE DRY SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING, ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLER'S INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction; this will damage the sprinkler, the fitting, or both. Short inlet ("PL") versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations. Sprinklers with the short inlet ("PL") should only be installed in CPVC fittings of wet -pipe systems. In all cases, verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal No Internal Obstruction Obstruction Female Female Pipe Pipe Thread Thread CPVC Fitting with Internal Obstruction CPVC Fitting - No Internal Obstruction 1 � Shorter Longer Inlet � Inlet Male Male Pipe Pipe Thread Thread -7I Dry Sprinkler Dry Sprinkler Short Inlet ("PL") Standard Inlet BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION COMDRYDET2 Fig. 12 15. Fig. 13 - Model F3R Wrench = i Ow Fig. 14 - Model XL02 Wrench 16. MATERIAL SPECIFICATIONS ITEM # DESCRIPTION MATERIAL SPECIFICATION 1 FRAME BRASS PER UNS C836W 2 DEFLECTOR BRONZE PER UNS 051000 3 LOAD SCREW BRASS PER UNS C22000 4 SEAT ADAPTOR BRASS ALLOY PER UNS C36000 5 BULB INSERT COPPER ALLOY PER UNS C31400 6 GLASS BULB GLASS W/GLYCERIN SOLUTION 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS C36000 8 OUTER TUBE GALVANIZED STEEL 9 INNER TUBE BRASS ALLOY PER UNS C23000 10 YOKE BRASS ALLOY PER UNS C38000 11 INLET BRASS ALLOY PER UNS C35330 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL PTFE COATED BERYLLIUM NICKEL 14 FLIP DISK BRASS ALLOY PER UNS C54400 15 CAN/ESCUTCHEON PAINTED OR PLATED MILD STEEL, EXCEPT FOR TYPE 316 STAINLESS STEEL FOR SPRINKLERS WITH ENT FINISH (PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) COMDRYDET13 ,PPEARANCE OF DEFLECTOR MAY VARY DEPENDING ON MODEL Fig. 15 17. Installation Instructions Model F3QR56 Dry sprinklers must only be installed in the following fittings: 1. The side outlet of an ANSI B 16.3 class 150 (malleable or ductile) or ANSI B16.4 class 125 (cast) iron pipe tee 2. The run outlet of an ANSI B 16.3 class 150 (malleable or ductile) or ANSI B16.4 class 125 (cast) iron pipe tee, with the side outlet plugged (wet -pipe systems only) 3. Spears Manufacturing Company Brass Thread In- sert Style or Special Reinforced Plastic Thread Style Listed adapter or tee (wet -pipe systems only) (gasket sealed outlets shall not be used) 4. Any Listed CPVC sprinkler adapter or tee only in ac- cordance with Fig. 12 and upon verification that the CPVC adapter or tee does not interfere with the sprin- kler's inlet (wet -pipe systems only) (gasket sealed outlets shall not be used) Model F3QR56 dry sprinklers must not be installed into el- bows, welded outlets, gasket sealed outlets, or couplings. Installation of the Model F3QR56 Dry sprinkler is not recom- mend in copper pipe systems, as this may reduce the life expectancy of the sprinkler. In all dry -pipe system installations, the Model F3QR56 Dry sprinkler must be installed with protrusion into the fitting in accordance with Fig. 1 through Fig. 10 in this Bulletin. Do not install Model F3QR56 Dry sprinklers with the standard (long) inlet fitting into CPVC fittings that have an internal obstruction (see Fig. 12); this will damage the sprinkler, the fitting, or both. Model F3QR56 Dry sprinklers are available with a short "PL" inlet fitting for installation on CPVC fittings of wet -pipe sprinkler systems only. Model F3QR56 Dry sprinklers connected to wet -pipe sys- tems must be installed with the Exposed Minimum Barrel Length required by Fig. 11 located in a Heated Area. An orange protective clip is factory installed on the sprin- kler to protect the glass bulb thermal element from dam- age. The clip should remain in place during installation of the sprinkler and be removed when the sprinkler system is placed in service. Sprinklers with 3/4" NPT and ISO7-1 R3/4 inlets are supplied with a protective cap on the inlet that must be removed before installation. Use the following steps for installation: 1. Cut a hole in the wall or ceiling directly in -line with the outlet of the fitting. See the Installation Data table for the recommended hole diameter based on the es- cutcheon or cover plate option selected. 2. Apply pipe joint compound or PTFE tape to the male threads of the sprinkler's inlet fitting. 3. Install the sprinkler in the fitting using the installation wrench specified in the Installation Data table. The Model F3R wrench is designed to be inserted into the groves in the sprinkler's wrench boss as shown in Fig. 13. The Model XLO2 wrench is designed to fit into the cup and engage the wrench boss as shown in Fig. 14. Do NOT wrench any part of the sprinkler assembly other than the wrench boss. When inserting or remov- ing the wrench from the sprinkler, care should be tak- en to prevent damage to the sprinkler. The sprinkler is then tightened into the pipe fitting to achieve a leak free connection. The recommended minimum to max- imum installation torque is 22 - 30 lb-ft (30 — 40 N-m) for 1" NPT and ISO7-1 R1 sprinklers, and 14 - 20 lb-ft (19 — 27 N-m) for 3/4" NPT and ISO7-1 R3/4 sprinklers. 3a.Alternatively, where access to the outer tube of the sprinkler is available, the Model F3QR56 Dry sprinkler may be installed using a pipe wrench. The pipe wrench shall only be permitted to inter- face with the galvanized steel outer tube portion of the sprinkler (Item #8 in Fig. 15). Do NOT wrench any other portion of the sprinkler assembly. A pipe wrench can install the sprinkler into the fitting with a large amount of torque; consideration should be given to the need for future removal of the sprin- kler because the installation torque will have to be matched or exceeded to remove the sprinkler. The recommended minimum to maximum installation torque is 22 - 30 lb-ft (30 — 40 N-m) for 1" NPT and ISO7-1 R1 sprinklers, and 14 - 20 lb-ft (19 — 27 N-m) for 3/4" NPT and ISO7-1 R3/4 sprinklers. 4. Standard and Model HB escutcheons can be in- stalled by slipping the escutcheon over the can until the escutcheon is seated against the ceiling or wall. Model F1 escutcheons are installed by pressing the escutcheon onto the collar until the escutcheon is seated against the ceiling or wall. The Model FP es- cutcheon is installed by pressing or threading the es- cutcheon into the cup by hand; the escutcheon can be tightened against the ceiling or wall by turning the escutcheon in a clockwise direction and removed by turning the escutcheon in a counter -clockwise direc- tion. To install the Model CCP cover plate, first remove the protective clip. Install the Model CCP cover plate on the sprinkler by pressing or threading the cover plate into the cup by hand; the cover plate can be tightened against the ceiling by turning the cover plate in a clockwise direction and removed by turning the cover plate in a counter -clockwise direction. 5. Remove the orange protective clip when placing the sprinkler system in service. Im Installation Data Sprinkler Suggested Hole Diameter Installation Required Centerline of Sprinkler Model Escutcheon or Cover Plate in Wall or Ceiling Wrench Tube/Inlet to Finished Ceiling Vertical Dimension* Standard Escutcheon 2-1/8" (54 mm) F3R HB Extended Escutcheon 2-1/2" (64 mm) F3R F3QR56 Dry Not F1 Recessed Escutcheon 2-1/4" (57 mm) XL02 Pendent Applicable FP Recessed Escutcheon XL02 2-1/2" (64 mm) CCP Cover Plate XL02 Standard Escutcheon 2-1/8" (54 mm) F3R 4-5/8" to 12-5/8" HB Extended Escutcheon 2-1/2" (64 mm) F3R (118 mm to 321 mm) F3QR56 Dry F1 Recessed Escutcheon 2-1/4" (57 mm) XL02 cULus, NYC Horizontal Sidewall 4-5/8"to /8" (118 mm to 6-56-5168 mm) FP Recessed Escutcheon 2-1/2" (64 mm) XL02 F1 Recessed Escutcheon 2-1/4" (57 mm) XL02 FM 4-5/8" to 12-5/8" FP Recessed Escutcheon 2-1/2" (64 mm) XL02 (118 mm to 321 mm) F3QR56 Dry N/A 1-1/2" (38mm) F3R Not Applicable Upright *Note: Based on 5/8" (16 mm) centerline of sprinkler tube/inlet to defector vertical distance. Maintenance The Model F3QR56 Dry Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sen- sitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by us- ing a soft brush or gently vacuuming. Replace any sprin- kler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or op- erated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Ordering Information Specify: 1. Sprinkler: [Model F3QR56 Dry Pendent SIN R5714] [Model F3QR56 Dry Horizontal Sidewall SIN R5734] [Model F2QR Dry Upright SIN R5724] 2. Escutcheon/Cover Plate: [None][Standard escutch- eon][Model HB extended escutcheon][Model F1 re- cessed escutcheon][Model FP recessed escutcheon] [Model CCP cover plate — pendent only] 3. Inlet Threads: [1" NPT][ISO7-1R1][3/4" NPT][IS07- 1 R3/4] 4. Inlet Fitting: [Long — Standard Inlet Fitting][Short "PL" — Wet Pipe Systems only] 5. Sprinkler Temperature Rating: See Temperature Rat- ings table 6. Sprinkler Finish: See Finishes Table 7. Escutcheon/Cover Plate Finish: See Finishes Table 8. Length: *For dry pendents and dry sidewalls: "A" Dimen- sion is from face of tee to face of finished ceiling or wall in 1/4" (6mm) increments. See Fig. 1 through Fig. 9. *For dry uprights: Order dimension is from face of tee to top of deflector in 1/4" (6mm) increments. See Fig. 10. Notes: 1. For Dry Upright, customer is responsible for determining the correct deflector distance from structure above. 2. Length is based on normally gauged pipe thread "make- up" of .600" (15mm) per ANSI B2.1 (approximately 7-1/2 threads). The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. ® Recycled ® (800) 431-1588 Sales Offices Paper Reliablla(914) 829-2051 Sales Fax848-2051 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 04/20 P/N 9999970175